https://arxiv.org/api/GAGNB9bnaM+vaoZM1zAdhWSiRUU2026-06-25T14:12:19Z900778015http://arxiv.org/abs/2510.27367v1Enhancing Mechanical Stimuli in Functionally Graded Bone Scaffolds Through Porosity Gradients: A Finite Element Analysis Study2025-10-31T10:56:14ZAchieving an optimal biomechanical environment within bone scaffolds is critical for promoting tissue regeneration, particularly in load-bearing anatomical sites where rigid fixation can induce stress shielding and compromise healing. Functionally graded (FG) scaffolds, which incorporate controlled variations in porosity or material properties, have attracted significant attention as a strategy to mitigate stress shielding by promoting more favourable load transfer. In this study, the effects of porosity gradient magnitude (i.e., max-to-min ratio of porosity), gradient resolution, scaffold material properties, and fixation plate rigidity on the distribution of mechanical stimuli within FG scaffolds were systematically investigated. Finite element analyses (FEA) were conducted on a femoral segmental defect model stabilised with a bone plate, and multiple porosity gradient strategies were compared against a corresponding uniform scaffold composed of body-centred cubic (BCC) unit cells. Scaffolds composed of titanium alloy (Ti-6Al-4V), bioactive glass (45S5 Bio-glass), and polylactic acid (PLA) were evaluated to capture a range of material stiffnesses. Introducing porosity gradients consistently enhanced the mean octahedral shear strain within the scaffold, particularly in regions adjacent to the fixation plate affected by stress shielding. The magnitude of mechanical stimulus improvement increased with both greater porosity gradient magnitudes and higher gradient resolution. These improvements were more pronounced in stiffer materials, such as Ti-6Al-4V, emphasising the critical interplay between scaffold material properties and architectural design. These findings highlight the importance of tailoring both porosity profiles and material selection to optimise scaffold mechanics for bone regeneration.2025-10-31T10:56:14ZAnson Wen Han CheongVahid BadaliSean KielyIman RoohaniYang JiangJianguang FangAli Entezarihttp://arxiv.org/abs/2510.27282v1Near-perfect efficiency in X-ray phase microtomography2025-10-31T08:49:59ZX-ray microtomography at synchrotron sources is fundamentally limited by the high radiation dose applied to the samples, which restricts investigations to non-native tissue states and thereby compromises the biological relevance of the resulting data. The limitation stems from inefficient indirect detection schemes that require prolonged exposures. Efforts to extract additional contrast through multimodal techniques, like modulation-based imaging, worsen the problem by requiring multiple tomographic scans. In addition, the techniques suffer from low modulator pattern visibility, which reduces measurement efficiency and sensitivity. We address both the detection efficiency and modulation visibility challenges using a novel setup that combines an X-ray waveguide, a structured phase modulator, and a photon-counting detector. Our approach simultaneously achieves near-theoretical limits in both visibility (95%) and quantum efficiency (98%), thereby enabling dose-efficient multimodal microtomography at single-micrometer resolution. This advance will enable new classes of experiments on native-state biological specimens with the potential to advance biomedical research, disease diagnostics, and our understanding of tissue structure in physiological environments.2025-10-31T08:49:59ZDominik JohnGregor BreitenhuberSami WirtensohnFranziska HinterdoblerLuka GaetaniSara SavatovićJens LuchtMarkus OsterhoffMarina EckermannTim SaldittJulia Herzen10.1364/OPTICA.584432http://arxiv.org/abs/2510.26928v1Ultra-High Dose-Rates, the FLASH Effect, and Hydrogen Peroxide Yields: Do Experiments and Simulations Really Disagree?2025-10-30T18:36:41ZRadiation chemistry of model systems irradiated with ultra-high dose-rates (UHDR) is key to obtain a mechanistic understanding of the sparing of healthy tissue, which is called the FLASH effect. It is envisioned to be used for efficient treatment of cancer by FLASH radiotherapy. However, it seems that even the most simple model systems, water irradiated with varying dose-rates (DR), pose a challenge. This became evident, as differences within measured and predicted hydrogen peroxide (H2O2) yields (g-values) for exposure of liquid samples to conventional DR and UHDR were reported. Many of the recently reported values contradict older experiments and current Monte-Carlo simulations(MCS). In the present work, we aim to identify possible reasons of these discrepancies and propose ways to overcome this issue. Hereby a short review of recent and classical literature concerning experimental and simulational studies is performed. The studies cover different radiation sources, from gamma rays, high-energy electrons, heavy particles (protons and ions) with low and high linear energy transfer (LET), and samples of hypoxic & oxygenated water, with