https://arxiv.org/api/bRO/u+xv5CTrwxx4hjLOkaQpoJ42026-06-22T20:31:00Z898555515http://arxiv.org/abs/2512.24786v1A Dual-Tuned Concentric Multimodal RF Coil for 7T 1H/31P MRSI: Concurrently Enhancing B1 Efficiency Over Single-Tuned References2025-12-31T11:15:45ZThis study presents the design, simulation, and experimental validation of a dual-tuned concentric multimodal surface coil for 7T 1H/31P magnetic resonance spectroscopic imaging (MRSI), developed to significantly enhance 31P B1 efficiency while improving 1H performance. The coil architecture utilizes two interleaved sets of three concentric loop resonators. Intra-nucleus electromagnetic coupling within each three-loop set generates a spectrum of eigenmodes; the operational modes for 1H and 31P were specifically selected because their co-directed current distributions reinforce the magnetic field at the center, yielding B1 patterns that resemble those of conventional single-loop surface coils but with superior efficiency. Full-wave electromagnetic simulations and bench measurements on a fabricated prototype were conducted to characterize the multimodal resonance behavior, scattering parameters, B1 distribution, and 10-g local SAR, using size-matched conventional single-tuned loops as references. The results confirmed that the design reproducibly generated the predicted eigenmode ordering with sufficient spectral separation to prevent interference from parasitic or undesired modes. Notably, the multimodal design achieved an 83% boost in 31P B1 efficiency and a 21% boost in 1H B1 efficiency at the coil center compared to same-sized single-tuned references. Sufficient inter-nuclear decoupling was achieved to prevent signal leakage between channels, and simulations with a human head model confirmed that the peak 10-g local SAR remained comparable to conventional designs. These findings demonstrate that this multimodal concentric design offers a robust and highly efficient solution for multinuclear MRSI at ultrahigh fields, effectively mitigating the sensitivity limitations of X-nuclei without compromising proton-based imaging capabilities.2025-12-31T11:15:45Z21 pages, 10 figuresYunkun ZhaoXiaoliang Zhanghttp://arxiv.org/abs/2512.24529v1Towards Interpretable AI in Personalized Medicine: A Radiological-Biological Radiomics Dictionary Connecting Semantic Lung-RADS and imaging Radiomics Features; Dictionary LC 1.02025-12-31T00:23:39ZLung cancer remains the leading cause of cancer-related mortality worldwide, with survival strongly dependent on early detection. Standard-dose computed tomography (CT) screening using the Lung Imaging Reporting and Data System (Lung-RADS) standardizes pulmonary nodule assessment but is limited by inter-reader variability and reliance on qualitative descriptors, while radiomics offers quantitative biomarkers that often lack clinical interpretability. To bridge this gap, we propose a radiological-biological dictionary that aligns radiomic features (RFs) with Lung-RADS semantic categories. A clinically informed dictionary translating ten Lung-RADS descriptors into radiomic proxies was developed through literature curation and validated by eight expert reviewers. As a proof of concept, imaging and clinical data from 977 patients across 12 collections in The Cancer Imaging Archive (TCIA) were analyzed; following preprocessing and manual segmentation, 110 RFs per nodule were extracted using PyRadiomics in compliance with the Image Biomarker Standardization Initiative (IBSI). A semi-supervised learning framework incorporating 499 labeled and 478 unlabeled cases was applied to improve generalizability, evaluating seven feature selection methods and ten interpretable classifiers. The optimal pipeline (ANOVA feature selection with a support vector machine) achieved a mean validation accuracy of 0.79. SHapley Additive exPlanations (SHAP) analysis identified key RFs corresponding to Lung-RADS semantics such as attenuation, margin irregularity, and spiculation, supporting the validity of the proposed mapping. Overall, this dictionary provides an interpretable framework linking radiomics and Lung-RADS semantics, advancing explainable artificial intelligence for CT-based lung cancer screening.2025-12-31T00:23:39Z13 Pages, 2 Tables and 3 FiguresAli Fathi JouzdaniShahram TaebMehdi MaghsudiArman GorjiArman RahmimMohammad R. Salmanpourhttp://arxiv.org/abs/2512.24489v1High Space-bandwidth Product Label-free Examination of iPSC-derived Brain Organoids via Fourier Ptychographic Microscopy2025-12-30T22:17:44ZFourier ptychographic microscopy (FPM) is a promising quantitative phase imaging