https://arxiv.org/api/VyfIsT4crkoGK/AUpJTihFCR7vc2026-06-26T04:10:54Z900897515http://arxiv.org/abs/2509.08407v1An Iterative LLM Framework for SIBT utilizing RAG-based Adaptive Weight Optimization2025-09-10T08:54:16ZSeed implant brachytherapy (SIBT) is an effective cancer treatment modality; however, clinical planning often relies on manual adjustment of objective function weights, leading to inefficiencies and suboptimal results. This study proposes an adaptive weight optimization framework for SIBT planning, driven by large language models (LLMs). A locally deployed DeepSeek-R1 LLM is integrated with an automatic planning algorithm in an iterative loop. Starting with fixed weights, the LLM evaluates plan quality and recommends new weights in the next iteration. This process continues until convergence criteria are met, after which the LLM conducts a comprehensive evaluation to identify the optimal plan. A clinical knowledge base, constructed and queried via retrieval-augmented generation (RAG), enhances the model's domain-specific reasoning. The proposed method was validated on 23 patient cases, showing that the LLM-assisted approach produces plans that are comparable to or exceeding clinically approved and fixed-weight plans, in terms of dose homogeneity for the clinical target volume (CTV) and sparing of organs at risk (OARs). The study demonstrates the potential use of LLMs in SIBT planning automation.2025-09-10T08:54:16ZZhuo XiaoImage Processing Center, Beihang University, Beijing, ChinaQinglong YaoImage Processing Center, Beihang University, Beijing, ChinaJingjing WangImage Processing Center, Beihang University, Beijing, ChinaFugen ZhouImage Processing Center, Beihang University, Beijing, ChinaBo LiuImage Processing Center, Beihang University, Beijing, ChinaHaitao SunDepartment of Radiation Oncology, Peking University Third Hospital, Beijing, ChinaZhe JiDepartment of Radiation Oncology, Peking University Third Hospital, Beijing, ChinaYuliang JiangDepartment of Radiation Oncology, Peking University Third Hospital, Beijing, ChinaJunjie WangDepartment of Radiation Oncology, Peking University Third Hospital, Beijing, ChinaQiuwen WuDepartment of Radiation Oncology, Duke University Medical Center, Durham, USAhttp://arxiv.org/abs/2509.08149v1The-Bodega: A Matlab Toolbox for Biologically Dynamic Microbubble Simulations on Realistic Hemodynamic Microvascular Graphs2025-09-09T21:14:04ZThe-Bodega is a Matlab-based toolbox for simulating ground-truth datasets for Ultrasound Localization Microscopy (ULM)-a super resolution imaging technique that resolves microvessels by systematically tracking microbubbles flowing through the microvasculature. The-Bodega enables open-source simulation of stochastic microbubble dynamics through anatomically complex vascular graphs and features a quasi-automated pipeline for generating ground-truth ultrasound data from simple vascular inputs. It incorporates sequential Monte Carlo simulations augmented with Poiseuille flow distributions and dynamic pulsatile flow. A key novelty of our framework is its flexibility to accommodate arbitrary vascular architectures and benchmark common ULM algorithms, such as Fourier Ring Correlation and Singular Value Decomposition (SVD) spatiotemporal filtering, on realistic hemodynamic digital phantoms. The-Bodega supports consistent microbubble-to-ultrasound simulations across domains ranging from mouse brains to human hearts and automatically leverages available CPU/GPU parallelization to improve computational efficiency. We demonstrate its versatility in applications including image quality assessment, motion artifact analysis, and the simulation of novel ULM modalities, such as capillary imaging, myocardial reconstruction under beating heart motion, and simulating neurovascular evoked responses.2025-09-09T21:14:04Z36 Pages, 12 FiguresStephen Alexander LeeAlexis LeconteAlice WuJonathan PoreeMaxence Laplante-BerthierSimon DesrocherPierre-Olivier BouchardJoshua KinugasaSamuel MihelicAndreas LinningerJean Provosthttp://arxiv.org/abs/2509.07959v1Comparison of the propulsion of helical microrobots based on hard- and soft-magnetic elements under rotating external magnetic fieldsv2025-09-09T17:45:44ZThis study compares the propulsion of helical microrobots based on hard- and soft-magnetic elements under rotating magnetic fields. Results show that hard-magnetic microrobots achieved step-out frequencies and maximum propulsion speeds 4.5 times higher than soft-magnetic microrobots. Below saturation magnetization, soft-magnetic micro-robots demonstrated similar performance irrespective of magnetic