https://arxiv.org/api/QxSz1BUjmYWW1zzwddfGzgGDBwU 2026-09-10T21:20:54Z 9200 60 15 http://arxiv.org/abs/2608.22487v1 Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review 2026-08-23T16:15:40Z Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging. 2026-08-23T16:15:40Z Can Deniz Bezek Orcun Goksel http://arxiv.org/abs/2608.22351v1 Shimmer: End-to-End Open-Source Passive B0 Shimming Methodology for Low-Field MRI Magnets 2026-08-23T10:38:47Z Low-field MRI scanners based on permanent magnet arrays require accurate B0 shimming to achieve sufficient field homogeneity for imaging. Here, we present Shimmer, an open-source methodology for passive shimming of low-field MRI magnets using additional NdFeB magnets placed outside the main magnet array. The end-to-end methodology combines magnetic field mapping, magnetic field simulations, numerical optimization of shim magnet positions and orientations, and automated generation of 3D-printable shim holders. Continuous magnet rotations and several optimization strategies are considered and evaluated. The method was validated and applied to three different permanent magnet arrays ~50 mT in 200 mm diameter spherical volumes, reducing initial field inhomogeneities of 9361ppm, 31721 ppm and 34143 ppm to 888 ppm, 1812 ppm and 1602 ppm respectively. The improved homogeneity enabled undistorted MR imaging of a phantom. Shimmer provides a reproducible and adaptable approach for improving the performance of low-field MRI magnets. 2026-08-23T10:38:47Z 22 pages, 12 Figures + supplementary information Ilia Kulikov David Schote Helge Herthum Martin Häuer Kimon Hadjikiriakos Jan Gregor Frintz Sonja Buxbaum-Conradi Manuel Moritz Tobias Redlich Lukas Winter http://arxiv.org/abs/2211.00316v12 Hessian-free Ray-Born Inversion for Quantitative Ultrasound Tomography of Weakly Heterogeneous Media 2026-08-23T07:04:21Z This study presents a frequency-domain, Hessian-free ray-Born inversion method for quantitative ultrasound tomography, extending the author's previous Hessian-based approach. Both approaches model acoustic wave propagation using a ray-based approximation of the Green's function in weakly heterogeneous media, and perform the inversion iteratively in the frequency domain, progressing from low to high frequencies. In the earlier method, each frequency subproblem was solved through iterative inversion of the Hessian operator, a process that not only increased computational cost but also made the update steps more sensitive to noise. The present work addresses these limitations by transforming a full-frequency Hessian operator into an identity operator through a specific preconditioning scheme, thereby enabling a single-step inversion for each frequency subproblem. This reformulation reduces the computational expense by approximately an order of magnitude relative to the Hessian-based approach, while yielding robust reconstructions with reduced sensitivity to noise by eliminating the ill-conditioning of the Hessian operator. Furthermore, compared with the author's previous study, the present work improves the approximation of the geometrical component of the wave amplitude by introducing a paraxial ray-tracing framework, thereby further enhancing both computational efficiency and reconstruction accuracy. The inversion approach proposed in the present study has enabled the first successful translation of acoustic inverse scattering methods relying on first-scattered waves to a clinical setting. 2022-11-01T07:49:11Z This is the final version of the article Ashkan Javaherian http://arxiv.org/abs/2608.21903v1 A novel strategy for achieving a low-field lightweight permanent MRI magnet system with good magnetic field homogeneity and low eddy current 2026-08-22T10:30:10Z In low-field, lightweight, pole-pieceless permanent-magnet MRI systems built with sintered Nd-Fe-B or Sm-Co magnets, the rapid switching of gradient fields readily induces eddy currents in the sintered magnets, leading to image artifacts. To address this, we report for the first time a Sm-Fe-N permanent-magnet MRI system based on anisotropic Sm-Fe-N bonded magnets, whose high electrical resistivity reduces the eddy currents in the X, Y and Z directions to 0.093%, 0.172% and 2.38%, respectively, while a magnetic field inhomogeneity below 150 ppm is achieved at the boundary of a 220 mm diameter of spherical volume (DSV). Compared with sintered Nd-Fe-B and Sm-Co magnets, using Sm-Fe-N bonded magnets as the source of the static magnetic field not only suppresses eddy currents but also makes a closely tiled, densely packed magnetic-circuit layout feasible, providing a more uniform static magnetic field for the MRI system. Imaging results free of obvious geometric distortion and banding artifacts further indicate that the Sm-Fe-N magnet system delivers low eddy currents and high static magnetic field homogeneity. 