https://arxiv.org/api/K3UtPy+APyrPN0nKLqE1Qb0pYao 2026-06-25T15:25:16Z 9007 795 15 http://arxiv.org/abs/2505.03637v2 Servo navigation and phase equalization enhanced by run-time stabilization (PEERS) for 3D EPI time series 2025-10-27T21:48:54Z Purpose: To enhance time-resolved segmented imaging by synergy of run-time stabilization and retrospective, data-driven phase correction. Methods: A segmented 3D EPI sequence for fMRI time series is equipped with servo navigation based on short orbital navigators and a linear perturbation model, enabling run-time correction for rigid-body motion as well as bulk phase and frequency fluctuation. Complementary retrospective phase correction is based on the repetitive structure of the time series and serves to address residual phase and frequency offsets. The combined approach is termed phase equalization enhanced by run-time stabilization (PEERS). Results: The proposed strategy is evaluated in a phantom and in-vivo. Servo navigation is found to diminish motion confound in raw data and maintain k-space consistency over time series. In turn, retrospective phase equalization is found to eliminate shot-wise phase and frequency offsets relative to the navigator, which are attributed to eddy-currents and vibrations from phase encoding. Retrospective phase equalization reduces the precision requirements for run-time frequency control, supporting the use of short navigators. Relative to conventional volume realignment, PEERS achieved tSNR improvements up to $30\%$ for small motion and in the order of $10\%$ when volunteers tried to hold still. Retrospective phase equalization is found to clearly outperform phase correction based solely on navigator-based frequency estimates. Conclusion: Servo navigation achieves high-precision run-time motion correction for 3D EPI fMRI. Coarse frequency tracking based on short navigators is supplemented by precise retrospective frequency and phase correction. Fully automatic and self-calibrated, PEERS offers effective plug-and-play motion and phase correction for 3D fMRI. 2025-05-06T15:39:39Z to be submitted to Magnetic Resonance in Medicine (MRM) Malte Riedel Thomas Ulrich Samuel Bianchi Klaas P. Pruessmann http://arxiv.org/abs/2510.23876v1 Predicting Wrist Osteoporosis from excised human finger bones using spatially offset Raman spectroscopy, A Cadaveric Study 2025-10-27T21:31:14Z Osteoporosis and osteopenia remain vastly underdiagnosed. Current clinical screening relies almost exclusively on dual-energy X-ray absorptiometry (DXA), which measures bone mineral density (BMD) but fails to capture the compositional changes that lead to BMD loss. We investigated whether Spatially Offset Raman Spectroscopy (SORS) applied to excised finger bones can assess subsurface biochemical markers capable of diagnosing osteoporosis and osteopenia and predicting wrist DXA T-scores. Raman spectra were acquired ex vivo on the mid-shaft of the proximal phalanx of the second digit from 25 female cadavers spanning the three T-score categories (n=8 normal, n=6 osteopenic, and n=11 osteoporotic) at spatial offsets of 0, 3, and 6 mm from a laser irradiation spot. After normalizing spectra to the PO43- peak, group-averaged spectra of the three categories, measured at 3-mm offset, showed clear differences in the CO32-, Amide III, CH2, and Amide I bands. Quantitatively, four out of five mineral-to-matrix ratios differed significantly (p < 0.05) between normal and osteopenic bone, and between osteopenic and osteoporotic bone, and all five ratios showed significant differences between normal and osteoporotic bone. In contrast, the 0-mm offset suffered diminished contrast, and the 6-mm offset did not enhance discrimination between different groups, compared with the 3-mm offset. A leave-one-out, partial-least-squares regression model built from the 3-mm spectra predicted distal radius DXA T-score with a Pearson correlation of r = 0.85 and a root-mean-square error of cross-validation of 1 T-score units, correctly classifying 92% of specimens. 