https://arxiv.org/api/9irmeBJXUVY4O3Dw0qhKmBPZhUM 2026-09-10T23:33:19Z 9200 90 15 http://arxiv.org/abs/2606.18990v2 Quantitative Multi-Modal Optical Coherence Photoacoustic Elastography 2026-08-14T16:02:59Z We present a novel multi-modal optical coherence photoacoustic elastography framework, which combines two imaging modalities, optical coherence tomography and photoacoustic tomography, to enable complementary absorption-scattering measurements for the extraction of quantitative tissue features via quasi-static elastography. For this, we develop a sophisticated hybrid inversion algorithm for merging the complementary information layers contained in both optical coherence and photoacoustic-based elastography measurements, and perform systematic evaluations to assess the impact of hybrid elastography data on strain and stiffness reconstructions. An extension to a photoacoustic tomography and optical coherence tomography imaging system allows precise elastographic experiments. Studies on a silicone elastomer phantom demonstrate that the combined optical coherence - photoacoustic approach outperforms single-modality optical coherence elastography and photoacoustic elastography, yielding higher strain signal-to-noise ratios and improved stiffness estimates. These results establish the advantage of multi-modal complementary imaging and data merging for accurate, high-resolution elastographic strain and stiffness mapping in both scattering and absorbing materials. 2026-06-17T12:12:11Z 10 pages, 10 figures, 2 tables Ekaterina Sherina Lisa Krainz Wolfgang Drexler Otmar Scherzer http://arxiv.org/abs/2607.03286v2 Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations 2026-08-14T15:52:17Z Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation. 2026-07-03T12:53:44Z Charlie Aird-Rossiter Kadir Şimşek Maëliss Jallais Derek K. Jones Lida Kanari Marco Palombo http://arxiv.org/abs/2608.14213v1 MRI-guided cardiac radiotherapy using a 1.5 T MR-linac: surveying emerging patterns of care 2026-08-14T11:43:02Z Background: Cardiac tumours are rare and treated by surgical resections, which are complex, invasive and carry procedural risks. MRI-guided radiotherapy (MRgRT) noninvasively facilitates conformal dose deliveries using soft-tissue imaging and adaptive radiotherapy techniques. Aim: To assess the application of MRgRT for cardiac tumours, we conducted a patterns-of-care analysis with users of the 1.5T MR-linac. Materials & methods: A survey was distributed to users of the 1.5T MR-linac that treated patients with cardiac tumours. The survey included 30 questions concerning the patient cohort, imaging, treatment planning/simulation, radiotherapy treatment and treatment outcome. Results: Users from six international institutes completed the survey reporting twelve cardiac MRgRT treatments between 2021-2024. The median age[range] of the patients was 59[16-81] years with 50% of the cases concerning the treatment of primary tumours. The prescribed dose ranged between 30-60 Gy, with 30 Gy being prescribed the most (59%). In 75% of the cases, the treatment plans were delivered in five fractions with 6-8 Gy per fraction. Daily images were acquired with T1- and T2-weighted MRI and respiratory motion monitoring was performed in 92% of the cases using cine imaging. A single case was treated with intrafraction motion management using a novel vendor-provided gating solution on the MR-linac. Treatment outcomes were reported for 50% of the cases. All, but one case, attained local control using MRgRT without serious adverse events (grade$\geq$3). Conclusion: This study provides real-world insights into the feasibility and early outcomes to aid the development of cardiac MRgRT treatment recommendations and protocol harmonization. 