https://arxiv.org/api/FE+bldqAU8iy/nOE2CLr1/Ul42o2026-06-25T21:43:22Z900788515http://arxiv.org/abs/2507.19636v2Multisession Longitudinal Dynamic MRI Incorporating Patient-Specific Prior Image Information Across Time2025-10-03T21:22:58ZSerial Magnetic Resonance Imaging (MRI) exams are often performed in clinical practice, offering shared anatomical and motion information across imaging sessions. However, existing reconstruction methods process each session independently without leveraging this valuable longitudinal information. In this work, we propose a novel concept of longitudinal dynamic MRI, which incorporates patient-specific prior images to exploit temporal correlations across sessions. This framework enables progressive acceleration of data acquisition and reduction of scan time as more imaging sessions become available. The concept is demonstrated using the 4D Golden-angle RAdial Sparse Parallel (GRASP) MRI, a state-of-the-art dynamic imaging technique. Longitudinal reconstruction is performed by concatenating multi-session time-resolved 4D GRASP datasets into an extended dynamic series, followed by a low-rank subspace-based reconstruction algorithm. A series of experiments were conducted to evaluate the feasibility and performance of the proposed method. Results show that longitudinal 4D GRASP reconstruction consistently outperforms standard single-session reconstruction in image quality, while preserving inter-session variations. The approach demonstrated robustness to changes in anatomy, imaging intervals, and body contour, highlighting its potential for improving imaging efficiency and consistency in longitudinal MRI applications. More generally, this work suggests a new context-aware imaging paradigm in which the more we see a patient, the faster we can image.2025-07-25T19:09:54ZJingjia ChenHersh ChandaranaDaniel K. SodicksonLi Fenghttp://arxiv.org/abs/2510.03488v1Scintillator-integrated microchannel plate photomultiplier tubes for ultrafast timing over keV-GeV energy scales2025-10-03T20:08:15ZPrecise measurement of radiation has long played a vital role in a wide range of research and industrial fields, from fundamental physics beyond the Standard Model to medical imaging such as time-of-flight positron emission tomography. Developing radiation detectors that achieve high timing precision-on the order of a few tens of picoseconds-and energy measurement capabilities remains indispensable yet challenging. In this study, we developed two types of scintillator-integrated microchannel plate photomultiplier tubes (SCI-IMPs), one incorporating barium fluoride, and the other bismuth germanate, to enable simultaneous high-precision timing and energy measurements. To evaluate their performance over a wide energy range from keV- to GeV-scale, electron-positron annihilation gamma rays and cosmic ray muons were used. For energy measurements, both detectors achieved an energy resolution of approximately 35% at 511 keV. For timing measurements using 511 keV, coincidence time resolutions (CTRs) of approximately 50 ps full width at half maximum (FWHM) were obtained for both detectors. In contrast, for cosmic ray muon experiments where cosmic ray muon energy is typically on the order of GeV, CTRs were measured to be 25.1 and 16.8 ps FWHM for barium fluoride- and bismuth germanate-based detectors, respectively. The versatile scintillator-integration technique established in this study can broaden the applicability of the newly developed SCI-IMPs. In particular, these results demonstrate that the developed detectors push the boundaries of timing performance while retaining energy measurement and hold promise for future applications in fundamental physics experiments and medical imaging.2025-10-03T20:08:15Z15 pages, 11 figure2Ryosuke OtaYuya OnishiDaehee LeeYuki IchikawaKoji KuramotoKenshi ShimanoYutaka HasegawaEric BergTakahiro MoriyaSimon R. CherrySun Il Kwonhttp://arxiv.org/abs/2510.03431v1Application of a Virtual Imaging Framework for Investigating a Deep Learning-Based Reconstruction Method for 3D Quantitative Photoacoustic Computed Tomography2025-10-03T18:49:51ZQuantitative photoacoustic computed tomography (qPACT) is a promising imaging modality for estimating physiological parameters such as blood oxygen saturation. However, developing robust qPACT reconstruction methods remains challenging due to computational demands, modeling difficulties, and experimental uncertainties. Learning-based methods have been proposed to address these issues but remain largely unvalidated. Virtual imaging (VI) studies are essential for validating such methods early in development, before proceeding to less-controlled phantom or in vivo studies. Effective VI studies must employ ensembles of stochastically generated