https://arxiv.org/api/e49tFeOydNmutIn01NBPmn/Vif8 2026-06-23T02:48:50Z 8994 645 15 http://arxiv.org/abs/2512.06712v1 Optimal experimental design with k-space data: application to inverse hemodynamics 2025-12-07T08:01:50Z Subject-specific cardiovascular models rely on parameter estimation using measurements such as 4D Flow MRI data. However, acquiring high-resolution, high-fidelity functional flow data is costly and taxing for the patient. As a result, there is growing interest in using highly undersampled MRI data to reduce acquisition time and thus the cost, while maximizing the information gain from the data. Examples of such recent work include inverse problems to estimate boundary conditions of aortic blood flow from highly undersampled k-space data. The undersampled data is selected based on a predefined sampling mask which can significantly influences the performance and the quality of the solution of the inverse problem. While there are many established sampling patterns to collect undersampled data, it remains unclear how to select the best sampling pattern for a given set of inference parameters. In this paper we propose an Optimal Experimental Design (OED) framework for MRI measurements in k-space, aiming to find optimal masks for estimating specific parameters directly from k-space. As OED is typically applied to sensor placement problems in spatial locations, this is, to our knowledge, the first time the technique is used in this context. We demonstrate that the masks optimized by employing OED consistently outperform conventional sampling patterns in terms of parameter estimation accuracy and variance, facilitating a speed-up of 10x of the acquisition time while maintaining accuracy. 2025-12-07T08:01:50Z Miriam Löcke Ahmed Attia Dariusz Ucínski Cristóbal Bertoglio http://arxiv.org/abs/2511.03287v2 Structural Stress as a Predictor of the Rate and Spatial Location of Aortic Growth in Uncomplicated Type B Aortic Dissection 2025-12-06T22:21:42Z Accurate prediction of aortic expansion in uncomplicated type B aortic dissection (TBAD) can help identify patients who may benefit from timely thoracic endovascular aortic repair. This study investigates associations between biomechanical predictors derived from reduced-order fluid-structure interaction (FSI) analysis and aortic growth outcomes. Baseline and follow-up CT images from 30 patients with uncomplicated TBAD were obtained. For each patient, a reduced-order FSI analysis using the forward penalty stress computation method was performed on the baseline geometry. Aortic growth was quantified by registering baseline and follow-up surfaces using nonrigid registration. Mixed-effects linear and logistic regression analyses were performed to assess relationships between structural stress, wall shear stress (WSS), pressure and growth rate while accounting for inter-patient variability. Group comparison analyses were performed to evaluate spatial distributions of these biomechanical variables along the dissected aorta between patient groups categorized by optimal medical therapy (OMT) and aortic growth outcomes. Linear regression revealed a positive association between structural stress and aortic growth rate (p = 0.0003) and a negative association for WSS (p = 0.0227). Logistic regression yielded area under the receiver operator characteristic curve (AUCs) of 0.7414, 0.5953, 0.4991, and 0.6845 for structural stress, WSS, pressure, and aortic diameter, respectively. Group comparisons showed significant regional differences in structural stress, but not in diameter, WSS, or pressure, between groups defined by aortic growth and OMT outcomes. These results indicate that structural stress is a promising predictor of both the rate and location of aortic growth in uncomplicated TBAD, which supports its use in risk stratification models to identify patients at higher risk of TBAD progression. 2025-11-05T08:41:44Z Yuhang Du Department of Mechanical Engineering, Texas Tech University, Lubbock, TX Yuxuan Wu Mercer University School of Medicine, Macon, GA Hannah L. Cebull Department of Radiology & Imaging Science, Emory University, Atlanta, GA Bangquan Liao Department of Mechanical Engineering, Texas Tech University, Lubbock, TX Rishika Agarwal The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA Alan Meraz Department of Mechanical Engineering, Texas Tech University, Lubbock, TX Hai Dong Division of Cardiothoracic Surgery, Department of Surgery, Emory University School of Medicine, Atlanta, GA Asanish Kalyanasundaram Aortic Institute at Yale-New Haven Hospital, Yale University School of Medicine, New Haven, CT John N. Oshinski Department of Radiology & Imaging Science, Emory University, Atlanta, GA The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA Rudolph