2026-08-14T11:43:02Z O. Akdag S. Mandija J. Pomp M. P. W. Intven X. Chen J. Yang S. Oh M. Trombetta H. Tan J. De Leon M. Jameson E. Efe C. Önal M. F. Fast http://arxiv.org/abs/2608.14139v1 Birth of the Coil: another Milestone towards a fully reproducible low-field MRI scanner for head-imaging 2026-08-14T09:46:05Z Low-field magnetic resonance imaging (MRI) provides an accessible, portable, and low-cost alternative to high-field scanners, expanding diagnostic imaging to point-of-care settings. However, widespread adoption is fundamentally hindered by a severely reduced signal-to-noise ratio (SNR). At low frequencies, radiofrequency (RF) coil conductor losses - rather than tissue sample losses - predominantly govern the system's total noise, making meticulous RF coil optimization critical to recovering image quality. This work presents an open-source, optimized solenoid head coil tailored for the 50 mT open-source scanner (OSII ONE v2.1). The paper validates production reproducibility across three independent international institutions and introduce an open-source connector with integrated digital circuitry for coil identification and DC or logic signals. Comprehensive benchtop measurements, Electromagnetic Interference (EMI) coupling analysis, Specific Absorption Rate (SAR) safety simulations, and phantom and human volunteer imaging confirm the design's efficacy, safety, and reproducibility. The results of the paper, when combined with the material provided in the open-source dedicated repositories, set the basis for a fully reliable and reproducible component for the open-source OSII ONE MRI scanner. In addition, the same optimization strategy and design material can be exploited for designing other RF coils for imaging of other body parts. 2026-08-14T09:46:05Z Umberto Zanovello Julia Pfitzer Ariane Ernst Joshua Harper Jack Hayhoe Tri Nguyen Lukas Winter Nicola De Zanche http://arxiv.org/abs/2608.13919v1 Focal-point scanning for dose delivery and optimization with focused laser-accelerated very-high-energy electron beams 2026-08-14T03:41:59Z Focused very-high-energy electron (VHEE) beams can produce localized dose enhancement at selected depths, but irradiation of a finite target requires coordinated control of multiple focal positions, incidence directions, and beam weights while limiting exposure of nearby organs at risk (OARs). We present Focal-Point Scanning (FPS), a dose delivery and optimization method developed for laser wakefield accelerator (LWFA)-driven VHEE beams. The method is based on a two-dipole focusing system that produces single-plane beam convergence and allows the focal position to be varied by changing the magnetic field strength. FPS distributes focal points throughout the planning target volume and determines focal-point-specific incidence sectors according to the geometry of nearby critical OARs. The method was evaluated using the AAPM TG119 C-shape benchmark and one previously treated lung radiotherapy case. At matched target coverage, FPS reduced the TG119 Core mean dose by approximately one half relative to parallel VHEE and intensity-modulated x-ray plans, approaching the single-field proton pencil-beam-scanning reference. In the lung case, FPS maintained target coverage comparable to the clinical volumetric modulated arc therapy reference while reducing the mean dose to every evaluated OAR; spinal-cord mean and maximum doses decreased by 93.2% and 87.2%, respectively. The evaluated OAR mean doses varied little across rms energy spreads of 0 to 10% and for a flat-top electron spectrum spanning 150 to 250 MeV. These results demonstrate that focal-point-specific angular selection can translate focused-beam physics into effective OAR sparing and support FPS as a planning strategy for broadband LWFA-VHEE radiotherapy. 2026-08-14T03:41:59Z 31 pages, 18 figures Zhiyuan Guo Yifei Pi Junwei Zhou Guoqing Liu Wenbo Zhang Haiyang Wang Yaping Qi Xiaoming Guo Yuhan Zhang Bo Peng Jianfei Hua Yang Wan Wei Lu http://arxiv.org/abs/2608.13807v1 Label-Free Deep-Tissue Peripheral Nerve Detection with a Handheld Multimodal OCT Probe and NerveDetNet 2026-08-13T22:34:46Z Peripheral nerves buried beneath intact tissue are difficult to visualize during surgery and remain inaccessible to white light wide-field imaging and other surface optical imaging methods. Existing OCT nerve studies have largely relied on exposed nerves or polarization contrast with limited depth penetration, restricting their value for subsurface intraoperative guidance. Here, we introduce, to our knowledge, the first label-free framework for detecting peripheral nerves