https://arxiv.org/api/zJynSlZVn2wB4eiZmwQ5HA2bH042026-03-30T10:19:08Z87777515http://arxiv.org/abs/2603.06314v1Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients2026-03-06T14:16:38ZProbabilistic evaluation improves the trade-off between target coverage and OAR sparing in IMPT but remains computationally demanding. This study proposes sparse probabilistic evaluation (SPE), a computationally efficient approach integrated into a clinical TPS.
Clinical plans of 20 IMPT HNC patients treated in 2024 were included. SPE used a predefined setup and range error grid with Monte Carlo computed dose distributions. Two grid settings were evaluated: the maximum error Emax (3$σ$ or 4$σ$) and the number of setup error points nsetup (7, 33, 123). Accuracy and duration of SPE with each grid were evaluated in the calibration group (5 patients). 1000 treatments with normally distributed random ($σ$ = 1 mm) and systematic ($σ$ = 0.92 mm) setup and range ($σ$ = 1.5%) errors were simulated. The dose distribution of the nearest error point in the grid was assigned to each fraction. Probability distributions derived from SPE were compared with those from a reference based on 35,000 Monte Carlo calculations. The found optimal grid (Emax = 3$σ$, nsetup = 33) was applied to the validation group (15 patients).
Accuracy of SPE in the calibration group increased significantly as the number of error points increased from 7 (tavg = 2 minutes) to 33 (tavg = 9 minutes), with no further improvement between 33 and 123 (tavg = 27 minutes) error points. Increasing Emax only improved accuracy for values above the 98th percentile. Applying SPE to the validation group resulted in median errors of 0.02 Gy RBE (range:-0.11 to 0.07) for the 10th percentile of the D99.8%, CTV distribution and 0.0 Gy RBE (range:-0.14 to 0.23) for the 95th percentile of the D0.03cc,SpinalCord Core distribution.
Sparse probabilistic evaluation achieves sufficient accuracy while requiring clinically acceptable computation times, paving the way for probabilistic evaluation in clinical practice.2026-03-06T14:16:38ZJenneke I. de JongSteven J. M. HabrakenAlbin FredrikssonJohan SundströmErik EngwallSebastiaan BreedveldMischa S. Hoogemanhttp://arxiv.org/abs/2603.05796v1CBCT-Based Synthetic CT Generation Using Conditional Flow Matching Model2026-03-06T01:04:47ZDaily or weekly cone-beam computed tomography (CBCT) is employed in image-guided radiotherapy (IGRT) for precise patient alignment. However, its clinical utility in quantitative tasks is hindered by severe artifacts and inaccurate Hounsfeld unit (HU). It is essential to enhance CBCT image quality to a level comparable with that of conventional CT scans. This study proposed a conditional flow matching model that gradually transforms a sample from normal distribution to the corresponding CT sample conditioned on the input CBCT image. The proposed model was trained using CBCT and deformed planning CT (dpCT) image pairs in a supervised learning scheme. The feasibility of the conditional flow matching model was verified using studies of brain, head-and-neck (HN), and lung patients. The quantitative performance was evaluated using three metrics, including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). The proposed flow matching model was also compared to other flow matching and diffusion-based generative models for sCT generation. The proposed flow matching model effectively reduced multiple types of artifacts on CBCT images in all the studies. In the study of brain patient, the MAE, PSNR, and NCC of the sCT were improved to 26.02 HU, 32.35 dB, and 0.99, respectively, from 40.63 HU, 27.87 dB, and 0.98 on the CBCT images. In the study of HN patient, the metrics were improved to 33.17 HU, 28.68 dB, 0.98 from 38.99 HU, 27.00 dB, 0.98. In the lung patient study, the metrics were 25.09 HU, 32.81 dB, 0.99 and 32.90 HU, 30.48 dB, 0.98 for sCT and CBCT, respectively. The proposed conditional flow matching model effectively synthesizes high-quality CT-like images from CBCT, achieving accurate HU representation and artifact reduction. This enables more reliable organ segmentation and dose calculation in CBCT-guided online ART workflows.2026-03-06T01:04:47ZJunbo PengHuiqiao XieTonghe WangXiangyang TangXiaofeng Yanghttp://arxiv.org/abs/2603.05658v1Ultra-high frequency ultrasound imaging and quantification of microvascular flow in xenograft renal cell carcinoma in an avian chorioallantoic membrane model2026-03-05T20:19:50ZPatient derived xenograft (PDX) tumor models initiated in avian chorioallantoic membranes (CAM) are under investigation to evaluate the effectiveness of therapeutic options with the objective of personalizing treatments. CAM PDXs paired with ultra-high frequency ultrasound (UHFUS) imaging could potentially constitute prospective high throughput assays that can rapidly assess tumor volume and vascular response to therapy. To