https://arxiv.org/api/vpis+KLcHUfGpc7TMc4AbdRqV8Q2026-06-23T01:59:17Z899263015http://arxiv.org/abs/2512.10555v1Event-sparse stack denoising for 4D-STEM applications2025-12-11T11:39:12ZWe introduce a denoising method for four-dimensional scanning transmission electron microscopy (4D-STEM) that relies on processing local, scan position-independent electron event-sparse data stacks, called event-sparse stack denoising. This method adds an extra time dimension during data collection by recording multiple electron event-sparse diffraction patterns. The resulting datasets are effectively five-dimensional, referred to as locally time-resolved STEM (LTR-STEM). Diffraction data stacks at each scan position are processed using one of two sparsity denoising pipelines: 1) the density-based spatial clustering of applications with noise (DBSCAN) algorithm followed by multi-step persistence thresholding, or 2) sparse principal component analysis (sparse PCA), followed by single-step thresholding. Both methods perform well for diffraction data denoising, as shown by simulated peak signal-to-noise ratio (PSNR) curves, denoised experimental data for virtual imaging, and application-specific denoising for defect detection. PSNR analysis indicates that sparsity-denoised 4D-STEM data reaches the same PSNR as raw data at approximately 16% of the exposure time, demonstrating comparable image quality with a lower dose. In defect detection, a 4.1x increase in sensitivity to relative radial disk shift is observed in the denoised data. Moreover, the LTR-STEM technique may be used to inspect material degradation by tracking changes in diffraction disk intensity, allowing for critical dose estimation and exposure-selective imaging.2025-12-11T11:39:12ZGregory NordahlRebekka KlemmtEspen Drath Bøjesenhttp://arxiv.org/abs/2512.10377v1KRAS G12D protein screening for pancreatic cancer clinical trials using an AlGaN/GaN high electron mobility transistor biosensor2025-12-11T07:41:42ZClinical trials screening KRAS G12D protein for 30 pancreatic ductal adenocarcinoma (PDAC) patients and 30 healthy donors were conducted utilizing an AlGaN/GaN high electron mobility transistor (HEMT) biosensor. All resistance change ratios of PDAC patients are higher than the standard deviation above the mean resistance change ratio obtained from all healthy donors. The results demonstrate the effectiveness of the HEMT biosensor and reveal its potential for early detection of pancreatic cancer with KRAS G12D protein screening.2025-12-11T07:41:42ZSheng-Ting HungDepartment of Physics, National Sun Yat-sen University, Kaohsiung, TaiwanCheng Yan LeeDepartment of Physics, National Sun Yat-sen University, Kaohsiung, TaiwanChen-Yu LienDepartment of Physics, National Sun Yat-sen University, Kaohsiung, TaiwanCheng-Hsuan ChanDepartment of Physics, National Sun Yat-sen University, Kaohsiung, TaiwanYa-Han YangDepartment of Surgery, Kaohsiung Medical University Hospital, Kaohsiung, TaiwanQuark Yungsung ChenIndustry Academia Innovation School, National Yang Ming Chiao Tung University, Hsinchu, TaiwanDepartment of Physics and Texas Center for Superconductivity, University of Houston, Houston, TX, USAKuang-Hung ChengInstitute of Biomedical Sciences, National Sun Yat-sen University, Kaohsiung, TaiwanKung-Kai KuoDepartment of Surgery, Kaohsiung Medical University Hospital, Kaohsiung, TaiwanDepartment of Surgery, E-DA Healthcare Group E-DA Dachang Hospital, Kaohsiung, TaiwanLi-Wei TuDepartment of Physics, National Sun Yat-sen University, Kaohsiung, TaiwanChing-Wen ChangInstitute and Undergraduate Program of Electro-Optical Engineering, National Taiwan Normal University, Taipei, Taiwan10.1109/JSEN.2026.3669133http://arxiv.org/abs/2512.09173v1The choice of viscous or viscoelastic models affects attenuation and velocity determination in simplified skull-mimicking digital phantoms2025-12-09T22:38:10ZSimulation-guided transcranial focused ultrasound therapies rely on estimating skull acoustic properties from pretreatment imaging. Typical clinical resolution (0.5 mm isotropic) cannot resolve bone microstructure, making the acoustic properties underdetermined and sensitive to modeling assumptions. Here, we examine how viscous and viscoelastic models predict changes in attenuation and phase velocity due to microstructure. Using viscous and viscoelastic k-Wave implementations, we simulated transmission of a broadband 625 kHz tone burst (250 kHz-1 MHz) through skull-mimicking digital phantoms. The phantoms contained spherical pores (0.1-1.0 mm diameter) randomly embedded within cortical bone (2.5%-90% porosity). Virtual sensors measured attenuation and