https://arxiv.org/api/D44kalaDHre5hwIoYfeX/u1Ugm82026-06-25T16:46:46Z900781015http://arxiv.org/abs/2507.02367v2A robust and versatile deep learning model for prediction of the arterial input function in dynamic small animal $\left[^{18}\text{F}\right]$FDG PET imaging2025-10-23T20:31:53ZDynamic positron emission tomography (PET) and kinetic modeling are pivotal in advancing tracer development research in small animal studies. Accurate kinetic modeling requires precise input function estimation, traditionally achieved via arterial blood sampling. However, arterial cannulation in small animals like mice, involves intricate, time-consuming, and terminal procedures, precluding longitudinal studies. This work proposes a non-invasive, fully convolutional deep learning-based approach (FC-DLIF) to predict input functions directly from PET imaging, potentially eliminating the need for blood sampling in dynamic small-animal PET. The proposed FC-DLIF model includes a spatial feature extractor acting on the volumetric time frames of the PET sequence, extracting spatial features. These are subsequently further processed in a temporal feature extractor that predicts the arterial input function. The proposed approach is trained and evaluated using images and arterial blood curves from [$^{18}$F]FDG data using cross validation. Further, the model applicability is evaluated on imaging data and arterial blood curves collected using two additional radiotracers ([$^{18}$F]FDOPA, and [$^{68}$Ga]PSMA). The model was further evaluated on data truncated and shifted in time, to simulate shorter, and shifted, PET scans. The proposed FC-DLIF model reliably predicts the arterial input function with respect to mean squared error and correlation. Furthermore, the FC-DLIF model is able to predict the arterial input function even from truncated and shifted samples. The model fails to predict the AIF from samples collected using different radiotracers, as these are not represented in the training data. Our deep learning-based input function offers a non-invasive and reliable alternative to arterial blood sampling, proving robust and flexible to temporal shifts and different scan durations.2025-07-03T06:55:41Z21 pages, 14 figuresChristian SalomonsenLuigi T LuppinoFredrik AspheimKristoffer K. WickstrømElisabeth WetzerMichael C. KampffmeyerRodrigo BerzaghiRune SundsetRobert JenssenSamuel Kuttnerhttp://arxiv.org/abs/2510.20764v1Acoustic Emission Cascade Predicting Progression to Failure of Rock and Bone2025-10-23T17:36:30ZQuasi brittle materials such as rock and bone are understood to fail via microcrack coalescence. The accompanying Acoustic Emission (AE) event rate is known to increase as failure progresses. Here we examine the progression of the AE event rate for both rock and bone under conditions where failure progresses under fixed loading. The experiments for rock entail subjecting granite beams to a fixed loading under three point bending and monitoring the time-dependent failure. For bone, human cadaver skulls are loaded under pinning loads similar to those used for immobilization of the head for neurosurgical procedures. AE rates are shown to be consistent with a rate dependent material failure law including a quasi-linear cascade of the inverse AE energy rate in the lead up to failure that is shown here to arise because of a coupling wherein a response rate is a power law of a driver and the driver is, in turn, a power law of the accumulated response. For both materials and experimental configurations this cascade provides warning of impending failure. For granite beams there is accurate prediction of failure time over the final 30 percent of the specimens lifetimes, which ranged from 35 seconds to two days. For skull fracture, the commencement of the failure cascade provides 30-70 seconds for warning of failure, which would be sufficient for basic remedial action to avoid patient injury in a surgical application.2025-10-23T17:36:30Z29 pages, 13 figuresAndrew P. BungerYunxing LuAyyaz MustafaMichael M. McDowellhttp://arxiv.org/abs/2508.09285v4Simulation of Repair on Dynamic Patient-Specific Left Atrioventricular Valve Models2025-10-23T15:27:30ZPurpose: To develop and evaluate a dynamic, image-derived patient-specific physical simulation platform for the assessment of left atrioventricular valve (LAVV) repair strategies in pediatric patients with repaired atrioventricular canal defects. Methods: 3D transesophageal echocardiographic images of two patients with regurgitant LAVVs were identified from an institutional database. Custom