https://arxiv.org/api/QxSz1BUjmYWW1zzwddfGzgGDBwU 2026-06-15T08:18:19Z 8970 60 15 http://arxiv.org/abs/2605.28687v1 Cross-modal characterization of infant cry: validation of a chest-surface accelerometer in extracting acoustic vocal function measures 2026-05-27T16:17:25Z Background: Infant cry acoustics provide a promising window into early neurodevelopment and may serve as scalable biomarkers for neurodevelopmental disorders. However, conventional microphone-based recordings are highly susceptible to environmental noise and raise privacy concerns in real-world clinical settings. Chest-surface accelerometers may offer a robust alternative by capturing vibrations directly from the larynx. Methods: We evaluated the validity of a chest-mounted accelerometer (ACC) for infant cry analysis by comparing acoustic features derived from ACC and simultaneously recorded microphone (MIC) signals during routine vaccination visits. The final sample included 85 infants (41 at 4 months; 44 at 12 months) from a diverse pediatric population. Seven vocal measures were extracted from both modalities, including fundamental frequency (F0), jitter, shimmer, cepstral peak prominence (CPP), and harmonics-to-noise ratio (HNR). Agreement and consistency between modalities was assessed using intraclass correlation coefficients (ICCs). Results: F0 demonstrated excellent agreement between ACC and MIC recordings (ICC > 0.94). Jitter measures also showed good-to-excellent agreement, while CPP demonstrated moderate agreement. Shimmer and HNR showed lower absolute agreement and systematic bias between modalities, reflecting possible differences in signal transmission and noise sensitivity. Conclusion: In summary, chest-surface accelerometers can reliably capture several clinically relevant acoustic features of infant cry, particularly temporal measures of F0 and jitter. This approach offers a noise-robust and privacy-preserving alternative to microphone-based recordings, supporting its potential use in scalable clinical and developmental research applications. 2026-05-27T16:17:25Z Winko W. An Saketh Sundar Lisa Yankowitz Daryush D. Mehta Carol L. Wilkinson http://arxiv.org/abs/2605.28016v1 Enhancing Ultra-low-field MRI with Segmentation-guided Adversarial Learning 2026-05-27T06:11:34Z Ultra-low-field (ULF) MRI offers portable and low-cost imaging but suffers from poor image quality. To address this, we present our submission to the 2025 ULF Enhancement Challenge (ULF-EnC), where the goal is to synthesise high-field-like MRIs from 64 mT scans. Our pipeline enhances ULF MRI through a combination of anatomical conditioning and model ensembling. We first generate tissue segmentation priors using a Swin UNETR trained solely on challenge-provided data. These priors condition two independent enhancement networks - a CycleGAN and a transformer-based residual enhancement model (T-REX) - each trained to synthesise 3 T-like MRIs. Outputs from both models are combined using a weighted average. Our approach produces enhanced MRIs that were comparable to high-field scans both quantitatively and qualitatively. 2026-05-27T06:11:34Z James Grover Andrew Phair Michael Ferraro David E. J. Waddington http://arxiv.org/abs/2605.11637v2 Computed Tomography Reconstruction Algorithm Using Markov Random Field Model 2026-05-27T04:52:50Z X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available. 2026-05-12T06:58:44Z 18 pages, 7 figures Taiga Shimomiya Taichi Kusumi Masayuki Uesugi Akihisa Takeuchi Yuki Sada Hayaru Shouno Masato Okada http://arxiv.org/abs/2605.27937v1 Machine learning enables experimental access to photon-by-photon arrival times in scintillation detectors 2026-05-27T04:15:01Z Scintillation detectors with excellent timing resolution enable more precise localization of radiation sources in positron emission tomography, leading to substantial improvements in diagnostic capability for diseases such as cancer and dementia. At the extreme timing precision required for such applications at the picosecond scale, detector performance is governed by the microscopic dynamics of scintillation photons generated within the detector and their subsequent detection processes. However, detector signals have conventionally been treated only as collective responses of many photons due to structural constraints inherent to photodetectors. In this study, we overcome this fundamental limitation using deep learning, enabling direct access to the timing information of individual photons. The proposed method estimates photon-by-photon arrival times directly from detector waveforms without requiring any modification to the detector structure; the method operates on an event-by-event basis without ground-truth labels by integrating an unsupervised learning framework with a physically informed detector-response model. Through comprehensive validation combining Monte Carlo simulation and experimental measurements across various detector configurations, we experimentally demonstrate improved timing resolution, visualized depth-of-interaction-dependent photon transport, and classified Cherenkov and scintillation photons based on the estimated photon-level timing information using a unified deep learning-based framework. These results provide experimental access to photon dynamics, bridging the gap between theoretical modeling and experimental observation, and they open a new data-driven pathway for discovery in detector physics and optimization. 