https://arxiv.org/api/x7eELaSgaf7vc9M4GGd1/T02qGQ 2026-06-25T23:47:00Z 9007 915 15 http://arxiv.org/abs/2509.21217v1 Contour-informed inter-patient deformable registration of Head-and-Neck patients 2025-09-25T14:24:46Z Background and Purpose: Voxel-based analysis (VBA) helps to identify dose-sensitive regions by aligning individual dose distributions within a common coordinate system (CCS). Accurate deformable image registration (DIR) is essential for addressing anatomical variability across patients. To improve both global and region-specific alignment, we enhanced our in-house DIR algorithm (CPT-DIR) with contour-informed regularisations. We tested its performance for head-and-neck (HN) CT images. Materials and Methods: We developed and evaluated contour-informed CPT-DIR on 37 HN CTs, including 7 with ground-truth dose for warped dose validation. Bone contours were generated using TotalSegmentator, while other organs at risk (OARs) were manually delineated. Contour-based constraints, such as Dice Similarity, were integrated to enhance registration outcome. The global registration results were evaluated using MAE, SSIM and PSNR. Geometric accuracy and warped dose accuracy were assessed using Dice Similarity Coefficient (DSC) and Dose-Organ Overlap (DOO). Constrained and unconstrained CPT-DIR were compared to B-spline. Results: CPT-DIR achieved superior accuracy with a MAE of 98.9\pm6.3 HU, lower than 179.1\pm17.8 HU for B-spline. Incorporating brainstem contours as regularisation improved the DSC from 0.604\pm0.116 to 0.878\pm0.017 and DOO from 0.430\pm0.117 to 0.753\pm0.043 for brainstem. Across all metrics, the enhanced CPT-DIR outperformed the B-spline, confirming its advantages in geometric accuracy. Conclusions: The integration of contour-informed regularisation in CPT-DIR improved DIR accuracy, particularly in dosimetrically relevant regions. This enhanced spatial alignment enabled more precise dose mapping for VBA and demonstrated strong potential for advancing reliable inter-patient dosimetric studies in HN radiotherapy. 2025-09-25T14:24:46Z Xingyue Ruan Xia Li Muheng Li Barbara Bachtiary Antony Lomax Zhiling Chen Ye Zhang http://arxiv.org/abs/2509.21184v1 Dynamic transitions for fast joint acquisition and reconstruction of CEST-Rex and T1 2025-09-25T14:00:16Z Purpose: This work proposes a method for the simultaneous estimation of the exchange-dependent relaxation rate Rex and the longitudinal relaxation time T1 from a single acquisition. Methods: A novel acquisition scheme was developed that combines CEST saturation with an inversion pulse and a Look-Locker readout to capture the magnetization evolution starting from the inverse transient Z-spectrum. The corresponding signal model, derived from the Bloch-McConnell equations, describes both the transient Z-spectrum and the Look-Locker dynamics. A model-based reconstruction approach is employed to jointly estimate Rex and T1. The proposed method was validated using a numerical phantom and benchmarked against conventional CEST and Look-Locker T1 mapping in phantom and in vivo on a clinical 3T scanner. Results: The joint estimation approach demonstrated strong agreement with ground truth and conventional methods across a wide range of T1 and CEST parameters. The acquisition time was reduced by 20-30% compared to standard CEST protocols, while providing higher signal-to-noise ratio (SNR) in parameter maps. Conclusion: The proposed technique enables robust and efficient simultaneous quantification of CEST Rex and T1 in a single acquisition. It improves parameter map quality and reduces scan time, making it suitable for both phantom and in vivo imaging across a wide range of physiological conditions. 2025-09-25T14:00:16Z Magnetic Resonance in Medicine 2026;95:2153-2168 Markus Huemer Clemens Stilianu Nick Scholand Daniel Mackner Martin Uecker Moritz Zaiss and Rudolf Stollberger http://arxiv.org/abs/2509.21165v1 Roadmap towards Personalized Approaches and Safety Considerations in Non-Ionizing Radiation: From Dosimetry to Therapeutic and Diagnostic Applications 2025-09-25T13:50:23Z This roadmap provides a comprehensive and forward-looking perspective on the individualized application and safety of non-ionizing radiation (NIR) dosimetry in diagnostic and therapeutic medicine. Covering a wide range of frequencies, i.e., from low-frequency to terahertz, this document provides an overview of the current state of the art and anticipates future research needs in selected key topics of NIR-based medical applications. It also emphasizes the importance of personalized dosimetry, rigorous safety evaluation, and interdisciplinary collaboration to ensure safe and effective integration of NIR technologies in modern therapy and diagnosis. 