https://arxiv.org/api/j0MEOMw5QzR9XJB2p7oMx+zpAs02026-06-22T23:37:12Z898560015http://arxiv.org/abs/2512.16789v1Evaluation of a large-area double-sided silicon strip detector for quality assurance in ion-beam radiotherapy2025-12-18T17:24:53ZDesigned to provide quality assurance for ion-beam radiotherapy, the prototype fIVI (filtered Interaction Vertex Imaging) Range Monitoring System is a two-layer tracker which employs double-sided strip-segmented silicon detectors. To meet the high demands of a clinical environment, a large sensitive area is required, along with a fast and compact readout. As this device utilizes sensors and readout electronics adapted from particle physics, where the expected energy and count rate differ significantly from radiotherapy, validation was necessary to ensure that these sensors would function effectively at the order 100 MeV/u energies and order MHz count rates expected during clinical irradiation. Tests were conducted using scattered subclinical 19 MeV protons at high intensity, and clinical 207 MeV/u carbon ions at low intensity to independently validate these variables. The detection system is found to operate at rates up to 1.3 MHz, with a negligible fraction of events being affected by pileup. The efficiency of hit reconstruction is high, with a timestamp resolution of 6.25 ns, and a coincidence window of 31.25 ns, as is required for clinical event rates. With these settings, over 90% of particle interactions are able to reconstruct unique hit positions and contribute to track formation. This device is the first system using large-area, high-resolution detectors which meets the demanding count rate requirements associated with clinical radiotherapy.2025-12-18T17:24:53Z27 pages, 16 figuresDevin HymersInstitute for Nuclear Physics, University of Cologne, Cologne, GermanySebastian SchroederInstitute for Nuclear Physics, University of Cologne, Cologne, GermanyOlga BertiniGSI GmbH, Darmstadt, GermanyJohann HeuserGSI GmbH, Darmstadt, GermanyJoerg LehnertGSI GmbH, Darmstadt, GermanyChristian Joachim SchmidtGSI GmbH, Darmstadt, GermanyDennis MücherInstitute for Nuclear Physics, University of Cologne, Cologne, Germanyhttp://arxiv.org/abs/2512.16508v1Endorsing Titanium-Scandium Radionuclide Generator for PET and Positronium Imaging2025-12-18T13:20:19ZThe development of PET and positronium imaging techniques is strictly related to the availability of suitable radionuclides and robust radiochemistry platforms. Among the emerging candidates, $^{44}$Sc has attracted significant interest due to its favourable physical properties, including a half-life of $\sim$4 hours, a pure $β^{+}$ emission profile, and the additional prompt $γ$-emission that enables advanced triple-photon detection schemes. These characteristics make $^{44}$Sc particularly promising for highresolution imaging and novel quantitative methodologies. However, routine clinical and preclinical implementation requires a practical, sustainable, and cost-efficient production route. In this context, we propose a titanium-scandium radionuclide generator as an optimal solution. This study focuses on optimising the synthesis of the long-lived parent isotope, $^{44}$Ti ($T_{1/2}$ = 59.1 years), from which $^{44}$Sc can be selectively eluted in a chemically pure form when needed. An analysis of various production pathways was conducted, including proton and deuteron reactions on scandium, as well as $α$-particle and lithium-induced reactions on calcium, to determine the most efficient reaction parameters, target design, and expected yield. Furthermore, we identify some existing cyclotron facilities suitable for implementing this technology. Results indicate that efficient $^{44}$Ti production is achievable using proton beams in the 20-30 MeV range under extended irradiation conditions. The proposed generator system would enable routine and decentralised $^{44}$Sc supply. Its integration with the novel J-PET scanner may significantly reduce diagnostic costs and improve access to advanced PET imaging in regions with limited medical imaging infrastructure.2025-12-18T13:20:19ZPaweł MoskalAleksander KhreptakJarosław ChoińskiPete JonesIhor KadenkoAgnieszka Majkowska-PilipRudrajyoti PalitAnna StolarzRafał WalczakEwa Stępieńhttp://arxiv.org/abs/2512.16355v1Back with Weight: Revisiting Very Heavy Ions for Precision Radiotherapy2025-12-18T09:48:01ZAccelerated charged particles offer significant physical advantages over X-rays in radiotherapy. In addition to their superior depth-dose distribution, heavy ions provide notable biological benefits compared to protons. Specifically, at therapeutic energies, very heavy ions are expected to exhibit high relative biological effectiveness and a low oxygen enhancement ratio, making them potentially ideal for treating radioresistant tumors. Over fifty years ago, the Lawrence Berkeley Laboratory started a clinical