https://arxiv.org/api/cC9+SBEMj6uBO062Ezee32CHl30 2026-06-25T17:52:16Z 9007 825 15 http://arxiv.org/abs/2510.16973v1 Foundation Models in Medical Image Analysis: A Systematic Review and Meta-Analysis 2025-10-19T19:19:23Z Recent advancements in artificial intelligence (AI), particularly foundation models (FMs), have revolutionized medical image analysis, demonstrating strong zero- and few-shot performance across diverse medical imaging tasks, from segmentation to report generation. Unlike traditional task-specific AI models, FMs leverage large corpora of labeled and unlabeled multimodal datasets to learn generalized representations that can be adapted to various downstream clinical applications with minimal fine-tuning. However, despite the rapid proliferation of FM research in medical imaging, the field remains fragmented, lacking a unified synthesis that systematically maps the evolution of architectures, training paradigms, and clinical applications across modalities. To address this gap, this review article provides a comprehensive and structured analysis of FMs in medical image analysis. We systematically categorize studies into vision-only and vision-language FMs based on their architectural foundations, training strategies, and downstream clinical tasks. Additionally, a quantitative meta-analysis of the studies was conducted to characterize temporal trends in dataset utilization and application domains. We also critically discuss persistent challenges, including domain adaptation, efficient fine-tuning, computational constraints, and interpretability along with emerging solutions such as federated learning, knowledge distillation, and advanced prompting. Finally, we identify key future research directions aimed at enhancing the robustness, explainability, and clinical integration of FMs, thereby accelerating their translation into real-world medical practice. 2025-10-19T19:19:23Z Praveenbalaji Rajendran Mojtaba Safari Wenfeng He Mingzhe Hu Shansong Wang Jun Zhou Xiaofeng Yang http://arxiv.org/abs/2510.16920v1 Real-time MRI-based fetal femur length measurement 2025-10-19T16:34:41Z Purpose: To develop and evaluate a real-time method for automatic planning and measurement of fetal femur length - an important indicator of antenatal growth - during MRI. While routinely assessed by ultrasound, MRI-based femur length measurements remain challenging due to bone-slice misalignment, fetal motion, and the need for manual assessment. Methods: A low-latency 3D U-Net was trained on 59 scans acquired at 0.55T (gestational age 18-40 weeks) to localise the proximal and distal endpoints of the femur. These coordinates were employed to automatically adapt a 30-second EPI sequence for in-plane femur coverage in real-time. Retrospective evaluation was performed in 72 scans (19-39 weeks, including 19 pathological cases), and real-time testing in 24 cases (17-39 weeks). Automated results were compared with manual expert annotations and, in 57/72 cases, with matched clinical ultrasound measurements. Precision was evaluated against inter-observer variability and analysed across gestational age and maternal BMI. Furthermore, bilateral femur length consistency was evaluated. Results: Retrospective analysis demonstrated a mean endpoint localisation error of 5.5 mm and femur length deviation of 3.0 mm. Among the 49/72 cases with both femora automatically extracted, the left-right difference was 2.8+-2.7 mm. Precision was unaffected by maternal BMI (p>0.05), but correlated with gestational age (p<0.05). Real-time planning and assessment were successful in 22/24 cases, with a mean deviation of 4.2 mm. Conclusions: A real-time, automated method for MRI-based femur length measurement was developed, enabling precise, motion-robust, and operator-independent growth assessment, supporting future large-scale evaluation in growth-compromised pregnancies. 