https://arxiv.org/api/EXWYQMkTyfZ9KIvhaRl+THctk1k2026-06-24T11:43:20Z900176515http://arxiv.org/abs/2511.00978v1Multiplexed Catheter-Integrated Pressure Sensing System for Endoluminal Interventions2025-11-02T15:42:31ZAdvances in flexible catheters pave the way for minimally invasive diagnosis and treatment of luminal organs and tubular structures through endoluminal interventions. A key challenge is in establishing non-constraining pressure monitoring at the interfaces between medical catheters and intraluminal anatomy exhibiting curvilinear contours, structural variability, and time-dependent physiological motion. This work presents a scalable and multi-purpose pressure sensing system for multidirectional monitoring of tissue interactions, establishing a robust solution for deploying diagnostic and therapeutic instruments in various types of endoluminal interventions. This approach provides an integrated system encompassing pressure sensors, catheters, and signal acquisition devices. A poly (vinylidene fluoride-co-trifluoroethylene) (P(VDF-TrFE)) film is miniaturized and configured into a multiplexed piezoelectric-based pressure sensor, providing flexibility and scalability in conforming to medical catheters with curved surfaces. The catheter is fabricated with a cost-effective and highly scalable fiber drawing technology, establishing a means of fast prototyping catheters with bespoke structures for sensor integration and medical instrument integration. The system achieves enhanced pressure detection sensitivity and a comparable sensing range, compared with state-of-the-art catheter-integrated sensors. Through in-vitro phantom studies, the system performs precise multi-directional sensing within various clinical endoluminal scenarios, showing its potential in digitalizing tissue interactions during endoluminal interventions.2025-11-02T15:42:31ZXiaotong GuoQindong ZhengJinshi ZhaoBing LiEric Morgan Yeatmanhttp://arxiv.org/abs/2511.00745v1High-Power Dual-Channel Field Chamber for High-Frequency Magnetic Neuromodulation2025-11-02T00:04:54ZSeveral novel methods, including magnetogenetics and magnetoelectric stimulation, use high frequency alternating magnetic fields to precisely manipulate neural activity. To quantify the behavioral effects of such interventions in a freely moving mouse, we developed a dual-channel magnetic chamber, specifically designed for rate-sensitive magnetothermal-genetic stimulation, and adaptable for other uses of alternating magnetic fields. Through an optimized coil design, the system allows independent control of two spatially orthogonal uniform magnetic fields delivered at different frequencies within a 10 cm x 10 cm x 6 cm chamber. The two channels have nominal frequencies of 50 and 550 kHz with peak magnetic field strengths of 88 and 12.5 mT, achieved with resonant coil drives having peak voltages of 1.6 and 1.8 kV and currents of 1.0 and 0.26 kA, respectively. Additionally, a liquid cooling system enables magnetic field generation for second-level duration, and an observation port and camera allow video capture of the animal's behavior within the chamber. The system generates high-amplitude magnetic fields across two widely separated frequency channels with negligible interference (< 1%). Relatively uniform magnetic field distribution (+/-10% across 94% of the chamber volume) is maintained throughout the chamber, and temperature increase of the inner side of the coil enclosure during the operation is limited to < 0.35 °C/s to ensure in vivo safety. Using cobalt-doped and undoped iron oxide nanoparticles, we demonstrate channel-specific heating rates of 3.5 °C/s and 1.5 °C/s, respectively, validating frequency-selectivity. Both channels can run continuously for four seconds stably.2025-11-02T00:04:54Z25 pages, 8 figuresXiaoyang TianHui WangBoshuo WangJinshui ZhangDong YanJeannette IngabireSamantha CofflerGuillaume DuretQuoc-Khanh PhamGang BaoJacob T. RobinsonStefan M. GoetzAngel V. Peterchevhttp://arxiv.org/abs/2511.00744v1Magnetic Materials for Transcranial Magnetic Stimulation (TMS)2025-11-02T00:03:49ZVarious coils for transcranial magnetic stimulation (TMS) are widely available for clinical and research use. These coils are almost all designed as air coils, which require large levels of energy to achieve a given magnetic flux density and in turn electric field strength, whereas in other sectors, such as power electronics or electrical machines, magnetic materials have been used for a long time to achieve higher efficiencies. We tested the impact on the electric and magnetic properties of different soft magnetic