https://arxiv.org/api/rik46ecp6o3o3ICTuoyV1QT7k3I 2026-06-25T20:01:05Z 9007 855 15 http://arxiv.org/abs/2501.07348v3 Ultrasonic Medical Tissue Imaging Using Probabilistic Inversion: Leveraging Variational Inference for Speed Reconstruction and Uncertainty Quantification 2025-10-14T08:01:53Z Full Waveform Inversion (FWI) is a promising technique for achieving high-resolution imaging in medical ultrasound. However, conventional FWI methods suffer from issues related to computational efficiency, dependence on initial models, and the inability to quantify uncertainty. This study aims to enhance inversion performance and provide a reliable method for uncertainty quantification in medical FWI imaging. This study integrates the Stein Variational Gradient Descent (SVGD) algorithm into the FWI framework by deriving the posterior gradient for probabilistic inversion. To evaluate the proposed method, numerical experiments are conducted on synthetic datasets, including a breast tissue model with realistic anatomical structure. Imaging accuracy and uncertainty quantification are assessed to compare the performance of SVGD-based FWI with conventional FWI and Stochastic Variational Inference (SVI) methods. Markov Chain Monte Carlo (MCMC) is implemented as a benchmark to evaluate the quality of uncertainty estimates. For synthetic data, the SVGD-based FWI framework yields more precise estimates in the region of interest (ROI) and demonstrates faster convergence compared to the conventional FWI. For the anatomically realistic breast tissue simulation, SVGD produces a maximum relative error of 1.10\% and a mean relative error of 0.09\% in the ROI. The estimated uncertainty is spatially consistent, with most values below 0.01 and a mean of approximately 0.003. Compared to SVI, SVGD provides improved structural resolution and stronger agreement with the MCMC benchmark, indicating more reliable uncertainty quantification. The SVGD-based FWI method improves inversion quality, enhances uncertainty quantification. These findings indicate that probabilistic inversion is a promising tool for addressing the limitations of traditional FWI methods in ultrasonic imaging of medical tissues. 2025-01-13T14:14:05Z 29 pages, 13 figures Qiang Li Heyu Ma Chengcheng Liu Dean Ta http://arxiv.org/abs/2501.12797v2 A double multi-turn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities 2025-10-13T18:02:54Z The low relative charge-to-mass ratio offset of 0.065% between fully ionized helium-4 and carbon-12 ions enables simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately three times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One possibility for creating this mixed beam is accelerating the two ion species sequentially through the LINAC and subsequently "mixing" them at injection energy in the synchrotron with a double multi-turn injection scheme. This work reports the first successful generation, acceleration, and extraction of a mixed helium and carbon ion beam using this double multi-turn injection scheme, which was achieved at the MedAustron therapy accelerator in Austria. A description of the double multi-turn injection scheme, particle tracking simulations, and details on the implementation at the MedAustron accelerator facility are presented and discussed. Finally, measurements of the mixed beam at delivery in the irradiation room using a radiochromic film and a low-gain avalanche diode (LGAD) detector are presented. 2025-01-22T11:01:15Z 16 pages, 14 figures Phys. Rev. Accel. Beams 28, 111001 (2025) Matthias Kausel Claus Schmitzer Andreas Gsponer Markus Wolf Hermann Fuchs Felix Ulrich-Pur Thomas Bergauer Albert Hirtl Nadia Gambino Elisabeth Renner 10.1103/t3b5-1xb6 http://arxiv.org/abs/2504.10423v3 Overcoming light scattering with high optical nonlinearity 2025-10-13T12:58:44Z While scattered light conveys most of the information we perceive, scattering may also distort that information before it reaches our detectors. The problem is acute in many applications, such as in high-resolution microscopy of biological tissue, where scattering degrades both resolution and signal-to-noise ratio. Here, for the first time, we demonstrate that uniting two intrinsic properties of scattered light: speckle statistics and the angular memory effect, with highly non-linear optical response yields, rather surprisingly, super-resolution, low-background, non-invasive imaging of objects completely hidden behind a strongly scattering, opaque layer. Crucially, our technique of non-invasive imaging through scatterers does not resort to wavefront shaping, adaptive optics, complicated optical setups, or iterative image reconstruction algorithms. Because the strategy relies solely on the properties of scattered light and high-order nonlinear response of the fluorophores, it can be applied to any speckle-forming propagation, from biological tissue to multicore fibres, combined with any type of phenomenon that exhibits a sufficiently high order nonlinearity. 