https://arxiv.org/api//QSe8nFPeIC9tcvFIk23B3aBWHc 2026-06-25T19:01:39Z 9007 840 15 http://arxiv.org/abs/2510.14873v1 Sampling Density Compensation using Fast Fourier Deconvolution 2025-10-16T16:51:39Z Density Compensation Function (DCF) is widely used in non-Cartesian MRI reconstruction, either for direct Non-Uniform Fast Fourier Transform (NUFFT) reconstruction or for iterative undersampled reconstruction. Current state-of-the-art methods involve time-consuming tens of iterations, which is one of the main hurdles for widespread application of the highly efficient non-Cartesian MRI. In this paper, we propose an efficient, non-iterative method to calculate DCF for arbitrary non-Cartesian $k$-space trajectories using Fast Fourier Deconvolution. Simulation experiments demonstrate that the proposed method is able to yield DCF for 3D non-Cartesian reconstruction in around 20 seconds, achieving orders of magnitude speed improvement compared to the state-of-the-art method while achieving similar reconstruction quality. 2025-10-16T16:51:39Z Rui Luo Peng Hu Haikun Qi http://arxiv.org/abs/2403.12331v2 Deep Few-view High-resolution Photon-counting CT at Halved Dose for Extremity Imaging 2025-10-16T16:10:31Z X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging but its radiation dose can be further improved. Despite the great potential of deep learning techniques, their application in HR volumetric PCCT reconstruction has been challenged by the large memory burden, training data scarcity, and domain gap issues. In this paper, we propose a deep learning-based approach for PCCT image reconstruction at halved dose and doubled speed validated in a New Zealand clinical trial. Specifically, we design a patch-based volumetric refinement network to alleviate the GPU memory limitation, train network with synthetic data, and use model-based iterative refinement to bridge the gap between synthetic and clinical data. Our results in a reader study of 8 patients from the clinical trial demonstrate a great potential to cut the radiation dose to half that of the clinical PCCT standard without compromising image quality and diagnostic value. 2024-03-19T00:07:48Z Accepted for publication in IEEE TMI, https://ieeexplore.ieee.org/document/11200164; IEEE Transactions on Medical Imaging Mengzhou Li Chuang Niu Ge Wang Maya R Amma Krishna M Chapagain Stefan Gabrielson Andrew Li Kevin Jonker Niels de Ruiter Jennifer A Clark Phil Butler Anthony Butler Hengyong Yu 10.1109/TMI.2025.3618754 http://arxiv.org/abs/2507.13854v2 Advanced X-rays techniques for research-oriented high-resolution imaging of articular cartilage: a scoping review 2025-10-16T09:56:33Z Articular cartilage is a musculoskeletal soft tissue renowned for its unique mechanical properties. Understanding both its hierarchical structure and the interplay between its constituents could shed light on the mechanical competence of the tissue. Therefore, rheologic approaches based on high-resolution non-destructive imaging techniques are desired. In this context, X-ray imaging could ideally accomplish this task. Nevertheless, the nature of articular cartilage translates into poor contrast using conventional absorption modality. To overcome this limitation, several approaches can be embraced. X-ray visibility of articular cartilage can be increased with the use of radiopaque contrast agents. Therefore, further discrimination of structures could be provided by spectral techniques, pivoting on either multi-energy acquisitions or photon-counting technology. Alternatively, phase-contrast techniques unveil details typically undetected with conventional approaches. Phase-contrast imaging, based on the intrinsic decrement in the refractive index of the tissue, can be achieved with different configurations and implementations, including distinct X-ray sources and optical elements. Additionally, some phase-contrast techniques retrieve the small-angle scattering-based dark-field signal, relatable to sub-pixel structures. This scoping review aims to catalogue the application of these advanced X-ray techniques to articular cartilage imaging, following PRISMA guidelines. It discusses their advantages, limitations, and includes an overview of rheologic applications to articular cartilage. 