2025-09-25T13:50:23Z 101 pages, 5 figures Ilkka Laakso Margarethus Marius Paulides Sachiko Kodera Seungyoung Ahn Christopher L. Brace Marta Cavagnaro Ji Chen Zhi-De Deng Valerio De Santis Yinliang Diao Lourdes Farrugia Mauro Feliziani Serena Fiocchi Francesco Fioranelli Takashi Hikage Sergey Makaroff Maya Mizuno Alexander Opitz Emma Pickwell-MacPherson Punit Prakash Dario B. Rodrigues Kensuke Sasaki Takuya Sakamoto Zachary Taylor Hubregt J. Visser Desmond T. B. Yeo Akimasa Hirata http://arxiv.org/abs/2509.20963v1 4D Computational Ultrasound Imaging of Carotid Artery Flow 2025-09-25T10:03:47Z Computational ultrasound imaging (cUSi) with few elements and spatial field encoding can provide high-resolution volumetric B-mode imaging. In this work, we extend its application to 4D carotid artery (CA) flow imaging using a custom large-aperture 240-element matrix probe. We implemented a frequency band-based matched filtering strategy that balances resolution and contrast. The system's inherent imaging capabilities were evaluated and validated in flow phantom and human CA experiments. In the phantom study, 3D/4D power Doppler image and speckle-tracking analyses confirmed the system's ability to resolve flow structures and hemodynamics. In the human study, the CA bifurcation flow structure and its local pulsatile flow dynamics were successfully reconstructed. These results demonstrate the feasibility of using a large-footprint, few-element cUSi system for 4D CA flow assessment. 2025-09-25T10:03:47Z The submission consists of an 11-page manuscript with 5 figures, followed by 2 pages of supplemental files Yuyang Hu Michael Brown Didem Dogan Mahé Bulot Maxime Cheppe Guillaume Ferin Geert Leus Antonius F. W. van der Steen Pieter Kruizinga Johannes G. Bosch http://arxiv.org/abs/2407.07709v4 Motion simulation of radio-labeled cells in whole-body positron emission tomography 2025-09-25T09:11:36Z Cell tracking is a subject of active research gathering great interest in medicine and biology. Positron emission tomography (PET) is well suited for tracking radio-labeled cells in vivo due to its exceptional sensitivity and whole-body capability. For validation, ground-truth data are desirable that realistically mimic the flow of cells in a clinical situation. This study develops a workflow (CeFloPS) for simulating moving radio-labeled cells in a human phantom. From the XCAT phantom, the blood vessels are reduced to nodal networks along which cells can move and distribute to organs and tissues. The movement is directed by the blood flow, which is calculated in each node using the Hagen-Pooiseuille equation and Kirchhoff's laws assuming laminar flow. Organs are voxelized and movement of cells from artery entry to vein exit is generated via a biased 3D random walk. The probabilities of cells moving or remaining in tissues are derived from rate constants of tracer kinetic-based compartment modeling. PET listmode data is generated using the Monte-Carlo simulation framework GATE based on the definition of a large-body PET scanner with cell paths as moving radioactive sources and the XCAT phantom providing attenuation data. From the flow simulation of 100,000 cells, 100 sample cells were further processed by GATE and listmode data was reconstructed into images for comparison. As demonstrated by comparisons of simulated and reconstructed cell distributions, CeFloPS is capable of simulating cell behavior in whole-body PET. It achieves this simulation in a way that is anatomically and physiologically reasonable, thereby providing valuable data for the development and validation of cell tracking algorithms. 2024-07-10T14:39:30Z 12 pages, 12 figures Nils Marquardt Tobias Hengsbach Marco Mauritz Benedikt Wirth Klaus Schäfers 10.1109/TMI.2025.3614767 http://arxiv.org/abs/2509.20732v1 Deep-learning-based Radiomics on Mitigating Post-treatment Obesity for Pediatric Craniopharyngioma Patients after Surgery and Proton Therapy 2025-09-25T04:25:53Z Purpose: We developed an artificial neural network (ANN) combining radiomics with clinical and dosimetric features to predict the extent of body mass index (BMI) increase after surgery and proton therapy, with advantage of improved accuracy and integrated key feature selection. Methods and Materials: Uniform treatment protocol composing of limited surgery and proton radiotherapy was given to 84 pediatric craniopharyngioma patients (aged 1-20 years). Post-treatment obesity was classified into 3 groups (<10%, 