2026-08-22T10:30:10Z 7 figures; supplementary material included Jingzhi Han Jiangqian Guo Peng Shen Xiao Tong Wenyun Yang Ziheng Zhang Jie Liu Tianzhuo Yang Yikun Fang Shunquan Liu Jie Zhang Qing Xu Jinbo Yang http://arxiv.org/abs/2608.21861v1 A scattering correction method for CT reconstruction based on the Wavelet Adaptive Material-dependent Boltzmann Transport Equation (WAM-BTE) 2026-08-22T09:12:47Z X-ray computed tomography (CT) is an essential imaging technology in clinical diagnosis. However, scattered photons can reduce image contrast and introduce CT value bias, which severely degrades image quality. Recently, scatter correction methods based on the Boltzmann transport equation (BTE) have attracted increasing attention due to their high physical accuracy and flexibility. Nevertheless, existing BTE-based methods usually employ single-material models, which cannot accurately describe the nonlinear energy dependence of photon interaction cross-sections in different materials. In this work, a scatter correction method based on the wavelet adaptive material-dependent BTE (WAM-BTE) is proposed. The conventional single-material model is extended to a multi-material model by introducing material-dependent scattering distributions. Furthermore, an adaptive multi-scale framework is established through wavelet decomposition. The low-frequency wavelet coefficients are used for coarse-scale scatter estimation to reduce computational complexity, while the high-frequency wavelet energy of high attenuation materials is utilized for adaptive local refinement. Theoretical analysis demonstrates that, when using the Haar basis function, the low-frequency wavelet coefficients at the $w$-th level are mathematically equivalent to block-average downsampling with a scale factor of $2^w$, except for a deterministic normalization factor. Experimental results show that the proposed WAM-BTE method achieves comparable accuracy to the Monte Carlo method while preserving the computational efficiency of coarse-scale estimation. The scatter calculation time for a single projection view is reduced to the millisecond level. 2026-08-22T09:12:47Z Huiying Pan Xu Jiang Xing Zhao http://arxiv.org/abs/2608.21481v1 Multimodal pseudo-CT synthesis for PET attenuation correction using separate modality encoding and topogram conditioning 2026-08-21T09:29:29Z We participated in the BIC-MAC Challenge with a multimodal 3D patch-based U-Net for pseudo-CT generation from NAC-PET, MRI, and 2D topograms. By using separate PET and MR encoders, multi-scale feature fusion, and FiLM-based topogram conditioning at the bottleneck, we obtain a model that integrates complementary cross-modal information while reducing reliance on precise voxel-wise correspondence between modalities. Our final submission can be found: https://github.com/rrr-uom-projects/BIC-MAC-MICCAI2026 2026-08-21T09:29:29Z Technical report for the BIC-MAC 2026 Challenge Rory Bell Artemis Bouzaki Jiaming Cao Jasmine Morrison Chelsea Sargeant http://arxiv.org/abs/2608.20561v1 Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising 2026-08-20T20:49:25Z Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED. 2026-08-20T20:49:25Z Merve Gülle Junno Yun Yaşar Utku Alçalar Mehmet Akçakaya http://arxiv.org/abs/2608.20519v1 An integrated diffusion-weighted imaging processing and interpretation platform for MR-guided radiotherapy 2026-08-20T19:33:08Z Background: Magnetic resonance imaging-guided linear accelerators (MR-Linacs) allow diffusion-weighted imaging (DWI) to be acquired at every treatment fraction, but converting these low-signal-to-noise-ratio acquisitions into clinical decisions requires both reliable quantitative processing and an interpretation that reconciles a scattered and often contradictory literature. Purpose: To describe and evaluate an integrated, web-based platform that carries raw MR-Linac DWI to a