https://arxiv.org/api/H8CPgDbGpG+jHVWyYIQBmecHh7g2026-06-26T03:07:41Z900896015http://arxiv.org/abs/2509.10434v1Viewing heat through ice: an infrared camera monitors hydrogel freezing and thawing during cryoapplication2025-09-12T17:42:27ZCryosurgery employs a safe and relatively simple technique of exposure and is an advantageous and highly rated method. For its effective application, it is necessary to control both the volume of the expanding freezing zone and volumetric thermal field dynamics. The aim of this study was to perform a thermal imaging study of freezing and thawing in a model system (gel phantom) to predict the dynamics of the freezing zone during cryodestruction of biological tissues in vivo. Here, the thermal imager is an effective tool for demonstrating the surface temperature distribution. We have studied how the observed infrared image relates to the distribution and change of the thermal field in depth. For this purpose, we created test measuring equipment for simultaneous analysis of the dynamics of thermal fields on the surface, video recording of freezing and thawing on the surface as well as in the depth of the gel phantom, measuring the temperature at any given point in the depth and modeling in the zone of low-temperature exposure of vessels with different blood flow parameters. It was revealed that with a modeled vessel in the low-temperature exposure zone, the surface thermal fields deformed and they gained the shape of butterfly wings. Our experimental study in a gel phantom is supported by numerical calculations, demonstrating how the freezing zone and thermal isotherms on the surface and in depth evolve under real conditions, thereby providing a basis for assessing the cryoeffect time and intensity in practice. Key words: cryoapplication; freezing; thawing; temperature field dynamics; infrared thermography; gel phantom; testing measuring equipment; vessel simulation.2025-09-12T17:42:27ZThis article has been accepted for publication in Cryobiology (2025)Gennadiy O. KovalovInstitute for Problems of Cryobiology and Cryomedicine of the National Academy of Sciences of UkraineMykola O. ChyzhInstitute for Problems of Cryobiology and Cryomedicine of the National Academy of Sciences of UkraineVyacheslav Yu. GlobaInstitute for Problems of Cryobiology and Cryomedicine of the National Academy of Sciences of UkraineOleksandr F. TodrinInstitute for Problems of Cryobiology and Cryomedicine of the National Academy of Sciences of UkraineGalyna V. ShustakovaVerkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of UkraineEduard Yu. GordiyenkoVerkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of UkraineYuliya V. FomenkoVerkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of UkraineOleh V. IvakhnenkoVerkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of UkrainePolina O. KofmanVerkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of UkraineSergey N. ShevchenkoVerkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of Ukraine10.1016/j.cryobiol.2025.105259http://arxiv.org/abs/2509.10295v1Enhancing understanding and clinical applications of cerebral autoregulation: A novel integrated numerical framework2025-09-12T14:36:58ZCerebral autoregulation (CA) is a fundamental mechanism that modulates cerebrovascular resistance, primarily by regulating the diameter of small cerebral vessels to maintain stable cerebral blood flow (CBF) in response to fluctuations in systemic arterial pressure. However, the clinical understanding of CA remains limited due to the intricate structure of the cerebral vasculature and the challenges in accurately quantifying the hemodynamic and physiological parameters that govern this autoregulatory process. Method: In this study, we introduced a novel numerical algorithm that employs three partial differential equations and one ordinary differential equation to capture both the spatial and temporal distributions of key CA-driving factors, including the arterial pressure (P) and the partial pressures of oxygen (PO_2) and carbon dioxide (PCO_2) within the cerebral vasculature, together with a Windkessel model in turn to regulate the CBF based on the calculated P, PO_2, and PCO_2. This algorithm was sequentially integrated with our previously developed personalized 0D-1D multi-dimensional model to account for the patient-specific effects. Results: The integrated framework was rigorously validated using two independent datasets, demonstrating its high reliability and accuracy in capturing the regulatory effects of CA on CBF across a range of physiological conditions. Conclusion: This work significantly advances our understanding of CA and provides a promising foundation for developing hemodynamic-based therapeutic strategies aimed at improving clinical outcomes in patients with cerebrovascular disorders.2025-09-12T14:36:58Z17 pages, 5 figuresQi