https://arxiv.org/api/NTDtxV16SbNwaWMRIf/lehObtio2026-06-24T06:50:37Z900169015http://arxiv.org/abs/2512.03054v1Energy-Efficient Federated Learning via Adaptive Encoder Freezing for MRI-to-CT Conversion: A Green AI-Guided Research2025-11-25T14:35:51ZFederated Learning (FL) holds the potential to advance equality in health by enabling diverse institutions to collaboratively train deep learning (DL) models, even with limited data. However, the significant resource requirements of FL often exclude centres with limited computational infrastructure, further widening existing healthcare disparities. To address this issue, we propose a Green AI-oriented adaptive layer-freezing strategy designed to reduce energy consumption and computational load while maintaining model performance. We tested our approach using different federated architectures for Magnetic Resonance Imaging (MRI)-to-Computed Tomography (CT) conversion. The proposed adaptive strategy optimises the federated training by selectively freezing the encoder weights based on the monitored relative difference of the encoder weights from round to round. A patience-based mechanism ensures that freezing only occurs when updates remain consistently minimal. The energy consumption and CO2eq emissions of the federation were tracked using the CodeCarbon library. Compared to equivalent non-frozen counterparts, our approach reduced training time, total energy consumption and CO2eq emissions by up to 23%. At the same time, the MRI-to-CT conversion performance was maintained, with only small variations in the Mean Absolute Error (MAE). Notably, for three out of the five evaluated architectures, no statistically significant differences were observed, while two architectures exhibited statistically significant improvements. Our work aligns with a research paradigm that promotes DL-based frameworks meeting clinical requirements while ensuring climatic, social, and economic sustainability. It lays the groundwork for novel FL evaluation frameworks, advancing privacy, equity and, more broadly, justice in AI-driven healthcare.2025-11-25T14:35:51Z22 pages, 13 figuresCiro Benito RaggioLucia MigliorelliNils SkupienMathias Krohmer ZabaletaOliver BlanckFrancesco CiconeGiuseppe Lucio CasciniPaolo ZaffinoMaria Francesca Spadeahttp://arxiv.org/abs/2510.13006v3What is Implementation Science; and Why It Matters for Bridging the Artificial Intelligence Innovation-to-Application Gap in Medical Imaging2025-11-24T19:53:22ZThe transformative potential of artificial intelligence (AI) in medical Imaging (MI) is well recognized. Yet despite promising reports in research settings, many AI tools fail to achieve clinical adoption in practice. In fact, more generally, there is a documented 17-year average delay between evidence generation and implementation of a technology. Implementation science (IS) may provide a practical, evidence-based framework to bridge the gap between AI development and real-world clinical imaging use, to shorten this lag through systematic frameworks, strategies, and hybrid research designs. We outline challenges specific to AI adoption in MI workflows, including infrastructural, educational, and cultural barriers. We highlight the complementary roles of effectiveness research and implementation research, emphasizing hybrid study designs and the role of integrated KT (iKT), stakeholder engagement, and equity-focused co-creation in designing sustainable and generalizable solutions. We discuss integration of Human-Computer Interaction (HCI) frameworks in MI towards usable AI. Adopting IS is not only a methodological advancement; it is a strategic imperative for accelerating translation of innovation into improved patient outcomes.2025-10-14T21:50:31ZAhmad Fayaz-BakhshJanice TaniaSyaheerah Lebai LutfiAbhinav K. JhaArman Rahmimhttp://arxiv.org/abs/2511.02814v2Production of High-Specific-Activity Radioisotopes Using High-Energy Fusion Neutrons2025-11-24T17:09:37ZWe show that transmutation driven by high-energy neutrons from deuterium-tritium (D-T) fusion reactions can produce many important medical radioisotopes - including $^{32}$P, $^{60}$Co, $^{64}$Cu, $^{89}$Sr, $^{90}$Y, $^{89}$Zr, $^{99}$Mo/$^{99\mathrm{m}}$Tc, $^{103}$Pd, $^{111}$In, $^{117}$In/$^{117\mathrm{m}1}$Sn, $^{123}$I, $^{125}$I, $^{131}$I, $^{133}$Xe, $^{153}$Sm, $^{166}$Ho, $^{177}$Lu, $^{188}$Re, and $^{192}$Ir-and emerging isotopes such as $^{47}$Sc, $^{67}$Cu, $^{103}$Ru/$^{103\mathrm{m}}$Rh, $^{103}$Pd/$^{103\mathrm{m}}$Rh, $^{119}$Sb, $^{124}$I, $^{155}$Tb, $^{161}$Tb, $^{195\mathrm{m}1}$Ir/$^{195\mathrm{m}}$Pt, and $^{225}$Ac with high specific activity and in large quantities. These reactions involve stable, abundant feedstocks and non-fission transmutation channels that change the proton number, enabling chemical separation of the product. Fusion-based transmutation could provide a flexible and proliferation-resistant platform for supply of high-purity isotopes. A D-T neutron source operating at a few megawatts of fusion power could meet or exceed global demand for most major radioisotopes. Further research is required to develop tailored approaches for feedstock processing and product extraction.2025-11-04T18:38:38Z10 pages, 6 figuresJ. F. ParisiA. RutkowskiJ. HarterJ. A. SchwartzS. Chenhttp://arxiv.org/abs/2511.19226v1In-vivo imaging with a low-cost MRI scanner and cloud data processing in low-resource settings2025-11-24T15:30:00ZPurpose: To demonstrate in-vivo imaging with a low-cost, low-field MRI scanner built and operated in Africa, and to show how systematic hardware and software improvements can mitigate the main operational limitations encountered in low-resource environments. Methods: A 46 mT Halbach scanner located at the Mbarara University of Science and Technology (Uganda) was upgraded through a complete reorganization of grounding and shielding, installation of new control electronics and open-source user-interface software. Noise performance was quantified using a standardized protocol and in-vivo brain images were acquired with three-dimensional RARE sequences. Distortion correction was implemented using cloud-based reconstructions incorporating magnetic field maps. Results: The revamped system reached noise levels routinely below three times the thermal limit and demonstrated stable operation over multi-day measurements. Three-dimensional T1- and T2-weighted brain images were successfully acquired and distortion-corrected with remote GPU-based reconstructions and near real-time visualization through the user interface. Conclusions: The results show that low-cost MRI systems can achieve clinically relevant image quality when electromagnetic noise and power-grid instabilities are properly addressed. This work highlights the feasibility of sustainable MRI development in low-resource settings and identifies stable power delivery and local capacity building as the key next steps toward clinical translation.2025-11-24T15:30:00Z10 pages, 10 figures, comments welcomeTeresa Guallart-NavalRobert AsiimwePatricia TusiimeMary A. NassejjeLeo KinyeraLemi RobinMaureen NayebareLuiz G. C. SantosMarina Fernández-GarcíaLucas SwistunowJosé M. AlgarínJohn StairsMichael HansenRonald AmodoiAndrew WebbJoshua HarperSteven J. SchiffJohnes ObungolochJoseba Alonsohttp://arxiv.org/abs/2511.18898v1Measuring thermal contact resistances between metallic rods using laser spot heating and infrared thermography. Part 12025-11-24T08:53:56ZEstimation of thermal contact resistances between cylinders can be achieved using heating on the cross sections by a laser spot and measurement of the temperature response by IR thermography. This type of measurement makes it possible to characterise contacts in clusters of cylinders to simulate clusters of grains, or the properties of fibrous media in the transverse direction or, under certain conditions, to detect emerging thermal resistances (cracks perpendicular to the observation plane) by IR thermography. Here, the thermal model is simplified because the temperature field in relaxation on either side of the resistance can be considered isothermal with a separation of transfers in the plane and along the thickness. The mathematical model is then analytical (relaxation of a linear system), and the processing of the temperature field can be inversed thanks to the consideration of the logarithm of matrices, useful when studying the propagation of measurement noise. The method proposed in the case of two or three cylinders is a first step and a validation for applications to the study of more complex media (large number of cylinders, granular media).2025-11-24T08:53:56ZQuantitative InfraRed Thermography Journal, 2025, pp.1-11Thomas LahensI2MAlain SommierI2MMarie-Marthe GrozI2M, INSIS - CNRSJean-Christophe BatsaleI2Mhttp://arxiv.org/abs/2511.18741v1On the Appropriateness of Linear Stress Recovery in Biomechanical Analysis of Abdominal Aortic Aneurysm2025-11-24T04:10:50ZAbdominal aortic aneurysm (AAA) wall stress is a candidate rupture risk marker but is typically computed from single-phase images without known cardiac phase. Linear stress recovery methods, which