structured, literature-grounded clinical interpretation, and to assess its retrieval-augmented generation (RAG) interpretation module by independent expert rating. Methods: The platform couples a deep-learning processing pipeline, comprising distortion correction, denoising, and intravoxel incoherent motion (IVIM)/apparent diffusion coefficient (ADC) fitting, with longitudinal region-of-interest analysis and a RAG interpretation agent. The agent reasons over a two-layer knowledge base of curated publications (a structured catalog index plus line-indexed full text), delegates arithmetic to deterministic tools, and is designed to trace each statement to a source document, section, and line range. One medical physicist and one physician independently rated the agent's reports for nine longitudinal glioblastoma cases on a 1-5 scale across three metrics: clinical-reasoning soundness, literature-citation quality, and overall clinical utility. Results: Across 54 ratings, the pooled mean was 4.65 +/- 0.80, with 93% of ratings >= 4; metric means were 4.6 (reasoning), 4.5 (citation), and 4.8 (utility), and raters agreed within one point on 85% of paired ratings. Conclusions: A single platform can integrate MR-Linac DWI post-processing with traceable, expert-evaluated clinical interpretation, while highlighting the safeguards needed to verify LLM-generated reasoning in radiation oncology. 2026-08-20T19:33:08Z 29 pages Yunxiang Li Yan Dai Yen-Peng Liao Jie Deng Jill B De Vis You Zhang http://arxiv.org/abs/2608.20112v1 Flow Matching-Based PET Image Reconstruction 2026-08-20T14:42:44Z Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction. 2026-08-20T14:42:44Z 10 pages, 8 figures Fumio Hashimoto Ziqian Huang Tatsuya Yokota Kuang Gong http://arxiv.org/abs/2608.19062v2 A Reference System for Open Source Portable Low-Field MRI 2026-08-20T14:10:42Z Despite its renewed attention, the pathway to point-of-care portable low-field MRI systems remains challenging, limiting adoption across research groups. Incomplete documentation limits reproducibility, causing redesign and complicating cross-system comparison. Moreover, non-standardized testing and characterization complicates ethical approval for clinical studies. We present an open-source reference system for portable low-field MRI designed to support replication, reproducibility, benchmarking, and quantitative comparison. The system is fully open source, based on a ~50 mT permanent magnet, and integrated with a cloud-native acquisition platform. Pulseq-based calibration, characterization, and imaging sequences assessed noise level, eddy currents, image-based SNR, and geometric accuracy. Quantitative T1, T2, and B0 mapping sequences were developed and evaluated against reference values. Initial results from independent replications at two sites were compared. The system reached a noise level of 1.4 relative to the thermal noise floor and short eddy-current decay constants of 27-32 us across all gradient channels. Geometric deviations were below 2 mm over the field of view. Image-based SNR were consistent between the independent replications. Measured T1 values closely matched specified values, with an average absolute error of 3.1(1.8)%, while T2 values were overestimated by 10.4(5.8)%. Simulations showed only marginal errors for both quantities, suggesting experimental error sources for T2 mapping. The reference system combines openly documented hardware, software, calibration procedures, phantoms, quantitative MRI, and simulation tools in a reproducible ecosystem, aiming to support cross-site comparability, reproducible research, and collaborative development of future portable low-field MRI technologies. 2026-08-19T16:02:59Z 23 pages, 11 figures David Schote Helge Herthum Umberto Zanovello Julia Pfitzer Ivo Jutte Jan Gregor Frintz Ilia Kulikov Sebastian Littin Frank Seifert Christoph Kolbitsch Lukas Winter http://arxiv.org/abs/2608.19823v1 Simultaneous 3D co-registered perfusion and oxygenation with ULM, photoacoustic imaging, and a planar matrix array 2026-08-20T09:21:13Z Objective. Joint assessment of tissue oxygenation and microvascular perfusion could offer valuable insights into vascular function across a wide range of biomedical applications. Multispectral photoacoustic imaging enables the evaluation of blood oxygenation, while ultrasound localization microscopy provides sub-diffraction