L. Gleason The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA John A. Elefteriades Aortic Institute at Yale-New Haven Hospital, Yale University School of Medicine, New Haven, CT Bradley G. Leshnower Division of Cardiothoracic Surgery, Department of Surgery, Emory University School of Medicine, Atlanta, GA Minliang Liu Department of Mechanical Engineering, Texas Tech University, Lubbock, TX http://arxiv.org/abs/2512.06326v1 Alterations of brain tissue structural complexity and disorder in Parkinson disease (PD): Fractal, multifractal, fractal transformation, and disorder strength analyses 2025-12-06T07:01:53Z Parkinson disease (PD) is marked by progressive neurodegeneration, yet early and subtle structural alterations in brain tissue remain difficult to detect with conventional imaging and analytical methods. Fractal and multifractal frameworks offer a principled way to quantify complex biological architecture, but their diagnostic utility in PD has been largely unexplored. In this study, we investigated the fractal and multifractal characteristics of human brain tissues to identify structural alterations associated with PD. Alongside conventional fractal and multifractal analysis, we employed a recently developed fractal functional distribution method that transforms distributions into a Gaussian form, thereby enhancing quantification. Using this combined approach, we found notable deviations across multiple distribution metrics in PD samples, offering potential for quantitative staging and diagnostic applications. The multifractal analysis revealed threshold-dependent variations in intensity-based measures, which are linked to the sparsity and heterogeneity of neural tissue and suggestive of potential biomarker value. Additionally, we applied inverse participation ratio (IPR) analysis to assess structural disorder, demonstrating that larger IPR pixel sizes correlate with increased structural complexity during disease progression. These complementary analyses outline a multi-layered quantitative profile of PD-related tissue disruption, offering a foundation for earlier, objective assessment of disease-associated microstructural change. 2025-12-06T07:01:53Z 22 pages, 8 figures Santanu Maity Mousa Alrubayan Mohammad Moshahid Khan Prabhakar Pradhan http://arxiv.org/abs/2512.06237v1 Fast and Robust T1 Mapping Based on a 3D Dual-Echo UTE Sequence (PETALUTE) for SPION Biodistribution Assessment 2025-12-06T01:29:58Z Superparamagnetic iron oxide nanoparticles (SPIONs) such as ferumoxytol are promising theranostic agents detectable with MRI. Relaxation time mapping offers reproducible, quantitative biomarkers of SPION distribution, but conventional methods suffer from susceptibility artifacts, long echo times, and extended scan durations, limiting accurate quantification. This study developed a fast, B1-corrected T1-mapping protocol using PETALUTE, a 3D dual-echo ultrashort-echo MRI sequence with a rosette k-space trajectory and variable flip-angle acquisition for quantitative ferumoxytol imaging. Agarose phantoms containing 0-5000 ppm ferumoxytol were scanned at 7T with PETALUTE and vendor-supplied RARE-VTR. PETALUTE T1 maps were derived from two flip angles (4 deg and 20 deg), and mean R1 values were correlated with ferumoxytol concentration. For in vivo feasibility, mice bearing 4T1 mammary and flank tumors were scanned 24 h post-injection (ferumoxytol: n=2, 40 mg/kg; control: n=1). Regions of interest in muscle and tumors were analyzed to compare T1 and R1 values obtained with both methods. PETALUTE produced positive contrast for all phantom concentrations except 5000 ppm, whereas RARE-VTR did not. PETALUTE demonstrated a significant linear correlation between R1 and ferumoxytol concentration (R=0.975, p<0.01), in contrast to RARE-VTR (R=0.672, p=0.144). In vivo, PETALUTE enabled high-resolution, whole-abdominal imaging in 4 min 19 s. Ferumoxytol-injected mice showed T1 shortening in flank tumors, consistent with iron uptake, and PETALUTE revealed elevated T1 value with preserved T2*-weighted signal in one mammary tumor. PETALUTE-based T1 mapping provides fast, quantitative, positive-contrast ferumoxytol imaging with greater spatial coverage and a wider usable concentration range than conventional RARE-VTR. 2025-12-06T01:29:58Z Zhen Jiang Stephen Sawiak Alexandra Lipka Xin Shen Uzay Emir Ali Özen Mark Chiew Justin Geise Joseph Speth Deng-Yuan Chang Jessica Veenstra Mitchell Gabalski Luis Solorio Gregory Tamer Matthew Scarpelli http://arxiv.org/abs/2512.05615v1 Fate of gadolinium in inflamed mouse brain: Release and phosphate interaction post-contrast agent administration 2025-12-05T10:59:09Z Mounting evidence for markedly increased cerebellar Gd retention under neuroinflammatory conditions after repeated