solve a single geometrically linear equilibrium problem on the imaged, already-loaded geometry, have been validated for static stress estimation, but their robustness to unknown imaging phase remains unexplored. We investigated whether imaging phase materially biases 99th percentile stress recovered linearly, and whether linear recovery agrees with non-linear analysis under matched loads. Two patient-specific AAAs from a public 4D-CTA cohort (Case 1: 5.5% strain; Case 2: 4.5% strain) were analyzed. For each, we analyzed diastolic and synthetic systolic geometry, the latter generated by warping the diastolic mesh via displacements from non-linear hyperelastic analysis. Linear stresses were recovered on both geometries under systolic pressure and compared via 99th-percentile maximum principal stress, stress distributions, and 3D stress differential contours. Linear stresses under pulse pressure were compared against non-linear stresses. 99th-percentile stresses from linear recovery on diastolic vs synthetic systolic geometries under systolic pressure differed by 8.6% (Case 1) and 3.5% (Case 2), within segmentation uncertainty. 99th-percentile stresses from linear recovery and non-linear analysis under pulse pressure agreed closely: 0% difference (Case 1) and 1.1% (Case 2), with nearly identical distributions. These findings support linear stress recovery for patient-specific AAA analysis in clinical settings with static single-phase imaging, offering a computationally efficient alternative without compromising accuracy or requiring patient-specific wall properties.2025-11-24T04:10:50Z16 Pages, 13 Figures, Computational Biomechanics for Medicine XXAlastair CatlinMostafa JamshidianAdam WittekKarol Millerhttp://arxiv.org/abs/2511.20695v1A Brief History of Digital Twin Technology2025-11-24T02:03:55ZEmerging from NASA's spacecraft simulations in the 1960s, digital twin technology has advanced through industrial adoption to spark a healthcare transformation. A digital twin is a dynamic, data-driven virtual counterpart of a physical system, continuously updated through real-time data streams and capable of bidirectional interaction. In medicine, digital twin integrates imaging, biosensors, and computational models to generate patient-specific simulations that support diagnosis, treatment planning, and drug development. Representative applications include cardiac digital twin for predicting arrhythmia treatment outcomes, oncology digital twin for tracking tumor progression and optimizing radiotherapy, and pharmacological digital twin for accelerating drug discovery. Despite rapid progress, major challenges, including interoperability, data privacy, and model fidelity, continue to limit widespread clinical integration. Emerging solutions such as explainable AI, federated learning, and harmonized regulatory frameworks offer promising pathways forward. Looking ahead, advances in multi-organ digital twin, genomics integration, and ethical governance will be essential to ensure that digital twin shifts healthcare from reactive treatment to predictive, preventive, and truly personalized medicine.2025-11-24T02:03:55Z21 pages, 1 figure, 1 tablePET Clin. 2026 Jan;21(1):143-151. Epub 2025 Oct 21Yunqi ZhangKuangyu ShiBiao Li10.1016/j.cpet.2025.09.006http://arxiv.org/abs/2511.18547v1Towards Integrated Clinical-Computational Nuclear Medicine2025-11-23T17:31:52ZThe field of Clinical-Computational Nuclear Medicine is rapidly advancing, fueled by AI, tracer kinetic modeling, radiomics, and integrated informatics. These technologies improve imaging quality, automate lesion detection, and enable personalized radiopharmaceutical therapy through physiologically based pharmacokinetic (PBPK) modeling and voxel-level dosimetry. Workflow automation and Natural Language Processing (NLP) further enhance operational efficiency. However, successful implementation and adoption of these tools require clinical oversight to ensure accuracy, interpretability, and patient safety. This paper highlights key computational innovations and emphasizes the critical role of clinician-guided evaluation in shaping the future of precision imaging and therapy.2025-11-23T17:31:52ZFaraz FarhadiShadi A. EsfahaniFereshteh YousefiriziMonica LuoPedro Esquinas FernandezArkadiusz SitekHamid SabetBabak SabouryArman RahmimPedram Heidarihttp://arxiv.org/abs/2511.18320v1Comprehensive Multimodal and Multiscale Analysis of Alzheimer Disease in 5xFAD Mice: Optical Spectroscopies, TEM, Neuropathological, and Behavioral Investigations2025-11-23T07:21:50ZAlzheimer