2025-04-14T17:10:24Z All the comments welcome - check the newest version (v3) Pawel Szczypkowski Adrian Makowski Wojciech Zwoliński Katarzyna Prorok Piotr Wasylczyk Artur Bednarkiewicz Radek Lapkiewicz http://arxiv.org/abs/2503.09900v2 In-vitro measurements coupled with in-silico simulations for stochastic calibration and uncertainty quantification of the mechanical response of biological materials 2025-10-13T12:20:27Z This study proposes a simple and practical approach based on in-vitro measurements and in-silico simulation using the likelihood-free Bayesian inference with the finite element method simultaneously for stochastic calibration and uncertainty quantification of the mechanical response of biological materials. We implement the approach for distal, middle, and proximal human Achilles tendon specimens obtained from diabetic patients post-amputation. A wide range of in-vitro loading conditions are considered, including one-step and two-step relaxation, as well as incremental cyclic loading tests. In-silico simulations are performed for the tendons assuming a fiber-reinforced viscoelastic response, which is modeled for the ground matrix and fiber components. Initially, the calibration of the specimen-specific parameters is predicted using Bayesian optimization and the sensitivity of each parameter is evaluated using the Sobol index and random forest. Then, these parameters are used as priors, and coupled with in-vitro data in simulation-based approximate Bayesian computation to calibrate and quantify the uncertainty parameters for three loading cases. The results demonstrate that in-silico simulations using the posterior parameters of approximate Bayesian computation can capture the uncertainty bounds of in-vitro measurements. This approach provides a useful framework for stochastic calibration of constitutive material model parameters without the need to derive a likelihood function, regardless of the specimen's geometry or loading conditions. 2025-03-12T23:36:53Z Mahmut Pekedis http://arxiv.org/abs/2505.09023v2 Probing arbitrary polarized photon pairs undergoing double Compton scatterings by a dedicated MC simulator validated with experimental data 2025-10-13T05:58:28Z Quantum correlations in the polarization degrees of freedom of the two-photon system have been extensively studied and form our current understanding of the quantum nature of our world. Most of the studies are concentrated on the low-energy (optical) photon pairs, for which efficient polarization measurement devices exist. However, for high-energetic (MeV) pairs of photons, e.g. produced in the decay of positronium atoms, no polarizers are available. Partial information about the polarization degree of freedom can be extracted by exploiting the measurements of photon pairs that undergo double Compton scattering. We present a Geant4-based Monte Carlo Vienna-Warsaw model capable of simulating any initial polarization state of bipartite photons. This puts us in a position to derive the behavior of the experimental observable, the angular difference $Δ\hatΦ$ formed by the two scattering planes. We validate our Vienna-Warsaw simulator with the high-statistics experimental sample -- based on a total of $3 \times 10^5 $ event candidates -- of two-photon pairs measured with the J-PET Big Barrel detector. We deduce the value of the squared visibility (interference contrast) encoding the polarization in the angle difference of the two scattering planes, $Δ\hatΦ$. The simulated spectra are in good agreement with the experimental correlation spectra and behave as predicted by theory. 