numerical phantoms that accurately reflect relevant anatomy and physiology. Yet, most prior VI studies for qPACT relied on overly simplified phantoms. In this work, a realistic VI testbed is employed for the first time to assess a representative 3D learning-based qPACT reconstruction method for breast imaging. The method is evaluated across subject variability and physical factors such as measurement noise and acoustic aberrations, offering insights into its strengths and limitations.2025-10-03T18:49:51ZPreprint submitted to Elsevier PhotoacousticsRefik Mert CamSeonyeong ParkUmberto VillaMark A. Anastasiohttp://arxiv.org/abs/2410.14499v2Ultrasound matrix imaging for 3D transcranial in vivo localization microscopy2025-10-03T08:43:20ZTranscranial ultrasound imaging is usually limited by skull-induced attenuation and high-order aberrations. By using contrast agents such as microbubbles in combination with ultrafast imaging, not only can the signal-to-noise ratio be improved, but super-resolution images down to the micrometer scale of the brain vessels can also be obtained. However, ultrasound localization microscopy (ULM) remains affected by wavefront distortions that limit the microbubble detection rate and hamper their localization. In this work, we show how ultrasound matrix imaging, which relies on the prior recording of the reflection matrix, can provide a solution to these fundamental issues. As an experimental proof of concept, an in vivo reconstruction of deep brain microvessels is performed on three anesthetized sheep. The compensation of wave distortions is shown to markedly enhance the contrast and resolution of ULM. This experimental study thus opens up promising perspectives for a transcranial and nonionizing observation of human cerebral microvascular pathologies, such as stroke.2024-10-18T14:30:25Z60 pages, 16 figures, 3 tablesSci. Adv.11, eadt9778, 2025Flavien BureauLouise DenisAntoine CoudertMathias FinkOlivier CoutureAlexandre Aubry10.1126/sciadv.adt9778http://arxiv.org/abs/2510.06241v1multimodars: A Rust-powered toolkit for multi-modality cardiac image fusion and registration2025-10-03T08:09:35ZCombining complementary imaging modalities is critical to build reliable 3D coronary models: intravascular imaging gives sub-millimetre resolution but limited whole-vessel context, while CCTA supplies 3D geometry but suffers from limited spatial resolution and artefacts (e.g., blooming). Prior work demonstrated intravascular/CCTA fusion, yet no open, flexible toolkit is tailored for multi-state analysis (rest/stress, pre-/post-stenting) while offering deterministic behaviour, high performance, and easy pipeline integration. multimodars addresses this gap with deterministic alignment algorithms, a compact NumPy-centred data model, and an optimised Rust backend suitable for scalable, reproducible experiments. The package accepts CSV/NumPy inputs including data formats produced by the AIVUS-CAA software2025-10-03T08:09:35ZAnselm W. StarkMarc IlicAli MokhtariPooya Mohammadi KazajChristoph GraeniIsaac Shirihttp://arxiv.org/abs/2509.01833v2Radial spoke energy for self-navigated motion detection and position-ordered dynamic musculoskeletal MRI2025-10-02T19:50:57ZMotion remains a key challenge in MRI, as both involuntary (e.g., head motion) and voluntary (e.g., joint motion) movement can degrade image quality or provide opportunities for dynamic assessment. Existing motion sensing methods, such as external tracking or navigator sequences, often require additional hardware, increase SAR, or demand sequence modification, which limits clinical flexibility. We propose a computationally efficient, self-navigated motion sensing technique based on spoke energy derived from 3D radial k-space data. Using the Fourier Slice and Parseval's theorems, spoke energy captures object-coil alignment and can be computed without altering the sequence. A sliding window summation improves robustness, and a second principal component analysis (2ndPCA) strategy yields a unified motion-sensitive signal. Beyond conventional head motion correction, we demonstrate the novel application of this method in enhancing dynamic 4D MRI of the ankle and knee under a continuous movement protocol. By sorting spokes based on position rather than time, we achieve motion-resolved reconstructions with improved anatomical clarity. This approach enables real-time motion detection and supports broader adoption of motion-aware dynamic MRI.2025-09-01T23:25:00Z18 pages, 8 figures. supplementary MP4 file as a ancillary file located in the anc directoryEnping LinFatih CalakliMusa Tunç ArslanGiovani Schulte FarinaSimon Keith Warfieldhttp://arxiv.org/abs/2510.02482v1Surface Acoustic Wave Hemolysis Assay for Evaluating Stored Red Blood Cells2025-10-02T18:38:20ZBlood