phase velocity using a time-distance matrix approach. Both models predict increased attenuation with increasing pore size at a fixed porosity, but differ in the strength and porosity dependence of this relationship. The viscoelastic model generally predicts attenuation peaks at higher porosities than the viscous model. For 1.0 mm pores, the viscous peak (1.98 Np/cm) occurs at 20% porosity, while the viscoelastic peak (2.98 Np/cm) occurs at 70%. Phase velocity decreases with pore size for both models, though the viscoelastic predictions are less sensitive to pore size. These results demonstrate that viscous and viscoelastic models exhibit distinct attenuation and phase-velocity behavior for idealized bone microstructures. While both indicate that microstructure has a strong impact on attenuation, it has a lesser effect on phase velocity for the viscoelastic model compared to the viscous model. This work highlights the importance of acoustic model choice when estimating skull acoustic properties from computed tomography images. Future work will identify which acoustic model best represents ultrasound propagation through skull microstructure.2025-12-09T22:38:10ZSubmitted to Physics in Medicine and BiologySamuel ClinardTaylor WebbHenrik OdéenDennis L. ParkerDouglas A. Christensenhttp://arxiv.org/abs/2507.15078v2PET Image Reconstruction Using Deep Diffusion Image Prior2025-12-09T15:49:40ZDiffusion models have shown great promise in medical image denoising and reconstruction, but their application to Positron Emission Tomography (PET) imaging remains limited by tracer-specific contrast variability and high computational demands. In this work, we proposed an anatomical prior-guided PET image reconstruction method based on diffusion models, inspired by the deep diffusion image prior (DDIP) framework. The proposed method alternated between diffusion sampling and model fine-tuning guided by the PET sinogram, enabling the reconstruction of high-quality images from various PET tracers using a score function pretrained on a dataset of another tracer. To improve computational efficiency, the half-quadratic splitting (HQS) algorithm was adopted to decouple network optimization from iterative PET reconstruction. The proposed method was evaluated using one simulation and two clinical datasets. For the simulation study, a model pretrained on [$^{18}$F]FDG data was tested on [$^{18}$F]FDG data and amyloid-negative PET data to assess out-of-distribution (OOD) performance. For the clinical-data validation, ten low-dose [$^{18}$F]FDG datasets and one [$^{18}$F]Florbetapir dataset were tested on a model pretrained on data from another tracer. Experiment results show that the proposed PET reconstruction method can generalize robustly across tracer distributions and scanner types, providing an efficient and versatile reconstruction framework for low-dose PET imaging.2025-07-20T18:25:29Z11 pages, 12 figuresIEEE Trans. Med. Imaging (2026)Fumio HashimotoKuang Gong10.1109/TMI.2026.3659792http://arxiv.org/abs/2507.21263v2In-vivo 6D heart motion analysis for emerging self-powered cardiac implants2025-12-09T09:29:45ZSelf-powered intracardiac implant devices show great promise for future clinical applications due to their extended operational lifespan and the potential to reduce the need for high-risk repeat surgeries. This study investigates the feasibility of harvesting energy from cardiac motion through in vivo testing of intracardiac devices. Comprehensive three-dimensional translational and rotational cardiac motions are captured in a porcine model using a miniaturized 9-degree-of-freedom motion sensor implanted at six strategic epicardial sites. Kinematic criteria are developed to evaluate the energy harvesting potential of each implant site based on the available kinetic energy, acceleration, and jerk factors. The recorded heart motion signals are analyzed and applied to a conceptual energy harvester proposed to identify the optimal implant site. The results reveal that the left ventricular apex emerges as a preferable site for energy harvesting, particularly at moderate heart rates. These findings offer valuable insights into optimizing self-powered intracardiac implants, reducing dependency on battery replacements, and enhancing long-term patient safety.2025-07-28T18:31:19ZAnnals of Biomedical Engineering (2026)Milad HasaniJohn HuberBenedict KjaergaardTomas ZarembaAlireza RezaniaSam Riahi10.1007/s10439-026-04037-5http://arxiv.org/abs/2512.08014v1Robust External-Beam Calibration of Plastic Scintillation Detectors for In-Vivo Dosimetry in HDR Brachytherapy2025-12-08T20:12:51ZPurpose: HDR