ZhangMeng-di YangXuan-hao XuXiu-li XuShuai TianLi-ling Haohttp://arxiv.org/abs/2502.18973v3Impact of deep learning model uncertainty on manual corrections to auto-segmentation in prostate cancer radiotherapy2025-09-12T11:53:24ZBackground: Deep learning (DL)-based organ segmentation is increasingly used in radiotherapy, yet voxel-wise DL uncertainty maps are rarely presented to clinicians. Purpose: This study assessed how DL-generated uncertainty maps impact radiation oncologists during manual correction of prostate radiotherapy DL segmentations. Methods: Two nnUNet models were trained by 10-fold cross-validation on 434 MRI-only prostate cancer cases to segment the prostate and rectum. Each model was evaluated on 35 independent cases. Voxel-wise uncertainty was calculated using the SoftMax standard deviation (n=10) and visualized as a color-coded map. Four oncologists performed segmentation in two steps: Step 1: Rated segmentation quality and confidence using Likert scales and edited DL segmentations without uncertainty maps. Step 2 ($\geq 4$ weeks later): Repeated step 1, but with uncertainty maps available. Segmentation time was recorded for both steps, and oncologists provided qualitative free-text feedback. Histogram analysis compared voxel edits across uncertainty levels. Results: DL segmentations showed high agreement with oncologist edits. Quality ratings varied: rectum segmentation ratings slightly decreased overall in step 2, while prostate ratings differed among oncologists. Confidence ratings also varied. Three oncologists reduced segmentation time with uncertainty maps, saving 1-2 minutes per case. Histogram analysis showed 50% fewer edits for step 2 in low-uncertainty areas. Conclusions: Presenting DL segmentation uncertainty information to radiation oncologists influences their decision-making, quality perception, and confidence in the DL segmentations. Low-uncertainty regions were edited less frequently, indicating increased trust in DL predictions. Uncertainty maps improve efficiency by reducing segmentation time and can be a valuable clinical tool, enhancing radiotherapy planning efficiency.2025-02-26T09:34:55ZViktor RogowskiAngelica SvalkvistMatteo MasperoTomas JanssenFederica Carmen MaruccioJenny GorgisyanJonas SchermanIda HäggströmVictor WåhlstrandAdalsteinn GunnlaugssonMartin P NilssonMathieu MoreauNándor VassNiclas PetterssonChristian Jamtheim Gustafssonhttp://arxiv.org/abs/2503.05367v2Semi-Supervised Learning for Dose Prediction in Targeted Radionuclide: A Synthetic Data Study2025-09-12T06:47:33ZTargeted Radionuclide Therapy (TRT) is a modern strategy in radiation oncology that aims to administer a potent radiation dose specifically to cancer cells using cancer-targeting radiopharmaceuticals. Accurate radiation dose estimation tailored to individual patients is crucial. Deep learning, particularly with pre-therapy imaging, holds promise for personalizing TRT doses. However, current methods require large time series of SPECT imaging, which is hardly achievable in routine clinical practice, and thus raises issues of data availability. Our objective is to develop a semi-supervised learning (SSL) solution to personalize dosimetry using pre-therapy images. The aim is to develop an approach that achieves accurate results when PET/CT images are available, but are associated with only a few post-therapy dosimetry data provided by SPECT images. In this work, we introduce an SSL method using a pseudo-label generation approach for regression tasks inspired by the FixMatch framework. The feasibility of the proposed solution was preliminarily evaluated through an in-silico study using synthetic data and Monte Carlo simulation. Experimental results for organ dose prediction yielded promising outcomes, showing that the use of pseudo-labeled data provides better accuracy compared to using only labeled data.2025-03-07T12:21:09Z12 pages, 13 figures, 5 tablesJing ZhangAlexandre BousseChi-Hieu PhamKuangyu ShiJulien Berthttp://arxiv.org/abs/2509.09966v1Ultra-low field 13C MRI of hyperpolarized pyruvate2025-09-12T05:00:30ZMedicine is evolving beyond therapy largely predicated on anatomical information and towards incorporating patient-specific molecular biomarkers of disease for more accurate diagnosis and effective treatment. The complementary combination of hyperpolarization by spin-lock induced crossing signal amplification by reversible exchange (SLIC SABRE) and low field magnetic resonance imaging (MRI) can enable accessible metabolic imaging to advance personalized medicine. Hyperpolarized 13C-enriched pyruvate has demonstrated utility for MRI of metabolism in cancer, heart disease and neurodegenerative disorders but has been restricted from widespread clinical adoption by a lack of access to affordable technology. Parahydrogen-based polarization techniques, paired with low-cost