2025-10-27T21:31:14Z Mohammad Hosseini Sadia Afrin Anthony Yosick Emma Schenker Hani Awad Andrew J. Berger http://arxiv.org/abs/2510.23859v1 Low-Dose CT Imaging Using a Regularization-Enhanced Efficient Diffusion Probabilistic Model 2025-10-27T21:06:32Z Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting real-time applicability. We propose a Regularization-Enhanced Efficient Diffusion Probabilistic Model (RE-EDPM), a rapid and high-fidelity LDCT denoising framework that integrates a residual shifting mechanism to align low-dose and full-dose distributions and performs only four reverse diffusion steps using a Swin-based U-Net backbone. A composite loss combining pixel reconstruction, perceptual similarity (LPIPS), and total variation (TV) regularization effectively suppresses spatially varying noise while preserving anatomical structures. RE-EDPM was evaluated on a public LDCT benchmark across dose levels and anatomical sites. On 10 percent dose chest and 25 percent dose abdominal scans, it achieved SSIM = 0.879 (0.068), PSNR = 31.60 (2.52) dB, VIFp = 0.366 (0.121) for chest, and SSIM = 0.971 (0.000), PSNR = 36.69 (2.54) dB, VIFp = 0.510 (0.007) for abdomen. Visual and statistical analyses, including ablation and Wilcoxon signed-rank tests (p < 0.05), confirm significant contributions from residual shifting and regularization terms. RE-EDPM processes two 512x512 slices in about 0.25 s on modern GPUs, supporting near real-time clinical use. The proposed framework achieves an optimal balance between noise suppression and anatomical fidelity, offering an efficient solution for LDCT restoration and broader medical image enhancement tasks. 2025-10-27T21:06:32Z Qiang Li Mojtaba Safari Shansong Wang Huiqiao Xie Jie Ding Tonghe Wang Xiaofeng Yang http://arxiv.org/abs/2509.21697v2 Verification, Validation, and Uncertainty Quantification (VVUQ) of Physiologically Based Pharmacokinetic Models for Theranostic Digital Twins: Towards Reliable Model-Informed Treatment Planning for Radiopharmaceutical Therapies 2025-10-27T20:03:33Z Physiologically based pharmacokinetic (PBPK) models provide a mechanistic framework for simulating radiopharmaceutical kinetics and estimating patient-specific absorbed doses (ADs). PBPK models incorporate prior knowledge of patient physiology and drug-specific properties, which can enhance the models predictive performance. PBPK models can ultimately be used to predict treatment response and thereby enable theranostic digital twins (TDTs) for personalized treatment planning in radiopharmaceutical therapies (RPTs). To achieve this potential of precision RPT, however, the reliability of the underlying modeling, including the PBPK-based dosimetry, must be established through rigorous verification, validation, and uncertainty quantification (VVUQ). This review outlines the role of VVUQ in ensuring the credibility and clinical applicability of PBPK models in radiotheranostics. Key methodologies for PBPK model VVUQ are discussed, including goodness-of-fit (GOF) assessment, prediction evaluation, and uncertainty propagation. 2025-09-25T23:48:22Z Nouran R. R. Zaid Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA Deni Hardiansyah Medical Physics and Biophysics, Physics Department, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia Tahir Yusufaly Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA Arman Rahmim Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, BC, Canada Departments of Radiology and Physics, University of British Columbia, Vancouver, BC, Canada School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada http://arxiv.org/abs/2510.18141v2 Measuring multi-site pulse transit time with an AI-enabled mmWave radar 2025-10-27T18:45:36Z Pulse Transit Time (PTT) is a measure of arterial stiffness and a physiological marker associated with cardiovascular function, with an inverse relationship to diastolic blood pressure (DBP). We present the first AI-enabled mmWave system for contactless multi-site PTT measurement using a single radar. By leveraging radar beamforming and deep learning algorithms our system simultaneously measures PTT and estimates diastolic blood pressure at multiple sites. The system was evaluated across three physiological pathways - heart-to-radial artery, heart-to-carotid artery, and mastoid area-to-radial artery -- achieving correlation coefficients of 0.73-0.89 compared to contact-based reference sensors for measuring PTT. Furthermore, the system demonstrated correlation coefficients of 0.90-0.92 for estimating DBP, and achieved a mean error of -1.00-0.62 mmHg and standard deviation of 4.97-5.70 mmHg, meeting the FDA's AAMI guidelines for non-invasive blood pressure monitors. These results suggest that our proposed system has the potential to provide a non-invasive measure of cardiovascular health across multiple regions of the body. 2025-10-20T22:23:52Z Jiangyifei Zhu Kuang Yuan Akarsh Prabhakara Yunzhi Li Gongwei Wang Kelly Michaelsen Justin Chan Swarun Kumar http://arxiv.org/abs/2503.22640v2 Evaluation of a Novel Quantitative Multiparametric MR Sequence for Radiation Therapy Treatment Response Assessment 2025-10-27T17:26:31Z Purpose: To evaluate a Deep-Learning-enhanced MUlti-PArametric MR sequence (DL-MUPA) for treatment response assessment for brain metastases patients undergoing stereotactic radiosurgery (SRS) and head-and-neck (HnN) cancer patients undergoing conventionally fractionation adaptive radiation therapy. Methods: DL-MUPA derives quantitative T1 and T2 maps from a single 4-6-minute scan denoised via DL method using dictionary fitting. Phantom benchmarking was performed on a NIST-ISMRM phantom. Longitudinal patient data were acquired on a 1.5T MR-simulator, including pre-treatment (PreTx) and every 3 months after SRS (PostTx) in brain, and PreTx, mid-treatment and 3 months PostTx in HnN. Changes of mean T1 and T2 values were calculated within gross tumor volumes (GTVs), residual disease (RD, HnN), parotids, and submandibular glands (HnN) for treatment response assessment. Uninvolved normal tissues (normal appearing white matter in brain, masseter in HnN) were evaluated to as control. Results: Phantom benchmarking showed excellent inter-session repeatability (coefficient of variance <1% for T1, <7% for T2). Uninvolved normal tissue suggested acceptable in-vivo repeatability (brain |$Δ$|<6%, HnN |$Δ$T1|<7%, |$Δ$T2|<18% (4ms)). Remarkable changes were noted in resolved brain metastasis ($Δ$T1=14%) and necrotic settings ($Δ$T1=18-40%, $Δ$T2=9-41%). In HnN, two primary tumors showed T2 increase (PostTx GTV $Δ$T2>13%, RD $Δ$T2>18%). A nodal disease resolved PostTx (GTV $Δ$T1=-40%, $Δ$T2=-33%, RD $Δ$T1=-29%, $Δ$T2=-35%). Enhancement was found in involved parotids (PostTx $Δ$T1>12%, $Δ$T2>13%) and submandibular glands (PostTx $Δ$T1>15%, $Δ$T2>35%) while the uninvolved organs remained stable. Conclusions: DL-MUPA shows promise for treatment response assessment and identifying potential endpoints for functional sparing. 2025-03-28T17:30:09Z Yuhao Yan R. Adam Bayliss Adam R. Burr Andrew M. Baschnagel Brett A. Morris Florian Wiesinger Jose de Arcos Rodriguez Carri K. Glide-Hurst 10.1002/acm2.70274 http://arxiv.org/abs/2510.23290v1 Group-Level and Personalized Optimization for the Insula and Hippocampus Focal Electric Field in Transcranial Temporal Interferential Stimulation: A Computational Study 2025-10-27T13:00:28Z This study evaluated transcranial temporal interference stimulation (tTIS) for focal targeting of the insula and hippocampus, which are clinically relevant yet anatomically difficult to stimulate. Individualized and group-level electrode optimizations were compared to determine whether generalized montages can provide reliable targeting with reduced modeling demands. Sixty high-resolution head models (30 individuals and their mirrored counterparts) were constructed from T1- and T2-weighted MRI. Electric fields (EFs) were computed using the scalar-potential finite-difference method. Electrode montages and current ratios were optimized to minimize the root-mean-square error between simulated and target EF envelope (EFE) distributions, with a threshold of 0.3 V/m. Subsampling analysis was performed to estimate the number of models required for stable group-level outcomes. For the insula, a montage combining T7-P7 and Fp1-Fp2 achieved the highest focality, comparable to individualized results with reduced variability. For the hippocampus, the F7-T7 and T8-P8 montage gave the best group-level focality, though individualized optimization improved off-target suppression. Stable group-level patterns were obtained using 20 models for the insula and 9 for the hippocampus. Optimal tTIS montages depend on target depth. Group-level optimization suffices for cortical regions like the insula, whereas individualized tuning remains preferable for deeper targets such as the hippocampus. 2025-10-27T13:00:28Z 20 pages, 9 figures Taiga Inoue Naofumi Otsuru Akimasa Hirata http://arxiv.org/abs/2510.23244v1 Over four minutes relaxation of pyruvate using chemically and physically induced deceleration of relaxation 2025-10-27T12:06:03Z [1-13C]pyruvate is the most widely used tracer for hyperpolarized metabolic magnetic resonance imaging, with profound applications in tumor and inflammation diagnosis as well as treatment monitoring. The most fundamental hurdle to broader application, however, remains the rapid polarization relaxation and the associated signal loss. Here, we report a method to address this challenge. Studying the nuclear spin relaxation dispersion of [1-13C]pyruvate across magnetic fields from 8 μT to 9.4 T, as a function of additives, solvents, and preparation methods, allowed us to achieve relaxation times of up to four minutes. Such a long time could enable