https://arxiv.org/api/6jvzg0+eAYagR55ZDLHeump2bzo 2026-06-26T02:03:23Z 9008 945 15 http://arxiv.org/abs/2509.14429v1 Design and Validation of Metasurface Transmitarrays for Time-Reversal Microwave Hyperthermia in Deep Brain Tumors 2025-09-17T21:03:58Z This work presents a systematic design of a metasurface-based microwave hyperthermia system, leveraging the time-reversal technique to achieve precise focusing of electromagnetic energy at deep-seated brain tumors. The manuscript includes detailed numerical simulations on realistic and spherical head models, as well as the experimental realization of a quad-layer transmissive metasurface and an electrothermal head phantom. This represents the first experimental demonstration of metasurface-based time-reversal focusing for deep brain hyperthermia, achieving localized heating while minimizing temperature rise in healthy tissue. 2025-09-17T21:03:58Z Alireza Rahmani Mohammad Javad Hajiahmadi Reza Faraji-Dana http://arxiv.org/abs/2509.14354v1 Bayesian Parameter Inference and Uncertainty-Informed Sensitivity Analysis in a 0D Cardiovascular Model for Intraoperative Hypotension 2025-09-17T18:36:17Z Computational cardiovascular models are promising tools for clinical decision support, particularly in complex conditions, such as intraoperative hypotension (IOH). IOH arises from different mechanisms, making treatment selection non-trivial. Patient-specific predictions require calibration, typically performed using deterministic approaches prone to parameter non-identifiability and lacking uncertainty quantification, hindering clinical translation. Consequently, Bayesian approaches are needed that facilitate parameter inference, sensitivity analysis, and uncertainty quantification in cardiovascular models. We utilize Bayesian Markov chain Monte Carlo (MCMC) to estimate parameter distributions of a cardiovascular lumped parameter model (LPM) across different IOH scenarios. We demonstrate parameter non-uniqueness and its impact on sensitivity indices. We improve parameter reliability by incorporating clinical knowledge and measurement uncertainties. We enable continual learning of the model using sequential parameter updating as new patient data become available. We introduce an uncertainty-aware sensitivity analysis and compare it with a deterministic approach. Deterministic calibration yielded many local solutions for IOH, with notably different sensitivities. MCMC distinguished different hypotension scenarios, such as those induced by impaired contractility or hypovolemia. Propagating uncertainties from MCMC through sensitivity analysis provided tighter credible intervals, resulting in more stable parameter rankings than the deterministic approach. The Bayesian approach revealed differences in model behavior and treatment suggestions across patient conditions. Combining Bayesian inference with sequential updating and sensitivity analysis improves the reliability and identifiability of parameter estimates, enhancing the clinical utility of LPMs for therapy guidance. 2025-09-17T18:36:17Z Jan-Niklas Thiel Marko Zlicar Ulrich Steinseifer Borut Kirn Michael Neidlin http://arxiv.org/abs/2506.16817v2 Theoretical novel medical isotope production with deuterium-tritium fusion technology 2025-09-17T08:02:55Z Background: The emergence and growth of fusion technology enables investigative studies into its applications beyond typical power production facilities. This study seeks to determine the viability of medical isotope production with the neutrons produced in an example large fusion device. Using FISPACT-II (a nuclear inventory code) and a simulated fusion spectrum, the production yields of a significant number of potentially clinically relevant (both in use and novel) medical isotopes were calculated. Comparative calculations were also conducted against existing production routes. Results: Depending on the neutron flux of the fusion device, it could be an ideal technology to produce alpha-emitters such as 212Bi/212Pb, it may be able to contribute to the production of 99mTc/99Mo, and could offer an alternative route in the production a few Auger-emitting candidates. There is also a long list of beta-emitting nuclides where fusion technology may be best placed to produce over existing technologies including 67Cu, 90Y and 47Sc. Conclusions: It is theoretically viable to produce existing and novel medical isotopes with fusion technology. However, a significant number of assumptions form the basis of this study which would need to be studied further for any particular nuclide of interest. 