https://arxiv.org/api/MrSQSTubUItouBf458G+OwLLlxI2026-06-25T22:35:35Z900790015http://arxiv.org/abs/2509.24676v1Real-Time Motion Correction in Magnetic Resonance Spectroscopy: AI solution inspired by fundamental science2025-09-29T12:15:22ZMagnetic Resonance Spectroscopy (MRS) is a powerful non-invasive tool for metabolic tissue analysis but is often degraded by patient motion, limiting clinical utility. The RECENTRE project (REal-time motion CorrEctioN in magneTic Resonance) presents an AI-driven, real-time motion correction pipeline based on optimized GRU networks, inspired by tagging and fast-trigger algorithms from high-energy physics. Models evaluated on held-out test sets achieve good predictive performance and overall positive framewise displacement (FD) gains. These results demonstrate feasibility for prospective scanner integration; future work will complete in-vivo validation.2025-09-29T12:15:22ZBenedetta ArgientoAlberto AnnoviSilvia CapuaniMatteo CacioppoAndrea CiardielloRoberto CoccurelloStefano GiaguFederico GioveAlessandro LonardoFrancesca Lo CiceroAlessandra MaiuroCarlo Mancini TerraccianoMario MerolaMarco MontuoriEmilia NisticòPierpaolo PerticaroliBiagio RossiCristian RossiElvira RossiFrancesco SimulaCecilia Voenahttp://arxiv.org/abs/2509.24123v1Left-lateralized reduced white matter structural connectivity in young women with obesity: analysis of graph theory applied to inter-tract correlation matrices2025-09-28T23:42:42ZObjective: Differences in WM structural connectivity were sought by comparing graph measures from young women with normal weight ($D_\mathrm{norm}$) and obesity ($D_\mathrm{over}$), studying FA-based inter-tract correlation matrices.
Methods: Undirected binary adjacency matrices were created from WM inter-tract correlation matrices. Sixteen global graph measures were compared between the $D_\mathrm{norm}$ and $D_\mathrm{over}$ groups. At the nodal level, four graph measures were compared. Optimal community structures were calculated using the Louvain community detection algorithm. This was done considering all network, as well as the left and right hemispheres separately.
Results: At the global level and considering all network, the $D_\mathrm{over}$ group had significantly reduced global efficiency compared to the $D_\mathrm{norm}$ group. Considering only the right hemisphere, none of the graph measures were significantly different between the two groups. Studying only the left hemisphere, the $D_\mathrm{over}$ group obtained significantly reduced measures compared to the $D_\mathrm{norm}$ group in five global graph measures. At the nodal level, the $D_\mathrm{over}$ group obtained significantly reduced graph measures in WM tracts when studying all network and the left hemisphere separately. These tracts were mainly involved in the reward network. The optimal community structures calculated were consistent with the results reported.
Conclusion: The $D_\mathrm{over}$ group showed altered and reduced structural connectivity in WM tracts compared to the $D_\mathrm{norm}$ group. The reported tracts are involved in reward processing, inhibitory control, executive decision-making, and cognitive processing. In addition to obtaining results consistent with those reported in the literature, it was additionally observed that the results were lateralized to the left hemisphere.2025-09-28T23:42:42ZJosé Gerardo Suárez-GarcíaEduardo Moreno-BarbosaJavier M. Hernández-LópezJorge Velázquez-CastroBenito de Celis-Alonsohttp://arxiv.org/abs/2509.23785v1A quantitative analysis of intraventricular bioimpedance in an in vivo pilot study with contextual pressure measurements2025-09-28T10:09:37ZHydrocephalus is a neurological condition characterized by disturbed cerebrospinal fluid (CSF) dynamics and is typically treated with shunt systems that drain excessive CSF out of the ventricular system. Continuous monitoring of ventricular CSF volume, however, remains a major unmet need in the clinical management of this condition. While intraventricular bioimpedance (BI) has been proposed as a potential marker of CSF volume, prior investigations have been limited to simulations, in vitro phantoms, and small animal models. This work presents the development of a measurement system for intraventricular BI and its evaluation in a large animal model. The measurement system was first validated in vitro using a mechatronic test bench replicating physiological CSF dynamics and subsequently applied in an in vivo pilot study with concurrent CSF and blood pressure monitoring. Time series analysis of the recorded signals revealed physiological BI waveform components linked to the cardiac and respiratory cycles. In addition, changes in BI following CSF volume alterations induced through