reliable quality control and nearly polarization loss-free transport, further boosting the power of hyperpolarized metabolic MRI. 2025-10-27T12:06:03Z 11 pages, 3 figures, 34 references Josh P. Peters Florin Teleanu Huijing Zou Ehtisham Rasool Jan-Bernd Hövener Alexej Jerschow Andrey N. Pravdivtsev http://arxiv.org/abs/2510.22605v1 Projection Embedded Diffusion Bridge for CT Reconstruction from Incomplete Data 2025-10-26T10:00:27Z Reconstructing CT images from incomplete projection data remains challenging due to the ill-posed nature of the problem. Diffusion bridge models have recently shown promise in restoring clean images from their corresponding Filtered Back Projection (FBP) reconstructions, but incorporating data consistency into these models remains largely underexplored. Incorporating data consistency can improve reconstruction fidelity by aligning the reconstructed image with the observed projection data, and can enhance detail recovery by integrating structural information contained in the projections. In this work, we propose the Projection Embedded Diffusion Bridge (PEDB). PEDB introduces a novel reverse stochastic differential equation (SDE) to sample from the distribution of clean images conditioned on both the FBP reconstruction and the incomplete projection data. By explicitly conditioning on the projection data in sampling the clean images, PEDB naturally incorporates data consistency. We embed the projection data into the score function of the reverse SDE. Under certain assumptions, we derive a tractable expression for the posterior score. In addition, we introduce a free parameter to control the level of stochasticity in the reverse process. We also design a discretization scheme for the reverse SDE to mitigate discretization error. Extensive experiments demonstrate that PEDB achieves strong performance in CT reconstruction from three types of incomplete data, including sparse-view, limited-angle, and truncated projections. For each of these types, PEDB outperforms evaluated state-of-the-art diffusion bridge models across standard, noisy, and domain-shift evaluations. 2025-10-26T10:00:27Z 53 pages, 7 figures, submitted to Medical Image Analysis Yuang Wang Pengfei Jin Siyeop Yoon Matthew Tivnan Shaoyang Zhang Li Zhang Quanzheng Li Zhiqiang Chen Dufan Wu http://arxiv.org/abs/2502.19146v2 Zero Echo Time Functional MRI in Humans 2025-10-25T17:18:23Z Motivation: Conventional echo planar imaging(EPI) based functional MRI(fMRI) uses the BOLD contrast to map activity changes in human brains. Introducing an efficient ZTE sequence for functional brain mapping can help address limitations of EPI and demonstrate the feasibility of using T1 related changes as a surrogate marker of brain activity. Goals: To test and optimize ZTE sequence for fMRI. Methods: A ZTE sequence with radial inside out spokes was used to prepare a dynamic imaging protocol that matches conventional EPI time course. Temporal SNR and sensitivity to susceptibility differences of ZTE were evaluated and the sequence was benchmarked against BOLD EPI in a task based visual fMRI study with healthy volunteers at 3T. Results: Phantom measurements confirmed sensitivity of the ZTE protocol to the oxygen concentration. Functional activation in primary visual cortex could be detected using ZTE. Resting state networks could also be identified using independent component analysis. Discussion: ZTE-based fMRI is proposed for mapping functional activation in human brain. ZTE is robust against susceptibility artefacts and significantly reduces acoustic noise. Radial sampling pattern allows for high undersampling rates to increase temporal resolution. 2025-02-26T14:03:17Z 20 pages, 8 figures Ali Caglar Ozen Shuai Liu Serhat Ilbey Michael Bock Uzay Emir Yen-Yu Ian Shih http://arxiv.org/abs/2510.21992v1 Cross-Section-Based Scaling Method for Material-Specific Cluster Dose Calculations -- A Proof of Concept 2025-10-24T19:55:41Z Cross-section data unavailability for non-water materials in track structure simulation software necessitates nanodosimetric quantity transformation from water to other materials. Cluster dose calculation transformation initially employed mass-density-based scaling - an approach resulting in a physically unrealistic material-independence of the cluster dose equation. This study introduces an alternative scaling method based on material-specific ionization cross-sections. The mean free path ratio of the materials for both the primary particles of the track structure simulation and for the secondary electrons served as the scaling factor. The approach was demonstrated through a cluster dose calculation for a carbon ion beam in a realistic head geometry and compared to the previous scaling method. The proposed cross-section-based scaling method resulted in a physically expected increase in cluster dose values for denser materials, which was not visible in the original scaling approach. The introduced scaling approach can be used to determine cluster dose distributions in heterogeneous geometries, a fundamental requirement for its integration into radiotherapy treatment planning frameworks. 