https://arxiv.org/api/4KNI2thAh5LFrmNf1BoLoflajx02026-06-24T05:51:24Z900167515http://arxiv.org/abs/2511.22779v1Accelerating mesh-based Monte Carlo simulations using contemporary graphics ray-tracing hardware2025-11-27T22:10:54ZSignificance: Monte Carlo (MC) methods are the gold-standard for modeling light-tissue interactions due to their accuracy. Mesh-based MC (MMC) offers enhanced precision for complex tissue structures using tetrahedral mesh models. Despite significant speedups achieved on graphics processing units (GPUs), MMC performance remains hindered by the computational cost of frequent ray-boundary intersection tests.
Aim: We propose a highly accelerated MMC algorithm, RT-MMC, that leverages the hardware-accelerated ray traversal and intersection capabilities of ray-tracing cores (RT-cores) on modern GPUs.
Approach: Implemented using NVIDIA's OptiX platform, RT-MMC extends graphics ray-tracing pipelines towards volumetric ray-tracing in turbid media, eliminating the need for challenging tetrahedral mesh generation while delivering significant speed improvements through hardware acceleration. It also intrinsically supports wide-field sources without complex mesh retesselation.
Results: RT-MMC demonstrates excellent agreement with traditional software-ray-tracing MMC algorithms while achieving 1.5x to 4.5x speedups across multiple GPU architectures. These performance gains significantly enhance the practicality of MMC for routine simulations.
Conclusion: Migration from software- to hardware-based ray-tracing not only greatly simplifies MMC simulation workflows, but also results in significant speedups that are expected to increase further as ray-tracing hardware rapidly gains adoption. Adoption of graphics ray-tracing pipelines in quantitative MMC simulations enables leveraging of emerging hardware resources and benefits a wide range of biophotonics applications.2025-11-27T22:10:54ZShijie YanDouglas DwyerDavid R. KaeliQianqian Fanghttp://arxiv.org/abs/2511.22716v1The Biologically Effective Particle Number Ratio (BPNR): a new framework to quantify the therapeutic window in SFRT and other modalities2025-11-27T19:01:10ZSpatially Fractionated Radiation Therapy (SFRT) produces highly heterogeneous dose distributions, for which conventional metrics such as peak, valley, or average dose can yield ambiguous or inconsistent estimates of therapeutic window changes. These dose descriptors are not uniquely linked to biological outcome, complicating comparisons between modalities. We introduce the Biologically Effective Particle Number Ratio (BPNR), a model-independent and outcome-based framework that quantifies therapeutic window changes using directly measurable delivery quantities rather than spatial dose metrics. BPNR is defined as the ratio of total particle numbers (proportional to monitor units, MU) required to reach specified levels of tumor control probability (TCP) and normal tissue complication probability (NTCP). The relative BPNR (RBPNR) compares therapeutic windows across modalities and avoids ambiguities of spatial dose averaging by relying solely on biological endpoints. As an illustration, we apply the framework to preclinical proton minibeam radiotherapy (pMBRT) versus conventional proton therapy. The absence of normal tissue complications at the highest tested MU in the pMBRT arm yields an RBPNR > 1.4, indicating a widened therapeutic window. The BPNR/RBPNR methodology provides a concise, experimentally grounded, and modality-agnostic way to quantify therapeutic window changes, with potential applications across SFRT, FLASH, high-LET radiation, and combination therapies.2025-11-27T19:01:10Z2 figuresNiels BasslerGiuseppe SchettinoHugo PalmansThomas FriedrichKelvin Ng Wei SiangEmanuele ScifoniFardous Reazhttp://arxiv.org/abs/2512.07882v1Referenceless Proton Resonance Frequency Thermometry Using Deep Learning with Self-Attention2025-11-27T18:36:14ZBackground: Accurate proton resonance frequency (PRF) MR thermometry is essential for monitoring temperature rise during thermal ablation with high intensity focused ultrasound (FUS). Conventional referenceless methods such as complex field estimation (CFE) and phase finite difference (PFD) tend to exhibit errors when susceptibility-induced phase discontinuities occur at tissue interfaces.2025-11-27T18:36:14ZYueran ZhaoChang-Sheng MeiNathan J. McDannoldShenyan ZongGuofeng Shenhttp://arxiv.org/abs/2211.00316v10Hessian-free Ray-Born Inversion for Quantitative Ultrasound Tomography of Weakly Heterogeneous Media2025-11-27T11:22:31ZThis study presents a frequency-domain, Hessian-free ray-Born inversion method for quantitative ultrasound tomography, extending the author's previous Hessian-based approach. Both