https://arxiv.org/api/qgedDmYkSrXHnC7ek/ueXkyqVqA2026-06-26T00:53:51Z900793015http://arxiv.org/abs/2509.17891v1Quantitative and Computational Radiobiology for Precision Radiopharmaceutical Therapies2025-09-22T15:23:03ZThis article reviews the evolving field of radiobiology, emphasizing the need for advanced multiscale, mechanistic models to optimize radiopharmaceutical therapies (RPT). While the traditional linear-quadratic (LQ) model underpins external beam radiation therapy (EBRT), RPT's unique biological and spatial complexities demand new approaches. First-principles simulations of DNA damage, repair, and multicellular responses are crucial for understanding therapeutic efficacy and toxicity. The integration of these models into personalized, digital twin frameworks promises transformative clinical applications, but progress depends on deep mechanistic insights, experimental validation, and balancing model complexity with practicality for clinical use.2025-09-22T15:23:03ZTahir YusufalyHamid AbdollahiBabak SabouryArman Rahmimhttp://arxiv.org/abs/2509.17790v1Conditional Diffusion Models for CT Image Synthesis from CBCT: A Systematic Review2025-09-22T13:50:28ZObjective: Cone-beam computed tomography (CBCT) provides a low-dose imaging alternative to conventional CT, but suffers from noise, scatter, and artifacts that degrade image quality. Synthetic CT (sCT) aims to translate CBCT to high-quality CT-like images for improved anatomical accuracy and dosimetric precision. Although deep learning approaches have shown promise, they often face limitations in generalizability and detail preservation. Conditional diffusion models (CDMs), with their iterative refinement process, offers a novel solution. This review systematically examines the use of CDMs for CBCT-to-sCT synthesis.
Methods: A systematic search was conducted in Web of Science, Scopus, and Google Scholar for studies published between 2013 and 2024. Inclusion criteria targeted works employing conditional diffusion models specifically for sCT generation. Eleven relevant studies were identified and analyzed to address three questions: (1) What conditional diffusion methods are used? (2) How do they compare to conventional deep learning in accuracy? (3) What are their clinical implications?
Results: CDMs incorporating anatomical priors and spatial-frequency features demonstrated improved structural preservation and noise robustness. Energy-guided and hybrid latent models enabled enhanced dosimetric accuracy and personalized image synthesis. Across studies, CDMs consistently outperformed traditional deep learning models in noise suppression and artefact reduction, especially in challenging cases like lung imaging and dual-energy CT.
Conclusion: Conditional diffusion models show strong potential for generalized, accurate sCT generation from CBCT. However, clinical adoption remains limited. Future work should focus on scalability, real-time inference, and integration with multi-modal imaging to enhance clinical relevance.2025-09-22T13:50:28Z36 pages, 8 figures, 3 tables, submitted to Elsevier Computerized Medical Imaging and GraphicsAlzahra AltalibChunhui LiAlessandro Perellihttp://arxiv.org/abs/2505.22687v2Hemodynamic effects of intra- and supra- deployment locations for a bioprosthetic aortic valve2025-09-22T09:06:41ZAortic valve replacement is a key surgical procedure for treating aortic valve pathologies, such as stenosis and regurgitation. The precise placement of the prosthetic valve relative to the native aortic annulus plays a critical role in the post-operative hemodynamics. This study investigates how the positioning of a biological prosthetic valve -- either intra-annular (within the native annulus) or supra-annular (slightly downstream, in the widened portion of the aortic root) -- affects cardiac fluid dynamics. Using high-fidelity numerical simulations on a patient-specific left heart model derived from CT imaging, we simulate physiological flow conditions to isolate the impact of valve placement. Unlike previous clinical studies that compare different patients and valve models, our approach evaluates the same valve in both positions within a single virtual patient, ensuring a controlled comparison. Key hemodynamic parameters are assessed, including transvalvular pressure drop, effective orifice area, wall shear stress, and hemolysis. Results reveal that supra-annular implantation offers significant advantages: lower pressure gradients, larger orifice area, and reduced