2025-10-24T19:55:41Z Miriam Schwarze Hui Khee Looe Björn Poppe Leo Thomas Hans Rabus http://arxiv.org/abs/2510.21990v1 Technical assessment of a novel vertical CT system for upright radiotherapy simulation and treatment planning 2025-10-24T19:51:50Z Purpose: To characterize image quality, imaging dose, and dose calculation accuracy for an upright CT scanner with a six-degree-of-freedom patient positioning system. Methods: Imaging dose (CTDIvol) was measured at 120 kVp and 200 mAs. Image quality was evaluated using an ACR-464 phantom. Mean CT number accuracy was assessed within inserts of known material and uniformity as the difference in values at the center and periphery of uniform phantoms. High-contrast resolution was assessed by visible line pairs and modulation transfer function (MTF). Low-contrast performance was quantified by contrast-to-noise-ratio (CNR). Spatial integrity was evaluated between fiducials 100 mm apart. Hounsfield unit to mass density and stopping-power-ratio calibrations were performed. Proton and photon treatment plans were optimized on upright CT scans of a thorax phantom in heterogenous and homogeneous regions. Dose was forward computed on a registered recumbent CT scan and agreement evaluated using 3D gamma analysis. Results: CT imaging dose (CTDIvol) was 23.5 mGy for the 16 cm head phantom and 10.1 mGy for the 32 cm body phantom. Mean CT numbers (HU) were within the expected range for water (1.7) and acrylic (120.8). CT numbers were slightly (5-27 HU) out-of-range for air (-950.4), polyethylene (-78.8), and bone (823.0). Image uniformity was 20.2 HU and 35.0 HU for 20 cm and 48 cm diameter phantoms, respectively. Eight high-contrast line pairs were visualized. The MTF equaled 4.4 cm-1 at 50% and 7.1 cm-1 at 10%. The median CNR was 0.93, below the 1.0 tolerance. Spatial integrity was 0.36 mm. Gamma pass rates were 99.8% for photon and 90.6% for proton plans with 1%/1mm criteria, and greater than or equal to 98.0% for all plans with 3%/2mm criteria. Conclusion: Upright CT image quality and dose calculation accuracy are acceptable for photon and proton radiotherapy. 2025-10-24T19:51:50Z Jordan M. Slagowski Yuhao Yan Jessica R. Miller John W. Hayes Carson A. Hoffman Minglei Kang Carri K. Glide-Hurst http://arxiv.org/abs/2510.21362v1 Patient-specific AI for generation of 3D dosimetry imaging from two 2D-planar measurements 2025-10-24T11:46:51Z In this work we explored the use of patient specific reinforced learning to generate 3D activity maps from two 2D planar images (anterior and posterior). The solution of this problem remains unachievable using conventional methodologies and is of particular interest for dosimetry in nuclear medicine where approaches for post-therapy distribution of radiopharmaceuticals such as 177Lu-PSMA are typically done via either expensive and long 3D SPECT acquisitions or fast, yet only 2D, planar scintigraphy. Being able to generate 3D activity maps from planar scintigraphy opens the gate for new dosimetry applications removing the need for SPECT and facilitating multi-time point dosimetry studies. Our solution comprises the generation of a patient specific dataset with possible 3D uptake maps of the radiopharmaceuticals withing the anatomy of the individual followed by an AI approach (we explored both the use of 3DUnet and diffusion models) able to generate 3D activity maps from 2D planar images. We have validated our method both in simulation and real planar acquisitions. We observed enhanced results using patient specific reinforcement learning (~20% reduction on MAE and ~5% increase in SSIM) and better organ delineation and patient anatomy especially when combining diffusion models with patient specific training yielding a SSIM=0.89 compared to the ground truth for simulations and 0.73 when compared to a SPECT acquisition performed half an hour after the planar. We believe that our methodology can set a change of paradigm for nuclear medicine dosimetry allowing for 3D quantification using only planar scintigraphy without the need of expensive and time-consuming SPECT leveraging the pre-therapy information of the patients. 