https://arxiv.org/api/anqlSJ0ZsTBJ4WS3LmcfBh7Pnow 2026-06-24T09:43:16Z 9001 735 15 http://arxiv.org/abs/2511.08812v1 Per-Lesion Radiomics Analysis of 68Ga-DOTA FAPI-46 and 18F-FDG PET/CT in Non-Small Cell Lung Cancer: A pilot Study 2025-11-11T22:26:56Z This pilot study compares per-lesion radiomics features of [68Ga]-DOTA FAPI-46 and [18F]-FDG PET/CT in non-small cell lung cancer (NSCLC) to explore complementary insights into intratumoral heterogeneity beyond conventional SUV metrics, aiming to enhance lesion characterization and clinical decision-making. A total of 28 PET/CT scans (14 [18F]-FDG and 14 [68Ga]-DOTA FAPI-46) were acquired for the initial staging of biopsy-confirmed NSCLC. A total of 81 co-localized lesions (lung: 21, mediastinal lymph nodes: 42, bone: 18) were segmented, with radiomics features extracted via PyRadiomics after IBSI-compliant preprocessing. Paired per-lesion comparisons used t-tests or Wilcoxon signed-rank tests with Benjamini-Hochberg FDR correction. Significant differences (adjusted P < 0.05) were identified across intensity, texture, and shape features. In lung lesions, FAPI showed lower first-order metrics but higher variance and GLCM contrast, suggesting stromal heterogeneity. Mediastinal lymph nodes had fewer differences, with FAPI exhibiting lower run percentage (GLRLM: -0.298, -6.196, P=1.45E-08). Bone lesions showed extensive variations, including reduced FAPI entropy (e.g., Entropy: -1.743, -5.798, P=6.95E-08). Feature overlaps highlighted complementary stromal (FAPI) and metabolic (FDG) insights. This pilot study demonstrates that per-lesion radiomics can capture complementary biological information from FAPI and FDG PET in NSCLC, highlighting intratumoral heterogeneity and stromal activity not fully appreciated by conventional SUV-based metrics. 2025-11-11T22:26:56Z Setareh Hasanabadi Maryam Cheraghi Hossein Behnam Manesh Mohadeseh Bayat Mehrdad Bakhshayesh Karam Andrea Corsi Yazdan Salimi Mohammad Saber Azimi Abtin Doroudinia Arezu Karami Hossein Arabi http://arxiv.org/abs/2511.08745v1 Patient-Scale Blood Flow Analysis in Artery Stent Implantation via Smoothed-Particle Hydrodynamics 2025-11-11T20:06:01Z A unified Smoothed Particle Hydrodynamics (SPH) simulation framework for coronary stent implantation is developed, which unifies weakly compressible hemodynamics, Neo-Hookean solids, and stent-artery contacts, based on a multi-resolution particle discretization. Prior to application, feasibility and accuracy are established via three baseline validations: (i) poiseuille flow in a two-dimensional channel with prescribed parabolic inflow and a pressure outlet, maintaining parabolic profiles with low Root Mean Squared Error of Prediction (RMSEP); (ii) channel flow initialized with a uniform velocity field and driven by a specified inlet-outlet pressure differential, with agreement to reference profiles quantified by low RMSEP at five reference instants; and (iii) a three-ring impact benchmark in solid mechanics, capturing large deformation, multi-body contact, and self-contact. The validated framework is subsequently applied to a coronary bifurcation with a focal stenosis, where flow-field diagnostics reveal acceleration at the stenotic throat, near-wall low-velocity zones, and co-localization of elevated pressure with increased Von Mises stress at the bifurcation and inlet. Following simulated stent implantation, velocity transitions across the stenosis become smoother, pressure gradients are reduced, and the fractional flow reserve increases from 0.45 to 0.91. These results demonstrate that the proposed SPH framework yields quantitatively reliable, clinically interpretable hemodynamic metrics alongside robust solid-solid contact predictions, thereby supporting rigorous analysis and pre-procedural planning of vascular interventions. 