beneath unopened tissue and resolving their depth using intensity-based OCT structural signatures alone. The framework combines a handheld multimodal probe, integrating swept-source OCT with co-registered white light and autofluorescence imaging, with a ``confirm-then-capture'' workflow designed for practical surgical use. To enable efficient analysis of sparsely sampled OCT volumes, we develop NerveDetNet, a lightweight 2.5D segmentation network that recovers weak and spatially displaced nerve signals by incorporating spatial context, frame-order information, and shift-tolerant correlations across frames through a dedicated nerve feature correlation module. In ex vivo tissue experiments, NerveDetNet consistently outperformed six representative 2D baselines across all frame spacings, achieving a Dice score of 0.725 under the sparsest sampling condition while using approximately half the model parameters. End-to-end validation demonstrated localization of nerves invisible at the surface and depth-resolved detection up to 1.3--1.4~mm below the tissue surface, with OCT derived depth maps overlaid directly onto the surgical view. Together, these results establish a practical label-free approach for subsurface nerve visualization that supports intraoperative compatibility, enables efficient sparse-volume analysis, and provides depth-resolved guidance without tissue opening, contrast agents, or nerve exposure. 2026-08-13T22:34:46Z Yihan Wang Ruilin You Shaobai Li Jiabin Chen Bofan Song Anh D. Le Rongguang Liang http://arxiv.org/abs/2603.15070v2 Hamiltonian dynamics for stochastic reconstruction in emission tomography 2026-08-13T20:53:51Z Objective: To develop a practical stochastic reconstruction framework for emission tomography that generates ensembles of data-compatible images and enables uncertainty quantification and assessment of forward-model adequacy. Approach: The framework combines stochastic-gradient descent initialization with Hamiltonian Monte Carlo (HMC) sampling directly in high-dimensional voxel space. Beyond point reconstruction, we introduce a spatially resolved operator-weighted diagnostic, the sampled data-visible variance, which quantifies how image fluctuations propagate through the imaging operator and thereby probes the local conditioning of the inverse problem under realistic acquisition physics. The methodology is evaluated using controlled software phantoms, experimental anthropomorphic phantom measurements, and a clinical DATSCAN SPECT acquisition. Main results: Under ideal conditions, the HMC ensemble mean provides point-estimate accuracy comparable to deterministic reconstruction methods, while the sampled ensemble provides additional physically interpretable information. The ensemble analysis helps distinguish uncertainty associated with the intrinsic ill-posedness of the inverse problem from variability linked to forward-model inadequacy. The clinical example demonstrates applicability under realistic acquisition statistics rather than diagnostic performance. Significance: The proposed stochastic reconstruction framework provides a practical ensemble-based approach for emission tomography that extends conventional point reconstruction with model-conditioned uncertainty estimates and spatially resolved diagnostics of forward-model adequacy. 2026-03-16T10:25:08Z 33 pages, 12 figures T. Leontiou A. Frixou E. Ttofi C. Chrysostomou Y. Parpottas K. Michael S. Frangos E. Stiliaris C. N. Papanicolas http://arxiv.org/abs/2608.13106v1 Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM 2026-08-13T11:34:35Z Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay. 2026-08-13T11:34:35Z Vishal Kumar Andreas Jehle Tizian Lorenzen Julika Radecke Knut Müller-Caspary Massimo Kube Henning Stahlberg http://arxiv.org/abs/2608.12656v1 4$π$ Planning for the Reduction of Predicted Hematologic Toxicity Risk in Cervical Cancer Radiotherapy 2026-08-12T23:40:03Z Purpose: In conventional coplanar radiotherapy for cervical cancer, nearby pelvic bones receive high radiation doses, increasing the risk of acute hematologic toxicity (HT). This study aims to estimate the HT risk reduction achievable with non-coplanar (4$π$) radiotherapy. Methods: We retrospectively analyzed 114 cervical cancer patients treated with coplanar volumetric modulated arc therapy (VMAT) between 2021 and 2023. Radiomic features from planning CTs were extracted and combined with clinical and dosimetric data to train predictive machine learning models. Patients were then replanned using integrated non-coplanar beam orientation and fluence map optimization (4$π$ planning). The top performing model was applied to these new plans to evaluate potential HT reduction. Results: Models combined radiomics, clinical, and dosimetric features achieved the highest predictive performance (AUC = 0.79). Feature importance analysis highlighted CT radiomic and dosimetric variables as the strongest predictors. Compared to VMAT, 4$π$ non-coplanar planning significantly reduced doses to the bone marrow (V10Gy, V20Gy, V30Gy, and V40Gy by 28%, 52%, 47%, and 33%, respectively) while significantly reducing dose to other pelvic organs at risk (OAR). When evaluated by the model, this improved dosimetry translated into a 23% reduction in predicted HT risk (risk ratio: 0.77; 95% CI: 0.75-0.79 and odds ratio: 0.68; 95% CI:0.65-0.71). Conclusions: Non-coplanar 4$π$ radiotherapy significantly lowers radiation doses to major pelvic bones during cervical cancer treatment without compromising target coverage or sparing of other OARs. Based on our predictive model, this superior dosimetry should translate to a marked reduction in acute hematologic toxicity. 2026-08-12T23:40:03Z Haotian Feng Yan Kong Qifan Xu Ke Sheng http://arxiv.org/abs/2608.12169v1 Reducing Spectral Oscillations for Robust Reference Frequency-Based Ultrasound Attenuation Estimation in Harmonic Imaging 2026-08-12T15:28:24Z Ultrasound attenuation coefficient estimation (ACE) has emerged as a quantitative imaging biomarker for noninvasive assessment of hepatic steatosis. A system-independent technique based on spectral normalization, known as the reference frequency method (RFM), was previously proposed to estimate ACE without requiring a well-calibrated reference phantom. Furthermore, incorporating harmonic imaging can significantly suppress reverberation signals. In previous clinical study, RFM has achieved high correlation with MRI-PDFF, demonstrating its potential for clinical application. However, a major challenge of RFM is the presence of oscillations in the frequency power-ratio decay curves (FPDCs), which can distort the linear fitting used to estimate the attenuation coefficient and consequently degrade ACE accuracy. These oscillations arise from constructive and destructive interference among backscattered echoes, resulting in oscillatory fluctuations in the measured power spectrum that propagate into the FPDCs. We propose a transmission scheme combining multiple frequencies and steering angles to mitigate oscillations in the FPDCs. Averaging these FPDCs suppresses the interference-induced oscillations while preserving the attenuation-dependent decay trend, thereby improving linearity and the accuracy of ACE results. In in-vitro experiments using calibrated phantoms (0.5 and 0.76 dB/cm/MHz) demonstrated that the proposed method improved FPDC linearity and ACE accuracy, achieving an R2 of 0.99 and attenuation coefficient estimates of 0.51 and 0.77 dB/cm/MHz, versus an R2 of 0.89 and estimates of 0.56 and 0.70 dB/cm/MHz for conventional RFM. The proposed method also demonstrated superior performance in a pilot patient study (n=15), achieving a stronger correlation with MRI-PDFF (R = 0.89 vs. 0.83) while reducing inter-measurement variability, indicating improved robustness and clinical potential. 