2025-06-20T08:15:02Z 17 pages, 2 figures. Submitted to Applied Radiation and Isotopes Lee J. Evitts Philip W. Miller Chiara Da Pieve Andrew Turner Stefano Borini 10.1016/j.apradiso.2025.112163 http://arxiv.org/abs/2509.13533v1 Quantitative In Vivo Cherenkov Luminescence Imaging and Dosimetry of Yttrium-86-NM600 2025-09-16T20:59:06Z Purpose: The expansion of radiopharmaceutical therapy (RPT) development demands scalable preclinical dosimetry methods. While PET and SPECT remain the gold standards, their low throughput and high cost limit large-cohort studies. Cherenkov luminescence imaging (CLI) offers a high-throughput alternative but suffers from depth-dependent attenuation and photon scatter that compromise quantitative accuracy. This work develops and validates a quantitative CLI methodology incorporating attenuation and scatter corrections for accurate preclinical dosimetry. Methods: Depth-dependent attenuation was characterized using a tissue-mimicking phantom to derive calibration coefficients. Photon scatter was modeled using GEANT4-generated Cherenkov spread functions (CSFs), applied in a depth-weighted iterative Richardson--Lucy deconvolution/reconvolution framework. The method was evaluated in NU/NU mice (n=4) bearing MC38 tumors after injection of $^{86}$Y-NM600, an isotope suitable for both PET and CLI. Liver and tumor activities were quantified at four timepoints using PET and the proposed CLI method. Monte Carlo dosimetry was performed for both modalities. Results: CLI--PET activity quantification yielded mean errors of 15.4% (liver) and 10.3% (tumor) over the first three timepoints. Tumor absorbed doses from CLI-derived synthetic PET images (3.4 $\pm$ 0.3 Gy/MBq) were statistically indistinguishable from PET-based estimates (3.2 $\pm$ 0.2 Gy/MBq, $p=0.31$). Discrepancies increased at late timepoints due to low activity and background auto-luminescence. Conclusions: With appropriate depth-dependent attenuation calibration and Monte Carlo--derived scatter correction, CLI can provide quantitative biodistribution and dosimetry estimates comparable to PET. This approach enables high-throughput, low-cost in vivo dosimetry, expanding the feasibility of large-scale preclinical RPT studies. 2025-09-16T20:59:06Z 34 pages, 8 figures, 2 tables Campbell Haasch Malick Bio Idrissou Sydney Jupitz Aubrey Parks Reinier Hernandez Brian Pogue Bryan Bednarz http://arxiv.org/abs/2501.18167v2 Scattering approach to diffusion quantifies axonal damage in brain injury 2025-09-16T18:03:11Z Early diagnosis and noninvasive monitoring of neurological disorders require sensitivity to elusive cellular-level alterations that occur much earlier than volumetric changes observable with the millimeter-resolution of medical imaging modalities. Morphological changes in axons, such as axonal varicosities or beadings, are observed in neurological disorders, as well as in development and aging. Here, we reveal the sensitivity of time-dependent diffusion MRI (dMRI) to the structurally disordered axonal morphology at the micrometer scale. Scattering theory uncovers the two parameters that determine the diffusive dynamics of water along axons: the average reciprocal cross-section and the variance of long-range cross-sectional fluctuations. This theoretical development allows us to predict dMRI metrics sensitive to axonal alterations over tens of thousands of axons in seconds rather than months of simulations in a rat model of traumatic brain injury, and is corroborated with ex vivo dMRI. Our approach bridges the gap between micrometers and millimeters in resolution, offering quantitative and objective biomarkers applicable to a broad spectrum of neurological disorders. 