2026-05-27T04:15:01Z Yuya Onishi Ryosuke Ota Fumio Hashimoto Kibo Ote Go Akamatsu Hideaki Tashima Taiga Yamaya http://arxiv.org/abs/2605.27732v1 Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations 2026-05-26T22:10:01Z Pediatric patients with cardiac implantable electronic devices (CIEDs) face limited MRI access due to RF-induced heating, and computational modeling is increasingly used to characterize this risk. The validity of these simulations, however, depends on pairing body models with clinically realistic lead configurations, guidance that is currently lacking. We retrospectively analyzed 302 CIED surgeries in 281 pediatric patients to derive weight-based constraints for simulation design. Weight alone discriminated epicardial from endocardial lead implantation with AUC = 0.90, and adding age and height yielded no improvement, supporting weight as a sufficient single-parameter selection metric. The probabilistic crossover between approaches occurred at 44 kg, substantially higher than the 10 to 15 kg threshold commonly cited in the literature, with a broad transition zone of 21 to 66 kg in which both lead types were routinely used. Lead length was likewise weight-constrained: only 25 cm leads were observed in patients below 6 kg, and leads of 45 cm or longer were uncommon below 50 kg. These findings yield a three-tier framework, with epicardial-only configurations below 21 kg, dual configurations within 21 to 66 kg, and weight-thresholded lead lengths throughout, enabling MRI safety simulations to focus on clinically realizable anatomy and device combinations. 2026-05-26T22:10:01Z Safa Hameed Kaylee Henry Fuchang Jiang Bhumi Bhusal Halley Dillenbeck Lindsey Gakenheimer-Smith Gregory Webster Laleh Golestanirad http://arxiv.org/abs/2604.09157v2 A Fast and Generic Energy-Shifting Transformer for Hybrid Monte Carlo Radiotherapy Calculation 2026-05-26T09:23:04Z We introduce a novel learning framework for accelerated Monte Carlo (MC) dose calculation termed Energy-Shifting. This approach leverages deep learning to synthesize highly complex polyenergetic dose distributions directly from simple monoenergetic inputs under identical beam configurations. Unlike conventional denoising techniques, which rely on noisy low-count dose maps that compromise beam profile integrity, our method achieves superior cross-domain generalization on unseen datasets by integrating high-fidelity anatomical textures and source-specific beam similarity into the model's input space. Furthermore, we propose a novel 3D architecture termed TransUNetSE3D, featuring Transformer blocks for global context and Residual Squeeze-and-Excitation (SE) modules for adaptive channel-wise feature recalibration. Hierarchical representations of these blocks are fused into the network's latent space alongside the primary dose-map parameters, allowing physics-aware reconstruction. This hybrid design outperforms existing UNet and Transformer-based benchmarks in both spatial precision and structural preservation, while maintaining the execution speed necessary for real-time use. Our proposed pipeline achieves a Gamma Passing Rate exceeding 98% (3%/3mm) compared to the MC reference, evaluated within the framework of a treatment planning system (TPS) using 6MV TrueBeam Lineac Accelerator (LINAC) for prostate radiotherapy. These results offer a robust solution for fast volumetric dosimetry in adaptive radiotherapy. 2026-04-10T09:42:41Z 13 pages, 6 figures, 6 tables Chi-Hieu Pham Didier Benoit Vincent Bourbonne Ulrike Schick Dimitris Visvikis Julien Bert http://arxiv.org/abs/2601.13236v2 Pixelwise Uncertainty Quantification of Accelerated MRI Reconstruction 2026-05-25T15:18:10Z Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to automatically assess the diagnostic quality of undersampled reconstructions. This work introduces a general framework for pixel-wise uncertainty quantification in parallel MRI reconstructions, enabling automatic identification of unreliable regions without access to any ground-truth reference image. Our method integrates conformal quantile regression with image reconstruction methods to estimate statistically rigorous pixel-wise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end-to-end Variational Network was used for image reconstruction. Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four-fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler a heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts. The proposed framework enables evaluation of reconstruction quality without access to fully-sampled ground-truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability. 2026-01-19T17:12:28Z 10 pages, 8 figues, 2 tables Ilias I. Giannakopoulos Lokesh B Gautham Muthukumar Yvonne W. Lui Riccardo Lattanzi http://arxiv.org/abs/2606.06507v1 Application of Fractional Polynomial Model Based on Bayesian Criterion in Cerebrovascular Diseases: A Robust Framework for Occlusion Simulation and Topology Reconstruction 2026-05-25T02:59:11Z The internal carotid artery (ICA), especially its cervical segment (ICA-C1), holds significant importance in the diagnosis of cerebrovascular diseases. Traditional polynomial fitting methods often encounter problems such as order selection, overfitting, and oscillation. To address these issues, this paper proposes a fractional polynomial fitting model based on the effective order and Bayesian Information Criterion (BIC). Through statistical analysis, the high-frequency effective orders $\{1.1, 1.5, 2.0, 2.7, 3.4\}$ are determined to improve computational efficiency. The experimental results of 379 clinical cases show that the proposed method outperforms the traditional methods in terms of fitting accuracy, noise resistance and computational efficiency. It can achieve low-error fitting and accurately depict the complex spatial morphology of the ICA-C1 segment. Moreover, by optimizing the solution strategy and sequence selection mechanism, the running time of the algorithm has been reduced from 153.145 seconds to 23.054 seconds. Furthermore, the proposed model shows good application potential in predicting missing vascular segments in imaging tasks. The prediction results are overall stable, and in most cases, the error is small. The normalized mean square error (NMSE) is below 1.68\% in 90\% of the cases. This study presents a stable, efficient and clinically interpretable model approach for analyzing the morphology of cerebral vessels, opening up a new technological frontier for intelligent diagnosis of cerebral vascular diseases. 2026-05-25T02:59:11Z Yu Zhong Luyao Li http://arxiv.org/abs/2605.25139v1 Hybrid Full Waveform Inversion Assisted by Rytov Approximation for Musculoskeletal Ultrasound Computed Tomography 2026-05-24T15:36:53Z Ultrasound computed tomography is emerging as a promising safe and accessible modality for soft-tissue medical imaging, with full waveform inversion playing a key role in unlocking its full potential for high-resolution, quantitative reconstructions. Frequency domain full waveform inversion (FDFWI) for reconstructing spatial maps of acoustic properties in the musculoskeletal system is highly sensitive to the quality of low-frequency signals, making the final imaging outcome vulnerable to issues such as inappropriate initial models and strong scatterings related to bones. To address these challenges, we propose a hybrid full waveform inversion (HFWI) algorithm that incorporates a traveltime inversion algorithm based on the generalized Rytov approximation into the FDFWI framework. This hybrid strategy enhances early-stage inversion quality and substantially reduces sensitivity to the initial model, all while maintaining computational efficiency. Importantly, HFWI achieves results comparable to those obtained using well-constructed initial models, without incurring extra computational cost, thus enabling accurate imaging under realistic, bandwidth-limited conditions. In addition, we introduce a near real-time strategy to update first-arrival traveltimes based on forward-scattered phase variations without requiring extra wavefield simulations. Numerical simulations, as well as \textit{in vitro} and \textit{in vivo} experiments confirm the robustness and efficiency of the proposed approach. HFWI also shows promise to extend to more complex scenarios of musculoskeletal parametric reconstruction. 2026-05-24T15:36:53Z 13 pages, 18 figures; supplementary material included as ancillary file Yifei Sun Yubing Li Chang Su Lekang Jiang Xiangwei Lu Ligang Cui He Sun Weijun Lin http://arxiv.org/abs/2504.00816v5 Two-stage deep learning framework for the restoration of incomplete-ring PET images 2026-05-24T12:16:30Z Positron Emission Tomography (PET) is an important molecular imaging tool widely used in medicine. Traditional PET systems rely on complete detector rings for full angular coverage and reliable data collection. However, incomplete-ring PET scanners have emerged due to hardware failures, cost constraints, or specific clinical needs. Standard reconstruction algorithms often suffer from performance degradation with these systems because of reduced data completeness and geometric inconsistencies. We present a two-stage deep-learning framework that, without incorporating any time-of-flight (TOF) information, restores high-quality images from data with about 50% missing coincidences - double the loss levels previously addressed by