https://arxiv.org/api/zJynSlZVn2wB4eiZmwQ5HA2bH042026-09-10T22:27:57Z92007515http://arxiv.org/abs/2509.04024v3Cine MRI-Validated Biventricular Electromechanical Digital Twin Framework for Predicting Regional Endocardial Motion2026-08-18T21:15:04ZPersonalized cardiovascular medicine increasingly relies on digital twin frameworks to translate clinical imaging into patient-specific functional insights. This work presents a biventricular electromechanical human heart model for predicting regional endocardial motion. The model integrates realistic 3D cardiac geometry, rule-based myocardial fiber orientation, reaction-diffusion electrophysiology, voltage-dependent active stress, closed-loop systemic and pulmonary hemodynamics, and two-way fluid-structure interaction with explicit 3D blood domains. Mechanical boundary conditions are also introduced to represent the influence of surrounding tissues on cardiac motion. The model was validated against Cine magnetic resonance imaging (MRI)-derived right ventricular motion, demonstrating consistent regional motion patterns between simulation and imaging results. The validated framework enables quantitative assessment of regional endocardial displacement and velocity, supporting the identification of mechanically favorable implantation regions for motion-driven intracardiac devices. The results further highlight that implantation-site selection should consider not only local motion amplitude, but also anatomical safety and electrophysiological suitability. Overall, the proposed Cine MRI-validated electromechanical digital twin framework provides a predictive platform for regional endocardial motion analysis and establishes a foundation for future patient-specific planning of self-powered intracardiac implants prior to clinical implementation.2025-09-04T08:55:02ZMilad HasaniTomas ZarembaSam RiahiAlireza Rezaniahttp://arxiv.org/abs/2608.18252v1Angle-domain null subtraction imaging from beamformed plane-wave data2026-08-18T19:04:06ZNull subtraction imaging (NSI) narrows the apparent lateral response by combining fields produced with a zero-mean apodization and two DC-offset variants. Conventional NSI applies these weights across receive elements and therefore requires access to channel data and flexible beamformers, while increasing the computation time. We investigate an angle-domain analogue, termed angular NSI, that instead operates on the per-angle images produced during coherent plane-wave compounding. A matrix formulation was used to distinguish receive-domain and angle-domain null subtraction expressions and to identify their independent computational components. The method was evaluated using a simulated point target, an open microbubble (MB) traces dataset and two in vivo carotid acquisitions. Angle sampling, noise, phase jitter and target position were swept in simulation. A synchronized GPU benchmark compared the complete reconstructions. Conventional receive-domain NSI and standard delay-and-sum (DAS) imaging were references. Angle-domain NSI reduced the simulated -6dB lateral width from 0.226 mm for DAS to 0.116 mm, compared to 0.009mm for conventional receive-domain NSI, while the axial width was 0.721 mm for all methods. Median reconstruction times on an RTX A2000 GPU were 23.92, 30.19 and 24.74 ms for DAS, conventional NSI and angle-domain NSI. In power Doppler, the apparent width of the MB traces were reduced by 50.2% for conventional NSI and 30.9% for angular NSI compared to DAS. In vivo, both NSI variants reduced generalized contrast-to-noise ratio relative to DAS. Angle-domain NSI can be simply implemented as a post-processing step for all plane-wave sequences after beamforming. The technique is compatible with most of the usual beamformer implementations. It effectively reduces apparent lateral width, and its computation time is close to DAS and faster than conventional NSI.2026-08-18T19:04:06ZHenri Leroyhttp://arxiv.org/abs/2608.18036v1Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors2026-08-18T17:31:07ZMRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.2026-08-18T17:31:07ZMahdi SaberiYaşar Utku AlçalarMerve GülleChetan ShenoyMehmet Akçakayahttp://arxiv.org/abs/2608.17974v1Flexible Piezoresistive Yarn Pressure Sensor for Arterial Blood Pressure Waveform Measurement2026-08-18T16:26:51ZThe arterial blood pressure (ABP) waveform contains