linear gadolinium-based contrast agents (GBCA) administration in vivo, makes necessary a discrimination between Gd retained within the GBCA complex and forms dissociated form the complex and to characterize the chemical environment of the released Gd$^{3+}$. We employed electron paramagnetic resonance (EPR) and electron nuclear double resonance (ENDOR) spectroscopy, which enable direct detection of Gd$^{3+}$ release and evaluation of its molecular surroundings in intact cerebellar tissue from inflamed and non-inflamed brain sections exposed to either linear or macrocyclic GBCAs. The experiments were performed on sub-mm brain samples taken after administration of linear gadopentetate and macrocyclic gadobutrol in vivo in a murine multiple sclerosis model and ex vivo in organotypic hippocampal slice cultures under inflammatory conditions. EPR detected μM range Gd levels in intact cerebellar biopsies and slices and distinguished between complex-bound and released Gd following linear GBCA administration in vivo. In biopsies, we detected by ENDOR phosphorus-containing molecules in the microenvironment of released Gd. Complementary mass spectrometry (MS) and MRI calibration experiments on Gd-spiked homogenized mouse brain tissue were used to assess the relaxation-active fraction of retained Gd evidencing binding to inorganic ligands. Our findings demonstrate inflammation-promoted Gd retention, underscore the importance of integrating in vivo and ex vivo analyses to unravel mechanisms of long-term Gd retention, and suggest that conventional MRI may underestimate the true extent of Gd accumulation, especially under neuroinflammatory conditions. 2025-12-05T10:59:09Z 50 pages (41 main part, 9 supplementary material), 13 figures (6 main part, 7 supplementary material) Lina Anderhalten Nicole Höfer Daria Dymnikova Julia Hahndorf Matthias Taupitz Heike Traub Christian Teutloff Carmen Infante-Duarte Robert Bittl http://arxiv.org/abs/2512.05346v1 Hypothesis-Based Particle Detection for Accurate Nanoparticle Counting and Digital Diagnostics 2025-12-05T01:08:07Z Digital assays represent a shift from traditional diagnostics and enable the precise detection of low-abundance analytes, critical for early disease diagnosis and personalized medicine, through discrete counting of biomolecular reporters. Within this paradigm, we present a particle counting algorithm for nanoparticle based imaging assays, formulated as a multiple-hypothesis statistical test under an explicit image-formation model and evaluated using a penalized likelihood rule. In contrast to thresholding or machine learning methods, this approach requires no training data or empirical parameter tuning, and its outputs remain interpretable through direct links to imaging physics and statistical decision theory. Through numerical simulations we demonstrate robust count accuracy across weak signals, variable backgrounds, magnification changes and moderate PSF mismatch. Particle resolvability tests further reveal characteristic error modes, including under-counting at very small separations and localized over-counting near the resolution limit. Practically, we also confirm the algorithm's utility, through application to experimental dark-field images comprising a nanoparticle-based assay for detection of DNA biomarkers derived from SARS-CoV-2. Statistically significant differences in particle count distributions are observed between control and positive samples. Full count statistics obtained further exhibit consistent over-dispersion, and provide insight into non-specific and target-induced particle aggregation. These results establish our method as a reliable framework for nanoparticle-based detection assays in digital molecular diagnostics. 2025-12-05T01:08:07Z Main text (14 pages, 5 figures, 1 table) and supplementary information (5 pages, 3 figures, 2 tables). Supporting code at https://github.com/Optical-Theory-Group/Hypothesis-Test-Based-Particle-Detection Neil H. Kim Xiao-Liu Chu Joseph B. DeGrandchamp Matthew R. Foreman http://arxiv.org/abs/2512.05329v1 CATNUS: Coordinate-Aware Thalamic Nuclei Segmentation Using T1-Weighted MRI 2025-12-05T00:14:10Z Accurate segmentation of thalamic nuclei from magnetic resonance images is important due to the distinct roles of these nuclei in overall brain function and to their differential involvement in neurological and psychiatric disorders. However, segmentation remains challenging given the small size of many nuclei, limited intrathalamic contrast and image resolution, and inter-subject anatomical variability. In this work, we present CATNUS (Coordinate-Aware Thalamic Nuclei Segmentation), segmenting 13 thalamic nuclei (or nuclear groups) using a 3D U-Net architecture enhanced with coordinate convolution layers, which