intrathecal bolus infusions of artificial CSF were observed and found to be correlated to changes in CSF and blood pressures. These results provide the first in vivo evidence in a large animal model that BI reflects CSF dynamics as well as cerebral hemodynamics. Complementing intracranial pressure and CSF drainage measurements in smart shunt systems with BI could enable more comprehensive patient monitoring and physiologically informed control of hydrocephalus therapy.2025-09-28T10:09:37ZFabian FlürenbrockChristian T. StoeckMarkus F. OertelMiriam WeisskopfMelanie N. ZeilingerMarianne Schmid DanersLeonie Kornhttp://arxiv.org/abs/2503.22820v3Correlative Symmetric Index: An alternative mathematical evaluation for beam profile symmetry2025-09-27T17:35:16ZBackground: Current mathematical quantification methods for beam symmetry are highly sensitive to noise, especially in beam profiles with significant variation. Purpose: This study evaluates the accuracy of standard radiotherapy beam symmetry metrics and compares them to a proposed cross-correlation-based metric called the Correlative Symmetric Index (CSI), as well as the Structural Similarity Index (SSIM). We aim to demonstrate that CSI is less susceptible to noise than traditional methods. Methods: Simulated non-symmetric beam profiles with similar left and right areas were analyzed using both standard and proposed symmetry metrics. To test the robustness of each method to noise, a noisy non-symmetric beam profile was also generated. Measured beam profiles at various depths in a water tank were used to compare the performance of each symmetry metric under realistic clinical conditions. Results: In the noisy, non-symmetric case, CSI and SSIM values were 0.387 and 0.5401, respectively. Traditional metrics such as the Point Difference Quotient (PDQ) and area-based symmetry yielded values of 0.312 and 0.400. The percentage change between the non-symmetric (no noise) and non-symmetric (with noise) cases for PDQ, area-based symmetry, SSIM, and CSI were 11.1%, 5.6%, 16.25%, and 1.43%, respectively. For clinically measured symmetric profiles, all metrics produced values above 0.9. Conclusion: The Correlative Symmetric Index (CSI) demonstrates greater robustness to noise than both pointwise and area-based symmetry methods. CSI provides a reliable measure for quantifying beam symmetry, particularly under noisy conditions.2025-03-28T18:37:40ZDalton H BermudezWesley Culbersonhttp://arxiv.org/abs/2509.23317v1Multifractal features of multimodal cardiac signals: Nonlinear dynamics of exercise recovery2025-09-27T14:04:30ZWe investigate the recovery dynamics of healthy cardiac activity after physical exertion using multimodal biosignals recorded with a polycardiograph. Multifractal features derived from the singularity spectrum capture the scale-invariant properties of cardiovascular regulation. Five supervised classification algorithms - Logistic Regression (LogReg), Suport Vector Machine with RBF kernel (SVM-RBF), k-Nearest Neighbors (kNN), Decision Tree (DT), and Random Forest (RF) - were evaluated to distinguish recovery states in a small, imbalanced dataset. Our results show that multifractal analysis, combined with multimodal sensing, yields reliable features for characterizing recovery and points toward nonlinear diagnostic methods for heart conditions.2025-09-27T14:04:30Z10 pages, 7 FiguresA. MaluckovD. StojanovicM. MileticLj. HadzievskiJ. Petrovichttp://arxiv.org/abs/2509.23136v1Mapping fat-water separated R1, R2*, and proton density fat fraction with the multi-echo MP2RAGE sequence2025-09-27T05:39:08ZPurpose: To develop a technique for joint measurement of fat and water-specific longitudinal relaxation rates (R1f and R1w), effective transverse relaxation rate (R2*), and proton density fat fraction (PDFF) combining the Multi-Echo Magnetization Prepared Two Rapid Acquisition of Gradient Echoes (ME-MP2RAGE) sequence and fat-water separation.
Theory and Methods: R1f and R1w were calculated with fat-specific and water-specific MP2RAGE signals. R2* and PDFF maps were obtained from fat-water separation applied to the second RAGE block. Sequence parameters optimization was performed via Cramér-Rao lower bounds theory, and we designed four protocols with different combinations of number of echoes and readout gradient schemes (I: 3 echoes unipolar, II: 6 echoes unipolar, III: 6 echoes bipolar, and IV: 10 echoes bipolar). We tested and validated these protocols with numerical simulations, phantom and in vivo experiments. In phantoms, we compared ME-MP2RAGE measurements with inversion recovery spin-echo (IR-SE) global R1 and 3D Fast Low Angle Shot (3D FLASH) R2* and PDFF. In vivo, we scanned the lower leg and neck of a healthy volunteer.