CNN-based methods. The pipeline operates in two stages: a projection-domain Attention U-Net first predicts the missing sections of the sinogram by leveraging spatial context from neighbouring slices, after which the completed data are reconstructed with OSEM algorithm and passed to a cascaded U-Net & warm-start diffusion model for image refinement. This module starts the reverse diffusion process from the U-Net coarse prediction rather than pure Gaussian noise. Using 613 simulated brain volumes from real scans (196 healthy brain samples, 217 Alzheimer's disease samples, and 200 Mild Cognitive Impairment samples), the result shows that our model successfully preserves most anatomical structures and tracer distribution features with PSNR of 38.18 to 38.59 dB and SSIM of 0.9904 to 0.9925. Our two-stage deep-learning framework effectively restores high-quality PET images from over 50% incomplete-ring data, achieving near-complete anatomical fidelity and robust performance without requiring TOF information. 2025-04-01T14:05:32Z 17 pages, 5 figures Yeqi Fang Rong Zhou http://arxiv.org/abs/2606.06504v1 Structural gradients and strain partitioning across the mouse Achilles tendon enthesis revealed by in situ X-ray scattering 2026-05-24T06:26:57Z The enthesis is the insertion site of tendon into bone and exhibits a high mechanical durability despite the large mismatch in material properties between the two tissues. This durability stems from gradients in composition, structure and organization on multiple hierarchical length scales. Despite extensive research on enthesis structure and mechanics, the local deformation mechanisms are poorly understood. Synchrotron scanning small- and wide-angle X-ray scattering was combined with in situ tensile testing of the mouse Achilles tendon enthesis to extensively map the mechanical response of the collagen fibrils and molecules as well as the hydroxyapatite mineral particles and crystals. Gradients in nano- and molecular scale structure and a stronger and more immediate deformation response towards the interface compared to further away were observed in both the soft and mineralized tissue. The strain decreased progressively across hierarchical levels; with an applied tissue strain of 20% the nanoscale fibrils were strained by ~1-2%, the collagen molecules by ~0.5% and the hydroxyapatite crystals by ~0.05%, thus following an approximate ratio of 1 : 0.1 : 0.01 : 0.001. These results show that load transfer across the enthesis is both spatially heterogeneous and hierarchy-dependent. This indicates that the graded attachment accommodates deformation through region-specific load sharing and hierarchical strain partitioning, consistent with a contribution from dissipation within the non-collagenous matrix. In doing so, the enthesis can mitigate stress concentrations and maintain mechanical integrity across the tendon-to-bone transition. 2026-05-24T06:26:57Z Isabella Silva Barreto Moritz L. Stammer Moritz P. K. Frewein Claire Camy Juraj Todt Michael Meindlhumer Jozef Keckes Stefano Checchia Sandrine Roffino Martine Pithioux Tilman A. Grünewald http://arxiv.org/abs/2605.24815v1 GRASP MRI: A Decade of Innovation from Bench to Bedside 2026-05-24T02:01:55Z GRASP (Golden-angle RAdial Sparse Parallel) MRI has emerged as one of the most influential motion-robust dynamic MRI frameworks over the past decade. By combining continuous golden-angle radial sampling with compressed sensing and parallel imaging, GRASP enables free-breathing data acquisition with flexible retrospective image reconstruction. Since its original introduction, the framework has evolved substantially and has inspired a broad range of technical developments, including motion-resolved reconstruction, real-time imaging, quantitative MRI, deep learning-enabled reconstruction, and multidimensional cardiovascular imaging. These advances have further expanded the role of GRASP MRI in a range of clinical applications where conventional breath-hold imaging is challenging. This review summarizes the technical evolution and clinical translation of GRASP MRI over the past decade, with a particular focus on the conceptual advantages of continuous radial acquisition, flexible retrospective reconstruction, and motion-robust imaging. Emerging developments in deep learning reconstruction, real-time volumetric imaging, and quantitative free-breathing MRI are also discussed together with future directions of motion-robust MRI acquisition and reconstruction. 