https://arxiv.org/api/QSPZAnseXnkoWEvKE/sI23q7cm42026-06-24T07:52:13Z900170515http://arxiv.org/abs/2511.16633v1The First In Vitro and In Vivo Validation of the Hessian-Free Ray-Born Inversion for Quantitative Ultrasound Tomography2025-11-20T18:38:54ZThis study presents the first experimental validation of a Hessian-free ray-Born inversion technique for quantitative reconstruction of sound speed from transmission ultrasound data. The method combines single-scattering theory with high-frequency approximations, yielding an inversion framework well suited to the frequency ranges used in clinical ultrasound applications. Unlike previous singly-scattered inversion approaches that account for medium heterogeneities only in the scattering potential, the proposed ray-Born method employs Green's functions approximated along ray trajectories determined by high-frequency assumptions. The associated objective function is linearized and minimized sequentially across increasing frequency bands. At each frequency set, the linearized subproblem is solved using a weighting scheme applied to both the solution and data spaces, which diagonalizes the Hessian and enables its inversion in a single step. The method, previously reported and released as an open-source package, was applied to in-vitro and in-vivo datasets provided by the University of Rochester Medical Center. The reconstructed images were evaluated by comparison with those obtained using a full-wave inversion approach based on a frequency-domain Helmholtz solver. The results demonstrate the strong potential of the Hessian-free ray-Born inversion as a computationally efficient and accurate method suitable for clinical translation.2025-11-20T18:38:54ZFigures 1-4, each contains 8 subfigures (a-h)Ashkan Javaherianhttp://arxiv.org/abs/2507.22152v2Enhancing efficiency in paediatric brain tumour segmentation using a pathologically diverse single-center clinical dataset2025-11-20T10:24:22ZBackground Brain tumours are the most common solid malignancies in children, encompassing diverse histological, molecular subtypes and imaging features and outcomes. Paediatric brain tumours (PBTs), including high- and low-grade gliomas (HGG, LGG), medulloblastomas (MB), ependymomas, and rarer forms, pose diagnostic and therapeutic challenges. Deep learning (DL)-based segmentation offers promising tools for tumour delineation, yet its performance across heterogeneous PBT subtypes and MRI protocols remains uncertain. Methods A retrospective single-centre cohort of 174 paediatric patients with HGG, LGG, medulloblastomas (MB), ependymomas, and other rarer subtypes was used. MRI sequences included T1, T1 post-contrast (T1-C), T2, and FLAIR. Manual annotations were provided for four tumour subregions: whole tumour (WT), T2-hyperintensity (T2H), enhancing tumour (ET), and cystic component (CC). A 3D nnU-Net model was trained and tested (121/53 split), with segmentation performance assessed using the Dice similarity coefficient (DSC) and compared against intra- and inter-rater variability. Results The model achieved robust performance for WT and T2H (mean DSC: 0.85), comparable to human annotator variability (mean DSC: 0.86). ET segmentation was moderately accurate (mean DSC: 0.75), while CC performance was poor. Segmentation accuracy varied by tumour type, MRI sequence combination, and location. Notably, T1, T1-C, and T2 alone produced results nearly equivalent to the full protocol. Conclusions DL is feasible for PBTs, particularly for T2H and WT. Challenges remain for ET and CC segmentation, highlighting the need for further refinement. These findings support the potential for protocol simplification and automation to enhance volumetric assessment and streamline paediatric neuro-oncology workflows.2025-07-29T18:33:15ZA. Jakab and F. Kofler have shared last authorshipA. PifferDivision of Oncology and Children's Research Center, University Children's Hospital Zurich, Zurich, SwitzerlandJ. A. BuchnerDepartment of Radiation Oncology, TUM School of Medicine and Health, Klinikum rechts der Isar, Technical University