date, little work has been conducted to adapt and validate UHFUS flow imaging methods to CAM tumor models, which have particular tissue motion challenges that affect microvascular flow detection. Here we report the development and evaluation of an imaging pipeline for UHFUS detection of microvascular flow in a CAM tumor model using interframe subtraction (IS) to suppress tissue clutter. The IS pipeline included a tissue motion compensation (MC) stage prior to clutter filtering and was compared to a singular value decomposition (SVD) clutter filter. The performance was evaluated using UHFUS data acquired in phantom and in vivo Sunitinib-treated renal cell carcinoma. MC substantially reduced tissue motion effects. MC+IS was comparable to MC+SVD filtering at detecting flow within tumors. The results for both IS and SVD filters were dependent on the details of implementation. The UHFUS imaging methods detected a significant decrease in blood flow metrics in treated versus control tumors. An effective imaging pipeline was developed for the assessment of the treatment response of CAM PDX models in a clinically relevant timeframe. The MC+IS approach implemented on B-scan image derived data is less computationally intensive and can be used with widely available UHFUS systems2026-03-05T20:19:50ZSara MarEmmanuel CherinJustin XuDavid E. Goertz Hon S. LeongChristine E. M. Demorehttp://arxiv.org/abs/2603.05247v1ICHOR: A Robust Representation Learning Approach for ASL CBF Maps with Self-Supervised Masked Autoencoders2026-03-05T15:01:11ZArterial spin labeling (ASL) perfusion MRI allows direct quantification of regional cerebral blood flow (CBF) without exogenous contrast, enabling noninvasive measurements that can be repeated without constraints imposed by contrast injection. ASL is increasingly acquired in research studies and clinical MRI protocols. Building on successes in structural imaging, recent efforts have implemented deep learning based methods to improve image quality, enable automated quality control, and derive robust quantitative and predictive biomarkers with ASL derived CBF. However, progress has been limited by variable image quality, substantial inter-site, vendor and protocol differences, and limited availability of labeled datasets needed to train models that generalize across cohorts. To address these challenges, we introduce ICHOR, a self supervised pre-training approach for ASL CBF maps that learns transferable representations using 3D masked autoencoders. ICHOR is pretrained via masked image modeling using a Vision Transformer backbone and can be used as a general-purpose encoder for downstream ASL tasks. For pre-training, we curated one of the largest ASL datasets to date, comprising 11,405 ASL CBF scans from 14 studies spanning multiple sites and acquisition protocols. We evaluated the pre-trained ICHOR encoder on three downstream diagnostic classification tasks and one ASL CBF map quality prediction regression task. Across all evaluations, ICHOR outperformed existing neuroimaging self-supervised pre-training methods adapted to ASL. Pre-trained weights and code will be made publicly available.2026-03-05T15:01:11ZXavier Beltran-UrbanoYiran LiXinglin ZengKatie R. JobsonManuel TasoChristopher A. BrownDavid A. WolkCorey T. McMillanIlya M. NashrallahPaul A. YushkevichZe WangJohn A. DetreSudipto Doluihttp://arxiv.org/abs/2505.19146v3Design of a Wearable Parallel Electrical Impedance Imaging System for Healthcare2026-03-05T13:01:13ZA wireless wearable Electrical Impedance Tomography (EIT) system has been developed utilizing the AD5933 chip to achieve real-time imaging of lung respiration. The system employs a voltage excitation method tailored to human impedance characteristics, injecting current by applying a known voltage and measuring the resulting current through the body. Additionally, specific measures have been implemented to effectively suppress signal oscillations and leakage currents caused by parasitic capacitances. To enhance data acquisition speed, the system employs five parallel AD5933 units, with multiple techniques implemented to ensure high synchronization during simultaneous measurements. Performance testing shows that the system achieves a signal-to-noise ratio greater than 50 dB, a relative standard deviation below 0.3%, and a reciprocity error under 0.8%. Imaging experiments using a water tank phantom, human lungs during breathing, and a resting human calf further demonstrate that this portable EIT system can accurately measure biological tissues with high precision and low cost.2025-05-25T13:46:18ZBowen LiZekun ChenXuefei ChenLuhao ZhangShili Lianghttp://arxiv.org/abs/2603.04955v1Uncertainty-aware Blood Glucose Prediction from Continuous Glucose Monitoring Data2026-03-05T08:49:43ZIn this work, we investigate uncertainty-aware neural network models for blood glucose prediction and adverse glycemic event