trial to treat cancer patients with particles ranging from helium to argon. However, treatments with ions of atomic number greater than 10 proved highly toxic to normal tissue. Most patients were ultimately treated with helium ions, whose biological effects closely resemble those of protons. In recent years, novel strategies have emerged that can reduce normal tissue toxicity in radiotherapy while preserving tumor control. These advancements open the possibility of revisiting the clinical use of heavier ions. In this paper, we propose that neon ions may serve as an effective modality for treating resistant, hypoxic tumors. Their associated toxicity may be mitigated by employing approaches such as ultra-high dose rate (FLASH) or spatially fractionated radiotherapy. Current plans and prospects for the clinical application of neon ions will be discussed.2025-12-18T09:48:01ZIn press on Radiation ResearchJeannette JansenOlga SokolYolanda PrezadoMarco Durantehttp://arxiv.org/abs/2512.16266v1Pixel Super-Resolved Fluorescence Lifetime Imaging Using Deep Learning2025-12-18T07:28:10ZFluorescence lifetime imaging microscopy (FLIM) is a powerful quantitative technique that provides metabolic and molecular contrast, offering strong translational potential for label-free, real-time diagnostics. However, its clinical adoption remains limited by long pixel dwell times and low signal-to-noise ratio (SNR), which impose a stricter resolution-speed trade-off than conventional optical imaging approaches. Here, we introduce FLIM_PSR_k, a deep learning-based multi-channel pixel super-resolution (PSR) framework that reconstructs high-resolution FLIM images from data acquired with up to a 5-fold increased pixel size. The model is trained using the conditional generative adversarial network (cGAN) framework, which, compared to diffusion model-based alternatives, delivers a more robust PSR reconstruction with substantially shorter inference times, a crucial advantage for practical deployment. FLIM_PSR_k not only enables faster image acquisition but can also alleviate SNR limitations in autofluorescence-based FLIM. Blind testing on held-out patient-derived tumor tissue samples demonstrates that FLIM_PSR_k reliably achieves a super-resolution factor of k = 5, resulting in a 25-fold increase in the space-bandwidth product of the output images and revealing fine architectural features lost in lower-resolution inputs, with statistically significant improvements across various image quality metrics. By increasing FLIM's effective spatial resolution, FLIM_PSR_k advances lifetime imaging toward faster, higher-resolution, and hardware-flexible implementations compatible with low-numerical-aperture and miniaturized platforms, better positioning FLIM for translational applications.2025-12-18T07:28:10Z30 Pages, 9 FiguresPaloma Casteleiro CostaParnian Ghapandar KashaniXuhui LiuAlexander ChenAry PortesJulien BecLaura MarcuAydogan Ozcanhttp://arxiv.org/abs/2512.16140v1ResDynUNet++: A nested U-Net with residual dynamic convolution blocks for dual-spectral CT2025-12-18T03:52:18ZWe propose a hybrid reconstruction framework for dual-spectral CT (DSCT) that integrates iterative methods with deep learning models. The reconstruction process consists of two complementary components: a knowledge-driven module and a data-driven module. In the knowledge-driven phase, we employ the oblique projection modification technique (OPMT) to reconstruct an intermediate solution of the basis material images from the projection data. We select OPMT for this role because of its fast convergence, which allows it to rapidly generate an intermediate solution that successfully achieves basis material decomposition. Subsequently, in the data-driven phase, we introduce a novel neural network, ResDynUNet++, to refine this intermediate solution. The ResDynUNet++ is built upon a UNet++ backbone by replacing standard convolutions with residual dynamic convolution blocks, which combine the adaptive, input-specific feature extraction of dynamic convolution with the stable training of residual connections. This architecture is designed to address challenges like channel imbalance and near-interface large artifacts in DSCT, producing clean and accurate final solutions. Extensive experiments on both synthetic phantoms and real clinical datasets validate the efficacy and superior performance of the proposed method.2025-12-18T03:52:18ZZe YuanWenbin LiShusen Zhaohttp://arxiv.org/abs/2508.17201v2Root Cause Analysis of Radiation Oncology Incidents Using Large Language Models2025-12-18T03:14:13ZPurpose To evaluate the reasoning capabilities of large language models (LLMs) in performing root cause analysis (RCA) of radiation oncology incidents using narrative reports from the Radiation Oncology Incident Learning System (RO-ILS), and to assess their potential utility in supporting patient safety efforts.