2025-05-13T23:37:02Z Published in EPJC. 23 pages, 16 figures. Experimental dataset is overlapping with the one used in arXiv:2407.08574v3 [nucl-ex] . The first version of the current article was finalized on 16.08.2023. The submission was postponed at the request of the JPET group leader P.Moskal, who wanted to prioritize arXiv:2407.08574v3 [nucl-ex] Eur. Phys. J. C (2025) 85: 1115 M. Bala W. Krzemien B. C. Hiesmayr J. Baran K. Dulski K. Klimaszewski L. Raczynski R. Y. Shopa W. Wislicki 10.1140/epjc/s10052-025-14862-y http://arxiv.org/abs/2510.11754v1 Zero-Shot Large Language Model Agents for Fully Automated Radiotherapy Treatment Planning 2025-10-12T19:21:21Z Radiation therapy treatment planning is an iterative, expertise-dependent process, and the growing burden of cancer cases has made reliance on manual planning increasingly unsustainable, underscoring the need for automation. In this study, we propose a workflow that leverages a large language model (LLM)-based agent to navigate inverse treatment planning for intensity-modulated radiation therapy (IMRT). The LLM agent was implemented to directly interact with a clinical treatment planning system (TPS) to iteratively extract intermediate plan states and propose new constraint values to guide inverse optimization. The agent's decision-making process is informed by current observations and previous optimization attempts and evaluations, allowing for dynamic strategy refinement. The planning process was performed in a zero-shot inference setting, where the LLM operated without prior exposure to manually generated treatment plans and was utilized without any fine-tuning or task-specific training. The LLM-generated plans were evaluated on twenty head-and-neck cancer cases against clinical manual plans, with key dosimetric endpoints analyzed and reported. The LLM-generated plans achieved comparable organ-at-risk (OAR) sparing relative to clinical plans while demonstrating improved hot spot control (Dmax: 106.5% vs. 108.8%) and superior conformity (conformity index: 1.18 vs. 1.39 for boost PTV; 1.82 vs. 1.88 for primary PTV). This study demonstrates the feasibility of a zero-shot, LLM-driven workflow for automated IMRT treatment planning in a commercial TPS. The proposed approach provides a generalizable and clinically applicable solution that could reduce planning variability and support broader adoption of AI-based planning strategies. 2025-10-12T19:21:21Z Accepted for poster presentation at the NeurIPS 2025 Workshop on GenAI for Health: Potential, Trust, and Policy Compliance Dongrong Yang Xin Wu Yibo Xie Xinyi Li Qiuwen Wu Jackie Wu Yang Sheng http://arxiv.org/abs/2510.10717v1 Formulation and Therapeutic Assessment of a Zinc Oxide, Silver, and Cerium Oxide Enriched Ointment for Accelerated Wound Healing in Aged Models 2025-10-12T17:41:50Z Chronic wounds present a major challenge in elderly individuals due to diminished regenerative capacity and impaired tissue repair mechanisms associated with aging. In this study, we formulated a topical gel composed of zinc oxide (ZnO), silver (Ag), and cerium oxide (CeO2) nanoparticles, each chosen for their respective antimicrobial, antioxidant, and tissue-regenerative properties. The nanoparticles were synthesized through precise precipitation or reduction techniques and thoroughly characterized using UV-Vis spectroscopy, dynamic light scattering (DLS), Fourier-transform infrared spectroscopy (FTIR), and electron microscopy to confirm nanoscale structure and purity. An in vivo wound healing model utilizing aged Sprague-Dawley rats was employed, with animals divided into three groups: untreated, placebo-treated, and those receiving the nanoparticle-enriched gel. Wound dimensions were tracked for 14 days, revealing significantly improved healing in the nanoparticle-treated group, with nearly complete closure observed by day 14 (ANOVA, p less than 0.0001). Cytocompatibility was assessed via MTT assay on L929 fibroblasts, confirming greater than 80 percent viability at therapeutically relevant concentrations. These findings underscore the potential of multifunctional nanoparticle-based formulations to enhance wound healing in aged or compromised skin environments, offering a promising therapeutic avenue. 2025-10-12T17:41:50Z 13 Iqra Yousaf Aneela Anwar Atika Umer http://arxiv.org/abs/2510.10612v1 UltraScatter: Ray-Based Simulation of Ultrasound Scattering 2025-10-12T13:48:46Z Traditional ultrasound simulation methods solve wave equations numerically, achieving high accuracy but at substantial computational cost. Faster alternatives based on convolution with precomputed impulse responses remain relatively slow, often requiring several minutes to generate a full B-mode image. We introduce UltraScatter, a probabilistic ray tracing framework that models ultrasound scattering efficiently and realistically. Tissue is represented as a volumetric field of scattering probability and scattering amplitude, and ray interactions are simulated via free-flight delta tracking. Scattered rays are traced to the transducer, with phase information incorporated through a linear time-of-flight model. Integrated with plane-wave imaging and beamforming, our parallelized ray tracing architecture produces B-mode images within seconds. Validation with phantom data shows realistic speckle and inclusion patterns, positioning UltraScatter as a scalable alternative to wave-based methods. 