of Munich, Munich, GermanyInstitute of Radiation MedicinePartner Site Munich, German Consortium for Translational Cancer ResearchA. G. GennariDepartment of Neuropaediatrics, University Children's Hospital Zurich, SwitzerlandCenter for MR- Research, University Children's Hospital Zurich, Zurich, SwitzerlandP. GrehtenDepartment of Diagnostic Imaging, University Children's Hospital Zurich, Zurich, SwitzerlandS. SirinDepartment of Diagnostic Imaging, University Children's Hospital Zurich, Zurich, SwitzerlandE. RossGeorgia Institute of Technology, Geisel School of Medicine at DartmouthI. EzhovDepartment of Computer Science, TUM School of Computation, Information and Technology, Technical University of Munich, Munich, GermanyTranslaTUM - Central Institute for Translational Cancer Research, Technical University of Munich, MunichM. RosierHelmholtz AI, Helmholtz Zentrum Munich, Munich, GermanyDepartment of Quantitative Biomedicine, University of Zurich, Zurich, SwitzerlandJ. C. PeekenDepartment of Radiation Oncology, TUM School of Medicine and Health, Klinikum rechts der Isar, Technical University of Munich, Munich, GermanyM. PiraudHelmholtz AI, Helmholtz Zentrum Munich, Munich, GermanyB. MenzeDepartment of Quantitative Biomedicine, University of Zurich, Zurich, SwitzerlandA. Guerreiro StücklinDivision of Oncology and Children's Research Center, University Children's Hospital Zurich, Zurich, SwitzerlandA. JakabCenter for MR- Research, University Children's Hospital Zurich, Zurich, SwitzerlandFaculty of Medicine, University of Zürich, SwitzerlandF. KoflerTranslaTUM - Central Institute for Translational Cancer Research, Technical University of Munich, MunichHelmholtz AI, Helmholtz Zentrum Munich, Munich, GermanyDepartment of Quantitative Biomedicine, University of Zurich, Zurich, SwitzerlandDepartment of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germanyhttp://arxiv.org/abs/2501.11875v2Developing an Agent-Based Mathematical Model for Simulating Post-Irradiation Cellular Response: A Crucial Component of a Digital Twin Framework for Personalized Radiation Treatment2025-11-19T22:06:31ZIn this study, we present the Physical-Bio Translator, an agent-based simulation model designed to simulate cellular responses following irradiation. This simulation framework is based on a novel cell-state transition model that accurately reflects the characteristics of irradiated cells. To validate the Physical-Bio Translator, we performed simulations of cell phase evolution, cell phenotype evolution, and cell survival. The results indicate that the Physical-Bio Translator effectively replicates experimental cell irradiation outcomes, suggesting that digital cell irradiation experiments can be conducted via computer simulation, offering a more sophisticated model for radiation biology. This work lays the foundation for developing a robust and versatile digital twin at multicellular or tissue scales, aiming to comprehensively study and predict patient responses to radiation therapy.2025-01-21T04:11:04ZRuirui LiuMarciek H. SwatJames A. GlazierYu LeiSumin ZhouKathryn A. Higleyhttp://arxiv.org/abs/2510.03465v2Seeing More, Treating Smarter: Role of Long-Axial Field-of-View PET-CT in The Evolution of Theranostics2025-11-19T20:33:16ZLong-axial field-of-view (LAFOV) PET/CT has the potential to redefine the role of molecular imaging in theranostics by making multiparametric whole-body (MPWB) imaging and predictive dosimetry more clinically feasible. Compared to conventional PET systems, LAFOV scanners provide dramatic gains in sensitivity and coverage, allowing dynamic acquisitions, delayed imaging, and dual-tracer protocols within clinically feasible workflows. These advances supply the quantitative data required for physiologically based pharmacokinetic (PBPK) modeling and the creation of theranostic digital twins, supporting true personalization of radiopharmaceutical therapy.2025-10-03T19:37:36ZPedro L. EsquinasFereshteh YousefiriziIan AlbertsNicolas A. KarakatsanisArman RahmimCarlos F. Uribehttp://arxiv.org/abs/2511.15761v1The Emory Optic Nerve Head