technique that enables high-resolution, label-free imaging over a large field-of-view. Here, we present the first application of FPM for the quantitative analysis of human brain organoid slices, providing a powerful, cost-effective, and label-free enhancement to the current gold-standard fluorescence microscopy. Brain organoids, prepared as thin (5 micrometer) slices, were imaged with a custom-built FPM system consisting of a standard light microscope (4x, 0.2 NA objective) and a 7x7 LED array. This configuration achieved a synthetic numerical aperture of 0.54 and a spatial resolution of approximately 488 nm across an area of 2.077 x 3.65 mm. Fluorescence microscopy was used in parallel for neurons, astrocytes, and nuclei labeling, providing rich fluorescence imaging. Moreover, we designed an automated method to merge classical resolution fluorescence images to visualize the whole brain organoid and align it with the numerically increased space-bandwidth product FPM image. The provided alignment method enables rich phase-fluorescence correlative imaging. Based on the segmentation performed on the stitched fluorescence images, we devised a quantitative phase analysis revealing a higher mean optical thickness of the nuclei versus astrocytes and neurons. Notably, nuclei located in neurogenic regions consistently exhibited significantly higher phase values (optical path difference) compared to nuclei elsewhere, suggesting cell-type-specific biophysical signatures. The label-free, quantitative, and high-throughput capabilities of the FPM approach demonstrated here make it a powerful and accessible tool for future structural and functional studies of whole-section brain organoid development and disease modeling studies.2025-12-30T22:17:44Z14 pages, 6 figuresMikolaj KrysaMikolaj RogalskiPiotr ArcabPawel GoclowskiKamil KalinowskiPiotr ZdańkowskiVishesh K. DubeyMukesh VarshneyBalpreet S. AhluwaliaMaciej Trusiak10.1109/JSTQE.2025.3650095http://arxiv.org/abs/2512.24401v1Finite element analysis of very large bone models based on micro-CT scans2025-12-30T18:35:56ZHigh-resolution voxel-based micro-finite element ($μ$FE) models derived from $μ$CT imaging enable detailed investigation of bone mechanics but remain computationally challenging at anatomically relevant scales. This study presents a comprehensive $μ$FE framework for large-scale biomechanical analysis of an intact New Zealand White (NZW) rabbit femur, integrating advanced segmentation, scalable finite element solvers, and experimental validation using predominantly open-source libraries. Bone geometries were segmented from $μ$CT data using the MIA clustering algorithm and converted into voxel-based $μ$FE meshes, which were solved using the open-source MFEM library with algorithms designed for large-scale linear elasticity systems.
The numerical solutions were verified by comparing with a commercial finite element solver, and by evaluating the performance of full assembly and element-by-element formulations within MFEM. Models containing over $8\times10^{8}$ DOFs were solved using moderate HPC resources, demonstrating the feasibility of anatomically realistic $μ$FE simulations at this scale. Resolution effects were investigated by comparing models with voxel sizes of 20, 40, and 80 $μ$m, revealing that 40 $μ$m preserves boundary displacement and principal strain distributions with minimal bias while significantly reducing computational cost. Sensitivity analyses further showed that segmentation parameters influence the global mechanical response.
Finally, $μ$FE predictions were coupled with Digital Image Correlation measurements on an NZW rabbit femur under compression to calibrate effective bone material properties at the micron scale. The results demonstrate that large-scale, experimentally informed $μ$FE modeling can be achieved using open-source tools, providing a robust foundation for preclinical assessment of bone mechanics and treatment-related risks.2025-12-30T18:35:56Z23 pages, 21 figuresShani Martinez-WeissbergWill PaznerZohar Yosibashhttp://arxiv.org/abs/2512.24397v1Analytical phase kurtosis of the constant gradient spin echo2025-12-30T18:32:27ZThe Gaussian phase approximation (GPA) underlies many standard diffusion magnetic resonance (MR) signal models, yet its validity is rarely scrutinized. Here, we assess the validity of the GPA by analytically deriving the excess phase kurtosis $κ_4/κ_2^2$, where $κ_n$ is the $n^{\text{th}}$ cumulant of the accumulated phase distribution due to motion. We consider the signal behavior of the spin echo with constant gradient amplitude $g$ and echo time $T$ in several one-dimensional model systems: (1) a stationary Poisson pore-hopping model with uniform pore spacing $Δx$ and mean inter-hop time $τ_{\text{hop}}$; (2) a trapped-release model in which spin isochromats are initially immobilized and then released with diffusivity $D$ following an exponentially-distributed release time, $τ_{\text{rel}}$; and (3) restricted diffusion in a domain of length $L$. To our knowledge, this is among the first systematic analytical treatments of spin echo phase kurtosis without assuming Gaussian compartments or infinitesimally short gradient pulses. In the pore-hopping system, $κ_4/κ^2_2 = (9/5)τ_{\text{hop}}/T$, inversely proportional to the mean hop number, $T/τ_{\text{hop}}$. In the trapped-release system, $κ_4/κ_2^2$ is positive and decreases roughly log-linearly with $T/\langleτ_{\text{rel}}\rangle$, where $\langleτ_{\text{rel}}\rangle$ is the average release time. For restriction, $κ_4/κ_2^2$ vanishes at small and large $L/\sqrt{DT}$, but has complicated intermediate behavior. There is a negative peak at $L/\sqrt{DT}\approx 1.2$ and a positive peak at $L/\sqrt{DT}\approx 4.4$. Monte Carlo simulations are included to validate the analytical findings. Overall, we find that the GPA does not generally hold for these systems under moderate experimental conditions, i.e., $T=10\;\mathrm{ms}$, $g\approx 0.2-0.6\;\mathrm{T/m}$.2025-12-30T18:32:27Z17 pages, 6 figuresTeddy X CaiNathan H WilliamsonPeter J Basserhttp://arxiv.org/abs/2512.24322v1Iterative projected gradient descent for dynamic PET kernel reconstruction2025-12-30T16:21:23ZDynamic positron emission tomography (PET) reconstruction often presents high noise due to the use of short duration frames to describe the kinetics of the radiotracer. Here we introduce a new method to calculate a kernel matrix to be used in the kernel reconstruction for noise reduction in dynamic PET. We first show that the kernel matrix originally calculated using a U-net neural network (DeepKernel) can be calculated more efficiently using projected gradient descent (PGDK), with several orders of magnitude faster calculation time for 3D images. Then, using the PGDK formulation, we developed an iterative method (itePGDK) to calculate the kernel matrix without the need of high quality composite priors, instead using the noisy dynamic PET image for calculation of the kernel matrix. In itePGDK, both the kernel matrix and the high quality reference image are iteratively calculated using PGDK. We performed 2D simulations and real 3D mouse whole body scans to compare itePGDK with DeepKernel and PGDK. Brain parametric maps of cerebral blood flow and non-displaceable binding potential were also calculated in 3D images. Performance in terms of bias-variance tradeoff, mean squared error, and parametric maps standard error, was similar between PGDK and DeepKernel, while itePGDK outperformed these methods in these metrics. Particularly in short duration frames, itePGDK presents less bias and less artifacts in fast kinetics organs uptake compared with DeepKernel. itePGDK eliminates the need to define composite frames in the kernel method, producing images and parametric maps with improved quality compared with deep learning methods.2025-12-30T16:21:23ZAlan MirandaSteven Staelenshttp://arxiv.org/abs/2601.06080v1Fluoride doping into SiO2-MgO-CaO bioactive glass nanoparticles: bioactivity, biodegradation and biocompatibility assessments2025-12-30T01:52:50ZIn this research, for the first time, the structure, bioactivity, biodegradation and biocompatibility of SiO2-MgO-CaO glasses doped with different levels of fluoride were studied. The glassy powder samples were synthesized by a coprecipitation method followed by calcination at 500 C, where amorphicity and fluoride incorporation were verified by X-ray diffraction and Raman spectroscopy, respectively. The in vitro biomineralization and biodegradation of the samples were also investigated by electron microscopy, Raman spectroscopy and inductively coupled plasma optical emission spectrometry. These assessments revealed that there is an optimum level of fluoride doping to meet the highest bioactivity. Remarkably, the same level of incorporation presented the foremost biocompatibility with respect to osteoblast-like MG-63 human cells, as realized by the MTT assay and cell attachment studies.2025-12-30T01:52:50ZCeramics International, 44 (2018) 17506-17513N. EsmatiT. KhodaeiE. SalahinejadE. Sharifi10.1016/j.ceramint.2018.06.222http://arxiv.org/abs/2512.23555v1Physical Limits of Proximal Tumor Detection via MAGE-A Extracellular Vesicles2025-12-29T15:50:53ZEarly