2025-10-12T13:48:46Z Accepted at IEEE IUS 2025 Felix Duelmer Mohammad Farid Azampour Nassir Navab http://arxiv.org/abs/2510.09982v1 Tumor Obliteration by Resonant Amplification (TOR) A Nonthermal, Spectrally-Targeted Approach to Cancer Disintegration 2025-10-11T03:19:14Z Tumor Obliteration by Resonant Amplification (TOR) was evaluated purely in simulation. Forward models in COMSOL, ANSYS, and ABAQUS used the same small-strain rheology, nonthermal/noncavitational limits, and an emulated closed loop (phase-locked actuation plus contrast/safety gating). Over >= 200 Monte Carlo runs per setup, TOR produced per-focus extinction in 2.6-3.2 s at approx. 0.85-0.90 J/cm^3, with selectivity Q = 39 +/- 5, peak temperature rise dT_max <= 0.2 deg C, and CEM43 << 1, consistent with strictly nonthermal operation. Primary indices indicated high spectral fidelity and intrinsic safety margin: MMI = 0.92 +/- 0.03, SSR = 14.6 +/- 3.1 (circumscribed) / 11.2 +/- 2.4 (infiltrative), and ATI <= 0.8 of the matrix-failure threshold. Simulated foci matched FE predictions within +/- 150 um. A unitless reality-adherence score comparing four observables to consolidated literature ranges yielded A = 95% +/- 2% (BCa 95%). Organ-specific estimates were 95.1% (pancreatic ductal adenocarcinoma), 96.0% (prostatic acinar adenocarcinoma), and 94.2% (invasive ductal carcinoma of the breast). The delivery stack - tungsten micro-needle (300-500 um) with 5-25 um tip excursions, phase lock, and amplitude gating - operated in a small-strain, noncavitational regime, keeping off-target strain below safety limits by design. Mechanistically, mode-selective collapse implies suppression of core vesicle biogenesis and nociceptor drive; rim scanning is constrained by healthy-referenced bounds, motivating compact neuroimmune readouts in future tests. Overall, the calibrated multiphysics results support a reproducible, spectrum-locked path from modeling to benchtop: deterministic extinction at low energy, high selectivity, and strict thermal neutrality, with pre-registered experiments planned to confirm the predicted safety and efficacy envelopes. 2025-10-11T03:19:14Z 26 pages, 11 figures, 6 tables; simulation-only study; compiled with pdflatex Cesar Mello Fernando Medina da Cunha http://arxiv.org/abs/2506.22650v2 What if each voxel were measured with a different diffusion protocol? 2025-10-10T19:38:53Z Expansion of diffusion MRI (dMRI) both into the realm of strong gradients, and into accessible imaging with portable low-field devices, brings about the challenge of gradient nonlinearities. Spatial variations of the diffusion gradients make diffusion weightings and directions non-uniform across the field of view, and deform perfect shells in the q-space designed for isotropic directional coverage. Such imperfections hinder parameter estimation: Anisotropic shells hamper the deconvolution of fiber orientation distribution function (fODF), while brute-force retraining of a nonlinear regressor for each unique set of directions and diffusion weightings is computationally inefficient. Here we propose a protocol-independent parameter estimation (PIPE) method that enables fast parameter estimation for the most general case where the scan in each voxel is acquired with a different protocol in q-space. PIPE applies for any spherical convolution-based dMRI model, irrespective of its complexity, which makes it suitable both for white and gray matter in the brain or spinal cord, and for other tissues where fiber bundles have the same properties within a voxel (fiber response), but are distributed with an arbitrary fODF. Applied to in vivo human MRI with linear tensor encoding on a high-performance system, PIPE maps fiber response and fODF parameters for the whole brain in the presence of significant gradient nonlinearities in under 3 minutes. PIPE enables fast parameter estimation in the presence of arbitrary gradient nonlinearities, eliminating the need to arrange dMRI in shells or to retrain the estimator for different protocols in each voxel. PIPE applies for any model based on a convolution of a voxel-wise fiber response and fODF, and data from varying b-values, diffusion/echo times, and other scan parameters. 