code in SlicerHeart was used to segment leaflets, define the annulus, and generate patient-specific valve molds. Silicone valve models were fabricated and tested in a pulse duplicator under simulated physiological conditions. Five unrepaired valves were analyzed for manufacturing consistency, and multiple surgical repair techniques were compared for two patient-specific models. Results: Manufacturing variability was low in annular metrics (CV for annular circumference: 2.1; commissural distance: 4.1; annulus height: 14.7) but higher in leaflet closure metrics (billow height: 11.1%; billow volume: 18.9%; tenting height: 45.9%; tenting volume: 73.5%). In Patient 1, cleft closure and an Alfieri stitch both eliminated the regurgitant orifice area, but the Alfieri stitch resulted in elevated mean pressure gradient (17 mmHg vs. 4-9 mmHg for other repairs) and deteriorated with repeated loading. In Patient 2, no repair eliminated regurgitation entirely; however, combining an 11 mm patch augmentation with commissuroplasty reduced regurgitant area to 0.147 cm2, the smallest observed among tested strategies. Conclusion: This study demonstrates the feasibility of a dynamic physical simulation platform for preclinical LAVV repair evaluation. This proof-of-concept work highlights the platform potential for refining repair strategies before clinical application, which may be particularly relevant in small and heterogeneous populations with congenital heart disease.2025-08-12T18:45:16Z23 pages, 5 figuresStephen ChingChristopher ZelonisChristian HerzPatricia SabinMatthew DaemerMuhammad NuriYan WangDevin W. LaurenceJonathan M. ChenLindsay S. RogersMichael D. QuartermainJohn MooreTerry PetersElvis ChenMatthew A. Jolleyhttp://arxiv.org/abs/2505.19256v5PolyPose: Deformable 2D/3D Registration via Polyrigid Transformations2025-10-23T14:17:27ZDetermining the 3D pose of a patient from a limited set of 2D X-ray images is a critical task in interventional settings. While preoperative volumetric imaging (e.g., CT and MRI) provides precise 3D localization and visualization of anatomical targets, these modalities cannot be acquired during procedures, where fast 2D imaging (X-ray) is used instead. To integrate volumetric guidance into intraoperative procedures, we present PolyPose, a simple and robust method for deformable 2D/3D registration. PolyPose parameterizes complex 3D deformation fields as a composition of rigid transforms, leveraging the biological constraint that individual bones do not bend in typical motion. Unlike existing methods that either assume no inter-joint movement or fail outright in this under-determined setting, our polyrigid formulation enforces anatomically plausible priors that respect the piecewise-rigid nature of human movement. This approach eliminates the need for expensive deformation regularizers that require patient- and procedure-specific hyperparameter optimization. Across extensive experiments on diverse datasets from orthopedic surgery and radiotherapy, we show that this strong inductive bias enables PolyPose to successfully align the patient's preoperative volume to as few as two X-rays, thereby providing crucial 3D guidance in challenging sparse-view and limited-angle settings where current registration methods fail. Additional visualizations, tutorials, and code are available at https://polypose.csail.mit.edu.2025-05-25T18:24:18ZNeurIPS 2025. Code available at https://github.com/eigenvivek/polyposeVivek GopalakrishnanNeel DeyPolina Gollandhttp://arxiv.org/abs/2510.20391v1Contrast-enhanced X-ray imaging of articular cartilage: reliability of a cationic contrast agent in combination with high-resolution peripheral quantitative computed tomography system2025-10-23T09:40:15ZArticular cartilage showcases distinctive mechanical behaviour, attributable to its biphasic composition and hierarchical organization. Proteoglycans, essential constituents of the extracellular matrix, contribute to tissue swelling, stiffness, and viscoelasticity, thanks to the fixed charge density. Degenerative alterations in proteoglycan content and collagen structure - key indicators of diseases such as osteoarthritis - compromise the mechanical integrity of articular cartilage, underscoring the importance of early detection. Although magnetic resonance imaging provides valuable compositional information, its limited spatial resolution restricts its effectiveness in evaluating thin soft tissues such as articular cartilage. As an alternative, contrast-enhanced X-ray imaging circumvents such limitation, resorting