2025-07-18T12:20:12Z 66 pages, 8 figures, 9 tables Simone Fantoni Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy Luca Brombal Department of Physics, University of Trieste, Trieste, Italy INFN, Division of Trieste, Trieste, Italy Paolo Cardarelli INFN, Division of Ferrara, Ferrara, Italy Fabio Baruffaldi Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy http://arxiv.org/abs/2510.14353v1 CURE: Confidence-driven Unified Reasoning Ensemble Framework for Medical Question Answering 2025-10-16T06:46:11Z High-performing medical Large Language Models (LLMs) typically require extensive fine-tuning with substantial computational resources, limiting accessibility for resource-constrained healthcare institutions. This study introduces a confidence-driven multi-model framework that leverages model diversity to enhance medical question answering without fine-tuning. Our framework employs a two-stage architecture: a confidence detection module assesses the primary model's certainty, and an adaptive routing mechanism directs low-confidence queries to Helper models with complementary knowledge for collaborative reasoning. We evaluate our approach using Qwen3-30B-A3B-Instruct, Phi-4 14B, and Gemma 2 12B across three medical benchmarks; MedQA, MedMCQA, and PubMedQA. Result demonstrate that our framework achieves competitive performance, with particularly strong results in PubMedQA (95.0\%) and MedMCQA (78.0\%). Ablation studies confirm that confidence-aware routing combined with multi-model collaboration substantially outperforms single-model approaches and uniform reasoning strategies. This work establishes that strategic model collaboration offers a practical, computationally efficient pathway to improve medical AI systems, with significant implications for democratizing access to advanced medical AI in resource-limited settings. 2025-10-16T06:46:11Z Ziad Elshaer Essam A. Rashed http://arxiv.org/abs/2510.11504v3 Towards polarization-enhanced PET: Study of random background in polarization-correlated Compton events 2025-10-15T20:10:46Z Positron Emission Tomography (PET) is a medical imaging modality that utilizes positron-emitting isotopes, such as Ga-68 and F-18, for many diagnostic purposes. The positron annihilates with an electron from the surrounding area, creating two photons of 511 keV energy and opposite momenta, entangled in their orthogonal polarizations. When each photon undergoes a Compton scattering process, the difference of their azimuthal scattering angles reflects the initial orthogonality of their polarizations, peaking at $\pm$90$^{\circ}$. This type of correlation is not yet utilized in conventional PET scanners, but could potentially offer an energy-independent method for background reduction. Measurements of these kinds of correlations can be achieved using Compton polarimeters, built from a single layer of segmented scintillating crystals such as Gadolinium Aluminium Gallium Garnet doped with Cerium (GAGG:Ce), read out by silicon photomultipliers (SiPMs). In this paper, we study the signal-to-random background ratios in measurements of these correlated annihilation photons from coincidence time spectra across clinically relevant source activities, from $\sim$200 MBq to $\sim$378 MBq. These are then compared to the standard single-pixel (photoelectric) measurements. We find that the signal-to-random background ratios (SBRs) obtained from the polarization-correlated events for Compton scattering angles $θ_{1,2}\in[72^{\circ}, 90^{\circ}]$ and azimuthal angle difference $Δφ=90^{\circ}\pm20^{\circ}$ are consistently higher than those from single-pixel events, with the ratio of their SBR values of 1.23. The SBR of the selected events also increases with the polarimetric modulation factor $μ$, gaining $\sim$50\% in value during the experiment. 2025-10-13T15:14:06Z 14 pages, 8 figures Ana Marija Kožuljević Tomislav Bokulić Darko Grošev Siddharth Parashari Luka Pavelić Marinko Rade Marijan Žuvić Mihael Makek http://arxiv.org/abs/2510.13562v1 An efficient approach with theoretical guarantees to simultaneously reconstruct activity and attenuation sinogram for TOF-PET 2025-10-15T14:01:03Z In positron emission tomography (PET), it is indispensable to perform attenuation correction in order to obtain the quantitatively accurate activity map (tracer distribution) in the body. Generally, this is carried out based on the estimated attenuation map obtained from computed tomography or magnetic resonance imaging. However, except for errors in the attenuation correction factors obtained, the additional scan not only brings in new radiation doses and/or increases the scanning time but also leads to severe misalignment induced by various motions during and between the two sequential scans. To address these issues, based on maximum likelihood estimation, we propose a new mathematical model for simultaneously reconstructing the activity and attenuation sinogram from the time-of-flight (TOF)-PET emission data only. Particularly, we make full use of the exclusively exponential form for the attenuation correction factors, and consider the constraint of a total amount of the activity in some mask region in the proposed model. Furthermore, we prove its well-posedness, including the existence, uniqueness and stability of the solution. We propose an alternating update algorithm to solve the model, and also analyze its convergence. Finally, numerical experiments with various TOF-PET emission data demonstrate that the proposed method is of numerical convergence and robust to noise, and outperforms some state-of-the-art methods in terms of accuracy and efficiency, and has the capability of autonomous attenuation correction. 