https://arxiv.org/api/z4OMoo/fpvnnDyC99ClSm5Lstwc2026-06-22T19:21:43Z898554015http://arxiv.org/abs/2601.01667v1An Ingestible Light Source for Deep Photoacoustic Imaging2026-01-04T21:00:05ZPhotoacoustic tomography leverages ultrasound's deep tissue penetration to retrieve optical absorption contrast well beyond the optical diffusion limit. Conventional photoacoustic systems rely on externally delivered light and are therefore constrained by optical attenuation, limiting imaging depths to several centimeters. Here, we overcome this constraint using a compact, acoustically powered device that provides optical excitation directly from within the target medium. By exploiting the weak attenuation of low-MHz ultrasound, acoustic energy is transmitted through tissue to wirelessly power a pulsed laser diode. The emitted light pulses generate photoacoustic signals that encode local optical absorption at clinically relevant depths, which could enable imaging in regions such as the gastrointestinal tract that are inaccessible to surface-based illumination. We demonstrate this approach by imaging through a 12 cm thick phantom, establishing a pathway toward deep-tissue photoacoustic imaging.2026-01-04T21:00:05ZDavid C. GarrettLihong V. Wanghttp://arxiv.org/abs/2510.17283v3Optimized Single-Core PCF-Based SPR Biosensor for High-Performance Early-Stage Multi-Cancer Detection2026-01-04T19:31:37ZIn this study, we present a highly sensitive Surface Plasmon Resonance (SPR)-based biosensor integrated with a circular-lattice Photonic Crystal Fiber (PCF) for early-stage cancer detection. The proposed sensor leverages the synergy between SPR and PCF technologies to overcome the bulkiness and limited sensitivity of traditional SPR systems. A thin gold (Au) layer, responsible for plasmon excitation, is deposited on the fiber structure, while a nanolayer of vanadium pentoxide (V2O5) is introduced to enhance adhesion between the gold and the silica background, improving structural stability and field confinement. The sensor is designed to detect refractive index (RI) variations in biological analytes, specifically targeting cancerous cells from skin, blood, and adrenal gland tissues. The optical characteristics and performance of the sensor were thoroughly analyzed using the Finite Element Method (FEM) in COMSOL Multiphysics 6.1, allowing for precise simulation and optimization. The sensor demonstrates high sensitivity within the RI range of 1.360-1.395, corresponding to the RI values of the target cancer cells. Remarkable wavelength sensitivities of 21,250 nm/RIU, 53,571 nm/RIU, and 103,571 nm/RIU were achieved for skin, blood, and adrenal gland cancers, respectively. In addition, a maximum figure of merit (FOM) of 306.424 RIU^-1 and a spectral resolution (SR) of 9.57x10^-7 RIU further affirm the sensor's exceptional detection capabilities. These findings indicate the proposed SPR-PCF sensor's strong potential for real-time, label-free biosensing applications, particularly in precise and early cancer diagnostics.2025-10-20T08:16:43ZTonmoy MalakarMiss Nourin Nurain AminaZarin Tasnim NijhumNazmus Shakib Lalinhttp://arxiv.org/abs/2310.16055v3A nonconservative kinetic model under the action of an external force field for modeling the medical treatment of autoimmune response2026-01-03T11:56:04ZIn this paper, we develop a nonconservative kinetic framework to be applied to the study of immune system dysregulation. From the modeling viewpoint, the model regards a system composed of stochastically interacting agents, under the action of an eternal force field. According to the application perspectives of this paper, the external force field has a specific analytical shape. In this case, some analytical results are proved, i.e. existence, uniqueness, positivity, and boundedness of solution of the related Cauchy problem, at least locally in time. Then, the model is refined to be implemented for the study of treatment strategies in case of autoimmune response. Specifically, we distinguish the autonomous case from the nonautonomous one, representing the absence or delivery of drugs, respectively. The former allows us to gain some stability results. Whereas, the latter is qualitatively studied. Numerical simulations are provided for both schemes.2023-10-13T08:58:27ZCommunications in Nonlinear Science and Numerical Simulation 137 (2024): 108126Marco MenaleRomina Travaglini10.1016/j.cnsns.2024.108126http://arxiv.org/abs/2601.00997v1AI-Assisted Hyperspectral Interferometry and Single-Cell Dispersion Imaging2026-01-02T22:39:55ZInterferometry techniques are essential for extracting phase information from optical systems, enabling precise measurements of dispersion and highly sensitive detection of perturbations. While phase sensing offers enhanced sensitivity compared to conventional spectroscopy methods, this sensitivity often makes systems more vulnerable to external factors such as vibrations, introducing instability and noise. In this work, we demonstrate a broadband and AI-enhanced interferometry method, denoted general polarization common-path interferometry (GPCPI), that relaxes the polarization constraints of traditional common-path