materials, including various ferrite cores, laminated sheet materials of nonisotropic corn-oriented silicon-steel, non-oriented silicon-steel, as well as cobalt-iron, and soft magnetic compound powder cores with insulated particles. Every material led to a reduction in coil current and voltage for the same target electric field strength. For the same field energy, every material yielded lower losses. Most common materials saturated already at very low currents. More material in thicker layers could shift the saturation point but at the cost of high weight. Due to their low saturation flux density, ferrites appear unsuitable for the high amplitude requirements of TMS. Laminated sheet materials and powder cores reduce the pulse energy, but the laminated sheet material adds more weight for the same effect than powder cores. Thus, appropriate magnetic materials can reduce the required pulse energy. Saturation flux density is the most relevant parameter, whereas the permeability beyond a certain base level is practically irrelevant. Most importantly, the weight of a magnetic-core coil may always be increased compared to an air coil for the same target field.2025-11-02T00:03:49Z30 pages, 14 figures, 2 tablesMax KoehlerAkshata SangleStefan M. Goetzhttp://arxiv.org/abs/2511.00563v1Active learning-based variance reduction for Monte Carlo simulations: A feasibility study for the nanodosimetry around a gold nanoparticle2025-11-01T13:58:02ZObjective: This work presents a data-driven importance sampling-based variance reduction (VR) scheme inspired by active learning. The method is applied to the estimation of an optimal impact-parameter distribution in the calculation of ionization clusters around a gold nanoparticle (NP). Here, such an optimal importance distribution can not be inferred from principle. Approach: An iterative optimization procedure is set up that uses a Gaussian Process Sampler to propose optimal sampling distributions based on a loss function. The loss is constructed based on appropriate heuristics. The optimization code obtains estimates of the number of ionization clusters in shells around the NP by interfacing with a Geant4 simulation via a dedicated Transmission Control Protocol (TCP) interface. Main results: It is shown that the so-derived impact-parameter distribution easily outperforms the actual, uniform irradiation case. The results resemble those obtained with other VR schemes but do still slightly overestimate background contributions. Significance: While the method presented is a proof-of-principle, it provides a novel method of estimating importance distributions in ill-posed scenarios. The presented TCP interface described here is a simple and efficient method to expose compiled Geant4 code to other scripts, written for example, in Python.2025-11-01T13:58:02Z21 pages, 8 figures, submitted to Physica Scripta (IOP Publishing)Leo ThomasMiriam SchwarzeHans Rabushttp://arxiv.org/abs/2511.00331v1Treat-through OLED Displays: Dosimetry and performance of OLED AVATAR screens for Megavoltage Radiotherapy2025-11-01T00:18:02ZThe AVATAR system utilizes a radiolucent video display to help relax and immobilize pediatric patients during radiotherapy. This study investigates the use of OLED (Organic Light Emitting Diode) displays, which offer superior image quality and faster alignment compared to traditional projector-based systems, albeit with slightly increased thickness. The dose perturbations caused by these screens were assessed to evaluate their suitability for radiotherapy.
A 20 cm OLED screen was positioned in the patient's line of sight, between the patient's head and the radiation source. The screen comprises a 0.25 mm thick flexible OLED panel and a custom carbon fiber backing (0.3 to 0.6 mm thick), with most electronic components relocated via ribbon cable. 6 MV portal images were captured with and without the screen to create transmission maps. Additionally, parallel plate ion chamber measurements were taken at the surface and at depth in a solid water phantom. The OLED's radiation tolerance was tested with a 100 Gy dose delivery and 12 months of use in an active radiotherapy linac vault.
The portal image transmission maps indicated an average attenuation difference of 0.3\% (SD = 0.37 \%) between measurements with and without the AVATAR screen, with a maximum point attenuation of 3\%. Ion chamber measurements revealed a 0.31\% decrease in dose at 2 cm depth and a 7.04 \% increase at the surface under an anterior-posterior beam. For a VMAT arc, the dose difference was 0.04 \% at 2 cm depth and 0.1\% at the phantom surface.