shear-induced stress. Furthermore, hemolysis analysis using advanced red blood cell stress models indicates a decreased risk of blood damage in the supra-annular configuration. These findings offer valuable insights to guide valve selection and implantation strategies, ultimately supporting improved patient outcomes.2025-05-27T20:08:26ZPhysical Review Fluids, 10(9), 090501 (2025)Martino Andrea ScarpoliniGiovanni VagnoliFabio GugliettaRoberto VerziccoFrancesco Viola10.1103/khdk-91mshttp://arxiv.org/abs/2509.17448v1Monitoring Nitric Oxide in Trigeminal Neuralgia Rats with a Cerium Single-Atom Nanozyme Electrochemical Biosensor2025-09-22T07:40:03ZTrigeminal neuralgia (TN) is the most common neuropathic disorder; however, its pathogenesis remains unclear. A prevailing theory suggests that nitric oxide (NO) may induce nerve compression and irritation via vascular dilation, thereby being responsible for the condition, making real-time detection of generated NO critical. However, traditional evaluations of NO rely on indirect colorimetric or chemiluminescence techniques, which offer limited sensitivity and spatial resolution for its real-time assessment in biological environments. Herein, we reported the development of a highly sensitive NO electrochemical biosensor based cerium single-atom nanozyme (Ce1-CN) with ultrawide linear range from 1.08 nM to 143.9 μM, and ultralow detection limit of 0.36 nM, which enables efficient and real-time evaluation of NO in TN rats. In-situ attenuated total reflection surface-enhanced infrared spectroscopy combined with density functional theory calculations revealed the high-performance biosensing mechanism, whereby the Ce centers in Ce1-CN nanoenzymes adsorb NO and subsequently react with OH- to form *HNO2. Results demonstrated that NO concentration was associated with TN onset. Following carbamazepine treatment, NO production from nerves decreased, accompanied by an alleviation of pain. These findings indicate that the biosensor serves as a valuable tool for investigating the pathogenesis of TN and guiding subsequent therapeutic strategies.2025-09-22T07:40:03ZKangling TianFuhua LiRan ChenShihong ChenWenbin WeiYihang ShenMuzi XuChunxian GuoLuigi G. OcchipintiHong Bin YangFangxin Huhttp://arxiv.org/abs/2509.17433v1Exploring Machine Learning Models for Physical Dose Calculation in Carbon Ion Therapy Using Heterogeneous Imaging Data -- A Proof of Concept Study2025-09-22T07:25:07ZBackground: Accurate and fast dose calculation is essential for optimizing carbon ion therapy. Existing machine learning (ML) models have been developed for other radiotherapy modalities. They use patient data with uniform CT imaging properties. Purpose: This study investigates the application of several ML models for physical dose calculation in carbon ion therapy and compares their ability to generalize to CT data with varying resolutions. Among the models examined is a Diffusion Model, which is tested for the first time for the calculation of physical dose distributions. Methods: A dataset was generated using publicly available CT images of the head and neck region. Monoenergetic carbon ion beams were simulated at various initial energies using Geant4 simulation software. A U-Net architecture was developed for dose prediction based on distributions of material density in patients and of absorbed dose in water. It was trained as a Generative Adversarial Network (GAN) generator, a Diffusion Model noise estimator, and as a standalone network. Their performances were compared with two models from literature. Results: All models produced dose distributions deviating by less than 2% from that obtained by a full Monte Carlo simulation, even for a patient not seen during training. Dose calculation time on a GPU was in the range of 3 ms to 15 s. The resource-efficient U-Net appears to perform comparably to the more computationally intensive GAN and Diffusion Model. Conclusion: This study demonstrates that ML models can effectively balance accuracy and speed for physical dose calculation in carbon ion therapy. Using the computationally efficient U-Net can help conserve resources. The generalizability of the models to different CT image resolutions enables the use for different patients without extensive retraining.2025-09-22T07:25:07ZMiriam SchwarzeHui Khee LooeBjörn PoppePichaya TappayuthpijarnLeo ThomasHans Rabushttp://arxiv.org/abs/2509.17432v1In vivo and predictive interplay evaluation methodology for lung and esophageal cancer patients