visualization of the microvasculature and blood perfusion. Here, we combine these two complementary modalities to simultaneously generate co-registered, volumetric maps of blood oxygenation and perfusion. Approach. Photoacoustic imaging and ultrasound localization microscopy are both ultrasound-based techniques. We developed an imaging platform that integrates the two modalities using a single planar ultrasonic matrix array, a state-of-the-art array for 3D ultrasound localization microscopy. The bimodal platform was validated in vitro using vessel-mimicking phantoms, then in vivo in mice. Main results. In vitro bimodal images of tubes injected with contrast agents demonstrated a coregistration accuracy of 20 $μ$m and revealed complementary structural and functional information. Multispectral photoacoustic imaging achieved oxygen saturation measurements spanning the physiological range (60-95 %) with 5 % accuracy using only five optical wavelengths. In vivo imaging of healthy mouse tissues with known vascular anatomy further demonstrated the ability of the proposed platform to jointly characterize blood oxygenation and microvascular perfusion. Significance. This work experimentally validates a bimodal photoacoustic imaging-ultrasound localization microscopy approach using a planar ultrasound array. We characterized the functional imaging performance of this platform and identified limited-view artifacts inherent to this array configuration in photoacoustic imaging. These findings establish a foundation for adopting the platform in future studies of murine models and for advancing this promising bimodal approach. 2026-08-20T09:21:13Z Léa Davenet LIB, CRC Jacques Battaglia LIB Franck Lager LIB Pascal Dargent LIB Charlotte Lussey-Lepoutre CRC Bertrand Tavitian PARCC Olivier Couture LIB Lori Bridal LIB Jérôme Gateau LIB http://arxiv.org/abs/2607.02710v3 Electric Field Propagation with Spinal Cord Stimulation 2026-08-19T15:18:51Z Spinal cord stimulation is routinely used for the treatment of chronic pain, and is increasingly being investigated for the restoration of movement after paralysis. However, most of our current knowledge on epidural spinal cord stimulation relies on empirical approaches and semi-hybrid models. Hence, optimizing this therapy requires a better theoretical understanding of how stimulation affects the target neural structures. Using the physical properties of tissues combined with an electromagnetic, dielectric, and metallic description of them, we derived the electric field transmission coefficient through a given number of layers of tissue in the spinal cord. We then used this model to calculate the transmission of electric field energy in target neural tissues such as grey or white matter for different pulse width. Simulations suggest that the propagation through the tissues of the spinal cord of an epidurally applied electric field has a complex relationship with the field pulse width. In addition the electric field energy is absorbed at the junction between dura matter and cerebrospinal fluid, and within the cerebrospinal fluid as induced current. These currents hit the different bodies floating within the cerebrospinal fluid, and/or dorsal horn in a very localized region of the spinal cord. The proposed models allow theoretical calculation of the transmission factor for different numbers of layers of tissue within the spinal canal, and for different electric field pulse widths. This eases the prediction of the expected energy reaching each layer of the spinal cord for different tissues, parameters, and electrode configurations, simplifying the optimization of spinal cord stimulation treatment. 2026-07-02T18:54:46Z Pre print 27 pages, 6 figures with a 9 pages of supplementary material Olivier Bernard Réjean Fontaine Oussama Eddaoui Jonathan Harnie Alain Frigon Christian Iorio-Morin http://arxiv.org/abs/2608.18055v2 Primitive Representation Learning for Unsupervised Dynamic Contrast Enhanced MRI Reconstruction 2026-08-19T13:26:05Z Reliable quantitative analysis of dynamic contrast-enhanced MRI requires high-quality spatiotemporal reconstructions at high undersampling rates. Scan-specific reconstructions using Gaussian and Gabor primitives have shown promising results without the need for large training datasets, but have not addressed the additional dimension of dynamic contrast. We propose a