The minimal dose deviations indicate that these screens are suitable for megavoltage arc therapy without significantly affecting the target dose. While surface dose is slightly increased for static anterior beams, it remains low. For lower photon energies or particle beams, larger perturbations may occur, necessitating further measurements or beam entry avoidance.2025-11-01T00:18:02ZDaniyal S KhanAaron GarzaJoseph B SchulzBilly W LooSusan M Hiniker Clinton GibsonLawrie B Skinnerhttp://arxiv.org/abs/2511.00304v1Variational Percolation Bounds for Cellular Membrane Occlusion2025-10-31T22:59:39ZMalignant membranes cluster nutrient transporters within glycan-rich domains, sustaining metabolism through redundant intake routes. A theoretical framework links interfacial chemistry to transport suppression and energetic or redox collapse. The model unites a screened Poisson-Nernst-Planck electrodiffusion problem, an interfacial potential of mean force, and a reduced energetic-redox module connecting flux to ATP/NADPH balance. From this structure, capacitary-spectral bounds relate total flux to the inverse principal eigenvalue (J_tot <= C*exp(-beta*chi_eff)*P(theta)). Two near-orthogonal levers, geometry and field strength, govern a linear suppression regime below a percolation-type knee, beyond which conductance collapses. A composite intake index Xi = w_G*J_GLUT + w_A*J_LAT/ASCT + w_L*J_MCT dictates energetic trajectories: once below a maintenance threshold, ATP and NADPH fall jointly and redox imbalance drives irreversible commitment. Normal membranes, with fewer transport mouths and weaker fields, remain above this threshold, defining a natural selectivity window. The framework demonstrates existence, regularity, and spectral monotonicity for the self-adjoint PNP operator, establishing a geometric-spectral transition that links molecular parameters such as branching and sulfonation to measurable macroscopic outcomes with predictive precision.2025-10-31T22:59:39ZCesar MelloFernando Medina da Cunhahttp://arxiv.org/abs/2511.00301v1A systematic evaluation of uncertainty quantification techniques in deep learning: a case study in photoplethysmography signal analysis2025-10-31T22:54:13ZIn principle, deep learning models trained on medical time-series, including wearable photoplethysmography (PPG) sensor data, can provide a means to continuously monitor physiological parameters outside of clinical settings. However, there is considerable risk of poor performance when deployed in practical measurement scenarios leading to negative patient outcomes. Reliable uncertainties accompanying predictions can provide guidance to clinicians in their interpretation of the trustworthiness of model outputs. It is therefore of interest to compare the effectiveness of different approaches. Here we implement an unprecedented set of eight uncertainty quantification (UQ) techniques to models trained on two clinically relevant prediction tasks: Atrial Fibrillation (AF) detection (classification), and two variants of blood pressure regression. We formulate a comprehensive evaluation procedure to enable a rigorous comparison of these approaches. We observe a complex picture of uncertainty reliability across the different techniques, where the most optimal for a given task depends on the chosen expression of uncertainty, evaluation metric, and scale of reliability assessed. We find that assessing local calibration and adaptivity provides practically relevant insights about model behaviour that otherwise cannot be acquired using more commonly implemented global reliability metrics. We emphasise that criteria for evaluating UQ techniques should cater to the model's practical use case, where the use of a small number of measurements per patient places a premium on achieving small-scale reliability for the chosen expression of uncertainty, while preserving as much predictive performance as possible.2025-10-31T22:54:13ZCiaran BenchOskar PfefferVivek DesaiMohammad MoulaeifardLoïc CoquelinPeter H. CharltonNils StrodthoffNando HegemannPhilip J. AstonAndrew Thompsonhttp://arxiv.org/abs/2510.27679v1Dark-Field X-Ray Imaging Significantly Improves Deep-Learning based Detection of Synthetic Early-Stage Lung Tumors in Preclinical Models2025-10-31T17:47:40ZLow-dose computed tomography (LDCT) is the current standard for lung cancer screening, yet its adoption and accessibility remain limited. Many regions lack LDCT infrastructure, and even among those screened, early-stage cancer detection often yield false positives, as shown in the National Lung Screening Trial (NLST) with a sensitivity of 93.8 percent and a false-positive rate of 26.6 percent. We aim to investigate whether X-ray dark-field imaging (DFI) radiograph, a technique sensitive to small-angle scatter from alveolar microstructure and less susceptible to organ shadowing, can significantly