https://arxiv.org/api/aaJ82S7xUlWa/jI3XyWXJfVcXOw2026-06-24T10:42:28Z900175015http://arxiv.org/abs/2511.03763v1Dexterous Intramyocardial Needle Ablation (d-INA): Design, Fabrication, and In-Vivo Validation2025-11-05T13:45:21ZRadiofrequency ablation is widely used to prevent ventricular tachycardia (VT) by creating lesions to inhibit arrhythmias; however, the current surface ablation catheters are limited in creating lesions that are deeper within the left ventricle (LV) wall. Intramyocardial needle ablation (INA) addresses this limitation by penetrating the myocardium and delivering energy from within. Yet, existing INA catheters lack adequate dexterity to navigate the highly asymmetric, trabeculated LV chamber and steer around papillary structures, limiting precise targeting. This work presents a novel dexterous INA (d-INA) toolset designed to enable effective manipulation and creation of deep ablation lesions. The system consists of an outer sheath and an inner catheter, both bidirectionally steerable, along with an integrated ablation needle assembly. Benchtop tests demonstrated that the sheath and catheter reached maximum bending curvatures of 0.088~mm$^{-1}$ and 0.114~mm$^{-1}$, respectively, and achieved stable C-, S-, and non-planar S-shaped configurations. Ex-vivo studies validated the system's stiffness modulation and lesion-creation capabilities. In-vivo experiments in two swine demonstrated the device's ability to reach previously challenging regions such as the LV summit, and achieved a 219\% increase in ablation depth compared with a standard ablation catheter. These results establish the proposed d-INA as a promising platform for achieving deep ablation with enhanced dexterity, advancing VT treatment.2025-11-05T13:45:21ZChang ZhouCharles P. HongYifan WangEhud J. SchmidtJunichi TokudaAravindan KolandaiveluYue Chenhttp://arxiv.org/abs/2312.05063v4Individualizing Glioma Radiotherapy Planning by Optimization of Data and Physics-Informed Discrete Loss2025-11-04T22:02:05ZBrain tumor growth is unique to each glioma patient and extends beyond what is visible in imaging scans, infiltrating surrounding brain tissue. Understanding these hidden patient-specific progressions is essential for effective therapies. Current treatment plans for brain tumors, such as radiotherapy, typically involve delineating a uniform margin around the visible tumor on pre-treatment scans to target this invisible tumor growth. This "one size fits all" approach is derived from population studies and often fails to account for the nuances of individual patient conditions. We present the GliODIL framework, which infers the full spatial distribution of tumor cell concentration from available multi-modal imaging, leveraging a Fisher-Kolmogorov type physics model to describe tumor growth. This is achieved through the newly introduced method of Optimizing the Discrete Loss, where both data and physics-based constraints are softly assimilated into the solution. Our test dataset comprises 152 glioblastoma patients with pre-treatment imaging and post-treatment follow-ups for tumor recurrence monitoring. By blending data-driven techniques with physics-based constraints, GliODIL enhances recurrence prediction in radiotherapy planning, challenging traditional uniform margins and strict adherence to the Fisher-Kolmogorov partial differential equation model, which is adapted for complex cases.2023-12-08T14:32:14ZAccepted for publication in Nature Communications (DOI: 10.1038/s41467-025-60366-4)Michal BalcerakJonas WeidnerPetr KarnakovIvan EzhovSergey LitvinovPetros KoumoutsakosTamaz AmiranashviliRay Zirui ZhangJohn S. LowengrubBene WiestlerBjoern Menzehttp://arxiv.org/abs/2511.02314v1Large-scale automatic carbon ion treatment planning for head and neck cancers via parallel multi-agent reinforcement learning2025-11-04T06:57:31ZHead-and-neck cancer (HNC) planning is difficult because multiple critical organs-at-risk (OARs) are close to complex targets. Intensity-modulated carbon-ion therapy (IMCT) offers superior dose conformity and OAR sparing but remains slow due to relative biological effectiveness (RBE) modeling, leading to laborious, experience-based, and often suboptimal tuning of many treatment-planning parameters (TPPs). Recent deep learning (DL) methods are limited by data bias and plan feasibility, while reinforcement