2025-01-30T06:31:04Z Nat Commun 16, 9808 (2025) Ali Abdollahzadeh Ricardo Coronado-Leija Hong-Hsi Lee Alejandra Sierra Els Fieremans Dmitry S. Novikov 10.1038/s41467-025-64793-1 http://arxiv.org/abs/2510.00009v1 In vivo solid stress is associated with poor patient survival in glioma 2025-09-15T14:47:14Z Solid stress is increasingly being recognized as a key driver of tumor progression and aggressiveness, yet it has not been directly measured in patients so far. Here, we combine multifrequency magnetic resonance elastography with 3D magnetic resonance imaging (MRI)-based diffeomorphic deformable image registration network analysis to noninvasively quantify glioma-induced solid stress. In both a mouse model and patients, we identified spatially heterogeneous deformation patterns extending well beyond tumor margins. While deformation magnitude was not found to correlate with tumor size or clinical outcome, excess solid stress - defined as the product of peritumoral volumetric strain and stiffness differential between unaffected brain and peritumoral tissue - was inversely associated with patient survival. To our knowledge, these findings provide the first in vivo indication that tumor-associated mechanical stress affects clinical outcomes and can thus serve as a quantitative, imaging-derived biomarker with potential utility for prognostication and treatment guidance in patients with glioma. 2025-09-15T14:47:14Z Noah Jaitner Mehrgan Shahryari Jakob Schattenfroh Tom Meyer Hossein S. Aghamiry Jakob Ludwig Jakob Jordan Anastasia Janas Anna Morr Biru Huang Boshra Shams Thomas Picht Gueliz Acker Tobias Schaeffter Jing Guo Ingolf Sack http://arxiv.org/abs/2508.20804v2 Ising energy model for the stochastic prediction of tumor islets 2025-09-15T14:07:19Z A major challenge in diagnosing and treating cancer is the infiltrative growth of tumors into surrounding tissues. This microscopic spread of the disease is invisible on most diagnostic imaging modalities and can often only be detected histologically in biopsies. The purpose of this paper is to develop a physically based model of tumor spread that captures the histologically observed behavior in terms of seeding small tumor islets in prostate cancer. The model is based on three elementary events: a tumor cell can move, duplicate, or die. The propensity of each event is given by an Ising-like Hamiltonian that captures correlations between neighboring cells. The model parameters were fitted to clinical data obtained from surgical specimens taken from 23 prostate cancer patients. The results demonstrate that this straightforward physical model effectively describes the distribution of the size and the number of tumor islets in prostate cancer. The simulated tumor islets exhibit a regular, approximately spherical shape, correctly mimicking the shapes observed in histology. This is due to the Ising interaction term between neighboring cells acting as a surface tension that gives rise to regularly shaped islets. The model addresses the important clinical need of calculating the probability of tumor involvement in specific sub-volumes of the prostate, which is required for radiation treatment planning and other applications. 2025-08-28T14:06:38Z Lucas Amoudruz Gregory Buti Luciano Rivetti Ali Ajdari Gregory Sharp Petros Koumoutsakos Simon Spohn Anca L Grosu Thomas Bortfeld http://arxiv.org/abs/2509.11935v1 Time-series Neutron Tomography of Rhizoboxes 2025-09-15T13:50:44Z This study investigates the feasibility of tilt-series neutron tomography for analyzing rhizoboxes used in root-soil interaction studies. Traditional neutron imaging methods are limited by constrained root growth volumes and poor penetration in moist soil. Using a vertical acquisition axis, the tilt-series approach avoids constraints typical of laminography. This method allows simultaneous radiographic and tomographic data acquisition, enhancing time resolution and providing detailed insights into root networks and soil water content. Experiments involved scanning six-week-old maize plants in rhizoboxes filled with sand. Results show that tilt-series tomography can effectively reconstruct root networks despite some artifacts from the missing wedge. While the tilt-series tomographic data qualitatively reveal water distribution changes, radiographic data remain essential for quantitative analysis. This approach demonstrates the potential for dynamic root-soil interaction studies, offering a valuable tool for agricultural and environmental research by providing comprehensive insights into the rhizosphere. 