Atlas - Using 3D Anatomical Mapping to Study Optic Neuropathies with an Initial Focus on Glaucoma2025-11-19T13:50:50ZPurpose: To develop the first 3D optic nerve head (ONH) atlas using AI-based registration and evaluate its use in: (1) atlas-adjusted retinal nerve fiber layer (RNFL) analysis for glaucoma diagnosis, and (2) strain-based assessment of glaucoma severity. Methods: Large-scale OCT datasets were registered using REFLECTIVITY-generated tissue segmentations. A healthy atlas (n=460) and glaucoma atlases for mild (n=852), moderate (n=640), and severe (n=546) disease were built using an AI-driven algorithm incorporating structural and biomechanical constraints. Atlas quality was evaluated using inter-layer contrast and agreement between warped scans and the template. Atlas-adjusted RNFL thickness was extracted by mapping fixed 1.5 mm BMO-based reference points from the atlas to each subject and compared with standard subject-specific RNFL measurements. Effective strain relative to each atlas was computed by morphing subjects to the atlas template. Strain and thickness features were used to classify glaucoma severity. Results: The healthy atlas captured normative ONH anatomy, while glaucoma atlases showed stage-dependent changes. Registration accuracy was high (NCC=0.86+-0.05; Dice=0.90+-0.02), with strong inter-layer contrast (0.40+-0.03). Atlas-adjusted RNFL thickness improved separation between healthy and mild glaucoma (Cohen's d=0.77 vs. 0.72). Classification using atlas-adjusted profiles outperformed native measurements (AUC=0.771 vs. 0.757). Mean effective strain differed significantly across severity groups (ANOVA p<0.05), and CNNs trained on strain maps achieved strong classification (AUC=0.79). Conclusion: The ONH atlas provides a population-derived structural reference enabling anatomically consistent thickness mapping and strain-based characterization. It enhances diagnostic discrimination, supports severity classification, and offers a framework to study glaucomatous biomechanics.2025-11-19T13:50:50ZThanadet ChuangsuwanichPatipol TiyajamornYibo ChenMichael DattiloDeepta GhateNancy NewmanValérie BiousseMichaël J. A. Girardhttp://arxiv.org/abs/2511.15336v1On the phase aberration estimation using common mid-angle correlations2025-11-19T10:56:27ZPhase aberrations, despite degrading ultrasound images, also encode valuable information about the spatial distribution of the speed of sound in tissue. In pulse-echo ultrasound, we can quantify them by exploiting speckle correlations. Among existing strategies, correlations between steered acquisitions that share a common mid-angle have proven particularly effective for inferring the speed of sound. Their phases can be linearly related to the phase aberrations undergone by both the incident and reflected wavefronts. This relationship has so far been demonstrated only through geometric arguments based on point reflectors. Here, we develop a rigorous theoretical formalism that extends this relationship to the speckle regime, completing the previously established linear model and clarifying its underlying assumptions. More importantly, we build on this formalism to analyze correlation-phase fluctuations arising from aberration-induced speckle decorrelation. The analysis reveals that phase variance is governed by the relative loss of coherence, which increases approximately linearly with the square of the correlation phases. Local correlation-phase estimates therefore become increasingly uncertain as their magnitude grows. Experimental measurements in a uniform tissue-mimicking phantom show excellent agreement with the predicted variance. Beyond providing a theoretical basis for advancing speed-of-sound imaging, this formalism establishes the accuracy limit of common-mid-angle correlation phases, offering a benchmark for evaluating more advanced aberration-estimation techniques.2025-11-19T10:56:27Z10 pages, 7 figuresNaiara Korta MartiartuMichael Jaegerhttp://arxiv.org/abs/2511.14971v1Clinical Validation and Prospective Deployment of an Automated Deep Learning-Based Coronary