learning (RL) struggles to efficiently explore the exponentially large TPP search space. We propose a scalable multi-agent RL (MARL) framework for parallel tuning of 45 TPPs in IMCT. It uses a centralized-training decentralized-execution (CTDE) QMIX backbone with Double DQN, Dueling DQN, and recurrent encoding (DRQN) for stable learning in a high-dimensional, non-stationary environment. To enhance efficiency, we (1) use compact historical DVH vectors as state inputs, (2) apply a linear action-to-value transform mapping small discrete actions to uniform parameter adjustments, and (3) design an absolute, clinically informed piecewise reward aligned with plan scores. A synchronous multi-process worker system interfaces with the PHOENIX TPS for parallel optimization and accelerated data collection. On a head-and-neck dataset (10 training, 10 testing), the method tuned 45 parameters simultaneously and produced plans comparable to or better than expert manual ones (relative plan score: RL $85.93\pm7.85%$ vs Manual $85.02\pm6.92%$), with significant (p-value $<$ 0.05) improvements for five OARs. The framework efficiently explores high-dimensional TPP spaces and generates clinically competitive IMCT plans through direct TPS interaction, notably improving OAR sparing.2025-11-04T06:57:31ZJueye ZhangChao YangYoufang LaiKai-Wen LiWenting YanYunzhou XiaHaimei ZhangJingjing ZhouGen YangChen LinTian LiYibao Zhanghttp://arxiv.org/abs/2504.18700v3Prior-Adapted Progressive Time-Resolved CBCT Reconstruction Using a Dynamic Reconstruction and Motion Estimation Method2025-11-04T05:04:15ZCone-beam CT (CBCT) provides on-board volumetric anatomy for image guidance and treatment adaptation in radiotherapy. To compensate for respiration-induced anatomical motion, time-resolved CBCT is highly desired to capture the spatiotemporal anatomical variations but faces challenges in accuracy and efficiency due to substantial optimization needed in image reconstruction and motion modeling. We proposed a fast time-resolved CBCT reconstruction framework, based on a dynamic reconstruction and motion estimation method with new reconstructions initialized and conditioned on prior reconstructions in an adaptive fashion (DREME-adapt). DREME-adapt reconstructs a time-resolved CBCT sequence from a fractional standard CBCT scan while simultaneously generating a machine learning-based motion model that allows single-projection-driven intra-treatment CBCT estimation and motion tracking. Via DREME-adapt, a virtual fraction is generated from a pre-treatment 4D-CT set of each patient for a clean, 'cold-start' reconstruction. For subsequent fractions of the same patient, DREME-adapt uses pre-derived motion models and reference CBCTs as initializations to drive a 'warm-start' reconstruction, based on a lower-cost refining strategy. Three strategies: DREME-cs which drops the 'warm-start' component, DREME-adapt-vfx which uses a fixed initialization (virtual fraction's reconstruction results), and DREME-adapt-pro which initialize reconstructions through a progressive daisy chain scheme (virtual fraction for fraction 1, fraction 1 for fraction 2, and so on), were evaluated on a digital phantom study and a patient study. DREME-adapt allows fast and accurate time-resolved CBCT reconstruction and enhances the clinical adoption potential of the DREME framework.2025-04-25T21:25:53Z34 pages, 8 figuresRuizhi ZuoHua-Chieh ShaoYou Zhanghttp://arxiv.org/abs/2511.02259v1CT density estimation and beam hardening correction for single material objects using reference scans - a simulation and experimental study2025-11-04T04:57:06ZWe describe the results from a simulation and experimental study of density estimation and beam hardening correction for Bremsstrahlung source computed tomography scan of objects made of a single material. The correction is done using transmission scans of a number of sheets of known thickness and density and made of the same material as the object under test.2025-11-04T04:57:06Z10 pagesNikhil Deshmukhhttp://arxiv.org/abs/2511.02223v1Quantitative Risk Assessment in Radiation Oncology via LLM-Powered Root Cause Analysis of Incident Reports2025-11-04T03:33:56ZBackground: Modern large language models (LLMs) offer powerful reasoning that converts narratives into structured, taxonomy-aligned data, revealing patterns across planning, delivery, and verification. Embedded as agentic tools, LLMs can assist root-cause analysis and risk assessment (e.g., failure mode and effect analysis FMEA), produce auditable rationales, and draft targeted mitigation actions.
