https://arxiv.org/api/5gT2qvrMIF9Gcj5wKWLeYuIikCk2026-06-24T04:55:53Z900166015http://arxiv.org/abs/2512.04787v12bNIRS: a portable, multi-distance, broadband oximeter and cytochrome-c-oxidase monitoring system for in vivo applications2025-12-04T13:34:35ZConventional near-infrared spectroscopy (NIRS) instruments typically employ 2-3 wavelengths for monitoring tissue haemodynamics. However, the use of broadband illumination (hundreds of wavelengths) unlocks also the targeting of tissue metabolism by exploiting the wide differential-redox peak of absorption of cytochrome-c-oxidase (CCO). For this purpose, we present here a novel, broadband (780-900nm), multi-distance NIRS system, called 2bNIRS. Compact and portable (20 x 30 x 40 cm3), 2bNIRS was validated using a dynamic, optical phantom con-taining blood and yeast, and benchmarked against a multi-wavelength time-domain NIRS (TD-NIRS) system. Validation confirmed its accuracy in tracking haemody-namic and metabolic changes, with superior oximetry performance achieved via our BRUNO algorithm, which integrates broadband spectral fitting with spatially-re-solved analysis. Preliminary in vivo, human applications demonstrated 2bNIRS ap-plicability to monitoring both muscle tissue, during arm cuff occlusions, and the brain, during frontal cortex activation.2025-12-04T13:34:35ZLuca GiannoniArchie BarracloughChiara CarnatiFrederic LangeIlias Tachtsidishttp://arxiv.org/abs/2504.14033v8Adaptive Diffusion Models for Sparse-View Motion-Corrected Head Cone-beam CT2025-12-04T12:33:45ZCone-beam computed tomography (CBCT) is an imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion, especially under sparse-view settings used to reduce dose, which can result in severe image artifacts. In this work, we propose a novel framework combining joint reconstruction and motion estimation (JRM) with an adaptive diffusion model (ADM) that simultaneously addresses motion compensation and sparse-view reconstruction in head CBCT. Leveraging recent advances in diffusion-based generative models, our method integrates a wavelet-domain diffusion prior into an iterative reconstruction pipeline to guide the solution toward anatomically plausible volumes while estimating rigid motion parameters in a blind fashion. We evaluate our method on simulated motion-affected CBCT data derived from real clinical computed tomography (CT) volumes. Experimental results demonstrate that JRM- ADM achieves consistent quantitative improvements over both traditional and learning-based baselines. In highly undersampled cases, JRM-ADM improves peak signal-to-noise ratio (PSNR) by more than 4 dB and structural similarity index measure (SSIM) by 0.10 compared to the baseline motion-corrected (MC) reconstruction method. These results highlight the potential of our approach to enable motion-robust, low-dose CBCT imaging, paving the way for improved clinical viability. The project page is available at https://antoinedepaepe.github.io/jrm-adm-io/.2025-04-18T18:50:16Z12 pages, 10 figures, 2 tablesAntoine De PaepeAlexandre BousseClémentine Phung-NgocYouness MellakDimitris Visvikis10.1109/TRPMS.2025.3637124http://arxiv.org/abs/2512.04662v1Spectral micro-CT for quantitative analysis of calcification in fibrocartilage2025-12-04T10:50:17ZThis work introduces a quantitative method for assessing calcification in fibrocartilage using spectral micro-computed tomography ($μ$CT). Tissue samples of hip acetabular labrum from patients with osteoarthritis and femoroacetabular impingement were imaged with a laboratory-based spectral $μ$CT system equipped with a small-pixel photon-counting detector. The detector operated with two energy thresholds, allowing the simultaneous acquisition of two CT datasets at different X-ray energies. A material decomposition algorithm accounting for the system's spectral response was applied to separate calcium- and water-like components, yielding three-dimensional visualization and quantification of calcified regions within intact paraffin-embedded samples. Unlike the conventional method for calcification assessment based on histology, this spectral μCT approach offers volumetric quantification of calcium structures without physical sectioning or staining. The method achieved a voxel size of 20 $μ$m for samples up to ~3 cm, with a calcium detection threshold of ~0.3 g/cm$^3$ for structures down to 50 $μ$m. Quantification accuracy was estimated to be 5% by using a calibration phantom. Further comparison with histology demonstrated the correct localization of calcium spatial distributions and a match in the calcium crystal deposition score by providing non-destructive, quantitative 3D calcium maps of preserved tissue samples. This technique complements histology and could enhance the characterization of pathological fibrocartilage calcification in hip joint disorders.2025-12-04T10:50:17ZVittoria MazziniPaolo CardarelliAndrew L. CoathupEleonora OlivottoFrancesco GrassiEnrico TassinariSimone VelarditaAngelo TaibiLuca Brombalhttp://arxiv.org/abs/2512.04616v1Standard audiogram