10-20%, and >20%) based on the normalized BMI increase during a 5-year follow-up. We developed a densely connected 4-layer ANN with radiomics calculated from pre-surgery MRI (T1w, T2w, and FLAIR), combining clinical and dosimetric features as input. Accuracy, area under operative curve (AUC), and confusion matrices were compared with random forest (RF) models in a 5-fold cross-validation. The Group lasso regularization optimized a sparse connection to input neurons to identify key features from high-dimensional input. Results: Classification accuracy of the ANN reached above 0.9 for T1w, T2w, and FLAIR MRI. Confusion matrices showed high true positive rates of above 0.9 while the false positive rates were below 0.2. Approximately 10 key features selected for T1w, T2w, and FLAIR MRI, respectively. The ANN improved classification accuracy by 10% or 5% when compared to RF models without or with radiomic features. Conclusion: The ANN model improved classification accuracy on post-treatment obesity compared to conventional statistics models. The clinical features selected by Group lasso regularization confirmed our practical observation, while the additional radiomic and dosimetric features could serve as imaging markers and mitigation methods on post-treatment obesity for pediatric craniopharyngioma patients. 2025-09-25T04:25:53Z 20 pages, 5 figures, 3 tables Wenjun Yang Chia-Ho Hua Tina Davis Jinsoo Uh Thomas E. Merchant http://arxiv.org/abs/2509.20728v1 Interpreting Convolutional Neural Network Activation Maps with Hand-crafted Radiomics Features on Progression of Pediatric Craniopharyngioma after Irradiation Therapy 2025-09-25T04:21:03Z Purpose: Convolutional neural networks (CNNs) are promising in predicting treatment outcome for pediatric craniopharyngioma while the decision mechanisms are difficult to interpret. We compared the activation maps of CNN with hand crafted radiomics features of a densely connected artificial neural network (ANN) to correlate with clinical decisions. Methods: A cohort of 100 pediatric craniopharyngioma patients were included. Binary tumor progression was classified by an ANN and CNN with input of T1w, T2w, and FLAIR MRI. Hand-crafted radiomic features were calculated from the MRI using the LifeX software and key features were selected by Group lasso regularization, comparing to the activation maps of CNN. We evaluated the radiomics models by accuracy, area under receiver operational curve (AUC), and confusion matrices. Results: The average accuracy of T1w, T2w, and FLAIR MRI was 0.85, 0.92, and 0.86 (ANOVA, F = 1.96, P = 0.18) with ANN; 0.83, 0.81, and 0.70 (ANOVA, F = 10.11, P = 0.003) with CNN. The average AUC of ANN was 0.91, 0.97, and 0.90; 0.86, 0.88, and 0.75 of CNN for the 3 MRI, respectively. The activation maps were correlated with tumor shape, min and max intensity, and texture features. Conclusions: The tumor progression for pediatric patients with craniopharyngioma achieved promising accuracy with ANN and CNN model. The activation maps extracted from different levels were interpreted with hand-crafted key features of ANN. 2025-09-25T04:21:03Z 17 pages, 4 figures, 2 tables Wenjun Yang Chuang Wang Tina Davis Jinsoo Uh Chia-Ho Hua Thomas E. Merchant http://arxiv.org/abs/2508.19370v2 Comparative analysis of corneal and lens doses in nuclear medicine and impact of lead eyeglasses: a Monte Carlo simulation approach 2025-09-25T03:37:48Z Objective: Research on eye lens dosimetry for radiation workers has increased after the 2012 ICRP118 update on eye lens dose limits. However, corneal dosimetry remains underexplored due to historical focus and measurement challenges. This study uses a high-resolution digital eye phantom in Monte Carlo simulations to estimate corneal and lens doses for nuclear medicine staff, with and without lead glasses. Method: The Monte Carlo code GATE (version 9.0) based on GEANT4 (version 10.6) was used to estimate and compare doses in a digital eye phantom, accounting for primary and scattered radiation from common radionuclides (F18, I131, Tc99m) with varying lead glass shielding (0 to 0.75 mm). Results: Across all radionuclides, the dose to the cornea was consistently higher than the dose to the lens. Notably, the ratio of corneal to lens dose increased with thicker lead glasses, indicating a greater dose reduction to the lens compared to the cornea. Conclusion: The findings show that corneal doses from all studied radionuclides exceeded lens doses. Although increasing lead glass thickness reduced both, the reduction was more significant for the lens, raising the cornea-to-lens dose