susceptibility, high-lighting that torque generation in these materials is purely geometry-dependent. Employing a tapered ribbon design increased propulsion speed by a factor of 3.5 compared to regular helical designs. These results provide a quantitative basis for selecting materials and designs, enabling designers to weigh the propulsion benefits of hard magnets against the biocompatibility of soft-magnetic microrobots.2025-09-09T17:45:44ZJoost WijnmalenLeon AbelmannIulian Apachiteihttp://arxiv.org/abs/2507.21625v2Real-Time Gradient Waveform Design for Arbitrary $k$-Space Trajectories2025-09-09T08:49:11Z\textbf{Objective: }To develop a real-time method for designing gradient waveforms for arbitrary $k$-space trajectories that are time-optimal and hardware-compliant. \textbf{Methods: }The gradient waveform is solved recursively under both the slew-rate and the trajectory constraints. The gradient constraint is enforced by thresholding the $\ell_2$-norm of the next gradient vector. The constraints form a quadratic equation. To ensure the existence of the solution, a novel Discrete-Time Forward and Backward Sweep (DTFBS) strategy is proposed. To ensure the existence of the trajectory derivatives, the trajectory function is reparameterized as a piecewise cubic polynomial function with $C^2$ continuity. To ensure trajectory fidelity, the output gradient waveform is reparameterized by the finite difference of the trajectory samples. Simulation experiments across seven commonly adopted non-Cartesian trajectories were conducted to validate generality, time-optimality, real-time capability, slew-rate accuracy, and improvements over prior work. Imaging feasibility of the designed time-optimal gradient waveform was validated in phantom and in vivo experiments. \textbf{Results: }The proposed method achieves a $>89\%$ reduction in computation time and simultaneously reduces slew-rate overshoot by $>98\%$ compared to the prior method across all involved trajectories. The computation time of the proposed method is shorter than the gradient duration for all tested cases, validating the real-time capability of the proposed method. \textbf{Conclusions: }The proposed method enables real-time and hardware-compliant gradient waveform design, achieving significant reductions in computation time and slew-rate overshoot compared to the previous method. \textbf{Significance: }This is the first method achieving real-time gradient waveform design for arbitrary $k$-space trajectories.2025-07-29T09:35:55ZRui LuoHongzhang HuangQinfang MiaoJian XuPeng HuHaikun Qihttp://arxiv.org/abs/2509.08019v1Molecular-Size Control of Properties of Therapeutic Nano-Paper Allows for Selective Drug Storage in Small Doses2025-09-09T08:13:23ZA novel concept of nano-scaled interwoven templates for drug delivery with alternating hydro- and lipophilicity properties is introduced. They are built from cellulose and peptide hydrogel in tandem, and characterized by a nano-stacked interwoven design, thus enabling for tuning the lipophilicity in the mesh nano-domains in which drug candidates of complementary lipophilicities can be embedded. This allows for low-dose-controlled consumption and therapeutic applications. Time-resolved and in-situ grazing incidence X-ray scattering studies confirm the design of the therapeutic nano-paper and create conditions suitable for the drug storage of complementary properties. The molecular design has the potential of a locally controlled, site-specific drug release on a beyond-nanomolar scale. Generalized, the design may contribute to facile developments of personalized medicine.2025-09-09T08:13:23ZElisabeth ErbesNaireeta BiswasCalvin J. GavilettMatthias SchwartzkopfKrishnayan BasuroyQing ChenAndrei ChumakovSusann FrenzkeMarc GenschKorneliya GoordeyevaPatrycja KielbSonja KirchnerVolker KörstgensPeter Müller-BuschbaumHenrike M. Müller-WerkmeisterJan RubeckSreevidya Thekku VeeduJose de Jesus Velazquez-GarciaVivian WaclawekDaniel SöderbergStephan V. RothSimone Techerthttp://arxiv.org/abs/2509.07128v1Contrast-Free Ultrasound Microvascular Imaging via Radiality and Similarity Weighting2025-09-08T18:29:15ZMicrovascular imaging has advanced significantly with ultrafast data acquisition and improved clutter filtering, enhancing the sensitivity of power Doppler imaging to small vessels. However, the image quality remains limited by spatial resolution and elevated background noise, both of which impede visualization and accurate quantification. To address these limitations, this study proposes a high-resolution cross-correlation Power Doppler (HR-XPD) method that integrates spatial