treated in free breathing with IMPT2025-09-22T07:24:05ZPurpose: Pencil beam scanning proton therapy is sensitive to respiratory motion, leading to potential dose inhomogeneities due to interplay effects. We developed and validated a predictive framework to assess interplay and motion robustness in lung and esophageal cancer patients treated under free-breathing conditions. Methods: A synthetic-breathing-based predictive model was implemented in the RayStation treatment planning system (TPS) and validated against an in vivo approach using patient-specific respiratory traces and machine log files. Both were benchmarked against the Monte Carlo engine FRED. To demonstrate the methodology, the framework was applied to two clinical cases treated on the Mevion S250i system without rescanning. Dose accumulation incorporated respiratory phase, range ($\pm$3 %), and setup ($\pm$5 mm) uncertainties. Results: Excellent agreement was observed between TPS and FRED ($<$1 % mean dose difference) and between predictive and in vivo models ($<$2 % across DVH metrics). Cumulative dose distributions for the primary CTV converged after five fractions, confirming robust delivery. Conclusions: This automated, clinically integrated framework enables pre-treatment prediction and in vivo validation of interplay and motion robustness in PBS plans. Preliminary results support its clinical utility, especially for hypofractionation and targets with large motion ($>$2 cm). A larger cohort study is ongoing and will be reported separately.2025-09-22T07:24:05ZGiorgio CartechiniEsther KneepkensGloria Vilches-FreixasIndra LubkenMarije VeldersSebastiaan NijstenMirko UnipanIlaria Rinaldihttp://arxiv.org/abs/2509.17353v1Medical AI Consensus: A Multi-Agent Framework for Radiology Report Generation and Evaluation2025-09-22T04:31:27ZAutomating radiology report generation poses a dual challenge: building clinically reliable systems and designing rigorous evaluation protocols. We introduce a multi-agent reinforcement learning framework that serves as both a benchmark and evaluation environment for multimodal clinical reasoning in the radiology ecosystem. The proposed framework integrates large language models (LLMs) and large vision models (LVMs) within a modular architecture composed of ten specialized agents responsible for image analysis, feature extraction, report generation, review, and evaluation. This design enables fine-grained assessment at both the agent level (e.g., detection and segmentation accuracy) and the consensus level (e.g., report quality and clinical relevance). We demonstrate an implementation using chatGPT-4o on public radiology datasets, where LLMs act as evaluators alongside medical radiologist feedback. By aligning evaluation protocols with the LLM development lifecycle, including pretraining, finetuning, alignment, and deployment, the proposed benchmark establishes a path toward trustworthy deviance-based radiology report generation.2025-09-22T04:31:27ZNeurIPS2025 Workshop: Evaluating the Evolving LLM Lifecycle: Benchmarks, Emergent Abilities, and ScalingAhmed T. ElboardyGhada KhoribaEssam A. Rashedhttp://arxiv.org/abs/2509.16631v1Computational Modeling of Selective Capture Mechanisms in Conduction System Pacing2025-09-20T11:09:35ZCSP is gaining clinical significance owing to its ability to restore a physiological activation sequence in the ventricles. While His bundle pacing (HBP) producing the most physiological activation is preferable, due to implant complications the selective activation of the LBB by left bundle branch area pacing (LBBAP) is considered an alternative, offering both a simpler implant and a physiological activation sequence. However, the physical mechanisms facilitating selective activation of the LBB remain poorly understood. We developed a structurally and biophysically detailed computer model of the IVS and LBB to quantitatively elucidate the role of lead position, orientation and polarity in achieving optimal s-LBBP thresholds, using a geometrically detailed model of a clinically widely used CSP lead. A deep implant within the LV sub-endocardium ensuring a direct contact between electrode and LBB is key for effective s-LBBP. For low strength s-LBBP is feasible, but capturing the LBB in its entirety could only be achieved using higher strengths that led to non-selective left bundle branch pacing (ns-LBBP). Switching the tip polarity to anodal was not beneficial, requiring higher strengths to activate the LBB. Lead orientation