ratio. This trend suggests that while thicker lead glasses enhance lens protection, their practicality may be limited due to diminishing returns and potential discomfort. Keywords: Corneal Dosimetry, Lens Dosimetry, Monte Carlo, GATE, Nuclear Medicine, Simulation 2025-08-26T19:04:03Z This article is accepted by Journal of Optics and Photonics Research (eISSN: 3029-1348), 2025 Zahra Akbari Khanaposhtani Hossein Rajabi http://arxiv.org/abs/2509.16328v2 The Role of High-Performance GPU Resources in Large Language Model Based Radiology Imaging Diagnosis 2025-09-24T19:08:24Z Large-language models (LLMs) are rapidly being applied to radiology, enabling automated image interpretation and report generation tasks. Their deployment in clinical practice requires both high diagnostic accuracy and low inference latency, which in turn demands powerful hardware. High-performance graphical processing units (GPUs) provide the necessary compute and memory throughput to run large LLMs on imaging data. We review modern GPU architectures (e.g. NVIDIA A100/H100, AMD Instinct MI250X/MI300) and key performance metrics of floating-point throughput, memory bandwidth, VRAM capacity. We show how these hardware capabilities affect radiology tasks: for example, generating reports or detecting findings on CheXpert and MIMIC-CXR images is computationally intensive and benefits from GPU parallelism and tensor-core acceleration. Empirical studies indicate that using appropriate GPU resources can reduce inference time and improve throughput. We discuss practical challenges including privacy, deployment, cost, power and optimization strategies: mixed-precision, quantization, compression, and multi-GPU scaling. Finally, we anticipate that next-generation features (8-bit tensor cores, enhanced interconnect) will further enable on-premise and federated radiology AI. Advancing GPU infrastructure is essential for safe, efficient LLM-based radiology diagnostics. 2025-09-19T18:13:12Z Jyun-Ping Kao http://arxiv.org/abs/2509.20012v1 GPU-accelerated FREDopt package for simultaneous dose and LETd proton radiotherapy plan optimization via superiorization methods 2025-09-24T11:29:42Z This study presents FREDopt, a newly developed GPU-accelerated open-source optimization software for simultaneous proton dose and dose-averaged LET (LETd) optimization in IMPT treatment planning. FREDopt was implemented entirely in Python, leveraging CuPy for GPU acceleration and incorporating fast Monte Carlo (MC) simulations from the FRED code. The treatment plan optimization workflow includes pre-optimization and optimization, the latter equipped with a novel superiorization of feasibility-seeking algorithms. Feasibility-seeking requires finding a point that satisfies prescribed constraints. Superiorization interlaces computational perturbations into iterative feasibility-seeking steps to steer them toward a superior feasible point, replacing the need for costly full-fledged constrained optimization. The method was validated on two treatment plans of patients treated in a clinical proton therapy center, with dose and LETd distributions compared before and after reoptimization. Simultaneous dose and LETd optimization using FREDopt led to a substantial reduction of LETd and (dose)x(LETd) in organs at risk (OARs) while preserving target dose conformity. Computational performance evaluation showed execution times of 14-50 minutes, depending on the algorithm and target volume size-satisfactory for clinical and research applications while enabling further development of the well-tested, documented open-source software. 2025-09-24T11:29:42Z 29 pages. Open Access at: https://iopscience.iop.org/article/10.1088/1361-6560/ade841 Phys. Med. Biol. 70 155011 (2025) Damian Borys Jan Gajewski Tobias Becher Yair Censor Renata Kopeć Marzena Rydygier Angelo Schiavi Tomasz Skóra Anna Spaleniak Niklas Wahl Agnieszka Wochnik Antoni Ruciński http://arxiv.org/abs/2509.19268v1 A Low-cost Quasi-planar Array Probe for Photoacoustic Imaging 2025-09-23T17:29:37Z Photoacoustic imaging (PAI) is a novel hybrid imaging technique that combines the benefits of both optical and acoustic imaging modalities, which provides functional and molecular optical contrasts of deep tissue. Commonly used ultrasound transducers for PAI include linear and planar arrays, which can provide two-dimensional (2D) and three-dimensional (3D) image reconstruction, respectively. However, linear arrays cannot provide reconstruction of 3D images, which makes it impossible to locate chromophores in 3D space. Although planar array can provide fast 3D imaging in real