https://arxiv.org/api/AUmdkCSTfOW0BKdGaztZ0m8QAes2026-06-22T22:33:22Z898558515http://arxiv.org/abs/2512.20065v1Fabrication, drug delivery kinetics and cell viability assay of PLGA-coated vancomycin-loaded silicate porous microspheres2025-12-23T05:34:52ZPorous ceramic microspheres are a desirable substance for bone tissue reconstruction and delivery applications. This study focuses on Mg-Ca silicate microspheres encapsulated in biodegradable poly (lactic-co-glycolic acid) (PLGA) to serve as a biocompatible carrier for the controlled release of vancomycin hydrochloride. In this regard, diopside (MgCaSi2O6), bredigite (MgCa7Si4O16) and akermanite (MgCa2Si2O7) powders were synthesized by sol-gel and subsequent calcination methods. Then, porous akermanite, diopside and bredigite microspheres of 700-1000 um in diameter were fabricated by using carbon porogen, droplet extrusion and sintering, then loaded with the drug and eventually coated with PLGA. The bare microspheres showed a considerable burst release mode of the drug into a physiological medium, whereas PLGA coating of the microspheres reduced the burst release level. To investigate effective mechanisms governing in the drug release from the carriers, the contribution of burst, degradation, and diffusion was analyzed by the sequential quadratic programming algorithm method. It was found that the relative contribution of diffusion to bioresorption is ranked as diopside > akermanite > bredigite, whereas PLGA coating dominates the diffusion mechanism. The dental pulp stem cells cytocompatibility MTT assay of the microspheres also showed that the drug loading deteriorates but PLGA coating improves the cell biocompatibility significantly. Comparatively, the biocompatibility of the PLGA-coated microspheres was ranked as akermanite > diopside > bredigite, as a result of a compromise between the release of the constituting ions of the ceramic carriers and vancomycin molecules. It was eventually concluded that PLGA-coated Mg-Ca silicate microspheres are promising candidates for drug-delivery bone tissue engineering and dental bone grafting applications.2025-12-23T05:34:52ZCeramics International, 48 (2022) 48-54N. ZirakA. MaadaniE. SalahinejadN. AbbasnezhadM. Shirinbayan10.1016/j.ceramint.2021.08.298http://arxiv.org/abs/2512.05877v2Functional dual-slope frequency-domain near-infrared spectroscopy data interpreted with two- and three-layer models2025-12-22T19:34:44ZFunctional near-infrared spectroscopy (fNIRS) is impacted by signal contamination from superficial hemodynamics. It is important to develop methods that account for such contamination and provide accurate measurements of cerebral hemodynamics. This work aims to investigate whether simulated data with two-layer or three-layer tissue models are able to reproduce in vivo data collected with dual-slope (DS) frequency-domain (FD) near-infrared spectroscopy (NIRS) on human subjects during brain activation. We performed Monte Carlo simulations to generate DS FD-NIRS data from two- and three-layer media with a range of layer thicknesses and optical properties. We collected in vivo data with DS FD-NIRS (source-detector distances: 25, 37 mm; wavelengths: 690, 830 nm; modulation frequency: 140 MHz) over the occipital lobe of human subjects during visual stimulation. Simulated and in vivo data were analyzed with diffusion theory for a homogeneous medium and results were compared for each DS FD-NIRS data type. We found that the main qualitative features of in vivo data could be reproduced by simulated data from a three-layer medium, with a second layer (representing the cerebrospinal fluid in the subarachnoid space) that is less absorbing and less scattering than the other two layers, and with a top layer thickness that represents the combined scalp and skull thickness. A three-layer model is a viable improvement over a homogeneous model to analyze DS FD-NIRS data (or any other fNIRS data) to generate more accurate measurements of cerebral hemodynamic changes without a need for large data sets for tomographic reconstructions.2025-12-05T16:54:21Z37 pages, 10 figuresJodee FriasGiles BlaneyAngelo SassaroliSergio Fantini10.1117/1.BIOS.3.2.025003http://arxiv.org/abs/2512.19584v1Patlak Parametric Image Estimation from Dynamic PET Using Diffusion Model Prior2025-12-22T17:11:33ZDynamic PET enables the quantitative estimation of physiology-related parameters and is widely utilized in research and increasingly