to the use of radiopaque contrast agents. In this context, cationic contrast agents, like CA4+, enable the quantitative assessment of proteoglycan content via electrostatic attraction. High-resolution peripheral quantitative computed tomography offers an optimal compromise between spatial resolution and radiation exposure, making it a promising tool for clinical use. This study aimed to explore the relationship between proteoglycan content - quantified through contrast-enhanced high-resolution peripheral quantitative computed tomography combined with the use of CA4+ - and the viscoelastic properties of healthy bovine articular cartilage, assessed via indentation testing. Results highlighted significant correlations between the enhanced radiopacity of articular cartilage, ascribable to the PG content, with parameters representing the mechanical response of the tissue.2025-10-23T09:40:15Z12 pages, 2 figures, 5 tablesS. FantoniLaboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyM. BerniLaboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyR. FognaniLaboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyG. FraterrigoLaboratorio di BioIngegneria Computazionale, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyP. CardarelliIstituto Nazionale di Fisica NucleareF. BaruffaldiLaboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyM. BaleaniLaboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italyhttp://arxiv.org/abs/2510.20148v1Understanding Mechanistic Role of Structural and Functional Connectivity in Tau Propagation Through Multi-Layer Modeling2025-10-23T02:52:42ZEmerging neuroimaging evidence shows that pathological tau proteins build up along specific brain networks, suggesting that large-scale network architecture plays a key role in the progression of Alzheimer's disease (AD). However, how structural connectivity (SC) and functional connectivity (FC) interact to influence tau propagation remains unclear. Leveraging an unprecedented volume of longitudinal neuroimaging data, we examine SC-FC interactions through a multi-layer graph diffusion model. Beyond showing that connectome architecture constrains tau spread, our model reveals a regionally asymmetric contribution of SC and FC. Specifically, FC predominantly drives tau spread in subcortical areas, the insula, frontal and temporal cortices, whereas SC plays a larger role in occipital, parietal, and limbic regions. The relative dominance of SC versus FC shifts over the course of disease, with FC generally prevailing in early AD and SC becoming primary in later stages. Spatial patterns of SC- and FC-dominant regions strongly align with the regional expression of AD-associated genes involved in inflammation, apoptosis, and lysosomal function, including CHUK (IKK-alpha), TMEM106B, MCL1, NOTCH1, and TH. In parallel, other non-modifiable risk factors (e.g., APOE genotype, sex) and biological mechanisms (e.g., amyloid deposition) selectively reshape tau propagation by shifting dominant routes between anatomical and functional pathways in a region-specific manner. Findings are validated in an independent AD cohort.2025-10-23T02:52:42Z42 pages, 14 figures, 64 referencesTingting DanXinwei HuangJiaqi DingYinggang ZhengGuorong Wuhttp://arxiv.org/abs/2510.16213v2Phase-sensitive modelling improves Fat DESPOT multiparametric relaxation mapping in fat-water mixtures2025-10-22T04:04:42ZPurpose: To improve on the original form of Fat DESPOT, a multiparametric mapping technique that returns the fat- and water-specific estimates of $R_1$ ($R_{1f}$, $R_{1w}$), $R_2^*$ , and proton density fat fraction (PDFF) by upgrading the fat-water separation method used for selection of initial parameter guesses, and by introducing explicit model sensitivity to the phase of the water and fat signals. Methods: We compared the 3-point Dixon and Graph Cut (GC) approaches to initial guesses for Fat DESPOT in phantom experiments at 3 T in a variable fat fraction gel phantom. Also in phantom, we then compared the original Fat DESPOT approach to a magnitude approach modelling the phases of fat and water separately (Fat DESPOT$_{mφ}$), and an approach that models the complex data (Fat DESPOT$_c$). The best-performing approach was then used in the lower leg of a healthy human participant. Results: In phantoms, Fat DESPOT using the 3-point Dixon and GC performed similarly in parametric estimates and precision, though the Dixon approach deviated from the overall trend in the 50% nominal fat fraction ROI. Furthermore, Fat DESPOT$_c$ showed the best agreement with