Segmentation and Cardiac Toxicity Risk Prediction System2025-11-18T23:38:01ZImportance: Coronary algorithm for cardiac sub structures and prospective real-time surveillance of cardiac dose exposure. Methods: Retro and prospective study to validate AI auto-segmentation. A 3D UNet was trained on 560 thoracic CT scans from a single institution (2003-2014) and validated internally (n=70). External validation was performed in 283 patients treated at an independent institution (2005-2020). Clinical implementation comprised (1) retrospective analysis of 3,399 lung cancer patients treated in 2014-2022 and (2) prospective surveillance of 1,386 consecutive patients in 2023. Geometric accuracy, concordance of dose-volume parameters; association of AI-derived substructure metrics with outcome; temporal dose trends; and the proportion of patients exceeding prespecified risk. Results: Median (inter-quartile range) Dice/ASSD were 0.95 (0.94-0.96)/1.1 mm for the heart and 0.87 (0.82-0.90)/1.9 mm for the LAD; the median absolute difference between AI and manual LAD V15 was 1%. AI-derived LAD V15 remained independently associated with MACE (sub distribution hazard ratio [HR], 1.03%; 95% CI, 1.01-1.05) and ACM (adjusted HR, 1.02; 95% CI, 1.00-1.03), internally and externally. Retrospective deployment showed a 32% relative decline in median LAD V15 from 2014 to 2022 (12% to 8%) and identified high- risk doses in 1,086 of 3,399 patients (32%). Prospective surveillance flagged 264 contemporary patients (19%) for potential cardiology referral. Conclusions: A validated AI system accurately segments cardiac substructures, reproduces dose-outcome relationships, enables large-scale surveillance, and point-of-care alerts for high-risk patients. Automated cardiac dose monitoring could facilitate adoption of coronary-sparing therapy and follow-up.2025-11-18T23:38:01ZChristian V. GuthierChristopher E KehayiasCosmin CiausuJordan O. GashoJohn HeMaria OorloffSamuel C. ZhangDanielle S. BittermanJeremy S. BredfeldtKelly FitzgeraldBenjamin H. KannDavid E. KozonoJennifer SteersMarion TonneauAnju NohriaHugo J. W. L. AertsKatelyn M. AtkinsRaymond H. Makhttp://arxiv.org/abs/2511.14886v1Membrane stepping optimization in Modulation Based Imaging2025-11-18T20:10:53ZModulation-based imaging (MoBI) is an X-ray phase-contrast technique that uses an intensity modulator (or membrane) in the beam. Although MoBI can be performed in a single shot, multiple exposures are typically needed to improve the quality of the result. The membrane is typically moved using a regular stepping pattern for convenience; however, the impact of the membrane movement scheme on image quality has not been fully investigated yet. In this work, we explore optimized movement strategies aiming at improving MoBI performance. An experimental study tested optimization schemes based on global and local standard deviation metrics, and compared them with regular and random stepping motions. The results demonstrated superior contrast-to-noise ratio and reduced angular sensitivity in the optimized approaches compared to conventional stepping. These results were consistent across different membrane types, with honeycomb membranes showing the highest compatibility with the optimization procedure. Noise power spectrum analysis further validated the advantages of the optimized motion strategies. Overall, the results demonstrate that an optimized membrane movement can significantly improve MoBI image quality without increasing experimental complexity.2025-11-18T20:10:53Z8 pages, 6 figuresPaola PerionClara MagninFulvia ArfelliBertrand FaureRalf Hendrik MenkEmmanuel Brunhttp://arxiv.org/abs/2511.13980v1Enabling Real-Time Volumetric Imaging in Interventional Radiology Suits via a Deep Learning Framework Robust to C-arm Tilt2025-11-17T23:19:08ZContemporary interventional imaging lacks the real-time 3D guidance needed for the precise localization of mobile thoracic targets. While Cone-Beam CT (CBCT) provides 3D data, it is often too slow for dynamic motion tracking. Deep learning frameworks that reconstruct 3D volumes