adopted in clinical settings. Parametric imaging in dynamic PET requires kinetic modeling to estimate voxel-wise physiological parameters based on specific kinetic models. However, parametric images estimated through kinetic model fitting often suffer from low image quality due to the inherently ill-posed nature of the fitting process and the limited counts resulting from non-continuous data acquisition across multiple bed positions in whole-body PET. In this work, we proposed a diffusion model-based kinetic modeling framework for parametric image estimation, using the Patlak model as an example. The score function of the diffusion model was pre-trained on static total-body PET images and served as a prior for both Patlak slope and intercept images by leveraging their patch-wise similarity. During inference, the kinetic model was incorporated as a data-consistency constraint to guide the parametric image estimation. The proposed framework was evaluated on total-body dynamic PET datasets with different dose levels, demonstrating the feasibility and promising performance of the proposed framework in improving parametric image quality.2025-12-22T17:11:33Z10 pages, 9 figuresZiqian HuangBoxiao YuSiqi LiSavas OzdemirSangjin BaeJae Sung LeeGuobao WangKuang Gonghttp://arxiv.org/abs/2512.19470v1MRI Simulation and Reconstruction Framework for Magnetic Vector Fields2025-12-22T15:23:41ZPurpose: Conventional MRI is relying on the assumption of the magnetic field being homogeneous in direction and amplitude. However, with the growing interest in portable, affordable point-of-care MRI systems, these assumptions do not necessarily hold anymore due to compromises necessary to achieve a reduction in e.g. footprint, weight and portability. Simulation software may help by evaluating new encoding schemes which are optimized for non-ideal hardware but also with the design of new scanner designs. The goal of this work was to develop a MATLAB-based simulation software capable of dealing with deflected magnetic fields during signal simulation and reconstruction and enabling the evaluation of arbitrary magnetic field configurations for encoding in MRI.
Methods: Conventional matrix-based Bloch simulation is limited in its applicability to arbitrary magnetic fields. We therefore adapted, evaluated, and validated a modified approach, achieving substantially shorter simulation time. Furthermore, it is used to predict image quality in 2D gradient echo experiments with deflected magnetic fields.
Results: The comparison of numerical Bloch and matrix-based simulation revealed close agreement of both reconstructed images. Further, it was shown that compensation of the associated artifacts can be achieved by incorporating knowledge about the used magnetic fields into the reconstruction process.
Conclusion: The presented and validated software package enables full consideration of angular inhomogeneities of magnetic vector fields used in MRI for signal simulation but also reconstruction removing the related artifacts. As such, the software might become a valuable tool for new low-field system designs and the investigation of new reconstruction algorithms.2025-12-22T15:23:41Z22 pages, 10 figures, associated Code, see https://github.com/ExCaVI-Ulm/MRISimVecFieldFabian BschorrThomas HüfkenTobias LobmeyerVolker Rasche10.1016/j.zemedi.2026.02.002http://arxiv.org/abs/2512.19188v1Deformation and Stress Evolution during Laser Powder Bed Fusion of Semi-Crystalline Polyamide-122025-12-22T09:21:14ZLaser powder bed fusion (L-PBF) of semi-crystalline polymers such as polyamide-12 (PA12) has found increasing use in various industrial applications. However, achieving high dimensional accuracy remains a significant challenge. Despite the seemingly straightforward layer-by-layer manufacturing concept, the L-PBF process involves complex thermal histories and strongly coupled multiphysics, making the evolution of stress and deformation mechanisms still not fully understood. To address this, a comprehensive three-dimensional thermo-mechanical modeling framework is developed to simulate the L-PBF process of PA12. The model for the first time incorporates transient heat transfer, phase transformation induced volumetric shrinkage, thermoviscoelasticity, and a modified non-isothermal crystallization kinetics. To alleviate the computational burden of part-scale simulations, a dual-mesh strategy is employed to efficiently couple thermal