2026-08-12T15:28:24Z U-Wai Lok Jingke Zhang Chengwu Huang Tao Wu Jieyang Jin Ryan M. DeRuiter Jingyi Yin Lijie Huang Yanzhe Zhao Kaipeng Ji Kate M. Knoll Dawn Boynton Kymberly D. Watt Kathryn A. Robinson Joshua D. Trzasko Matthew Callstrom Shigao Chen http://arxiv.org/abs/2608.11989v1 Bridging the gap: Using deep learning to reconstruct noise-reduced super-resolved OCT images from gapped spectra 2026-08-12T12:27:11Z Fourier-domain (FD) optical coherence tomography (OCT) depends on broadband sources to maximize axial resolution and image quality. However, these lasers significantly drive device cost or may be unavailable at desired wavelength and bandwidth ranges. A potential solution lies in integrating multiple, more affordable sources with lower individual bandwidth into a single system. However, difficulties arise if the resulting spectrum exhibits discontinuities. In this letter, we present a method that can combine OCT images from a flexible number of spectra with arbitrary, possibly non-overlapping gaps using a neural network. Compared to low-resolution input images, reconstructed B-scans are super-resolved, preserve even fine and low-contrast details and edges, and exhibit strong noise reduction that increases with the band gap. The proposed method could thereby provide a major step towards high-quality OCT imaging using spectrally disjoint, low-bandwidth sources. In broadband settings, it can be directly applied as a Fourier-domain masked autoencoder for self-supervised image quality enhancement. 2026-08-12T12:27:11Z Submitted to Optica Jonas Nienhaus Medical University of Vienna Thomas Schlegl Medical University of Vienna Wolfgang Drexler Medical University of Vienna Tilman Schmoll Carl Zeiss Meditec AG Rainer A. Leitgeb Medical University of Vienna http://arxiv.org/abs/2608.11117v1 T1, T2, and complex permittivities of hydrogels, paramagnetic salt solutions, and oils at 0.35, 1.5, and 3 Tesla 2026-08-11T16:24:20Z Approach: The T1, T2, and complex permittivities of candidate MRI phantom constituents (hydrogels, paramagnetic electrolytes, and oils) were measured at different magnetic field strengths and concentrations. Data: T1 decreased with increasing concentration except for PEG. The T1 and T2 relaxivities of polyethylene glycol (PEG), polyvinylpyrrolidone (PVP), sodium polyacrylate, and deionized water did not significantly vary with field strength. The T2 relaxivities of gelatin and sodium alginate did not significantly vary with field strength. All of the hydrogels and paramagnetic electrolyte solutions had high static dielectrics (e.g., εs~70) similar to water. The static electrical conductivities of Miller's LB agar, gelatin, PVA, sodium alginate, sodium polyacrylate, xanthan gum, CuSO4, NiCl2, and Mn(NO3)2 rose with concentration. However, the conductivities of PEG and PVP did not rise with concentration. Conclusions: Sodium polyacrylate, PVP, and PEG hydrogels are challenging for generating consistent phantoms. Sodium alginate, Miller's LB agar, and xanthan gum were good hydrogel candidates. Mn(NO3)2 had the highest relaxivities of the tested samples. All three oils (canola, castor, and grapeseed) are good candidates for low dielectric (εs<10) phantoms for high field applications) but with low conductivities. 2026-08-11T16:24:20Z 37 pages, 15 Tables, 23 Figures H Michael Gach Kerri Prinos Hannah Sechaga http://arxiv.org/abs/2604.02053v2 Terbium-149 PET/CT: First Quantitative Imaging with a Clinical Long-Axial Field-of-View Scanner 2026-08-11T10:26:28Z Introduction: Terbium-149 ($^{149}$Tb) is a promising radionuclide for targeted $α$ therapy that has a non-zero branching ratio (BR) for positron decay. However, its relatively low positron branching fraction and multiple prompt $γ$ emissions may challenge quantitative imaging. This study evaluates, for the first time, the imaging performance and quantitative accuracy of $^{149}$Tb using a clinical long axial field-of-view (LAFOV) PET/CT system. Methods: Quantitative accuracy of $^{149}$Tb was assessed with a NEMA IEC body phantom, which was filled with about 45 MBq $^{149}$Tb and a sphere-to-background ration of 10:1. The phantom was scanned for 20 min and shorter scan times and lower activities were simulated. Recovery coefficients, coefficient of variation, and lung residual error were evaluated for different reconstruction settings and compared to the EARL standard 2 for $^{18}$F. Results: High-quality PET images of $^{149}$Tb were obtained, even with a simulated total activity of 4.5 MBq. The 20 min and full activity scan yielded a mean recovery coefficient $RC_\textit{mean}$ of $0.55$, $0.69$, $0.73$, $0.76$, $0.79$, and $0.81$ for the six phantom spheres. Despite the low count statistics, the