brachytherapy is a widely adopted modality for cancer treatment. However, it is not free from error and uncertainty. In-vivo dosimetry (IVD) is the only technique that can confirm correct dose delivery. This study details and validates a calibration method for Plastic Scintillation Detector (PSD), bypassing dose gradient and positioning issues in brachytherapy calibration. Methods: The PRB-0057 PSD (Medscint, Canada) was calibrated, 1x1 mm scintillating fiber coupled to a 20 m Eska GH-4001 clear optical fiber (Mitsubishi Rayon, Japan). The fiber is connected to the Hyperscint-RP200 research platform for signal collection. Hyperspectral calibration was performed at a LINAC with a 6 MV beam, enabling removal of stem effects before brachytherapy measurements. For validation, an Iridium-192 Flexisource (Elekta Brachy, The Netherlands), Sk=29447U, was used in a motorized IBA-Blue-Phantom2 water tank (48x48x41cm3). Dose rates were measured at 10 Hz along the source z-axis at a fixed transverse distance of 1.2+/-0.05 cm in 0.2 cm steps. Relative difference (RD) between measured and TG-43U1 dose rates was assessed. A detailed uncertainty budget was associated with brachytherapy measurements. Results: Comparison shows good agreement with RD around 2.5 $\%$ at 1.2 cm, corresponding to positional uncertainties of <0.15 mm. At greater depths up to 8 cm, RDs increase to about 5 $\%$, mainly due to reduced light yield. Uncertainties depend on the source-detector distance, ranging from 3.81 to 6.39 $\%$ (k=1) over the explored range. Conclusions: Results confirm the PSD calibration effectiveness using a 6MV external beam with hyperspectral technique. Uncertainties close to the source align with positional errors and are dominated by reduced PSD sensitivity at larger distances. The study underlined the intrinsic limitation of IVD in the face of known uncertainties.2025-12-08T20:12:51Z22 pages, 6 figures, To be submitted in Phys. Med. BiolChahrazed GhannoudiMarie-Claude LavalleeBenjamin CoteLuc Beaulieuhttp://arxiv.org/abs/2312.13976v4Anatomical basis of sex differences in the electrocardiogram identified by three-dimensional torso-heart imaging reconstruction pipeline2025-12-08T15:30:11ZThe electrocardiogram (ECG) is used for diagnosis and risk stratification in myocardial infarction (MI). Women have a higher incidence of missed MI diagnosis and complications following infarction, and to address this we aim to provide quantitative information on sex-differences in ECG and torso-ventricular anatomical features and their interdependence. A novel computational automated pipeline is presented enabling the three-dimensional reconstruction of torso-ventricular anatomies for 425 post-MI subjects and 1051 healthy controls from UK Biobank clinical images. Regression models were created relating torso-ventricular and ECG parameters. We found that female hearts were positioned more posteriorly and superiorly than male, and in MI hearts were oriented more horizontally, especially for women. Post-MI women exhibited less QRS prolongation, requiring 27% more prolongation than men to exceed 120ms. Only half of the sex difference in QRS duration was associated with smaller female cavities. Lower STj amplitude in women was striking, associated with smaller ventricles, but also more superior and posterior cardiac position. Post-MI, T wave amplitude and R axis deviations were more strongly associated with posterior and horizontal cardiac positioning in women than in men. Our study highlights the need to quantify sex differences in anatomical features, their implications in ECG interpretation, and the application of clinical ECG thresholds in post-MI.2023-12-21T16:03:56ZRevision following reviewer commentsHannah J. SmithBlanca RodriguezYuling SangMarcel BeetzRobin P. ChoudhuryVicente GrauAbhirup Banerjeehttp://arxiv.org/abs/2512.07598v1Microfluidic gratings for X-ray Phase Contrast Imaging2025-12-08T14:46:40ZFabrication of X-ray gratings has surged in the last two decades thanks to their vast employment in X-ray Phase Contrast Imaging, an imaging technique able to boost X-ray sensitivity to detect otherwise invisible details. These high aspect ratio devices are usually fabricated by complex, costly, multi-step processes that limit their size and volume scaling. These steps commonly involve UV or X-ray lithography, semiconductor selective etching and high-Z metal plating, usually Au, which require expensive tools and materials. Here we present a proof-of-concept fabrication via soft lithography and Hg infusion of microfluidic X-ray absorption gratings and their performance in biomedical imaging. Such fabrication