Methods and Materials Four LLMs, Gemini 2.5 Pro, GPT-4o, o3, and Grok 3, were prompted with the 'Background and Incident Overview' sections of 19 public RO-ILS cases. Using a standardized prompt based on AAPM RCA guidelines, each model was instructed to identify root causes, lessons learned, and suggested actions. Outputs were assessed using semantic similarity metrics (cosine similarity via Sentence Transformers), semi-subjective evaluations (precision, recall, F1-score, accuracy, hallucination rate, and four performance criteria: relevance, comprehensiveness, justification, and solution quality), and subjective expert ratings (reasoning quality and overall performance) from five board-certified medical physicists.
Results LLMs showed promising performance. GPT-4o had the highest cosine similarity (0.831), while Gemini 2.5 Pro had the highest recall (0.799) and accuracy (0.918). Hallucination rates ranged from 11% to 61%. Gemini 2.5 Pro outperformed others across performance criteria and received the highest expert rating (4.8/5). Statistically significant differences in accuracy, hallucination, and subjective scores were observed (p < 0.05).
Conclusion LLMs show emerging promise as tools for RCA in radiation oncology. They can generate relevant, accurate analyses aligned with expert judgment and may support incident analysis and quality improvement efforts to enhance patient safety in clinical practice.2025-08-24T03:33:26ZYuntao WangMariluz De OrnelasMatthew T. StudenskiElizabeth BossartSiamak P. Najad-DavaraniYunze Yanghttp://arxiv.org/abs/2512.15465v1Female anatomies disguise ECG abnormalities following myocardial infarction: an AI-enabled modelling and simulation study2025-12-17T14:10:15ZThe electrocardiogram (ECG) is modulated by torso-heart anatomy, and this challenges patients' diagnosis and risk stratification. This study aims to quantify how torso-heart anatomical factors affect sex-differences in ECG biomarkers in acute and chronic myocardial infarction (MI). We exploit the perfect control of AI-augmented multiscale modelling and simulation, based on clinical magnetic resonance imaging (MRI) data and ECGs for model construction and validation. A cohort of 1720 torso-ventricular anatomies (50% female) was constructed from MRIs of healthy and post-MI participants in the UK Biobank study. 8600 ECG simulations were performed considering anatomical variability and 3 electrophysiological stages (healthy, acutely ischemic, and infarcted). The effect of cardiac size, position, and orientation on each ECG biomarker was quantified. Female anatomies had larger distances between the infarct and ECG electrodes (relative to cardiac size), and larger angles between the infarct normal and ECG lead axes, both primarily caused by their more superior cardiac position. This reduced ST-elevation and caused low-amplitude late depolarisation and repolarisation tails to be missed, shortening QRS duration (QRSd) and T-peak-to-end interval (TpTe). The position and orientation of the heart impacted TpTe more severely than QRSd. AI-enabled mechanistic modelling and simulation identify smaller ventricles, superior cardiac position, and different ventricular orientation as key anatomical contributors of shorter QRS and T waves, and lower ST-elevation, in female versus male anatomies. This provides a blueprint for quantifying the impact of anatomical sex differences on functional markers and enables future work in tailoring clinical guidelines considering unique patient anatomy to reduce biased outcomes.2025-12-17T14:10:15ZHannah SmithAbhirup BanerjeeLeto Luana RiebelRuben DosteMaxx HolmesVicente GrauBlanca Rodriguezhttp://arxiv.org/abs/2512.15059v1Cross-Axis Weighted Harmonic Method: A Frequency-Domain Approach for Enhanced Resolution in Magnetic Particle Imaging2025-12-17T03:52:29ZMagnetic Particle Imaging (MPI) is a promising imaging modality that tracks magnetic nanoparticles (MNPs) to generate real time, high-resolution images. However, achieving an optimal balance between strong signal strength and sharp image clarity remains challenging. Higher drive field frequencies improve the signal-to-noise ratio (SNR), but also risk image blurring due to nanoparticle relaxation effects. To address this, we developed an end-to-end MPI simulation framework that models MNPs behavior, magnetic field dynamics, signal acquisition, and image reconstruction across a wide frequency range (20 to 85 kHz). Central to this framework is Cross-Axis Harmonic Analysis (CAHA), a novel, frequency-domain signal processing technique that adaptively extracts high-SNR harmonics from the x, y, and z directions for improved signal reconstruction.