cosolutes such as bovine-serum albumine (BSA). Results are for additional experimental parameters, such as solvent, sample container and analysis methods used to determine the respective g-values of H2O2. Similarly the parameter of the MCS by the step-by-step approach, or the independent-reaction time (IRT) method are discussed. Here, UHDR induced modification of the radical-radical interaction and dynamics, not governed by diffusion processes, may cause problems. Approaches to test these different models are highlighted to allow progress: by making the step from a purely descriptive discourse of the effects observed, towards testable models, which should clarify the reasons of how and why such a disagreement came to light in the first place.2025-10-30T18:36:41Z16 pagesMarc Benjamin Hahnhttp://arxiv.org/abs/2510.26903v1PF-DAformer: Proximal Femur Segmentation via Domain Adaptive Transformer for Dual-Center QCT2025-10-30T18:07:56ZQuantitative computed tomography (QCT) plays a crucial role in assessing bone strength and fracture risk by enabling volumetric analysis of bone density distribution in the proximal femur. However, deploying automated segmentation models in practice remains difficult because deep networks trained on one dataset often fail when applied to another. This failure stems from domain shift, where scanners, reconstruction settings, and patient demographics vary across institutions, leading to unstable predictions and unreliable quantitative metrics. Overcoming this barrier is essential for multi-center osteoporosis research and for ensuring that radiomics and structural finite element analysis results remain reproducible across sites. In this work, we developed a domain-adaptive transformer segmentation framework tailored for multi-institutional QCT. Our model is trained and validated on one of the largest hip fracture related research cohorts to date, comprising 1,024 QCT images scans from Tulane University and 384 scans from Rochester, Minnesota for proximal femur segmentation. To address domain shift, we integrate two complementary strategies within a 3D TransUNet backbone: adversarial alignment via Gradient Reversal Layer (GRL), which discourages the network from encoding site-specific cues, and statistical alignment via Maximum Mean Discrepancy (MMD), which explicitly reduces distributional mismatches between institutions. This dual mechanism balances invariance and fine-grained alignment, enabling scanner-agnostic feature learning while preserving anatomical detail.2025-10-30T18:07:56Z22 Pages, 5 Tables, 10 Figures. The combination of GRL and MMD achieved the most balanced performance, reducing contour deviations and enhancing surface smoothnessRochak DhakalChen ZhaoZixin ShiJoyce H. KeyakTadashi S. KanekoKuan-Jui SuHui ShenHong-Wen DengWeihua Zhouhttp://arxiv.org/abs/2510.26668v1Zoeppritz equations: from seismology to medical exploration2025-10-30T16:37:32ZMore than a century ago, Karl Bernhard Zoeppritz derived the equations that determine the reflected and transmitted coefficients at a planar interface for an incident seismic wave. The coefficients so obtained are a function of the elastic parameters of the media on each side of the interface and the angle of incidence. Approximations of the equations have been proposed and used in geophysical exploration, however, full use of the equations and their generalization to multiple layers could offer richer information about the properties of the media and be helpful in medical diagnosis via ultrasound. In this work, we investigate how to extract information from the angle-dependent reflection coefficients, including critical angles and the wave distortion at the interface between two and three media. It is shown that it is possible to separate the effect of density from speed of sound mismatch by measuring amplitudes as a function of angle of incidence (AVA). And examining the critical angle and waveform distortion of the reflected waves can reveal the thickness of an intermediate layer, even with subwavelength resolution. These studies could be integrated into medical imaging and also into the training of artificial intelligence systems that assist in diagnosis. In particular, they could help prevent cerebrovascular accidents by early detection of the formation and hardening of plaque in the arteries that irrigate the brain.2025-10-30T16:37:32ZHarry G. SaavedraRamiro Moro10.33017/RevECIPeru2025.0008/http://arxiv.org/abs/2510.26563v1Fraction-variant VMAT planning for patients with complex gynecological and head-and-neck cancer2025-10-30T14:53:19ZBackground and Purpose: Increasing the number of arcs in volumetric modulated arc therapy (VMAT) allows for better intensity modulation and may improve plan quality. However, this leads to longer delivery times, which may cause patient discomfort and increase intra-fractional motion. In this study, it was investigated whether the delivery of different VMAT plans in different fractions may improve the dosimetric quality and delivery efficiency for the treatment of patients with complex tumor geometries.