identification in Type 1 diabetes. We consider three families of sequence models based on LSTM, GRU, and Transformer architectures, with uncertainty quantification enabled by either Monte Carlo dropout or through evidential output layers compatible with Deep Evidential Regression. Using the HUPA-UCM diabetes dataset for validation, we find that Transformer-based models equipped with evidential output heads provide the most effective uncertainty-aware framework, achieving consistently higher predictive accuracies and better-calibrated uncertainty estimates whose magnitudes significantly correlate with prediction errors. We further evaluate the clinical risk of each model using the recently proposed Diabetes Technology Society error grid, with risk categories defined by international expert consensus. Our results demonstrate the value of integrating principled uncertainty quantification into real-time machine-learning-based blood glucose prediction systems.2026-03-05T08:49:43Z19 pages, 10 figuresHai Siong Tanhttp://arxiv.org/abs/2603.04673v1sFRC for assessing hallucinations in medical image restoration2026-03-04T23:29:44ZDeep learning (DL) methods are currently being explored to restore images from sparse-view-, limited-data-, and undersampled-based acquisitions in medical applications. Although outputs from DL may appear visually appealing based on likability/subjective criteria (such as less noise, smooth features), they may also suffer from hallucinations. This issue is further exacerbated by a lack of easy-to-use techniques and robust metrics for the identification of hallucinations in DL outputs. In this work, we propose performing Fourier Ring Correlation (FRC) analysis over small patches and concomitantly (s)canning across DL outputs and their reference counterparts to detect hallucinations (termed as sFRC). We describe the rationale behind sFRC and provide its mathematical formulation. The parameters essential to sFRC may be set using predefined hallucinated features annotated by subject matter experts or using imaging theory-based hallucination maps. We use sFRC to detect hallucinations for three undersampled medical imaging problems: CT super-resolution, CT sparse view, and MRI subsampled restoration. In the testing phase, we demonstrate sFRC's effectiveness in detecting hallucinated features for the CT problem and sFRC's agreement with imaging theory-based outputs on hallucinated feature maps for the MR problem. Finally, we quantify the hallucination rates of DL methods on in-distribution versus out-of-distribution data and under increasing subsampling rates to characterize the robustness of DL methods. Beyond DL-based methods, sFRC's effectiveness in detecting hallucinations for a conventional regularization-based restoration method and a state-of-the-art unrolled method is also shown.2026-03-04T23:29:44Z16 pages; 14 figures; 1 Supplemental document. TechRxiv Preprints, 2025Prabhat KcRongping ZengNirmal SoniAldo Badano10.36227/techrxiv.171259560.02243347/v2http://arxiv.org/abs/2603.04233v1Continuous Ventricular Volumetric Quantification in Patients with Arrhythmias using Real-Time 3D CMR-MOTUS2026-03-04T16:15:44ZConventional cardiovascular magnetic resonance (CMR) cine imaging relies on binning multiple heartbeats into a single cardiac cycle, which fails in arrhythmic patients where beat-to-beat variability causes motion artifacts and loss of functional information. Real-time 2D imaging captures individual beats but lacks volumetric coverage for mapping arrhythmic cardiac dynamics. We present a 3D real-time motion-field reconstruction method enabling continuous volumetric assessment in patients with premature ventricular contractions (PVCs) using a free-running CMR protocol. CMR-MOTUS was extended to jointly reconstruct real-time 3D motion fields and a motion-corrected reference image from continuous, ungated, non-breath-held data acquired with a variable-density Cartesian OPRA trajectory. Beat-to-beat ejection fraction (EF) was computed by propagating a single segmentation through all frames using the reconstructed motion fields. The method was validated on a cardiac motion phantom and tested in four healthy volunteers and four PVC patients. Phantom EF closely matched ground truth (22.1 +/- 0.6 percent vs. 21.9 percent). In healthy volunteers, EF values agreed with 2D references and showed narrow distributions reflecting physiological consistency. In PVC patients, EF distributions were bimodal, with the lower mode corresponding to PVC beats with markedly reduced EF. ECG confirmed alignment between EF irregularities and PVC episodes. These results show that 3D real-time motion-field reconstruction enables continuous beat-to-beat volumetric quantification in arrhythmia, revealing functional heterogeneity that conventional binning obscures. The bimodal EF distributions capture the true hemodynamic impact of PVCs and may