cancer detection relies on invasive tissue biopsies or liquid biopsies limited by biomarker dilution. In contrast, tumour-derived extracellular vesicles (EVs) carrying biomarkers like melanoma-associated antigen-A (MAGE-A) are highly concentrated in the peri-tumoral interstitial space, offering a promising near-field target. However, at micrometre scales, EV transport is governed by stochastic diffusion in a low copy number regime, increasing the risk of false negatives. We theoretically assess the feasibility of a smart-needle sensor detecting MAGE-A-positive microvesicles near a tumour. We use a hybrid framework combining particle-based Brownian dynamics (Smoldyn) to quantify stochastic arrival and false negative probabilities, and a reaction-diffusion PDE for mean concentration profiles. Formulating detection as a threshold-based binary hypothesis test, we find a maximum feasible detection radius of approximately 275 micrometers for a 6000 s sensing window. These results outline the physical limits of proximal EV-based detection and inform the design of minimally invasive peri-tumoral sensors.2025-12-29T15:50:53ZA. Sila OkcuM. Etem BasOzgur B. Akanhttp://arxiv.org/abs/2512.23513v1Incorporating Tissue Composition Information in Total-Body PET Metabolic Quantification of Bone Marrow through Dual-Energy CT2025-12-29T14:50:12ZBone marrow (BM) metabolic quantification with 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is of broad clinical significance for accurate assessment of BM at staging and follow-up, especially when immunotherapy is involved. However, current methods of quantifying BM may be inaccurate because the volume defined to measure bone marrow may also consist of a fraction of trabecular bone in which 18F-FDG activity is negligible, resulting in a potential underestimation of true BM uptake. In this study, we demonstrate this bone-led tissue composition effect and propose a bone fraction correction (BFC) method using X-ray dual-energy computed tomography (DECT) material decomposition. This study included ten scans from five cancer patients who underwent baseline and follow-up dynamic 18F-FDG PET and DECT scans using the uEXPLORER total-body PET/CT system. The voxel-wise bone volume fraction was estimated from DECT and then incorporated into the PET measurement formulas for BFC. The standardized uptake value (SUV), 18F-FDG delivery rate K1, and net influx rate Ki values in BM regions were estimated with and without BFC and compared using the statistical analysis. The results first demonstrated the feasibility of performing voxel-wise material decomposition using DECT for metabolic BM imaging. With BFC, the SUV, K1, and Ki values significantly increased by an average of 13.28% in BM regions compared to those without BFC (all P<0.0001), indicating the impact of BFC for BM quantification. Parametric imaging with BFC further confirmed regional analysis. Our study using DECT suggests current SUV and kinetic quantification of BM are likely underestimated in PET due to the presence of a significant bone volume fraction. Incorporating tissue composition information through BFC may improve BM metabolic quantification.2025-12-29T14:50:12ZSiqi LiBenjamin A. SpencerYiran WangYasser G. AbdelhafezHeather HuntJ. Anthony SeibertSimon R. CherryRamsey D. BadawiLorenzo NardoGuobao Wanghttp://arxiv.org/abs/2505.03632v3The role of friction forces in arterial mechanical thrombectomy: a review2025-12-29T11:01:19ZMultiple clinical trials have demonstrated the superiority of mechanical thrombectomy (MT) in treating acute ischemic stroke (AIS). Stent retriever (SR) and aspiration techniques are the standard methods for removing occluded emboli, with evolving technologies improving MT efficiency. However, procedural success remains uncertain. Frictional forces, specifically clot-vessel, clot-SR, and SR-vessel interactions, play a critical role in MT outcomes. This review examines frictional forces during MT and their impact on success, analyzing publications from 2015 to 2025. We focus on studies that calculated friction or retrieval forces using in vitro models. We have also included current trends, limitations, and future perspectives on studying and understanding frictional forces and their implementation into in silico models. Findings indicate that fibrin-rich clots are more difficult to retrieve than red blood cell (RBC)-rich clots due to their higher friction coefficient, three to four times greater, an observation supported by multiple studies. SR-vessel and SR-clot friction also influence MT effectiveness. SR-vessel interaction