Materials and Methods: A direct aperture optimization algorithm was developed which allows for the simultaneous optimization of different VMAT plans to be delivered in different fractions, based on their cumulative physical dose. Each VMAT plan is constrained to deliver a uniform dose within the target volume, such that the entire treatment does not alter the fractionation scheme and is robust against inter-fractional setup errors. This approach was evaluated in-silico for ten patients with gynecological and head-and-neck cancer.
Results: For all patients, fraction-variant treatments achieved better target coverage and reduced the dose to critical organs-at-risk compared to fraction-invariant treatments that deliver the same plan in every fraction, where the dosimetric benefit was shown to increase with the number of different plans to be delivered. In addition, 1-arc and 2-arc fraction-variant treatments could approximate the dosimetric quality of 3-arc fraction-invariant treatments, while reducing the delivery time from 180 s to 60 s and 120 s, respectively.
Conclusions: Fraction-variant VMAT treatments may achieve excellent dosimetric quality for patients with complex tumor geometries, while keeping the delivery time per fraction viable.2025-10-30T14:53:19ZNathan TorelliMadalyne DayJan Unkelbachhttp://arxiv.org/abs/2510.26388v1Monitoring Head Movement in a Brain PET Scanner2025-10-30T11:32:09ZWhen acquiring PET images, body motions are unavoidable, given that the acquisition time could last 10-20 minutes or more. These motions can seriously deteriorate the quality of the final image at the level of image reconstruction and attenuation corrections. Movements can have rhythmic patterns, related to respiratory or cardiac motions, or they can be abrupt reflexive actions caused by the patient's discomfort. Many approaches, software and hardware, have been developed to mitigate this problem where each approach has its own advantages and disadvantages. In this work we present a simulation study of a head monitoring device, named CrowN@22, intended to be used in conjunction with a dedicated brain PET scanner. The CrowN@22 device consists of six point sources of non-pure positron emitter isotopes, such as 22Na or 44Sc, mounted in crown-like rings around the head of the patient. The relative positions of the point sources are predefined and their actual position, once mounted, can be reconstructed by tagging the extra 1274 keV photon (in the case of 22Na). These two factors contribute to a superb signal-to-noise ratio, distinguishing between the signal from the 22Na monitor point sources and the background signal from the FDG in the brain. Hence, even with a low activity for the monitor point sources, as low as 10 kBq per point source, in the presence of 75 MBq activity of 18F in the brain, one can detect brain movements with a precision of less than 0.3 degrees, or 0.5 mm, which is of the order of the PET spatial resolution, at a sampling rate of 1 Hz.2025-10-30T11:32:09Z17 pages, 9 figuresMachiel KolsteinMokhtar ChmeissaniAndreu Pachecohttp://arxiv.org/abs/2510.26377v1Microwave Cytometry with Machine Learning for Shape-Resolved Microplastic Detection2025-10-30T11:17:47ZMicroplastics are increasingly recognized as a global environmental health threat, yet their detection and characterization remain constrained by the cost, form factor, and throughput of existing analytical tools. Portable micro/nanotechnology-based sensors are emerging to address this need, but most rely on the assumption of spherical particle geometry in their operating principle, limiting their relevance for environmental analysis. Here, we overcome this limitation by advancing microwave cytometry with machine learning-enabled shape recognition. Microwave cytometry is a flow-through electronic platform that integrates microwave resonator responses with low-frequency impedance signals to capture the dielectric signatures of individual particles. Using microscopy-derived shape measurements as ground truth, we trained a random forest model to decode these information-rich waveforms. Once trained, the system operates without optical input, enabling electronic-only determination of particle geometry. We demonstrate extraction of the major and minor axes of ellipsoidal microparticles with <8% relative error on average and use these predictions to derive the dielectric permittivity of ellipsoid particles. This approach removes long-standing shape assumptions in microplastic sensing and establishes a pathway toward portable, high-throughput, morphology-aware detection technologies.2025-10-30T11:17:47ZSayedus SalehinSyed Shaheer Uddin AhmedUzay TefekLaura WeirauchM. Selim Hanayhttp://arxiv.org/abs/2510.26272v1Simultaneous optimization of non-coplanar beam orientations and cumulative EQD2 distribution for high-dose reirradiation of locoregionally recurrent non-small cell lung cancer2025-10-30T08:56:29ZBackground and Purpose: Reirradiation for non-small cell lung cancer (NSCLC) is commonly delivered using coplanar techniques. In this study, we developed a beam orientation optimization algorithm for reirradiation planning to investigate whether the selection of favorable non-coplanar beam orientations may limit cumulative doses to critical organs-at-risk (OARs) and thus improve the therapeutic window.