and mechanical fields without compromising numerical accuracy, which also enables the framework to handle L-PBF simulations of arbitrarily complex three-dimensional geometries. Particular attention is paid to the role of mechanical and thermal boundary conditions. Specifically, the underlying powder bed is modeled as a fictitious viscous medium, providing support while permitting upward displacement. Additionally, a radiative heat loss boundary condition, which more closely approximates the actual physical process, is applied to the top powder surface. The incorporation of this radiation effect significantly enhances the crystallization rate and improves the agreement with experimentally measured warpage. The model is validated against experimental warpage data under various preheating temperatures. Furthermore, strain decoupling analysis for the first time reveals that displacement induced by phase transformation is approximately 10 times greater than that caused by thermal expansion, highlighting the dominant role of crystallizationinduced shrinkage in warpage formation. Numerical tests also indicate that warpage is highly sensitive to the preheating target temperature of the PA12 powder bed, while the temperature of the newly recoated powder within the tested range has a limited effect. This work provides a predictive modeling foundation for future optimization of polymer L-PBF processes at part-scale, particularly in controlling deformation and improving dimensional accuracy.2025-12-22T09:21:14ZAdditive Manufacturing, 2025Zhongfeng XuCEMEFWei ZhuCEMEFLionel FreireCEMEFNoëlle BillonCEMEFJean-Luc BouvardCEMEFYancheng ZhangCEMEFhttp://arxiv.org/abs/2512.19143v1Classical and relativistic balance of configurational forces2025-12-22T08:42:16ZThis article develops a unified variational framework for configurational (or material) forces in both Classical (3D, non-relativistic) and Relativistic (4D) Continuum Mechanics. Configurational forces describe the evolution of material defects-such as cracks, dislocations, and interfaces-which move relative to the material rather than through physical space. In the classical setting of hyperelasticity, the authors revisit the balance of configurational forces using an intrinsic Lagrangian formulation, where the material body is modeled as an abstract three-dimensional manifold. By treating the reference configuration as a variable and performing a Lagrangian variation with respect to it, they show that the configurational forces balance naturally emerges. Importantly, this balance equation is not independent: it is equivalent to the standard balance of linear momentum combined with constitutive relations, and it is expressed through the Eshelby stress tensor on the reference configuration. The framework is then extended to Relativistic Hyperelasticity within General Relativity. Matter is described by a matter field, a vector valued function, defined on the four-dimensional Universe, and the Lagrangian (i.e., Action) includes both matter and gravitational contributions. Two stress-energy tensors arise: the Noether stress-energy tensor (from variations with respect to the matter field) and the Hilbert stress-energy tensor (from variations with respect to the Universe metric). Assuming General Covariance, the authors prove that these tensors and their associated balance laws are equivalent. By introducing the notion of an observer and specializing to static spacetimes, the authors define a relativistic generalization of the deformation and derive a four-dimensional Eshelby tensor. They show that in Special Relativity, as in Classical Continuum Mechanics, the relativistic configurational forces balance is not a new equation but follows from the conservation laws of the Noether stress-energy tensor. Finally, they recover the classical configurational forces balance as the non-relativistic limit of the relativistic theory. Overall, the paper provides a rigorous geometric and variational interpretation of configurational forces, unifying classical and relativistic formulations and clarifying their deep connection with standard equilibrium equations.2025-12-22T08:42:16ZRodrigue DesmoratLMPSAnthony GravouilLaMCoSBoris KolevLMPShttp://arxiv.org/abs/2512.19055v1Enhanced Vascularity in Gelatin Scaffolds via Copper-Doped Magnesium-Calcium Silicates Incorporation: In-Vitro and Ex-Ovo Insights2025-12-22T05:44:44ZAddressing a critical challenge in current