classification from loudness scaling data using unsupervised, supervised, and explainable machine learning techniques2025-12-04T09:46:11ZTo address the calibration and procedural challenges inherent in remote audiogram assessment for rehabilitative audiology, this study investigated whether calibration-independent adaptive categorical loudness scaling (ACALOS) data can be used to approximate individual audiograms by classifying listeners into standard Bisgaard audiogram types using machine learning. Three classes of machine learning approaches - unsupervised, supervised, and explainable - were evaluated. Principal component analysis (PCA) was performed to extract the first two principal components, which together explained more than 50 percent of the variance. Seven supervised multi-class classifiers were trained and compared, alongside unsupervised and explainable methods. Model development and evaluation used a large auditory reference database containing ACALOS data (N = 847). The PCA factor map showed substantial overlap between listeners, indicating that cleanly separating participants into six Bisgaard classes based solely on their loudness patterns is challenging. Nevertheless, the models demonstrated reasonable classification performance, with logistic regression achieving the highest accuracy among supervised approaches. These findings demonstrate that machine learning models can predict standard Bisgaard audiogram types, within certain limits, from calibration-independent loudness perception data, supporting potential applications in remote or resource-limited settings without requiring a traditional audiogram.2025-12-04T09:46:11ZChen XuLena Schell-MajoorBirger Kollmeier10.1080/14992027.2026.2642765http://arxiv.org/abs/2512.03224v1Modeling and simulation of electrodiffusion in dense reconstructions of cerebral tissue2025-12-02T21:02:43ZExcitable tissue is fundamental to brain function, yet its study is complicated by extreme morphological complexity and the physiological processes governing its dynamics. Consequently, detailed computational modeling of this tissue represents a formidable task, requiring both efficient numerical methods and robust implementations. Meanwhile, efficient and robust methods for image segmentation and meshing are needed to provide realistic geometries for which numerical solutions are tractable. Here, we present a computational framework that models electrodiffusion in excitable cerebral tissue, together with realistic geometries generated from electron microscopy data. To demonstrate a possible application of the framework, we simulate electrodiffusive dynamics in cerebral tissue during neuronal activity. Our results and findings highlight the numerical and computational challenges associated with modeling and simulation of electrodiffusion and other multiphysics in dense reconstructions of cerebral tissue.2025-12-02T21:02:43ZHalvor HerlyngMarius CausemannGaute T. EinevollAda J. EllingsrudGeir HalnesMarie E. Rogneshttp://arxiv.org/abs/2512.02988v1Alternative winding patterns for twisted solenoid coils with improved characteristics for TRASE MRI2025-12-02T18:03:31ZTransmit Array Spatial Encoding (TRASE) is an MRI technique in which spatial encoding is achieved using phase gradients of the B1 field. This approach offers potential advantages such as hardware simplicity and reduced acoustic noise. In this study, we present an assessment of various winding patterns for twisted solenoid phase-gradient coils, including the simple twisted solenoid (with and without return wire), a double-wound twisted solenoid, and a discrete-loop twisted solenoid. We analyze the magnetic field uniformity and phase linearity of these configurations using Biot-Savart simulations. Our results show that both the double-wound and discrete loop designs offer similar improvements over the simple twisted solenoid with return wire. The discrete loop pattern requires less wire than the double-wound version, making it the preferred option for practical coil construction and operation in a TRASE MRI system.2025-12-02T18:03:31Z22 pages, 12 figuresJournal of Magnetic Resonance 388 (2026) 108068Nahid GhomimolkarAlexander E. KrosneyChristopher P. Bidinosti10.1016/j.jmr.2026.108068http://arxiv.org/abs/2512.02917v1Maintaining SUV Accuracy in Low-Count PET with PETfectior: A Deep Learning Denoising Solution2025-12-02T16:35:14ZBackground: Diagnostic PET image quality depends on the administered activity and acquisition time. However, minimizing these variables is desirable to reduce patient radiation exposure and radiopharmaceutical costs. PETfectior is an artificial intelligence-based software that processes PET scans and increases signal-to-noise ratio, obtaining high-quality images from low-count-rate images. We perform an initial clinical validation of PETfectior on images acquired with half of the counting statistics required to meet the most recent EANM quantitative standards for 18F-FDG PET, evaluating lesions detectability, quantitative performance and image quality.