improve early-stage lung tumor detection when coupled with deep-learning segmentation. Using paired attenuation (ATTN) and DFI radiograph images of euthanized mouse lungs, we generated realistic synthetic tumors with irregular boundaries and intensity profiles consistent with physical lung contrast. A U-Net segmentation network was trained on small patches using either ATTN, DFI, or a combination of ATTN and DFI channels. Results show that the DFI-only model achieved a true-positive detection rate of 83.7 percent, compared with 51 percent for ATTN-only, while maintaining comparable specificity (90.5 versus 92.9 percent). The combined ATTN and DFI input achieved 79.6 percent sensitivity and 97.6 percent specificity. In conclusion, DFI substantially improves early-tumor detectability in comparison to standard attenuation radiography and shows potential as an accessible, low-cost, low-dose alternative for pre-clinical or limited-resource screening where LDCT is unavailable.2025-10-31T17:47:40ZJoyoni DeyHunter C. MeyerMurtuza S. Taqihttp://arxiv.org/abs/2408.12921v3Spatially Regularized Super-Resolved Constrained Spherical Deconvolution (SR$^2$-CSD) of Diffusion MRI Data2025-10-31T11:13:25ZConstrained Spherical Deconvolution (CSD) is widely used to estimate the white matter fiber orientation distribution (FOD) from diffusion MRI data. Its angular resolution depends on the maximum spherical harmonic order ($l_{max}$): low $l_{max}$ yields smooth but poorly resolved FODs, while high $l_{max}$, as in Super-CSD, enables resolving fiber crossings with small inter-fiber angles but increases sensitivity to noise. In this proof-of-concept study, we introduce Spatially Regularized Super-Resolved CSD (SR$^2$-CSD), a novel method that regularizes Super-CSD using a spatial FOD prior estimated via a self-calibrated total variation denoiser. We evaluated SR$^2$-CSD against CSD and Super-CSD across four datasets: (i) the HARDI-2013 challenge numerical phantom, assessing angular and peak number errors across multiple signal-to-noise ratio (SNR) levels and CSD variants (single-/multi-shell, single-/multi-tissue); (ii) the Sherbrooke in vivo dataset, evaluating spatial coherence of FODs; (iii) a six-subject test-retest dataset acquired with both full (96 gradient directions) and subsampled (45 directions) protocols, assessing reproducibility; and (iv) the DiSCo phantom, evaluating tractography accuracy under varying SNR levels and multiple noise repetitions. Across all evaluations, SR$^2$-CSD consistently reduced angular and peak number errors, improved spatial coherence, enhanced test-retest reproducibility, and yielded connectivity matrices more strongly correlated with ground-truth. Most improvements were statistically significant under multiple-comparison correction. These results demonstrate that incorporating spatial priors into CSD is feasible, mitigates estimation instability, and improves FOD reconstruction accuracy.2024-08-23T08:54:15Z21 pages, 9 figures; Supplementary Material appended after the ReferencesEkin TaskinGabriel GirardJuan Luis Villarreal HaroJonathan Rafael-PatiñoEleftherios GaryfallidisJean-Philippe ThiranErick Jorge Canales-Rodríguezhttp://arxiv.org/abs/2510.27367v1Enhancing Mechanical Stimuli in Functionally Graded Bone Scaffolds Through Porosity Gradients: A Finite Element Analysis Study2025-10-31T10:56:14ZAchieving an optimal biomechanical environment within bone scaffolds is critical for promoting tissue regeneration, particularly in load-bearing anatomical sites where rigid fixation can induce stress shielding and compromise healing. Functionally graded (FG) scaffolds, which incorporate controlled variations in porosity or material properties, have attracted significant attention as a strategy to mitigate stress shielding by promoting more favourable load transfer. In this study, the effects of porosity gradient magnitude (i.e., max-to-min ratio of porosity), gradient resolution, scaffold material properties, and fixation plate rigidity on the distribution of mechanical stimuli within FG scaffolds were systematically investigated. Finite element analyses (FEA) were conducted on a femoral segmental defect model stabilised with a bone plate, and multiple porosity gradient strategies were compared against a corresponding uniform scaffold composed of body-centred cubic (BCC) unit cells. Scaffolds composed of titanium alloy (Ti-6Al-4V), bioactive glass (45S5 Bio-glass), and polylactic acid (PLA) were evaluated to capture a range of material stiffnesses. Introducing porosity gradients consistently enhanced the mean octahedral shear strain within the scaffold, particularly in regions adjacent to the fixation plate affected by stress shielding. The magnitude of mechanical stimulus improvement increased with both greater porosity gradient magnitudes and higher gradient resolution. These