2025-10-15T14:01:03Z 32 pages, 11 figures, 4 tables IEEE Transactions on Computational Imaging 2026 Liyang Hu Chong Chen 10.1109/TCI.2026.3697651 http://arxiv.org/abs/2510.13480v1 A Quantitative Holographic Agglutination Assay for Immunoglobulin A 2025-10-15T12:27:10Z This study introduces a Holographic Agglutination Assay for quantifying levels of the immunoglobulin protein IgA in biological samples. This is the first example of a label-free and bead-free assay that quantifies protein agglutinates by direct detection using Total Holographic Characterization. A proof-of-concept assay for human serum immunoglobulins is demonstrated using Jacalin, the galactose-specific plant lectin, to induce selective agglutination. By analyzing the size, refractive index, and number of particles in an assay sample, we obtain a reproducible and quantitative measurement of galactosylated immunoglobulins in a given sample. The assay is calibrated for a physiologically relevant reference interval of IgA concentrations in a 10x diluted emulated biological sample from low (80 mg/dL, 5 μM) to high (320 mg/dL, 20 μM) levels. The assay clearly distinguishes samples containing IgA from samples containing IgG. More broadly, this study introduces a platform for creating lectin-mediated Holographic Agglutination Assays to monitor levels of immunoglobulins in biological samples. The ability to quantify immunoglobulin levels efficiently in clinical samples is likely to be valuable for diagnostics and will provide a basis for assaying other proteins that can be induced to agglutinate. 2025-10-15T12:27:10Z 13 pages, 4 figures Rushna Quddus Kent Kirshenbaum David G. Grier http://arxiv.org/abs/2510.13441v1 Steerable Conditional Diffusion for Domain Adaptation in PET Image Reconstruction 2025-10-15T11:40:03Z Diffusion models have recently enabled state-of-the-art reconstruction of positron emission tomography (PET) images while requiring only image training data. However, domain shift remains a key concern for clinical adoption: priors trained on images from one anatomy, acquisition protocol or pathology may produce artefacts on out-of-distribution data. We propose integrating steerable conditional diffusion (SCD) with our previously-introduced likelihood-scheduled diffusion (PET-LiSch) framework to improve the alignment of the diffusion model's prior to the target subject. At reconstruction time, for each diffusion step, we use low-rank adaptation (LoRA) to align the diffusion model prior with the target domain on the fly. Experiments on realistic synthetic 2D brain phantoms demonstrate that our approach suppresses hallucinated artefacts under domain shift, i.e. when our diffusion model is trained on perturbed images and tested on normal anatomy, our approach suppresses the hallucinated structure, outperforming both OSEM and diffusion model baselines qualitatively and quantitatively. These results provide a proof-of-concept that steerable priors can mitigate domain shift in diffusion-based PET reconstruction and motivate future evaluation on real data. 2025-10-15T11:40:03Z Accepted for oral presentation at IEEE NSS MIC RTSD 2025 (submitted May 2025; accepted July 2025; to be presented Nov 2025) George Webber Alexander Hammers Andrew P. King Andrew J. Reader http://arxiv.org/abs/2510.13300v1 Five Years of Clinical Application of independent Monte Carlo-Based Patient-Specific Quality Assurance at the Maastro Proton Therapy Center 2025-10-15T08:40:04Z At the Maastro Proton Therapy Center in Maastricht, patient-specific quality assurance (PSQA) using an independent GPU-accelerated Monte Carlo (MC) calculation has fully replaced conventional measurements, which are time-consuming and have limited sensitivity to clinically relevant errors. A fully automated and robust pipeline was developed, integrating two clinical workflows based on the fast MC code Fred. The system is fully operational, and automatic verification reports are part of daily clinical practice. The first workflow performs a pre-treatment dose recalculation in Fred using the planning CT and clinical plan. The second uses Fred with machine log files to verify the actually delivered dose. Both generate automatic reports for clinical review. Over five years, this workflow has become part of routine clinical operations, providing robust 3D dosimetric verification in heterogeneous anatomies. So far, Fred has recalculated more than 6000 pre-treatment plans and 3513 log file-based PSQA cases, saving an estimated 4090 hours of QA work. The pipeline identified true negatives and detected two planning-related failures that would have been missed by conventional measurements. No false positives or negatives were observed, confirming high accuracy and reliability. The MC-based PSQA pipeline offers an efficient, sensitive, and clinically meaningful alternative to measurement-based QA in pencil beam scanning proton therapy. By eliminating routine measurements, it saves resources while improving patient safety and treatment quality. Five years of experience confirm that measurement-less MC-based PSQA is a viable and superior approach, providing full 3D verification and early error detection - a practical blueprint for other proton therapy centres. 