Methods: We developed a data-driven pipeline utilizing an LLM to perform automated root cause analysis on 254 institutional safety incidents. The LLM systematically classified each incident into structured taxonomies for radiotherapy pathway steps and contributory factors. Subsequent quantitative analyses included descriptive statistics, Analysis of Variance (ANOVA), multiple Ordinal Logistic Regression (OLR) analyses to identify predictors of event severity, and Association Rule Mining (ARM) to uncover systemic vulnerabilities.
Results: The high-level Ordinal Logistic Regression (OLR) models identified specific, significant drivers of severity. The Pathway model was statistically significant (Pseudo R2 = 0.033, LR p = 0.015), as was the Responsibility model (Pseudo R2 = 0.028, LR p < 0.001). Association Rule Mining (ARM) identified high-confidence systemic rules, such as "CF5 Teamwork, management and organisational" (n = 8, Conf = 1.0) and the high-frequency link between "(11) Pre-treatment planning process" and "CF2 Procedural" (n = 152, Conf = 0.916).
Conclusion: The LLM-powered, data-driven framework provides a more objective and powerful methodology for risk assessment than traditional approaches. Our findings empirically demonstrate that interventions focused on fortifying high-risk process steps and mitigating systemic failures are most effective for improving patient safety.2025-11-04T03:33:56ZYuntao WangSiamak P. Najad-DavaraniElizabeth BossartMatthew T. StudenskiMariluz De OrnelasYunze Yanghttp://arxiv.org/abs/2511.02212v1High-Resolution Magnetic Particle Imaging System Matrix Recovery Using a Vision Transformer with Residual Feature Network2025-11-04T03:03:39ZThis study presents a hybrid deep learning framework, the Vision Transformer with Residual Feature Network (VRF-Net), for recovering high-resolution system matrices in Magnetic Particle Imaging (MPI). MPI resolution often suffers from downsampling and coil sensitivity variations. VRF-Net addresses these challenges by combining transformer-based global attention with residual convolutional refinement, enabling recovery of both large-scale structures and fine details. To reflect realistic MPI conditions, the system matrix is degraded using a dual-stage downsampling strategy. Training employed paired-image super-resolution on the public Open MPI dataset and a simulated dataset incorporating variable coil sensitivity profiles. For system matrix recovery on the Open MPI dataset, VRF-Net achieved nRMSE = 0.403, pSNR = 39.08 dB, and SSIM = 0.835 at 2x scaling, and maintained strong performance even at challenging scale 8x (pSNR = 31.06 dB, SSIM = 0.717). For the simulated dataset, VRF-Net achieved nRMSE = 4.44, pSNR = 28.52 dB, and SSIM = 0.771 at 2x scaling, with stable performance at higher scales. On average, it reduced nRMSE by 88.2%, increased pSNR by 44.7%, and improved SSIM by 34.3% over interpolation and CNN-based methods. In image reconstruction of Open MPI phantoms, VRF-Net further reduced reconstruction error to nRMSE = 1.79 at 2x scaling, while preserving structural fidelity (pSNR = 41.58 dB, SSIM = 0.960), outperforming existing methods. These findings demonstrate that VRF-Net enables sharper, artifact-free system matrix recovery and robust image reconstruction across multiple scales, offering a promising direction for future in vivo applications.2025-11-04T03:03:39ZBiomedical Signal Processing and Control 113 (2026) 108990Abuobaida M. KhairWenjing JiangYousuf Babiker M. OsmanWenjun XiaXiaopeng Ma10.1016/j.bspc.2025.108990http://arxiv.org/abs/2511.02090v1Characterizing the Reliability of a Novel Upright CT for Proton Therapy2025-11-03T22:01:59ZPurpose: To evaluate reliability of upright CT for proton dose calculation and feasibility of a simplified phantom configuration for accelerated routine QA. Methods: A calibration phantom was scanned on an upright CT following consensus guidelines for 14 sessions/7 months. CT number repeatability was assessed by standard deviation (SD). Stopping power ratio (SPR) look-up table was derived. Phantom size dependency was assessed. The simplified phantom configuration was