improvements were more pronounced in stiffer materials, such as Ti-6Al-4V, emphasising the critical interplay between scaffold material properties and architectural design. These findings highlight the importance of tailoring both porosity profiles and material selection to optimise scaffold mechanics for bone regeneration.2025-10-31T10:56:14ZAnson Wen Han CheongVahid BadaliSean KielyIman RoohaniYang JiangJianguang FangAli Entezarihttp://arxiv.org/abs/2510.27282v1Near-perfect efficiency in X-ray phase microtomography2025-10-31T08:49:59ZX-ray microtomography at synchrotron sources is fundamentally limited by the high radiation dose applied to the samples, which restricts investigations to non-native tissue states and thereby compromises the biological relevance of the resulting data. The limitation stems from inefficient indirect detection schemes that require prolonged exposures. Efforts to extract additional contrast through multimodal techniques, like modulation-based imaging, worsen the problem by requiring multiple tomographic scans. In addition, the techniques suffer from low modulator pattern visibility, which reduces measurement efficiency and sensitivity. We address both the detection efficiency and modulation visibility challenges using a novel setup that combines an X-ray waveguide, a structured phase modulator, and a photon-counting detector. Our approach simultaneously achieves near-theoretical limits in both visibility (95%) and quantum efficiency (98%), thereby enabling dose-efficient multimodal microtomography at single-micrometer resolution. This advance will enable new classes of experiments on native-state biological specimens with the potential to advance biomedical research, disease diagnostics, and our understanding of tissue structure in physiological environments.2025-10-31T08:49:59ZDominik JohnGregor BreitenhuberSami WirtensohnFranziska HinterdoblerLuka GaetaniSara SavatovićJens LuchtMarkus OsterhoffMarina EckermannTim SaldittJulia Herzen10.1364/OPTICA.584432http://arxiv.org/abs/2510.26928v1Ultra-High Dose-Rates, the FLASH Effect, and Hydrogen Peroxide Yields: Do Experiments and Simulations Really Disagree?2025-10-30T18:36:41ZRadiation chemistry of model systems irradiated with ultra-high dose-rates (UHDR) is key to obtain a mechanistic understanding of the sparing of healthy tissue, which is called the FLASH effect. It is envisioned to be used for efficient treatment of cancer by FLASH radiotherapy. However, it seems that even the most simple model systems, water irradiated with varying dose-rates (DR), pose a challenge. This became evident, as differences within measured and predicted hydrogen peroxide (H2O2) yields (g-values) for exposure of liquid samples to conventional DR and UHDR were reported. Many of the recently reported values contradict older experiments and current Monte-Carlo simulations(MCS). In the present work, we aim to identify possible reasons of these discrepancies and propose ways to overcome this issue. Hereby a short review of recent and classical literature concerning experimental and simulational studies is performed. The studies cover different radiation sources, from gamma rays, high-energy electrons, heavy particles (protons and ions) with low and high linear energy transfer (LET), and samples of hypoxic & oxygenated water, with cosolutes such as bovine-serum albumine (BSA). Results are for additional experimental parameters, such as solvent, sample container and analysis methods used to determine the respective g-values of H2O2. Similarly the parameter of the MCS by the step-by-step approach, or the independent-reaction time (IRT) method are discussed. Here, UHDR induced modification of the radical-radical interaction and dynamics, not governed by diffusion processes, may cause problems. Approaches to test these different models are highlighted to allow progress: by making the step from a purely descriptive discourse of the effects observed, towards testable models, which should clarify the reasons of how and why such a disagreement came to light in the first place.2025-10-30T18:36:41Z16 pagesMarc Benjamin Hahnhttp://arxiv.org/abs/2510.26903v1PF-DAformer: Proximal Femur Segmentation via Domain Adaptive Transformer for Dual-Center QCT2025-10-30T18:07:56ZQuantitative computed tomography (QCT) plays a crucial role in assessing bone strength and fracture risk by enabling volumetric analysis of bone density distribution in the proximal femur. However, deploying automated segmentation models in practice remains difficult because deep networks trained on one dataset often fail when applied to another. This failure stems from domain shift, where scanners, reconstruction settings, and patient demographics vary across institutions, leading to unstable predictions and unreliable quantitative metrics. Overcoming this barrier is essential for multi-center