plays a crucial role in acutely curved vessels, as SR compression reduces its efficiency. In SR-clot interaction, RBC-rich clot fragmentation is linked to relative interaction forces. In summary, obtaining in vivo frictional values remains challenging, and inconsistencies persist in past in vitro studies. Further, a deeper understanding of frictional forces is essential for optimizing MT, improving current SRs, and developing next-generation thrombectomy technologies.2025-05-06T15:31:09ZJournal of Biomechanics 192 (2025) 112966Mahesh S. NagargojeVirginia FregonaGiulia LuraghiFrancesco MigliavaccaGuglielmo PeroJose Felix Rodriguez Matas10.1016/j.jbiomech.2025.112966http://arxiv.org/abs/2512.23151v1Two-stage Respiratory Motion-resolved Radial MR Image Reconstruction Using an Interpretable Deep Unrolled Network2025-12-29T02:29:13ZDue to the prolonged MRI encoding process, respiratory motion can cause undesired artifacts and image blurring, degrading image quality and limiting clinical applications in abdominal and pulmonary imaging. In this work, we develop a two-stage respiratory motion-resolved radial MR image reconstruction pipeline using an interpretable deep unrolled network (MoraNet), enabling high-quality imaging under free-breathing conditions. Firstly, low-resolution images are reconstructed from the central region of successive golden-angle radial k-space to extract respiratory motion signals. The binned k-space data based on the respiratory signal are then used to reconstruct the motion-resolved high-resolution image for each motion state. The MoraNet applies nonuniform fast Fourier transform (NUFFT) to operate radial encoding and convolutional neural network (CNN) modules to conduct image regularizations. The MoraNet was trained on retrospectively acquired lung MRI images for both fully sampled and undersampled acquisitions. The performance of the proposed method was evaluated on digital CT/MRI breathing XCAT (CoMBAT) phantom data, QUASAR motion phantom data acquired from a 1.0T MRI scanner and volunteer chest data acquired from a 1.5T MRI scanner. The MoraNet pipeline was compared with motion-averaged reconstruction and a conventional compressed sensing (CS)-based method in terms of SSIM, RMSE and computation time. Simulation and experimental results demonstrated that the proposed network could provide accurate respiratory signal estimation and enable effective motion correction. Compared with the CS method, the MoraNet preserved better structural details with lower RMSE and higher SSIM values at acceleration factor of 4, and meanwhile took ten-fold faster inference time.2025-12-29T02:29:13ZShanshan ShanHongli ChenYuhan WeiPeng WuYang GaoTess ReynoldsPaul LiuJialiang ZhangQidi LuoChunyi LiuPaul KeallFeng LiuYaqin ZhangDavid E. J. WaddingtonMingyuan Gaohttp://arxiv.org/abs/2601.00027v1Zero-Dimensional Cardiovascular Modeling: A Personalized Approach to Non-Invasive Measurement and Sensitivity Analysis2025-12-28T22:22:47ZZero-dimensional cardiovascular models provide a computationally efficient framework for studying global hemodynamic behavior, yet the influence of model complexity on parameter sensitivity remains insufficiently understood. This work investigates two lumped-parameter cardiovascular models, a simplified single-ventricle configuration and a detailed four-chamber representation, to examine how physiological parameter sensitivities vary with model structure. Time-varying elastance functions are used to represent cardiac dynamics, and global sensitivity analysis is performed using Sobol and Morris methods to quantify the impact of key physiological parameters, including venous return, myocardial contractility, total peripheral resistance, and arterial compliance. The results demonstrate that sensitivity rankings differ substantially between the two models, highlighting the role of model granularity and parameter interactions in shaping cardiovascular responses. These findings support sensitivity-driven model reduction and provide a foundation for scalable, non-invasive cardiovascular simulation frameworks.2025-12-28T22:22:47Z30 pages, multiple figures. Zero-dimensional cardiovascular modeling with global sensitivity analysis using Sobol and Morris methodsPranav Kumar Sasikumarhttp://arxiv.org/abs/2601.05275v1On the dynamical stability of skeletal muscle2025-12-28T22:22:06ZThere has been debate for over 70-years about whether active skeletal muscle is dynamically stable at lengths greater than its optimal length. The stability of computational muscle models is a critical issue, as it directly affects our ability to simulate muscle deformation across different operating lengths, especially at lengths where muscles are known to remain functional despite model-predicted instabilities.