2025-10-15T08:40:04Z Ilaria Rinaldi Giorgio Cartechini Angelo Schiavi Jan Gajewski Nils Krah Antoni Rucinski Gloria Vilches Freixas Vincenzo Patera Sebastiaan Nijsten http://arxiv.org/abs/2403.01178v4 RAIDER: Rapid, anatomy-independent, deep learning-based PDFF and R2* estimation using magnitude-only signals 2025-10-15T06:58:20Z There has been recent interest in the use of magnitude-based fitting methods for estimating proton density fat fraction (PDFF) and R2* from chemical shift-encoded MRI (CSE-MRI) data, since these methods can still be used when complex- based methods fail or when phase data are inaccessible or unreliable (such as in multicentre trials, low resource settings, preclinical imaging and national cohort datasets), and may also be used as a final processing step with complex-based methods. However, conventional fitting techniques are computationally expensive. Deep learning (DL)-based methods promise to accelerate parameter estimation, but there are no existing deep learning methods for voxelwise CSE-MRI tissue parameter estimation. Here, we show that a naive voxelwise multilayer perceptron (MLP) implementation suffers from poor performance because multiple tissue parameter values can produce similar signals (degeneracy), potentially accounting for this gap in the literature. To address this problem and realise the potential acceleration offered by MLP-based tissue parameter estimation, we propose RAIDER, a voxelwise method for rapid, anatomy-independent deep learning-based PDFF and R2* estimation using multi-echo magnitude-data. RAIDER utilises two neural networks, each with a separately-designed training data distribution, to deal with degeneracy and thus realise the benefits of an MLP-based approach, with a 400-fold to 2800-fold acceleration (meaning that processing takes just seconds, rather than minutes or hours). Our code is available at https://github.com/TJPBray/DixonDL. 2024-03-02T11:12:13Z Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/é Machine.Learning.for.Biomedical.Imaging. 3 (2025) T. J. P. Bray G. V. Minore A. Bainbridge L. Dwyer-Hemmings S. A. Taylor M. A. Hall-Craggs H. Zhang 10.59275/j.melba.2025-bac4 http://arxiv.org/abs/2503.08425v4 Accurate myocardial T1 mapping at 5T using an improved MOLLI method: A validation study 2025-10-15T02:29:15Z Background: Accurate myocardial T1 mapping at 5T remains a technical challenge due to field inhomogeneity and prolonged T1 values. The aim of this study is to develop an accurate and clinically applicable myocardial T1 mapping technique for 5T magnetic resonance imaging (MRI) systems and validate its performance in a multicenter study. Methods: The proposed method is based on a 5-(3)-3 MOLLI sequence, dubbed combined-correction MOLLI (coMOLLI), which corrects for both inversion efficiency and readout-induced signal disturbances. Specifically, coMOLLI employs a gradient recalled echo (GRE) readout rather than the commonly used bSSFP readout. Its signal evolution is modeled to estimate T1 values, which incorporates both inversion efficiency and readout disturbances to improve fitting accuracy. To further enhance accuracy, the inversion pulse was redesigned under hardware constraints and the observed B0 and B1 variations over the heart at 5T, using adiabatic hyperbolic secant (HSn) and tangent/hyperbolic tangent (Tan/Tanh) pulses. The method was validated in phantom experiments, as well as in 21 healthy volunteers and 9 patients. Results: The optimized inversion pulse at 5T is the Tan/Tanh pulse with A = 10 kHz, K_s = 4, k = 22, and T_p = 8 ms. In phantom studies, coMOLLI showed high accuracy versus reference IR-FSE, yielding relative errors within 5% for all nine vials. In vivo studies, the average native myocardial T1 values across 21 healthy volunteers were 1468 +/- 48 ms, 1514 +/- 39 ms, and 1545 +/- 50 ms, and blood T1 values were 2182 +/- 132 ms, 2124 +/- 153 ms, and 2131 +/- 158 ms for apical, middle, and base slices, respectively. Conclusion: The coMOLLI method demonstrated high accuracy in phantom studies and feasibility in vivo studies. By adopting the widely used 5-(3)-3 MOLLI acquisition scheme, it shows potential for clinical cardiac imaging at 5T. 2025-03-11T13:39:14Z arXiv admin note: text overlap with arXiv:2501.07081 Linqi Ge Yinuo Zhao Yubo Guo Yuanyuan Liu Yihang Zhou Haifeng Wang Dong Liang Hairong Zheng Yining