2025-10-19T16:34:41Z 16 pages, 6 figures Johannes Barcsay Sara Neves Silva Jordina Aviles Verdera Charline Bradshaw Mary Rutherford Susanne Schulz-Heise Jana Hutter http://arxiv.org/abs/2507.01210v2 Harnessing coherent-wave control for sensing applications 2025-10-19T13:43:51Z Imaging techniques such as functional near-infrared spectroscopy (fNIRS) and diffuse optical tomography (DOT) achieve deep, non-invasive sensing in turbid media, but they are constrained by the photon budget. Wavefront shaping (WFS) can enhance signal strength via interference at specific locations within scattering media, enhancing light-matter interactions and potentially extending the penetration depth of these techniques. Interpreting the resulting measurements rests on the knowledge of optical sensitivity - a relationship between detected signal changes and perturbations at a specific location inside the medium. However, conventional diffusion-based sensitivity models rely on assumptions that become invalid under coherent illumination. In this work, we develop a microscopic theory for optical sensitivity that captures the inherent interference effects that diffusion theory necessarily neglects. We analytically show that under random illumination, the microscopic and diffusive treatments coincide. Using our microscopic approach, we explore WFS strategies for enhancing optical sensitivity beyond the diffusive result. We demonstrate that the input state obtained through phase conjugation at a given point inside the system leads to the largest enhancement of optical sensitivity but requires an input wavefront that depends on the target position. In sharp contrast, the maximum remission eigenchannel leads to a global enhancement of the sensitivity map with a fixed input wavefront. This global enhancement equals to remission enhancement and preserves the spatial distribution of the sensitivity, making it compatible with existing DOT reconstruction algorithms. Our results establish the theoretical foundation for integrating wavefront control with diffuse optical imaging, enabling deeper tissue penetration through improved signal strength in biomedical applications. 2025-07-01T22:11:21Z 26 pages, 11 figures Phys. Rev. Appl. 24, 054027 (2025) Pablo Jara Arthur Goetschy Hui Cao Alexey Yamilov 10.1103/wwbs-pftg http://arxiv.org/abs/2510.16660v1 Universal and Transferable Attacks on Pathology Foundation Models 2025-10-18T23:03:45Z We introduce Universal and Transferable Adversarial Perturbations (UTAP) for pathology foundation models that reveal critical vulnerabilities in their capabilities. Optimized using deep learning, UTAP comprises a fixed and weak noise pattern that, when added to a pathology image, systematically disrupts the feature representation capabilities of multiple pathology foundation models. Therefore, UTAP induces performance drops in downstream tasks that utilize foundation models, including misclassification across a wide range of unseen data distributions. In addition to compromising the model performance, we demonstrate two key features of UTAP: (1) universality: its perturbation can be applied across diverse field-of-views independent of the dataset that UTAP was developed on, and (2) transferability: its perturbation can successfully degrade the performance of various external, black-box pathology foundation models - never seen before. These two features indicate that UTAP is not a dedicated attack associated with a specific foundation model or image dataset, but rather constitutes a broad threat to various emerging pathology foundation models and their applications. We systematically evaluated UTAP across various state-of-the-art pathology foundation models on multiple datasets, causing a significant drop in their performance with visually imperceptible modifications to the input images using a fixed noise pattern. The development of these potent attacks establishes a critical, high-standard benchmark for model robustness evaluation, highlighting a need for advancing defense mechanisms and potentially providing the necessary assets for adversarial training to ensure the safe and reliable deployment of AI in pathology. 