radiality weighting with Doppler signal coherence analysis, thereby enhancing spatial resolution while suppressing artifacts and background noise. Quantitative evaluations in simulation and in vivo experiments on healthy human liver, transplanted human kidney, and pig kidney demonstrated that HR-XPD significantly improves microvascular resolvability and contrast compared to conventional PD. In vivo results showed up to a 2 to 3-fold enhancement in spatial resolution and an increase in contrast by up to 20 dB. High-resolution vascular details were clearly depicted within a short acquisition time of only 0.3 s-1.2 s without the use of contrast agents. These findings indicate that HR-XPD provides an effective, contrast-free, and high-resolution microvascular imaging approach with broad applicability in both preclinical and clinical research.2025-09-08T18:29:15Z22 pages,11 figuresJingyi YinJingke ZhangLijie HuangU-Wai LokRyan M DeRuiterKaipeng JiYanzhe ZhaoKate M. KnollKendra E. PetersenTao WuXiang-yang ZhuJames D KrierKathryn A. RobinsonLilach O LermanAndrew J. BentallShigao ChenChengwu Huanghttp://arxiv.org/abs/2507.11593v3Characterizing the Delivered Spill Structure of Medical Proton and Carbon-Ion Beams at MedAustron using a High Frequency Silicon Carbide Readout2025-09-08T10:21:48ZMedical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of the spill structure and instantaneous particle rate is crucial. Conventional ionization chambers, while omnipresent in clinical settings, suffer from limitations in charge resolution and integration time, making single-particle detection at high dose rates unfeasible. To address these limitations, we present a beam detection setup based on a silicon carbide (SiC) sensor and a monolithic microwave integrated circuit (MMIC), capable of detecting single particles with a full width at half maximum (FWHM) pulse duration of 500 ps. At the MedAustron ion therapy center, we characterized the spill structure of proton and carbon-ion beams delivered to the irradiation room beyond the timescale of the maximum ion revolution frequency in the synchrotron. The resulting data offer valuable insights into the beam intensity at small time scales and demonstrate the capabilities of SiC-based systems for high-flux beam monitoring.2025-07-15T16:21:23ZRevised manuscript submitted to NIM AMatthias KnopfAndreas GsponerMatthias KauselSimon WaidSebastian OnderStefan GundackerDaniel RadmanovacGiulio MagrinThomas BergauerAlbert Hirtl10.1016/j.nima.2025.170984http://arxiv.org/abs/2509.06473v1From Offline to Inline Without Pain: A Practical Framework for Translating Offline MR Reconstructions to Inline Deployment Using the Gadgetron Platform2025-09-08T09:37:58ZPurpose: To develop and validate a practical framework to overcome common issues in inline deployment of established offline MR reconstruction, including (1) delay from lengthy reconstructions, (2) limited support for multi-scan input reconstructions, (3) the need to adapt scripts for different raw formats, and (4) limited guidance and experience in retaining scanner reconstructions and applying scanner-based post-processing to custom outputs. Methods: The framework builds upon the Gadgetron platform and includes: (1) an input converter to transform ISMRMRD format raw into a Siemens format raw structure, facilitating reuse of existing code; (2) an asynchronous trigger-and-retrieve mechanism enabling long reconstructions without delaying scanner processes; (3) resource-aware scheduling for parallel execution; (4) integrated file management to support multi-scan inputs; and (5) preservation of scanner-based reconstructions and post-processing. The framework was validated on 2 Siemens scanners for SENSE, AlignedSENSE, and NUFFT reconstructions, and in a large-cohort study. Results: Minimum code modification for inline deployment has been shown, and all reconstructions were successfully executed inline without disrupting scanner workflows. Images were retrieved via automated or retro-reconstruction, with scanner-based post-processing applied to custom outputs. Multi-scan input reconstructions were executed using GPU-aware scheduling, confirming feasibility for routine and large-scale applications. In 480 consecutive examinations, inline reconstructions were retrieved in 99% of cases without disruptions. Conclusion: The framework lowers the technical barrier to inline deployment of offline reconstructions, enabling robust, scalable, and post-processing-compatible integration. It is openly available with documentation and demonstration cases to support reproducibility and community