Results: Numerical simulations showed accurate quantification of relaxation rates with mean relative bias < 3% and PDFF with mean bias < 0.003 using protocol ME-MP2RAGE IV (10 echoes bipolar). Phantom experiments showed excellent agreement with IR-SE and 3D FLASH measurements. In vivo, measurements in the lower leg and neck were consistent with literature values.
Conclusion: We proposed an accurate method for simultaneous quantification of R1f, R1w, R2*, and PDFF from a single acquisition with the ME-MP2RAGE sequence.2025-09-27T05:39:08ZThe manuscript is 4,837 words in length and has 8 figures and 2 table. Additional tables and figures are presented in the Supplementary InformationJorge Campos PazmiñoMarc-Antoine FortinVéronique FortierEvan McNabbRenée-Claude BiderAndré van der KouweIves R. Levesquehttp://arxiv.org/abs/2509.22865v1Simulation of Transcatheter Therapies for Atrioventricular Valve Regurgitation in an Open-Source Finite Element Simulation Framework2025-09-26T19:24:03ZPurpose: Transcatheter edge-to-edge repair (TEER) and annuloplasty devices are increasingly used to treat mitral valve regurgitation, yet their mechanical effects and interactions remain poorly understood. This study aimed to establish an open-source finite element modeling (FEM) framework for simulating patient-specific mitral valve repairs and to evaluate how TEER, annuloplasty, and combined strategies influence leaflet coaptation and valve mechanics. Methods: Four G4 MitraClip geometries were modeled and deployed in FEBio to capture leaflet grasp and subsequent clip-leaflet motion under physiologic pressurization. CardioBand annuloplasty was simulated by reducing annular circumference via displacement-controlled boundary conditions, and Mitralign suture annuloplasty was modeled using discrete nodal constraints. Simulations were performed for prolapse and dilated annulus cases. Valve competence (regurgitant orifice area, ROA), coaptation/contact area (CA), and leaflet stress and strain distributions were quantified. Results: In prolapse, TEER restored coaptation but increased leaflet stresses, whereas band and suture annuloplasty produced distinct valve morphologies with lower stress distributions. In dilation, TEER alone left residual regurgitation, while annuloplasty improved closure. Combined TEER & band annuloplasty minimized ROA, maximized CA, and reduced stresses relative to TEER alone, though stresses remained higher than annuloplasty alone. Conclusion: This study establishes a reproducible, open-source FEM framework for simulating transcatheter TEER and annuloplasty repairs, with the potential to be extended beyond the mitral valve. By quantifying the mechanical trade-offs of TEER, suture annuloplasty, band annuloplasty, and their combinations, this methodology highlights the potential of virtual repair to guide patient selection and optimize surgical planning.2025-09-26T19:24:03Z30 pages, 8 figures, 1 tableSeda AslanNicolas R. MangineDevin W. LaurencePatricia M. SabinWensi WuChristian HerzJustin S. UngerSteve A. MaasMatthew J. GillespieJeffrey A. WeissMatthew A. Jolleyhttp://arxiv.org/abs/2509.24911v1Modeling Bilateral Lymphatic Head and Neck Tumour Progression for Personalized Elective Target Volume Definition2025-09-26T17:07:52ZObjective: Large irradiated volumes are a major contributor to severe side-effects in patients with head and neck cancer undergoing curatively intended radiotherapy. We propose a data-driven approach for defining the elective clinical target volume (CTV-E) on a patient-specific basis, with the potential to reduce irradiated volumes compared to standard guidelines. Approach: We introduce a bilateral Bayesian Network (BN), trained on a large cohort, to estimate the patient-specific risk of undetected nodal involvement for both ipsilateral and contralateral lymph node levels (LNLs) I, II, III, and IV, using clinical features, such as patterns of nodal involvement, T-stage, tumour location. By applying risk thresholds, we generated individualized, risk-dependent CTV-E's for representative patient scenarios and compared the resulting treatment volumes and residual risk to those recommended by standard clinical guidelines. Main results: We computed the risks for a set of representative patient scenarios including 1) N0 (T1 and T2 tumour stage), 2) N+ in ipsilateral LNL II (T1 and T2 tumour stage), 3) N+ in ipsilateral LNL II and III (T1 and T2 tumour stage), and 4) N+ of both ipsilateral and contralateral LNL II (T3 and T4 tumour stage). Depending on the chosen risk threshold, the bilateral BN allowed for reductions in irradiated volumes relative to standard clinical protocols. For every patient scenario considered, the CTV-E's defined by the applied risk thresholds were associated with a low estimated probability of undetected nodal involvement in any excluded LNL. Significance: We present a data-driven framework for personalized CTV-E definition, encouraging the discussion of more patient-specific elective nodal target volumes, with potential for de-escalation of irradiated elective volumes.2025-09-26T17:07:52ZKristoffer MoosAnne Ivalu