2025-11-11T20:06:01Z Jinlei Zhou Sukang Peng Yongchuan Yu Dong Wu Xiangyu Hu http://arxiv.org/abs/2506.19600v3 Filling of incomplete sinograms from sparse PET detector configurations using a residual U-Net 2025-11-11T13:28:59Z Long axial field-of-view PET scanners offer increased field-of-view and sensitivity compared to traditional PET scanners. However, a significant cost is associated with the densely packed photodetectors required for the extended-coverage systems, limiting clinical utilisation. To mitigate the cost limitations, alternative sparse system configurations have been proposed, allowing an extended field-of-view PET design with detector costs similar to a standard PET system, albeit at the expense of image quality. In this work, we propose a deep sinogram restoration network to fill in the missing sinogram data. Our method utilises a modified Residual U-Net, trained on clinical PET scans from a GE Signa PET/MR, simulating the removal of 50% of the detectors in a chessboard pattern (retaining only 25% of all lines of response). The model successfully recovers missing counts, with a mean absolute error below two events per pixel, outperforming 2D interpolation in both sinogram and reconstructed image domain. Notably, the predicted sinograms exhibit a smoothing effect, leading to reconstructed images lacking sharpness in finer details. Despite these limitations, the model demonstrates a substantial capacity for compensating for the undersampling caused by the sparse detector configuration. This proof-of-concept study suggests that sparse detector configurations, combined with deep learning techniques, offer a viable alternative to conventional PET scanner designs. This approach supports the development of cost-effective, total body PET scanners, allowing a significant step forward in medical imaging technology. 2025-06-24T13:10:44Z 18 pages, 11 figures Klara Leffler Luigi Tommaso Luppino Samuel Kuttner Karin Söderkvist Jan Axelsson http://arxiv.org/abs/2511.07705v1 Mechanistic multiphysics modeling reveals how blood pulsation drives CSF flow, pressure, and brain deformation under physiological and injection conditions 2025-11-11T00:02:49Z Intrathecal (IT) injection is an effective way to deliver drugs to the brain bypassing the blood-brain barrier. To evaluate and optimize IT drug delivery, it is necessary to understand the cerebrospinal fluid (CSF) dynamics in the central nervous system (CNS). In combination with experimental measurements, computational modeling plays an important role in reconstructing CSF flow in the CNS. Existing models have provided valuable insights into the CSF dynamics; however, most neglect the effects of tissue mechanics, focus on partial geometries, or rely on measured CSF flow rates under specific conditions, leaving full-CNS CSF flow field predictions across different physiological states underexplored. Here, we propose a comprehensive multiphysics computational model of the CNS with three key features: (1) it is implemented on a fully closed geometry of CNS; (2) it includes the interaction between CSF and poroelastic tissue as well as the compliant spinal dura mater; (3) it has potential for predictive simulations because it only needs data on cardiac blood pulsation into the brain. Our simulations under physiological conditions demonstrate that our model accurately reconstructs the CSF pulsation and captures both the craniocaudal attenuation and phase shift of CSF flow along the spinal subarachnoid space (SAS). When applied to the simulation of IT drug delivery, our model successfully captures the intracranial pressure (ICP) elevation during injection and subsequent recovery after injections. The proposed multiphysics model provides a unified and extensible framework that allows parametric studies of CSF flow dynamics and optimization of IT injections, serving as a strong foundation for integration of additional physiological mechanisms. 2025-11-11T00:02:49Z 35 pages, 6 figures, 2 tables Zhuogen Li Keyu Feng Hector Gomez http://arxiv.org/abs/2511.07088v1 Validation of Fully-Automated Deep Learning-Based Fibroglandular Tissue Segmentation for Efficient and Reliable Quantitation of Background Parenchymal Enhancement in Breast MRI 2025-11-10T13:24:31Z Background parenchymal enhancement (BPE) on breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) shows potential as a breast cancer risk marker. Clinically, BPE is qualitatively assessed by radiologists, but quantitative BPE measures offer potential for more precise risk evaluation. This study evaluated an existing open-source, fully-automated deep learning-based (DL-based) method for segmenting fibroglandular tissue (FGT) to quantify BPE and compared it to a semi-automated fuzzy c-means method. Using breast MRI examinations from 100 women, we evaluated segmentation agreement, concordance across quantitative BPE metrics, and associations with qualitative BPE. The quality of FGT segmentations from both methods was scored by a radiologist. While the DL-based and semi-automated methods showed good agreement for quantitative BPE measurements, DL-based measures more strongly correlated with qualitative BPE assessments and DL-based segmentations were scored as higher quality by the radiologist. Our findings suggest that DL-based FGT segmentation enhances efficiency for objective BPE quantification and may improve standardized breast cancer risk assessment. 