2025-09-15T13:50:44Z Presented at the 12th World Conference on Neutron Radiography June 2-7, 2024 Idaho Falls, Idaho, USA A. P. Kaestner S. Di Bert R. Jia P. Benard A. Carminati http://arxiv.org/abs/2509.08356v2 In Vivo Wideband MR Elastography for Assessing Age-Related Viscoelastic Changes of the Human Brain 2025-09-15T13:22:49Z Magnetic Resonance Elastography (MRE) noninvasively maps brain biomechanics and is highly sensitive to alterations associated with aging and neurodegenerative disease. Most implementations use a single frequency or a narrow frequency band, limiting the analysis of frequency-dependent viscoelastic parameters. We developed a dual-actuator wideband MRE (5-50 Hz) protocol and acquired wavefields at 13 frequencies in 24 healthy adults (young: 23-39 years; older: 50-63 years). Shear wave speed (SWS) maps were generated as a proxy for stiffness, and SWS dispersion was modeled using Newtonian, Kelvin-Voigt, and power-law rheological models. Whole-brain stiffness declined with age, with the strongest effect observed at low frequencies (5-16 Hz: -0.24%/year; p=0.019) compared with mid (20-35 Hz: -0.12%/year; p=0.030) and high frequencies (40-50 Hz: -0.10%/year; p=0.165). Compared to older brains, younger adults showed 14.3% higher baseline stiffness in the power-law model (p=0.001) and 8.5-9.0% higher viscosity according to the Newtonian and Kelvin-Voigt model (p<0.05). White and cortical gray matter exhibited similar age-related decreases, while deep gray matter showed an increase in the power-law exponent (+0.001/year; p=0.036), suggesting a transition toward more fluid-like properties associated with aging. Wideband MRE revealed frequency-dependent and region-specific biomechanical alterations with aging, with the strongest effects observed at low frequencies. Extending brain MRE into the low frequency regime potentially enhances sensitivity to solid-fluid interactions. Therefore, low frequency MRE may serve as an early biomechanical marker of microstructural brain changes due to aging and neurodegeneration. 2025-09-10T07:45:44Z 26 pages, 6 figures, 4 tables Jakob Schattenfroh Tom Meyer Hossein S. Aghamiry Noah Jaitner Michael Fedders Steffen Görner Helge Herthum Stefan Hetzer Melanie Estrella Guillaume Flé Paul Steinmann Jing Guo Ingolf Sack http://arxiv.org/abs/2509.11790v1 Physics-Informed Deep Unrolled Network for Portable MR Image Reconstruction 2025-09-15T11:20:13Z Magnetic resonance imaging (MRI) is the gold standard imaging modality for numerous diagnostic tasks, yet its usefulness is tempered due to its high cost and infrastructural requirements. Low-cost very-low-field portable scanners offer new opportunities, while enabling imaging outside conventional MRI suites. However, achieving diagnostic-quality images in clinically acceptable scan times remains challenging with these systems. Therefore methods for improving the image quality while reducing the scan duration are highly desirable. Here, we investigate a physics-informed 3D deep unrolled network for the reconstruction of portable MR acquisitions. Our approach includes a novel network architecture that utilizes momentum-based acceleration and leverages complex conjugate symmetry of k-space for improved reconstruction performance. Comprehensive evaluations on emulated datasets as well as 47mT portable MRI acquisitions demonstrate the improved reconstruction quality of the proposed method compared to existing methods. 