approaches model acoustic wave propagation using a ray-based approximation of the Green's function in smoothly varying heterogeneous media, and perform the inversion iteratively in the frequency domain, progressing from low to high frequencies. In the earlier method, each frequency subproblem was solved through iterative inversion of the Hessian matrix, a process that not only increased computational cost but also made the update steps more sensitive to noise. The present work addresses these limitations by diagonalizing the Hessian matrix through a specific weighting scheme, which enables a single-step inversion for each frequency subproblem. This reformulation reduces the computational expense by approximately an order of magnitude relative to the Hessian-based approach. The weighting scheme also functions as a smoothing regularizer that is intrinsically embedded within the forward operator, thereby balancing computational efficiency and spatial resolution while producing robust reconstructions less sensitive to noise. Furthermore, for approximating the geometrical portion of the amplitude, this study introduces a paraxial ray-tracing system, further enhancing computational efficiency and accuracy. The inversion approach proposed in the present study has enabled the first successful translation of acoustic inverse scattering methods to a clinical setting.2022-11-01T07:49:11ZResults demonstrating the implementation of the image-reconstruction approach proposed in this study on in-vitro and in-vivo ultrasound datasets released by the University of Rochester Medical Center are reported in the reference [4] and are also included in the GitHub repository [3]Ashkan Javaherianhttp://arxiv.org/abs/2511.22131v1Autonomous labeling of surgical resection margins using a foundation model2025-11-27T05:52:42ZAssessing resection margins is central to pathological specimen evaluation and has profound implications for patient outcomes. Current practice employs physical inking, which is applied variably, and cautery artifacts can obscure the true margin on histological sections. We present a virtual inking network (VIN) that autonomously localizes the surgical cut surface on whole-slide images, reducing reliance on inks and standardizing margin-focused review. VIN uses a frozen foundation model as the feature extractor and a compact two-layer multilayer perceptron trained for patch-level classification of cautery-consistent features. The dataset comprised 120 hematoxylin and eosin (H&E) stained slides from 12 human tonsil tissue blocks, resulting in ~2 TB of uncompressed raw image data, where a board-certified pathologist provided boundary annotations. In blind testing with 20 slides from previously unseen blocks, VIN produced coherent margin overlays that qualitatively aligned with expert annotations across serial sections. Quantitatively, region-level accuracy was ~73.3% across the test set, with errors largely confined to limited areas that did not disrupt continuity of the whole-slide margin map. These results indicate that VIN captures cautery-related histomorphology and can provide a reproducible, ink-free margin delineation suitable for integration into routine digital pathology workflows and for downstream measurement of margin distances.2025-11-27T05:52:42Z20 Pages, 5 FiguresXilin YangMusa AydinYuhong LuSahan Yoruc SelcukBijie BaiYijie ZhangAndrew BirkelandKatjana EhrlichJulien BecLaura MarcuNir PillarAydogan Ozcanhttp://arxiv.org/abs/2511.22094v1GACELLE: GPU-accelerated tools for model parameter estimation and image reconstruction2025-11-27T04:30:29ZQuantitative MRI (qMRI) offers tissue-specific biomarkers that can be tracked over time or compared across populations; however, its adoption in clinical research is hindered by significant computational demands of parameter estimation. Images acquired at high spatial resolution or requiring fitting multiple parameters often require lengthy processing time, constraining their use in routine pipelines and slowing methodological innovation and clinical translation.
We present GACELLE, an open source, GPU-accelerated framework for high-throughput qMRI analysis. GACELLE provides a stochastic gradient descent optimiser and a stochastic sampler in MATLAB, enabling fast parameter mapping, improved estimation robustness via spatial regularisation, and uncertainty quantification. GACELLE prioritises accessibility: users only need to provide a forward signal model, while GACELLE's backend manages computational parallelisation, automatic parameter updates, and memory-batching. The stochastic solver performs fully vectorised Markov chain Monte Carlo with identical likelihood on CPU and GPU, ensuring reproducibility across hardware.