essential information concerning the hemodynamic status and its relation to the diagnosis of cardiovascular conditions. Therefore, the continuous monitoring of the ABP waveform has become important. A measurement system that offers a non-invasive approach and high accuracy in detecting morphological details of the ABP waveform is needed. In this study, we introduce a flexible piezoresistive yarn (FPY) pressure sensor for continuous non-invasive ABP waveform measurement. The sensor was experimentally validated using two scenarios: measurements on a hardware simulator and at an arterial site. The simulator measurement aimed to assess the sensor's performance in detecting consistent waveforms, while the arterial site measurements evaluated the sensor's performance in measuring ABP waveforms corresponding to the cardiovascular cycle. The simulator measurement results showed high repeatability, reproducibility, and accuracy relative to the reference signal at the upper limit of realistic force magnitude, as measured by the correlation metric: 0.9999 $\pm$ 0.0002, 0.9994 $\pm$ 0.0002, and 0.9731 $\pm$ 0.0027, respectively. The correlation value derived from measurements at the arterial site compared with measurements using a 3D force sensor as a reference sensor was 0.9880 $\pm$ 0.0035. Based on our results, the FPY pressure sensor can be used as an innovative solution for monitoring ABP waveforms and has further potential to be developed as a diagnostic device for evaluating cardiovascular conditions.2026-08-18T16:26:51Z17 pages, 12 figures; Preprint to be submitted to MDPI BiosensorsRizal MaulanaÁdám RákSándor FöldiGyörgy Csereyhttp://arxiv.org/abs/2608.17357v1LV-CARE-Diff: A Conditional Anatomy-Aware Diffusion Model for Left Ventricular Shape Reconstruction and Function Quantification from Ultra-Sparse Cine Slices2026-08-18T04:24:49ZLeft ventricular functional quantification is an essential examination and is routinely performed using cardiovascular magnetic resonance (CMR) cine imaging. However, conventional CMR cine protocols require the acquisition of multiple short-axis (SAX) slices to cover the entire left ventricle (LV) along with two long-axis (LAX) slices, which is time-consuming and places a considerable burden on patients who are unable to sustain repeated breath-holds, limiting its suitability for large-scale early screening. In this study, a Conditional Anatomy-Aware Diffusion Model (LV-CARE-Diff) was developed using a coarse-to-fine strategy to reconstruct the complete LV shape from ultra-sparse cine slices, namely three short-axis and two long-axis slices, with the aim of accelerating CMR cine examination. LV-CARE-Diff employs a 3DUNet to generate a coarse initial shape, which is subsequently refined through a residual diffusion model. A condition-guided input incorporating imaging plane orientation and positional metadata was constructed to enable spatial awareness, and a multi-objective training strategy jointly supervising shape, function, and anatomy was incorporated to guide high-fidelity reconstruction. LV-CARE-Diff was compared against a standalone 3DUNet, a standalone diffusion model, and a 3D UNet with diffusion-based refinement. Testing results indicated that complete LV shape could be robustly reconstructed by all deep learning models, with the highest reconstruction performance achieved by the proposed LV-CARE-Diff. Deep learning models reconstructing LV shape from sparse cine slices preserved 96% of functional quantification accuracy while reducing imaging time by 73%. The LV-CARE-Diff framework established in this study enables ultra-sparse cine acquisition to shorten CMR examination duration without sacrificing quantitative functional accuracy.2026-08-18T04:24:49Z55 pages, 11 main-text figures, 2 main-text tables; supplementary material includedXinwang LiYu LianBowei LiuYifei JiangJingjing XiaoHaiyan DingXiangchuang KongRui Guohttp://arxiv.org/abs/2607.16491v2Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction2026-08-17T11:20:53ZHigh-resolution three-dimensional (3-D) medical diffusion models remain constrained by the cost of processing full volumes, even when denoising is performed in a compact latent space. We introduce a continuous 3-D latent diffusion model (LDM) framework for computed tomography (CT) and magnetic resonance imaging (MRI) generation and