provide more precise localization of both large and small nuclei. To support broad clinical applicability, we provide pre-trained model variants that can operate on quantitative T1 maps as well as on widely used magnetization-prepared rapid gradient echo (MPRAGE) and fast gray matter acquisition T1 inversion recovery (FGATIR) sequences. We benchmarked CATNUS against established methods, including FreeSurfer, THOMAS and HIPS-THOMAS, demonstrating improved segmentation accuracy and robust test-retest reliability across multiple nuclei. Furthermore, CATNUS demonstrated strong out-of-distribution generalization on traveling-subject datasets spanning multiple scanners, field strengths, and vendors, producing reliable and anatomically coherent segmentations across diverse acquisition conditions. Overall, CATNUS provides an accurate and generalizable solution for thalamic nuclei segmentation, with strong potential to facilitate large-scale neuroimaging studies and support real-world clinical assessment. 2025-12-05T00:14:10Z Anqi Feng Zhangxing Bian Samuel W. Remedios Savannah P. Hays Blake E. Dewey Alexa Colinco Jiachen Zhuo Dan Benjamini Jerry L. Prince http://arxiv.org/abs/2505.07117v2 OPTIKS: Optimized Gradient Properties Through Timing in K-Space 2025-12-04T19:25:57Z A customizable method (OPTIKS) for designing fast trajectory-constrained gradient waveforms with optimized time domain properties was developed. Given a specified multidimensional k-space trajectory, the method optimizes traversal speed (and therefore timing) with position along the trajectory. OPTIKS facilitates optimization of objectives dependent on the time domain gradient waveform and the arc-length domain k-space speed. OPTIKS is applied to design waveforms which limit peripheral nerve stimulation (PNS), minimize mechanical resonance excitation, and reduce acoustic noise. A variety of trajectory examples are presented including spirals, circular echo-planar-imaging, and rosettes. Design performance is evaluated based on duration, standardized PNS models, field measurements, gradient coil back-EMF measurements, and calibrated acoustic measurements. We show reductions in back-EMF of up to 94% and field oscillations up to 91.1%, acoustic noise decreases of up to 9.22 dB, and with efficient use of PNS models speed increases of up to 11.4%. The design method implementation is made available as an open source Python package through GitHub. 2025-05-11T21:02:59Z This work has been accepted for publication in IEEE Transactions on Medical Imaging. Please cite the IEE version at DOI 10.1109/TMI.2025.3639398. GitHub Repo: https://github.com/mamccready/optiks IEEE Transactions on Medical Imaging (2025) Matthew A. McCready Xiaozhi Cao Kawin Setsompop John M. Pauly Adam B. Kerr 10.1109/TMI.2025.3639398 http://arxiv.org/abs/2512.04787v1 2bNIRS: a portable, multi-distance, broadband oximeter and cytochrome-c-oxidase monitoring system for in vivo applications 2025-12-04T13:34:35Z Conventional near-infrared spectroscopy (NIRS) instruments typically employ 2-3 wavelengths for monitoring tissue haemodynamics. However, the use of broadband illumination (hundreds of wavelengths) unlocks also the targeting of tissue metabolism by exploiting the wide differential-redox peak of absorption of cytochrome-c-oxidase (CCO). For this purpose, we present here a novel, broadband (780-900nm), multi-distance NIRS system, called 2bNIRS. Compact and portable (20 x 30 x 40 cm3), 2bNIRS was validated using a dynamic, optical phantom con-taining blood and yeast, and benchmarked against a multi-wavelength time-domain NIRS (TD-NIRS) system. Validation confirmed its accuracy in tracking haemody-namic and metabolic changes, with superior oximetry performance achieved via our BRUNO algorithm, which integrates broadband spectral fitting with spatially-re-solved analysis. Preliminary in vivo, human applications demonstrated 2bNIRS ap-plicability to monitoring both muscle tissue, during arm cuff occlusions, and the brain, during frontal cortex activation. 2025-12-04T13:34:35Z Luca Giannoni Archie Barraclough Chiara Carnati Frederic Lange Ilias Tachtsidis http://arxiv.org/abs/2504.14033v8 Adaptive Diffusion Models for Sparse-View Motion-Corrected Head Cone-beam CT 2025-12-04T12:33:45Z Cone-beam computed tomography (CBCT) is an imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion, especially under sparse-view settings used to reduce dose, which can result in severe image artifacts. In this work, we propose a novel framework combining joint reconstruction and motion estimation (JRM) with an adaptive diffusion model (ADM) that simultaneously addresses motion compensation and sparse-view reconstruction in head CBCT. Leveraging recent advances in diffusion-based generative models, our