Benchmarking demonstrates up to 451-fold acceleration for the stochastic gradient descent solver and 14,380-fold acceleration for stochastic sampling compared to CPU-based estimation, without compromising accuracy. We demonstrated GACELLE's versatility on three representative qMRI models and on an image reconstruction task. Across these applications, GACELLE improves parameter precision, enhances test-retest reproducibility, and reduces noise in quantitative maps.
By combining speed, usability and flexibility, GACELLE provides a generalisable optimisation framework for medical image analysis. It lowers the computational barrier for qMRI, paving the way for reproducible biomarker development, large-scale imaging studies, and clinical translation.2025-11-27T04:30:29ZKwok-Shing ChanDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United StatesHarvard Medical School, Boston, MA, United StatesHansol LeeDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United StatesHarvard Medical School, Boston, MA, United StatesYixin MaDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United StatesHarvard Medical School, Boston, MA, United StatesBerkin BilgicDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United StatesHarvard Medical School, Boston, MA, United StatesSusie Y. HuangDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United StatesHarvard Medical School, Boston, MA, United StatesHong-Hsi LeeDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United StatesHarvard Medical School, Boston, MA, United StatesJosé P. MarquesDonders Institute for Brain, Cognition and Behaviour, Radboud University, Nijmegen, The Netherlandshttp://arxiv.org/abs/2511.15963v2PySERA: Open-Source Standardized Python Library for Automated, Scalable, and Reproducible Handcrafted and Deep Radiomics2025-11-26T22:00:55ZRadiomics enables the extraction of quantitative biomarkers from medical images for precision modeling, but reproducibility and scalability remain limited due to heterogeneous software implementations and incomplete adherence to standards. Existing tools also lack unified support for deep learning based radiomics. To address these limitations, we introduce PySERA, an open source, Python native, standardized radiomics framework designed for automation, reproducibility, and seamless AI integration. PySERA reimplements the MATLAB based SERA platform within a modular, object oriented architecture and computes 557 features, including 487 Image Biomarker Standardization Initiative (IBSI) compliant features, 10 moment invariant descriptors, and 60 diagnostic features, together with deep learning radiomics embeddings from pretrained networks such as ResNet50, DenseNet121, and VGG16. The framework provides standardized preprocessing, including resampling, discretization, and normalization, multi format image input and output, adaptive memory management, and a parallel multicores extraction engine. PySERA integrates natively with major machine learning ecosystems including scikit learn, PyTorch, TensorFlow, MONAI and others. In IBSI benchmarks, PySERA achieved more than 94 percent reproducibility and outperformed PyRadiomics while closely matching MITK. Across eight public datasets, it achieved predictive accuracies ranging from 0.54 to 0.87, consistently exceeding PyRadiomics. PySERA unifies handcrafted and deep learning radiomics in a transparent, scalable, and extensible Python framework, establishing a robust foundation for reproducible, AI ready imaging research.2025-11-20T01:33:18Z20 pages, 7 Figures, and 5 tablesMohammad R. SalmanpourAmir Hossein PouriaSirwan BarichinYasaman SalehiSonya FalahatiIsaac ShiriMehrdad OveisiArman Rahmimhttp://arxiv.org/abs/2511.21833v1Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging2025-11-26T19:04:04ZObjective: Hyper-clutter artifacts (HCA), arising from strong tissue reflections or physiological motion, present persistent challenges in ultrafast ultrasound Doppler imaging, often