adoption.2025-09-08T09:37:58Z17 pages, 5 figuresZihan NingYannick BrackenierSarah McElroySara Neves SilvaLucilio Cordero-GrandeSam RotLiane S. CanasRebecca E ThornleyDavid LeitãoDavide PoccecaiAndrew CantellRene KerosiAnthony N PriceJon ClearyDonald J TournierJana HutterPhilippa BridgenPierluigi Di CioMichela CleriInka GranlundLucy BillimoriaYasmin BlunckShaihan MalikMarc ModatClaire J StevesJoseph V Hajnalhttp://arxiv.org/abs/2508.11838v2Deformation Driven Suction Cups: A Mechanics-Based Approach to Wearable Electronics2025-09-08T04:00:52ZWearable electronics are emerging as essential tools for health monitoring, haptic feedback, and human-computer interactions. While stable contact at the device-body interface is critical for these applications, it remains challenging due to the skin's softness, roughness, and mechanical variability. Existing methods, such as grounding structures or adhesive tapes, often suffer from contact loss, limited repeatability, and restrictions on the types of electronics they can support. Suction-based adhesives offer a promising alternative by generating negative pressure without requiring tight bands or chemical adhesives. However, most existing cup designs rely on rigid-surface assumptions and overlook mechanical interactions between suction cups and skin. Inspired by traditional cupping therapies, we present a suction-based adhesive system that attaches through elastic deformation and recovery. Using analytical modeling, numerical simulations, and experiments, we present a mechanics-based framework showing how suction performance depends on cup geometry, substrate compliance, and interfacial adhesion. We show that cup geometry should be tailored to substrate stiffness. Wide, flat suction cups perform well on rigid surfaces but fail on soft ones like skin due to substrate intrusion into the chamber. Narrow and tall domes better preserve recoverable volume and generate stronger suction. To improve sealing on rough, dry skin, we introduce a soft, tacky interfacial layer informed by a contact mechanics model. Using our design principles for skin suction adhesives, we demonstrate secure attachment of rigid and flexible components including motion sensors, haptic actuators, and electrophysiological electrodes across diverse anatomical regions. These findings provide a fundamental basis for designing the next generation of skin-friendly adhesives for wearable electronics.2025-08-15T23:15:50ZSeola LeeAndrew AkersonRoham PardakhtimEhsan HajiesmailiKevin RhodesZidong LiAndrew StanleyAmirhossein AminiDaniele PiazzaChiara DaraioTianshu Liuhttp://arxiv.org/abs/2509.05873v1Assessment of 7T task fMRI value over 3T task fMRI2025-09-07T00:04:33ZUltra-high field 7T fMRI offers notable advantages over 3T fMRI, including higher signal-to-noise and contrast-to-noise ratios, enabling finer spatial and temporal resolution. This study explores the differences in activation maps from Human Connectome Project datasets between 7T and 3T field strengths, focusing on visual identified using the Glasser atlas. Functional tasks for each scanner were designed to include visual stimuli, with data processed uniformly to ensure comparability. Results showed significantly higher beta coefficients for common regions of activation, such as V3A and V3B, in 7T compared to 3T datasets. This suggests that 7T fMRI data more accurately reflect the idealized time course of task-related conditions, likely due to improved sensitivity to blood oxygenation level-dependent (BOLD) signals. However, variations in experimental design and acquisition parameters between scanners complicate the direct comparison of beta coefficients.2025-09-07T00:04:33ZThis was a project for UW Madison MP710 Advances in Medical Magnetic Resonance-Graduate courseDalton H Bermudezhttp://arxiv.org/abs/2509.05851v1Organ Dose Conversion Factors for Murine Galactic Cosmic Ray Irradiation2025-09-06T22:11:57ZGalactic cosmic rays (GCR) are a principal source of ionizing radiation exposure for astronauts during deep space missions. Given the ambition to expand manned space exploration to distant destinations like Mars, it is essential to accurately predict the radiation doses astronauts are likely to encounter and the consequent biological impacts. Accurate dose predictions are important for operational radiation safety, ensuring risk assessments and protective measures are properly calibrated to challenges of deep space travel. The GCRsim facility at the NASA Space Radiation Laboratory enables small animal radiobiology studies of GCR exposure, offering a controlled setting to mimic the complex radiation conditions