scanned for 15 sessions/8 months. Repeatability was assessed. CT numbers and SPR were compared with consensus configuration. Both configurations were scanned on a recumbent CT to validate the findings. An anthropomorphic phantom was scanned on upright and recumbent CT. Targets were drawn mimicking spine and prostate tumor. Proton plans were developed using pencil beam scanning techniques and robust optimization. Equivalence of dose calculation were assessed via controlled comparisons. Results: Simplified configuration measured all CT numbers in 1 scan vs 5 for consensus guidelines. Upright CT demonstrated excellent longitudinal stability (inter- and intrasession SD <4.9 HU and 1.6 HU, respectively). Size dependency was identified with significant (p<.05) differences in CT numbers, propagated to $Δ$SPR <5.3%. Significant (p<.05) differences were found comparing upright CT numbers measured by 2 configurations ($Δ$SPR<2.6%). Recumbent CT showed smaller $Δ$SPR (<0.7%). Both dosimetric comparison showed local differences (<8% of prescription dose) while clinical equivalence was found with target coverage differences <0.2% and gamma pass rates=100% at 3 mm/3% for all controlled comparison of different CT machines and phantom configurations. Conclusions: The upright CT demonstrated reliability to support adaptive proton therapy. The simplified configuration shows feasibility for rapid QA.2025-11-03T22:01:59ZYuhao YanJordan SlagowskiJessica MillerJohn HayesCarson HoffmanMinglei KangCarri Glide-Hursthttp://arxiv.org/abs/2511.02051v1Towards Continuous-variable Quantum Neural Networks for Biomedical Imaging2025-11-03T20:35:47ZContinuous-variable (CV) quantum computing offers a promising framework for scalable quantum machine learning, leveraging optical systems with infinite-dimensional Hilbert spaces. While discrete-variable (DV) quantum neural networks have shown remarkable progress in various computer vision tasks, CV quantum models remain comparatively underexplored. In this work, we present a feasibility study of continuous-variable quantum neural networks (CV-QCNNs) applied to biomedical image classification. Utilizing photonic circuit simulation frameworks, we construct CV quantum circuits composed of Gaussian gates, such as displacement, squeezing, rotation, and beamsplitters to emulate convolutional behavior. Our experiments are conducted on the MedMNIST dataset collection, a set of annotated medical image benchmarks for multiple diagnostic tasks. We evaluate CV-QCNN's performance in terms of classification accuracy, model expressiveness, and resilience to Gaussian noise, comparing against classical CNNs and equivalent DV quantum circuits. This study aims to identify trade-offs between DV and CV paradigms for quantum-enhanced medical imaging. Our results highlight the potential of continuous-variable models and their viability for future computer-aided diagnosis systems.2025-11-03T20:35:47Z21 pages, 17 Figures, 3 TablesDaniel Alejandro LopezOscar MontielOscar CastilloMiguel Lopez-Montielhttp://arxiv.org/abs/2511.01642v1A Multiscale Framework for In Silico Thrombus Generation and Photoacoustic Simulations2025-11-03T14:53:55ZThrombus microstructure plays a critical role in determining the treatment success for thrombus-related diseases such as stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. Here, we present REFINE, a topology-driven framework for generating in silico thrombi replicating its key replicating their key microstructural traits. REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be modeled in silico. These findings highlight that multiscale photoacoustic simulation is a powerful tool for characterizing tissue microstructure and that our framework enables in silico thrombi analysis and diagnostic imaging strategy development2025-11-03T14:53:55ZGhodsi, H., Cardona, S., Fereidoonnezhad, B., Iskander-Rizk, S., Journal of Physics Photonics, 2025Hamed GhodsiSara CardonaBehrooz FereidoonnezhadSophinese Iskander-Rizk10.1088/2515-7647/ae1b54http://arxiv.org/abs/2511.01580v1Microdosimetry Aspects in Diffusing Alpha-emitters Radiation Therapy. Part I: Effect of Broad Nucleus Size Distributions2025-11-03T13:51:38ZDiffusing alpha-emitters Radiation Therapy ("Alpha DaRT") is a new treatment modality focusing on the use of alpha particles against solid tumors. The introduction of Alpha DaRT