coefficient of variation stays mostly below $15\,\%$. Relative scatter correction combined with prompt $γ$ modeling provided robust quantification. Conclusion: $^{149}$Tb can be imaged using a commercial LAFOV PET/CT with a quantitative accuracy comparable to the EARL standard 2 for $^{18}$F. These findings demonstrate the feasibility of PET-based treatment verification and dosimetry for targeted $α$ therapy with $^{149}$Tb. 2026-04-02T13:53:23Z Lorenzo Mercolli Pascal V. Grundler Anzhelika N. Moiseeva Lars Eggimann Saverio Braccini Ulli Köster Nicholas P. van der Meulen http://arxiv.org/abs/2608.10429v1 Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA PET Synthesis in Prostate Cancer 2026-08-11T03:24:03Z Deep learning models that synthesize PET from CT or MRI can reduce patient dose and scanner demand, but are typically optimized with global losses such as L1 or mean squared error (MSE) that treat all voxels similarly. In whole-body PSMA-PET, tumor voxels occupy only a small fraction of the volume, yet carry the clinically relevant activity signal; as a result, models can achieve high structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) while still underestimating lesion activity or failing to preserve tumor-specific structure. Radiomics provides biologically meaningful descriptors of tumor intensity and texture, but direct radiomics conditioning is time-consuming because it requires feature extraction from delineated lesion regions. We propose LAFNO, a Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA-PET synthesis that replaces high-dimensional radiomics conditioning with two efficient CT-derived proxy channels. Motivated by radiomics analysis of PSMA-avid tumor core and peritumoral regions, LAFNO uses a contrast proxy for local density variation and a disorder proxy for local texture heterogeneity, both injected into the model bottleneck. LAFNO combines whole-volume reconstruction with lesion-level total lesion activity (TLA), tumor-core contrast, and peritumoral supervision. We evaluated LAFNO against four baseline architectures on the TCIA PSMA-PET-CT-Lesions dataset. LAFNO remained competitive on whole-volume image quality, achieving SSIM of 0.960 and 0.938 for 18F- and 68Ga-PSMA, respectively, while reducing per-patient TLA error to 48.3% and 64.0% for 18F- and 68Ga-PSMA, respectively, and achieving the highest tumor-core radiomics reproducibility across all feature classes for both tracers. Peritumoral reproducibility remained tracer-dependent, indicating that biological fidelity in synthetic PSMA-PET remains challenging. 2026-08-11T03:24:03Z Rashmi Bhaskara Waleed M. Almutairi Matthew Gopaulchan Maram Musaad Alqurashi Francis Asamoah Alex Ocana Clinton D. Bahler Oluwaseyi M. Oderinde http://arxiv.org/abs/2608.10343v1 ENCORE: Efficient Noise Context-Aware Representation for Low-Dose CT Denoising 2026-08-11T00:57:39Z While deep learning-based denoising has become widely adopted in low-dose CT, conventional models use generic architectures designed for natural images, failing to account for non-stationary and spatially correlated CT noise characteristics. To address this, we propose an Efficient Noise COntext-aware REpresentation (ENCORE) framework that explicitly leverages CT noise characteristics and anatomical features. First, we reformulate the noise synthesis procedure based on a realistic noise distribution beyond the conventional Gaussian approximation, establishing a rigorous foundation for training pair generation. Next, we extract local noise power and correlation contexts to guide the denoising process. To fully leverage the potential of noise context, we propose a FlyingConv module, which adaptively changes convolution weights for each local image region. Notably, our approach demonstrates substantial gains in both denoising quality and computational efficiency. Furthermore, manipulating the intensity of the noise context maps at inference time enables zero-shot conditional denoising, allowing for dynamic control over the output image texture. The entire pipeline is available at https://github.com/minwoo-yu/ENCORE.git 2026-08-11T00:57:39Z Minwoo Yu N. Robert Bennett Jongduk Baek Adam S. Wang