2025-11-10T13:24:31Z Yu-Tzu Kuo Anum S. Kazerouni Vivian Y. Park Wesley Surento Suleeporn Sujichantararat Daniel S. Hippe Habib Rahbar Savannah C. Partridge http://arxiv.org/abs/2511.06627v1 A Field Free Line 3D Reconstruction Model for Magnetic Particle Imaging for Improved Sensitivity, Resolution, and High Dynamic Range Imaging 2025-11-10T02:12:44Z Magnetic particle imaging (MPI) is a tracer-based imaging modality that detects superparamagnetic iron oxide nanoparticles in vivo, with applications in cancer cell tracking, lymph node mapping, and cell therapy monitoring. We introduce a new 3D image reconstruction framework for MPI data acquired using multi-angle field-free line (FFL) scans, demonstrating improvements in spatial resolution, quantitative accuracy, and high dynamic range performance over conventional sequential reconstruction pipelines. The framework is built by combining a physics-based FFL signal model with tomographic projection operators to form an efficient 3D forward operator, enabling the full dataset to be reconstructed jointly rather than as a series of independent 2D projections. A harmonic-domain compression step is incorporated naturally within this operator formulation, reducing memory overhead by over two orders of magnitude while preserving the structure and fidelity of the model, enabling volumetric reconstructions on standard desktop GPU hardware in only minutes. Phantom and in vivo results demonstrate substantially reduced background haze and improved visualization of low-intensity regions adjacent to bright structures, with an estimated $\sim$11$\times$ improvement in iron detection sensitivity relative to the conventional X-space CT approach. These advances enhance MPI image quality and quantitative reliability, supporting broader use of MPI in preclinical and future clinical imaging. 2025-11-10T02:12:44Z Toby Sanders Hayden Carlton Preethi Korangath Olivia C. Sehl Robert Ivkov Patrick W. Goodwill http://arxiv.org/abs/2511.06178v1 A dynamic shim approach for correcting eddy current effects in diffusion-prepared MRI acquisition using a multi-coil AC/DC shim-array 2025-11-09T01:40:20Z Purpose: We developed a dynamic B0 shimming approach using a 46-channel AC/DC shim array to correct phase errors caused by eddy currents from diffusion-encoding gradients in diffusion-prepared MRI, enabling high b-value imaging without the SNR loss from the use of magnitude stabilizer. Methods: A 46-channel AC/DC shim array and corresponding amplifier system were built. Spin echo prescans with and without diffusion preparation were then used to rapidly measure eddy current induced phase differences. These phase maps were used as targets in an optimization framework to compute compensatory shim currents for multi-shot 3D diffusion-prepared acquisitions. Results: The proposed method allows flexible use of the AC/DC shim array to correct undesirable eddy current effects in diffusion-prepared MRI. Phantom and in vivo experiments demonstrate whole-brain, cardiac-gated, multi-shot 3D diffusion-prepared imaging without the use of magnitude stabilizers. The approach enables preservation of full SNR while achieving reliable diffusion encoding at b-values up to 2000 s/mm2. Conclusions: This work demonstrates a new strategy for applying an AC/DC shim array to compensate for eddy current induced phase errors in diffusion-prepared MRI. By eliminating the need for magnitude stabilizer, it enables efficient high-quality diffusion imaging with full signal sensitivity retained. 