provide clinically relevant metrics for monitoring and treatment evaluation.2026-03-04T16:15:44ZThomas E. OlaussonMaarten L. TerpstraRizwan AhmadEdwin VersteegCasper BeijstYuchi HanMarco GuglielmoBirgitta K. VelthuisCornelis van den BergAlessandro Sbrizzihttp://arxiv.org/abs/2603.03916v1A review of ventral hernia biomechanics2026-03-04T10:24:45ZDespite advancements in surgical techniques, hernia recurrence rates remain high, underscoring the need for improved understanding of abdominal wall behaviour. While surgeons are aware of many factors contributing to hernia occurrence (e.g obesity, smoking, surgical technique or site infection), it would be of interest to consider it as a biomechanical pathology. Indeed, an abdominal hernia arises from an imbalance between abdominal wall deformability and applied forces. This review article discusses how biomechanics offer a quantitative framework for assessing healthy and damaged tissue behaviour, guiding personalised surgical strategies throughout the pre-, intra-, and post-operative periods. The abdominal wall is a dynamic, load-bearing structure, continuously subjected to intra-abdominal pressure and mechanical stress. Its biomechanical properties, including elasticity and resistance to loading forces, dictate its function and response to surgical intervention. The linea alba is the stiffest component experiencing the highest stress, while the abdominal wall's anisotropic nature influences deformation patterns. Various experimental and computational methods enable biomechanical characterisation. Hernias represent mechanical failures at anatomical weak points. While surgeons qualitatively evaluate abdominal wall's biomechanics by estimating deformation and closure forces, functional imaging (elastography, dynamic acquisitions) could provide objective biomechanical insights. Hernia formation alters abdominal wall biomechanics, inducing greater mobility and elasticity. Surgical repair fundamentally alters the biomechanics of the abdominal wall. The choice of defect's suturing technique, mesh properties, placement, overlap and fixation methods (e.g. suture, tacks) significantly influence mechanical outcomes. Surgical repair tends to restore physiological biomechanics by re-establishing force transmission and hernia-induced excessive mobility. Suturing techniques, mesh selection and placement influence mechanical outcomes. However, optimal results require implants with mechanical properties mimicking native tissue. Lightweight meshes (<70 g/m2) placed in a retrorectus position, combined with a small-bite suture technique, have been associated with lower recurrence rates and improved post-operative function. By bridging biomechanics with surgical practice, this review highlights how mechanical principles shape hernia formation, diagnosis, and repair. A deeper integration of biomechanical principles into surgical decision-making could refine hernia management and lead to patient-specific, mechanics-informed strategies. For surgeons, this knowledge is not just academic - it is practical and can make a difference to patient outcomes.2026-03-04T10:24:45ZJournal of the mechanical behavior of biomedical materials, In press, pp.107159Victoria JoppinLBA UMR T24, CRMBMCatherine MassonLBA UMR T24David BendahanCRMBMThierry BegeLBA UMR T24http://arxiv.org/abs/2603.03912v1Fast proton transport and neutron production in proton therapy using Fourier neural operators2026-03-04T10:19:29ZObjective: Real-time adaptive proton range verification systems based on produced neutrons require accurate information on their non-isotropic momentum distributions within short times, for which Monte Carlo (MC) methods are too computationally expensive. We present a surrogate model based on Fourier Neural Operators (FNO) for fast prediction of angle- and energy-resolved proton transport and neutron production within proton therapy.
Approach: We treat the irradiated phantom and the proton beam's state as depth-evolving series, respectively of different materials, and of spatial, angular and energy phase space density distributions. The task is solved auto-regressively by learning changes in the distributions of protons and those of produced neutrons. For training and evaluation, two datasets of 47 MC simulations featuring different primary intensities were produced. Simulated geometries were extracted from a thoracic CT scan as series of laterally homogeneous materials.
Main Results: An average relative $L^2$ discrepancy of 0.067 and 0.137 was achieved by the predicted proton and neutron distributions, respectively. This corresponded to an average gamma passing rate in the spatial distributions of 99.95$\%$ and 99.40$\%$. Training with higher primary intensities led to improvements between 12$\%$ and 30$\%$ in density metrics. Inference over depths of 40 cm at a resolution of 0.5 mm required on average 23.17 s per beam.