2025-10-18T23:03:45Z 38 Pages, 8 Figures Light: Science & Applications (2026) Yuntian Wang Xilin Yang Che-Yung Shen Nir Pillar Aydogan Ozcan 10.1038/s41377-026-02347-w http://arxiv.org/abs/2510.16321v1 Time-Embedded Algorithm Unrolling for Computational MRI 2025-10-18T03:10:09Z Algorithm unrolling methods have proven powerful for solving the regularized least squares problem in computational magnetic resonance imaging (MRI). These approaches unfold an iterative algorithm with a fixed number of iterations, typically alternating between a neural network-based proximal operator for regularization, a data fidelity operation and auxiliary updates with learnable parameters. While the connection to optimization methods dictate that the proximal operator network should be shared across unrolls, this can introduce artifacts or blurring. Heuristically, practitioners have shown that using distinct networks may be beneficial, but this significantly increases the number of learnable parameters, making it challenging to prevent overfitting. To address these shortcomings, by taking inspirations from proximal operators with varying thresholds in approximate message passing (AMP) and the success of time-embedding in diffusion models, we propose a time-embedded algorithm unrolling scheme for inverse problems. Specifically, we introduce a novel perspective on the iteration-dependent proximal operation in vector AMP (VAMP) and the subsequent Onsager correction in the context of algorithm unrolling, framing them as a time-embedded neural network. Similarly, the scalar weights in the data fidelity operation and its associated Onsager correction are cast as time-dependent learnable parameters. Our extensive experiments on the fastMRI dataset, spanning various acceleration rates and datasets, demonstrate that our method effectively reduces aliasing artifacts and mitigates noise amplification, achieving state-of-the-art performance. Furthermore, we show that our time-embedding strategy extends to existing algorithm unrolling approaches, enhancing reconstruction quality without increasing the computational complexity significantly. 2025-10-18T03:10:09Z Neural Information Processing Systems (NeurIPS), 2025 Junno Yun Yaşar Utku Alçalar Mehmet Akçakaya http://arxiv.org/abs/2510.16256v1 Functional Spectral Imaging by Ultrasound (FSIU): A Spectral-Theoretic Basis for Functional Ultrasound 2025-10-17T23:04:19Z Functional Spectral Imaging (FSI) models image formation as the recovery of tissue surrogates such as density and stiffness from spectral perturbations of a self-adjoint elliptic operator. Rather than relying on reflectivity or relaxation kinetics, FSI tracks shifts of a truncated set of eigenmodes under controlled excitation, providing a non-ionizing and operator-theoretic route to contrast. Tissue heterogeneity is modeled as a small perturbation of L = -div(D grad) + gamma, with first-order Hadamard formulas linking local contrasts to eigenvalue shifts. Frechet derivatives and their adjoints yield gradients for variational inversion, stabilized by Tikhonov or total-variation regularization and modal truncation. Finite-element simulations show submillimetric localization (about 0.1-0.3 mm) and milligram-scale detectability (thresholds near 1 mg) under ideal noise. Retaining 10-15 modes preserves about 85 percent of anomaly contrast while suppressing noise. A spectral-entropy index separates compact from diffuse inclusions and acts as a morphology surrogate. FSI thus provides a mathematically controlled, non-ionizing framework for localized functional imaging, motivating validation in physical phantoms and in vivo studies. 2025-10-17T23:04:19Z 18 pages, 7 figures. Theoretical and computational study introducing Functional Spectral Imaging by Ultrasound (FSIU), a spectral-operator framework for non-ionizing functional ultrasound Cesar Mello Fernando Medina da Cunha http://arxiv.org/abs/2506.15762v2 Implicit neural representations for accurate estimation of the standard model of white matter 2025-10-17T15:52:31Z Diffusion magnetic resonance imaging (dMRI) enables non-invasive investigation of tissue microstructure. The Standard Model (SM) of white matter aims to disentangle dMRI signal contributions from intra- and extra-axonal water compartments. However, due to the model its high-dimensional nature, accurately estimating its parameters poses a complex problem and remains an active field of research, in which different (machine learning) strategies have been proposed. This work introduces an estimation framework based on implicit neural representations (INRs), which incorporate spatial regularization through the sinusoidal encoding of the input coordinates. The INR method is evaluated on