method integrates a wavelet-domain diffusion prior into an iterative reconstruction pipeline to guide the solution toward anatomically plausible volumes while estimating rigid motion parameters in a blind fashion. We evaluate our method on simulated motion-affected CBCT data derived from real clinical computed tomography (CT) volumes. Experimental results demonstrate that JRM- ADM achieves consistent quantitative improvements over both traditional and learning-based baselines. In highly undersampled cases, JRM-ADM improves peak signal-to-noise ratio (PSNR) by more than 4 dB and structural similarity index measure (SSIM) by 0.10 compared to the baseline motion-corrected (MC) reconstruction method. These results highlight the potential of our approach to enable motion-robust, low-dose CBCT imaging, paving the way for improved clinical viability. The project page is available at https://antoinedepaepe.github.io/jrm-adm-io/. 2025-04-18T18:50:16Z 12 pages, 10 figures, 2 tables Antoine De Paepe Alexandre Bousse Clémentine Phung-Ngoc Youness Mellak Dimitris Visvikis 10.1109/TRPMS.2025.3637124 http://arxiv.org/abs/2512.04662v1 Spectral micro-CT for quantitative analysis of calcification in fibrocartilage 2025-12-04T10:50:17Z This work introduces a quantitative method for assessing calcification in fibrocartilage using spectral micro-computed tomography ($μ$CT). Tissue samples of hip acetabular labrum from patients with osteoarthritis and femoroacetabular impingement were imaged with a laboratory-based spectral $μ$CT system equipped with a small-pixel photon-counting detector. The detector operated with two energy thresholds, allowing the simultaneous acquisition of two CT datasets at different X-ray energies. A material decomposition algorithm accounting for the system's spectral response was applied to separate calcium- and water-like components, yielding three-dimensional visualization and quantification of calcified regions within intact paraffin-embedded samples. Unlike the conventional method for calcification assessment based on histology, this spectral μCT approach offers volumetric quantification of calcium structures without physical sectioning or staining. The method achieved a voxel size of 20 $μ$m for samples up to ~3 cm, with a calcium detection threshold of ~0.3 g/cm$^3$ for structures down to 50 $μ$m. Quantification accuracy was estimated to be 5% by using a calibration phantom. Further comparison with histology demonstrated the correct localization of calcium spatial distributions and a match in the calcium crystal deposition score by providing non-destructive, quantitative 3D calcium maps of preserved tissue samples. This technique complements histology and could enhance the characterization of pathological fibrocartilage calcification in hip joint disorders. 2025-12-04T10:50:17Z Vittoria Mazzini Paolo Cardarelli Andrew L. Coathup Eleonora Olivotto Francesco Grassi Enrico Tassinari Simone Velardita Angelo Taibi Luca Brombal http://arxiv.org/abs/2512.04616v1 Standard audiogram classification from loudness scaling data using unsupervised, supervised, and explainable machine learning techniques 2025-12-04T09:46:11Z To address the calibration and procedural challenges inherent in remote audiogram assessment for rehabilitative audiology, this study investigated whether calibration-independent adaptive categorical loudness scaling (ACALOS) data can be used to approximate individual audiograms by classifying listeners into standard Bisgaard audiogram types using machine learning. Three classes of machine learning approaches - unsupervised, supervised, and explainable - were evaluated. Principal component analysis (PCA) was performed to extract the first two principal components, which together explained more than 50 percent of the variance. Seven supervised multi-class classifiers were trained and compared, alongside unsupervised and explainable methods. Model development and evaluation used a large auditory reference database containing ACALOS data (N = 847). The PCA factor map showed substantial overlap between listeners, indicating that cleanly separating participants into six Bisgaard classes based solely on their loudness patterns is challenging. Nevertheless, the models demonstrated reasonable classification performance, with logistic regression achieving the highest accuracy among supervised approaches. These findings demonstrate that machine learning models can predict standard Bisgaard audiogram types, within certain limits, from calibration-independent loudness perception data, supporting potential applications in remote or resource-limited settings without requiring a traditional audiogram. 