measurement-guided reconstruction. Its central component is a compact autoencoder (AE) with a coordinate-conditioned local implicit image function (LIIF) decoder that represents a volume as a continuous function of spatial coordinates. By evaluating the convolutional decoder once on the latent grid and restricting repeated computation to a lightweight implicit head, the proposed design avoids overlapping sub-volume decoding while remaining differentiable for inverse-problem optimization. We evaluate the framework on CT volumes of 512^3 voxels and MRI volumes of 256^3 voxels. On high-resolution CT, the proposed AE is approximately x12-32 faster than the evaluated reference autoencoders, achieves the lowest peak graphics processing unit (GPU) memory use, and retains comparable structural fidelity despite a moderate reduction in voxel-level accuracy. The resulting frozen 3-D latent prior generates coherent full volumes without visible patch seams and can be applied, without task-specific retraining, to sparse-view CT and accelerated MRI reconstruction through hard data consistency. Although direct pixel-domain reconstruction remains more accurate, the results demonstrate that a single volumetric latent prior can support both unconditional generation and measurement-conditioned reconstruction on one GPU. Overall, the framework provides a practical trade-off between continuous volumetric decoding, computational efficiency, and fine-detail preservation. Our code will be made available at https://github.com/mellak/.2026-07-17T20:32:13Z14 pages, 7 figures, 3 tablesYouness MellakAntoine De PaepeDimitris VisvikisAlexandre Boussehttp://arxiv.org/abs/2602.13913v3Early warning indicators of spatial epidemics from gauge mediated contagion: a statistical mechanics approach applied to COVID19 in Germany2026-08-16T19:29:51ZWe develop a statistical mechanics model for spatially extended epidemic dynamics in which contagion is mediated by an explicit environmental field rather than by instantaneous local contact. Building on the Doi Peliti formalism, we construct a stochastic field theory for susceptible and infected hosts coupled to a diffusive pathogen field and integrate out the mediator to obtain a non local effective action with a Yukawa type interaction kernel in space and memory effects in time. This formalism yields closed analytical expressions for the basic and effective reproduction numbers, including one loop fluctuation corrections that renormalize the transmission rate and generate spatial shielding effects beyond mean field SIR models. We derive an effective screening mass and a Debye like correlation length whose critical softening signals an impending instability of the disease free state, providing a field theoretical early warning indicator for epidemic waves. Superspreading is incorporated through a heterogeneous ``epidemic charge`` distribution, which controls the divergence of the correlation length and explains the emergence of multifocal outbreak patterns even when the population average $R_0$ is subcritical. Finally, we apply the model to high resolution COVID19 incidence data across $\approx 400$ German districts, dynamically extracting the effective screening mass and the renormalized reproduction number, and show that the gauge mediated indicators anticipate major changes in epidemic regime several days before classical SIR based estimates.2026-02-14T22:31:57Z23 pages, 8 figures,PHYSA, 2026, 131940Jose de Jesus Bernal-AlvaradoDavid Delepine10.1016/j.physa.2026.131940http://arxiv.org/abs/2606.13485v4Interaction Dynamics MPC for Knee Rehabilitation Exoskeletons: A Closed-Loop SEA Outer-Loop Study2026-08-16T17:15:42ZSafe rehabilitation is an interaction-dynamics problem: the controller must regulate a prescribed motion while absorbing involuntary spasm, voluntary effort, actuator compliance, and model mismatch as disturbances. This paper instantiates the predictive interaction-dynamics framework of the base pHRI formulation on a SEA knee joint. SEA feedforward reduces the gravity-compensated knee to the same scalar double integrator as the base framework, while a dynamic-residual measurement from spring deflection supplies an interaction-disturbance observation. A steady-state target converts the estimated disturbance into a cancelling input, and a finite-horizon quadratic program regulates deviations