2025-11-09T01:40:20Z 35 pages, 10 figures Magnetic Resonance in Medicine, 2026 Congyu Liao Jason P. Stockmann Zhitao Li Zhixing Wang Mengze Gao Lincoln Craven-Brightman Monika Sliwiak Charles Biggs Jack Glad Jiazheng Zhou Yurui Qian Zheng Zhong Nan Wang Hua Wu Thomas Grafendorfer Fraser Robb Bernhard Gruber Azma Mareyam Adam B. Kerr Xiaozhi Cao Kawin Setsompop 10.1002/mrm.70294 http://arxiv.org/abs/2501.09935v3 Physics-informed DeepCT: Sinogram Wavelet Decomposition Meets Masked Diffusion 2025-11-08T13:06:49Z Diffusion model shows remarkable potential on sparse-view computed tomography (SVCT) reconstruction. However, when a network is trained on a limited sample space, its generalization capability may be constrained, which degrades performance on unfamiliar data. For image generation tasks, this can lead to issues such as blurry details and inconsistencies between regions. To alleviate this problem, we propose a Sinogram-based Wavelet random decomposition And Random mask diffusion Model (SWARM) for SVCT reconstruction. Specifically, introducing a random mask strategy in the sinogram effectively expands the limited training sample space. This enables the model to learn a broader range of data distributions, enhancing its understanding and generalization of data uncertainty. In addition, applying a random training strategy to the high-frequency components of the sinogram wavelet enhances feature representation and improves the ability to capture details in different frequency bands, thereby improving performance and robustness. Two-stage iterative reconstruction method is adopted to ensure the global consistency of the reconstructed image while refining its details. Experimental results demonstrate that SWARM outperforms competing approaches in both quantitative and qualitative performance across various datasets. 2025-01-17T03:16:15Z Zekun Zhou Tan Liu Bing Yu Yanru Gong Liu Shi Qiegen Liu http://arxiv.org/abs/2511.05961v1 Photodiode quantum efficiency for 2-μm light in the signal band of gravitational wave detectors 2025-11-08T10:34:02Z Quantum technologies with quantum correlated light require photodiodes with near-perfect `true' quantum efficiency, the definition of which adequately accounts for the photodiode dark noise. Future squeezed-light-enhanced gravitational wave detectors could in principle achieve higher sensitivities with a longer laser wavelength around 2 μm. Photodiodes made of extended InGaAs are available for this range, but the true quantum efficiency at room temperature and the low frequency band of gravitational waves is strongly reduced by dark noise. Here we characterize the change in performance of a commercial extended-InGaAs photodiode versus temperature. While the dark noise decreases as expected with decreasing temperature, the detection efficiency unfortunately also decreases monotonically. Our results indicate the need for a dedicated new design of photodiodes for gravitational wave detectors using 2-μm laser light. 2025-11-08T10:34:02Z Julian Gurs Nils Sueltmann Christian Darsow-Fromm Sebastian Steinlechner Roman Schnabel http://arxiv.org/abs/2406.01044v2 Nuclear Medicine AI in Action: The Bethesda Report (AI Summit 2024) 2025-11-08T03:19:26Z The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript. 2024-06-03T06:54:38Z Arman Rahmim Tyler J. Bradshaw Guido Davidzon Joyita Dutta Georges El Fakhri Munir Ghesani Nicolas A. Karakatsanis Quanzheng Li Chi Liu Emilie Roncali Babak Saboury Tahir Yusufaly Abhinav K. Jha http://arxiv.org/abs/2508.20209v2 Low-exposure, high-quality multimodal speckle X-ray imaging via an intrinsic gradient-flow approach 2025-11-07T18:49:04Z We present a new approach for retrieving dark-field, phase shift, and attenuation images from speckle-based X-ray imaging data. Speckle-based X-ray imaging (SBXI) exploits sample-induced alterations to a reference near-field speckle pattern produced by a randomly structured mask. Attenuation images allow materials of different densities to be visualised. Phase-shift images are useful because they reveal how materials in a sample refract the X-ray beam, providing contrast between similar low-density structures that are difficult to reconstruct in attenuation images. Dark-field images convey information about structures that are smaller than the spatial resolution and thus invisible in both attenuation and phase-shift images. In previous works, we presented the Multimodal Intrinsic