both synthetic and in vivo datasets and compared to existing methods. Results demonstrate superior accuracy of the INR method in estimating SM parameters, particularly in low signal-to-noise conditions. Additionally, spatial upsampling of the INR can represent the underlying dataset anatomically plausibly in a continuous way. The INR is self-supervised, eliminating the need for labeled training data. It achieves fast inference, is robust to noise, supports joint estimation of SM kernel parameters and the fiber orientation distribution function with spherical harmonics orders up to at least 8, and accommodates gradient non-uniformity corrections. The combination of these properties positions INRs as a potentially important tool for analyzing and interpreting diffusion MRI data. 2025-06-18T15:40:42Z Tom Hendriks Gerrit Arends Edwin Versteeg Anna Vilanova Maxime Chamberland Chantal M. W. Tax 10.1038/s42003-025-09399-5 http://arxiv.org/abs/2510.12852v2 Quantum Mechanical Analysis of Neutron Wavefunction Overlap and Nuclear Interaction Probability with Carborane Cage ($^{10}$B10) in Boron Neutron Capture Therapy 2025-10-17T15:03:36Z Boron neutron capture therapy (BNCT) leverages the nuclear reaction between thermal neutrons and boron-10 (B-10) atoms to induce selective tumor cell death. The spatial and quantum mechanical overlap between the neutron wavefunction and B-10 nuclei encapsulated in carborane cages (C2B10H12) is fundamental to optimizing therapeutic efficacy. This study presents a quantum mechanical framework to evaluate the neutron-boron interaction probability by modeling neutron wavefunctions and the spatial distribution of boron atoms within the carborane cages. Using spherical harmonics and density functional theory (DFT)-derived geometries of carborane, the neutron scattering amplitudes and reaction cross sections are quantitatively analyzed. The implications of neutron spin states, nuclear magnetic moments, and external perturbations on the neutron capture probability are discussed. The computed neutron scattering amplitudes and reaction cross sections provide a basis for evaluating neutron-boron interaction probabilities under varied quantum conditions. The proposed model offers theoretical insights into molecular-level design considerations for enhancing the efficiency of BNCT. 2025-10-14T09:00:49Z 9 pages, 0 figures Hung-Te Henry Su Chih-Hsueh Lin Po-Han Lee http://arxiv.org/abs/2411.16039v2 Label-Free Intraoperative Imaging of Hemodynamics using Deep Learning 2025-10-17T14:01:09Z Intraoperative visualization of hemodynamics is crucial for accurate diagnosis and informed surgical decision-making. In neurosurgery, indocyanine green fluorescence imaging (ICG-FI) is the gold standard for assessing blood flow and identifying vascular structures. However, it is limited by time-consuming data acquisition, mandatory waiting periods, potential allergic reactions, and operational complexities. Label-free alternatives, such as laser speckle contrast imaging (LSCI) and white light imaging (WLI), offer real-time vascular assessment but cannot resolve arterial-venous differentiation or blood flow direction determination. To address these challenges, we present a label-free cross-modal generation framework to synthesize mean transition time (MTT) maps from LSCI and WLI. MTT maps encode local hemodynamics, enabling artery-vein differentiation and flow direction inference. Experimental validation in rat brains demonstrates that the proposed method presents clear vasculature delineation, accurate artery-vein differentiation, and reliable blood flow direction decoding, while reducing total imaging time by 95.8% compared to conventional ICG protocols. This approach offers a fast, efficient, and contrast-free solution for continuous intraoperative surgical guidance. 