transfusion remains a cornerstone of modern medicine, saving countless lives daily. Yet the quality of transfused blood varies dramatically among donors-a critical factor often overlooked in clinical practice. Rapid, benchtop, and cost-effective methods for evaluating stored red blood cells (RBCs) at the site of transfusion are lacking, with concerns persisting about the association between metabolic signatures of stored RBC quality and transfusion outcomes. Recent studies utilizing metabolomics approaches to evaluate stored erythrocytes find that donor biology (e.g., genetics, age, lifestyle factors) underlies the heterogeneity associated with blood storage and transfusion. The appreciation of donor-intrinsic factors provides opportunities for precision transfusion medicine approaches for the evaluation of storage quality and prediction of transfusion efficacy. Here we propose a new platform, the Surface Acoustic Wave Hemolysis Assay (SAW-HA), for on-site evaluation of stored RBCs utilizing SAW Hemolysis Temperature (SAWHT) as a marker for RBC quality. We report SAWHT as a mechanism-dependent reproducible methodology for evaluating stored human RBCs up to 42 days. Our results define unique signatures for SAW hemolysis and metabolic profiles in RBCs from two of the six donors in which high body mass index (BMI) and RBC triglycerides associated with increased susceptibility to hemolysis. Metabolic age of the stored RBCs - a recently appreciated predictor of post-transfusion efficacy-reveal that RBCs from the two low SAWHT units were characterized by disrupted redox control, deficient tryptophan metabolism, and high BMI. Together, these findings indicate the potential of the SAW-HA as a point-of-care analysis for transfusion medicine.2025-10-02T18:38:20ZMeiou SongColin C. AndersonNakul SridharJulie A. ReiszLeyla AkhYu GaoAngelo D'AlessandroXiaoyun Dinghttp://arxiv.org/abs/2510.02478v1Acoustic Probing of New Biomarkers for Rapid Sickle Cell Disease Screening2025-10-02T18:36:02ZSickle cell disease (SCD) remains a critical global health issue, with high child mortality in low-resource regions. Early screening and diagnosis is essential for improving health outcomes, but conventional screening methods are unsuitable for widespread use due to the high costs of laboratory equipment. There is an urgent need for portable, cost-effective, and user-friendly point-of-care tools that can quickly assess blood health. Here, we explore two new biomarkers enabled by acoustic probing for rapid SCD screening: cell membrane stability from measuring red blood cell (RBC) lysis temperature in whole blood, and plasma protein concentration from measuring relative protein precipitation in blood plasma. Both biomarkers effectively differentiate healthy HbAA samples from pre-/no transfusion HbSS samples with high accuracy. Additionally, the RBC lysis biomarker can distinguish post-transfusion exchange HbSS samples with a lower percentage of sickled cells, indicating the potential to initially screen for milder forms of SCD as well as sickle cell trait.2025-10-02T18:36:02ZNakul SridharMeiou SongMichael H. B. StowellKathryn L. HassellXiaoyun Dinghttp://arxiv.org/abs/2510.01866v1In Situ Observation of Proton-Induced DNA Fragmentation in the Bragg Peak: Evidence for a Protective Role of Water2025-10-02T10:17:46ZWe report in situ single-molecule measurements of proton-induced double-strand breaks (DSBs) in DNA immersed in water, using real-time fluorescence tracking along the entire proton path, including the Bragg peak region. By chemically suppressing radical-mediated processes, we isolate direct DNA damage mechanisms and determine DSB cross sections as a function of depth. Near the Bragg peak, we observe a tenfold reduction in DSB cross sections in aqueous DNA compared to dry DNA, providing quantitative evidence for the protective role of water. These findings highlight the importance of intermolecular energy dissipation in mitigating radiation-induced damage in condensed biological matter, with implications for radiobiology and proton therapy modeling.2025-10-02T10:17:46ZPhysical Review Research 7, 043004 (2025)R. LiénardP. BarberetK. ChatzipapasG. DevèsT. DhôteT. GuérinH. SeznecF. Gobet10.1103/t6st-wwythttp://arxiv.org/abs/2510.00357v1Terahertz Quasi-BIC Metasurfaces for Ultra-Sensitive Biosensing and High-Speed Wireless Communications2025-09-30T23:41:46ZBound states in the continuum (BICs) have emerged as a revolutionary paradigm in terahertz (THz) photonics, enabling metasurfaces with theoretically infinite quality factors (Q-factors) and unprecedented light-matter control. This review synthesizes a decade of progress in THz-BIC research, tracing the evolution from foundational symmetry-protected designs to