technique requires fewer, less expensive, and more scalable processes using alternative and more sustainable materials, while showing comparable visibility with their conventional Au-based, solid equivalent. Our results constitute a promising shift in X-ray optics fabrication that could significantly lower barriers to commercialization and accelerate the practical deployment of X-ray Phase Contrast Imaging.2025-12-08T14:46:40Z13 pages, 4 figuresAlessandro RossiFrancesco CoccimiglioAntonio FerraroTiziana RitaccoAlberto AstolfoMichele GiocondoVincenzo FormosoRaffaele Giuseppe AgostinoFrancesco IacovielloIoannis PapakonstantinouAlessandro Olivohttp://arxiv.org/abs/2512.07307v1Single-cell identification with quantum-enhanced nuclear magnetic resonance2025-12-08T08:48:53ZIdentification of individual cells within heterogeneous populations is essential for biomedical research and clinical diagnostics. Conventional labeling-based sorting methods, such as fluorescence-activated cell sorting and magnetic-activated cell sorting, enable precise sorting when reliable markers are available. However, their applicability is limited in cells lacking defined markers or sensitive to labeling, as labeling can compromise cellular viability and function. We present a single-cell identification approach using quantum-enhanced NMR with diamond nitrogen-vacancy centers for label-free detection of intracellular proton ($^1$H) signals. Using this method, we distinguish two human tumor cell lines by their proton spin-lattice ($T_1$) relaxation times, which serve as a cell-intrinsic physicochemical signature. It lays the groundwork for label-free sorting applications in rare cell analysis, personalized medicine, and single-cell diagnostics.2025-12-08T08:48:53Z23 pages, 4 figuresZhiyuan ZhaoQian ShiShaoyi XuXiangyu YeMengze ShenJia SuYa WangTianyu XieQingsong HuFazhan ShiJiangfeng Duhttp://arxiv.org/abs/2512.07148v1Quantitative Characterization of Brain Tissue Alterations in Brain Cancer Using Fractal, Multifractal, and IPR Metrics2025-12-08T04:15:32ZWe studied the structural alterations between healthy and diseased brain tissues using a multiparametric framework combining fractal analysis, fractal functional transformation, multifractal analysis, and the Inverse Participation Ratio (IPR) analysis. Accurate characterization of brain tissue microstructure is crucial for early detection and diagnosis of cancer. By applying box-counting methods on brightfield microscopy images, we estimated the fractal dimension (Df) and its logarithmic (ln(Df)) and functional (ln(Dtf)) forms to highlight spatial irregularities in the tissue architecture. While Df and ln(Df) exhibited long-tailed distributions distinguishing healthy from cancer tissues, ln(Dtf) provided significantly improved differentiation by emphasizing local structural variations. Additionally, multifractal analysis revealed broader f(α) vs α curves in cancerous samples, reflecting higher heterogeneity. IPR analysis based on light localization further demonstrated increased nanoscale variations in mass density, reflecting higher structural disorder in cancer tissues. Combining these complementary approaches creates a robust framework for measuring tissue complexity and holds great potential to improve microscopic diagnostic methods for brain cancer detection.2025-12-08T04:15:32Z18 pages, 8 figuresMousa AlrubayanSantanu MaityPrabhakar Pradhanhttp://arxiv.org/abs/2512.07061v1Alterations of brain tissue structural complexity and disorder in Alzheimer's disease (AD): Fractal, multifractal, fractal transformation, and disorder strength analyses2025-12-08T00:36:20ZAlzheimer's disease (AD) is characterized by progressive microstructural deterioration in brain tissue, yet conventional imaging and histopathology often lack the sensitivity needed to detect subtle early-stage changes. Here, we present a multiparametric framework combining fractal and multifractal analysis and their distributions to quantify structural alterations in human brain tissue affected by AD. Moreover, from the fractal and multifractal formalism, we introduced an innovative fractal functional distribution method, a novel technique that transforms fractal distribution into a Gaussian form. Statistically, these distribution parameters are easy to interpret and can distinguish between control and diseased tissues. Across samples, we identify pronounced threshold-dependent behavior of fractal and multifractal parameters, reflecting the intrinsic sparsity and heterogeneous intensity landscape of brain tissue. These threshold-sensitive signatures provide a framework for quantitative