Wang Yanjie Zhu http://arxiv.org/abs/2510.13062v1 Towards Human-Centric Intelligent Treatment Planning for Radiation Therapy 2025-10-15T01:04:48Z Current radiation therapy treatment planning is limited by suboptimal plan quality, inefficiency, and high costs. This perspective paper explores the complexity of treatment planning and introduces Human-Centric Intelligent Treatment Planning (HCITP), an AI-driven framework under human oversight, which integrates clinical guidelines, automates plan generation, and enables direct interactions with operators. We expect that HCITP will enhance efficiency, potentially reducing planning time to minutes, and will deliver personalized, high-quality plans. Challenges and potential solutions are discussed. 2025-10-15T01:04:48Z 27 pages, 3 figures Adnan Jafar Xun Jia http://arxiv.org/abs/2510.12714v1 Artificial intelligence for simplified patient-centered dosimetry in radiopharmaceutical therapies 2025-10-14T16:55:36Z KEY WORDS: Artificial Intelligence (AI), Theranostics, Dosimetry, Radiopharmaceutical Therapy (RPT), Patient-friendly dosimetry KEY POINTS - The rapid evolution of radiopharmaceutical therapy (RPT) highlights the growing need for personalized and patient-centered dosimetry. - Artificial Intelligence (AI) offers solutions to the key limitations in current dosimetry calculations. - The main advances on AI for simplified dosimetry toward patient-friendly RPT are reviewed. - Future directions on the role of AI in RPT dosimetry are discussed. 2025-10-14T16:55:36Z Alejandro Lopez-Montes Fereshteh Yousefirizi Yizhou Chen Yazdan Salimi Robert Seifert Ali Afshar-Oromieh Carlos Uribe Axel Rominger Habib Zaidi Arman Rahmim Kuangyu Shi http://arxiv.org/abs/2510.12609v1 Quasi-static in vivo elastography from internal displacement information only 2025-10-14T15:07:33Z As disease often alters the structural properties of soft tissue, noninvasive elastography techniques have emerged to quantitatively assess in vivo mechanical properties. Magnetic Resonance Elastography (MRE) based on dynamic deformations is the standard technique for imaging mechanical properties, but the viscoelastic nature of soft tissue makes the results dependent on the actuation frequency, which can be limiting. In this proof-of-principle study we propose a noise robust framework for reconstructing relative stiffness properties from quasi-static in vivo displacement fields captured on a physiological time scale. The acquisition is performed using a pneumatic pressure cuff to induce tissue deformation in a controlled manner. The reconstruction does not require boundary information which is generally hard to access in vivo nor spatial derivatives of displacement fields that are known to amplify noise. The validity of our framework is corroborated with in silico experiments on a numerical phantom. In vivo experiments on the thigh of a volunteer demonstrate the repeatability of the method. As an application, the quantitative change in muscle stiffness during isometric knee flexion is investigated which yielded physiologically meaningful results. 2025-10-14T15:07:33Z 15 pages, 8 figures, full paper David G. J. Heesterbeek Max H. C. van Riel Ray S. S. Sheombarsing Tristan van Leeuwen Martijn Froeling Cornelis A. T. van den Berg Alessandro Sbrizzi http://arxiv.org/abs/2510.12854v1 Scalable covalently functionalized black phosphorus hybrids for broadspectrum virucidal activity 2025-10-14T10:02:30Z At the onset of viral outbreaks, broad-spectrum antiviral materials are crucial before specific therapeutics become available. We report scalable, biodegradable black phosphorus (BP) hybrids that provide mutation-resilient virucidal protection. BP sheets, produced via an optimized mechanochemical process, are covalently functionalized with 2-azido-4,6-dichloro- 1,3,5-triazine to form P=N bonds. Fucoidan, a sulfated polysaccharide with intrinsic antiviral activity, and hydrophobic chains are then incorporated to achieve irreversible viral deactivation. The material exhibits strong antiviral inhibition and complete virucidal activity against multiple viruses, including recent severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) variants. It maintains high biocompatibility, remains effective against viral mutations, and is shelf stable for at least five month. The combination of biodegradability, scalable synthesis, and synergistic antiviral and virucidal mechanisms establishes BP-conjugates as a new class of highly efficient antivirals. They offer a broad spectrum antiviral solutions that could bridge the gap between antiviral medicines and general antiseptics. 2025-10-14T10:02:30Z Na Xing Jasmin Er Ricardo M. Vidal Sandhya Khadka Robert Schusterbauer Maik Rosentreter Ranen Etouki Rameez Ahmed Taylor Page Philip Nickl Obida Bawadkji Anja Wiesner Joerg Radnik Vasile-Dan Hodoroaba Kai Ludwig Jakob Trimpert Ievgen S. Donskyi