Materials and Methods: Fifteen cases of challenging high-dose reirradiation for locoregionally recurrent NSCLC were included in this in-silico study. For each patient, the dose distribution from the previous treatment was first mapped to the reirradiation planning CT using rigid dose registration, and subsequently converted to equivalent dose in 2 Gy fractions (EQD2). A 2-arc non-coplanar reirradiation plan, combining dynamic gantry and couch rotation, was then generated using an EQD2-based direct aperture optimization algorithm, which allows for the simultaneous optimization of the dynamic gantry-couch path and the cumulative EQD2 distribution. Non-coplanar reirradiation plans were benchmarked against 2-arc coplanar VMAT plans, which mimic state-of-the-art practice for reirradiation of NSCLC.
Results: Non-coplanar reirradiation plans could reduce the maximum cumulative EQD2 to critical OARs such as bronchial tree, esophagus, thoracic wall and trachea by at least 5 Gy2 for 6 out of 15 patients compared to coplanar reirradiation plans. At the same time, target coverage and lung EQD2 metrics were comparable for both methods.
Conclusions: The automated selection of favorable non-coplanar beam orientations may reduce the maximum cumulative EQD2 to critical OARs in challenging thoracic reirradiation cases. This allows to explore either better OAR sparing or dose-escalation in future clinical studies.2025-10-30T08:56:29ZNathan TorelliJonas WillmannKatja DaehlerMadalyne DayNicolaus AndratschkeJan Unkelbachhttp://arxiv.org/abs/2510.25944v1Development and pilot evaluation of a virtual reality simulator for HDR prostate brachytherapy2025-10-29T20:40:14ZPurpose: To develop a virtual reality simulator for high dose rate prostate brachytherapy and to test whether participation is associated with immediate gains in self-reported confidence across predefined procedural domains in two cohorts. Methods: Two modules were developed and implemented using Unreal Engine: patient preparation and template guided needle insertion. Oncology staff and trainees completed pre and post surveys that assessed confidence for recalling steps, explaining steps, identifying equipment, and explaining equipment function. Studies were conducted at the Hands On Brachytherapy Workshop (HOWBT) in London, Ontario, and at Sunnybrook Odette Cancer Centre in Toronto, Ontario. Paired Wilcoxon signed rank tests with two-sided p values compared before and after scores within each module. Results: Patient preparation (N=11) confidence increased for recalling steps (W=65, p=0.002), explaining steps (W=51, p = 0.023), identifying equipment (W=65, p=0.002), and explaining equipment function (W=60, p=0.0078). Needle insertion (N=27) confidence increased for recalling steps (W=292, p<0.001), explaining steps (W=347, p<0.001), identifying equipment (W=355, p<0.001), and explaining equipment function (W=354, p<0.001). Conclusion: The simulator was feasible to deploy and was associated with higher self-reported confidence across key domains immediately after training. Findings may inform future curriculum design and implementation work.2025-10-29T20:40:14Z15 pagesAnton VarlukhinToronto Metropolitan University, Toronto, CanadaMackenzie SmithSunnybrook Health Sciences Center, Toronto, CanadaFahad AlamDepartment of Anesthesiology, Temerty Medicine, University of Toronto, Toronto, CanadaAmandeep TaggerSunnybrook Health Sciences Center, Toronto, CanadaDepartment of Radiation Oncology, Temerty Medicine, University of Toronto, Toronto, CanadaGerard MortonSunnybrook Health Sciences Center, Toronto, CanadaDepartment of Radiation Oncology, Temerty Medicine, University of Toronto, Toronto, CanadaMoti PaudelSunnybrook Health Sciences Center, Toronto, CanadaDepartment of Radiation Oncology, Temerty Medicine, University of Toronto, Toronto, CanadaAndrew LoblawSunnybrook Health Sciences Center, Toronto, CanadaDepartment of Radiation Oncology, Temerty Medicine, University of Toronto, Toronto, CanadaLucas MendezVerspeeten Family Cancer Center, London Health Sciences Center, London, CanadaDepartment of Radiation Oncology, Western University, London, CanadaDouglas