disease (AD) is considered one of the leading causes of death in the United States, and there is no effective cure for it. Understanding the neuropathological mechanisms underlying AD is essential for identifying early, reliable biomarkers and developing effective therapies. In this paper, we report on a comprehensive multimodal study of AD pathology using the 5xFAD mouse model. We employed light-scattering techniques, Partial Wave Spectroscopy (PWS) and Inverse Participation Ratio (IPR), to detect nanoscale structural alterations in brain tissues, nuclear components, and mitochondria. To support the light-scattering experiments, behavior, and histopathological studies were conducted. These analyses revealed significant increases in structural heterogeneity and mass density fluctuations in the brains of 5xFAD mice compared with Non-transgenic controls. Behavioral assessment demonstrated memory impairment in 5xFAD mice, reflected by a reduced recognition index. Histopathological analysis further revealed increased amyloid beta plaques and microglia activation in the hippocampus and cortex of 5xFAD mice compared with Non-transgenic controls. An increase in structural disorder within brain tissues can be attributed to higher mass density fluctuations, likely arising from macromolecular rearrangement driven by amyloid beta aggregation and neuroinflammatory responses as the disease progresses. Our findings suggest that PWS and IPR-derived metrics provide sensitive biophysical indicators of early cellular and subcellular disruption, offering potential as quantitative biomarkers for the detection and progression of AD.2025-11-23T07:21:50Z27 pages, 9 figuresDhruvil SolankiIshmael ApachigawoSazzad KhanSantanu MaityFatemah AlharthiSamia NasimMohammad Alizadeh PoshtiriFnu SweetyJiangfeng XiaoMohammad Moshahid KhanPrabhakar Pradhanhttp://arxiv.org/abs/2511.17787v1Data-Driven Predictive Modeling of Microfluidic Cancer Cell Separation Using a Deterministic Lateral Displacement Device2025-11-21T21:08:34ZDeterministic Lateral Displacement (DLD) devices are widely used in microfluidics for label-free, size-based separation of particles and cells, with particular promise in isolating circulating tumor cells (CTCs) for early cancer diagnostics. This study focuses on the optimization of DLD design parameters, such as row shift fraction, post size, and gap distance, to enhance the selective isolation of lung cancer cells based on their physical properties. To overcome the challenges of rare CTC detection and reduce reliance on computationally intensive simulations, machine learning models including gradient boosting, k-nearest neighbors, random forest, and multilayer perceptron (MLP) regressors are employed. Trained on a large, numerically validated dataset, these models predict particle trajectories and identify optimal device configurations, enabling high-throughput and cost-effective DLD design. Beyond trajectory prediction, the models aid in isolating critical design variables, offering a systematic, data-driven framework for automated DLD optimization. This integrative approach advances the development of scalable and precise microfluidic systems for cancer diagnostics, contributing to the broader goals of early detection and personalized medicine.2025-11-21T21:08:34ZAccepted to IEEE International Conference on Data Mining (ICDM) 2025 REU SymposiumElizabeth ChenAndrew LeeTanbir SarowarXiaolin Chenhttp://arxiv.org/abs/2511.13628v2Smooth Total variation Regularization for Interference Detection and Elimination (STRIDE) for MRI2025-11-21T19:01:24ZMRI is increasingly desired to function near electronic devices that emit potentially dynamic electromagnetic interference (EMI). To accommodate for this, we propose the STRIDE method, which improves on previous external-sensor-based EMI removal methods by exploiting inherent MR image smoothness in its total variation. STRIDE measures data from both EMI detectors and primary MR imaging coils, transforms this data into the image domain, and for each column of the resulting image array, combines and subtracts data from the EMI detectors in a way that optimizes for total-variation smoothness. Performance was tested on phantom and in-vivo datasets with a 0.5T scanner. STRIDE resulted in visually better EMI removal, higher temporal SNR, larger EMI removal percentage, and lower RMSE than standard implementations. STRIDE is a robust technique that leverages inherent MR image properties to provide improved EMI removal performance over standard algorithms, particularly for