In this study, we revisit the question of dynamical stability of ODE-based models of skeletal muscle. In particular, we investigate whether activation-independent tissue properties can provide stability to contractions along the dip region of the total force-length curve. First, using a combination of analytical tools (eigenvalue analysis and non-dimensionalization) and numerical simulations, we confirm that traditional Hill-type muscle models can display divergent dynamics in this region. Then, we propose a stabilized version of a 1D Hill-type muscle model that incorporates the 3D nature of skeletal muscle deformation. This results in a completely convex force-length relationship that can bring robustness to numerical simulations, while preserving the computational efficiency of 1D models. Our findings suggest that activation-independent intrinsic mechanical properties of muscle are sufficient to stabilize contractions even in the dip region, offering new insight into how muscles maintain functional integrity during active stretch.2025-12-28T22:22:06ZJavier A. AlmonacidNilima NigamJames M. Wakelinghttp://arxiv.org/abs/2503.00587v5Dual-Input Dynamic Convolution for Positron Range Correction in PET Image Reconstruction2025-12-28T21:03:20ZPositron range (PR) blurring degrades positron emission tomography (PET) image resolution, particularly for high-energy emitters like gallium-68 (68 Ga). We introduce Dual-Input Dynamic Convolution (DDConv), a novel computationally efficient approach trained with voxel-specific PR point spread functions (PSFs) from Monte Carlo (MC) simulations and designed to be utilized within an iterative reconstruction algorithm to perform PR correction (PRC). By dynamically inferring local blurring kernels through a trained convolutional neural network (CNN), DDConv captures complex tissue interfaces more accurately than prior methods. Additionally, it also computes the transpose operator, ensuring consistency within iterative PET reconstruction. Comparisons with a state-of-the-art, tissue-dependent correction confirm the advantages of DDConv in recovering higher-resolution details in heterogeneous regions, including bone-soft tissue and lung-soft tissue boundaries. Experiments across digital phantoms and MC-simulated data show that DDConv offers near-MC accuracy and outperforms the state-of-the-art technique, namely spatially-variant and tissue-dependent (SVTD), especially in areas with complex material interfaces. Results from real phantom experiments further confirm DD-Conv's robustness and practical applicability: while both DD-Conv and SVTD performed similarly in homogeneous soft-tissue regions, DDConv provided more accurate activity recovery and sharper delineation at heterogeneous lung-soft tissue interfaces. Our code available at https://github.com/mellak/ddconv-prc.2025-03-01T18:52:23Z11 pages, 10 figures, 2 tablesYouness MellakAlexandre BousseThibaut MerlinÉlise ÉmondMikko HakulinenDimitris Visvikis10.1109/TRPMS.2025.3647264http://arxiv.org/abs/2512.22952v1Modular Metamaterials for Adaptable MRI Signal Control: Combining Dipole Arrays with Hexagon-based Artificial Dielectrics2025-12-28T14:50:42ZEmerging concepts of metamaterials for MRI offer improved image quality through enhanced RF field control. However, current designs are often limited by bulky configurations, dielectric losses, and limited adaptability. Patient-specific optimization - essential for improving field homogeneity, boosting local SNR, and addressing anatomical variability - requires redesigning each setup. To overcome these limitations, we introduce a hexagonally-packed artificial dielectric, free of any lumped-elements, capable of achieving a wide range of high relative permittivities (30-1400) suitable for clinical and ultra-high-field MRI. We identify multilayered and in-plane-shifted hexagonal configurations that support compact, modular layouts. Furthermore, we combine these artificial dielectrics with dipole arrays to create a modular system for adaptable signal enhancement, tuned via electric and magnetic dipole modes by adjusting the length of conductive strips. In-vivo 7T MRI results demonstrate enhanced field control and high-resolution imaging. This lightweight, flexible, and modular platform enables patient-specific RF field shaping, thus opening up new avenues for personalized and adaptable MRI technology.2025-12-28T14:50:42ZSantosh Kumar MauryaIlan GoldbergRita Schmidt