Materials and methods: 258 patients referred for 18F-FDG PET/CT were prospectively included. The standard-of-care scans (100% scans) were acquired and reconstructed according to EARL standards 2. Half-counting-statistics versions were generated from list-mode data and processed with PETfecftior (50%+PETfectior scans). All oncologic lesions were segmented on both PET/CT versions, manually or automatically, and lesions detectability was evaluated. The SUVmax of the lesions was measured and the quantitative concordance of 50%+PETfectior and 100% images was evaluated. Subjective image quality was visually assessed by two experienced physicians.
Results: 1649 lesions were detected in a total of 198 studies. The 50%+PETfectior images showed high sensitivity for lesion detection (99.9%) and only 1 false positive was detected. The SUVmax measured in 100% and 50%+PETfectior images agreed within 12.5% (95% limits of agreement), with a bias of -1.01%. Image quality of the 50%+PETfectior images was rated equal to or better than the standard-of-care images.
Conclusion: PETfectior can safely be used in clinical practice at half counting statistics, with high sensitivity and specificity, low quantitative bias and high subjective image quality.2025-12-02T16:35:14ZYamila Rotstein HabarnauNicolás BustosPaola CoronaChristian GonzálezSonia TraversoFederico MatorraFrancisco FunesJuan Martín GirautLaura PelegrinaGabriel BrunoMauro Namíashttp://arxiv.org/abs/2410.13348v2Technical Note: Vendor-Specific Approach for Standardized Uptake Value Calculation2025-12-01T14:49:32ZThe Standardized Uptake Value (SUV) is a critical metric in positron emission tomography (PET) imaging, used to assess metabolic activity. However, calculating SUV from DICOM files presents challenges due to vendor-specific DICOM attributes and variations in the encoding of radiotracer accumulation times. This technical note introduces a robust, vendor-specific SUV calculation strategy that addresses inconsistencies in current methodologies. We also integrate this strategy into an open-source software solution, Z-Rad, capable of converting raw PET DICOM data into body-weight normalized SUV NIfTI files.
Our SUV calculation strategy was developed by reviewing DICOM conformance statements from GE, Philips, and Siemens. Validation was conducted using real-world PET datasets, and the proposed strategy was compared to existing software solutions.
Our SUV calculation approach demonstrated improved accuracy, particularly in resolving time-related discrepancies in the studied data. Our analysis also identified inconsistencies in the SUV calculation methods used by popular commercial and open-source software solutions, which do not fully account for vendor-specific DICOM attributes and PET image acquisition times. These limitations resulted in errors in SUV estimation reaching 33\% when comparing our strategy to studied software.
The proposed vendor-specific SUV calculation strategy significantly enhances accuracy in PET imaging by addressing key inconsistencies caused by variations in DICOM attributes and image acquisition times across different vendors. This method effectively reduces SUV calculation errors and has been integrated into an open-source software, Z-Rad.2024-10-17T09:00:10ZMaksym FritsakHubert S. GabryśPreethi MohanMatthias GuckenbergerStephanie Tanadini-Langhttp://arxiv.org/abs/2508.20218v2Velocity Spectrum Imaging using velocity encoding preparation pulses2025-12-01T14:16:40ZPurpose: The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity. As such, it is completely non-invasive and requires no contrast injections.
Methods: The technique consists of acquiring a series of images preceded by preparatory RF pulses that encode velocity information, analogously to k-space encoding. The velocity distribution can be decoded via the Fourier transform. We demonstrate its use on a simple flow phantom with known flow characteristics. We demonstrate the technique on the brains of five human participants from whom we collected the velocity distribution along each of the three laboratory axes.
Results: Velocity distribution measurements on simple phantoms yielded velocity distributions consistent with theory. Human velocity spectra identified specific anatomical features at different velocity bins. The largest fraction of spins was in the lowest velocity bands. Movement in the CSF spaces could be clearly identified at different velocity bands.