osteoporosis research and for ensuring that radiomics and structural finite element analysis results remain reproducible across sites. In this work, we developed a domain-adaptive transformer segmentation framework tailored for multi-institutional QCT. Our model is trained and validated on one of the largest hip fracture related research cohorts to date, comprising 1,024 QCT images scans from Tulane University and 384 scans from Rochester, Minnesota for proximal femur segmentation. To address domain shift, we integrate two complementary strategies within a 3D TransUNet backbone: adversarial alignment via Gradient Reversal Layer (GRL), which discourages the network from encoding site-specific cues, and statistical alignment via Maximum Mean Discrepancy (MMD), which explicitly reduces distributional mismatches between institutions. This dual mechanism balances invariance and fine-grained alignment, enabling scanner-agnostic feature learning while preserving anatomical detail.2025-10-30T18:07:56Z22 Pages, 5 Tables, 10 Figures. The combination of GRL and MMD achieved the most balanced performance, reducing contour deviations and enhancing surface smoothnessRochak DhakalChen ZhaoZixin ShiJoyce H. KeyakTadashi S. KanekoKuan-Jui SuHui ShenHong-Wen DengWeihua Zhouhttp://arxiv.org/abs/2510.26668v1Zoeppritz equations: from seismology to medical exploration2025-10-30T16:37:32ZMore than a century ago, Karl Bernhard Zoeppritz derived the equations that determine the reflected and transmitted coefficients at a planar interface for an incident seismic wave. The coefficients so obtained are a function of the elastic parameters of the media on each side of the interface and the angle of incidence. Approximations of the equations have been proposed and used in geophysical exploration, however, full use of the equations and their generalization to multiple layers could offer richer information about the properties of the media and be helpful in medical diagnosis via ultrasound. In this work, we investigate how to extract information from the angle-dependent reflection coefficients, including critical angles and the wave distortion at the interface between two and three media. It is shown that it is possible to separate the effect of density from speed of sound mismatch by measuring amplitudes as a function of angle of incidence (AVA). And examining the critical angle and waveform distortion of the reflected waves can reveal the thickness of an intermediate layer, even with subwavelength resolution. These studies could be integrated into medical imaging and also into the training of artificial intelligence systems that assist in diagnosis. In particular, they could help prevent cerebrovascular accidents by early detection of the formation and hardening of plaque in the arteries that irrigate the brain.2025-10-30T16:37:32ZHarry G. SaavedraRamiro Moro10.33017/RevECIPeru2025.0008/http://arxiv.org/abs/2510.26563v1Fraction-variant VMAT planning for patients with complex gynecological and head-and-neck cancer2025-10-30T14:53:19ZBackground and Purpose: Increasing the number of arcs in volumetric modulated arc therapy (VMAT) allows for better intensity modulation and may improve plan quality. However, this leads to longer delivery times, which may cause patient discomfort and increase intra-fractional motion. In this study, it was investigated whether the delivery of different VMAT plans in different fractions may improve the dosimetric quality and delivery efficiency for the treatment of patients with complex tumor geometries.
Materials and Methods: A direct aperture optimization algorithm was developed which allows for the simultaneous optimization of different VMAT plans to be delivered in different fractions, based on their cumulative physical dose. Each VMAT plan is constrained to deliver a uniform dose within the target volume, such that the entire treatment does not alter the fractionation scheme and is robust against inter-fractional setup errors. This approach was evaluated in-silico for ten patients with gynecological and head-and-neck cancer.
Results: For all patients, fraction-variant treatments achieved better target coverage and reduced the dose to critical organs-at-risk compared to fraction-invariant treatments that deliver the same plan in every fraction, where the dosimetric benefit was shown to increase with the number of different plans to be delivered. In addition, 1-arc and 2-arc fraction-variant treatments could approximate the dosimetric quality of 3-arc fraction-invariant treatments, while reducing the delivery time from 180 s to 60 s and 120 s, respectively.
Conclusions: Fraction-variant VMAT treatments may achieve excellent dosimetric quality for patients with complex tumor geometries, while keeping the delivery time per fraction viable.2025-10-30T14:53:19ZNathan TorelliMadalyne DayJan Unkelbach