from that target under range-of-motion, torque, and velocity constraints. The evaluation matches stiffness and damping across controllers so gains cannot be attributed to higher impedance. Under a motion-opposing $15\unit{Nm}$ step, classical impedance and MPC without estimation produce about $500\unit{mrad}$ steady-state error, whereas Kalman-augmented interaction MPC reduces this to $1.17\unit{mrad}$ at 100~Hz and $0.70\unit{mrad}$ at 500~Hz; the 500~Hz peak is $7.27\unit{mrad}$. In 30 randomized trials, the 95th-percentile peak is $21.57\unit{mrad}$. Bounded Assist-as-Needed scheduling, a corrective-channel energy tank, constrained OSQP stress cases, direct MuJoCo execution, and a posture-clamped MyoSuite knee slice are implemented. The framework holds on a single-mass, closed-inner-loop SEA approximation; an explicit two-mass plant with a finite-bandwidth, pole-placed inner torque loop (Section~VIII) confirms this for nominal tracking but shows delivered torque can overshoot the commanded bound by 21.7\% near saturation. Scope excludes clinical intent recognition, full-system passivity, safety certification, hardware trials, and multi-joint validation.2026-06-11T15:35:03ZYongyan CaoJinshan Tanghttp://arxiv.org/abs/2608.08860v2Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue2026-08-16T17:11:28ZFlexible neural electrode threads must be placed at a prescribed depth while the cortical surface moves with cardiac and respiratory pulsation. A controller tracking a fixed point in the laboratory frame cannot distinguish commanded insertion from tissue motion; the error appears as both a depth offset and relative tip--tissue velocity during contact. This paper formulates thread insertion in tissue-relative coordinates: a harmonic observer predicts delayed cortical-surface motion over the control horizon, a constrained MPC regulates the tip relative to that prediction while limiting actuator effort and lateral relative velocity, and an augmented disturbance state removes the steady offset from persistent contact force and model mismatch. In a 1-DOF MuJoCo benchmark, the controller reaches RMS relative-placement errors of 12.0\um\ free-space and 1.9\um\ in contact, versus 18.3/176.8\um\ for delayed-feedback impedance and 286.1/275.5\um\ for laboratory-frame PD -- the lower contact offset costs more peak contact force (3.43 vs.\ 2.00~mN), since it drives to commanded depth rather than yielding to tissue. A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50~mm/s at 2.1\um\ lateral placement error, and a feasibility-restoring soft-slack formulation keeps the shear constraint solvable under degraded sensing where a matched hard-constraint controller fails. A two-vertex Lyapunov certificate for the finite-horizon gain holds over $-40\%/{+}50\%$ reflected-mass mismatch, and the 1-DOF QP solves in under 0.4~ms at the 95th percentile. These results are a simulation-based control benchmark, not a clinical safety claim: the modeled tip is a rigid contact point, and flexible-thread mechanics, a validated force constraint, biological damage thresholds, and hardware-realistic sensing and timing remain necessary before deployment.2026-08-09T18:53:32ZYongyan CaoXiaobo Lihttp://arxiv.org/abs/2608.15677v1Low-rank modal endpoints from beat-resolved retinal arterial Doppler holography velocity waveforms characterize the response to flicker provocation2026-08-16T11:03:16ZConventional retinal flicker endpoints quantify changes in diameter, mean velocity, or flow but do not capture the modal concentration of the cardiac velocity waveform during neurovascular stimulation. Here, beat-resolved retinal Doppler holography and low-rank modal decomposition are combined to derive compact arterial endpoints from unfiltered arterial segment-velocity waveforms sampled across beats and vessel locations. For each acquisition, locally centered waveforms are assembled into a common matrix and decomposed by singular-value decomposition (SVD). Robust summaries quantify total pulsatile scale, modal amplitude, residual amplitude, mean-to-pulsatile balance, and singular-spectrum dimensionality; the same construction can also be applied descriptively to individual beats. We demonstrate the framework using 33 temporally ordered Baseline~1/Flicker/Baseline~2 acquisitions from one eye. Relative to the pooled baselines, 13-Hz flicker was