stage detection and may serve as biomarkers for early pathological transitions. In addition, we studied structural disorder and complexity using our established light localization technique, inverse participation ratio (IPR) analysis. IPR-based analysis demonstrates that increasing IPR pixel size highlights the elevation of structural alterations with disease progression. Together, these integrative analyses establish a robust, multi-scale quantitative framework for detecting microstructural alterations in AD, providing a promising foundation for early diagnosis and improved pathological assessment.2025-12-08T00:36:20Z22 pages, 8 figuresSantanu MaityMousa AlrubayanMohammad Moshahid KhanPrabhakar Pradhanhttp://arxiv.org/abs/2512.09945v1Fast generation of 3D flow obstacles from parametric surface models: application to cardiac valves2025-12-07T08:49:47ZDue to the computationally demanding nature of fluid-structure interaction simulations, heart valve simulation is a complex task. A simpler alternative is to model the valve as a resistive flow obstacle that can be updated dynamically without altering the mesh, but this approach can also become computationally expensive for large meshes.
In this work, we present a fast method for computing the resistive flow obstacle of a heart valve. The method is based on a parametric surface model of the valve, which is defined by a set of curves. The curves are adaptively sampled to create a polyline representation, which is then used to generate the surface. The surface is represented as a set of points, allowing for efficient distance calculations to determine whether mesh nodes belong to the valve surface. We introduce three algorithms for computing these distances: minimization, sampling, and triangulation. Additionally, we implement two mesh traversal strategies: exhaustive node iteration and recursive neighbor search. The latter significantly reduces the number of distance calculations by only considering neighboring nodes.
Our pipeline is demonstrated on both a previously reported aortic valve model and a newly proposed mitral valve model, highlighting its flexibility and efficiency for rapid valve shape updates in computational simulations.2025-12-07T08:49:47ZBob van der VuurstJiří KosinkaCristóbal Bertogliohttp://arxiv.org/abs/2512.06712v1Optimal experimental design with k-space data: application to inverse hemodynamics2025-12-07T08:01:50ZSubject-specific cardiovascular models rely on parameter estimation using measurements such as 4D Flow MRI data. However, acquiring high-resolution, high-fidelity functional flow data is costly and taxing for the patient. As a result, there is growing interest in using highly undersampled MRI data to reduce acquisition time and thus the cost, while maximizing the information gain from the data. Examples of such recent work include inverse problems to estimate boundary conditions of aortic blood flow from highly undersampled k-space data. The undersampled data is selected based on a predefined sampling mask which can significantly influences the performance and the quality of the solution of the inverse problem. While there are many established sampling patterns to collect undersampled data, it remains unclear how to select the best sampling pattern for a given set of inference parameters. In this paper we propose an Optimal Experimental Design (OED) framework for MRI measurements in k-space, aiming to find optimal masks for estimating specific parameters directly from k-space. As OED is typically applied to sensor placement problems in spatial locations, this is, to our knowledge, the first time the technique is used in this context. We demonstrate that the masks optimized by employing OED consistently outperform conventional sampling patterns in terms of parameter estimation accuracy and variance, facilitating a speed-up of 10x of the acquisition time while maintaining accuracy.2025-12-07T08:01:50ZMiriam LöckeAhmed AttiaDariusz UcínskiCristóbal Bertogliohttp://arxiv.org/abs/2511.03287v2Structural Stress as a Predictor of the Rate and Spatial Location of Aortic Growth in Uncomplicated Type B Aortic Dissection2025-12-06T22:21:42ZAccurate prediction of aortic expansion in uncomplicated type B aortic dissection (TBAD) can help identify patients who may benefit from timely thoracic endovascular aortic repair. This study investigates associations between biomechanical predictors derived from reduced-order fluid-structure interaction (FSI) analysis and aortic growth outcomes. Baseline and follow-up CT images from 30 patients with uncomplicated TBAD were obtained. For each patient, a reduced-order