Conclusion: Velocity Spectrum Imaging has great potential as a tool to study the movement of fluids in the human body without contrast agents. In addition to a useful tool for validating computational fluid dynamic models in vivo, it can be used to study the complex movement of water in the glymphatic system and its involvement in neurodegenerative disorders. However, further development is needed to probe the velocity spectrum in the ultra-low velocity regime of the perivascular spaces.2025-08-27T18:54:35Z32 pages, 7 figures, 5 supplementary figures, submitted to Magn. Res. Med , on Aug. 2025 - acceptedLuis Hernandez-GarciaAlberto L. VazquezDoug C. Nollhttp://arxiv.org/abs/2512.01458v1Sulfate phantoms to mimic NIR photoacoustic response of whole blood at selected oxygen saturations2025-12-01T09:44:44ZThis paper presents a practical guide to prepare inorganic solutions that mimic the photoacoustic properties of whole blood at specific levels of oxygenation in the range of 700 nm to 850 nm, both in terms of optical absorption properties and the Gr{ü}neisen coefficient. The goal is to provide aqueous solutions that can be injected in tissue-mimicking imaging phantoms to test the sensitivity and spectral capabilities of photoacoustic imaging systems operating at multiple wavelengths to estimate blood oxygenation.2025-12-01T09:44:44ZLéa DavenetLIBArthur BillonLIBJacques BattagliaLIBS Lori BridalLIBJérôme GateauLIBhttp://arxiv.org/abs/2511.11274v2Polarization-Sensitive Module for Optical Coherence Tomography Instruments2025-11-30T22:36:16ZPolarization-sensitive optical coherence tomography (PS-OCT) extends OCT by analyzing the polarization states of backscattered light to quantify tissue birefringence. However, conventional implementations require polarization-diverse detection and are therefore incompatible with most commercial OCT systems. As a result, PS-OCT has largely remained restricted to specialized research groups, limiting its broader scientific and clinical use. Here, we present a modular PS-OCT framework that integrates with a standard spectral-domain OCT platform through a detachable rotating achromatic half-wave plate in the sample arm. This waveplate modulates both incident and reflected polarization states. Three or more repeated measurements at distinct waveplate orientations enable reconstruction of the sample's round-trip Jones matrix and the corresponding polarization properties. To mitigate random phase variations between repeated measurements, we introduce a retarder-constrained phase optimization strategy. We validate the framework with imaging of birefringent phantoms and the human retina in vivo, demonstrating reliable reconstruction of retardance and optic axis orientation. This approach requires only minimal hardware modification and is readily deployable on mainstream OCT systems. Lowering technical barriers paves the way for rapid and widespread deployment of PS-OCT across diverse biomedical applications in both research and clinical environments.2025-11-14T13:09:37Z9 pages, 8 figuresPo-Yi LeeChuan-Bor ChuehMilen ShishkovTai-Ang WangHsiang-Chieh LeeTeresa ChenBrett E. BoumaMartin Villigerhttp://arxiv.org/abs/2511.23331v1Optimization and application of ultra-high field preclinical high-resolution and 3D 1H-MRSI using compressed sensing2025-11-28T16:35:15ZProton magnetic resonance spectroscopic imaging (1H-MRSI) at ultra-high field has seen an increase in usage in the preclinical field. Challenges related to long acquisition time and low concentration of brain metabolites in the rodent brain have led to the development and application of acceleration schemes for 3D-1H-MRSI, such the undersampling technique Compressed Sensing (CS). This present study aims to explore the CS tool in the context of preclinical in vivo application in order to achieve high-resolution MRSI acquisition in both 2D with an in-plane increase and 3D/multi-slice acquisition with through-plane. The parameters are explored to achieve the highest acceleration possible as a way to make 3D as time efficient as possible. Results of the parameter study showed that an acceleration factor (AF) of 4 was possible with the right sampling size of the core at the center of the k-space. With this specific set, higher matrix size resulting in sub 1 μL nominal voxel size was explored with 2D-FID-MRSI and 9 supplementary phase-encoding/slices were added to achieve 3D-FID-MRSI. The spectral quality and the metabolic maps were accurate enough in the comparison with the non-accelerated 2D-FID-MRSI, within the slice of interest. Issues related with the point spread function (PSF) were noted throughout the different usage of CS. Our work presents a robust and effective protocol to achieve 3D-1H-MRSI using CS in order to reach an acquisition time below the 30 minutes bar, with minimal technical limitations and high-quality acquisition.2025-11-28T16:35:15ZBrayan AlvesThanh Phong LêGianna NossaTan Toi PhanAlessio SivigliaBernard LanzWolfgang BognerAntoine KlauserBernhard StrasserCristina Cudalbuhttp://arxiv.org/abs/2511.23274v1Simultaneous Image Quality Improvement and Artefacts Correction in Accelerated MRI2025-11-28T15:25:24ZMR data are acquired in the frequency domain, known as k-space. Acquiring high-quality and high-resolution MR images can be time-consuming, posing a significant challenge when multiple sequences providing complementary