https://arxiv.org/api/cilzNAbkis2VLV6qK2B7OIBkyq0 2026-06-22T21:31:05Z 8985 570 15 http://arxiv.org/abs/2512.22674v1 Semantic contrastive learning for orthogonal X-ray computed tomography reconstruction 2025-12-27T18:33:37Z X-ray computed tomography (CT) is widely used in medical imaging, with sparse-view reconstruction offering an effective way to reduce radiation dose. However, ill-posed conditions often result in severe streak artifacts. Recent advances in deep learning-based methods have improved reconstruction quality, but challenges still remain. To address these challenges, we propose a novel semantic feature contrastive learning loss function that evaluates semantic similarity in high-level latent spaces and anatomical similarity in shallow latent spaces. Our approach utilizes a three-stage U-Net-based architecture: one for coarse reconstruction, one for detail refinement, and one for semantic similarity measurement. Tests on a chest dataset with orthogonal projections demonstrate that our method achieves superior reconstruction quality and faster processing compared to other algorithms. The results show significant improvements in image quality while maintaining low computational complexity, making it a practical solution for orthogonal CT reconstruction. 2025-12-27T18:33:37Z This paper is accepted by Fully3D 2025 Jiashu Dong Jiabing Xiang Lisheng Geng Suqing Tian Wei Zhao http://arxiv.org/abs/2512.22486v1 Morphology-Preserving Holotomography: Quantitative Analysis of 3D Organoid Dynamics 2025-12-27T06:07:09Z Organoids are three-dimensional (3D) in vitro models for studying tissue development, disease progression, and physiological responses. Holotomography (HT) enables long-term, label-free imaging of live organoids by reconstructing volumetric refractive-index (RI) maps, but quantitative analysis is limited by the missing-cone artifact, which introduces anisotropic resolution and axial distortion. Here, we present a quantitative analysis framework that addresses the missing-cone problem at the level of image representation rather than reconstruction. We introduce morphology-preserving holotomography (MP-HT), a torus-shaped spatial filtering strategy that emphasizes high-spatial-frequency RI texture while suppressing low-frequency components most susceptible to missing-cone-induced distortion. Based on MP-HT, we develop a 3D segmentation pipeline for robust separation of epithelial and luminal structures, together with a model-based RI quantification approach that incorporates the system point spread function to enable morphology-independent estimation of dry-mass density and total dry mass. We apply the framework to long-term imaging of live hepatic organoids undergoing expansion, collapse, and fusion. The results demonstrate consistent segmentation across diverse geometries and reveal coordinated epithelial-lumen remodeling, breakdown of morphometric homeostasis during collapse, and transient biophysical fluctuations during fusion. Overall, this work establishes a physically transparent and reproducible approach for quantitative, label-free analysis of organoid dynamics in three dimensions. 2025-12-27T06:07:09Z ChulMin Oh Jimin Cho Juyeon Park Hoyeon Lee YongKeun Park http://arxiv.org/abs/2512.22093v1 A Minimal Network of Brain Dynamics: Hierarchy of Approximations to Quasi-critical Neural Network Dynamics 2025-12-26T17:42:04Z We present an interacting branching model of neural network dynamics, incorporating key biological features such as inhibition with several types of inhibitory interactions. We establish a hierarchy of analytical mean-field approximations to the model, which characterizes nonequilibrium phase transitions between disorder and ordered phases, and perform a stability analysis. Generically, inhibitory neurons increase the stability of the model dynamics. The model is consistent with the quasi-criticality hypothesis in that it displays regions of maximal dynamical susceptibility and maximal mutual information predicated on the strength of the external stimuli. Directed percolation emerges as the universality class of the critical transition of the model, consistent with some previous experimental data and models. In the unstable phase, chaotic dynamics emerge, which may be linked to the occurrence of epileptic seizures. 