https://arxiv.org/api/0ft55d/rmq7iukHBYDObKKfO+WY2026-06-26T05:16:28Z900899015http://arxiv.org/abs/2509.05071v1Systematic Review and Meta-analysis of AI-driven MRI Motion Artifact Detection and Correction2025-09-05T13:09:37ZBackground: To systematically review and perform a meta-analysis of artificial intelligence (AI)-driven methods for detecting and correcting magnetic resonance imaging (MRI) motion artifacts, assessing current developments, effectiveness, challenges, and future research directions. Methods: A comprehensive systematic review and meta-analysis were conducted, focusing on deep learning (DL) approaches, particularly generative models, for the detection and correction of MRI motion artifacts. Quantitative data were extracted regarding utilized datasets, DL architectures, and performance metrics. Results: DL, particularly generative models, show promise for reducing motion artifacts and improving image quality; however, limited generalizability, reliance on paired training data, and risk of visual distortions remain key challenges that motivate standardized datasets and reporting. Conclusions: AI-driven methods, particularly DL generative models, show significant potential for improving MRI image quality by effectively addressing motion artifacts. However, critical challenges must be addressed, including the need for comprehensive public datasets, standardized reporting protocols for artifact levels, and more advanced, adaptable DL techniques to reduce reliance on extensive paired datasets. Addressing these aspects could substantially enhance MRI diagnostic accuracy, reduce healthcare costs, and improve patient care outcomes.2025-09-05T13:09:37ZMojtaba SafariZach EidexRichard L. J. QiuMatthew GoetteTonghe WangXiaofeng Yang10.1016/j.ejmp.2025.105704http://arxiv.org/abs/2408.11885v2HDN: Hybrid Deep-Learning and Non-Line-of-Sight Reconstruction Framework for Transcranial Photoacoustic Imaging of Human Brain2025-09-05T05:37:25ZPhotoacoustic imaging combines the high contrast of optical imaging with the deep penetration depth of ultrasonic imaging, showing great potential in cerebrovascular disease detection. However, the ultrasonic wave suffers strong attenuation and multi-scattering when it passes through the skull tissue, resulting in the distortion of the collected photoacoustic signal. In this paper, inspired by the principles of deep learning and non-line-of-sight imaging, we propose an image reconstruction framework named HDN (Hybrid Deep-learning and Non-line-of-sight), which consists of the signal extraction part and difference utilization part. The signal extraction part is used to correct the distorted signal and reconstruct an initial image. The difference utilization part is used to make further use of the signal difference between the distorted signal and corrected signal, reconstructing the residual image between the initial image and the target image. The test results on a photoacoustic digital brain simulation dataset show that compared with the traditional method (delay-and-sum) and deep-learning-based method (UNet), the HDN achieved superior performance in both signal correction and image reconstruction. Specifically for the structural similarity index, the HDN reached 0.661 in imaging results, compared to 0.157 for the delay-and-sum method and 0.305 for the deep-learning-based method.2024-08-21T15:06:19Z8 pages, 8figuresPengcheng WanFan ZhangYuting ShenHulin ZhaoXiran CaiXiaohua FengFei Gao10.1109/TCI.2025.3594073http://arxiv.org/abs/2508.16897v2Generating Synthetic Contrast-Enhanced Chest CT Images from Non-Contrast Scans Using Slice-Consistent Brownian Bridge Diffusion Network2025-09-05T00:44:03ZContrast-enhanced computed tomography (CT) imaging is essential for diagnosing and monitoring thoracic diseases, including aortic pathologies. However, contrast agents pose risks such as nephrotoxicity and allergic-like reactions. The ability to generate high-fidelity synthetic contrast-enhanced CT angiography (CTA) images without contrast administration would be transformative, enhancing patient safety and accessibility while reducing healthcare costs. In this study, we propose the first bridge diffusion-based solution for synthesizing contrast-enhanced CTA images from non-contrast CT scans. Our approach builds on the Slice-Consistent Brownian Bridge Diffusion Model (SC-BBDM), leveraging its ability to model complex mappings while maintaining consistency across slices. Unlike conventional slice-wise synthesis methods, our framework preserves full 3D anatomical integrity while operating in a high-resolution 2D fashion, allowing seamless volumetric interpretation under a low memory budget. To ensure robust spatial alignment, we implement a comprehensive preprocessing pipeline that includes resampling, registration using the Symmetric Normalization method, and a sophisticated dilated segmentation mask to extract the aorta and surrounding structures. We create two datasets from the Coltea-Lung dataset: one containing only the aorta and another including both the aorta