multi-dimensional, primitive based framework for dynamic contrast-enhanced MRI reconstruction that disentangles the underlying anatomy, the dynamic contrast enhancement, and residual motion into separate temporal basis functions, thereby enabling a geometrical interpretation of the representation. We show that this architecture achieves performance competitive with conventional reconstruction methods, both in reconstruction quality and in the accuracy of extracted aorta and kidney enhancement curves. The modular tier design extends naturally to additional dynamic factors and higher acceleration rates. Code available at https://github.com/compai-lab/2026-GaborDCE-spieker. 2026-08-18T17:48:22Z Accepted at MICCAI Off-Grid Workshop 2026 Veronika Spieker Wenqi Huang Cemre Ariyurek Liam Timms Daniel Rueckert Onur Afacan Julia A. Schnabel Sila Kurugol http://arxiv.org/abs/2608.18867v1 Ultra-wideband MRE of the human liver and spleen for viscoelastic model identification in hepatic inflammation 2026-08-19T12:37:01Z Magnetic resonance elastography (MRE) is established for noninvasive assessment of liver fibrosis. Conventional abdominal MRE is typically limited to 40-60 Hz. Lower frequencies remain largely unexplored, particularly with regard to hepatic inflammation. We developed ultra-wideband MRE covering 5-80 Hz to investigate frequency-resolved viscoelastic dispersion of the liver and spleen and to identify biomechanical markers of hepatic inflammation. Following phantom validation, nine healthy volunteers and nine patients with inflammatory liver disease were examined at 12 frequencies. Spatiotemporal phase unwrapping and frequency-adaptive wavefield preprocessing enabled reconstruction of shear wave speed (SWS), penetration rate (PR), and loss angle ($φ$). Six rheological models were evaluated. The largest inflammation-associated changes were observed at frequencies below 20 Hz: $φ$ increased by 63% (p<0.001), PR decreased by 37% (p=0.003), and SWS increased by 8% (p=0.008), indicating predominantly dissipative, rather than stiffness-related, changes and a shift toward fluid-like behavior with minor stiffness changes in the lower frequency regime. The rheological springpot model with serial dashpot provided the best fit and revealed distinct dispersion functions for liver and spleen. In patients, springpot elastic modulus increased (101%, p=0.001), while viscosity and springpot power-law exponent decreased (52%, p=0.002 and 58%, p<0.001) suggesting a shift from soft-fluid to stiff-solid liver properties. Ultra-wideband MRE revealed that inflammatory liver disease is associated with property shifts toward stronger dissipation and fluid-like behavior at low frequencies while displaying solid-like behavior at higher frequencies. Ultra-low frequency MRE may provide a diagnostic window into inflammation-associated liver viscoelasticity without full rheological modeling. 2026-08-19T12:37:01Z Jakob Schattenfroh Michael Fedders Steffen P. Häseli Tobias Puengel Yanglei Wu Tom Meyer Hossein S. Aghamiry Tim Ricken Münevver Demir Frank Tacke Jing Guo Rolf Reiter Ingolf Sack http://arxiv.org/abs/2603.29671v2 Efficiency limits in in-line imaging 2026-08-19T06:16:08Z In-line phase-contrast imaging, also known as propagation-based imaging or Gabor holography, is capable of delivering significant gains in image quality, compared to attenuation-based imaging at the same radiation dose. Image quality metrics, including signal-to-noise ratio and spatial resolution, are considered, and their relationship to the amount of Shannon information in the image is discussed. It is demonstrated that it is possible to increase the image quality gain by combining known phase retrieval methods with deconvolution of the point-spread function (PSF) of the imaging system, with the highest gain achieved using the Contrast Transfer Function correction method in combination with the PSF deconvolution. The ultimate limit of this gain is determined by the ratio of the real decrement to the imaginary part of the complex refractive index of the imaged sample. Analytical results for the image quality limits in in-line imaging are obtained using a Gaussian model for the detector PSF. A numerically simulated example confirming the theoretical results is also presented. 2026-03-31T12:28:35Z 51 pages, 4 tables, 5 figures Timur E. Gureyev David M. Paganin Harry M. Quiney