interferometry. The polarization decoupling feature enables simultaneous amplitude and phase measurements supplemented with deep neural autoencoders to detect phase anomalies in the spectrum through the analysis of second order derivative mapping of the phase profile, enhancing the accuracy of broadband phase measurements. The approach enables an order of magnitude improvement in phase stability compared to state-of-the-art interferometry techniques, leading to higher accuracy in phase sensing. Plasmonic metasurface phase sensing and hyperspectral single-cell dispersion imaging demonstrate the capability and sensitivity of the method over conventional spectroscopy. Our own adopted version of deep learning model, ConvNeXt V2, enables single-shot and real-time tracking of phase variation with minimized noise. Interference fringes over the cell cultured samples reveal the fingerprints of the normal (CCD-32Sk) vs cancerous (COLO-829) skin cells, enabling robust cell classification and disease diagnosis at single-cell level. The proposed interferometry technique offers a reliable, compact, and stable solution for broadband phase measurements and single-cell dispersion imaging for applications in metrology, molecular diagnostics, drug discovery, and quantum sensing.2026-01-02T22:39:55ZKamyar BehrouziTanveer Ahmed SiddiqueMegan TengWalid RedjemLiwei LinBoubacar Kantehttp://arxiv.org/abs/2507.09765v2CRYSP: a Total-Body PET based on cryogenic cesium iodide crystals2026-01-02T22:03:26ZTotal Body PET (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. We investigate the performance of pure CsI crystals operated at cryogenic temperatures ($\sim$100 K), where they achieve a light yield of approximately $10^5$ photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.2025-07-13T19:48:31Z20 pages, 12 figuresPhys. Med. Biol. 71 025001 (2026)S. R. SoletiP. DietzR. EsteveJ. Garcìa-BarrenaV. HerreroF. LopezF. MonrabalL. Navarro-CozcolluelaE. OblakJ. PelegrìnJ. RennerJ. ToledoS. TorelliJ. J. Gòmez-Cadenas10.1088/1361-6560/ae35c8http://arxiv.org/abs/2512.22026v2Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan2026-01-02T17:39:26ZIn this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner. We validate the accuracy of stopping power ratio (SPR) calculations using a conventional stoichiometric calibration approach and a prototype software, TissueXplorer. A validated CT simulator (DukeSim) was used to generate photon-counting CT projections of a computational head model, which were reconstructed with an open-source toolbox (ASTRA). The dose of 2 Gy was delivered through protons in a single fraction to target two different cases of nasal and brain tumors with a single lateral beam angle. Ground truth treatment plan was made directly on the computational head model using clinical treatment planning software (RayStation). This plan was then recalculated on the corresponding CT images for which SPR values were estimated using both the conventional method and the prototype software TissueXplorer. The mean percentage difference in estimating the stopping power ratio with TissueXplorer in all head tissues inside the scanned volume was 0.28%. Stopping power ratios obtained with this method showed smaller dose distribution differences from the ground truth plan than the conventional stoichiometric calibration method on the computational head model. Virtual imaging offers an alternative approach to validation of the SPR prediction from CT imaging, as well as its effect on the dose distribution and thus downstream clinical outcomes. According to this simulation study, software solutions that utilize spectral information, such as TissueXplorer, hold promise for more accurate prediction of the stopping power ratio than the conventional stoichiometric approach.2025-12-26T13:14:47Z16 pages, 5 figures; v2 Corrected spelling of an author nameS. VrbaškiG. StanićS. MolinelliM. BhattaraiE. AbadiM. CioccaE. Sameihttp://arxiv.org/abs/2601.06099v1Co-doping of silicate bioceramics as a potential strategy to further enhance mono-doping consequences2026-01-02T15:19:03ZSilicate bioceramics have attracted significant attention in medical applications, particularly in hard tissue regeneration, because of their controllable chemical, physical, and biological functionalities, while ensuring biocompatibility. The coordination of silicate bioceramics with mono-dopants has been extensively studied to enhance their osteogenesis, angiogenesis, and antibacterial activity. However, the concept of employing dual or multiple co-doping to further enhance these biomaterials still demands more attention. This review paper originally focuses on the effect of chemical interactions among co-dopants and the principal constituents of the silicates, on the bio-behavior of these bioceramics. Additionally, future prospects of co-doped silicate bioceramics are outlined, including in vivo studies, clinical trials, and potential commercialization.2026-01-02T15:19:03ZCoordination Chemistry Reviews, 514 (2024) 215963Sohrab MofakhamiErfan Salahinejad10.1016/j.ccr.2024.215963http://arxiv.org/abs/2601.00685v1Human-like AI-based Auto-Field-in-Field Whole-Brain Radiotherapy Treatment