and heart, enabling a detailed analysis of anatomical context. We compare our approach against baseline methods on both datasets, demonstrating its effectiveness in preserving vascular structures while enhancing contrast fidelity.2025-08-23T05:02:16ZPouya ShiriXin YiNeel P. MistrySamaneh JavadiniaMohammad CheginiSeok-Bum KoAmirali BaniasadiScott J. Adamshttp://arxiv.org/abs/2509.04437v1From Lines to Shapes: Geometric-Constrained Segmentation of X-Ray Collimators via Hough Transform2025-09-04T17:53:45ZCollimation in X-ray imaging restricts exposure to the region-of-interest (ROI) and minimizes the radiation dose applied to the patient. The detection of collimator shadows is an essential image-based preprocessing step in digital radiography posing a challenge when edges get obscured by scattered X-ray radiation. Regardless, the prior knowledge that collimation forms polygonal-shaped shadows is evident. For this reason, we introduce a deep learning-based segmentation that is inherently constrained to its geometry. We achieve this by incorporating a differentiable Hough transform-based network to detect the collimation borders and enhance its capability to extract the information about the ROI center. During inference, we combine the information of both tasks to enable the generation of refined, line-constrained segmentation masks. We demonstrate robust reconstruction of collimated regions achieving median Hausdorff distances of 4.3-5.0mm on diverse test sets of real Xray images. While this application involves at most four shadow borders, our method is not fundamentally limited by a specific number of edges.2025-09-04T17:53:45ZBenjamin El-ZeinDominik EckertAndreas FieselmannChristopher SybenLudwig RitschlSteffen KapplerSebastian Stoberhttp://arxiv.org/abs/2505.03498v2Res-MoCoDiff: Residual-guided diffusion models for motion artifact correction in brain MRI2025-09-04T17:50:32ZObjective. Motion artifacts in brain MRI, mainly from rigid head motion, degrade image quality and hinder downstream applications. Conventional methods to mitigate these artifacts, including repeated acquisitions or motion tracking, impose workflow burdens. This study introduces Res-MoCoDiff, an efficient denoising diffusion probabilistic model specifically designed for MRI motion artifact correction.Approach.Res-MoCoDiff exploits a novel residual error shifting mechanism during the forward diffusion process to incorporate information from motion-corrupted images. This mechanism allows the model to simulate the evolution of noise with a probability distribution closely matching that of the corrupted data, enabling a reverse diffusion process that requires only four steps. The model employs a U-net backbone, with attention layers replaced by Swin Transformer blocks, to enhance robustness across resolutions. Furthermore, the training process integrates a combined l1+l2 loss function, which promotes image sharpness and reduces pixel-level errors. Res-MoCoDiff was evaluated on both an in-silico dataset generated using a realistic motion simulation framework and an in-vivo MR-ART dataset. Comparative analyses were conducted against established methods, including CycleGAN, Pix2pix, and a diffusion model with a vision transformer backbone, using quantitative metrics such as PSNR, SSIM, and NMSE.Main results. The proposed method demonstrated superior performance in removing motion artifacts across minor, moderate, and heavy distortion levels. Res-MoCoDiff consistently achieved the highest SSIM and the lowest NMSE values, with a PSNR of up to 41.91+-2.94 dB for minor distortions. Notably, the average sampling time was reduced to 0.37 seconds per batch of two image slices, compared with 101.74 seconds for conventional approaches.2025-05-06T13:02:40ZMojtaba SafariShansong WangQiang LiZach EidexRichard L. J. QiuChih-Wei ChangHui MaoXiaofeng Yang10.1088/1361-6560/ae1110http://arxiv.org/abs/2509.04024v1Electromechanical human heart modeling for predicting endocardial heart motion2025-09-04T08:55:02ZThis work presents a biventricular electromechanical human heart model that is comprehensive and clinically relevant, integrating a realistic 3D heart geometry with both systemic and pulmonary hemodynamics. The model uses a two-way fluid-structure-interaction (FSI) formulation with actual 3D blood meshes to accurately investigate the effect of blood flow on the myocardium. It couples a reaction-diffusion framework and a voltage-dependent active stress term to replicate the link between electrical excitation and mechanical contraction. Additionally, the model incorporates innovative epicardial boundary conditions to mimic the stiffness and viscosity of neighboring tissues. The model's ability to replicate physiological heart motion was validated against Cine magnetic resonance imaging (MRI) data, which demonstrated a high degree of consistency in regional displacement patterns. The analysis of the right ventricle showed that the basal and mid free walls experience the largest motion, making these regions ideal for implanting motion-driven