Using a simulated 3D vascular phantom, CAHA significantly enhanced image quality, achieving sub-millimeter resolution (0.8 mm FWHM at 85 kHz), strong noise suppression (nRMSE as low as 0.01), and structural fidelity (SSIM up to 0.94 at 55 kHz). The peak SNR reached 29.7 dB at 85 kHz. The signal processed with CAHA was also tested with other reconstruction methods; when combined with total variation regularization, CAHA achieved a pSNR of 37.91 dB. Evaluation on the Open MPI dataset further demonstrated up to 20% resolution improvement, confirming CAHA's robustness on real-world data.
Although minor blurring was observed at the highest frequency due to relaxation, CAHA consistently maintained image clarity. By leveraging directional harmonic content rather than the full signal, CAHA sets a new benchmark for sharper, faster, and more robust MPI imaging.2025-12-17T03:52:29ZBiomedical Signal Processing and Control 115 (2026) 109402Abuobaida M. khairWenjing JiangMoritz WildgruberWenjun XiXiaopeng Ma10.1016/j.bspc.2025.109402http://arxiv.org/abs/2412.09351v3Dynamic optical coherence tomography algorithm for label-free assessment of swiftness and occupancy of intratissue moving scatterers2025-12-17T03:37:53ZDynamic optical coherence tomography (DOCT) statistically analyzes fluctuations in time-sequential OCT signals, enabling label-free and three-dimensional visualization of intratissue and intracellular activities. Current DOCT methods, such as logarithmic intensity variance (LIV) and OCT correlation decay speed (OCDS) have several limitations.Namely, the DOCT values and intratissue motions are not directly related, and hence DOCT values are not interpretable in the context of the tissue motility. We introduce a new DOCT algorithm that provides more direct interpretation of DOCT in the contexts of dynamic scatterer ratio and scatterer speed in the tissue.The detailed properties of the new and conventional DOCT methods are investigated by numerical simulations, and the experimental validation with in vitro and ex vivo samples demonstrates the feasibility of the new method.2024-12-12T15:18:30ZBiomed. Opt. Express 17, 322-345 (2026)Rion MorishitaPradipta MukherjeeIbrahim Abd El-SadekTanatchaya SeesanTomoko MoriAtsuko FurukawaShinichi FukudaDonny LukmantoSatoshi MatsusakaShuichi MakitaYoshiaki Yasuno10.1364/BOE.574972http://arxiv.org/abs/2512.14933v1Vector Flow Imaging in Layered Models With a High Speed of Sound Contrast Using Pulse-Echo Ultrasound and Photoacoustics2025-12-16T21:55:30ZIn this study, we develop vector flow imaging techniques for multi-layered models with a high wavespeed contrast using photoacoustic and ultrasonic imaging. We use refraction-corrected delay-and-sum image reconstruction (RC-DAS), which enforces Snell's law to accurately calculate time delays within each layer. We compare RC-DAS against conventional delay-and-sum for vector flow imaging in benchtop phantoms made of transparent polymethyl methacrylate (PMMA) in a water bath. We study the flow beneath a PMMA layer using two phantoms, where the PMMA layer has different shapes and thicknesses. We image a slow-moving suspension of carbon microspheres (~4 mm/s) using interleaved photoacoustic and multi-angle plane wave ultrasound acquisitions measured with a 7.6 MHz linear ultrasound array. Photoacoustic waves are generated by a 1064 nm wavelength nanosecond-pulsed laser at 50 Hz, and multi-angle plane wave ultrasound data are acquired at 100 Hz for eleven steering angles between $\pm$10$^\circ$. RC-DAS improves the flow speed accuracy, reducing the mean absolute error by 0.41-0.63 mm/s compared to the expected flow profile. The error in direction estimates improves when we use RC-DAS, with the interdecile range reducing by up to 17$^\circ$. This work emphasises the importance of refraction correction for accurate flow measurements in layered media with photoacoustics and ultrasonic imaging. While both imaging modalities can quantify flow in these multi-layered models, the modality best suited for a specific application will depend on the imaging target and flow dynamics. These techniques show promise for biomedical applications such as intraosseous and transcranial blood flow quantification, and in nondestructive testing to monitor fluid motion.2025-12-16T21:55:30Z14 pages, 11 figures. PreprintCaitlin SmithGuillaume RenaudKasper van WijkJami Shepherdhttp://arxiv.org/abs/2512.14210v1The Thermal Unbalance Effect Induced by a Journal Bearing in Rigid and Flexible Rotors: Experimental Analysis2025-12-16T09:09:11ZThe present work presents the