high-performance MRI at millitesla fields, offer a means of broadening the reach of metabolic imaging. Here we show results demonstrating in situ hyperpolarization of pyruvate at 6.5 mT by SLIC SABRE, followed by immediate readout without field cycling or sample shuttling. We achieve 13C signal enhancements several million times above thermal equilibrium at 6.5 mT, corresponding to polarization levels of approximately 3%. Leveraging this enhancement, we perform 13C MRI and acquire NMR spectra with resolution sufficient to distinguish chemical shifts between pyruvate isotopomers. These results show a viable pathway towards accessible metabolic imaging with hyperpolarized 13C MRI at ultra-low field.2025-09-12T05:00:30ZThomas BoeleStephen J. McBrideMegan PikeErica CurranPatrick TomHonHester BraaksmaSheng ShenNeha KoonjooDavid E. KorenchanEduard ChekmenevThomas TheisDavid E. J. WaddingtonMatthew S. Rosen10.1038/s42004-026-01971-2http://arxiv.org/abs/2509.09880v1Automated Tuning for Diffusion Inverse Problem Solvers without Generative Prior Retraining2025-09-11T22:22:32ZDiffusion/score-based models have recently emerged as powerful generative priors for solving inverse problems, including accelerated MRI reconstruction. While their flexibility allows decoupling the measurement model from the learned prior, their performance heavily depends on carefully tuned data fidelity weights, especially under fast sampling schedules with few denoising steps. Existing approaches often rely on heuristics or fixed weights, which fail to generalize across varying measurement conditions and irregular timestep schedules. In this work, we propose Zero-shot Adaptive Diffusion Sampling (ZADS), a test-time optimization method that adaptively tunes fidelity weights across arbitrary noise schedules without requiring retraining of the diffusion prior. ZADS treats the denoising process as a fixed unrolled sampler and optimizes fidelity weights in a self-supervised manner using only undersampled measurements. Experiments on the fastMRI knee dataset demonstrate that ZADS consistently outperforms both traditional compressed sensing and recent diffusion-based methods, showcasing its ability to deliver high-fidelity reconstructions across varying noise schedules and acquisition settings.2025-09-11T22:22:32ZIEEE International Workshop on Computational Advances in Multi-Sensor Adaptive Processing (CAMSAP), 2025Yaşar Utku AlçalarJunno YunMehmet Akçakayahttp://arxiv.org/abs/2509.09842v1Field evaluation of a wearable instrumented headband designed for measuring head kinematics2025-09-11T20:48:36ZPurpose: To study the relationship between soccer heading and the risk of mild traumatic brain injury (mTBI), we previously developed an instrumented headband and data processing scheme to measure the angular head kinematics of soccer headers. Laboratory evaluation of the headband on an anthropomorphic test device showed good agreement with a reference sensor for soccer ball impacts to the front of the head. In this study, we evaluate the headband in measuring the full head kinematics of soccer headers in the field. Methods: The headband was evaluated under typical soccer heading scenarios (throw-ins, goal-kicks, and corner-kicks) on a human subject. The measured time history and peak kinematics from the headband were compared with those from an instrumented mouthpiece, which is a widely accepted method for measuring head kinematics in the field. Results: The time history agreement (CORA scores) between the headband and the mouthpiece ranged from 'fair' to 'excellent', with the highest agreement for angular velocities (0.79 \pm 0.08) and translational accelerations (0.73 \pm 0.05) and lowest for angular accelerations (0.67 \pm 0.06). A Bland-Altman analysis of the peak kinematics from the headband and mouthpiece found the mean bias to be 40.9% (of the maximum mouthpiece reading) for the angular velocity, 16.6% for the translational acceleration, and-14.1% for the angular acceleration. Conclusion: The field evaluation of the instrumented headband showed reasonable agreement with the mouthpiece for some kinematic measures and impact conditions. Future work should focus on improving the headband performance across all kinematic measures.2025-09-11T20:48:36ZAnu TripathiYang WanZhiren ZhuFurkan CamciSheila TurcsanyiJeneel Pravin KachhadiyaMauricio Araiza CanizalesAlison BrooksHaneesh KesariJoseph AndrewsTraci SneddenPeter FerrazzanoChristian FranckRika Wright Carlsenhttp://arxiv.org/abs/2504.04563v2A new theoretical Lorentzian Apodization function: A Simulations based Comparison with traditional Apodization functions2025-09-11T16:27:01ZStandard apodization methods suppress side lobes but increase FWHM, reducing lateral resolution. Grating lobes can interfere with the main lobe, introducing artifacts in ultrasound images. A simple