2026-05-24T02:01:55Z Li Feng Kai Tobias Block Hersh Chandarana Daniel K Sodickson http://arxiv.org/abs/2605.24791v1 A Wireless Reconfigurable Metasurface for Enhanced Parallel Magnetic Resonance Imaging 2026-05-24T00:30:51Z Modern magnetic resonance imaging (MRI) relies on application-specific multi-channel receive coils to achieve high performance, but these coils are typically costly, rigid, and difficult to generalize across anatomies. Recent wireless, low-cost metamaterials offer improved signal-to-noise ratio (SNR) but remain anatomy-dependent, are prone to destructive inter-element interference, and lack demonstrated compatibility with parallel imaging. Herein, a wireless, reconfigurable coaxial loop metasurface (CLM) is introduced as a platform for localized SNR enhancement that can operate either as a standalone element or as an insertable add-on alongside existing clinical receive systems. Through its coaxial architecture and shared current pathways, the CLM establishes a collective in-phase resonant mode that enforces phase-coherent current distributions across all loops, resulting in consistently constructive interference. Benchmarking on a 3.0 T MR system using an 8-loop CLM shows SNR enhancements of up to 14.8-fold and 14.02-fold in the sagittal and axial planes, relative to the birdcage coil (BC). As an add-on to a clinical posterior receive array, it further demonstrates up to 2.9-fold SNR enhancement and compatibility with parallel imaging across ex vivo and in vivo settings. The proposed CLM paves the way toward a new class of reconfigurable and insertable MRI hardware for flexible and system-compatible signal enhancement. 2026-05-24T00:30:51Z Yuhan Liu Xia Zhu Ke Wu Artem Kaliaev Christina A. LeBedis Stephan W. Anderson Xin Zhang http://arxiv.org/abs/2605.26151v1 Towards Real-World Identification of Fatigued Muscle Groups via Musculoskeletal Simulation 2026-05-23T08:06:09Z Contactless diagnosis of musculoskeletal disorders can potentially improve population health as well as robot behaviours in collaborative settings. However, current diagnosis methods require an in-person physical examination in which a trained physician senses, through contact, the force applied by various muscles. Simulation tools exist, but their use for diagnosis with real data is under-explored. In this paper, we propose an algorithm for identifying which upper-limb muscle group is fatigued. Our algorithm compares the realworld free-space motion of the subject with that of a simulated musculoskeletal model, and is therefore contactless: preventing the need for invasive sensing or in-person assessment. Our algorithm simulates various fatigue conditions using a physics-based musculoskeletal model and extracts diagnostic motion features from both real and simulated data, which are compared for diagnosis. Experimental results on real data demonstrate that the proposed method can reliably distinguish between multiple muscle-groups of fatigue. Additionally, through comprehensive performance comparisons, we show how recent advanced musculoskeletal simulators can be properly configured to address the sim-to-real gap in the context of the fatigue diagnosis task. Our approach can potentially spur further research in remote and automated diagnosis, significantly lowering the barrier to large-scale and early detection. 2026-05-23T08:06:09Z Video File: https://www.youtube.com/watch?v=scvi3DCD9UY Jenishkumar Chauhan Samarth Brahmbhatt Vineet Vashista http://arxiv.org/abs/2605.24201v1 Radiuma: A Unified Zero-Code Executable Graphical Workflow Generator for Reproducible and Shareable Medical Image Analysis and Machine Learning 2026-05-22T20:43:21Z Medical image computing software is essential for identifying imaging biomarkers that can support diagnosis, prognosis, treatment planning, and clinical research. However, the lack of standardized, user-friendly, and reproducible software environments has limited the broader adoption of advanced medical image analysis workflows. We present Radiuma, a freely available modular platform designed to support reliable and reproducible medical image analysis across multiple modalities and file formats. Radiuma integrates image reading, visualization, registration, fusion, processing, segmentation, radiomics feature extraction, and machine learning modules for classification, regression, and clustering. Its modular design allows users to execute each component independently or connect modules through a visual workflow system, where the output of one step can be graphically passed to the next. This enables the creation of custom, executable, and reproducible multi-step pipelines without requiring extensive programming expertise. Results from each module can be inspected directly in the visualization window, providing immediate feedback on processing quality and workflow accuracy. Radiuma also supports saving and sharing customized workflows, promoting transparency, reusability, and consistency across collaborative studies. By combining flexibility, usability, and standardized analysis tools, Radiuma provides a practical environment for radiomics and machine learning research in clinical and translational settings. The platform is designed to be accessible to users with diverse expertise, including radiologists, physicists, clinicians, and data scientists. 2026-05-22T20:43:21Z Mohammad Salmanpour Mehrdad Oveisi Isaac Shiri Arman Rahmim