time, it usually requires thousands of analog-to-digital conversion channels for data acquisition, which is costly. To fill the gap between 2D and 3D PAI, we propose a quasi-planar array that uses double 16-elements-linear arrays arranged in parallel to achieve real-time 3D imaging. We first conducted simulation studies to prove that the quasi-planar probe can perform 3D imaging to localize simple chromophores. Then, the agarose phantom experiment demonstrated that the probe can reconstruct 3D imaging of multiple absorbers in different depths. A potential application of this device is to provide a low-cost 3D PAI solution for fast tracking of needle tip during needle biopsy, which will be further explored in our future work. 2025-09-23T17:29:37Z 4 pages, 4 figures Xiyu Chen Junxiang Cai Rui Zheng Tao Wu Fei Gao http://arxiv.org/abs/2509.18999v1 Digital Twins of Mechanically Ventilated Preterm Neonates with Respiratory Distress Syndrome 2025-09-23T13:45:34Z Background: Mechanical ventilation is life-saving for preterm infants with respiratory distress syndrome but can also contribute to lung injury and long-term morbidity. Protective ventilation strategies are recommended, yet implementation in neonatal intensive care units remains inconsistent, and infants continue to be exposed to injurious ventilator settings. Objective: To develop and validate a cohort of neonatal digital twins, based on mechanistic models of cardiopulmonary physiology calibrated to individual patient data, as a tool for simulating and optimising protective ventilation strategies. Methods: A high-fidelity computational simulator of human cardiopulmonary physiology was adapted to neonatal-specific parameters, including lung compliance, dead space, pulmonary vascular resistance, oxygen consumption, and fetal haemoglobin oxygen affinity. Digital twins were generated using data at 65 time points from 11 preterm neonates receiving volume-controlled ventilation. Model parameters were calibrated to minimise the error between simulated and observed PaO2, PaCO2, and peak inspiratory pressure (PIP). Results: Digital twins reproduced measured data with mean absolute percentage errors of 3.9% (PaO2), 3.0% (PaCO2), and 5.8% (PIP) across the cohort. Predictions for uncalibrated variables (pHa, SaO2, mean and minimum airway pressure) also showed high accuracy, with errors <5%. Strong correlations and narrow limits of agreement were observed across all patients and time points. Conclusions: This study demonstrates, for the first time, the feasibility of creating fully mechanistic digital twins of mechanically ventilated neonates with RDS. The twins accurately captured patient-specific gas exchange and respiratory mechanics, supporting their potential as a platform for conducting virtual clinical trials and for the design of individualized, lung-protective ventilation strategies. 2025-09-23T13:45:34Z 18 pages, 2 tables, 4 figures Sina Saffaran Tng Chang Kwok Don Sharkey Declan G. Bates http://arxiv.org/abs/2509.18427v1 CPT-4DMR: Continuous sPatial-Temporal Representation for 4D-MRI Reconstruction 2025-09-22T21:18:26Z Four-dimensional MRI (4D-MRI) is an promising technique for capturing respiratory-induced motion in radiation therapy planning and delivery. Conventional 4D reconstruction methods, which typically rely on phase binning or separate template scans, struggle to capture temporal variability, complicate workflows, and impose heavy computational loads. We introduce a neural representation framework that considers respiratory motion as a smooth, continuous deformation steered by a 1D surrogate signal, completely replacing the conventional discrete sorting approach. The new method fuses motion modeling with image reconstruction through two synergistic networks: the Spatial Anatomy Network (SAN) encodes a continuous 3D anatomical representation, while a Temporal Motion Network (TMN), guided by Transformer-derived respiratory signals, produces temporally consistent deformation fields. Evaluation using a free-breathing dataset of 19 volunteers demonstrates that our template- and phase-free method accurately captures both regular and irregular respiratory patterns, while preserving vessel and bronchial continuity with high anatomical fidelity. The proposed method significantly improves efficiency, reducing the total processing time from approximately five hours required by conventional discrete sorting methods to just 15 minutes of training. Furthermore, it enables inference of each 3D volume in under one second. The framework accurately reconstructs 3D images at any respiratory state, achieves superior performance compared to conventional methods, and demonstrates strong potential for application in 4D radiation therapy planning and real-time adaptive treatment. 