relative to the LBB bundles was found to influence the s-LBBP capture threshold and the number of synchronously activating bundles. The model explains the impedance trends that are clinically observed when advancing the tip through the IVS into the LBB region, as well as sudden impedance drops associated with implant complications such as septal perforation or lead dislodgement. Quantitative consistence with clinically observed trends support model credibility, and indicate that simulation may offer an effective approach for guiding the design of improved CSP leads, facilitating a selective and synchronous activation of the entire LBB.2025-09-20T11:09:35ZMohammadreza KarimanMatthias A. F. GsellEdward J. VigmondAurel NeicChristoph M. AugustinGernot Plankhttp://arxiv.org/abs/2506.09536v2Commissioning, characterization and first high dose rate irradiations at a compact X-ray tube for microbeam and minibeam radiation therapy2025-09-19T14:14:32ZMinibeam and microbeam radiation therapy promise improved treatment outcomes through reduced normal tissue toxicity at better tumor control rates. The lack of suitable compact radiation sources limits the clinical application of minibeams to superficial tumors and renders it impossible for microbeams. We developed the first prototype of a compact line-focus X-ray tube (LFXT) with technology potentially suitable for clinical translation of minibeams and microbeams. We give an overview of the commissioning process preceding first operation, present optical and radiological focal spot characterization methods, and dosimetric measurements. Additionally, we report on first preclinical in vitro cell and in vivo mouse brain irradiations conducted with the LFXT prototype. The LFXT was high voltage conditioned up to 300 kV.The focal spot characterization resulted in a strongly eccentric electron distribution with a width of 72.3 $μ$m. Dosimetry showed sharp microbeam dose profiles with steep lateral penumbras and a peak-to-valley dose ratio above 10 throughout a 70 mm thick PMMA phantom. An open-field dose rate of 4.3 Gy/s was measured at an acceleration voltage of 150 kV and a beam current of 17.4 mA at 150 mm distance from the focal spot. In vitro and in vivo experiments demonstrated the feasibility of the LFXT for minibeam and microbeam applications with field sizes of 1.5-2 cm. The mice displayed no observable side effects after whole-brain 260 $μ$m-minibeam irradiation. We successfully constructed and commissioned the first proof-of-concept LFXT prototype. Dosimetric characterizations of the achieved microbeam field showed the superiority of the LFXT compared to conventional X-ray tubes in terms of beam quality. In future developments, the remaining limitations of the prototype will be addressed for improved minibeam and first ever microbeam radiation therapy in a clinical setting.2025-06-11T09:08:59ZCP, JW, and AD share first authorshipChristian PetrichJohanna WinterAnton DimrothThomas BeiserMonika DehnJessica StolzJacopo FrignaniStephanie E. CombsFranz SchillingGhaleb NatourKurt AulenbacherThomas E. SchmidJan J. WilkensStefan Bartzschhttp://arxiv.org/abs/2509.15979v1Simultaneous real-time multispectral fluorescence and reflectance imaging for enhanced intraoperative guidance2025-09-19T13:43:52ZIntraoperative optical imaging is essential for surgical precision and patient safety, but current systems present anatomical and fluorescence information separately, causing delays and increasing cognitive load. A unified system for simultaneous visualization is critically needed to enhance guidance and efficiency. To develop and validate a multispectral imaging system that overcomes fragmented intraoperative imaging by simultaneously capturing and integrating white light reflectance and multiple fluorescence signals in real-time, enhancing surgical precision and safety. The system integrates two synchronized color cameras with optimized optical components, including custom filters and a beam splitter, tailored for clinically relevant fluorophores protoporphyrin IX (PpIX), fluorescein sodium, and indocyanine green (ICG). Advanced image processing techniques enhance visualization accuracy. Performance was evaluated using phantoms simulating clinical conditions. The system provided real time, simultaneous visualization of white light and multiple fluorescence signals without mode switching. Fluorescence emissions from PpIX, fluorescein sodium, and ICG were accurately separated using linear unmixing algorithms. Reflectance