2025-12-26T17:42:04Z 26 pages, 20 figures Jeremy B. Goetz Naruepon Weerawongphrom Rashid V. Williams-García John M. Beggs Gerardo Ortiz http://arxiv.org/abs/2412.13262v2 Optical Coherence Elastography Measures Mechanical Tension in the Lens and Capsule 2025-12-25T18:33:31Z Lens tension is essential for accommodative vision but remains difficult to measure with precision. Here, we present an optical coherence elastography (OCE) technique that quantifies both tension and elastic modulus in the lens capsule and underlying tissue. This method derives mechanical parameters from surface wave dispersion across a critical frequency range of 1-30 kHz. Using isolated lenses from six-month-old pigs, we measured intrinsic anterior capsular tensions of 0-20 kPa and posterior capsular tensions of 40-50 kPa, induced by intra-lenticular pressure at the cortical surface. The mean shear moduli of anterior and posterior capsules were 630 kPa and 400 kPa, respectively, nearly 100-fold greater than that of the cortical tissues, where tensions were below 1 kPa. Biaxial zonular stretching (~4% strain) increased anterior capsular tension by 67 kPa, with a low uncertainty of only 2 kPa. This optical method holds significant promise for diagnosing and managing accommodative dysfunctions through lens mechanics assessment in clinical settings. 2024-12-17T19:00:07Z The code for computing wave dispersion has been made publicly available at: https://github.com/JanYxuan/Bilayer-wave-dispersion.git Xu Feng Guo-yang Li Yuxuan Jiang Owen Shortt-Nguyen Seok-Hyun Yun 10.1016/j.actbio.2025.05.009 http://arxiv.org/abs/2512.22292v1 Quantitative acoustic monitoring of ensembles of weakly nonlinear microbubble oscillations in optically inaccessible environments 2025-12-25T15:57:30Z A growing class of ultrasound-mediated diagnostic and therapeutic technologies, including sonoporation and blood-brain barrier modulation, relies on microbubble contrast agents, where precise control of microbubble dynamics governs biological responses, efficiency, and safety. However, quantitative monitoring of microbubble oscillations in the stable, weakly nonlinear regime remains challenging, particularly in optically opaque and deep-tissue environments. Here, we introduce a linear acoustic wave propagation and superposition (LAWPS) framework that reconstructs microbubble radius-time dynamics directly from passively recorded acoustic emissions. By coupling Fourier-series representations of weakly nonlinear oscillations with linear monopole radiation theory, LAWPS extends classical monopole models to establish a reversible relationship between multi-frequency acoustic emissions and underlying radial bubble dynamics. Extending this framework to monodisperse microbubble ensembles, we derive optimal excitation and receive configurations and population-level correction factors that enable quantitative reconstruction of the ensemble-averaged microbubble dynamics. Using simultaneous optical and acoustic measurements, we demonstrate recovery of microbubble oscillations with ~5% relative error for oscillation amplitudes up to ~15% of equilibrium radius. Finally, we show that oscillations within the framework's operating regime (20% oscillation) generate sonoporation-relevant mechanical stress in vesicles as small as 10 micrometers (capillary number > 0.01), under physiologically relevant conditions. Together, this work establishes a quantitative framework for acoustic emission-based monitoring of weakly nonlinear microbubble oscillations in clinically relevant, optically inaccessible environments to enable improved control of emerging ultrasound diagnostic and therapeutic technologies. 2025-12-25T15:57:30Z 22 pages, 6 figures, 5 supplementary figures Hohyun Lee Reza Pakdaman Zangabad Chulyong Kim Victor Menezes Juyoung Park F. Levent Degertekin Costas Arvanitis http://arxiv.org/abs/2512.17397v2 Eliminating the irregular surface layer of anodically-grown Ni-Ti-O nanopore arrays in a two-stage anodization 2025-12-24T22:08:45Z Nanopores (NPs) grown by anodizing can be partially hidden beneath a relatively compact surface oxide layer, which limits the volumetric surface area of these nanostructures. In this work, nitinol (NiTi) alloy was anodized in an electrolyte containing ethylene glycol, water, and sodium chloride in static and stirred electrolyte stages with the aim of removing the irregular surface array while achieving a thick NP layer. Electron micrographs showed that anodization in the static electrolyte provides a controlled