in deep space. This manuscript introduces Dose Conversion Factors (DCFs) enabling rigorous absorbed dose calculations for mice irradiated at the GCRsim. A formalism was introduced for calculating organ-level and voxel-level radiation dose to a representative mouse phantom, based on DCFs quantifying absorbed dose per unit fluence of different GCRsim species for various irradiation orientations. The PHITS Monte Carlo code was employed to compute the DCFs in units of Gy m^2 ion^-1. A library of murine DCFs was derived using the PHITS Monte Carlo code for six irradiation orientations: right-left, anterior-posterior, superior-inferior, and their opposed variations. Absorbed doses to the murine total body were calculated and compared with ion chamber measurements, which agreed within 10%. A library of dose conversion factors for mouse irradiation at GCRsim was developed and validated against measurements. These DCFs account for organ-specific variations in radiation dose from different GCR species, enabling improved assessments of potential radiogenic effects and enhancing astronaut safety for future deep space missions.2025-09-06T22:11:57Z17 pages, 6 figures, 9 tablesS. HosseiniM. SivertzE. M. AlvesL. M. CarterM. D. Storyhttp://arxiv.org/abs/2505.08400v2A Fourier finite volume approach for the optical inverse problem of quantitative photoacoustic tomography2025-09-06T08:08:55ZA new approach for solving the optical inverse problem of quantitative photoacoustic tomography is introduced, which interpolates between the well-known diffusion approximation and a radiative transfer equation based model. The proposed formulation combines a spatial finite volume scheme with a truncated Fourier expansion in the direction variable for the radiative transfer equation. The finite volume scheme provides a natural and simple approach for representing piecewise constant image data modelled using transport equations. The truncated Fourier expansion in the direction variable facilitates the interpolation between the diffusion approximation at low order, and the full radiative transfer model as the truncation limit $N\rightarrow\infty$. It is therefore possible to tune the precision of the model to the demands of the imaging application, taking $N=1$ for cases when the diffusion approximation would suffice and increasing the number of terms otherwise. We will then utilise the non-linear optimisation functionality of Matlab to address the corresponding large-scale nonlinear inverse problem using gradient based quasi-Newton minimisation via the limited memory Broyden-Fletcher-Goldfarb-Shanno algorithm. Numerical experiments for two test-cases of increasing complexity and resolution will be presented, and the effect of logarithmically rescaling the problem data on the accuracy of the reconstructed solutions will be investigated. We will focus on cases where the diffusion approximation is not sufficient to demonstrate that our approach can provide significant accuracy gains with only a modest increase in the number of Fourier terms included.2025-05-13T09:55:39Z22 pages, 7 figuresDavid J. Chappellhttp://arxiv.org/abs/2502.16333v2Optimizing normal tissue sparing via spatiotemporal optimization under equivalent tumor-radical efficacy2025-09-05T17:19:11ZObjective: Spatiotemporal optimization in radiation therapy involves determining the optimal number of dose delivery fractions (temporal) and the optimal dose per fraction (spatial). Traditional approaches focus on maximizing the biologically effective dose (BED) to the target while constraining BED to organs-at-risk (OAR), which may lead to insufficient BED for complete tumor cell kill. This work proposes a formulation that ensures adequate BED delivery to the target while minimizing BED to the OAR. Approach: A spatiotemporal optimization model is developed that incorporates an inequality constraint to guarantee sufficient BED for tumor cell kill while minimizing BED to the OAR. The model accounts for tumor proliferation dynamics, including lag time (delay before proliferation begins) and doubling time (time for tumor volume to double), to optimize dose fractionation. Results: The performance of our formulation is evaluated for varying lag and doubling times. The results show that mean BED to the target consistently meets the minimum requirement for tumor cell kill. Additionally, the mean BED to OAR varies based on tumor proliferation dynamics. In the prostate case with lag time of 7 days and doubling time of 2 days, it is observed that mean BED delivered to femoral head is lowest at around 20 fractions, making this an optimal