images showed high color fidelity, with Delta E values indicating imperceptible to barely perceptible differences compared to a conventional camera. Latency was minimal, ensuring immediate visual feedback suitable for intraoperative use. This multispectral imaging system addresses the limitations of fragmented intraoperative imaging by enabling continuous, real time, integrated visualization of anatomical and fluorescence information. It streamlines workflow, reduces cognitive load, and supports more precise interventions. By leveraging components similar to conventional surgical microscopes, it offers a practical, cost effective solution aligned with clinical needs.2025-09-19T13:43:52Z15 pages, 7 FiguresKyriakos PentarakisGeorge KakavelakisConstantinos PetridisGeorge Themelishttp://arxiv.org/abs/2509.15818v1Scalable CVD Graphene Field-Effect Transistor Platform for Viral Detection: Application to COVID-192025-09-19T09:45:41ZThe rapid and global spread of coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), underscored the urgent need for fast, reliable, and adaptable diagnostic tools capable of responding to current and future viral threats. Early diagnosis is key to limiting transmission, and biosensors based on nanomaterials offer promising solutions for accurate and rapid bioanalyte detection. In this work, we present a scalable matrix of graphene-based field-effect transistors (GFETs) for the direct and rapid detection of the SARS-CoV-2 spike protein. High-quality graphene is functionalized in a single step with ACE2-His, enabling detection of the spike protein with a limit of detection as low as 1 fg/mL in phosphate-buffered saline (PBS). A robust statistical analysis, based on measurements from approximately 70 devices per analyte concentration, demonstrates the reproducibility and reliability of the platform. This label-free, scalable, and reproducible COVID-19 antigen sensor can be readily adapted to detect emerging SARS-CoV-2 variants or other viral pathogens, offering a flexible approach for future diagnostic applications.2025-09-19T09:45:41ZLeonardo MartiniYlea VlamidisIleana ArmandoDomenica ConvertinoVaidotas MišeikisValerio VolianiCamilla Colettihttp://arxiv.org/abs/2510.00015v1An infection-responsive collagen-based wet-spun textile fibre for wound monitoring2025-09-18T14:34:05ZWound infections are a significant clinical and socioeconomic challenge, contributing to delayed healing and increased wound chronicity. To enable early infection detection and inform therapeutic decisions, this study investigated the design of pH-responsive collagen fibres using a scalable wet spinning process, evaluating product suitability for textile dressings and resorbable sutures. Type I collagen was chemically functionalised with 4-vinylbenzyl chloride, enabling UV-induced crosslinking and yielding mechanically robust fibres. Bromothymol blue, a halochromic dye responsive to pH changes, was incorporated via drop-casting to impart visual infection-responsive colour change. Gravimetric analysis and Fourier Transform Infrared Spectroscopy confirmed high dye loading, whereby a Loading Efficiency of 99+/-3 wt.% was achieved. The fibres exhibited controlled swelling in aqueous environments (Swelling Ratio: 323+/-79 - 492+/-73 wt.%) and remarkable wet-state Ultimate Tensile Strength (UTS: 12+/-3 - 15+/-7 MPa), while up to ca. 30 wt.% of their initial crosslinked mass was retained after 24 hours in a collagenase-rich buffer (pH 7.4, 37°C, 2 CDU) and ethanol series dehydration. Importantly, distinct and reversible colour transitions were observed between acidic (pH 5) and alkaline (pH 8) environments, with up to 88 wt.% dye retention following 72-hour incubation. The fibres were successfully processed into woven dressing prototypes and demonstrated knotting ability suitable for suture applications. Overall, these wet-spun collagen fibres integrate infection-responsive capability, biodegradability, and scalable fabrication, representing a promising platform for smart wound dressings and resorbable sutures.2025-09-18T14:34:05Z8 Figures, 2 Schemes, 2 Tables. Accepted in PolymerJonathon GormanCharles BrookerXinyu LiGiuseppe Troncihttp://arxiv.org/abs/2509.14768v1Quantitative Stain Mapping in X-ray Virtual Histology2025-09-18T09:18:20ZVirtual histology is an emerging field in biomedicine that enables three-dimensional tissue visualization using X-ray micro-computed tomography. However, the method still lacks the specificity of conventional