reference PDFF (average error 1.5 +/- 1.2%) and the lowest combined standard deviation across ROIs, for PDFF, $R_{1f}$, and $R_{1w}$ (σ = 0.13%, 0.19 s$^{-1}$, 0.0082 s$^{-1}$). Conclusion: With a higher precision of $R_{1f}$ and $R_{1w}$ , accuracy of PDFF, and more echo time versatility than other compared approaches, this work demonstrates the advantages of the GC approach for initial guesses paired with complex fitting for Fat DESPOT multiparametric imaging.2025-10-17T20:58:11ZRenée-Claude BiderCristian CiobanuJorge Campos PazmiñoVéronique FortierEvan McNabbIves R. Levesquehttp://arxiv.org/abs/2510.19213v1AI in Proton Therapy Treatment Planning: A Review2025-10-22T03:48:52ZPurpose: Proton therapy provides superior dose conformity compared to photon therapy, but its treatment planning is challenged by sensitivity to anatomical changes, setup/range uncertainties, and computational complexity. This review evaluates the role of artificial intelligence (AI) in improving proton therapy treatment planning. Materials and methods: Recent studies on AI applications in image reconstruction, image registration, dose calculation, plan optimization, and quality assessment were reviewed and summarized by application domain and validation strategy. Results: AI has shown promise in automating contouring, enhancing imaging for dose calculation, predicting dose distributions, and accelerating robust optimization. These methods reduce manual workload, improve efficiency, and support more personalized planning and adaptive planning. Limitations include data scarcity, model generalizability, and clinical integration. Conclusion: AI is emerging as a key enabler of efficient, consistent, and patient-specific proton therapy treatment planning. Addressing challenges in validation and implementation will be essential for its translation into routine clinical practice.2025-10-22T03:48:52ZYuzhen DingHongying FengMartin BuesMirek FatygaTianming LiuThomas J. WhitakerHaibo LinNancy Y. LeeCharles B. SimoneSamir H. PatelDaniel J. MaSteven J. FrankSujay A. VoraJonathan A. AshmanWei Liuhttp://arxiv.org/abs/2502.15405v3Concussion and head acceleration exposure in elite rugby union and American football: Interpreting indicative trends2025-10-21T07:10:16ZElite-level American football and rugby union are two high-contact sports with growing clinical and legal concerns over player safety. A comparison of current indicative trends in concussion and head acceleration events (HAEs) in elite-level American football and rugby union was undertaken. Rugby union players have a greater number of professional playing years and matches available in a season than their American football counterparts. Rugby union players have a greater number of concussions reported per match and a higher proportion of concussions occurring during training sessions, based on National Football League (NFL) and Rugby Football Union (RFU) injury reports. Preliminary findings indicate that rugby union forwards experience a higher incidence of HAEs per player match over lower and higher magnitude thresholds, than American football defensive players. Taken collectively, current evidence indicates a trend toward greater reported exposure in elite-level rugby union across several key metrics. These patterns highlight the need for independent, transparent, and scientifically rigorous research to better understand concussion and HAE biomechanics and to support the development of effective mitigation strategies in contact sport.2025-02-21T12:11:10ZGregory Tierneyhttp://arxiv.org/abs/2510.18210v1Applying voxel-based analysis to oropharyngeal cancer proton therapy patients: a correlation study on radiation-induced acute dysphagia2025-10-21T01:26:45ZBackground: Voxel-based analysis (VBA) is an analytic approach to evaluate correlations between local dose and the development of different toxicities. DVHs are used for toxicity prediction as well. Compared with DVH, no contours are required for VBA technique and results tell specific voxels that may be related to the toxicity instead of the whole contoured area. The VBA has been used on different cancer sites and for different toxicities. Most of these studies included patients treated with photon, all published studies were based on planned dose and VBA tools used were developed in house. In our study, patient cohort were treated with proton, our VBA tool was developed based on RayStation and doses fed to the VBA tool were delivered doses with constant and two variable RBE models.2025-10-21T01:26:45ZQianxia WangAlexander StanforthWilliam