associated with lower centered-waveform RMS scale $R_0$ and leading-mode amplitude $A_1$, and with higher robust residual-amplitude ratios $ρ_1$ and $ρ_2$, mean-to-pulsatile ratio MPR, effective rank, and participation ratio; these contrasts showed exploratory within-session separation after Holm adjustment. No evidence of differences in the absolute residual amplitudes $R_1$ and $R_2$ was detected; together, these observations are consistent with reduced concentration in the leading acquisition-specific arterial pulse mode rather than an increase in absolute residual pulsatility.2026-08-16T11:03:16ZSienna O'SheaMaxime Boy ArnouldAdrien GordonYann FischerZacharie AurayMichael Atlanhttp://arxiv.org/abs/2608.15368v1Proposal of a consistent value for the mean excitation energy of liquid water using advanced modeling, detailed simulations and precission proton Bragg curves2026-08-15T18:43:26ZProtontherapy precision depends on accurately knowing the stopping power of liquid water, as it is the most abundant component of soft body tissues. Difficulties when working with volatile liquids have led to a long-standing debate regarding the values of the stopping power and the mean excitation energy $I$ of liquid water. The equivalence between the stopping power of liquid water and amorphous ice per unit mass density across all clinically relevant proton energies opens the possibility to obtain a reliable estimation of the $I$-value of liquid water. In this work, we employ two complementary theoretical methodologies to assess the proton stopping power of water. The MELF-GOS (Mermin Energy Loss Function - Generalized Oscillator Strengths) approach, based on the perturbative dielectric formalism, serves as an accurate reference for sufficiently high energies, while the novel non-perturbative TDDFT-Penn (time-dependent density functional theory - Penn) method ensures accuracy for energies even below the stopping maximum. These stopping-power values were incorporated into the simulation code SEICS (Simulation of Energetic Ions and Clusters through Solids) to evaluate proton Bragg curves from $1$ to $230$ MeV. Comparisons with available precise depth-dose measurements provide critical insights that help establish the consistent value $I = 79.4$ eV for liquid water, providing robust physical grounds for improving range prediction for treatment planning.2026-08-15T18:43:26Z12 pages, 4 figuresPablo de VeraIsabel AbrilFlávio MatiasJulian M. B. ShortoHélio YoriyazRafael Garcia-Molinahttp://arxiv.org/abs/2608.15350v1Whole Blood-Based Point-of-Care Assay for Single-Tier Lyme Disease Testing2026-08-15T18:08:42ZRapid point-of-care diagnostics that operate directly on whole blood can accelerate clinical decision-making by bypassing complex sample preprocessing and centralized laboratory infrastructure. However, most serologic assays still require serum or plasma, limiting near-patient deployment. This challenge is particularly evident for Lyme disease, whose diagnosis relies on centralized two-tier serology. Here, we present a whole-blood multiplexed vertical flow assay (WB-xVFA) that performs single-tier Lyme serology directly from 50 microliter of whole blood. The assay combines multilayer blood filtration with a peptide-patterned nitrocellulose membrane to separate cellular components and detect Lyme-associated IgM/IgG responses on a cartridge. Coupled with smartphone-based imaging and machine-learning analysis, the WB-xVFA provides results in 20 min. The assay remained robust across hematocrits up to 60% and sample volumes ranging from 25 to 100 microliter. In blinded testing of 62 whole-blood measurements, it achieved ~97% sensitivity and specificity, demonstrating the feasibility of rapid, near-patient whole-blood Lyme serology.2026-08-15T18:08:42Z26 pages, 4 figuresMihye LeeRajesh GhoshArtem GoncharovRui-Chian TangBarath PalanisamyGyeo-Re HanAdrian AnayaElizabeth J. HornPaul M. ArnaboldiRaymond J. DattwylerOmai B. GarnerAydogan OzcanDino Di Carlohttp://arxiv.org/abs/2608.15272v1Relative and absolute dosimetric commissioning of the ELIMAIA--ELIMED laser-driven proton beamline at 23.45 MeV2026-08-15T15:15:33ZThe development of laser-driven proton beamlines for biomedical and radiobiological applications requires traceable dosimetry and reliable online monitoring at the irradiation point. In this work, we report the