mathematical apodization function is needed to reduce side lobes while decreasing FWHM, thereby improving lateral resolution. The advantage of the new apodization function is that it performs comparably to the Hanning function in suppressing the first grating lobe while also reducing FWHM. This leads to improved lateral resolution and fewer artifacts caused by interference between side lobes and the main beam. Simulations using the new inverse quadratic apodization and no apodization were conducted with a wave pressure model. The new method was implemented using a rectangular function convoluted with the Fourier transform of an inverse quadratic. FWHM and the first side lobe amplitudes were quantified and compared across apodization functions. The inverse quadratic apodization outperformed no apodization in FWHM, with values of 0.906 mm and 1.22 mm, respectively. For first grating lobe suppression, the inverse quadratic and Hanning apodizations yielded -31.47 dB and -31 dB, respectively. Simulated B-mode wire phantom scans showed CNR values of 1.06 (no apodization), 1.32 (Hanning), and 1.66 (inverse quadratic). Corresponding image sharpness values were 7.3398, 6.6009, and 7.0039. The proposed apodization improves FWHM over rectangular and better suppresses the first side lobe than Hanning. Lorentzian apodization at a= 8, a= 15, the method yields superior CNR compared to standard apodizations, with only a slight trade-off in sharpness.2025-04-06T17:39:45ZDalton H Bermudezhttp://arxiv.org/abs/2509.09514v1Mapping of discrete range modulated proton radiograph to water-equivalent path length using machine learning2025-09-11T14:55:55ZObjective. Proton beams enable localized dose delivery. Accurate range estimation is essential, but planning still relies on X-ray CT, which introduces uncertainty in stopping power and range. Proton CT measures water equivalent thickness directly but suffers resolution loss from multiple Coulomb scattering. We develop a data driven method that reconstructs water equivalent path length (WEPL) maps from energy resolved proton radiographs, bypassing intermediate reconstructions. Approach. We present a machine learning pipeline for WEPL from high dimensional radiographs. Data were generated with the TOPAS Monte Carlo toolkit, modeling a clinical nozzle and a patient CT. Proton energies spanned 70-230 MeV across 72 projection angles. Principal component analysis reduced input dimensionality while preserving signal. A conditional GAN with gradient penalty was trained for WEPL prediction using a composite loss (adversarial, MSE, SSIM, perceptual) to balance sharpness, accuracy, and stability. Main results. The model reached a mean relative WEPL deviation of 2.5 percent, an SSIM of 0.97, and a proton radiography gamma index passing rate of 97.1 percent (2 percent delta WEPL, 3 mm distance-to-agreement) on a simulated head phantom. Results indicate high spatial fidelity and strong structural agreement. Significance. WEPL can be mapped directly from proton radiographs with deep learning while avoiding intermediate steps. The method mitigates limits of analytic techniques and may improve treatment planning. Future work will tune the number of PCA components, include detector response, explore low dose settings, and extend multi angle data toward full proton CT reconstruction; it is compatible with clinical workflows.2025-09-11T14:55:55ZAtiq Ur RahmanChun-Chieh WangShu-Wei WuTsi-Chian ChaoI-Chun Chohttp://arxiv.org/abs/2509.09392v1An Integrated Open Source Software System for the Generation and Analysis of Subject-Specific Blood Flow Simulation Ensembles2025-09-11T12:18:10ZBackground and Objective: Hemodynamic analysis of blood flow through arteries and veins is critical for diagnosing cardiovascular diseases, such as aneurysms and stenoses, and for investigating cardiovascular parameters, such as turbulence and wall shear stress. For subject-specific analyses, the anatomy and blood flow of the subject can be captured non-invasively using structural and 4D Magnetic Resonance Imaging (MRI). Computational Fluid Dynamics (CFD), on the other hand, can be used to generate blood flow simulations by solving the Navier-Stokes equations. To generate and analyze subject-specific blood flow simulations, MRI and CFD have to be brought together.
Methods: We present an interactive, customizable, and user-oriented visual analysis tool that assists researchers in both medicine and numerical analysis. Our open-source tool is applicable to domains such as CFD and MRI, and it facilitates the analysis of simulation results and medical data, especially in hemodynamic studies. It enables the creation of simulation ensembles with a high variety of parameters. Furthermore, it allows for the visual and analytical examination of simulations and measurements through 2D embeddings of the similarity space.