obscuring surrounding small vessel flow signals, especially in fascial regions such as the renal capsule. This study proposes U-profile-based decluttering (UPBD), a robust and computationally efficient method that exploits singular value decomposition (SVD)-derived spatial singular vectors to suppress HCA in ultrafast Doppler imaging. Methods: UPBD analyzes intensity profile of each pixel along the singular-order dimension of the SVD-derived left singular vectors U. A pixel-wise clutter-energy ratio is computed to derive a spatially adaptive declutter weighting map, which is applied to the SVD-filtered flow signals. Results: UPBD was evaluated on multiple in vivo datasets. Quantitative assessments based on contrast-to-noise ratio (CNR) and contrast-to-tissue ratio (CTR) demonstrated significant improvements over conventional SVD filtering. For example, UPBD enhanced CTR from 7.3 dB to 21.7 dB in contrast-free pig kidney, 17.8 dB to 42.1 dB in contrast-enhanced pig kidney, 8.2 dB to 32.8 dB in human kidney, and -4.9 dB to 3.7 dB in 3D human liver. Conclusion: The proposed UPBD method effectively suppresses HCA while preserving blood flow signals with minimal extra computational cost and no need for extensive parameter tuning. Significance: UPBD serves as a lightweight, easily integrated post-processing method that enhances HCA suppression, enabling broader application of SVD-based ultrafast Doppler imaging.2025-11-26T19:04:04ZLijie HuangJingyi YinJingke ZhangU-Wai LokRyan M. DeRuiterKaipeng JiYanzhe ZhaoTao WuJames D. KrierXiang-yang ZhuAndrew J. BentallAndrew D. RuleThomas D. AtwellLilach O. LermanShigao ChenChengwu Huanghttp://arxiv.org/abs/2511.21647v1Fast 3D Ultrasound Localization Microscopy via Projection-based Processing Framework2025-11-26T18:19:00ZThree-dimensional ultrasound localization microscopy (ULM) enables comprehensive visualization of the vasculature, thereby improving diagnostic reliability. Nevertheless, its clinical translation remains challenging, as the exponential growth in voxel count for full 3D reconstruction imposes heavy computational demands and extensive post-processing time. In this row-column array (RCA)-based 3D in vivo pig kidney ULM study, we reformulate each step of the full 3D ULM pipeline, including beamforming, clutter filtering, motion estimation, microbubble separation and localization into a series of computational-efficient 2D operations, substantially reducing the number of voxels to be processed while maintaining comparable accuracy. The proposed framework reconstructs each 0.75-s ensemble acquired at frame rate of 400 Hz, covering a 25*27.4*27.4 mm3 volume, in 0.52 s (70% of the acquisition time) on a single RTX A6000 Ada GPU, while maintaining ULM image quality comparable to conventional 3D processing. Quantitatively, it achieves a structural similarity index (SSIM) of 0.93 between density maps and a voxel-wise velocity agreement with slope of 0.93 and R2 = 0.88, closely matching conventional 3D results, and for the first time, demonstrating potential for real-time feedback during scanning, which could improve robustness, reduce operator dependence and accelerate clinical workflows.2025-11-26T18:19:00ZJingke ZhangJingyi YinU-Wai LokLijie HuangRyan M. DeRuiterTao WuKaipeng JiYanzhe ZhaoJames D. KrierXiang-yang ZhuLilach O. LermanChengwu HuangShigao Chenhttp://arxiv.org/abs/2511.21484v1A Dynamic Anti-Equinus Orthosis with Electromyography Sensor for Neuromuscular Rehabilitation2025-11-26T15:18:15ZThe equinus foot is a neuromuscular condition that affects ankle dorsiflexion, impairing gait and reducing quality of life. This study presents EquiSay, a dynamic anti-equinus orthosis equipped with an anterior elastic tension system and an electromyography (EMG) sensor to quantify muscle activation, particularly of the tibialis anterior. EquiSay provides dynamic support that improves foot posture and natural movement while enabling real-time neuromuscular monitoring.