Sander HolmYoel Perez HaasRoman LudwigJesper Grau EriksenStine Sofia Korremanhttp://arxiv.org/abs/2404.15274v4Metric-Guided Conformal Bounds for Probabilistic Image Reconstruction2025-09-26T17:05:48ZModern deep learning reconstruction algorithms generate impressively realistic scans from sparse inputs, but can often produce significant inaccuracies. This makes it difficult to provide statistically guaranteed claims about the true state of a subject from scans reconstructed by these algorithms. In this study, we propose a framework for computing provably valid prediction bounds on claims derived from probabilistic black-box image reconstruction algorithms. The key insights behind our framework are to represent reconstructed scans with a derived clinical metric of interest, and to calibrate bounds on the ground truth metric with conformal prediction (CP) using a prior calibration dataset. These bounds convey interpretable feedback about the subject's state, and can also be used to retrieve nearest-neighbor reconstructed scans for visual inspection. We demonstrate the utility of this framework on sparse-view computed tomography (CT) for fat mass quantification and radiotherapy planning tasks. Results show that our framework produces bounds with better semantical interpretation than conventional pixel-based bounding approaches. Furthermore, we can flag dangerous outlier reconstructions that look plausible but have statistically unlikely metric values.2024-04-23T17:59:12ZAccepted as Long Oral at UNSURE @ MICCAI 2025. 11 pages, 4 figures, 1 table, 2 algorithms. Code available at https://github.com/matthewyccheung/conformal-metric. Previously titled "Metric-guided Image Reconstruction Bounds via Conformal Prediction"Matt Y CheungTucker J NethertonLaurence E CourtAshok VeeraraghavanGuha Balakrishnanhttp://arxiv.org/abs/2509.22488v1Organ dose optimization for a point-of-care forearm X-ray photon-counting CT2025-09-26T15:35:05ZBackground: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has been assessed using the computed tomography dose index (CTDI). However, emerging dosimetric approaches aim to enable patient-specific evaluations by estimating organ absorbed doses, providing a more accurate representation of the biological impact. This study investigates spectral shaping for an extremity photon-counting detector (PCD) CT, through organ absorbed dose estimation and image quality evaluation. Method: Monte Carlo simulations were conducted to evaluate various combinations of source voltage and filtration. Tube voltage ranged from 80 to 140 kV, combined with three distinct filtration material and thicknesses. Simulations included three stages: a standardized phantom for CTDI assessment, an adult forearm phantom for organ dose measurement, and an image quality phantom for evaluation of an advanced image quality metric: the detectability index. Results: In a wrist PCD-CT imaging protocol, operating the source at 80 kV can reduce the radiation dose by up to 50%. This reduction is achieved while maintaining the same detectability index value as the standard 120 kV protocol. However, the optimal filtration depends on the organ targeted for dose reduction, as bone and skin benefit from opposing filtration approaches. While CTDI provides a useful initial estimate, it may lead to suboptimal optimization compared to organ-specific dose evaluation. Conclusions: Patient-specific dosimetry based on organ absorbed dose estimation offers a more accurate framework for optimizing CT protocols through spectral shaping than conventional CTDI-based approaches.2025-09-26T15:35:05ZPierre-Antoine RodeschAnaïs ViryMouad KhorsiFabio BecceJérôme DametLucía Gallego Manzanohttp://arxiv.org/abs/2509.22198v1Characterizing Timing Parameters in Commercial SERF-OPM Multichannel Systems for Biomagnetic Field Sensing2025-09-26T11:03:54ZSpin-Exchange Relaxation-Free Optically Pumped Magnetometers (SERF-OPMs) are increasingly used in multichannel biomagnetic sensing, yet their timing performance remains poorly characterized. This contribution presents the first cross-platform study of time delay, group delay, intra-channel variability, and settling time across four commercial SERF-OPM systems: Neuro-1 and QZFM Gen.2 (QuSpin Inc.), and HEDscan and FLv2 (FieldLine Inc.). Measurements were performed inside a magnetically shielded room (BMSR-2.1, PTB, Berlin) using an already introduced test bench. Results show frequency-dependent delays of 1-10 ms, intra-channel spreads up to +-1 ms, group delays between 1-15 ms, and settling times of 2-55 ms. Clear differences in manufacturer strategies were observed: QuSpin minimizes intra-channel variability through digital delay equalization, whereas FieldLine employs per-sensor calibration to optimize bandwidth and phase matching. In all systems, the time delay deviation between channels is in the sub-millisecond range in the 20-140 Hz band, which is sufficient for magnetoencephalography source localization. However, longer settling times in some platforms limit performance for rapid stimulation protocols. These findings provide the first vendor-comprehensive