energy harvesting devices. This validated model is a robust tool for enhancing our understanding of cardiac physiology and optimizing therapeutic interventions before clinical implementation.2025-09-04T08:55:02ZMilad HasaniAlireza RezaniaSam Riahihttp://arxiv.org/abs/2509.03958v1High-Flux Entangled Photon Generation via Clinical Megavoltage Radiotherapy Beams for Quantum Imaging and Theranostics2025-09-04T07:34:42ZTraditional sources of quantum-entangled photons, such as spontaneous parametric down-conversion, suffer from low flux, limiting clinical applications. We investigated whether clinical megavoltage (MV) radiotherapy beams can serve as dual-purpose sources, delivering therapeutic dose while simultaneously generating high-flux entangled photon pairs for quantum ghost imaging, quantum theranostics (QTX), and related applications. Using GEANT4 Monte Carlo simulations, we modeled water-equivalent phantoms containing 2 cm spherical tumors loaded with gold nanoparticles (AuNPs, 10 mg/mL). Clinical spectra at 6, 10, and 15 MV were simulated. Key metrics included 511 keV photon-pair yield, positronium lifetimes (time-resolved), Doppler and energy broadening (energy-resolved), signal-to-noise ratios (SNR), and entanglement retention at depths from 5 to 15 cm. Pair yields scaled with beam energy and AuNP concentration, reaching about 10^8 pairs per Gy per cm^3 in AuNP-loaded tumors. Positronium lifetime shifts (about 100 ps) reflected tumor oxygenation and reactive oxygen species, offering potential functional biomarkers. Doppler (1-3 keV) and AuNP-induced line broadening (0.5-1 keV) produced distinct spectroscopic signatures of electron density, tissue composition, and nanoparticle uptake. Time-resolved QTX revealed oxygenation and ROS levels, energy-resolved QTX probed tissue density and atomic composition, and combined modes enabled comprehensive theranostic imaging. Depth-dependent simulations achieved voxel SNRs exceeding 100. These findings demonstrate that clinical MV beams can serve as practical, high-flux entangled photon sources. Integrated time- and energy-resolved QTX supports functional and spectroscopic tumor imaging, enables nanoparticle optimization, and expands quantum imaging platforms from optical (eV) to therapeutic (hundreds of keV) regimes.2025-09-04T07:34:42Z19 pages, 4 figures, 3 tables, 43 referencesGustavo OliveraBashkim ZiberiStephen AveryHeth Devin SkinnerErno SajoHugo RibeiroM. Saiful Huqhttp://arxiv.org/abs/2509.03866v1Demonstrating a family of X-ray dark-field retrieval approaches on a common set of samples2025-09-04T03:58:33ZSensitive to scattering from unresolved sample structures, the dark-field channel in full-field X-ray imaging provides complementary information to that offered by conventional attenuation and phase-contrast methods. A range of experimental dark-field techniques and retrieval algorithms have been recently developed to extract this signal by directly resolving dark-field-associated local image blurring with a high-resolution camera. While the underlying physical mechanism that generates dark-field contrast is generally defined similarly across the methods, no comparison of these dark-field techniques using identical samples has been conducted. In this paper, dark-field imaging data from two samples were acquired using three emerging dark-field setups at a synchrotron: propagation-based, single-grid, and speckle-based X-ray imaging. Dark-field images were then reconstructed using a variety of retrieval algorithms--some requiring only a single sample exposure, others multiple; some performing local, pixel-wise analysis, and others operating globally on entire images. We find that the dominant contribution to dark-field contrast--arising from diffuse scattering from unresolved microstructures or multiple refractions through larger, potentially resolved structures--is consistently recovered across all approaches, demonstrating mutual agreement. However, some differences emerge for structures that are spatially varying. We attribute these differences to the idea that each technique has a different internal ruler, a sensitivity scale for dark-field retrieval influenced by both the experimental design and algorithmic assumptions of the technique. This study is intended to guide dark-field imaging users in selecting the most appropriate technique for their imaging goals and to motivate future research into dark-field sensitivity and sources of dark-field contrast across different methods.2025-09-04T03:58:33ZSamantha J. AllooYing Ying HowJannis N. AhlersDavid M. PaganinMichelle K. CroughanKaye S. Morganhttp://arxiv.org/abs/2509.00304v2Artificial Intelligence-Guided PET Image Reconstruction and Multi-Tracer Imaging: Novel Methods, Challenges, And Opportunities2025-09-03T22:56:11ZLAFOV PET/CT has the potential to unlock new applications such as ultra-low dose PET/CT imaging, multiplexed imaging, for biomarker development and for faster AI-driven reconstruction, but further work is required before these can be deployed in clinical routine. LAFOV PET/CT has unrivalled sensitivity but has a spatial resolution of an equivalent scanner with a shorter axial field of view. AI approaches are increasingly explored as potential avenues to enhance image resolution.2025-08-30T01:46:09ZPET Clinics. 