Significance: The proposed proton beam surrogate generates accurate spatial and momentum distributions of neutrons at MC-level accuracy within seconds, while demonstrating robust generalization with respect to irradiated geometry and beam characteristics. This approach can be used for prototyping and operation of range verification systems, other tasks such as neutron dose estimation, and can be extended to include other kinds of secondary emissions.2026-03-04T10:19:29Z25 pages, 12 figures. When specified, figures can be visualized as video using suitable PDF readersFrancesco BlangiardiFraunhofer ENASTechnical University ChemnitzHunter N. RatliffWestern Norway University of Applied SciencesFabian TeichertFraunhofer ENASTechnical University ChemnitzKristian Smeland Ytre-HaugeUniversity of BergenJan LangerFraunhofer ENASIlker MericWestern Norway University of Applied Scienceshttp://arxiv.org/abs/2603.03832v1Non-Invasive Reconstruction of Cardiac Activation Dynamics Using Physics-Informed Neural Networks2026-03-04T08:33:16ZCardiac arrhythmogenesis is governed by complex electromechanical interactions that are not directly observable in vivo, motivating the development of non-invasive computational approaches for reconstructing three-dimensional activation dynamics. We present a physics-informed neural network framework for recovering cardiac activation patterns, active tension propagation, deformation fields, and hydrostatic pressure from measurable deformation data in simplified left ventricular geometries. Our approach integrates nonlinear anisotropic constitutive modeling, heterogeneous fiber orientation, weak formulations of the governing mechanics, and finite-element-based loss functions to embed physical constraints directly into training.
We demonstrate that the proposed framework accurately reconstructs spatiotemporal activation dynamics under varying levels of measurement noise and reduced spatial resolution, while preserving global propagation patterns and activation timing. By coupling mechanistic modeling with data-driven inference, this method establishes a pathway toward patient-specific, non-invasive reconstruction of cardiac activation, with potential applications in digital phenotyping and computational support for arrhythmia assessment.2026-03-04T08:33:16ZNathan DermulHans Dierckxhttp://arxiv.org/abs/2602.11497v2End-to-End Differentiable Photon Counting CT2026-03-02T19:55:42ZQuantitative imaging is an important feature of spectral X-ray and CT systems, especially photon-counting CT (PCCT) imaging systems, which is achieved through material decomposition (MD) using spectral measurements. In this work, we present a novel framework that makes the PCCT imaging chain end-to-end differentiable (differentiable PCCT), with which we can leverage quantitative information in the image domain to enable cross-domain learning and optimization for upstream models. Specifically, the material decomposition from maximum-likelihood estimation (MLE) was made differentiable based on the Implicit Function Theorem and inserted as a layer into the imaging chain for end-to-end optimization. This framework allows for an automatic and adaptive solution of a wide range of imaging tasks, ultimately achieving quantitative imaging through computation rather than manual intervention. The end-to-end training mechanism effectively avoids the need for direct-domain training or supervision from intermediate references as models are trained using quantitative images. We demonstrate its applicability in two representative tasks: correcting detector energy bin drift and training an object scatter correction network using cross-domain reference from quantitative material images.2026-02-12T02:46:01ZSen WangYirong YangJooho LeeGrant M. StevensAdam S. Wanghttp://arxiv.org/abs/2602.16991v2Radiological mapping and uncertainty quantification by a fast Microcanonical Langevin Monte Carlo sampler2026-03-02T19:01:19ZRadiological mapping plays a critical role in nuclear emergency response and environmental management activities. A radiation image, representing the spatial and intensity distribution of the radioactivity, is reconstructed from the radiation data and the associated contextual information. Typical image reconstruction methods, such as Maximum Likelihood Expectation-Maximization (ML-EM), only provide point estimates of the pixel or voxel activities without associated uncertainties. Here, we apply a new Microcanonical Langevin Monte Carlo (MCLMC) sampler for radiation image reconstruction and uncertainty quantification. The MCLMC sampler properties are first tested with synthetic radiation images. Methods to obtain the radiation distribution estimate and the associated uncertainty from the samples drawn by MCLMC are discussed. Given sufficient