histology, in which parts of the tissue are selectively highlighted using targeted stains. Though some first X-ray stains have been developed to address this issue, their precise location and quantity inside the tissue volume remain largely unknown. In this work, we present a novel approach to virtual histology that simultaneously captures electron number density and X-ray attenuation values through modulation-based X-ray imaging with a structured phase modulator. These complementary measurements enable decomposition of tissue volumes into basis materials, which allows the extraction of three-dimensional maps of molar contrast agent distribution alongside morphological details on the micrometer scale -- here demonstrated on murine kidneys. The concentration values are validated against the established method of K-edge subtraction imaging. We also create a direct bridge from X-ray to visible light imaging by detecting the same stain both using classical histology and our proposed X-ray approach. Our methodology opens new possibilities for biomedical research into disease progression by providing quantitative three-dimensional stain mapping across entire tissue volumes alongside high-contrast morphology, enabling deeper insights into disease mechanisms.2025-09-18T09:18:20ZDominik JohnDavid M. PaganinMarie-Christine ZdoraLisa Marie PetzoldPatrick IlgJunan ChenSara BaggioJohannes B. ThalhammerSami WirtensohnJulian MoosmannJörg U. HammelFelix BeckmannSamantha J. AllooJannis AhlersMadleen BusseJulia HerzenKaye S. Morgan10.1002/advs.202519783http://arxiv.org/abs/2509.14660v1A Noninvasive and Dispersive Framework for Estimating Nonuniform Conductivity of Brain Tumor in Patient-Specific Head Models2025-09-18T06:38:58ZWe propose a noninvasive and dispersive framework for estimating the spatially nonuniform conductivity of brain tumors using MR images. The method consists of two components: (i) voxel-wise assignment of tumor conductivity based on reference values fitted to the Cole-Cole model using empirical data from the literature and (ii) fine-tuning of a deep learning model pretrained on healthy participants. A total of 67 cases, comprising both healthy participants and tumor patients and including 9,806 paired T1- and T2-weighted MR images, were used for training and evaluation. The proposed method successfully estimated patient-specific conductivity maps, exhibiting smooth spatial variations that reflected tissue characteristics, such as edema, necrosis, and rim-associated intensity gradients observed in T1- and T2-weighted MR images. At 10 kHz, case-wise mean conductivity values varied across patients, ranging from 0.132 to 0.512 S/m in the rim (defined as the region within 2 mm of the tumor boundary), from 0.132 to 0.608 S/m in the core (the area inside the rim), and from 0.141 to 0.542 S/m in the entire tumor. Electromagnetic simulations for transcranial magnetic stimulation in individualized head models showed substantial differences in intratumoral field distributions between uniform assignments and the proposed nonuniform maps. Furthermore, this framework demonstrated voxel-wise dispersive mapping at 10 kHz, 1 MHz, and 100 MHz. This framework supports accurate whole-brain conductivity estimation by incorporating both individual anatomical structures and tumor-specific characteristics. Collectively, these results advance patient-specific EM modeling for tumor-bearing brains and lay the groundwork for subsequent microwave-band validation.2025-09-18T06:38:58ZThis work has been submitted to the IEEE for possible publicationYoshiki KubotaYosuke NagataManabu TamuraAkimasa Hiratahttp://arxiv.org/abs/2509.14429v1Design and Validation of Metasurface Transmitarrays for Time-Reversal Microwave Hyperthermia in Deep Brain Tumors2025-09-17T21:03:58ZThis work presents a systematic design of a metasurface-based microwave hyperthermia system, leveraging the time-reversal technique to achieve precise focusing of electromagnetic energy at deep-seated brain tumors. The manuscript includes detailed numerical simulations on realistic and spherical head models, as well as the experimental realization of a quad-layer transmissive metasurface and an electrothermal head phantom. This represents the first experimental demonstration of metasurface-based time-reversal focusing for deep brain hyperthermia, achieving localized heating while minimizing temperature rise in healthy tissue.2025-09-17T21:03:58ZAlireza RahmaniMohammad Javad HajiahmadiReza Faraji-Dana