tissue-engineering practices, this study aims to enhance vascularization in 3D porous scaffolds by incorporating bioceramics laden with pro-angiogenic ions. Specifically, freeze-dried gelatin-based scaffolds were infused with sol-gel-derived powders of Cu-doped akermanite (Ca2MgSi2O7) and bredigite (Ca7MgSi4O16) at various concentrations (10, 20, and 30 wt%). The scaffolds were initially characterized for their structural integrity, biodegradability, swelling behavior, impact on physiological pH, and cytocompatibility with human umbilical vein endothelial cells (HUVECs). The silicate incorporation effectiveness in promoting vascularity was then assessed through HUVEC attachment, capillary tube formation, and ex-ovo chick embryo chorioallantoic membrane assays. The findings revealed significant improvements in both in-vitro and ex-ovo vascularity of the gelatin scaffolds upon the addition of Cu-doped akermanite. The most effective concentrations were determined to be 10 and 20%, which led to notable HUVEC metabolic activity, a well-spread morphology with extensive peripheral filopodia and lamellipodia at 10% and a cobblestone phenotype indicative of in-vivo endothelium at 20% during cell attachment, the formation of complex networks of tubular structures, and robust vascularization in chick embryo development. Moving forward, the incorporation of Cu-doped akermanite into tissue-engineering scaffolds shows great potential for addressing the limitations of vascularization, especially for critical-sized bone defects, by facilitating the controlled release of pro-angiogenic and pro-osteogenic ions.2025-12-22T05:44:44ZCeramics International, 50 (2024) 39889-39897Erfan SalahinejadAvaneesh MuralidharanForough Azam SayahpourMaryam KianpourMohsen AkbarianDaryoosh VashaeeLobat Tayebi10.1016/j.ceramint.2024.07.369http://arxiv.org/abs/2512.19014v1Enhanced sinterability and in vitro bioactivity of diopside through fluoride doping2025-12-22T04:06:46ZIn this work, diopside (CaMgSi2O6) was doped with fluoride at a level of 1 mol.%, without the formation of any second phase, by a wet chemical precipitation method. The sintered structure of the synthesized nanopowders was studied by X-ray diffraction, Fourier transform infrared spectroscopy and field-emission scanning electron microscopy. Also, the samples' in vitro apatite-forming ability in a simulated body fluid was comparatively evaluated by electron microscopy, inductively coupled plasma spectroscopy and Fourier transform infrared spectroscopy. According to the results, the material's sinterability was improved by fluoride doping, as realized from the further development of sintering necks. It was also found that compared to the undoped bioceramic, a higher amount of apatite was deposited on the surface of the doped sample. It is concluded that fluoride can be considered as a doping agent in magnesium-containing silicates to improve biological, particularly bioactivity, behaviors.2025-12-22T04:06:46ZCeramics International, 43 (2017) 4680-4686E. SalahinejadM. Jafari Baghjeghaz10.1016/j.ceramint.2016.12.144http://arxiv.org/abs/2512.18863v1A physics-informed, plug-and-play dose engine for gradient-based radiotherapy treatment planning2025-12-21T19:36:09ZRadiotherapy treatment planning remains a time-intensive iterative process requiring expert intervention in commercial treatment planning system (TPS). While machine learning approaches have demonstrated promise, most remain depedent on TPS-based dose calculation or surrogate dose models, preventing direct optimization of deliverable treatment plan parameters.
We propose PyDoseRT (PDRT), a physics-informed, GPU-accelerated dose engine implemented in PyTorch that computes dose distributions directly from treatment delivery parameters (i.e., MLC leaf positions, jaw positions, gantry angles, and monitor units). The engine preserves gradient information throughout the dose computation pipeline, enabling gradient-based optimization of hardware-constrained treatment plans without the reliance on a commercial TPS.
PDRT was evaluated on 19 and 162 clinical VMAT prostate cancer plans from two hospitals (with different treatment machines). When recalculating clinical plans, PDRT achieved high 3D gamma pass rates (mean 96.8% for 2%/2 mm and 98.9% for 3%/3 mm, depending on cohort). All optimized plans converged to clinically acceptable solutions and passed deliverability verification when imported into a commercial TPS.