measurement statistics, the radiation distribution estimate obtained from MCLMC results closely resembles the ground truth with less risk of over- or under-fitting compared to ML-EM. When MCLMC is run in parallel on a GPU, the samples can converge to the posterior distribution in about 10 seconds for an image with $10^3$--$10^4$ pixels, which is significantly faster than other comparable Markov Chain Monte Carlo (MCMC) samplers. We also tested MCLMC on a dataset from a real distributed source radiological mapping campaign, and the reconstructed results agree well with ground truth. The fast MCLMC sampler therefore enables improved imaging accuracy and prompt uncertainty quantification for reconstructed radiation images, which can better inform decision-making in response to radiological events.2026-02-19T01:30:44Z14 pages, 15 figures, 3 tablesLei PanJaewon LeeBrian J. QuiterJakob RobnikUroš SeljakJayson R. Vavrekhttp://arxiv.org/abs/2603.01969v1Assessing Hemodynamic Impact of Tissue-Engineered Vascular Graft Displacement: Combining Postoperative in vivo Results and Computational Modeling to Improve Surgical Planning2026-03-02T15:20:40ZTissue-engineered vascular grafts (TEVG) have shown promise in advancing vascular reconstructions. However, precise in vivo implantation is challenging, and it is unclear how deviations in location and size affect hemodynamics. This study aims to compare preoperative designs and postoperative anatomies of TEVG in an in vivo study to evaluate discrepancies and investigate the impact of graft displacement and size on hemodynamics by virtually simulating implantation scenarios that are informed by in vivo postoperative results. Designed and postoperative geometries of four porcine aortas were compared to measure the mismatch in implantation location and graft shape. These results informed a virtual TEVG implantation study. TEVG location, orientation, and size were varied to investigate the effects on the final aorta shape and hemodynamics. Anastomosis of TEVG was simulated using finite element modeling. Key hemodynamic metrics were obtained from virtual implantations and actual postoperative anatomies using computational fluid dynamics. Our in vivo study showed that TEVGs can experience up to 6.9 mm displacement and a 38 degree rotational shift post-implantation, leading to discrepancies in pressure drop (2.5 mmHg, 50%) and time-averaged wall shear stress (7.2 Pa, 72%) compared to predictions. Virtual anastomosis simulations improved aortic shape predictions by 27.5%. Our results highlight the sensitivity of key hemodynamic metrics to graft implantation location and size mismatch. By quantifying displacement ranges and their impacts during surgery, surgeons can make informed decisions.2026-03-02T15:20:40ZSeda AslanEnze ChenMiya Mese-JonesJacqueline ContentoHidenori HayashiKeigo KawajiJoey HuddleJed JohnsonYue-Hin LokeMark FugeLaura OlivieriThao D NguyenNarutoshi HibinoAxel Kriegerhttp://arxiv.org/abs/2512.14525v2Charge collection efficiency of thimble ionization chambers exposed to ultra-high dose per pulse2026-03-02T14:16:52ZBackground: Commercially available ionization chambers (ICs) exposed to ultra-high dose per pulse (UHDP) exhibit deviations from a linear dose response due to volume recombination. Simulation models have been developed to describe the charge collection efficiency (CCE) but focused on parallel-plate ICs. This study aims to measure and simulate the CCE and polarity effect of thimble ICs in UHDP. Methods: The response of two PinPoint3D T31022 (PP3D) and two PinPoint T31023 (PP) ICs was investigated experimentally at the national metrology institute of Germany (PTB). The ICs were irradiated using the UHDP reference electron beam with dose per pulse up to 9.3 Gy for different voltages. A novel finite element code capable of simulating 1D and 2D geometries was developed. Results: Thimble ICs exhibit a pronounced polarization effect when irradiated with UHDP. When the sign of the collected charge is negative, the CCE is larger than when it is positive. The major contribution to the polarity effect can be attributed to the polarity-dependent charge transport and recombination. Experimental and simulated CCE (polarity effect correction factor) agrees within 1.4 % (7.0 %) and 1.6 % (3.2 %) for the PP3D and PP ICs, respectively. The CCE of parallel-plate and thimble ICs is related through a geometrical rule. Conclusions: The PP IC shows greater CCE due to its smaller external radius. The numerical model is able to satisfactory reproduce the actual CCE and polarity effect for these two chambers. At UHDP, thimble ICs should be used with caution due to their large polarity effect.2025-12-16T15:59:10ZJosé Paz-MartínAndreas SchüllerMarvin ApelAraceli Gago-AriasJuan Pardo-MonteroFaustino Gómez