in clinical settings calls for the development of detailed tumor dosimetry, which addresses biological responses such as cell survival and tumor control probabilities at the microscopic scale. In this study, we present a microdosimetric model that links the macroscopic alpha dose, cell survival, and tumor control probability while explicitly accounting for broad distributions of spherical nucleus radii. The model combines analytic expressions for nucleus-hit statistics by alpha particles with Monte Carlo-based specific-energy deposition to compute survival for cells whose nucleus radii are sampled from artificial and empirically derived distributions. The results indicate that introducing finite-width nucleus size distributions causes survival curves to depart from the exponential trend observed for uniform cell populations. We show that the width of the nucleus size distribution strongly influences the survival gap between radiosensitive and radioresistant populations, diminishing the influence of intrinsic radiosensitivity on cell survival. Tumor control probability is highly sensitive to the minimal nucleus size included in the size distribution, indicating that realistic lower thresholds are essential for credible predictions.Our findings highlight the importance of careful characterization of clonogenic nucleus sizes, with particular attention to the smallest nuclei represented in the data. Without addressing these small-nucleus contributions, tumor control probability may be substantially underestimated. Incorporating realistic nucleus size variability into microdosimetric calculations is a key step toward more accurate tumor control predictions for Alpha DaRT and other alpha-based treatment modalities.2025-11-03T13:51:38Z15 pages, 10 figures, submitted to Physics in Medicine & Biology on October 29, 2025Yevgeniya KorotinskyLior Arazihttp://arxiv.org/abs/2509.04528v2HEEPidermis: a versatile SoC for BioZ recording2025-11-03T09:19:47ZBiological impedance (BioZ) is an information-packed modality that allows for non-invasive monitoring of health and emotional state. Currently, most research involving tissue impedance is based on bulky or fixed-purpose hardware, which limits the scope of research and the possibilities of experiments. In this work, we present HEEPidermis: a System-on-Chip (SoC) which integrates all the blocks needed for tissue impedance measurement, including two 8-bit, arbitrary-signal current DACs, two VCO-based ADCs, and a RISC-V CPU to enable on-chip feature extraction for closed-loop operation. An event-based sub-sampler improves storage and energy efficiency for long-term recording. In addition to the versatile SoC, the digital back-end and behavioral models of the analog front-end are open-source, allowing fast system-level simulations or repurposing. The SoC was taped out on TSMC 65 nm LP process.2025-09-03T19:34:37ZJuan SaprizaBeatrice GrassanoAlessio NaclerioFilippo QuadriTommaso TerzanoDavid MallasénDavide SchiavoneRobin LeplaeJérémie MoulletAlexandre LevisseChristoph MüllerMariagrazia GrazianoMatías MiguezDavid Atienzahttp://arxiv.org/abs/2511.01269v1NIR-II Fluorescence Project Technology for Augmented Reality Surgical Navigation2025-11-03T06:42:37ZNIR-II fluorescence imaging provides superior tissue penetration and clarity, yet its clinical use in surgical navigation is hindered by a critical workflow issue. Surgeons must divert their attention between the operative field and external monitors, increasing cognitive load and disrupting procedures. Current strategies have failed to resolve this fundamental problem. Here, we developed a co-axial NIR-II fluorescence projection navigation system to enable real-time, in situ visualization. This system creates an intraoperative augmented reality by directly projecting high-precision, pseudocolored fluorescence images onto the surgical field, spatially integrating functional signals with patient anatomy. Validated through in vitro, in vivo, and clinical patient studies, our system eliminates visual field switching, reduces intraoperative distraction, and preserves natural stereoscopic vision. This approach represents a paradigm shift toward a more coherent, efficient, and ergonomically optimized optical imaging modality for surgical navigation.2025-11-03T06:42:37ZYuhuang ZhangXiaolong LiuZihang LiuChao LiuJie YangJian