2025-09-22T21:18:26Z Xinyang Wu Muheng Li Xia Li Orso Pusterla Sairos Safai Philippe C. Cattin Antony J. Lomax Ye Zhang http://arxiv.org/abs/2509.18378v1 Neural Network-Driven Direct CBCT-Based Dose Calculation for Head-and-Neck Proton Treatment Planning 2025-09-22T20:01:32Z Accurate dose calculation on cone beam computed tomography (CBCT) images is essential for modern proton treatment planning workflows, particularly when accounting for inter-fractional anatomical changes in adaptive treatment scenarios. Traditional CBCT-based dose calculation suffers from image quality limitations, requiring complex correction workflows. This study develops and validates a deep learning approach for direct proton dose calculation from CBCT images using extended Long Short-Term Memory (xLSTM) neural networks. A retrospective dataset of 40 head-and-neck cancer patients with paired planning CT and treatment CBCT images was used to train an xLSTM-based neural network (CBCT-NN). The architecture incorporates energy token encoding and beam's-eye-view sequence modelling to capture spatial dependencies in proton dose deposition patterns. Training utilized 82,500 paired beam configurations with Monte Carlo-generated ground truth doses. Validation was performed on 5 independent patients using gamma analysis, mean percentage dose error assessment, and dose-volume histogram comparison. The CBCT-NN achieved gamma pass rates of 95.1 $\pm$ 2.7% using 2mm/2% criteria. Mean percentage dose errors were 2.6 $\pm$ 1.4% in high-dose regions ($>$90% of max dose) and 5.9 $\pm$ 1.9% globally. Dose-volume histogram analysis showed excellent preservation of target coverage metrics (Clinical Target Volume V95% difference: -0.6 $\pm$ 1.1%) and organ-at-risk constraints (parotid mean dose difference: -0.5 $\pm$ 1.5%). Computation time is under 3 minutes without sacrificing Monte Carlo-level accuracy. This study demonstrates the proof-of-principle of direct CBCT-based proton dose calculation using xLSTM neural networks. The approach eliminates traditional correction workflows while achieving comparable accuracy and computational efficiency suitable for adaptive protocols. 2025-09-22T20:01:32Z Muheng Li Evangelia Choulilitsa Lisa Fankhauser Francesca Albertini Antony Lomax Ye Zhang http://arxiv.org/abs/2509.18307v1 Comparison of Adaptive plan doses using Velocity generated synthetic CT with KV CBCT and re-planning CT 2025-09-22T18:32:32Z Introduction: This study uses KV CBCT based Synthetic CT (sCT) generated through Velocity workstation and compare the target and normal tissue doses with Adaptive plan CT doses. Methods: Thirty head and neck cancer patients undergoing Adaptive Radiation Therapy (ART) were included in this retrospective study. Initially, patient underwent treatment with the primary plan. After subsequent indications of major changes in patients' physicality and anatomy adaptive CT scans were acquired as per institutional protocol. Both the primary planning CT and the indicative cone-beam CT (CBCT) last acquired before the commencement of the adaptive treatment were imported into Velocity workstation. Rigid and deformable image registration techniques were used for the generation of a Synthetic CT (sCT). Simultaneously replanning was done on re-planning CT (rCT) for adaptive plan execution. The primary plan dose was subsequently mapped and deformed onto the Synthetic CT in Velocity workstation, allowing for a comparative dosimetric analysis between the sCT and rCT plan doses. This comparison was conducted in both Velocity and Eclipse, focusing on dose variations across different organs at risk (OARs) and the planning target volume (PTV). Additionally, dosimetric indices were evaluated to assess and validate the accuracy and quality of the synthetic CT-based dose mapping relative to adaptive planning. Results: The dosimetric comparison between sCT and rCT stated that Mean dose for OARs and PTVs were found to be similar in the two planning and the level of confidence by using T-statistics. Collaborative research has the potential to eliminate the need of rCT as a standard requirement. Conclusion: The sCT shows comparable CT numbers and doses to the replanning CT, suggesting it's potential as a replacement pending clinical correlation and contour adjustments. 2025-09-22T18:32:32Z 8 pages; comments welcome! Sudam Masanta Gurvinder Singh Shefali Pahwa Shekhar Dwivedi Devaraju Sampathirao Ramandeep Singh