FSI analysis using the forward penalty stress computation method was performed on the baseline geometry. Aortic growth was quantified by registering baseline and follow-up surfaces using nonrigid registration. Mixed-effects linear and logistic regression analyses were performed to assess relationships between structural stress, wall shear stress (WSS), pressure and growth rate while accounting for inter-patient variability. Group comparison analyses were performed to evaluate spatial distributions of these biomechanical variables along the dissected aorta between patient groups categorized by optimal medical therapy (OMT) and aortic growth outcomes. Linear regression revealed a positive association between structural stress and aortic growth rate (p = 0.0003) and a negative association for WSS (p = 0.0227). Logistic regression yielded area under the receiver operator characteristic curve (AUCs) of 0.7414, 0.5953, 0.4991, and 0.6845 for structural stress, WSS, pressure, and aortic diameter, respectively. Group comparisons showed significant regional differences in structural stress, but not in diameter, WSS, or pressure, between groups defined by aortic growth and OMT outcomes. These results indicate that structural stress is a promising predictor of both the rate and location of aortic growth in uncomplicated TBAD, which supports its use in risk stratification models to identify patients at higher risk of TBAD progression.2025-11-05T08:41:44ZYuhang DuDepartment of Mechanical Engineering, Texas Tech University, Lubbock, TXYuxuan WuMercer University School of Medicine, Macon, GAHannah L. CebullDepartment of Radiology & Imaging Science, Emory University, Atlanta, GABangquan LiaoDepartment of Mechanical Engineering, Texas Tech University, Lubbock, TXRishika AgarwalThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GAAlan MerazDepartment of Mechanical Engineering, Texas Tech University, Lubbock, TXHai DongDivision of Cardiothoracic Surgery, Department of Surgery, Emory University School of Medicine, Atlanta, GAAsanish KalyanasundaramAortic Institute at Yale-New Haven Hospital, Yale University School of Medicine, New Haven, CTJohn N. OshinskiDepartment of Radiology & Imaging Science, Emory University, Atlanta, GAThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GARudolph L. GleasonThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GAThe George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GAJohn A. ElefteriadesAortic Institute at Yale-New Haven Hospital, Yale University School of Medicine, New Haven, CTBradley G. LeshnowerDivision of Cardiothoracic Surgery, Department of Surgery, Emory University School of Medicine, Atlanta, GAMinliang LiuDepartment of Mechanical Engineering, Texas Tech University, Lubbock, TXhttp://arxiv.org/abs/2512.06326v1Alterations of brain tissue structural complexity and disorder in Parkinson disease (PD): Fractal, multifractal, fractal transformation, and disorder strength analyses2025-12-06T07:01:53ZParkinson disease (PD) is marked by progressive neurodegeneration, yet early and subtle structural alterations in brain tissue remain difficult to detect with conventional imaging and analytical methods. Fractal and multifractal frameworks offer a principled way to quantify complex biological architecture, but their diagnostic utility in PD has been largely unexplored. In this study, we investigated the fractal and multifractal characteristics of human brain tissues to identify structural alterations associated with PD. Alongside conventional fractal and multifractal analysis, we employed a recently developed fractal functional distribution method that transforms distributions into a Gaussian form, thereby enhancing quantification. Using this combined approach, we found notable deviations across multiple distribution metrics in PD samples, offering potential for quantitative staging and diagnostic applications. The multifractal analysis revealed threshold-dependent variations in intensity-based measures, which are linked to the sparsity and heterogeneity of neural tissue and suggestive of potential biomarker value. Additionally, we applied inverse participation ratio (IPR) analysis to assess structural disorder, demonstrating that larger IPR pixel sizes correlate with increased structural complexity during disease progression. These complementary analyses outline a multi-layered quantitative profile of PD-related tissue disruption, offering a foundation for earlier, objective assessment of disease-associated microstructural change.2025-12-06T07:01:53Z22 pages, 8 figuresSantanu MaityMousa AlrubayanMohammad Moshahid KhanPrabhakar Pradhan