2025-06-27T21:40:14Z Santiago Coelho Gregory Lemberskiy Ante Zhu Hong-Hsi Lee Nastaren Abad Thomas K. F. Foo Els Fieremans Dmitry S. Novikov http://arxiv.org/abs/2510.09758v1 Stochastic numerical head phantoms to enable virtual imaging studies of transcranial photoacoustic computed tomography 2025-10-10T18:05:15Z Transcranial photoacoustic computed tomography (PACT) is an emerging neuroimaging modality, but skull-induced aberrations can result in severe image artifacts if not compensated for during image reconstruction. The development of advanced image reconstruction methods for transcranial PACT is hindered by the lack of well-characterized, clinically relevant evaluation frameworks. Virtual imaging studies offer a solution, but require realistic numerical phantoms. To address this need, this study introduces a framework for generating ensembles of realistic 3D numerical head phantoms for virtual imaging studies. The framework uses adjunct CT data to create anatomical phantoms, which are then enhanced with stochastically synthesized vasculature and assigned realistic optical and acoustic-elastic properties. The utility of the framework is demonstrated through a case study on the impact of skull modeling errors on transcranial PACT image quality. By allowing researchers to assess and refine reconstruction methods meaningfully, the presented framework is expected to accelerate the development of transcranial PACT. 2025-10-10T18:05:15Z Preprint submitted to Elsevier Photoacoustics Hsuan-Kai Huang Joseph Kuo Seonyeong Park Umberto Villa Lihong V. Wang Mark A. Anastasio http://arxiv.org/abs/2510.09570v1 Differential Analysis of Pseudo Haptic Feedback: Novel Comparative Study of Visual and Auditory Cue Integration for Psychophysical Evaluation 2025-10-10T17:22:41Z Pseudo-haptics exploit carefully crafted visual or auditory cues to trick the brain into "feeling" forces that are never physically applied, offering a low-cost alternative to traditional haptic hardware. Here, we present a comparative psychophysical study that quantifies how visual and auditory stimuli combine to evoke pseudo-haptic pressure sensations on a commodity tablet. Using a Unity-based Rollball game, participants (n = 4) guided a virtual ball across three textured terrains while their finger forces were captured in real time with a Robotous RFT40 force-torque sensor. Each terrain was paired with a distinct rolling-sound profile spanning 440 Hz - 4.7 kHz, 440 Hz - 13.1 kHz, or 440 Hz - 8.9 kHz; crevice collisions triggered additional "knocking" bursts to heighten realism. Average tactile forces increased systematically with cue intensity: 0.40 N, 0.79 N and 0.88 N for visual-only trials and 0.41 N, 0.81 N and 0.90 N for audio-only trials on Terrains 1-3, respectively. Higher audio frequencies and denser visual textures both elicited stronger muscle activation, and their combination further reduced the force needed to perceive surface changes, confirming multisensory integration. These results demonstrate that consumer-grade isometric devices can reliably induce and measure graded pseudo-haptic feedback without specialized actuators, opening a path toward affordable rehabilitation tools, training simulators and assistive interfaces. 2025-10-10T17:22:41Z 17 Pages, 9 Figures Nishant Gautam Somya Sharma Peter Corcoran Kaspar Althoefer http://arxiv.org/abs/2510.09098v1 MORSE: Multiple Orthogonal Reference Sensitivity Encoding 2025-10-10T07:52:26Z Parallel imaging is ubiquitous in MRI, enabling diverse applications such as ultra-high-resolution functional and quantitative imaging with greater temporal resolution or reduced scan times respectively. Successful unfolding is contingent on robust and accurate estimation of the relative coil sensitivities, which often involves computation times that preclude real-time deployment. Here we present a computationally-efficient method of robustly estimating coil sensitivities, and reconstructing under-sampled images using a data-driven regularised SENSE formalism. Our MORSE scheme estimates multiple sensitivities per voxel to address issues such as rapidly varying sensitivities, chemical shift artefact, or insufficient fields of view and provides a data-driven regularisation term for noise control. Exemplar structural and functional image reconstructions at 3T and 7T are presented and compared with a vendor-provided GRAPPA reconstruction as well as state-of-the-art ESPIRiT and LORAKS algorithms. MORSE consistently produced high-quality, artefact-free images with reconstruction times feasible for real-time deployment. It is flexible and robust, and made available to the community in open-source as a library of functions within the vendor-agnostic Gadgetron image reconstruction framework. 