relative and absolute dosimetric commissioning of the ELIMAIA--ELIMED laser-driven proton beamline at ELI Beamlines using an energy-selected proton beam with an average energy of about 24~MeV. Radiochromic-film measurements were used to characterize the transverse dose distribution, the depth--dose profile, and the proton energy spectrum at the irradiation point. The reconstructed spectrum was centred at $23.45~\mathrm{MeV}$ with a FWHM of $2.60~\mathrm{MeV}$, while the transverse dose distribution showed an approximately $5.5~\mathrm{mm}$ field size with a millimetre-scale homogeneous region. The Faraday Cup was used as the absolute reference detector for dose to water determination and for cross-calibrating the Dual-Gap Ionization Chamber, which was operated as the primary online dose monitor. The Integrating Current Transformer and Secondary Electron Monitor were evaluated as upstream relative beam monitors. An independent RCF--FC dose comparison performed over fifty consecutive shots yielded $30.45 \pm 3.5~\mathrm{cGy}$ from the FC and $36.46 \pm 1.8~\mathrm{cGy}$ from the EBT3 film. Dedicated G4ELIMED Monte Carlo simulations showed that the RCF positioned upstream of the FC perturbs the FC measurement through proton losses outside the FC acceptance and through an increase in the effective beam area at the FC entrance. Applying the resulting correction factor, $C_{\mathrm{MC}}=1.109$, reduced the residual difference between the FC- and RCF-derived doses to about $7\%$. These results establish the dosimetric chain of the ELIMAIA--ELIMED beamline under the present low-fluence commissioning conditions and identify the operational limits of the online monitoring system.2026-08-15T15:15:33ZG. A. P. CirroneG. PetringaA. KurmanovaR. CatalanoA. AmatoA. PappalardoM. G. GuarreraF. SchillaciP. BlahaF. GreplM. TryusA. VelyhanL. GiuffridaD. MargaroneG. Cuttonehttp://arxiv.org/abs/2602.19264v2A novel method for analysis of transient morphological changes in quasiperiodic physiological signals and their neurogenic correlates2026-08-14T18:19:54ZConventional ECG visualization and analysis methods typically emphasize either waveform morphology or rhythm variability. This work presents a visualization framework for quasiperiodic physiological signals that enables simultaneous assessment of beat-to-beat morphological changes and rhythm dynamics in a single representation.
The proposed method converts quasiperiodic signals into two-dimensional carpet plots. Characteristic events (e.g., ECG R peaks) are used to align consecutive signal segments, which are transformed into color-coded rows and stacked in chronological order. The resulting image preserves both the temporal evolution of signal morphology and variations in cycle duration. The method was evaluated using ECG recordings from multiple publicly available databases containing healthy subjects and patients with diverse cardiac abnormalities, as well as synchronized multimodal physiological recordings.
Carpet plots enabled rapid visualization of transient morphological changes alongside heart rate dynamics across recordings ranging from several minutes to hours. The representation highlighted clinically relevant phenomena, including ST segment alterations, QT interval variability, changes in T wave morphology, atrial fibrillation episodes, premature ventricular complexes, Wenckebach periodicity, and stress-test phase transitions. The image-based representation was also shown to be suitable for automated analysis using convolutional neural network feature extraction.
Carpet plots provide a compact representation of quasiperiodic physiological signals, jointly visualizing rhythm and morphology across long-term recordings. The proposed framework facilitates both expert interpretation and image-based computational analysis, offering a general approach for investigating transient physiological phenomena in ECG and other synchronized quasiperiodic signals.2026-02-22T16:26:53Z31 pages, 7 figuresTomasz GradowskiDamian WalągTomir DomańskiTeodor Buchner10.1016/j.cmpb.2026.109611http://arxiv.org/abs/2608.14422v1UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI2026-08-14T16:04:46ZMRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net2026-08-14T16:04:46ZIEEE International Workshop on Machine Learning for Signal Processing (MLSP)Mahdi SaberiToygan KiliçMehmet Akçakaya