experimental analyses of a rigid (short) and a flexible (long) rotor subject to thermal unbalance effects. The rotors are supported by a ball bearing and by a cylindrical journal bearing. The differential heating generated in the journal bearing is responsible for the thermal unbalance. The results obtained with the short rotor at 7 krpm showed an increase in the synchronous amplitudes but slight phase changes before stabilization. The pronounced hysteresis of the synchronous amplitudes obtained during coast-down proved that the amplitude increase is due to the thermal unbalance. The results obtained for the long rotor at 6.6 krpm showed the same stabilized response when start-up was performed in 180___s. However, an instability leading to journal bearing contact was triggered when the start-up time was decreased to 80___s. The presented experimental results are the synchronous amplitudes and phases, the mean temperatures, and the maximum temperature differences of the journal and of the bearing and the phase lags between the high spot and the hot spot.2025-12-16T09:09:11ZTribology Transactions, 2019, pp.1-16Thibaud PlantegenetTriboLubMihai ArghirTriboLubMohamed-Amine HassiniTriboLubPascal JollyTriboLub10.1080/10402004.2019.1658836http://arxiv.org/abs/2512.13966v1Super-Resolution Posterior Ocular Microvascular Imaging Using 3-D Ultrasound Localization Microscopy With a 32X32 Matrix Array2025-12-16T00:10:20ZThe purpose of this study is to enable in-vivo three-dimensional (3-D) ultrasound localization microscopy (ULM) of posterior ocular microvasculature using a 256-channel system and a 1024-element matrix array, and to overcome limitations of restricted transmit angles, sound speed mismatch caused by the crystalline lens and surrounding tissues, and the low signal-to-noise ratio (SNR) of microbubble signals. To address phase distortions from the crystalline lens, which has a higher speed of sound (SOS) than surrounding tissues, a region-dependent SOS beamforming approach was implemented to improve microbubble resolution. A 4-D non-local means filter was subsequently applied to suppress background noise and enhance microbubble contrast. The proposed method improved localization accuracy and image quality, achieving a spatial resolution of 63 um, while Fourier shell correlation (1/2-bit threshold) confirmed a global resolution of approximately 59 um. Higher mean normalized cross-correlation coefficients between the microbubbles and the system point-spread function, obtained with the proposed method (approximately 0.67), compared with those without the proposed method (approximately 0.60), indicate enhanced microbubble signal quality. Furthermore, the 3-D bi-directional vessel density and flow-velocity maps were reconstructed, capturing detailed choroidal vascular and hemodynamic patterns. These results demonstrate that region-dependent SOS beamforming combined with spatiotemporal denoising enables high-resolution posterior ocular ULM and provides a practical pathway toward quantitative 3-D assessment of retinal and choroidal microvasculature for potential clinical use.2025-12-16T00:10:20ZJunhang ZhangU-Wai LokJingke ZhangChengwu HuangXin SunChi-Feng ChangBaoqiang LiuChen GongYushun ZengKaipeng JiRyan M. DeRuiterJingyi YinLijie HuangYanzhe ZhaoYing LiuBrian SongMark HumanyunShigao ChenQifa Zhouhttp://arxiv.org/abs/2512.13527v1DarkSPARC: Dark-Blood Spectral Self-Calibrated Reconstruction of 3D Left Atrial LGE MRI for Post-Ablation Scar Imaging2025-12-15T16:56:58ZPurpose: To develop DarkSPARC, a retrospective, training-free, self-calibrated spectral reconstruction method that converts routine bright-blood 3D left atrial (LA) late gadolinium enhancement (LGE) MRI into a dark-blood image, and to quantify its impact on LA scar-pool CNR, SNR, effective CNR (eCNR), and scar quantification accuracy.
Methods: DarkSPARC embeds bright-blood LA LGE into a calibrator-conditioned (N+1)-dimensional spectral domain and reconstructs a dark-blood-like image using scan-specific spectral landmarks. A scan-specific 3D numerical phantom framework was built from LAScarQS post-ablation LGE by cloning remote myocardium into the LA wall and imposing controlled scar burden. Five baseline cases spanning the 5th-95th percentiles of native scar-pool CNR, each with multiple scar burdens and 10 CNR degradation levels, yielded 200 phantoms. For every phantom, LA scar-pool CNR, SNR, eCNR, and Scar% were measured on bright-blood and DarkSPARC images. In vivo performance was evaluated in 60 public post-ablation scans of atrial fibrillation patients.