2024-11-25T02:03:49Z Yan Shi Denghui Zhao Jingyi Yu Wei Ni Pengcheng Li Yun Gu Peng Miao Shanbao Tong http://arxiv.org/abs/2410.13361v2 On the new and accurate (Goudsmit-Saunderson) model for describing e-/e+ multiple Coulomb scattering (Geant4 Technical Note) 2025-10-17T13:02:00Z A new model, for the accurate simulation of multiple Coulomb scattering (MSC) of e-/e+, has been implemented in Geant4 recently and made available with version Geant4-10.4. The model is based on Goudsmit-Saunderson (GS) angular distributions computed by utilising the screen Rutherford (SR) DCS and follows very closely the formulation developed by Kawrakow [1, 2] and utilised in the EGSnrc toolkit [3]. Corrections, for taking into accountenergy loss [2] neglected by the GS theory, spin-relativistic effects [3] not included in the SR but might be accounted on the basis of Mott DCS as well as the so-called scattering power correction [4], i.e. appropriately incorporating deflections due to sub-threshold delta ray productions, are all included similarly to the EGSnrc model [3]. Furthermore, an accurate electron-step algorithm [5, 6, 2] is utilised for path length correction, i.e. for calculating the post-step position in each condensed history simulation steps such that the corresponding single-scattering longitudinal and lateral (post step point) distributions are very well reproduced. An e-/e+ stepping algorithm, including the simulation step-limit due to the MSC and boundary crossing [2]), free from step-size artefacts, makes the model complete. Details on this new model, including all the above-mentioned components and corrections, are provided in this Geant4 technical note. It must be noted, that a Goudsmit-Saunderson model for MSC was available before Geant4-10.4., documented in [7], that has been completely replaced by the model described in this technical note (keeping only the G4GoudsmitSaundersonMscModel name of the C++ class from that previous version) 2024-10-17T09:14:13Z Mihaly Novak http://arxiv.org/abs/2510.15562v1 Airway Mucus Rheology: Physical Insights for Navigating through Health to Pathology and Clinical Applications 2025-10-17T11:47:30Z Airway mucus is a complex gel with an anisotropic three-dimensional network structure. As a crucial component of the respiratory defense barrier, it plays a vital role in maintaining airway hydration and supporting the function of airway epithelial cells. Through linear and nonlinear rheological mechanisms such as ciliary motion and coughing, airway mucus expels foreign pathogens and toxic nano- and microparticles while selectively allowing the passage of specific nutrients and proteins. These protective and clearance functions depend on the proper rheological properties of mucus under normal physiological conditions. However, in respiratory disease such as CF, COPD, asthma, and COVID-19, excessive mucus secretion is often accompanied by abnormal rheological behaviors. This leads to impaired mucus flow, airway obstruction, and potentially life-threatening conditions. Therefore, this review examines the rheological behaviors of airway mucus in relation to health and disease, focusing on both macrorheology and microrheology. The review highlights those changes in the chemical composition and microstructure of airway mucus, especially under pathological conditions, that can significantly alter its rheological behavior. Rheological parameters can also serve as biological indicators to study the role of mucus in clearance functions and aid in developing pulmonary drug delivery systems. By integrating findings from both macro- and microrheological studies, this review aims to enhance our understanding of the complex behavior of airway mucus, supporting better diagnosis, treatment, and management of chronic respiratory diseases. 2025-10-17T11:47:30Z Zhiwei Liu Bo Che Hailin Zhang Linhong Deng http://arxiv.org/abs/2510.15478v1 Sparing of DNA irradiated with Ultra-High Dose-Rates under Physiological Oxygen and Salt conditions 2025-10-17T09:41:45Z Cancer treatment with radiotherapy aims to kill tumor cells and spare healthy tissue.Thus,the experimentally observed sparing of healthy tissue by the FLASH effect during irradiations with ultra-high dose rates (UHDR) enables clinicians to extend the therapeutic window.However, the underlying radiobiological and chemical mechanisms are far from being understood.DNA is one of the main molecular targets for radiotherapy.Ionizing radiation damage to DNA in water depends strongly on salt,pH,buffer and oxygen content of the solvent.Here we present a study of plasmid DNA pUC19,irradiated with 18MeV electrons at low dose rates (LDR) and UHDR under tightly controlled ambient and