choice. While in the head-and-neck case, mean BED to OAR decreases as the number of fractions increases, suggesting that a higher number of fractions is optimal. Significance: A spatiotemporal optimization model is presented that minimizes BED to the OAR while ensuring sufficient BED for tumor cell kill. By incorporating tumor lag and doubling time, the approach identifies optimal number of fractions. This model can be extended to support hyperfractionation or accelerated fractionation strategies, offering a versatile tool for clinical treatment planning.2025-02-22T19:46:22ZNimita ShindeWangyao LiRonald C ChenHao Gaohttp://arxiv.org/abs/2502.16332v3Minibeam-pLATTICE: A novel proton LATTICE modality using minibeams2025-09-05T17:16:56ZPurpose: LATTICE, a form of spatially fractionated radiation therapy that delivers high-dose peaks and low-dose valleys within the target, has been clinically utilized for treating bulky tumors. However, its application to small-to-medium-sized target remains challenging due to beam size limitations. To address this challenge, this work proposes a novel proton LATTICE (pLATTICE) modality using minibeams, namely minibeam-pLATTICE, that extends LATTICE approach for small-to-medium targets. Methods: Three minibeam-pLATTICE methods are introduced. (1) M0: a fixed minibeam orientation for all beam angles; (2) M1: alternated minibeam orientations, for consecutive beam angles; (3) M2: multiple minibeam orientations for each beam angle. For each minibeam-pLATTICE method, an optimization problem is formulated to optimize dose uniformity in target peaks and valleys, as well as dose-volume-histogram-based objectives. This problem is solved using iterative convex relaxation and alternating direction method of multipliers. Results: Three minibeam-pLATTICE methods are validated to demonstrate the feasibility of minibeam-pLATTICE for head-and-neck cases. The advantages of this modality over conventional beam (CONV) pLATTICE are evaluated by comparing peak-to-valley dose ratio (PVDR) and dose delivered to organs at risk (OAR). All three minibeam-pLATTICE modalities achieved improved plan quality compared to CONV, with M2 yielding the best results. For example, in terms of PVDR, M2=5.89, compared to CONV=4.13, M0=4.87 and M1=4.7. Conclusion: A novel minibeam-pLATTICE modality is proposed that generates lattice dose patterns for small-to-medium targets, which are not achievable with conventional pLATTICE due to beam size limitations.2025-02-22T19:37:49ZNimita ShindeWeijie ZhangYuting LinHao Gaohttp://arxiv.org/abs/2504.07844v2A quantum computing approach to beam angle optimization2025-09-05T17:13:28ZBackground: Beam angle optimization (BAO) is a critical component of radiation therapy (RT) treatment planning, where small changes in beam configuration can significantly impact treatment quality, especially for proton RT. Mathematically, BAO is a mixed integer programming (MIP) problem, which is NP-hard due to its exponential growing search space. Traditional optimization techniques often struggle with computational efficiency, necessitating the development of novel approaches. Purpose: This study introduces QC-BAO, a hybrid quantum-classical approach that leverages quantum computing to solve the MIP formulation of BAO. Methods: The proposed approach, QC-BAO, models BAO as an MIP problem, incorporating binary variables for beam angle selection and continuous variables for optimizing spot intensities for proton therapy. The proposed approach employs a hybrid quantum-classical framework, utilizing quantum computing to solve the binary decision component while integrating classical optimization techniques, including iterative convex relaxation and alternating direction method of multipliers. Results: Computational experiments were conducted on clinical test cases to evaluate QC-BAO's performance against clinically verified angles and a heuristic approach, GS-BAO. QC-BAO demonstrated improved treatment plan quality over both clinical and GS-BAO. The method consistently increased the conformity index (CI) for target coverage while reducing mean and maximum doses to organs-at-risk (OAR). Additionally, QC-BAO produced the lowest objective function value, confirming its superior optimization capability. Conclusions: The findings highlight the potential of quantum computing to enhance the solution to BAO problem by demonstrated improvement in plan quality using the proposed method, QC-BAO. This study paves the way for future clinical implementation of quantum-accelerated optimization in RT.2025-04-10T15:24:37ZNimita ShindeYa-Nan ZhuHaozheng ShenHao Gao