from sparse 2D projections offer a promising solution, but their performance under the geometrically complex, non-zero tilt acquisitions common in interventional radiology is unknown. This study evaluates the robustness of a patient-specific deep learning framework, designed to estimate 3D motion, to a range of C-arm cranial-caudal tilts. Using a 4D digital phantom with a simulated respiratory cycle, 2D X-ray projections were simulated at five cranial-caudal tilt angles across 10 breathing phases. A separate deep learning model was trained for each tilt condition to reconstruct 3D volumetric images. The framework demonstrated consistently high-fidelity reconstruction across all tilts, with a mean Structural Similarity Index (SSIM) > 0.980. While statistical analysis revealed significant differences in performance between tilt groups (p < 0.0001), the absolute magnitude of these differences was minimal (e.g., the mean absolute difference in SSIM across all tilt conditions was ~0.0005), indicating they were not functionally significant. The magnitude of respiratory motion was found to be the dominant factor influencing accuracy, with the impact of C-arm tilt being a much smaller, secondary effect. These findings demonstrate that a patient-specific, motion-estimation-based deep learning approach is robust to geometric variations encountered in realistic clinical scenarios, representing a critical step towards enabling real-time 3D guidance in flexible interventional settings.2025-11-17T23:19:08ZFawazilla UtomoTess ReynoldsNicholas Hindleyhttp://arxiv.org/abs/2511.13955v1Contactless Monitoring of Muscle Vibrations During Exercise with a Chaos-Inspired Radar2025-11-17T22:30:09ZIn this paper, our goal is to enable quantitative feedback on muscle fatigue during exercise to optimize exercise effectiveness while minimizing injury risk. We seek to capture fatigue by monitoring surface vibrations that muscle exertion induces. Muscle vibrations are unique as they arise from the asynchronous firing of motor units, producing surface micro-displacements that are broadband, nonlinear, and seemingly stochastic. Accurately sensing these noise-like signals requires new algorithmic strategies that can uncover their underlying structure. We present GigaFlex the first contactless system that measures muscle vibrations using mmWave radar to infer muscle force and detect fatigue. GigaFlex draws on algorithmic foundations from Chaos theory to model the deterministic patterns of muscle vibrations and extend them to the radar domain. Specifically, we design a radar processing architecture that systematically infuses principles from Chaos theory and nonlinear dynamics throughout the sensing pipeline, spanning localization, segmentation, and learning, to estimate muscle forces during static and dynamic weight-bearing exercises. Across a 23-participant study, GigaFlex estimates maximum voluntary isometric contraction (MVIC) root mean square error (RMSE) of 5.9\%, and detects one to three Repetitions in Reserve (RIR), a key quantitative muscle fatigue metric, with an AUC of 0.83 to 0.86, performing comparably to a contact-based IMU baseline. Our system can enable timely feedback that can help prevent fatigue-induced injury, and opens new opportunities for physiological sensing of complex, non-periodic biosignals.2025-11-17T22:30:09ZSenSys '26: Proceedings of the 2026 ACM/IEEE International Conference on Embedded Artificial Intelligence and Sensing Systems, 2026Jiangyifei ZhuYuzhe WangTao QiangVu PhanZhixiong LiEvy MeindersEni HalilajJustin ChanSwarun Kumar10.1145/3774906.3802776http://arxiv.org/abs/2511.13634v1Exploring the production of Terbium-161 in the Brazilian Multipurpose Reactor2025-11-17T17:48:24ZThe Brazilian Multipurpose Reactor (RMB) was conceived to meet national needs for radioisotope production, materials irradiation testing, and neutron beam applications. In addition to its 30~MW pool-type reactor, the RMB complex will include additional facilities for radioisotope production and related applications. $^{161}Tb$ is a promising radionuclide