HooverVerspeeten Family Cancer Center, London Health Sciences Center, London, CanadaDepartment of Radiation Oncology, Western University, London, CanadaRaffi KarshafianToronto Metropolitan University, Toronto, CanadaHumza NusratHenry Ford Health, Detroit, USADepartment of Radiation Oncology, Michigan State University, East Lansing, USAToronto Metropolitan University, Toronto, Canadahttp://arxiv.org/abs/2510.22903v3Radiation enhanced diffusion in cartilages as a physical mechanism underlying radiation treatments of osteoarthritis and related disorders2025-10-29T11:27:05ZDegradation of joint cartilages can result in osteoarthritis (OA) affecting about 10\% of the US population and responsible for significant hospitalization costs. While observations show that low dose radiation treatments (LDRT) bring improvements for a majority of OA patients, the underlying mechanism is not sufficiently understood. Here, we show how the radiation enhanced diffusion (RED) can boost the molecular transport in cartilages promoting cartilage self-healing rendering a mechanism for the observed positive LDRT effects on OA. Along with quantitative estimates for RED, we predict a related phenomenon of the electric charge build up that allows LDRT schedules promoting desirable types of molecular transports dominated by either positive or negative molecular species. Our analyses call upon further experimental verifications and clinical trials with curative rather than palliative intent. In addition to OA applications, our developed approaches can be useful for sports medicine dealing with damage or degeneration of the articular cartilages.2025-10-27T01:18:36Z9 pages, 3 figuresDiana ShvydkaVictor Karpovhttp://arxiv.org/abs/2510.25256v1Photoacoustics on the go: An Embedded Photoacoustic Sensing Platform2025-10-29T08:11:48ZSeveral centimeters below the skin lie multiple biomarkers, such as glucose, oxygenation, and blood flow. Monitoring these biomarkers regularly and in a non-invasive manner would enable early insight into metabolic status and vascular health. Currently, there are only a handful of non-invasive monitoring systems. Optical methods offer molecular specificity (i.e., multi-biomarker monitoring) but have shallow reach (a few millimeters); ultrasound penetrates deeper but lacks specificity; and MRI is large, slow, and costly. Photoacoustic (PA) sensing combines the best of optical and ultrasound methods. A laser transmitter emits pulses that are absorbed by different molecules, providing specificity. These light pulses generate pressure changes that are captured by an ultrasound receiver, providing depth. Photoacoustic sensing is promising, but the current platforms are bulky, complex, and costly. We propose the first embedded PA platform. Our contributions are fourfold. First, inspired by LiDAR technology, we propose a novel transmitter that emits pulses similar to those in the state-of-the-art (SoA), but instead of using high-voltage sources and complex electronic interfaces, we use a simple low-power microcontroller (MCU). Second, we carry out a thorough analysis of our custom transmitter and a commercial system. Third, we build a basic ultrasound receiver that is able to process the faint signal generated by our transmitter. Lastly, we compare the performance of our platform against a SoA commercial system, and show that we can detect glucose and (de)oxygenated hemoglobin in two controlled solution studies. The resulting signal characteristics indicate a plausible path toward noninvasive, real-time, at-home sensing relevant to diabetes care. More broadly, this platform lays the groundwork for translating the promise of PA sensing into a broader practical reality.2025-10-29T08:11:48ZTalia XuCaitlin SmithCharles LoJami ShepherdGijs van SoestMarco Zunigahttp://arxiv.org/abs/2510.24703v1Cluster Dose Prediction in Carbon Ion Therapy: Using Transfer Learning from a Pretrained Dose Prediction U-Net2025-10-28T17:54:04ZThe cluster dose concept offers an alternative to the radiobiological effectiveness (RBE)-based model for describing radiation-induced biological effects. This study examines the application of a neural