application-optimized quasi-BICs. We dissect multipolar origins, topological robustness, and symmetry-breaking strategies underpinning high-Q resonances, alongside computational frameworks for predictive design. The timeline highlights key milestones: early dielectric metasurfaces with high Q-factor, flexible biosensors achieving microgram detection limits, and Kerker-conditioned gas spectrometers reducing path lengths by few orders of magnitude. Emerging frontiers in reconfigurable MEMS-BICs and chiral quantum photonics are critically evaluated. Despite breakthroughs, scalability barriers persist for 6G integration, including nano-fabrication tolerances, material loss trade-offs, and dynamic control gaps. This review establishes BIC metasurfaces as pivotal enablers of compact, high-efficiency THz technologies poised to bridge the gap between fundamental discovery and commercialization of THz-based 6G communication and MedTech.2025-09-30T23:41:46ZIslam I. AbdulaalAbdelrahman W. A. ElsayedOmar A. M. Abdelraoufhttp://arxiv.org/abs/2510.17824v1Micromechanical characterisation of osteoarthritic subchondral bone by micropillar compression2025-09-30T19:22:48ZOsteoarthritis (OA) is a multifaceted joint disease which poses significant socioeconomic burdens and remains a significant clinical challenge. Evidence suggests that structural and mechanical changes in subchondral bone influence the pathogenesis and development of OA, leading to diminished bone quality and cartilage degeneration. While changes in microstructure and tissue scale elastic properties are well reported, the tissue yield response of subchondral bone in OA and their correlation with compositional changes have not been investigated. Here, we performed quasistatic micropillar compression and nanoindentation within the subchondral bone plate and trabeculae of hydrated non-diseased (ND) and OA affected specimens retrieved from the distal tibia in vivo. The micropillars, extracted by laser ablation, exhibited a taper angle which mandated the use of an in silico micropillar compression routine to back-calculate elastic modulus and strength of the bone tissue that comprised each micropillar. Elastic modulus remained unchanged between ND and OA subchondral bone, whereas strength increased from 46.0 MPa to 57.3 MPa in OA subchondral trabecular bone but not in the bone plate. Micropillar matched Raman spectroscopy and quantitative backscattered electron imaging revealed mineralisation is the underlying determinant of elastic modulus and strength at the microscale. By combining micromechanical and tissue compositional analyses, we investigated how the mechanical properties are related and how these properties are affected in subchondral bone by OA. Our results may be of value in the development and optimisation of interventions used to alleviate the socioeconomic burdens associated with this debilitating joint disease.2025-09-30T19:22:48ZSamuel McPheeMarta Peña FernándezLekha KoriaMarlène MengoniRainer J BeckJonathan D ShephardClaire BrockettUwe Wolframhttp://arxiv.org/abs/2510.00189v1A Virtual Imaging Framework for Three-Dimensional Quantitative Optoacoustic Tomography Using Stochastic Numerical Breast Phantoms2025-09-30T19:05:47ZOptoacoustic tomography (OAT) is a promising modality for breast cancer diagnosis because tumor angiogenesis and, potentially, hypoxia can be visualized using quantitative OAT (qOAT) techniques. Clinically meaningful inference generally requires accurate image reconstruction, which depends on measurement quality and the imager design. Virtual imaging offers a cost-effective alternative to experimental prototyping for system design evaluation and supports computational method development. This work presents a comprehensive virtual imaging framework for breast qOAT, extending a stochastic numerical breast phantom (NBP) generator by incorporating skin tone variation and both benign and malignant lesions. It enables end-to-end simulation, modeling transducer spatial and acousto-electric impulse responses. Its utility is demonstrated through a case study comparing two system designs. A total of 1,020 NBPs and associated measurement data have been made publicly available to accelerate research in optoacoustic and optical imaging. The framework provides a versatile platform for advancing computational methods and guiding system design optimization.2025-09-30T19:05:47ZSeonyeong ParkGangwon JeongUmberto VillaMark A. Anastasiohttp://arxiv.org/abs/2509.26400v1Real-time gait event detection using motion capture to control an electrical stimulator: Proof-of-concept2025-09-30T15:32:52ZCerebral palsy (CP) is the most prevalent motor disorder in childhood and often results in gait abnormalities that hinder mobility and diminish quality of