Results: In scan-specific phantoms, DarkSPARC increased LA scar-pool CNR, SNR, and eCNR over bright-blood in all 200 experiments, with DarkSPARC/bright-blood ratios up to about 30-fold for CNR and about 6-fold for SNR in the lowest-CNR conditions. At 70% CNR degradation, bright-blood underestimated ground-truth LA Scar% by -37% to -54%, whereas DarkSPARC reduced bias to about -3% to -5%. In vivo, DarkSPARC similarly improved metrics: median scar-pool CNR, SNR, and eCNR increased from 20.0 to 135.9 (6.8x), 70.6 to 200.6 (2.8x), and 0.22 to 0.75 (3.4x), respectively (all p<0.001), and LA Scar% increased from 3.9% to 9.75%.
Conclusion: DarkSPARC is a self-calibrated, training-free reconstruction that yields dark-blood 3D LA LGE, boosting CNR/SNR/eCNR and stabilizing reliable scar quantification without extra scans.2025-12-15T16:56:58ZMohammed S. M. Elbazhttp://arxiv.org/abs/2512.13432v1Fast label-free point-scanning super-resolution imaging for endoscopy2025-12-15T15:20:14ZOptical endoscopy plays a crucial role in minimally invasive medical diagnostics and therapeutic procedures. Nonetheless, state-of-the-art endoscopic zoom objectives are bulky, requiring multi-element lens actuation, which can limit continued miniaturization. Point-scanning super-resolution approaches improve spatial resolution by illuminating the scene with a reduced-width focused spot, yet mechanical scanning requirements limit applicability in clinical settings. Here, we experimentally demonstrate a Fast label-free point-scanning super-resolution (Flaps) microscopy system, which exploits a multi-level phase-only diffractive optical element (DOE) to generate super-resolution spot(s) and uses a high-speed digital micromirror device (DMD) to deliver the illumination without mechanical scanning. Two imaging architectures are explored: a single super-resolution spot (0.47 Airy spot) or a 5 times 5 super-resolution spot array (0.52 Airy spot) in the far-field; the DMD scans the spot or spot array in the object plane at kHz rates. To demonstrate super-resolution imaging with high-speed acquisition using optical elements suitable for future deployment in endoscopy, we image a label-free resolution test target and fluorescently labelled cells.2025-12-15T15:20:14Z20 pages,7 figuresNing XuCalum WilliamsGraham SpicerQixia WangQiaofeng TanSarah E. Bohndiekhttp://arxiv.org/abs/2407.21600v3Robust Simultaneous Multislice MRI Reconstruction Using Slice-Wise Learned Generative Diffusion Priors2025-12-15T01:42:28ZSimultaneous multislice (SMS) imaging is a powerful technique for accelerating magnetic resonance imaging (MRI) acquisitions. However, SMS reconstruction remains challenging due to complex signal interactions between and within the excited slices. In this study, we introduce ROGER, a robust SMS MRI reconstruction method based on deep generative priors. Utilizing denoising diffusion probabilistic models (DDPM), ROGER begins with Gaussian noise and gradually recovers individual slices through reverse diffusion iterations while enforcing data consistency from measured k-space data within the readout concatenation framework. The posterior sampling procedure is designed such that the DDPM training can be performed on single-slice images without requiring modifications for SMS tasks. Additionally, our method incorporates a low-frequency enhancement (LFE) module to address the practical issue that SMS-accelerated fast spin echo (FSE) and echo planar imaging (EPI) sequences cannot easily embed fully-sampled autocalibration signals. Extensive experiments on both retrospectively and prospectively accelerated datasets demonstrate that ROGER consistently outperforms existing methods, enhancing both anatomical and functional imaging with strong out-of-distribution generalization. The source code and sample data for ROGER are available at https://github.com/Solor-pikachu/ROGER.2024-07-31T13:34:14ZPublished in Medical Image Analysis, Volume 108, 2026, 103851Shoujin HuangGuanxiong LuoYunlin ZhaoYilong LiuYuwan WangKexin YangJingzhe LiuHua GuoMin WangLingyan ZhangMengye Lyu10.1016/j.media.2025.103851