contrast information are needed or when the patient is unable to remain in the scanner for an extended period of time. Reducing k-space measurements is a strategy to speed up acquisition, but often leads to reduced quality in reconstructed images. Additionally, in real-world MRI, both under-sampled and full-sampled images are prone to artefacts, and correcting these artefacts is crucial for maintaining diagnostic accuracy. Deep learning methods have been proposed to restore image quality from under-sampled data, while others focused on the correction of artefacts that result from the noise or motion. No approach has however been proposed so far that addresses both acceleration and artefacts correction, limiting the performance of these models when these degradation factors occur simultaneously. To address this gap, we present a method for recovering high-quality images from under-sampled data with simultaneously correction for noise and motion artefact called USArt (Under-Sampling and Artifact correction model). Customized for 2D brain anatomical images acquired with Cartesian sampling, USArt employs a dual sub-model approach. The results demonstrate remarkable increase of signal-to-noise ratio (SNR) and contrast in the images restored. Various under-sampling strategies and degradation levels were explored, with the gradient under-sampling strategy yielding the best outcomes. We achieved up to 5x acceleration and simultaneously artefacts correction without significant degradation, showcasing the model's robustness in real-world settings.2025-11-28T15:25:24ZGeorgia KanliDaniele PerloSelma BoudissaRadovan JirikOlivier Keunen10.1007/978-3-031-73284-3_23http://arxiv.org/abs/2511.23135v1Strategies to Minimize Out-of-Distribution Effects in Data-Driven MRS Quantification2025-11-28T12:33:05ZThis study systematically compared data-driven and model-based strategies for metabolite quantification in magnetic resonance spectroscopy (MRS), focusing on resilience to out-of-distribution (OoD) effects and the balance between accuracy, robustness, and generalizability. A neural network designed for MRS quantification was trained using three distinct strategies: supervised regression, self-supervised learning, and test-time adaptation. These were compared against model-based fitting tools. Experiments combined large-scale simulated data, designed to probe metabolite concentration extrapolation and signal variability, with 1H single-voxel 7T in-vivo human brain spectra. In simulations, supervised learning achieved high accuracy for spectra similar to those in the training distribution, but showed marked degradation when extrapolated beyond the training distribution. Test-time adaptation proved more resilient to OoD effects, while self-supervised learning achieved intermediate performance. In-vivo experiments showed larger variance across the methods (data-driven and model-based) due to domain shift. Across all strategies, overlapping metabolites and baseline variability remained persistent challenges. While strong performance can be achieved by data-driven methods for MRS metabolite quantification, their reliability is contingent on careful consideration of the training distribution and potential OoD effects. When such conditions in the target distribution cannot be anticipated, test-time adaptation strategies ensure consistency between the quantification, the data, and the model, enabling reliable data-driven MRS pipelines.2025-11-28T12:33:05ZSubmitted to MRMJulian P. MerkoferAntonia KaiserAnouk SchranteeOliver J. Gurney-ChampionRuud J. G. van Slounhttp://arxiv.org/abs/2511.22879v1Design and Construction of a Dedicated Radiolucent 8-element Flexible Radiofrequency (RF) Torso Coil for the 1.0T Australian MRI-Linac System2025-11-28T05:00:42ZMagnetic resonance imaging-guided linear accelerators (MRI-Linacs) are an emerging treatment technology that enable online soft-tissue visualisation and adaptive radiotherapy. The Australian 1.0 T MRI-Linac employs a fixed, inline beamline, with treatment angles achieved via patient couch rotation, and currently relies on a radiolucent whole-body radiofrequency (RF) coil. However, the large coil-patient separation limits signal-to-noise ratio (SNR) and constrains the fast imaging required for real-time tumour tracking. Here, we show the design and validation of a dedicated, flexible 8-element receive-only RF torso array tailored to the geometry and beam access requirements of the Australian MRI-Linac. Electromagnetic simulations, bench measurements, and phantom imaging demonstrate approximately three-fold SNR improvement at the centre and eight-fold improvement at superficial regions compared with the whole-body coil. In vivo abdominal imaging confirms enhanced anatomical detail and sharper tissue boundaries, and the increased SNR enables parallel imaging with GRAPPA acceleration factors up to three without severe artefacts. Dosimetry measurements and dynamic beam-on noise analysis confirm that the coil array is effectively radiolucent, with dose differences below 1% and no measurable degradation in image noise. This work demonstrates a practical RF solution for accelerated, high-SNR imaging compatible with patient rotation and beam delivery on the Australian MRI-Linac.2025-11-28T05:00:42ZMingyan LiEwald WeberDavid E. J. WaddingtonShanshan ShanPaul LiuBin DongPaul J. KeallFeng LiuStuart Crozier