2025 Aug 25Movindu DassanayakeAlejandro LopezAndrew ReaderGary J. R. CookClemens MingelsArman RahmimRobert SeifertIan AlbertsFereshteh Yousefirizi10.1016/j.cpet.2025.07.005http://arxiv.org/abs/2509.03751v1Advancing Positron Emission Tomography Image Quantification: Artificial Intelligence-Driven Methods, Clinical Challenges, and Emerging Opportunities in Long-Axial Field-of-View Positron Emission Tomography/Computed Tomography Imaging2025-09-03T22:35:42ZMTV is increasingly recognized as an accurate estimate of disease burden, which has prognostic value, but its implementation has been hindered by the time-consuming need for manual segmentation of images. Automated quantitation using AI-driven approaches is promising. AI-driven automated quantification significantly reduces labor-intensive manual segmentation, improving consistency, reproducibility, and feasibility for routine clinical practice. AI-enhanced radiomics provides comprehensive characterization of tumor biology, capturing intratumoral and intertumoral heterogeneity beyond what conventional volumetric metrics alone offer, supporting improved patient stratification and therapy planning. AI-driven segmentation of normal organs improves radioligand therapy planning by enabling accurate dose predictions and comprehensive organ-based radiomics analysis, further refining personalized patient management.2025-09-03T22:35:42ZPET Clinics. 2025 Aug 29Fereshteh YousefiriziMovindu DassanayakeAlejandro LopezAndrew ReaderGary J. R. CookClemens MingelsArman RahmimRobert SeifertIan Alberts10.1016/j.cpet.2025.07.010http://arxiv.org/abs/2504.19149v2A Kinematic and Kinetic Dataset of Lower Limb Joints During Obstacle Crossing in Healthy Young Adults2025-09-03T19:04:45ZObstacle crossing is an essential component of human locomotion, particularly for individuals with lower limb amputations who face elevated risks of imbalance and falls. While prior studies have explored this task, they often lack a comprehensive examination of kinematic and kinetic changes throughout the entire gait cycle across varying obstacle heights. This study creates a novel dataset collected from ten healthy adults performing obstacle crossing at four different heights (7.5 cm, 15 cm, 22.5 cm, and 30 cm). Kinematic and kinetic data (angles and torques of hip, knee, and ankle) were recorded and analyzed. Results indicate that increased obstacle height leads to a longer swing phase and significant increases in both hip and knee joint angles (1.5* and 1.0*, respectively) and torques. In contrast, ankle joint angles and moments exhibited minimal variation across obstacle heights, indicating a relatively consistent movement strategy at the ankle. Furthermore, significant asymmetries were observed between the dominant and non-dominant foot: the dominant foot demonstrated larger hip and knee joint angles and more consistent ankle behavior, reflecting greater coordination. These findings offer valuable biomechanical insights for improving fall prevention strategies and informing the design of assistive devices such as prostheses and exoskeletons.2025-04-27T08:06:33ZJournal of Biomechanics, 2025, Article 112979Jingwen HuangShucong YinZhaokai ChenHanyang XuChenglong Fu10.1016/j.jbiomech.2025.112979http://arxiv.org/abs/2403.17575v4MR sequence design to account for non-ideal gradient performance2025-09-03T16:39:29ZMRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy currents produced by gradient fields; usually these are compensated by pre-emphasizing demanded waveforms. This process typically happens invisibly to the pulse sequence designer, allowing them to assume achieved gradient waveforms will be as desired. Whilst convenient, this requires system specifications exposed to the end-user to be substantially down-rated, since pre-emphasis adds an extra overhead to the waveforms. This strategy is undesirable for lower performance or resource-limited hardware. Instead, we propose an optimization-based method to design pre-compensated gradient waveforms that: (i) explicitly respect hardware constraints and (ii) improve imaging performance by correcting k-space samples directly. Gradient waveforms are numerically optimized by including a model for system imperfections. This is investigated in simulation using an exponential eddy current model, then experimentally using an empirical gradient system transfer function on a 7T MRI system. Our proposed method discovers solutions that produce negligible reconstruction errors while satisfying gradient system limits, even when classic pre-emphasis produces infeasible results. Substantial reduction in ghosting artefacts from EPI imaging was observed, including an average reduction of 77% in ghost amplitude in phantoms. This work demonstrates numerical optimization of gradient waveforms, yielding