thickness of NP layers covered by an irregular surface layer. In contrast, anodizing in the stirred electrolyte reduced the thickness and the degree of irregularity, which were controlled by the different kinetics of dissolution at the tops, perimeters and bottoms of NPs. To benefit simultaneously from the thickness and regularity of the oxide layers, two-stage anodizing under static and then stirred electrolyte conditions was found to be effective. Following a 30 min anodization in the static electrolyte, anodizing for 30 min under the stirred conditions provided the highest regularity in the oxide array, resulting in NPs of almost 40 nm and 11 μm in diameter and layer thickness, respectively. Two-stage anodizing under static then stirred electrolyte conditions is proposed in order to promote NP structures for applications demanding higher surface areas. 2025-12-19T09:47:58Z Surface and Coatings Technology, 405 (2021) 126707 S. A. Mousavi A. Moshfeghi F. Davoodian E. Salahinejad 10.1016/j.surfcoat.2020.126707 http://arxiv.org/abs/2512.21389v1 Deep learning-enhanced dual-mode multiplexed optical sensor for point-of-care diagnostics of cardiovascular diseases 2025-12-24T19:11:14Z Rapid and accessible cardiac biomarker testing is essential for the timely diagnosis and risk assessment of myocardial infarction (MI) and heart failure (HF), two interrelated conditions that frequently coexist and drive recurrent hospitalizations with high mortality. However, current laboratory and point-of-care testing systems are limited by long turnaround times, narrow dynamic ranges for the tested biomarkers, and single-analyte formats that fail to capture the complexity of cardiovascular disease. Here, we present a deep learning-enhanced dual-mode multiplexed vertical flow assay (xVFA) with a portable optical reader and a neural network-based quantification pipeline. This optical sensor integrates colorimetric and chemiluminescent detection within a single paper-based cartridge to complementarily cover a large dynamic range (spanning ~6 orders of magnitude) for both low- and high-abundance biomarkers, while maintaining quantitative accuracy. Using 50 uL of serum, the optical sensor simultaneously quantifies cardiac troponin I (cTnI), creatine kinase-MB (CK-MB), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) within 23 min. The xVFA achieves sub-pg/mL sensitivity for cTnI and sub-ng/mL sensitivity for CK-MB and NT-proBNP, spanning the clinically relevant ranges for these biomarkers. Neural network models trained and blindly tested on 92 patient serum samples yielded a robust quantification performance (Pearson's r > 0.96 vs. reference assays). By combining high sensitivity, multiplexing, and automation in a compact and cost-effective optical sensor format, the dual-mode xVFA enables rapid and quantitative cardiovascular diagnostics at the point of care. 2025-12-24T19:11:14Z 32 Pages, 6 Figures, 2 Tables Light: Science & Applications (2026) Gyeo-Re Han Merve Eryilmaz Artem Goncharov Yuzhu Li Shun Ye Aoi Tomoeda Emily Ngo Margherita Scussat Xiao Wang Zixiang Ji Max Zhang Jeffrey J. Hsu Omai B. Garner Dino Di Carlo Aydogan Ozcan 10.1038/s41377-026-02275-9 http://arxiv.org/abs/2512.21335v1 Autonomous Uncertainty Quantification for Computational Point-of-care Sensors 2025-12-24T18:59:47Z Computational point-of-care (POC) sensors enable rapid, low-cost, and accessible diagnostics in emergency, remote and resource-limited areas that lack access to centralized medical facilities. These systems can utilize neural network-based algorithms to accurately infer a diagnosis from the signals generated by rapid diagnostic tests or sensors. However, neural network-based diagnostic models are subject to hallucinations and can produce erroneous predictions, posing a risk of misdiagnosis and inaccurate clinical decisions. To address this challenge, here we present an autonomous uncertainty quantification technique developed for POC diagnostics. As our testbed, we used a paper-based, computational vertical flow assay (xVFA) platform developed for rapid POC diagnosis of Lyme disease, the most prevalent tick-borne disease globally. The xVFA platform integrates a disposable paper-based assay, a handheld optical reader and a neural network-based inference algorithm, providing rapid and cost-effective Lyme disease diagnostics in under 20 min using only 20 uL of patient serum. By incorporating a Monte Carlo dropout (MCDO)-based uncertainty quantification approach into the diagnostics pipeline, we identified and excluded erroneous predictions with high uncertainty, significantly improving the sensitivity and reliability of the xVFA in an autonomous manner, without access to the ground truth diagnostic information of patients. Blinded testing using new patient samples demonstrated an increase in diagnostic sensitivity from 88.2% to 95.7%, indicating the effectiveness of MCDO-based uncertainty quantification in enhancing the robustness of neural network-driven computational POC sensing systems. 