Speckle-Tracking (MIST) algorithm, which recovers the three complementary imaging modes from SBXI data by solving the associated Fokker--Planck equation. In this work, we present a variation of MIST, called ``gradient-flow MIST", which (1) reduces the amount of SBXI data required for image retrieval, (2) maintains the full generality of the X-ray Fokker--Planck equation, and (3) recovers dark-field images with higher quality than the previously proposed variants for weakly attenuating (i.e., low density) samples. We demonstrate the new gradient-flow MIST approach on experimental SBXI data of a knotted bundle of carbon fibres acquired at the Australian synchrotron. This approach is anticipated to be useful in phase-contrast and dark-field applications that require simplicity in experimentation and low sample X-ray exposure. 2025-08-27T18:35:03Z 10 pages, 5 figures Jayvan Liu Samantha J. Alloo Max Langer Konstantin M. Pavlov 10.1103/scnz-pqy3 http://arxiv.org/abs/2511.05089v1 A dispersal recolonisation 3D biofilm in vitro model based on co-assembled peptide amphiphiles and clinical wound fluid 2025-11-07T09:08:41Z Chronic wound infections are sustained by dynamic 3D biofilm cycles involving maturation, dispersal, and recolonisation, yet existing in vitro models fail to reproduce these temporal and structural complexities. Here, we report a strategy that co-assembles a designed protease-inhibitory peptide amphiphile (PA-GF) with patient-derived wound fluid (WF) to reconstruct the complete biofilm life cycle in vitro. The PA-GF sequence incorporates an HWGF motif capable of binding and inhibiting matrix metalloproteinase-9 (MMP-9), thereby preserving the integrity of recolonised biofilms under proteolytic stress. Co-assembling with WF generated a living material that faithfully mimicked the biochemical and mechanical microenvironment of chronic wounds, supporting the formation of stable 3D biofilms capable of dispersal and recolonisation. Furthermore, we established a controllable polymicrobial infection model and validated its translational relevance through antibiotic susceptibility profiling and spatial microbiological analyses. Notably, the antibiotic response patterns of the PA/WF-derived biofilms closely mirrored those observed in a rat wound infection in vivo model. Collectively, our findings demonstrate that co-assembling living materials can recapitulate the nutritional composition, 3D architecture, and recolonisation dynamics of in vivo infectious biofilms, offering a physiologically relevant and customisable platform for investigating chronic wound infections and accelerating anti-biofilm drug discovery. 2025-11-07T09:08:41Z Zhiquan Yu Chenjia Zhao Lingyun Xiong Shanshan Su Dawen Yu Shilu Zhang Yubin Ke Hua Yang Guo Zhang Jiaming Sun Nengqiang Guo Yuanhao Wu http://arxiv.org/abs/2504.08499v2 From Radiation Dose to Cellular Dynamics: A Discrete Model for Simulating Cancer Therapy 2025-11-06T08:08:42Z Radiation therapy is one of the most common cancer treatments, and dose optimization and targeting of radiation are crucial since both cancerous and healthy cells are affected. Different mathematical and computational approaches have been developed for this task. The most common mathematical approach, dating back to the late 1970's, is the linear-quadratic (LQ) model for the survival probability given the radiation dose. Most simulation models consider tissue as a continuum rather than consisting of discrete cells. While reasonable for large-scale models (e.g., human organs), continuum approaches necessarily neglect cellular-scale effects, which may play a role in growth, morphology, and metastasis of tumors. Here, we propose a method for modeling the effect of radiation on cells based on the mechanobiological \textsc{CellSim3D} simulation model for growth, division, and proliferation of cells. To model the effect of a radiation beam, we incorporate a Monte Carlo procedure into \textsc{CellSim3D} with the LQ model by introducing a survival probability at each beam delivery. Effective removal of dead cells by phagocytosis was also implemented. Systems with two types of cells were simulated: stiff slowly proliferating healthy cells and soft rapidly proliferating cancer cells. For model verification, the results were compared to prostate cancer (PC-3 cell line) data for different doses and we found good agreement. In addition, we simulated proliferating systems and analyzed the probability density of the contact forces. We determined the state of the system with respect to the jamming transition and found very good agreement with experiments. 