Results: To demonstrate the effectiveness of our tool, we applied it to three real-world use cases, showcasing its ability to configure simulation ensembles and analyse blood flow dynamics. We evaluated our example cases together with MRI and CFD experts to further enhance features and increase the usability.
Conclusions: By combining the strengths of both CFD and MRI, our tool provides a more comprehensive understanding of hemodynamic parameters, facilitating more accurate analysis of hemodynamic biomarkers.2025-09-11T12:18:10Z21 pages, 7 figures, 2 tablesComputers 2026, 15(5), 300Simon LeistikowThomas MiroAdrian KummerländerAli NahardaniKatja GrünMarkus FranzVerena HoerrMathias J. KrauseLars Linsen10.3390/computers15050300http://arxiv.org/abs/2509.08987v1HitPix3 -- a new HV-CMOS active pixel sensor for ion beam therapy2025-09-10T20:35:47ZParticle therapy is a well-established clinical treatment of tumors and so far, more than one hundred centers are in operation around the world. High accuracy on position and dose rate in beam monitoring are major cornerstones of clinical success in particle therapy. A high voltage CMOS (HV-CMOS) monolithic active pixel sensor was developed for this beam monitoring system. The HV-CMOS technology has demonstrated many advantages over other technologies in dealing with radiation tolerance. This HV-CMOS sensor was produced with a 180 nm commercial technology on high-resistivity substrate. The HitPix sensor features several specific design details for operation in a high-intensity ion beam environment: hit-counting pixels, on-sensor projection calculation, radiation tolerant design and frame-based readout. It has a 9775 $μ$m $\times$ 10110 $μ$m sensor area with 200 $μ$m $\times$ 200 $μ$m pixel size. The new HitPix3 has a number of improvements, including a modified in-pixel amplifier, on-sensor calculation of beam profile projection in two dimensions, and in-pixel threshold tuning capacity. The functionality of these features was confirmed in laboratory tests of unirradiated HitPix3 sensors, making the HitPix3 an important step in developing a sensor for use in ion beam monitoring.2025-09-10T20:35:47Z11 pages with 19 figures, submitted to Nuclear Inst. and Methods in Physics Research, AHui ZhangBogdan TopkoIvan Perić10.1016/j.nima.2025.171049http://arxiv.org/abs/2509.08797v1Low-Cost and Detunable Wireless Resonator Glasses for Enhanced Eye MRI with Concurrent High-Quality Whole Brain MRI2025-09-10T17:28:42ZPurpose: To develop and evaluate a wearable wireless resonator glasses design that enhances eye MRI signal-to-noise ratio (SNR) without compromising whole-brain image quality at 7 T.
Methods: The device integrates two detunable LC loop resonators into a lightweight, 3D-printed frame positioned near the eyes. The resonators passively couple to a standard 2Tx/32Rx head coil without hardware modifications. Bench tests assessed tuning, isolation, and detuning performance. B1$^+$ maps were measured in a head/shoulder phantom, and SNR maps were obtained in both phantom and in vivo experiments.
Results: Bench measurements confirmed accurate tuning, strong inter-element isolation, and effective passive detuning. Phantom B1$^+$ mapping showed negligible differences between configurations with and without the resonators. Phantom and in vivo imaging demonstrated up to about a 3-fold SNR gain in the eye region, with no measurable SNR loss in the brain.