2025-12-24T18:59:47Z 18 Pages, 5 Figures ACS Nano (2026) Artem Goncharov Rajesh Ghosh Hyou-Arm Joung Dino Di Carlo Aydogan Ozcan 10.1021/acsnano.6c06616 http://arxiv.org/abs/2512.21180v1 Equivariant Multiscale Learned Invertible Reconstruction for Cone Beam CT: From Simulated to Real Data 2025-12-24T13:59:43Z Cone Beam CT (CBCT) is an important imaging modality nowadays, however lower image quality of CBCT compared to more conventional Computed Tomography (CT) remains a limiting factor in CBCT applications. Deep learning reconstruction methods are a promising alternative to classical analytical and iterative reconstruction methods, but applying such methods to CBCT is often difficult due to the lack of ground truth data, memory limitations and the need for fast inference at clinically-relevant resolutions. In this work we propose LIRE++, an end-to-end rotationally-equivariant multiscale learned invertible primal-dual scheme for fast and memory-efficient CBCT reconstruction. Memory optimizations and multiscale reconstruction allow for fast training and inference, while rotational equivariance improves parameter efficiency. LIRE++ was trained on simulated projection data from a fast quasi-Monte Carlo CBCT projection simulator that we developed as well. Evaluated on synthetic data, LIRE++ gave an average improvement of 1 dB in Peak Signal-to-Noise Ratio over alternative deep learning baselines. On real clinical data, LIRE++ improved the average Mean Absolute Error between the reconstruction and the corresponding planning CT by 10 Hounsfield Units with respect to current proprietary state-of-the-art hybrid deep-learning/iterative method. 2025-12-24T13:59:43Z 29 pages. arXiv admin note: substantial text overlap with arXiv:2401.11256 Nikita Moriakov Efstratios Gavves Jonathan H. Mason Carmen Seller-Oria Jonas Teuwen Jan-Jakob Sonke http://arxiv.org/abs/2512.21369v1 Structure, biomineralization and biodegradation of Ca-Mg oxyfluorosilicates synthesized by inorganic salt coprecipitation 2025-12-24T03:34:24Z In this research, a novel group of Ca-Mg oxyfluorosilicates containing different levels of fluoride substituting for oxide was synthesized by an inorganic salt coprecipitation process followed by calcination/sintering. The effects of the incorporation of fluoride on the resultant structural characteristics, apatite-forming ability and biodegradability were evaluated by X-ray diffraction, transmission electron microscopy, scanning electron microscopy/energy-dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, inductively coupled plasma spectroscopy and pH measurements. According to the results, the samples containing up to 2 mol% F present a single-phase structure of diopside (MgCaSi2O6) doped with F. It was also found that to meet the most biomineralization characteristic, the optimal value of fluoride in the homogeneous samples is 1 mol%. In this regard, on the one hand, the partial incorporation of fluoride into apatite (via forming fluorohydroxyapatite) and, on the other hand, the absence of fluorite (CaF2) as a consumer of Ca in the deposits are responsible for achieving the most apatite-forming ability circumstance controlled by an ion-exchange reaction mechanism. In conclusion, this study reflects the merit of the optimization of fluoride-doping into Ca-Mg silicates for development in biomedicine. 