physiological oxygen conditions in PBS at pH 7.4.For the first time a sparing effect of DNA strand-break induction between UHDR(>10MGy/s) and LDR(<0.1Gy/s) irradiated plasmid DNA under physiological oxygen, salt and pH is observed for total doses above 10Gy.Under physiological oxygen (physoxia,5%O2,40mmHg),more single (SSB) and double strand-breaks (DSB) are observed when exposed to LDR, than to UHDR.This behaviour is absent for ambient oxygen (normoxia,21%O2,150-160mmHg).The experiments are accompanied by TOPAS-nBio based particle-scattering and chemical MCS to obtain information about the yields of reactive oxygen species (ROS).Hereby,an extended set of chemical reactions was considered, which improved upon the discrepancy between experiment and simulations of previous works, and allowed to predict DR dependent g-values of hydrogen peroxide (H2O2).To explain the observed DNA sparing effect under FLASH conditions at physoxia,the following model was proposed:The interplay of O2 with OH induced H-abstraction at the phosphate backbone,and the conversion of DNA base-damage to SSB,under consideration of the dose-rate dependent H3O+ yield via beta elimination processes is accounted for, to explain the observed behavior. 2025-10-17T09:41:45Z 34 pages, 12 figures Marc Benjamin Hahn Institut für Chemie, Universität Potsdam, Karl-Liebknecht-Str. 24-25, 14476 Potsdam, Germany Sepideh Aminzadeh-Gohari Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Anna Grebinyk Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Matthias Gross Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Andreas Hoffmann Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Xiangkun Li Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Anne Oppelt Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Chris Richard Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Felix Riemer Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Frank Stephan Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Elif Tarakci Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany Daniel Villani Deutsches Elektronen-Synchrotron, DESY, Platanenallee 6, 15738 Zeuthen, Germany http://arxiv.org/abs/2510.15400v1 Robust High-Resolution Multi-Organ Diffusion MRI Using Synthetic-Data-Tuned Prompt Learning 2025-10-17T07:51:35Z Clinical adoption of multi-shot diffusion-weighted magnetic resonance imaging (multi-shot DWI) for body-wide tumor diagnostics is limited by severe motion-induced phase artifacts from respiration, peristalsis, and so on, compounded by multi-organ, multi-slice, multi-direction and multi-b-value complexities. Here, we introduce a reconstruction framework, LoSP-Prompt, that overcomes these challenges through physics-informed modeling and synthetic-data-driven prompt learning. We model inter-shot phase variations as a high-order Locally Smooth Phase (LoSP), integrated into a low-rank Hankel matrix reconstruction. Crucially, the algorithm's rank parameter is automatically set via prompt learning trained exclusively on synthetic abdominal DWI data emulating physiological motion. Validated across 10,000+ clinical images (43 subjects, 4 scanner models, 5 centers), LoSP-Prompt: (1) Achieved twice the spatial resolution of clinical single-shot DWI, enhancing liver lesion conspicuity; (2) Generalized to seven diverse anatomical regions (liver, kidney, sacroiliac, pelvis, knee, spinal cord, brain) with a single model; (3) Outperformed state-of-the-art methods in image quality, artifact suppression, and noise reduction (11 radiologists' evaluations on a 5-point scale, $p<0.05$), achieving 4-5 points (excellent) on kidney DWI, 4 points (good to excellent) on liver, sacroiliac and spinal cord DWI, and 3-4 points (good) on knee and tumor brain. The approach eliminates navigator signals and realistic data supervision, providing an interpretable, robust solution for high-resolution multi-organ multi-shot DWI. Its scanner-agnostic performance signifies transformative potential for precision oncology. 