benchmarks for timing parameters in commercial SERF-OPM systems. They highlight the trade-offs between bandwidth, delay, and calibration strategies, and underscore the need for rigorous timing characterization to ensure waveform fidelity. The results are directly relevant to applications such as stimulation-evoked responses, brain-computer interfaces, and closed-loop neuromodulation.2025-09-26T11:03:54ZPreprint: 22 pages, 7 figures, 2 tablesMeasurement 246 (2025) 120140Eric ElzenheimerHartmut MatzJan ZerfowskiPaul AndersMichael HöftRobert RiegerSurjo R. SoekadarStephen RobinsonSilvia Knappe-Grüneberg10.1016/j.measurement.2025.120140http://arxiv.org/abs/2509.22128v1Machine Learning-based beam delivery time model for Mevion 250i with Hyperscan technology2025-09-26T09:50:41ZPurpose: Accurate prediction of beam delivery time (BDT) is essential for operational efficiency, 4D dose calculations, and advanced proton therapy techniques. Despite its importance, no machine-specific BDT model exists for Mevion systems.
Methods: We developed the first machine learning-based BDT model for the Mevion S250i Hyperscan system. Institutional machine log files from 11 patients (1120 files) were used to extract features including spot position, energy layer changes, Adaptive Aperture (AA) movements, and spot charge. Inter-pulse time ($Δ$T) was the target variable. A Random Forest model was trained with cross-validation and tested on held-out data. SHAP (Shapley Additive Explanations) analysis was used to quantify feature contributions.
Results: The model achieved mean absolute errors (MAE) ranging from 0.9 ms for short intervals (<50 ms) to 222 ms for long delays (>1000 ms). AA movements were the dominant global predictor for $Δ$T > 50 ms, while spot positions and pulse charge influenced short intervals. Energy changes had minor global impact but locally contributed to large $Δ$T values, consistent with range modulator physics. The model was tested in two clinical applications: volumetric repainting and 4D dose recalculation for interplay evaluation. Predicted cumulative delivery times deviated by only -1.7% from machine log data, and dosimetric metrics (D98, D95, V95) remained within intrinsic delivery variability.
Conclusions: This study presents the first machine-specific BDT model for the Mevion S250i, accurately capturing temporal dynamics and predictive performance. SHAP analysis provided insight into system behavior, highlighting the roles of AA adjustments, energy switching, and spot positioning. The model supports applications in interplay assessment, 4D dose calculation, and delivery time-based plan optimization.2025-09-26T09:50:41Z28 pages, 6 figuresGiorgio CartechiniFrancesco Giuseppe CordoniMirko UnipanIlaria Rinaldi10.1016/j.ijpt.2026.101301http://arxiv.org/abs/2509.22090v1Characterization and virtualization of a medical ultrasound transducer2025-09-26T09:11:59ZWith the rise of data-driven ultrasound imaging technologies, realistic simulation of ultrasound fields and radio-frequency data is becoming increasingly important. Accurate transducer characterization is crucial for realistic simulations. In this work, we present a streamlined ultrasound characterization pipeline that creates a virtual transducer model from acoustic holography measurements of the ultrasound field. The pipeline enables the extraction of the transmit impulse response, the receive impulse response, the size of the transducer aperture, and the focal distance of the lens. The method relies on acoustic field projections using either the angular spectrum method or Rayleigh integrals. Additionally, we present a method to compensate for misalignment in the measurement setup, based on the angular spectrum of the holographic measurement. We demonstrate the application of the characterization pipeline to a P4-1 phased array transducer. The resulting virtual transducer model can be imported into the PROTEUS simulation software for the generation of physically realistic ultrasound fields and ultrasound radio-frequency data with arbitrary transmit settings. The characterization pipeline has been released as an open-source toolkit to enable the ultrasound community to perform transducer characterization with increased accuracy and efficiency.2025-09-26T09:11:59Z17 pages, 10 figures, submission for peer reviewNathan BlankenMichel VersluisGuillaume Lajoiniehttp://arxiv.org/abs/2509.21913v1EqDiff-CT: Equivariant Conditional Diffusion model for CT Image Synthesis from CBCT2025-09-26T05:51:59ZCone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy (IGRT). It provides real time visualization at low cost and dose. However, photon scattering and beam hindrance cause artifacts in CBCT. These include inaccurate Hounsfield Units (HU), reducing reliability for dose calculation, and adaptive planning. By contrast, computed tomography (CT) offers better image quality and accurate HU calibration but is usually acquired offline and fails to capture intra-treatment anatomical changes. Thus, accurate CBCT-to-CT synthesis is needed to close the imaging-quality gap in adaptive radiotherapy workflows.