network to predict cluster dose distributions, with the goal of replacing the computationally intensive simulations currently required. Cluster dose distributions are predicted using a U-Net that was initially pretrained on conventional dose distributions. Using transfer learning techniques, the decoder path is adapted for cluster dose estimation. Both the training and pretraining datasets include head and neck regions from multiple patients and carbon ion beams of varying energies and positions. Monte Carlo (MC) simulations were used to generate the ground truth cluster dose distributions. The U-Net enables cluster dose estimation for a single pencil beam within milliseconds using a graphics processing unit (GPU). The predicted cluster dose distributions deviate from the ground truth by less than 0.35%. This proof-of-principle study demonstrates the feasibility of accurately estimating cluster doses within clinically acceptable computation times using machine learning (ML). By leveraging a pretrained neural network and applying transfer learning techniques, the approach significantly reduces the need for large-scale, computationally expensive training data.2025-10-28T17:54:04ZMiriam SchwarzeHui Khee LooeBjörn PoppeLeo ThomasHans Rabushttp://arxiv.org/abs/2510.24154v1A GPU-based Monte Carlo framework for IMRT QA using EPID transit dosimetry2025-10-28T07:47:24ZPurpose: We presented a GPU-based MC framework, ARCHER-EPID, specifically designed for EPID transit dosimetry, with improving accuracy and efficiency. Methods: A comprehensive MC framework was developed to perform full radiation transport simulations through three distinct zones: a detailed linear accelerator head model, a CT-based patient/phantom geometry, and a realistic, multi-layered EPID model. To convert the simulated absorbed dose to a realistic detector signal, a dose-response correction model was implemented. The framework was validated by comparing simulations against experimental measurements for 25 IMRT fields delivered to both a solid water phantom and a anthropomorphic phantom. Agreement was quantified using Gamma analysis. Results: The GPU-accelerated ARCHER-EPID framework can complete the simulation for a complex IMRT field in about 90 seconds. A 2D correction factor lookup table is generated by parameterizing radiological thickness and effective field size to account for the EPID's energy-dependent response. The data revealed that for small fields, beam hardening is the dominant effect, while for large fields, the contribution from patient-generated scatter overwhelms this effect. The average 2D gamma passing rates (3%/3 mm criteria) between simulation and measurements are 98.43% for the solid water phantom and 97.86% for the anthropomorphic phantom, respectively. Visual comparison of the images and dose profiles between simulation and measurements show a high degree of agreement. Conclusions: We have successfully developed and validated a GPU-based MC framework that provides gold-standard accuracy for EPID transit dosimetry in radiotherapy. The results demonstrate that our proposed method has potential for routine application in PSQA.2025-10-28T07:47:24ZNing GaoDidi LiNa LiuYankui ChangQiang RenXi PeiZhi WangXie George Xuhttp://arxiv.org/abs/2509.09755v2An Overview of Physiologically Based Pharmacokinetic (PBPK) and Population Pharmacokinetic (PopPK) Models2025-10-27T23:17:03ZThis review discusses the current applications, advantages, and limitations of PBPK and PopPK models in radiopharmaceutical therapy (RPT). PBPK models simulate radiopharmaceutical kinetics by integrating prior physiological and drug parameter information, whereas PopPK models leverage population data to enhance individual dose estimation accuracy. Future directions include developing hybrid models, incorporating artificial intelligence, and establishing regulatory guidelines to promote their clinical adoption. Ultimately, these modeling strategies aim to enable precise, personalized RPT dosing, thereby improving therapeutic outcomes and safety.2025-09-11T17:07:38ZDeni HardiansyahBisma Baron PatrianeshaKuangyu ShiBabak SabouryArman RahmimGerhard Glatting