life. Functional electrical stimulation (FES) has demonstrated potential in enhancing gait in individuals in this population, however, its practical implementation remains complex, as it requires monitoring various gait parameters and delivering personalized stimulation to different muscles in order to correct various gait impairments. Recent advancements in real-time motion capture (MOCAP) and wearable sensors now enable the development of closed-loop, multi-channel FES systems. This study will assess the feasibility and responsiveness of a real-time, event-triggered multi-channel stimulation protocol during treadmill walking. The stimulation is triggered by specific gait events (heel strike, knee flexion, ankle dorsiflexion) detected through the MOCAP system and administered via a multichannel electrical stimulator. Conducted on healthy adults, this preliminary study focuses on assessing technical feasibility. We report different technical outcomes including the latency between gait event detection and the appearance of stimulation artifacts in EMG signals. The results confirm the viability of the system, laying the groundwork for future clinical application in the rehabilitation of children with CP.2025-09-30T15:32:52ZFESWS 2025 - 15th Vienna International Workshop on Functional Electrical Stimulation \& 30 years IFESS Anniversary, Sep 2025, Vienne (Austria), AustriaGabriel GraffagninoCAMINDavid GasqToNIC, Comue de ToulouseKarine PatteCAMINBenoît SijobertCAMINChristine Azevedo CosteCAMINhttp://arxiv.org/abs/2509.26259v1Millennium Pathways for Tractography: 40 grand challenges to shape the future of tractography2025-09-30T13:46:21ZIn the spirit of the historic Millennium Prize Problems that heralded a new era for mathematics, the newly formed International Society for Tractography (IST) has launched the Millennium Pathways for Tractography, a community-driven roadmap designed to shape the future of the field. Conceived during the inaugural Tract-Anat Retreat, this initiative reflects a collective vision for advancing tractography over the coming decade and beyond. The roadmap consists of 40 grand challenges, developed by international experts and organized into seven categories spanning three overarching themes: neuroanatomy, tractography methods, and clinical applications. By defining shared short-, medium-, and long-term goals, these pathways provide a structured framework to confront fundamental limitations, promote rigorous validation, and accelerate the translation of tractography into a robust tool for neuroscience and medicine. Ultimately, the Millennium Pathways aim to guide and inspire future research and collaboration, ensuring the continued scientific and clinical relevance of tractography well into the future.2025-09-30T13:46:21ZMillennium Pathways (30 Sept, 2025)Maxime DescoteauxKurt G. SchillingDogu Baran AydoganChristian BeaulieuElena BorraMaxime ChamberlandAlessandro DaducciAlberto De LucaFlavio Dell'AcquaJessica DuboisTim B. DyrbyShawna FarquharsonStephanie ForkelMartijn FroelingAlessandra GriffaMareike GrotheerPamela GuevaraSuzanne N. HaberVinod Kumar JangirAlexander LeemansJoel LefebvreChing-Po LinGraham LittleChun-Yi Zac LoChiara MaffeiHelen S. MaybergJennifer A. McNabPratik MukherjeeLauren J. O'DonnellMartin ParentCarlo PierpaoliFrancois RheaultKathleen S. RocklandAlard RoebroeckAriel RokemR. Jarrett RushmoreSilvio SarubboSimona SchiaviStamatios N SotiropoulosDiego SzczupakMichel Thiebaut de SchottenJ-Donald TournierFrancesco VerganiJoseph Yuan-Mou YangFan ZhangDerek JonesLaurent Petithttp://arxiv.org/abs/2506.07230v2First positronium imaging using $^{44}$Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom2025-09-29T17:04:44ZPositronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the $^{68}$Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, $^{44}$Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with $^{44}$Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph-the first plastic scintillators-based PET scanner.2025-06-08T17:27:32ZIEEE Trans. Radiat. Plasma Med. Sci. 10(4) (2026) 593Manish DasSushil SharmaAleksander BilewiczJarosław ChoińskiNeha ChugCatalina CurceanuEryk CzerwińskiJakub HajdugaSharareh JalaliKrzysztof KacprzakTevfik KaplanogluŁukasz KapłonKamila KasperskaAleksander KhreptakGrzegorz KorcylTomasz KozikKarol KubatDeepak KumarAnoop Kunimmal VenadanEdward LisowskiFilip LisowskiJustyna Medrala-SowaSimbarashe MoyoWiktor MrykaSzymon NiedźwieckiPiyush PandeySzymon ParzychAlessio PorcelliBartłomiej RachwałElena Perez del RioMartin RädlerAxel RomingerKuangyu ShiMagdalena SkurzokAnna StolarzTomasz SzumlakPooja TantyKeyvan Tayefi ArdebiliSatyam TiwariKavya Valsan EliyanRafał WalczakErmias Yitayew BeyeneEwa Ł. StępieńPaweł Moskal10.1109/TRPMS.2025.3621554