time-varying noise sources.2025-11-17T17:39:35ZAlexander MertensDiego MartinezAmgad LoukaYing YangChad HarrisIan Connellhttp://arxiv.org/abs/2511.17158v1Exploring the added value of pretherapeutic MR descriptors in predicting breast cancer pathologic complete response to neoadjuvant chemotherapy2025-11-21T11:25:32ZObjectives: To evaluate the association between pretreatment MRI descriptors and breast cancer (BC) pathological complete response (pCR) to neoadjuvant chemotherapy (NAC). Materials \& Methods: Patients with BC treated by NAC with a breast MRI between 2016 and 2020 were included in this retrospective observational single-center study. MR studies were described using the standardized BI-RADS and breast edema score on T2-weighted MRI. Univariable and multivariable logistic regression analyses were performed to assess variables association with pCR according to residual cancer burden. Random forest classifiers were trained to predict pCR on a random split including 70% of the database and were validated on the remaining cases. Results: Among 129 BC, 59 (46%) achieved pCR after NAC (luminal (n=7/37, 19%), triple negative (TN) (n=30/55, 55%), HER2+ (n=22/37, 59%). Clinical and biological items associated with pCR were BC subtype (p<0.001), T stage 0/I/II (p=0.008), higher Ki67 (p=0.005) and higher tumor-infiltrating lymphocytes levels (p=0.016). Univariate analysis showed that the following MRI features, oval or round shape (p=0.047), unifocality (p=0.026), non-spiculated margins (p=0.018), no associated non-mass enhancement (NME) (p = 0.024) and a lower MRI size (p = 0.031) were significantly associated with pCR. Unifocality and non-spiculated margins remained independently associated with pCR at multivariable analysis. Adding significant MRI features to clinicobiological variables in random forest classifiers significantly increased sensitivity (0.67 versus 0.62), specificity (0.69 versus 0.67) and precision (0.71 versus 0.67) for pCR prediction. Conclusion: Non-spiculated margins and unifocality are independently associated with pCR and can increase models performance to predict BC response to NAC. Clinical Relevance Statement: A multimodal approach integrating pretreatment MRI features with clinicobiological predictors, including TILs, could be employed to develop machine learning models for identifying patients at risk of non-response. This may enable consideration of alternative therapeutic strategies to optimize treatment outcomes2025-11-21T11:25:32ZEuropean Radiology, 2023, 33 (11), pp.8142-8154Caroline MalhaireLITOFatine SelhaneMarie-Judith Saint-MartinVincent CockenpotPia AklEnora LaasAudrey BellesoeurCatherine Ala EddineMelodie Bereby-KahaneJulie ManceauDelphine Sebbag-SfezJean-Yves PiergaFabien ReyalAnne Vincent-SalomonHerve BrisseFrederique Frouinhttp://arxiv.org/abs/2511.16878v1Double-Profile Intersection (DoPIo) Ultrasound: Pointwise Shear Elasticity Estimation using Paired Confocal Displacement Profiles2025-11-21T01:02:56ZCurrent acoustic radiation force (ARF) based methods for quantifying tissue elasticity primarily rely on shear wave propagation. However, their spatial resolution is limited by the need for spatial averaging, and their accuracy is affected by shear wave guidance, out of plane reflections, and geometric dispersion, which reduce their applicability in mechanically complex tissues. This study introduces a novel technique called Double Profile Intersection (DoPIo) ultrasound, which enables pointwise estimation of shear elastic modulus within the region of ARF excitation by leveraging the scatterer shearing rate. This rate is inferred by tracking ARF induced displacement using two tracking beams with different lateral widths. The wider beam captures scatterers located outside the ARF excitation region that begin to displace as shearing propagates. The time at which the two resulting displacement profiles intersect is mapped to shear elastic modulus using an empirically derived model based on finite element simulations. In silico, DoPIo estimated shear elastic modulus with a median error of -0.02 kPa and a median absolute deviation of 1.98 kPa in elastic materials up to 35 kPa. Experimental validation in vitro and ex vivo demonstrated that DoPIo reliably distinguished softer regions from stiffer ones, and its modulus estimates remained consistent across varying ARF push amplitudes, provided sufficient displacement estimation signal to noise ratio. DoPIo offers a feasible approach for high resolution, on axis shear elasticity estimation and holds promise as a