FengSiying SunZhe FengXiaoxiao FanHui LinJun Qianhttp://arxiv.org/abs/2511.01052v1Knowledge Elicitation with Large Language Models for Interpretable Cancer Stage Identification from Pathology Reports2025-11-02T19:00:40ZCancer staging is critical for patient prognosis and treatment planning, yet extracting pathologic TNM staging from unstructured pathology reports poses a persistent challenge. Existing natural language processing (NLP) and machine learning (ML) strategies often depend on large annotated datasets, limiting their scalability and adaptability. In this study, we introduce two Knowledge Elicitation methods designed to overcome these limitations by enabling large language models (LLMs) to induce and apply domain-specific rules for cancer staging. The first, Knowledge Elicitation with Long-Term Memory (KEwLTM), uses an iterative prompting strategy to derive staging rules directly from unannotated pathology reports, without requiring ground-truth labels. The second, Knowledge Elicitation with Retrieval-Augmented Generation (KEwRAG), employs a variation of RAG where rules are pre-extracted from relevant guidelines in a single step and then applied, enhancing interpretability and avoiding repeated retrieval overhead. We leverage the ability of LLMs to apply broad knowledge learned during pre-training to new tasks. Using breast cancer pathology reports from the TCGA dataset, we evaluate their performance in identifying T and N stages, comparing them against various baseline approaches on two open-source LLMs. Our results indicate that KEwLTM outperforms KEwRAG when Zero-Shot Chain-of-Thought (ZSCOT) inference is effective, whereas KEwRAG achieves better performance when ZSCOT inference is less effective. Both methods offer transparent, interpretable interfaces by making the induced rules explicit. These findings highlight the promise of our Knowledge Elicitation methods as scalable, high-performing solutions for automated cancer staging with enhanced interpretability, particularly in clinical settings with limited annotated data.2025-11-02T19:00:40ZYeawon LeeChristopher C. YangChia-Hsuan ChangGrace Lu-Yaohttp://arxiv.org/abs/2506.10797v2Modality-AGnostic Image Cascade (MAGIC) for Multi-Modality Cardiac Substructure Segmentation2025-11-02T18:41:28ZCardiac substructure delineation is emerging in treatment planning to minimize the risk of radiation-induced heart disease. Deep learning offers efficient methods to reduce contouring burden but currently lacks generalizability across different modalities and overlapping structures. This work introduces and validates a Modality-AGnostic Image Cascade (MAGIC) deep-learning pipeline for comprehensive and multi-modal cardiac substructure segmentation. MAGIC is implemented through replicated encoding and decoding branches of an nnU-Net backbone to handle multi-modality inputs and overlapping labels. First benchmarked on the multi-modality whole-heart segmentation (MMWHS) dataset including cardiac CT-angiography (CCTA) and MR modalities, twenty cardiac substructures (heart, chambers, great vessels (GVs), valves, coronary arteries (CAs), and conduction nodes) from clinical simulation CT (Sim-CT), low-field MR-Linac, and cardiac CT-angiography (CCTA) modalities were delineated to train semi-supervised (n=151), validate (n=15), and test (n=30) MAGIC. For comparison, fourteen single-modality comparison models (two MMWHS modalities and four subgroups across three clinical modalities) were trained. Methods were evaluated for efficiency and against reference contours through the Dice similarity coefficient (DSC) and two-tailed Wilcoxon Signed-Rank test (p<0.05). Average MMWHS DSC scores across CCTA and MR inputs were 0.88(0.08) and 0.87(0.04) respectively with significant improvement over unimodal baselines. Average 20-structure DSC scores were 0.75(0.16) for Sim-CT, 0.68(0.21) for MR-Linac, and 0.80(0.16) for CCTA. Furthermore, >80% and >70% reductions in training time and parameters were achieved, respectively. MAGIC offers an efficient, lightweight solution capable of segmenting multiple image modalities and overlapping structures in a single model without compromising segmentation accuracy.2025-06-12T15:10:24ZNicholas SummerfieldQisheng HeAlex KuoAhmed I. GhanemSimeng ZhuChase RuffJoshua PanAnudeep KumarPrashant NagpalJiwei ZhaoMing DongCarri K. Glide-Hurst