2025-12-04T09:46:11Z Chen Xu Lena Schell-Majoor Birger Kollmeier 10.1080/14992027.2026.2642765 http://arxiv.org/abs/2512.03224v1 Modeling and simulation of electrodiffusion in dense reconstructions of cerebral tissue 2025-12-02T21:02:43Z Excitable tissue is fundamental to brain function, yet its study is complicated by extreme morphological complexity and the physiological processes governing its dynamics. Consequently, detailed computational modeling of this tissue represents a formidable task, requiring both efficient numerical methods and robust implementations. Meanwhile, efficient and robust methods for image segmentation and meshing are needed to provide realistic geometries for which numerical solutions are tractable. Here, we present a computational framework that models electrodiffusion in excitable cerebral tissue, together with realistic geometries generated from electron microscopy data. To demonstrate a possible application of the framework, we simulate electrodiffusive dynamics in cerebral tissue during neuronal activity. Our results and findings highlight the numerical and computational challenges associated with modeling and simulation of electrodiffusion and other multiphysics in dense reconstructions of cerebral tissue. 2025-12-02T21:02:43Z Halvor Herlyng Marius Causemann Gaute T. Einevoll Ada J. Ellingsrud Geir Halnes Marie E. Rognes http://arxiv.org/abs/2512.02988v1 Alternative winding patterns for twisted solenoid coils with improved characteristics for TRASE MRI 2025-12-02T18:03:31Z Transmit Array Spatial Encoding (TRASE) is an MRI technique in which spatial encoding is achieved using phase gradients of the B1 field. This approach offers potential advantages such as hardware simplicity and reduced acoustic noise. In this study, we present an assessment of various winding patterns for twisted solenoid phase-gradient coils, including the simple twisted solenoid (with and without return wire), a double-wound twisted solenoid, and a discrete-loop twisted solenoid. We analyze the magnetic field uniformity and phase linearity of these configurations using Biot-Savart simulations. Our results show that both the double-wound and discrete loop designs offer similar improvements over the simple twisted solenoid with return wire. The discrete loop pattern requires less wire than the double-wound version, making it the preferred option for practical coil construction and operation in a TRASE MRI system. 2025-12-02T18:03:31Z 22 pages, 12 figures Journal of Magnetic Resonance 388 (2026) 108068 Nahid Ghomimolkar Alexander E. Krosney Christopher P. Bidinosti 10.1016/j.jmr.2026.108068 http://arxiv.org/abs/2512.02917v1 Maintaining SUV Accuracy in Low-Count PET with PETfectior: A Deep Learning Denoising Solution 2025-12-02T16:35:14Z Background: Diagnostic PET image quality depends on the administered activity and acquisition time. However, minimizing these variables is desirable to reduce patient radiation exposure and radiopharmaceutical costs. PETfectior is an artificial intelligence-based software that processes PET scans and increases signal-to-noise ratio, obtaining high-quality images from low-count-rate images. We perform an initial clinical validation of PETfectior on images acquired with half of the counting statistics required to meet the most recent EANM quantitative standards for 18F-FDG PET, evaluating lesions detectability, quantitative performance and image quality. Materials and methods: 258 patients referred for 18F-FDG PET/CT were prospectively included. The standard-of-care scans (100% scans) were acquired and reconstructed according to EARL standards 2. Half-counting-statistics versions were generated from list-mode data and processed with PETfecftior (50%+PETfectior scans). All oncologic lesions were segmented on both PET/CT versions, manually or automatically, and lesions detectability was evaluated. The SUVmax of the lesions was measured and the quantitative concordance of 50%+PETfectior and 100% images was evaluated. Subjective image quality was visually assessed by two experienced physicians. Results: 1649 lesions were detected in a total of 198 studies. The 50%+PETfectior images showed high sensitivity for lesion detection (99.9%) and only 1 false positive was detected. The SUVmax measured in 100% and 50%+PETfectior images agreed within 12.5% (95% limits of agreement), with a bias of -1.01%. Image quality of the 50%+PETfectior images was rated equal to or better than the standard-of-care images. Conclusion: PETfectior can safely be used in clinical practice at half counting statistics, with high sensitivity and specificity, low quantitative bias and high subjective image quality. 2025-12-02T16:35:14Z Yamila Rotstein Habarnau Nicolás Bustos Paola Corona Christian González Sonia Traverso Federico Matorra Francisco Funes Juan Martín Giraut Laura Pelegrina Gabriel Bruno Mauro Namías