for radiopharmaceutical therapy, offering decay properties similar to $^{177}Lu$ but with additional conversion and Auger electrons that enhance dose delivery to cancer cells. In light of this emerging radioisotope, this study explores the potential production of $^{161}Tb$ in the RMB through neutron irradiation of enriched $Gd_{2}O_{3}$ targets. Monte Carlo (MCNP) simulations provided detailed neutron flux distributions, which were used as input for ORIGEN calculations of isotope buildup. Assuming 10 mg targets enriched to 97.5% in $^{160}Gd$, a 40-day irradiation, and a thermal flux of $2 \cdot 10^{14}$ $n/cm^{2}s$, the results indicate that $^{161}Tb$ activity reaches approximately 4.5 GBq after 14 days ($\approx 450 GBq/g$), in agreement with data from other research reactors. Building on prior studies that demonstrated the RMB's capability to irradiate larger targets, terabecquerel-scale yields appear feasible. These findings highlight the RMB's potential to support domestic production of emerging therapeutic radionuclides such as $^{161}Tb$. The potential for isotopic enrichment of $^{160}Gd$ using the AVLIS method is also discussed.2025-11-17T17:48:24Z8 pages, 4 figuresFernando Cozim MelgesJhonatha Ricardo SantosLuiz Paulo de OliveiraAlexandre Pinho dos Santos SouzaCarlos Gabriel Santos da SilvaIberê Souza Ribeiro JúniorBarbara Perez Gonçalves SilvaMarco Antonio Stanojev PereiraFrederico Antonio Genezinihttp://arxiv.org/abs/2508.04685v2Phase-Pole-Free Images and Smooth Coil Sensitivity Maps by Regularized Nonlinear Inversion2025-11-17T17:12:49ZPurpose: Phase singularities are a common problem in image reconstruction with auto-calibrated sensitivities due to an inherent ambiguity of the estimation problem. The purpose of this work is to develop a method for detecting and correcting phase poles in non-linear inverse (NLINV) reconstruction of MR images and coil sensitivity maps.
Methods: Phase poles are detected in individual coil sensitivity maps by computing the curl in each pixel. A weighted average of the curl in each coil is computed to detect phase poles. Phase pole detection and correction is then integrated into the iteratively regularized Gauss-Newton method of the NLINV algorithm, which then avoid phase singularities in the reconstructed images. The method is evaluated for reconstruction of accelerated Cartesian MPRAGE data of the brain and interactive radial real-time MRI of the human heart.
Results: Phase poles are reliably removed in NLINV reconstructions for both applications. NLINV with phase pole correction can reliably and efficiently estimate coil sensitivity profiles free from singularities even from very small ($7\times7$) auto-calibration (AC) regions.
Conclusion: NLINV emerges as an efficient and reliable tool for image reconstruction and coil sensitivity estimation in challenging MRI applications.2025-08-06T17:47:53ZSubmitted to Magnetic Resonance in MedicineMagnetic Resonance in Medcine 2026;96:134-145Moritz BlumenthalMartin Uecker10.1002/mrm.70333http://arxiv.org/abs/2511.13307v1Operational and biomechanical evaluation of a wrist exoskeleton prototype for assisting meat cutting tasks2025-11-17T12:37:48ZAlthough a growing number of exoskeletons have been developed for occupational applications, wrist exoskeletons remain relatively rare. However, in the meat processing industry, elbow and hand-wrist musculoskeletal disorders are particularly common. The aim of this study was to assess the potential effectiveness and risks of a 670g wrist exoskeleton prototype designed to assist operators during meat cutting tasks. Six professional butchers performed three standardized tasks reproducing meat cutting gestures in foam, in three randomized experimental conditions: (1) without exoskeleton, (2) wearing the exoskeleton passive, with brakes off and (3) using it with brakes activated, locked in a static position. Cutting forces were recorded using an instrumented table, joint angles using an optoelectronic motion capture system, muscle activity using surface EMG and user experience was assessed using