Planning With Conversation Large Language Model Feedback2026-01-02T13:23:12ZWhole-brain radiotherapy (WBRT) is a common treatment due to its simplicity and effectiveness. While automated Field-in-Field (Auto-FiF) functions assist WBRT planning in modern treatment planning systems, it still requires manual approaches for optimal plan generation including patient-specific hyperparameters definition and plan refinement based on quality feedback. This study introduces an automated WBRT planning pipeline that integrates a deep learning (DL) Hyperparameter Prediction model for patient-specific parameter generation and a large-language model (LLM)-based conversational interface for interactive plan refinement. The Hyperparameter Prediction module was trained on 55 WBRT cases using geometric features of clinical target volume (CTV) and organs at risk (OARs) to determine optimal Auto-FiF settings in RayStation treatment planning system. Plans were generated under predicted hyperparameters. For cases in which the generated plan was suboptimal, quality feedback via voice input was captured by a Conversation module, transcribed using Whisper, and interpreted by GPT-4o to adjust planning settings. Plan quality was evaluated in 15 independent cases using clinical metrics and expert review, and model explainability was supported through analysis of feature importance. Fourteen of 15 DL-generated plans were clinically acceptable. Normalized to identical CTV D95% as the clinical plans, the DL-generated and clinical plans showed no statistically significant differences in doses to the eyes, lenses, or CTV dose metrics D1% and D99%. The DL-based planning required under 1 minute of computation and achieved total workflow execution in approximately 7 minutes with a single mouse click, compared to 15 minutes for manual planning. In cases requiring adjustment, the Conversational module successfully improved dose conformity and hotspot reduction.2026-01-02T13:23:12Z22 pages, 7 figuresAdnan JafarAn QinGavin AtkinsXiaoyu HuYin GaoXun Jiahttp://arxiv.org/abs/2601.00937v1Biomechanics of Tori body motion during competition Sutemi, Makikomi, Tai Atari2026-01-02T13:19:47ZBackground Objectives:The biomechanics of Tori s body motion during Sutemi,sacrifice techniques,Makikomi wrapping techniques,and Tai Atari,Body Strike techniques in judo is crucial for understanding these techniques' effectiveness and safety. This study examined the biomechanics by analysing the entire body of the tori during execution. Methods:We analysed Tori s body motion using original biomechanical models, considering the balance of sacrificing to throw Uke and body mass to strike the opponent. General equations for Sutemi, Makikomi, and Tai atari were established, and their utilisation in high level male competition was statistically analysed. Results:The results show that effective Sutemi and Makikomi execution depends on the correct use of Tori's body mass.The biomechanical model revealed the relationships between angular falling speed, body angle, and athlete height.The model allowed us to evaluate the falling velocity, showing that the angular velocity and acceleration were proportional to the gravitational acceleration and body-Tatami angle and inversely proportional to the athlete height.The stopping and sliding forces are directly proportional to the sum of the Tori and Uke masses and the body Tatami angle but are independent of the athletes eight. Tai Atari s force was quantified to evaluate its situational applicability in competition. Conclusion:This study advanced the biomechanical understanding of Sutemi, Makikomi, and Tai Atari using two original theoretical models, highlighting the importance of Tori s body mass motion. The findings obtained can influence training and competition strategies, enhance technique effectiveness, and reduce injury risks.2026-01-02T13:19:47Z17 pages, 10 figures, presented at IJF Journal presented 22 October 2025, accepted 10 November 2025The Art and Sciences of Judo IJF Journal Volume 5 Number 2 2026 pages 24-39Attilio SacripantiEnvic GaleaFlorin Daniel Lascauhttp://arxiv.org/abs/2512.22270v3Measuring the time-scale-dependent information flow between maternal and fetal heartbeats during the third trimester2026-01-02T01:33:23ZPrenatal maternal stress alters maternal-fetal heart rate coupling, as demonstrated by the Fetal Stress Index derived from bivariate phase-rectified signal averaging. Here, we extend this framework using information-theoretical measures to elucidate underlying mechanisms. In 120 third-trimester pregnancies (58 stressed, 62 control), we computed transfer entropy (TE), entropy rate (ER), and sample entropy (SE) under multiple conditioning paradigms, employing mixed linear models for repeated measures. We identify dual coupling mechanisms at the short-term (0.5 - 2.5 s), but not long-term (2.5 - 5 s) time scales: (1) stress-invariant state-dependent synchronization, with maternal decelerations exerting approximately 60% coupling strength on fetal heart rate complexity - a fundamental coordination conserved across demographics; and (2) stress-sensitive temporal information transfer (TE), showing exploratory