Andrew LePainEdgar GeloverHaijian ChenMingyao ZhuKatja M. LangenMark McDonaldJames Edward BatesStella Flampourihttp://arxiv.org/abs/2510.13658v2Spherical Radiomics -- A Novel Approach to Glioblastoma Radiogenomic Analysis of Heterogeneity2025-10-20T19:14:53ZWe develop and validate a novel spherical radiomics framework for predicting key molecular biomarkers using multiparametric MRI. Conventional Cartesian radiomics extract tumor features on orthogonal grids, which do not fully capture the tumor's radial growth patterns and can be insensitive to evolving molecular signatures. In this study, we analyzed GBM radiomic features on concentric 2D shells, which were then mapped onto 2D planes for radiomics analysis. Radiomic features were extracted using PyRadiomics from four different regions in GBM. Feature selection was performed using ANOVA F-statistics. Classification was conducted with multiple machine-learning models. Model interpretability was evaluated through SHAP analysis, clustering analysis, feature significance profiling, and comparison between radiomic patterns and underlying biological processes. Spherical radiomics consistently outperformed conventional 2D and 3D Cartesian radiomics across all prediction tasks. The best framework reached an AUC of 0.85 for MGMT, 0.80 for EGFR, 0.80 for PTEN, and 0.83 for survival prediction. GLCM-derived features were identified as the most informative predictors. Radial transition analysis using the Mann-Whitney U-test demonstrates that transition slopes between T1-weighted contrast-enhancing and T2/FLAIR hyperintense lesion regions, as well as between T2 intense lesion and a 2 cm peritumoral expansion region, are significantly associated with biomarker status. Furthermore, the observed radiomic changes along the radial direction closely reflected known biological characteristics. Radiomic features extracted on the spherical surfaces at varying radial distances to the GBM tumor centroid are better correlated with important tumor molecular markers and patient survival than the conventional Cartesian analysis.2025-10-15T15:19:28ZHaotian FengKe Shenghttp://arxiv.org/abs/2308.02724v2A Tracking prior to Localization workflow for Ultrasound Localization Microscopy2025-10-20T14:09:24ZUltrasound Localization Microscopy (ULM) has proven effective in resolving microvascular structures and local mean velocities at sub-diffraction-limited scales, offering high-resolution imaging capabilities. Dynamic ULM (DULM) enables the creation of angiography or velocity movies throughout cardiac cycles. Currently, these techniques rely on a Localization-and-Tracking (LAT) workflow consisting in detecting microbubbles (MB) in the frames before pairing them to generate tracks. While conventional LAT methods perform well at low concentrations, they suffer from longer acquisition times and degraded localization and tracking accuracy at higher concentrations, leading to biased angiogram reconstruction and velocity estimation. In this study, we propose a novel approach to address these challenges by reversing the current workflow. The proposed method, Tracking-and-Localization (TAL), relies on first tracking the MB and then performing localization. Through comprehensive benchmarking using both in silico and in vivo experiments and employing various metrics to quantify ULM angiography and velocity maps, we demonstrate that the TAL method consistently outperforms the reference LAT workflow. Moreover, when applied to DULM, TAL successfully extracts velocity variations along the cardiac cycle with improved repeatability. The findings of this work highlight the effectiveness of the TAL approach in overcoming the limitations of conventional LAT methods, providing enhanced ULM angiography and velocity imaging.2023-08-04T22:01:32ZIEEE Transactions on Medical Imaging 44 (2025) 698-710Alexis LeconteJonathan PoréeBrice RaubyAlice WuNin GhigoPaul XingChloé BourquinGerardo Ramos-PalaciosAbbas F. SadikotJean Provost10.1109/TMI.2024.3456676http://arxiv.org/abs/2510.17456v1Inverse Optimal Control of Muscle Force Sharing During Pathological Gait2025-10-20T11:41:30ZMuscle force sharing is typically resolved by minimizing a specific objective function to approximate neural control strategies. An inverse optimal control approach was applied to identify the "best" objective function, among a positive linear combination of basis objective functions, associated with the gait of two post-stroke males, one high-functioning (subject S1) and one low-functioning (subject S2). It was found that the "best" objective function is subject- and leg-specific. No single function works universally well, yet the best options are usually differently weighted combinations of muscle activation- and power-minimization. Subject-specific inverse optimal control models performed best on their respective limbs (\textbf{RMSE 178/213 N, CC 0.71/0.61} for non-paretic and paretic legs of S1; \textbf{RMSE 205/165 N, CC 0.88/0.85} for respective legs of S2), but cross-subject generalization was poor, particularly for paretic legs. Moreover, minimizing the root mean square of muscle power emerged as important for paretic limbs, while minimizing activation-based functions dominated for non-paretic limbs. This may suggest different neural control strategies between affected and unaffected sides, possibly altered by the presence of spasticity. Among the 15 considered objective functions commonly used in inverse dynamics-based computations, the root mean square of muscle power was the only one explicitly incorporating muscle velocity, leading to a possible model for spasticity in the paretic limbs. Although this objective function has been rarely used, it may be relevant for modeling pathological gait, such as post-stroke gait.2025-10-20T11:41:30ZFilip BečanovićVincent BonnetKosta JovanovićSamer MohammedRaphaël Dumashttp://arxiv.org/abs/2510.17331v1A Review of Equation-Based and Data-Driven Reduced Order Models featuring a Hybrid cardiovascular application2025-10-20T09:24:46ZCardiovascular diseases are a leading cause of death in the world, driving the development of patient-specific and benchmark models for blood flow analysis. This chapter provides a theoretical overview of the main categories of Reduced Order Models (ROMs), focusing on both projection-based and data-driven approaches within a classical setup. We then present a hybrid ROM tailored for simulating blood flow in a patient-specific aortic geometry. The proposed methodology integrates projection-based techniques with neural network-enhanced data-driven components, incorporating a lifting function strategy to enforce physiologically realistic outflow pressure conditions. This hybrid methodology enables a substantial reduction in computational cost while mantaining high fidelity in reconstructing both velocity and pressure fields. We compare the full- and reduced-order solutions in details and critically assess the advantages and limitations of ROMs in patient-specific cardiovascular modeling.2025-10-20T09:24:46ZPierfrancesco SienaPasquale Claudio AfricaMichele GirfoglioGianluigi Rozzahttp://arxiv.org/abs/2510.17044v1Optimizing Transmission FLASH Radiotherapy for Large-Field Post-Mastectomy Breast Treatment2025-10-19T23:17:07ZWe investigated the effects of scanning speed, beam configuration, and dose-rate modeling on the FLASH effect in post-mastectomy proton transmission-beam (TB) planning and evaluated whether optimizing the spot-scanning path can enhance FLASH. Five left-sided post-mastectomy patients (32 Gy in 5 fractions) were replanned with single-energy (249 MeV) tangential TBs plus a clinical en face background beam. FLASH was evaluated with two models: Krieger's FLASH effectiveness model (FEM) and Folkerts' average dose-rate (ADR) framework. Plans used conventional pencil-beam scanning, split-field delivery, and GA-optimized spot sequences, with vertical scan speeds varied from 10 to 20 mm/ms. FLASH in normal tissues was defined as the percentage of voxels meeting the threshold (>= 4 Gy at >= 40 Gy/s); once a voxel met the criterion, a dose-adjustment factor of 0.67 was applied. The FLASH effect was highly sensitive to scanning pattern and model choice. Increasing vertical scan speed from 10 to 20 mm/ms increased FLASH in the CTV by 22% (ADR) and 12% (FEM); in skin it rose from 41.4% to 58.8% (ADR) and from 8.4% to 13.1% (FEM). Split-field delivery increased the temporal separation between vertical spot columns and yielded superior FLASH, including up to a 9.2 Gy reduction in CTV Dmean with ADR. GA-based optimization shortened scan time and achieved FLASH comparable to split-field delivery, with a CTV Dmean reduction of 7.87 Gy (ADR-GA) and skin Dmean reductions of 2-3 Gy. These findings indicate that FLASH outcomes depend strongly on scanning trajectory, scan speed, and model selection. In addition, path-minimizing spot-delivery optimization (e.g., GA) can further improve dose-rate distributions in healthy voxels.2025-10-19T23:17:07ZAhmal Jawad ZafarSunil William DuttaMatthew Joseph CaseZachary DiamondDuncan BohannonReshma JagsiXiaofeng YangJun Zhou