This physics-informed framework eliminates TPS dependency for radiotherapy optimization research by enabling gradient-based planning while ensuring that delivery parameters remain in the machine-feasible range. The gradient-enabled dose engine allows exploration of novel optimization strategies and objective functions while maintaining clinical validity. The proposed approach provides a research platform for investigating real-time adaptive radiotherapy concepts, automated planning workflows, and TPS-independent optimization strategies, and democratizing radiotherapy research, by exposing gradient-enabled, hardware-aware, open-source dose computation.2025-12-21T19:36:09ZAttila SimkóMatthias KronsteinerSimon GlatzerMinh VuJosef A. LundmanJoakim JonssonJörgen OlofssonKristina SandgrenWolfgang LechnerDietmar GeorgTommy LöfstedtTufve NyholmAnders GarpebringGerd Heilemannhttp://arxiv.org/abs/2308.02815v2An AI-driven Assessment of Bone Density as a Biomarker Leading to the Aging Law2025-12-19T09:43:02ZAs global population aging intensifies, there is growing interest in the study of biological age. Bones have long been used to evaluate biological age, and the decline in bone density with age is a well-recognized phenomenon in adults. However, the pattern of this decline remains controversial, making it difficult to serve as a reliable indicator of the aging process. Here we present a novel AI-driven statistical method to assess the bone density, and a discovery that the bone mass distribution in trabecular bone of vertebrae follows a non-Gaussian, unimodal, and skewed distribution in CT images. The statistical mode of the distribution is defined as the measure of bone mass, which is a groundbreaking assessment of bone density, named Trabecular Bone Density (TBD). The dataset of CT images are collected from 1,719 patients who underwent PET/CT scans in three hospitals, in which a subset of the dataset is used for AI model training and generalization. Based upon the cases, we demonstrate that the pattern of bone density declining with aging exhibits a consistent trend of exponential decline across sexes and age groups using TBD assessment. The developed AI-driven statistical method blazes a trail in the field of AI for reliable quantitative computation and AI for medicine. The findings suggest that human aging is a gradual process, with the rate of decline slowing progressively over time, which will provide a valuable basis for scientific prediction of life expectancy.2023-08-05T08:11:26ZLinmi TaoDonglai TaoRuiyang LiuYu ChengYuezhi ZhouLi HuoZuoxiang HeTi JiangJingmao CuiYuanbiao WangGuilan HuXiangsong ZhangYongwei PanYe YuanYun Liuhttp://arxiv.org/abs/2512.15482v2Multiscale modeling of blood circulation with cerebral autoregulation and network pathway analysis for hemodynamic redistribution in the vascular network with anatomical variations and stenosis conditions2025-12-19T04:52:29ZCerebral hemodynamics is fundamentally regulated by the Circle of Willis (CoW), which redistributes flow through communicating arteries to stabilize perfusion under anatomical variations and vascular stenosis. In this study, we develop a multiscale circulation model by coupling a systemic hemodynamic framework with a cerebral arterial network reconstructed from medical imaging. The model incorporates a cerebral autoregulation mechanism (CAM) and enables quantitative simulation of flow redistribution within the CoW under normal, anatomically varied, and stenotic conditions. Baseline simulations reproduce physiological flow distributions in which communicating arteries remain nearly inactive, showing negligible cross-flow and agreement with clinical measurements. In contrast, anatomical variations reveal distinct collateral activation patterns: the anterior communicating artery (ACoA) emerges as the earliest and most sensitive functional collateral, whereas the posterior communicating arteries (PCoAs) exhibit structure-dependent engagement. Progressive stenosis simulations further demonstrate a transition from a complete CoW to a fetal-type posterior cerebral artery (PCA) configuration, characterized by early ACoA flow reversal followed by ipsilateral PCoA activation, consistent with experimental and transcranial Doppler observations. Finally, a path-based quantitative analysis is introduced to illustrate how the cerebral vascular network dynamically reconfigures collateral pathways in response to structural changes. Overall, the proposed framework provides a physiologically interpretable, image-informed tool for investigating cerebral flow regulation through functional collaterals within the CoW, with potential applications in the diagnosis and treatment planning of cerebrovascular diseases.2025-12-17T14:34:18Z34 pages, 9 figuresJiawei LiuAtsushi KanokeHidenori EndoKuniyasu NiizumaHiroshi Suitohttp://arxiv.org/abs/2512.22176v1Field strength-dependent performance