quantitative biomarker that is independent of ARF amplitude.2025-11-21T01:02:56ZThis work has been submitted to the IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control Society (OJ-UFFC) for possible publicationKeita YokoyamaMurad HossainSabiq MuhtadiCaterina Gallippihttp://arxiv.org/abs/2507.06337v3Integrated Open-Source Framework for Simulation of Transcatheter Pulmonary Valves in Native Right Ventricular Outflow Tracts2025-11-20T23:36:13ZBackground - Pulmonary insufficiency is a consequence of transannular patch repair in Tetralogy of Fallot (ToF), leading to late morbidity and mortality. Transcatheter native outflow tract pulmonary valve replacement (TPVR) has become common, but assessment of patient candidacy and selection of the optimal device remains challenging. We demonstrate an integrated open-source workflow for simulation of TPVR in image-derived models to inform device selection.
Methods - Machine learning-based segmentation of CT scans was implemented to define the right ventricular outflow tract (RVOT). A custom workflow for device positioning and pre-compression was implemented in SlicerHeart. Resulting geometries were exported to FEBio for simulation. Visualization of results and quantification were performed using custom metrics implemented in SlicerHeart and FEBio.
Results - RVOT model creation and device placement could be completed in under 1 minute. Virtual device placement using FE simulations visually mimicked actual device placement and allowed quantification of vessel strain, stress, and contact area. Regions of higher strain and stress were observed at the proximal and distal end locations of the TPVs where the devices impinge the RVOT wall. No other consistent trends were observed across simulations. The observed variability in mechanical metrics across RVOTS, stents, and locations in the RVOT highlights that no single device performs optimally in all anatomies, thereby reinforcing the need for simulation-based patient-specific assessment.
Conclusions - This study demonstrates the feasibility of a novel open-source workflow for the rapid simulation of TPVR which with further refinement may inform assessment of patient candidacy and optimal device selection.2025-07-08T18:56:15Z27 pages, 7 figures, 2 videos, Preprint submitted to Engineering with ComputersChristopher N. ZelonisJalaj MaheshwariWensi WuSteve A. MaasSeda AslanKyle SunderlandStephen ChingAshley KoludaYuval Barak-CorrenNicolas ManginePatricia M. SabinAndras LassoDevin W. LaurenceChristian HerzMatthew J. GillespieJeffrey A. WeissMatthew A. Jolleyhttp://arxiv.org/abs/2511.16775v1A Respiratory Motion Analysis for Guiding Stereotactic Arrhythmia Radiotherapy Motion Management2025-11-20T20:07:26ZStereotactic Arrhythmia Radiotherapy (STAR) treats ventricular tachycardia (VT) but requires internal target volume (ITV) expansions to compensate for cardiorespiratory motion. Current clinical r4DCT imaging methods are limited, and the reconstructed r4DCTs suffer from unmanaged cardiac motion artifacts that affect the quantitative assessment of respiratory motion. A groupwise surface-to-surface deformable image registration (DIR) algorithm, named gCGF, was developed. A novel principal component filtering (PCF) mechanism and a spatial smoothing mechanism were developed and incorporated into gCGF to iteratively register heart contours from an average respiratory-phase CT to ten r4DCT phases while removing random cardiac motion from the cyclic respiratory motion. The performance of the groupwise DIR was quantitatively validated using 8 digital phantoms with simulated cardiac artifacts. An ablation study was conducted to compare gCGF to another comparable state-of-the-art groupwise DIR method. gCGF was applied to r4DCTs of 20 STAR patients to analyze the respiratory motion of the heart. Validation on digital phantoms showed that gCGF achieved a mean target registration error of 0.63+-0.51 mm while successfully achieving phase smoothness and reducing cardiac motion artifacts. Among all STAR patients, the heart's maximum and mean respiratory motion magnitudes ranged from 3.6 to 7.9 mm and 1.0 mm to 2.6 mm. The peak-to-peak motion range was from 6.2 to 14.7 mm. For VT targets, the max and mean motion magnitude ranges were 3.0 to 6.7 mm and 0.8 to 2.9 mm, respectively. The peak-to-peak range was from 4.7 to 11.8 mm. Significant dominance of the first principal component of the motion direction was observed (p = 0).2025-11-20T20:07:26ZYuhao WangYao HaoHongyu AnH Michael GachClifford RobinsonPhillip S CuculichDeshan Yang