2025-10-10T07:52:26Z 10 pages, 6 figures, This work has been submitted to the IEEE for possible publication Oliver Josephs Barbara Dymerska Nadine N. Graedel Yael Balbastre Nadege Corbin Martina F. Callaghan http://arxiv.org/abs/2510.09713v1 Statistical Shape Modelling of the Nasosinusal Anatomy 2025-10-10T05:56:41Z The human nose exhibits a huge variation in shape among individuals. All these variants alter the airflow through the nasal cavity and can impact how we smell odors. To acquire a better understanding of physiological and pathological functioning, it is important to study the effects of these modifications. SSM, or Statistical Shape Modelling, is a widely used methodology for considering morphological differences within a population. In the literature, only a few studies analyze nasal anatomy in its entirety, including paranasal sinuses, whose segmentation is particularly challenging due to their complexity and variability. This work aims at creating a highly accurate SSM for the nasosinusal complex. A traditional, greyscale thresholding-based segmentation approach was chosen, relying on Mimics software (Leuven, Belgium). 40 computed tomography (CT) datasets were considered. After segmentation, post-processing was performed to obtain watertight meshes using 3-Matic software (Leuven, Belgium), which was also used for the SSM generation. The generated model shows all relevant landmarks that typically characterize a nasosinual complex. 32 different modes are needed to explain 95% of the total variance. As a preliminary output, this study showed the feasibility and consistency of a statistical model of the nasosinusal anatomy. However, additional studies involving a larger sample size and a more robust validation process could be conducted. 2025-10-10T05:56:41Z ASME 2024 International Mechanical Engineering Congress and Exposition, Nov 2024, Portland, France Michele Bertolini POLIMI Silvia Tonghini POLIMI Marco Rossoni POLIMI Marina Carulli POLIMI Susanne Weise TU Dresden Christian Jan Baldus POLIMI Giorgio Colombo POLIMI Monica Bordegoni POLIMI http://arxiv.org/abs/2510.08943v1 A pilot cohort study of a microfluidic-based point-of-care bilirubin measurement system 2025-10-10T02:49:50Z Objective The concentration of bilirubin in blood or serum is useful for assessing liver function as well as monitoring treatment. This study evaluates the clinical performance of a novel point-of-care (PoC) device for the detection of bilirubin in serum. The PoC device incorporates an integrated miniature optoelectronic sensing module and a microfluidic test cartridge. Methods Patients' serum total bilirubin concentrations, ranging from 2 μmol/L to 480 μmol/L, were measured using the PoC device and the standard laboratory method (n=20). Bland-Altman analysis and regression analysis using Passing-Bablok method were used to benchmark the PoC device against the standard laboratory measurements. The diagnostic capability of the PoC device in categorising the serum samples within clinically relevant bilirubin concentration thresholds of 200, 300, and 450 μmol/L was assessed using receiver operating characteristic (ROC) analysis. Results The mean difference between the PoC device and the standard laboratory method was -5.6 μmol/L, with a 95% confidence interval (CI) of -45.1 μmol/L to 33.9 μmol/L. The coefficient of determination (R2) was 0.986. The PoC device achieved a detection sensitivity of 90% and specificity of 97% in categorising bilirubin concentrations within bands used in clinical decision-making. Conclusions This study demonstrates that the proposed PoC device is capable of measuring bilirubin levels in patient samples with clinically acceptable accuracy. 2025-10-10T02:49:50Z LabMed Discovery 2.2 (2025): 100073 Jean Pierre Ndabakuranye Inge W. G. Last Kay Weng Choy Peter Thurgood Jason C. Steel Genia Burchall Stella Stylianou Khashayar Khoshmanesh Arman Ahnood 10.1016/j.lmd.2025.100073