2025-10-17T07:51:35Z 43 pages, 27 figures Chen Qian Haoyu Zhang Junnan Ma Liuhong Zhu Qingrui Cai Yu Wang Ruibo Song Lv Li Lin Mei Xianwang Jiang Qin Xu Boyu Jiang Ran Tao Chunmiao Chen Shufang Chen Dongyun Liang Qiu Guo Jianzhong Lin Taishan Kang Mengtian Lu Liyuan Fu Ruibin Huang Huijuan Wan Xu Huang Jianhua Wang Di Guo Hai Zhong Jianjun Zhou Xiaobo Qu http://arxiv.org/abs/2510.15279v1 Mechanics-guided parametric modeling of intranasal spray devices and formulations for targeted drug delivery to the nasopharynx 2025-10-17T03:38:05Z Improving the efficacy of nasal sprays by enhancing targeted drug delivery to intra-airway tissue sites prone to infection onset is hypothesized to be achievable through an optimization of key device and formulation parameters, such as the sprayed droplet sizes, spray cone angle, and formulation density. This study focuses on the nasopharynx, a primary locus of early viral entry, as the optimal target for intranasal drug delivery. 3D anatomical upper airway geometries reconstructed from high-resolution computed tomography scans were used to numerically evaluate a cone injection approach, with inert particles mimicking the motion of sprayed droplets within an underlying inhaled airflow field. We have considered monodisperse sprayed particles sized between 10 to 50 microns, six densities ranging from 1.0 to 1.5 g/ml for the constituent formulation, and twelve plume angles spanning 1 to 70 degrees subtended by the spray jet at the nozzle position. Large Eddy Simulation-based modeling of the inhaled airflow physics within the anatomical domains was coupled with a Lagrangian particle-tracking framework to derive the drug deposition trend at the nasopharynx. The resulting globally averaged deposition contour map, obtained by interpolating the outcomes for the discrete test parameters, revealed that nasopharyngeal deposition peaked for droplet sizes 25 to 45 microns and plume angles equal to or less than 30 degrees. In addition, the formulation density of 1.0 g/ml yielded the highest mean deposition rate, over the tested range of sprayed particle sizes and plume angles. The findings were experimentally validated through representative physical spray tests conducted in a 3D-printed replica of one of the test geometries and collectively demonstrate that rational optimization of the intranasal spray design is attainable, with substantial enhancement of targeted drug delivery to the nasopharynx. 2025-10-17T03:38:05Z 23 pages, 10 figures Md Tariqul Hossain Abir Malakar Mohammad Yeasin William O'Connell Mohammad Mehedi Hasan Akash Azadeh Borojeni Devranjan Samanta Gerallt Williams Joshua Reineke Goncalo Farias Sunghwan Jung Julie Suman Saikat Basu 10.3389/fddev.2025.1721960 http://arxiv.org/abs/2510.15179v1 An Advanced Two-Stage Model with High Sensitivity and Generalizability for Prediction of Hip Fracture Risk Using Multiple Datasets 2025-10-16T22:44:51Z Hip fractures are a major cause of disability, mortality, and healthcare burden in older adults, underscoring the need for early risk assessment. However, commonly used tools such as the DXA T-score and FRAX often lack sensitivity and miss individuals at high risk, particularly those without prior fractures or with osteopenia. To address this limitation, we propose a sequential two-stage model that integrates clinical and imaging information to improve prediction accuracy. Using data from the Osteoporotic Fractures in Men Study (MrOS), the Study of Osteoporotic Fractures (SOF), and the UK Biobank, Stage 1 (Screening) employs clinical, demographic, and functional variables to estimate baseline risk, while Stage 2 (Imaging) incorporates DXA-derived features for refinement. The model was rigorously validated through internal and external testing, showing consistent performance and adaptability across cohorts. Compared to T-score and FRAX, the two-stage framework achieved higher sensitivity and reduced missed cases, offering a cost-effective and personalized approach for early hip fracture risk assessment. Keywords: Hip Fracture, Two-Stage Model, Risk Prediction, Sensitivity, DXA, FRAX 2025-10-16T22:44:51Z 38 pages, 3 figures, 8 tables. This is a preprint version of the manuscript titled "An Advanced Two-Stage Model with High Sensitivity and Generalizability for Prediction of Hip Fracture Risk Using Multiple Datasets." The paper is currently under journal submission Shuo Sun Meiling Zhou Chen Zhao Joyce H. Keyak Nancy E. Lane Jeffrey D. Deng Kuan-Jui Su Hui Shen Hong-Wen Deng Kui Zhang Weihua Zhou