2025-12-24T03:34:24Z Ceramics International, 43 (2017) 10299-10306 E. Salahinejad M. Jafari Baghjeghaz 10.1016/j.ceramint.2017.05.059 http://arxiv.org/abs/2512.20859v1 Study of the Influence of Implant Material on Magnetocardiography Measurements Using SQUID Sensors 2025-12-24T00:35:19Z Magnetocardiography system is a medical device that diagnoses cardiac disease by measuring magnetic fields generated from electric currents flowing through the myocardium. However, the accuracy of measurement data can be degraded if strong magnetic materials are present or magnetic field changes occur near the MCG system. With the widespread use of implants, the number of patients with metallic implants is increasing, but there is a lack of in-depth research on the potential impact of implant materials on the results of the MCG examination. This study aims to analyze the effect of implant materials on MCG measurements and establish relevant criteria. In this study, a 96-channel MCG system employing Superconducting Quantum Interference Device sensors, specifically first-order gradiometers based on the Double Relaxation Oscillation SQUID method, and a Magnetically Shielded Room were utilized. Ti6Al4V ELI was selected as the representative implant material sample. Experiments were conducted under extreme conditions, where a sample significantly larger than an actual implant was placed as close as possible to the sensors. As a result, when the implant material was at the minimum distance to the sensor, the noise increase was approximately 0.7 fT/$\sqrt{\mathrm{Hz}}$, which satisfies the sensitivity criteria for MCG. Furthermore, since these results were obtained under severely adverse conditions designed to maximize the noise impact, it is anticipated that the effect would be even more negligible in actual clinical settings. In conclusion, it was confirmed that common implant materials have little to no effect on MCG measurements. However, as the experiments were not conducted with the material inserted into the human body, unlike actual clinical environments, the generation of magnetic fields due to micromotion has not been verified, thus requiring further experimentation. 2025-12-24T00:35:19Z 7 pages, 9 figures, 2 tables Journal of the Korean Physical Society (2026): 1-8 Ho-Seong Lee Jae-Hyun Ahn Yong-Hwan Kim 10.1007/s40042-026-01640-6 http://arxiv.org/abs/2508.01122v2 Fine-tuning physics-informed neural networks for cavity flows using coordinate transformation 2025-12-23T15:23:25Z Physics-informed neural networks (PINNs) have attracted attention as an alternative approach to solve partial differential equations using a deep neural network (DNN). Their simplicity and capability allow them to solve inverse problems for many applications. Despite the versatility of PINNs, it remains challenging to reduce their training cost. Using a DNN pre-trained with an arbitrary dataset with transfer learning or fine-tuning is a potential solution. However, a pre-trained model using a different geometry and flow condition than the target may not produce suitable results. This paper proposes a fine-tuning approach for PINNs with coordinate transformation, modelling lid-driven cavity flows with various shapes. We formulate the inverse problem, where the reference data inside the domain and wall boundary conditions are given. A pre-trained PINN model with an arbitrary Reynolds number and shape is used to initialize a target DNN. To reconcile the reference shape with different targets, governing equations as a loss of the PINNs are given with coordinate transformation using a deformation gradient tensor. Numerical examples for various cavity flows with square, rectangular, shear deformed and inflated geometries demonstrate that the proposed fine-tuning approach improves the training convergence compared with a randomly-initialized model. A pre-trained model with a similar geometry to the target further increases training efficiency. These findings are useful for real-world applications such as modelling intra-aneurysmal blood flows in clinical use. 2025-08-02T00:12:35Z 29 pages, 23 figures Ryuta Takao Satoshi Ii http://arxiv.org/abs/2509.14844v2 Non-Intrusive Parametrized-Background Data-Weak Reconstruction of Cardiac Displacement Fields from Sparse MRI-like Observations 2025-12-23T12:08:33Z Personalized cardiac diagnostics require accurate reconstruction of myocardial displacement fields from sparse clinical imaging data, yet current methods often demand intrusive access to computational models. In this work, we apply the non-intrusive Parametrized-Background Data-Weak (PBDW) approach to three-dimensional (3D) cardiac displacement field reconstruction from limited Magnetic Resonance Image (MRI)-like observations. Our implementation requires only solution snapshots -- no governing equations, assembly routines, or solver access -- enabling immediate