2025-09-15T11:20:13Z Efe Ilıcak Chinmay Rao Chloé Najac Beatrice Lena Baris Imre Fernando Galve Joseba Alonso Andrew Webb Marius Staring http://arxiv.org/abs/2411.06704v2 Accelerating Low-field MRI: From Compressed Sensing to Deep Learning Reconstruction with CNNs and Transformers 2025-09-15T00:00:29Z Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, key barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long scan durations. Hence, methods for accelerating acquisition and boosting image quality are critically important to enable clinically actionable, high-quality imaging in these systems. Despite the role that compressed sensing (CS) and deep learning (DL)-based methods have played in improving image quality for high-field MRI, their adoption for low-field imaging is still in its infancy, and it remains unclear how robust these methods are in low-SNR regimes. Here, we propose, investigate, and compare four reconstruction approaches: (i) L1-wavelet CS; (ii) a data-driven network; (iii) an unrolled network; and (iv) a Swin Transformer Cascade. We evaluate their performance across a range of SNR values using publicly available datasets and ultra-low field (6.5 mT) MRI data. Our results show that the unrolled network and Swin Transformer cascade outperform CS and data-driven models. While transformer-based models achieve the highest performance at high SNR, unrolled convolution-based networks are more robust in ultra-low SNR settings and often outperform transformers, indicating that simpler DL architectures may be better suited to low-field MRI. This work highlights both the potential and limitations of advanced reconstruction techniques in low-field MRI and pinpoints effective DL strategies for addressing SNR challenges. 2024-11-11T04:17:08Z Efrat Shimron Shanshan Shan James Grover Neha Koonjoo Sheng Shen Thomas Boele Annabel J. Sorby-Adams John E. Kirsch Matthew S. Rosen David E. J. Waddington http://arxiv.org/abs/2506.00006v2 Active Eye Lens Dosimetry With Dosepix: Influence of Measurement Position and Lead Glass Shielding 2025-09-14T18:09:32Z In this work, the effect of the measurement position on measurements of $H_\text{p}(3)$ of a new active eye lens dosemeter prototype based on the Dosepix detector is examined. A comparison between measuring directly in front of the eye and measuring at the side of the head of an Alderson phantom showed no significant influence on the resulting $H_\text{p}(3)$ for different radiation qualities and angles. In addition, to account for the absorption effect of radiation safety glasses, pieces of lead glass were attached to the front and side of the dosemeter. Corresponding effects and consequences for radiation protection measurements have been investigated by using a human like Alderson head phantom as well as thermoluminescent dosemeters (TLDs) and the active eye lens dosemeter prototype. For specific angles, the radiation bypassed the radiation safety glasses and lead glass pieces, leading to an increase in the measured $H_\text{p}(3)$. Compared to TLDs behind radiation safety glasses, measurements with the lead glass shielded prototype resulted in lower values for $H_\text{p}(3)$. Furthermore, the results did not reproduce previous findings where larger dose values were found for Dosepix behind lead glass pieces than for the TLDs behind radiation safety glasses. A possible reason might be that the dimensions of the lead glass pieces are not representative of the radiation safety glasses in front of the eye but, ultimately, it is not yet clear what the main reason for the deviation is. Therefore, it is advisable to test the same methodology in future investigations with other eyewear models and lead glass pieces to investigate whether similar behaviors occur. 2025-05-09T09:31:13Z This work has been submitted to the IEEE for possible publication. 9 pages, 9 figures Leonie Ullmann Florian Beißer Rolf Behrens Stefan Funk Gerhard Hilgers Oliver Hupe Jürgen Roth Tom Tröltzsch Hayo Zutz Thilo Michel http://arxiv.org/abs/2509.10998v1 Optimized Designs for High-Efficiency Particle Sorting in Serpentine Microfluidic Channels 2025-09-13T22:46:12Z Efficient particle sorting in microfluidic systems is vital for advancements in biomedical diagnostics and industrial applications. This study numerically investigates particle migration and passive sorting in symmetric serpentine microchannels, leveraging inertial and centrifugal forces for label-free, high-throughput separation. Using a two-dimensional numerical model, particle dynamics were analyzed across varying flow rates, diameter ratios (1.2, 1.5, and 2), and channel configurations. The optimized serpentine geometry achieved particle separation efficiencies exceeding 95% and throughput greater than 99%.A novel scaling framework was developed to predict the minimum number