questionnaires. The cutting inaccuracy was defined as the area between the prescribed task and the actual cut on the foam surface. Joint torques were estimated by inverse dynamics with and without taking the exoskeleton's mass into account, to isolate its effect. Linear mixed-effects statistical models were fitted. With the exoskeleton active during tasks, EMG activity was decreased of up to 18.7% (p<0.01 to p<0.001) in the wrist flexors and increased of up to 61.7% (not significant to p<0.05) in the upper trapezius. Shoulder elevation joint torques were increased of up to 39.7% (p<0.001), mainly due to the exoskeleton mass. The proposed multi-criteria exoskeleton evaluation has provided guidance for following prototyping stages. Too heavy wrist exoskeletons could increase the risk of shoulder tendinitis for such tasks.2025-11-17T12:37:48ZAurélie TomezzoliIRISA, ComBOMathieu GréauUR, ComBO, IRISACharles PontonnierUR, ComBO, IRISAhttp://arxiv.org/abs/2511.12907v1Guidewire-driven deployment of high density ECoG arrays for large area brain-computer interface2025-11-17T02:54:40ZElectrocorticographic brain computer interfaces are powerful emergent technologies for advancing basic neuroscience research and targeted clinical interventions. However, existing devices require trade-offs between coverage area, electrode density, surgical invasiveness and complication risk: limitations that fail to meet the demands of next-generation BCI. Here, we report a guidewire-driven deployable ECoG BCI device that can be epidurally implanted using minimally invasive procedures. Our ultra-flexible but strong thin-film electrode array, which packs 256 electrodes into 4 cm2, can be folded, pulled through millimetre-sized skull holes, and unfurled seamlessly onto the brain dura mater. When deployed on the canine brain, it captures abundant high-quality auditory neural signals with distinct features of hearing that can be used to classify sound types with over 80% accuracy using various standard machine learning models. Our device is biocompatible for chronic monitoring, easy and fast to deploy and importantly, resolves the key trade-offs limiting current BCI technologies.2025-11-17T02:54:40ZTao ZouDepartment of Mechanical Engineering, The University of Hong Kong, Hong KongAdvanced Biomedical Instrumentation Centre Limited, Hong Kong Science Park, Hong KongNa XiaoAdvanced Biomedical Instrumentation Centre Limited, Hong Kong Science Park, Hong KongRuihong WengAdvanced Biomedical Instrumentation Centre Limited, Hong Kong Science Park, Hong KongYifan GuoDepartment of Mechanical Engineering, The University of Hong Kong, Hong KongAdvanced Biomedical Instrumentation Centre Limited, Hong Kong Science Park, Hong KongDanny Tat Ming ChanNeurosurgery Division, Department of Surgery, The Chinese University of Hong Kong, Hong KongGilberto Ka Kit LeungDepartment of Surgery, The University of Hong Kong, Hong KongPaddy Kwok Leung ChanDepartment of Mechanical Engineering, The University of Hong Kong, Hong KongAdvanced Biomedical Instrumentation Centre Limited, Hong Kong Science Park, Hong Konghttp://arxiv.org/abs/2501.13485v2Particle migration in areas of constricted flow2025-11-16T17:46:36ZCardiovascular diseases are a leading cause of death globally. Among them, some are linked to stenosis, which is an abnormal narrowing of blood vessels, as well as other factors. Smart drug delivery systems based on micro- and nanoparticles are a promising method to offer non/minimal-invasive therapeutic mechanisms. Here we investigate the propensity of particles with different shapes and sizes to drift laterally (marginate) towards an occlusion area in a two-dimensional (2D) parallel plate laminar flow using the Lattice-Boltzmann method (LBM). To verify the outcomes on both sides of the stenosis, a probability of adhesion to the borders was calculated. Analysis was done on the impact of wall-shear stress on both sides of the stenosis. Our results show that rectangular particles migrate in larger amounts and earlier than circular ones.2025-01-23T08:59:02ZR. Dapena-GarcíaV. Pérez-Muñuzuri