deployment across commercial and research codes using different constitutive models. Additionally, we introduce two enhancements: an H-size minibatch worst-case Orthogonal Matching Pursuit (wOMP) algorithm that improves Sensor Selection (SS) computational efficiency while maintaining reconstruction accuracy, and memory optimization techniques exploiting block matrix structures in vectorial problems. We demonstrate the effectiveness of the method through validation on a 3D left ventricular model with simulated scar tissue. Starting with noise-free reconstruction, we systematically incorporate Gaussian noise and spatial sparsity mimicking realistic MRI acquisition protocols. Results show exceptional accuracy in noise-free conditions (relative L2 error of order O(1e-5)), robust performance with 10% noise (relative L2 error of order O(1e-2)), and effective reconstruction from sparse measurements (relative L2 error of order O(1e-2)). The online reconstruction achieves four-order-of-magnitude computational speed-up compared to full Finite Element (FE) simulations, with reconstruction times under one tenth of second for sparse scenarios, demonstrating significant potential for integration into clinical cardiac modeling workflows. 2025-09-18T11:10:24Z 42 pages, 12 figures, 6 tables Francesco C. Mantegazza Federica Caforio Christoph Augustin Matthias A. F. Gsell Gundolf Haase Elias Karabelas http://arxiv.org/abs/2509.11762v2 Very-low-field MRI scanners: from the ideal to the real permanent magnet array 2025-12-23T11:38:36Z Very-low-field MRIs are becoming increasingly popular due to their portability and adaptability to different environments. They are being successfully used for various clinical applications, leading to a paradigm shift in the way imaging care is typically performed. The development of low-cost MRI scanner prototypes began a few years ago, with some interesting and promising open-source projects emerging in both hardware and software design. Using permanent magnets (PMs) to generate the static magnetic field B0 can substantially reduce the manufacturing cost while achieving satisfactory homogeneity. This article aims to explore the reasons behind discrepancies between magnet design and prototype performance in terms of magnetic field homogeneity. Understanding the impact of the practical implementation of magnet design could inform the development of more tolerant designs in future, simplifying subsequent B0 shimming procedures or even making them unnecessary. This work also evidences the impact of using different numerical model approximations in the modelling phase, proving how they also impact the quality of the design outcomes. 2025-09-15T10:29:20Z 15 pages, 9 figures IEEE Transactions on Instrumentation and Measurement (2025) Vol. 74, Art. no. 4021514 Umberto Zanovello Alessandro Arduino Vittorio Basso Luca Zilberti Alessandro Sola Andrea Agosto Luca Toso Oriano Bottauscio 10.1109/TIM.2025.3638912 http://arxiv.org/abs/2512.20067v1 Microscopic and spectroscopic evidences for multiple ion-exchange reactions controlling biomineralization of CaO.MgO.2SiO2 nanoceramics 2025-12-23T05:36:18Z This study is focused on the mechanism of in vitro biomineralization on the surface of CaO.MgO.2SiO2 (diopside) nanostructured coatings by scanning electron microscopy, energy-dispersive X-ray spectroscopy and inductively coupled plasma spectroscopy assessments. A homogeneous diopside coating of almost 2 um in thickness was deposited on a medical-grade stainless steel by coprecipitation, dipping and sintering sequences. After soaking the sample in a simulated body fluid (SBF) for 14 days, a layer with the thickness of 8 μm is recognized to be substituted for the primary diopside deposit, suggesting the mineralization of apatite on the surface. Investigations revealed that the newly-formed layer is predominantly composed of Ca, P and Si, albeit with a biased accumulations of P and Si towards the surface and substrate, respectively. The variations in the ionic composition and pH of the SBF due to the incubation of the sample were also correlated with the above-interpreted biomineralization. In conclusion, the multiple ion-exchange reactions related to Ca, Mg, Si and P were found to be responsible for the in vitro bioactivity of nanodiopside. 2025-12-23T05:36:18Z Ceramics International, 43 (2017) 8502-8508 R. Vahedifard E. Salahinejad 10.1016/j.ceramint.2017.04.001