To cater to this, we propose a novel diffusion-based conditional generative model, coined EqDiff-CT, to synthesize high-quality CT images from CBCT. EqDiff-CT employs a denoising diffusion probabilistic model (DDPM) to iteratively inject noise and learn latent representations that enable reconstruction of anatomically consistent CT images. A group-equivariant conditional U-Net backbone, implemented with e2cnn steerable layers, enforces rotational equivariance (cyclic C4 symmetry), helping preserve fine structural details while minimizing noise and artifacts.
The system was trained and validated on the SynthRAD2025 dataset, comprising CBCT-CT scans across multiple head-and-neck anatomical sites, and we compared it with advanced methods such as CycleGAN and DDPM. EqDiff-CT provided substantial gains in structural fidelity, HU accuracy and quantitative metrics. Visual findings further confirm the improved recovery, sharper soft tissue boundaries, and realistic bone reconstructions. The findings suggest that the diffusion model has offered a robust and generalizable framework for CBCT improvements. The proposed solution helps in improving the image quality as well as the clinical confidence in the CBCT-guided treatment planning and dose calculations.2025-09-26T05:51:59Z12 pages, 8 figures, 3 tables, submitted to IEEE Transactions on Radiation and Plasma Medical SciencesAlzahra AltalibChunhui LiAlessandro Perellihttp://arxiv.org/abs/2509.21669v1Causal Machine Learning Analysis of Empirical Relative Biological Effectiveness (RBE) for Mandible Osteoradionecrosis in Head and Neck Cancer Radiotherapy2025-09-25T22:37:57ZMandible Osteoradionecrosis (ORN) is one of the most severe adverse events (AEs) for head and neck (H&N) cancer radiotherapy. Previous retrospective investigations on real-world data relied on conventional statistical models that primarily elucidate correlation rather than establishing causal relationships. Through the novel causal machine learning, we aim to obtain empirical relative biological effectiveness (RBE) for ORN in H&N cancer patients treated with pencil-beam-scanning proton therapy (PBSPT). 335 patients treated by PBSPT and 931 patients treated by volumetric-modulated arc therapy (VMAT) were included. We use 1:1 case-matching to minimize the imbalance in clinical factors between PBSPT and VMAT. The bias test of standardized mean differences (SMD) was applied on the case-matched patient cohorts. The causal machine learning method, causal forest (CF), was adopted to investigate the causal effects between dosimetric factors and the incidence of ORN. The dose volume constraints (DVCs) for VMAT and PBSPT were derived based on causal effects. RBE values were further empirically derived based on tolerance curves formed from DVCs. 335 VMAT patients were case-matched to 335 PBSPT patients; however, SMD analysis revealed persistent covariate imbalances within each group, indicating residual confounding influence. Using CF modeling, we identified DVCs of mandible ORN and found that PBSPT had lower critical volumes than those of VMAT, leading to empirical RBE exceeding 1.1 in the moderate dose range (1.61 at 40 Gy[RBE=1.1], 1.30 at 50 Gy, and 1.13 at 60 Gy). This study presents a novel application of causal machine learning to evaluate mandible ORN in radiotherapy. The results indicate that proton RBE may significantly exceed 1.1 in the moderate dose range, underscoring the importance of incorporating the variable RBE into PBSPT treatment planning to mitigate the risk of ORN.2025-09-25T22:37:57ZJingyuan ChenZhong LiuYunze YangOlivia M. MullerZhengliang LiuTianming LiuLei ZengRobert L. FooteDaniel J. MaSamir H. PatelWei Liu