of channel loops required for efficient sorting. Additionally, the robustness of the proposed scaling framework is demonstrated by its consistency with findings from previous studies, which exhibit the same trend as predicted by the scaling laws, underscoring the universality and reliability of the model. Additionally, the study revealed the significant influence of density ratio (α) on sorting efficiency, where higher α values enhanced separation through amplified hydrodynamic forces. Optimal flow rates tailored to particle sizes were identified, enabling the formation of focused particle streaks for precise sorting. However, efficiency declined beyond these thresholds due to particle entrapment in micro-vortices or boundary layers. This work provides valuable insights and design principles for developing compact, cost-effective microfluidic systems, with broad applications in biomedical fields like cell sorting and pathogen detection, as well as industrial processes requiring precise particle handlin 2025-09-13T22:46:12Z Sayan Karmakar Anish Pal Sourav Sarkar Achintya Mukhopadhyay 10.1063/5.0261598 http://arxiv.org/abs/2502.16986v4 A framework for rapid, reproducible, and high-fidelity whole-brain multi-pool CEST imaging at 3T 2025-09-13T01:59:17Z Purpose: To develop and validate a framework for rapid, accurate, and reproducible whole-brain, multi-pool chemical exchange saturation transfer (CEST) imaging at 3T, addressing challenges of long acquisition times and confounding factors. Methods: A single-shot 3D true fast imaging with steady-state precession (True FISP) sequence was optimized for whole-brain multi-pool CEST. Rapid B0, B1, and T1 mapping was performed using a dual-echo modified four-angle method. A feed-forward neural network was developed for rapid B1 correction, trained against the conventional multi-power method. The apparent exchange-dependent relaxation (AREX) metric was used to correct for T1 and magnetization transfer (MT) effects. The framework was validated in phantoms and healthy human subjects (N=8), including a test-retest reproducibility assessment. Results: The True FISP sequence yielded high-quality, whole-brain images with minimal artifacts and distortion in a clinically feasible scan time (~9 minutes). Phantom studies confirmed the effectiveness of B1 correction (coefficient of variation [CV] for MT_MTRLD decreased from 22.49% to 4.61%) and AREX-based confounder correction (CV for APT_AREX reduced from 33.6% to 6.9%). The neural network B1 correction showed excellent agreement with the conventional multi-power method in vivo (ICC > 0.97). High test-retest reproducibility was demonstrated across 96 brain regions, with the average CV for APT_AREX under 10% for over 95% of regions. Conclusion: A rapid and robust framework for whole-brain quantitative multi-pool CEST imaging was successfully developed and validated. By integrating an efficient acquisition sequence with a streamlined correction pipeline, this approach overcomes key barriers to clinical translation, enabling reliable metabolic imaging for widespread brain pathologies. 2025-02-24T09:19:46Z KEYWORDS: chemical exchange saturation transfer (CEST), amide proton transfer (APT) whole-brain, multi-pool, true fast imaging with steady-state precession (True FISP), balanced steady state free precession (bSSFP) Yupeng Wu Siyuan Fang Siyuan Wang Caixia Fu Jianqi Li http://arxiv.org/abs/2509.10718v1 Simultaneous determination of wave speed, diffusivity and nonlinearity in the Westervelt equation using complex time-periodic solutions 2025-09-12T22:18:06Z We consider an inverse problem governed by the Westervelt equation with linear diffusivity and quadratic-type nonlinearity. The objective of this problem is to recover all the coefficients of this nonlinear partial differential equation. We show that, by constructing complex-valued time-periodic solutions excited from the boundary time-harmonically at a sufficiently high frequency, knowledge of the first- and second-harmonic Cauchy data at the boundary is sufficient to simultaneously determine the wave speed, diffusivity and nonlinearity in the interior of the domain of interest. 2025-09-12T22:18:06Z Sebastian Acosta Benjamin Palacios