substantially improved image quality when given a model for system imperfections. While the method as implemented has limited flexibility, it could enable more efficient hardware usage, and may prove particularly important for maximizing performance of lower-cost systems.2024-03-26T10:30:59Z19 pages, 6 figures (including supporting information)Daniel J WestFelix GlangJonathan EndresDavid LeitãoMoritz ZaissJoseph V HajnalShaihan J Malikhttp://arxiv.org/abs/2509.03420v1Image-Guided Surgery: Technology, Quality, Innovation, and Opportunities for Medical Physics2025-09-03T15:48:33ZThe science and clinical practice of medical physics has been integral to the advancement of radiology and radiation therapy for over a century. In parallel, advances in surgery - including intraoperative imaging, registration, and other technologies within the expertise of medical physicists - have advanced primarily in connection to other disciplines, such as biomedical engineering and computer science, and via somewhat distinct translational paths. This review article briefly traces the parallel and convergent evolution of such scientific, engineering, and clinical domains with an eye to a potentially broader, more impactful role of medical physics in research and clinical practice of surgery. A review of image-guided surgery technologies is offered, including intraoperative imaging, tracking / navigation, image registration, visualization, and surgical robotics across a spectrum of surgical applications. Trends and drivers for research and innovation are traced, including federal funding and academic-industry partnership, and some of the major challenges to achieving major clinical impact are described. Opportunities for medical physicists to expand expertise and contribute to the advancement of surgery in the decade ahead are outlined, including research and innovation, data science approaches, improving efficiency through operations research and optimization, improving patient safety, and bringing rigorous quality assurance to technologies and processes in the circle of care for surgery. Challenges abound but appear tractable, including domain knowledge, professional qualifications, and the need for investment and clinical partnership.2025-09-03T15:48:33Z20 pages, 6 figuresJeffrey H. Siewerdsenhttp://arxiv.org/abs/2509.03313v1Advancements in Monte Carlo simulations with gMicroMC: reactive species build-up promotes radical-radical reactions at Flash dose rates2025-09-03T13:43:16ZUltra-high dose rate irradiations to water indicate an enhancement of radical-radical reactions, which could potentially correlate with the Flash effect. The purpose of this work was to extend gMicroMC to support multiple pulse simulations and Flash dose rates, and to investigate, in a pure water model, the mechanisms underlying the enhancement of radical-radical reactions under Flash conditions. gMicroMC, a GPU-based Monte Carlo track-structure algorithm, was extended to simulate multiple pulses. Pure water was exposed to multiple 70 MeV protons pulses delivering up to 20 Gy. The pulse dose rate was set to 2*10^5 and 10^6 Gy/s, while the average dose rate ranged from 0.01 to 100000 Gy/s. The G-values of H2O2 were used to monitor the influence of dose rate on radical-radical reactions. The multiple pulse extension of gMicroMC was validated against Kinetiscope. Multiple pulse simulations indicated an average dose rate threshold. Below it, complete radical depletion occurred within the pulses, leading to constant G-values. Above it, reactive species accumulated throughout the irradiation, resulting in an increase of radical-radical reactions and thus the G-values of H2O2. The average dose rate thresholds were in the order of 10 and 100 Gy/s for pulse dose rates of 2*10^5 and 10^6 Gy/s, respectively. At ultra-high dose rates, the brief intervals between pulses led to a reactive species build-up, which enhanced radical-radical reactions. This build-up is more likely to promote radical-radical reactions than the inter-track mechanism. The advancements in gMicroMC provide a sophisticated tool to study chemical dose rate dependencies.2025-09-03T13:43:16Z29 pages, 9 figuresMiguel Molina-HernandezPatricia GonçalvesYujie ChiJoao Secohttp://arxiv.org/abs/2509.03255v1Anti-scatter grid prototype manufactured via laser powder bed fusion of pure tungsten2025-09-03T12:15:52ZThis paper describes the production and tests performed with the tungsten collimator prototype produced using laser powder bed fusion technology in a converging geometry. This prototype has been tested for being the anti-scatter grid for X-ray imaging to reduce background from the scattered photons. The purpose is reducing patient radiation exposure in medical applications. Obtained results are positive, grid provides definitive enhancement in marker detection which proves to be especially useful with artificially created obstacles to imitate harsher working environments.2025-09-03T12:15:52ZI. DiachkovS. ChernyshikhinS. DadabaevS. KholodenkoA. KulikV. ObraztsovE. ShmaninD. Strekalina