To address the limited availability of EMG data, the system incorporates a U-Net based model for generating synthetic EMG signals and a predictive framework for automatic calibration of minimum activation thresholds. Experimental results show improved dorsiflexion, increased patient satisfaction, and valuable clinical insights for rehabilitation planning. These findings highlight the potential of EquiSay as an assistive tool and as a platform for future AI-enhanced developments.2025-11-26T15:18:15Zin Spanish language, Prototype development and evaluation study. 12 pages, 6 figuresManuel Terradillos PereaOlga Alonso GonzalezCristina Soguero RuizDavid Gutierrezhttp://arxiv.org/abs/2511.21344v1Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom2025-11-26T12:50:02ZProton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatment planning. Spatiotemporal Emission Reconstruction from Prompt-Gamma Timing (SER-PGT) is a promising method that provides insights into both particle range and stopping power, whose calculation would normally require knowledge about patient tissue properties that cannot be directly measured. We present the first experimental results using a 226.9 MeV synchrotron-proton beam impinging on a homogeneous phantom at a sub-clinical intensity (2 - 4 x 10^7 pps). SER-PGT uses data from a multi-detector setup: a thin and segmented Low Gain Avalanche Diode for proton detection and Lanthanum Bromide-based crystals for photon detection. The estimated stopping power profile showed an 8% +- 3% average error compared to NIST PSTAR values, and 2% +- 2% deviation relative to water at 100 MeV. Range assessment in a phantom with a 4 cm air-gap successfully identified the range shift with a 3 mm standard deviation. These results demonstrate the feasibility of using SER-PGT to recover both range and stopping power information through particle kinematics and PGT measurements.2025-11-26T12:50:02Z15 pages, 6 figuresJulius WernerFrancesco PennazioPiergiorgio CerelloElisa FiorinaSimona GiordanengoFelix Mas MilianAlessio MereghettiFranco MostardiMarco PulliaSahar RanjbarRoberto SacchiAnna VignatiMagdalena RafecasVeronica Ferrerohttp://arxiv.org/abs/2511.21167v1Strategic Development of a Hydrogen Supply Chain in Corsica: a Multi-criteria Analysis2025-11-26T08:28:11ZA multi-objective framework for hydrogen supply chain (HSC) planning is developed for island contexts, incorporating Mixed-Integer Linear Programming (MILP) over multiple time periods. The model minimizes total system cost, greenhouse gas (GHG) emissions, and a risk index criteria. The case study of Corsica is considered, using Geographic Information Systems (GIS) for spatial analysis and infrastructure locating. The 2050 future design of the HSC is determined including site selection, capacity sizing, and technology choices. The proposed m-TOPSIS-based multi objectives solution shows a decentralized infrastructure with a levelized cost of hydrogen of ___6.55/kg, and greenhouse gas emissions under 2 kgCO___e/kg H___. The study also integrates water availability and tourism-induced demand variation as key drivers of energy planning in insular regions.2025-11-26T08:28:11Z2025 IEEE Conference on Power Electronics and Renewable Energy (CPERE), Sep 2025, Aswan, France. pp.1-5Tchougoune Moustapha MaiLGCMohamed HajajjiLGCCatherine Azzaro-PantelLGCMaude Chin ChoiChristian Cristofarihttp://arxiv.org/abs/2511.20864v1Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET2025-11-25T21:25:25ZBismuth germanate (BGO) is gaining renewed attention as a viable material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET) detectors. While single-crystal studies have demonstrated excellent timing resolution by leveraging prompt Cherenkov photons, practical detector modules based on pixelated arrays introduce a high prevalence of inter-crystal scattering (InterCS) events, complicating timing accuracy. In this study, we experimentally investigated the impact of InterCS on BGO Cherenkov timing using a dual-pixel detector coupled to a segmented SiPM readout. Events were classified into full-energy deposition (FED; primary crystal 511 keV absorption), InterCS, and penetration types via energy-weighted positioning and validated using GATE simulations, which also revealed that over 25% of the experimentally identified full-energy events involved intra-crystal scatter (IntraCS). For InterCS events, the optimal timestamp selection was achieved by choosing the earlier of the two timestamps, yielding a coincidence timing resolution of 221 ps FWHM (831 ps FWTM)-markedly worse than the 184 ps (603 ps FWTM) obtained for FED events. Furthermore, prompt photon yield was found to decrease measurably due to energy splitting: InterCS events averaged 4.73 detected photons in the first 1 ns, compared to 5.76 for FED events. These results emphasize the importance of incorporating time-aware, per-pixel timestamping strategies in pixelated BGO TOF-PET systems to maintain optimal timing performance in the presence of scatter.2025-11-25T21:25:25ZMinseok YiDaehee LeeAlberto GolaStefano MerziMichele PennaSimon R. CherryJae Sung LeeSun Il Kwonhttp://arxiv.org/abs/2511.20472v1Wide Area Surface Dosimetry with Conformal Scintillator Array for External Beam Radiotherapy2025-11-25T16:34:59ZBackground: In vivo dosimetry is essential for treatment verification in modern radiotherapy, but existing techniques are limited by spatiotemporal resolution and performance on non-uniform anatomy. Scintillation imaging dosimetry shows potential to address several of these limitations. Here, translation to conventional photon external beam radiotherapy was examined using a novel wide-area imaging and sensing technique.