2025-10-24T11:46:51Z Accepted at IEEE NSS/MIC 2025 Alejandro Lopez-Montes Robert Seifert Astrid Delker Guido Boening Jiahui Wang Christoph Clement Ali Afshar-Oromieh Axel Rominger Kuangyu Shi http://arxiv.org/abs/2510.21260v1 Light-sheet microscopy to assess cancer pathology: current views and future trends 2025-10-24T08:46:55Z In recent years, light-sheet fluorescence microscopy (LSFM) has emerged as a powerful tool for visualizing and analyzing cancer tissue samples, including patient-derived specimens, organoids, biopsies, and murine models. In this work, we highlight the current applications of deep tissue LSFM in oncology and illustrate its use across a variety of human cancer tissues, including - but not limited to - prostate and breast. Here, we discuss that the potential integration of advanced LSFM technologies into clinical workflows to enable high-throughput, three-dimensional imaging of intact cancer specimens. This approach holds significant potential to enhance diagnostic precision and provide novel insights into tumour architecture and morphology. 2025-10-24T08:46:55Z 1 figure Uma Pisarović Department of Genetics & Cell Biology, Maastricht University Taichi Ochi Department of Pharmacotherapy, Epidemiology & Economics, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands, University of Groningen, Groningen, the Netherlands University Library, University of Groningen, Groningen, The Netherlands Iryna Samarska Department of Pathology, Maastricht University Medical Centre GROW Research Institute for Oncology and Reproduction, UM, Maastricht, the Netherlands Ludovico Silvestri Department of Physics, LENS - European Laboratory for Non-Linear Spectroscopy, University of Florence Thiemo J. A. van Nijnatten Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre GROW Research Institute for Oncology and Reproduction, UM, Maastricht, the Netherlands Loes F. S. Kooreman Department of Pathology, Maastricht University Medical Centre GROW Research Institute for Oncology and Reproduction, UM, Maastricht, the Netherlands Tom Marcelissen Department of Urology, Maastricht University Medical Centre Axel zur Hausen Department of Pathology, Maastricht University Medical Centre GROW Research Institute for Oncology and Reproduction, UM, Maastricht, the Netherlands Anna Schueth Department of Genetics & Cell Biology, Maastricht University GROW Research Institute for Oncology and Reproduction, UM, Maastricht, the Netherlands NUTRIM Research Institute for Nutrition and Translational Research, UM, Maastricht, the Netherlands http://arxiv.org/abs/2406.14234v2 Feed-forward active magnetic shielding 2025-10-24T08:17:43Z Magnetic fields from the brain are tiny relative to ambient fields which therefore need to be suppressed. The common solution of passive shielding is expensive, bulky and insufficiently effective, thus motivating research into the alternative of active shielding which comes in two flavours: feed-back and feed-forward. In feed-back designs (the most common), corrective fields are created by coils driven from sensors within the area that they correct, for example from the main sensors of an MEG device. In feed-forward designs (less common), corrective fields are driven from dedicated reference sensors outside the area they correct. Feed-forward can achieve better performance than feed-back, in principle, however its implementation is hobbled by an unavoidable coupling between coils and reference sensors, which reduces the effectiveness of the shielding and may affect stability, complicating the design. This paper suggests a solution that relies on a ``decoupling matrix," inserted in the signal pathway between sensors and corrective coils, to counteract the spurious coupling. This allows feed-forward shielding do reduce the ambient field to zero across the full frequency range, in principle, although performance may be limited by other factors such as current noise. The solution, which is fully data-driven and does not require geometric calculations, high-tolerance fabrication, or physical calibration, has been evaluated by simulation, but not implemented in hardware. It might contribute to the deployment of a new generation of measurement systems based on optically-pumped magnetometers (OPM). The lower cost and reduced constraints of those systems are a strong incentive to likewise reduce the cost and constraints of the shielding required to operate them, hence the appeal of active shielding. 2024-06-20T11:57:11Z 27 pages, 7 figures Alain de Cheveigné