variability in deep learning-based analysis of magnetic resonance imaging2025-12-18T23:50:06ZThis study quantitatively evaluates the impact of MRI scanner magnetic field strength on the performance and generalizability of deep learning-based segmentation algorithms. Three publicly available MRI datasets (breast tumor, pancreas, and cervical spine) were stratified by scanner field strength (1.5T vs. 3.0T). For each segmentation task, three nnU-Net-based models were developed: A model trained on 1.5T data only (m-1.5T), a model trained on 3.0T data only (m-3.0T), and a model trained on pooled 1.5T and 3.0T data (m-combined). Each model was evaluated on both 1.5T and 3.0T validation sets. Field-strength-dependent performance differences were investigated via Uniform Manifold Approximation and Projection (UMAP)-based clustering and radiomic analysis, including 23 first-order and texture features. For breast tumor segmentation, m-3.0T (DSC: 0.494 [1.5T] and 0.433 [3.0T]) significantly outperformed m-1.5T (DSC: 0.411 [1.5T] and 0.289 [3.0T]) and m-combined (DSC: 0.373 [1.5T] and 0.268[3.0T]) on both validation sets (p<0.0001). Pancreas segmentation showed similar trends: m-3.0T achieved the highest DSC (0.774 [1.5T], 0.840 [3.0T]), while m-1.5T underperformed significantly (p<0.0001). For cervical spine, models performed optimally on same-field validation sets with minimal cross-field performance degradation (DSC>0.92 for all comparisons). Radiomic analysis revealed moderate field-strength-dependent clustering in soft tissues (silhouette scores 0.23-0.29) but minimal separation in osseous structures (0.12). These results indicate that magnetic field strength in the training data substantially influences the performance of deep learning-based segmentation models, particularly for soft-tissue structures (e.g., small lesions). This warrants consideration of magnetic field strength as a confounding factor in studies evaluating AI performance on MRI.2025-12-18T23:50:06Z16 pages, 1 table, 4 figuresMuhammad Ibtsaam QadirDuane SchonlauUlrike DydakFiona R. Kolbingerhttp://arxiv.org/abs/2408.14607v2Patient-specific prediction of regional lung mechanics in ARDS patients with physics-based models: a validation study2025-12-18T22:35:34ZThe choice of lung protective ventilation settings for mechanical ventilation has a considerable impact on patient outcome, yet identifying optimal ventilatory settings for individual patients remains highly challenging due to the inherent inter- and intra-patient pathophysiological variability. In this validation study, we demonstrate that physics-based computational lung models tailored to individual patients can resolve this variability, allowing us to predict the otherwise unknown local state of the pathologically affected lung during mechanical ventilation. For seven ARDS patients undergoing invasive mechanical ventilation, physics-based, patient-specific lung models were created using chest CT scans and ventilatory data. By numerically resolving the interaction of the pathological lung with the airway pressure and flow imparted by the ventilator, we predict the time-dependent and heterogeneous local state of the lung for each patient and compare it against the regional ventilation obtained from bedside monitoring using Electrical Impedance Tomography. Excellent agreement between numerical simulations and experimental data was obtained, with the model-predicted anteroposterior ventilation profile achieving a Pearson correlation of 96% with the clinical reference data. Even when considering the regional ventilation within the entire transverse chest cross-section and across the entire dynamic ventilation range, an average correlation of more than 81% and an average root mean square error of less than 15% were achieved. The results of this first systematic validation study demonstrate the ability of computational models to provide clinically relevant information and thereby open the door for a truly patient-specific choice of ventilator settings on the basis of both individual anatomy and pathophysiology.2024-08-26T20:04:34Z11 pages, 9 figuresMaximilian RixnerMaximilian LudwigMatthias LindnerInéz FrerichsArmin SablewskiKarl-Robert WichmannMax-Carl WachterKei W. MüllerDirk SchädlerWolfgang A. WallJonas BiehlerTobias Becherhttp://arxiv.org/abs/2512.16800v1A parallel, pipeline-based online analysis system for Interaction Vertex Imaging2025-12-18T17:32:01ZObjective
Interaction vertex imaging (IVI) is used for range monitoring in carbon ion radiotherapy, detecting depth differences between Bragg peak positions. Online range monitoring, which provides feedback during beam delivery, is particularly desirable, creating an opportunity to detect range errors before the treatment fraction is completed. Incorporating online range monitoring into clinical workflows may therefore improve the safety and consistency of radiotherapy.