Methods: A modular scintillator array was combined with a dual-camera stereovision system for 3D localization and a clinical Cherenkov imaging system for optical scintillation detection. Water equivalent thickness, dose linearity, repetition rate stability, and angular dependence were characterized. Field edge detection was evaluated against radiochromic film using gamma analysis. System reproducibility was tested with consecutive deliveries simulating contralateral breast monitoring during whole-breast tangential radiotherapy.
Results: The array showed high dose linearity across the tested range, minimal beam perturbation, and consistent response within 5% across all available LINAC repetition rates. Dose-normalized scintillation varied within 5% over clinically relevant gantry angles, and camera angle corrections compensated for non-Lambertian emission. Field edge detection agreed closely with film, with a 99.98% gamma pass rate (3%/3 mm). Inter-delivery reproducibility of +/-1 cGy demonstrated robust system performance.
Conclusion: The conformable scintillator array imaging system provides spatially resolved, dynamic surface dosimetry with minimal workflow impact. Its ability to generate continuous dose maps across complex anatomical surfaces, while maintaining angular correction, addresses key limitations of current in vivo dosimetry and shows strong potential for clinical integration where wide-area surface dosimetry is required.2025-11-25T16:34:59Z19 pages, 7 figuresRoman VasyltsivAllison L. MatousNatasha MulengaMegan A. ClarkBrian W. PogueDavid J. GladstoneLesley A. JarvisPetr Bruzahttp://arxiv.org/abs/2511.20358v1Manganese-based macrocyclic chelates as novel MRI contrast agents: In vivo imaging in a porcine model2025-11-25T14:38:50ZObjectives: Mn-based MRI contrast agents (MBCAs) have recently been proposed as alternatives to the currently used class of Gd-chelates. Unlike Gd, Mn is an endogenous paramagnetic metal with known biochemical pathways in the human body for excretion and metal regulation, which may alleviate the raised concerns about the safety of existing GBCAs. The aim of this study was to investigate the distribution, kinetics and image enhancement properties of a class of novel Mn-based macrocyclic chelates in a porcine model. Methods: Macrocyclic MBCAs, AH114608, GEH300017 and GEH200486, were tested and compared to gadoterate meglumine. Twelve female adult pigs were divided into four groups (n=3 for each CA). At 3 T MRI, T1 relaxometry analysis were measured longitudinally in multiple organs at five timepoints 30 minutes apart. CA kinetics was estimated from analysis of plasma CA concentrations by ICP-OES. Results: All four CAs exhibited T1-enhancing properties in the blood pool with GEH200486 having the largest increase in T1 relaxation rate (R1), GEH300017 and gadoterate meglumine having similar R1 increase and AH114608 a lower peak R1 change. A persistent increase in liver, kidney and myocardium R1 was observed with AH114608. To a lesser extent, a persistent increase of liver enhancement was also observed in T1-weighted images for GEH300017 and GEH200486 compared to gadoterate meglumine. All four CAs had similar bi-exponential plasma kinetics characterized by a rapid distribution phase and a slower elimination phase. Discussion: We have identified MBCA candidates with predominantly renal clearance and comparable efficacy in terms of vascular T1 relaxation, and comparable to the reference GBCA. The T1-enhancing properties of these novel Mn macrocyclic CAs can be used with routine clinical protocols and could be potentially utilised as an alternative to GBCAs for contrast-enhanced MRI procedures.2025-11-25T14:38:50Z15 pages, 8 figures and 3 tablesPål B. MarthinsenTuva R. HopeWibeke NordhøyDeirdre B. CassidyAdrian P. L. SmithPaul M. EvansAtle Bjørnerud