Conclusion: The wireless resonator glasses provide a low-cost, easy-to-use solution that improves ocular SNR while preserving whole-brain image quality, enabling both dedicated eye MRI and simultaneous eye-brain imaging at ultrahigh field.2025-09-10T17:28:42ZMagn Reson Med. 2026;96(1):499-507Ming LuXiaoyue YangJason MoorePingping LiAdam W. AndersonJohn C. GoreSeth A. SmithXinqiang Yan10.1002/mrm.70326http://arxiv.org/abs/2509.08872v1WarpPINN-fibers: improved cardiac strain estimation from cine-MR with physics-informed neural networks2025-09-10T14:53:31ZThe contractile motion of the heart is strongly determined by the distribution of the fibers that constitute cardiac tissue. Strain analysis informed with the orientation of fibers allows to describe several pathologies that are typically associated with impaired mechanics of the myocardium, such as cardiovascular disease. Several methods have been developed to estimate strain-derived metrics from traditional imaging techniques. However, the physical models underlying these methods do not include fiber mechanics, restricting their capacity to accurately explain cardiac function. In this work, we introduce WarpPINN-fibers, a physics-informed neural network framework to accurately obtain cardiac motion and strains enhanced by fiber information. We train our neural network to satisfy a hyper-elastic model and promote fiber contraction with the goal to predict the deformation field of the heart from cine magnetic resonance images. For this purpose, we build a loss function composed of three terms: a data-similarity loss between the reference and the warped template images, a regularizer enforcing near-incompressibility of cardiac tissue and a fiber-stretch penalization that controls strain in the direction of synthetically produced fibers. We show that our neural network improves the former WarpPINN model and effectively controls fiber stretch in a synthetic phantom experiment. Then, we demonstrate that WarpPINN-fibers outperforms alternative methodologies in landmark-tracking and strain curve prediction for a cine-MRI benchmark with a cohort of 15 healthy volunteers. We expect that our method will enable a more precise quantification of cardiac strains through accurate deformation fields that are consistent with fiber physiology, without requiring imaging techniques more sophisticated than MRI.2025-09-10T14:53:31ZFelipe Álvarez BarrientosTomás BanducIsabeau SirvenFrancisco Sahli Costabalhttp://arxiv.org/abs/2509.08602v1A parallel algorithm for generating Pareto-optimal radiosurgery treatment plans2025-09-10T14:01:49ZUsing inverse planning tools to create radiotherapy treatment plans is an iterative process, where clinical trade-offs are explored by changing the relative importance of different objectives and rerunning the optimizer until a desirable plan is found. We seek to optimize hundreds of radiosurgery treatment plans, corresponding to different weightings of objectives, fast enough to incorporate interactive Pareto navigation of clinical trade-offs into the clinical workflow. We apply the alternating direction method of multipliers (ADMM) to the linear-program formulation of the optimization problem used in Lightning. We implement both a CPU and a GPU version of ADMM in Matlab and compare them to Matlab's built-in, single-threaded dual-simplex solver. The ADMM implementation is adapted to the optimization procedure used in the clinical software, with a bespoke algorithm for maximizing overlap between low-dose points for different objective weights. The method is evaluated on a test dataset consisting of 20 cases from three different indications, with between one and nine targets and total target volumes ranging from 0.66 to 52 cm3, yielding speedups of 1.6-97 and 54-1500 times on CPU and GPU, respectively, compared to simplex. Plan quality was evaluated by rerunning the ADMM optimization 20 times, each with a different random seed, for each test case and for nine objective weightings per case. The resulting clinical metrics closely mimicked those obtained when rerunning the simplex solver, verifying the validity of the method. In conclusion, we show how ADMM can be adapted for radiosurgery plan optimization, allowing hundreds of high-quality Gamma Knife treatment plans to be created in under two minutes on a single GPU, also for very large cases.2025-09-10T14:01:49ZJoakim da SilvaDaniel Hernández EscobarTor Kjellsson LindblomHåkan NordströmJens Sjölundhttp://arxiv.org/abs/2509.12241v1CNN-BiLSTM for sustainable and non-invasive COVID-19 detection via salivary ATR-FTIR spectroscopy2025-09-10T12:44:06ZThe COVID-19 pandemic has placed unprecedented strain on healthcare systems and remains a global health concern, especially with the emergence of new variants. Although real-time polymerase chain reaction (RT-PCR) is considered the gold standard for COVID-19 detection, it is expensive, time-consuming, labor-intensive, and sensitive to issues with RNA extraction. In this context, ATR-FTIR spectroscopy analysis of biofluids offers a reagent-free, cost-effective alternative for COVID-19 detection. We propose a novel architecture that combines Convolutional Neural Networks (CNN) with Bidirectional Long Short-Term Memory (BiLSTM) networks, referred to as CNN-BiLSTM, to process spectra generated by ATR-FTIR spectroscopy and diagnose COVID-19 from spectral samples. We compare the performance of this architecture against a standalone CNN and other state-of-the-art machine learning techniques. Experimental results demonstrate that our CNN-BiLSTM model outperforms all other models, achieving an average accuracy and F1-score of 0.80 on a challenging real-world COVID-19 dataset. The addition of the BiLSTM layer to the CNN architecture significantly enhances model performance, making CNN-BiLSTM a more accurate and reliable choice for detecting COVID-19 using ATR-FTIR spectra of non-invasive saliva samples.2025-09-10T12:44:06ZAnisio P. Santos JuniorRobinson Sabino-SilvaMário Machado MartinsThulio Marquez CunhaMurillo G. Carneiro