Approach
The data analysis system was broken into a task-parallel pipeline approach, to allow multiple analysis stages to occur concurrently, beginning during acquisition. Computationally-expensive operations were further parallelized to reduce bottleneck effects. Data collected from irradiation of homogeneous plastic phantoms was replayed at the same rate it was initially acquired, to mimic data acquisition, and the time required to determine a range shift was measured.
Main Results
With an optimized pipeline, the delay between the end of irradiation and the determination of a range shift is consistently less than 200 ms. The majority of this time is associated with the final range shift determination, with a minor effect from the time required to analyze the last data packet. The most significant contribution to an optimized analysis workflow is the formation of clusters, requiring almost 50% of compute time.
Significance
This system is the first IVI implementation to achieve clinically-relevant online analysis times. The 200 ms time required to determine a range shift is less than the time required to accelerate a new spill in a synchrotron, and is comparable to the time required for reacceleration if multiple energies are delivered in the same spill. Clinical implementation of online range monitoring would allow treatment to be quickly paused or aborted if significant range errors are detected.2025-12-18T17:32:01Z28 pages, 10 figuresDevin HymersInstitute for Nuclear Physics, University of Cologne, Cologne, GermanySebastian SchroederInstitute for Nuclear Physics, University of Cologne, Cologne, GermanyOlga BertiniGSI GmbH, Darmstadt, GermanyJohann HeuserGSI GmbH, Darmstadt, GermanyJoerg LehnertGSI GmbH, Darmstadt, GermanyChristian Joachim SchmidtGSI GmbH, Darmstadt, GermanyDennis MücherInstitute for Nuclear Physics, University of Cologne, Cologne, Germanyhttp://arxiv.org/abs/2512.16798v1Clinical beam test of inter- and intra-fraction relative range monitoring in carbon ion radiotherapy2025-12-18T17:29:28ZInteraction Vertex Imaging (IVI) is used for range monitoring (RM) in carbon ion radiotherapy. The purpose of RM is to measure the Bragg peak (BP) position for each contributing beam, and detect any changes. Currently, there is no consensus on a clinical RM method, the use of which would improve the safety and consistency of treatment. The prototype filtered IVI (fIVI) Range Monitoring System is the first system to apply large-area and high-rate-capable silicon detectors to IVI. Two layers of these detectors track prompt secondary fragments for use in RM. This device monitored 16 cm and 32 cm diameter cylindrical plastic phantoms irradiated by clinical carbon ion beams at the Heidelberg Ion Beam Therapy Center. Approximately 20 different BP depths were delivered to each phantom, with a minimum depth difference of 0.8 mm and a maximum depth difference of 51.9 mm and 82.5 mm respectively. For large BP range differences, the relationship between the true depth difference and that measured by fIVI is quadratic, although for small differences, the deviation from a linear relationship with a slope of 1 is negligible. RM performance is strongly dependent on the number of tracked particles, particularly in the clinically-relevant regime. Significant performance differences exist between the two phantoms, with millimetric precision at clinical doses being achieved only for the 16 cm phantom. The performance achieved by the prototype fIVI Range Monitoring System is consistent with previous investigations of IVI, despite measuring at more challenging shallow BP positions. Further significant improvements are possible through increasing the sensitive area of the tracking system beyond the prototype, which will both allow an improvement in precision for the most intense points of a scanned treatment plan and expand the number of points for which millimetric precision may be achieved.2025-12-18T17:29:28Z24 pages, 9 figuresDevin HymersInstitute for Nuclear Physics, University of Cologne, Cologne, GermanySebastian SchroederInstitute for Nuclear Physics, University of Cologne, Cologne, GermanyOlga BertiniGSI GmbH, Darmstadt, GermanyStephan BronsHeidelberg Ion Beam Therapy CentreJohann HeuserGSI GmbH, Darmstadt, GermanyJoerg LehnertGSI GmbH, Darmstadt, GermanyChristian Joachim SchmidtGSI GmbH, Darmstadt, GermanyDennis MücherInstitute for Nuclear Physics, University of Cologne, Cologne, Germany