2025-04-11T12:57:29Z Mirko Bagnarol Gianluca Lattanzi Jan Åström Mikko Karttunen http://arxiv.org/abs/2511.03876v1 Computed Tomography (CT)-derived Cardiovascular Flow Estimation Using Physics-Informed Neural Networks Improves with Sinogram-based Training: A Simulation Study 2025-11-05T21:44:47Z Background: Non-invasive imaging-based assessment of blood flow plays a critical role in evaluating heart function and structure. Computed Tomography (CT) is a widely-used imaging modality that can robustly evaluate cardiovascular anatomy and function, but direct methods to estimate blood flow velocity from movies of contrast evolution have not been developed. Purpose: This study evaluates the impact of CT imaging on Physics-Informed Neural Networks (PINN)-based flow estimation and proposes an improved framework, SinoFlow, which uses sinogram data directly to estimate blood flow. Methods: We generated pulsatile flow fields in an idealized 2D vessel bifurcation using computational fluid dynamics and simulated CT scans with varying gantry rotation speeds, tube currents, and pulse mode imaging settings. We compared the performance of PINN-based flow estimation using reconstructed images (ImageFlow) to SinoFlow. Results: SinoFlow significantly improved flow estimation performance by avoiding propagating errors introduced by filtered backprojection. SinoFlow was robust across all tested gantry rotation speeds and consistently produced lower mean squared error and velocity errors than ImageFlow. Additionally, SinoFlow was compatible with pulsed-mode imaging and maintained higher accuracy with shorter pulse widths. Conclusions: This study demonstrates the potential of SinoFlow for CT-based flow estimation, providing a more promising approach for non-invasive blood flow assessment. The findings aim to inform future applications of PINNs to CT images and provide a solution for image-based estimation, with reasonable acquisition parameters yielding accurate flow estimates. 2025-11-05T21:44:47Z Jinyuxuan Guo Gurnoor Singh Khurana Alejandro Gonzalo Grande Juan C. del Alamo Francisco Contijoch 10.1002/mp.70519 http://arxiv.org/abs/2501.12396v2 A One Dimensional (1D) Computational Fluid Dynamics Study of Fontan-Associated Liver Disease (FALD) 2025-11-05T15:57:55Z Fontan-Associated Liver Disease (FALD) is a disorder arising from hemodynamic changes and venous congestion in the liver. This disease is prominent in patients with hypoplastic left heart syndrome (HLHS). Although HLHS patients typically survive into adulthood, they have reduced cardiac output due to their univentricular physiology (i.e., a Fontan circuit). As a result, they have insufficient blood delivery to the liver. In comparison, patients with double outlet right ventricle (DORV), also having a univentricular circuit, have lower incidence of FALD. In this study, we use a patient-specific, one-dimensional computational fluid dynamics (1D-CFD) model to predict hemodynamics in the liver of an HLHS patient and compare predictions with an age- and size-matched DORV control patient. Additionally, we simulate FALD conditions in the HLHS patient to predict hemodynamic changes across various stages of disease progression. Our results show that the HLHS patient has a higher portal venous pressure compared to the DORV patient. This difference is exacerbated as FALD conditions progress. The wall shear stress (WSS) is also higher than normal for the HLHS patient, suggesting vascular remodeling. WSS decreases slightly under FALD conditions, consistent with the development of portal hypertension. Perfusion analysis gives insight into regions of liver tissue at risk for fibrosis development, showing increasing pressures and reduced flow throughout the liver tissue fed by the portal vein under FALD conditions. Our results provide insight into the specific hemodynamic changes in Fontan circulation that can cause FALD. 2025-01-06T15:36:26Z Yaqi Li Justin D. Weigand Charles Puelz Mette S. Olufsen Alyssa Taylor-LaPole