associations with maternal cortisol that require replication. A robust sex-by-stress interaction emerged in TE from mixed models, with exploratory female-specific coupling patterns absent in males. Universal acceleration predominance was observed in both maternal and fetal heart rates, stronger in fetuses and independent of sex or stress. We provide insight into the dependence of these findings on the sampling rate of the underlying data, identifying 4 Hz, commonly used for ultrasound-derived fetal heart rate recordings, as the necessary and sufficient sampling rate regime to capture the information flow. Information-theoretical analysis reveals that maternal-fetal coupling operates through complementary pathways with differential stress sensitivity, extending the Fetal Stress Index by elucidating causal foundations. Future studies should explore additional information-theoretical conditional approaches to resolve stress-specific and time-scale-specific differences in information flow.2025-12-24T22:31:10Z40 pages, 13 tables, 11 figures. GitHub repo coming shortly; Entropy code: https://github.com/nbgarnier/entropy; statistics code: https://github.com/martinfrasch/felicity1_teNicolas B. GarnierMaria S. MolinetMarta C. AntonelliSilvia M. LobmaierMartin G. Fraschhttp://arxiv.org/abs/2601.00505v1Effect of Electric Charge on Biotherapeutic Transport, Binding and Absorption: A Computational Study2026-01-01T23:11:29ZThis study explores the effects of electric charge on the dynamics of drug transport and absorption in subcutaneous injections of monoclonal antibodies (mAbs). We develop a novel mathematical and computational model, based on the Nernst-Planck equations and porous media flow theory, to investigate the complex interactions between mAbs and charged species in subcutaneous tissue. The model enables us to study short-term transport dynamics and long-term binding and absorption for two mAbs with different electric properties. We examine the influence of buffer pH, body mass index, injection depth, and formulation concentration on drug distribution and compare our numerical results with experimental data from the literature.2026-01-01T23:11:29Z27 pages, 13 figuresMario de LucioPavlos P. VlachosHector Gomezhttp://arxiv.org/abs/2501.04706v3Associations between iron and mean kurtosis in iron-rich grey matter nuclei in aging2026-01-01T05:13:50ZElevated kurtosis values have been observed in subcortical grey matter structures of patients with neurodegenerative diseases. Here we tested whether these elevated values are related to iron content, which generate magnetic fields that add to the diffusion encoding gradients. Multi-shell diffusion and multi-echo gradient echo acquisitions were used to derive mean kurtosis and iron measures (R2* and magnetic susceptibility), respectively, in subcortical grey matter nuclei and white matter tracts in a discovery cohort (110 older and 63 younger adults) and replication cohort (72 healthy older adults). Iron-rich grey matter regions exhibited higher mean kurtosis, R2*, and magnetic susceptibility and white matter regions had lower mean kurtosis in the older adult group. In both cohorts, mean kurtosis was significantly correlated with R2* and magnetic susceptibility in iron-rich grey matter nuclei. No association was seen between signal-to-noise ratio and mean kurtosis in any grey matter region, indicating that the increase in mean kurtosis was not due to reduced signal-to-noise. Finally, a phantom experiment found higher mean kurtosis as iron concentrations increased. Our findings indicate that kurtosis is associated with iron-sensitive metrics in iron-rich grey matter structures, suggesting that kurtosis may be sensitive to iron deposits.2024-12-24T02:26:17Z11 pages, 9 figures, 2 TablesJason LangleyKitzia SolisVala MasjedizadehMurphy ShaoIlana BennettXiaoping P. Huhttp://arxiv.org/abs/2601.00081v1Cuffless, calibration-free hemodynamic monitoring with physics-informed machine learning models2025-12-31T19:22:43ZWearable technologies have the potential to transform ambulatory and at-home hemodynamic monitoring by providing continuous assessments of cardiovascular health metrics and guiding clinical management. However, existing cuffless wearable devices for blood pressure (BP) monitoring often rely on methods lacking theoretical foundations, such as pulse wave analysis or pulse arrival time, making them vulnerable to physiological and experimental confounders that undermine their accuracy and clinical utility. Here, we developed a smartwatch device with real-time electrical bioimpedance (BioZ) sensing for cuffless hemodynamic monitoring. We elucidate the biophysical relationship between BioZ and BP via a multiscale analytical and computational modeling framework, and identify physiological, anatomical, and experimental parameters that influence the pulsatile BioZ signal at the wrist. A signal-tagged physics-informed neural network incorporating fluid dynamics principles enables calibration-free estimation of BP and radial and axial blood velocity. We successfully tested our approach with healthy individuals at rest and after physical activity including physical and autonomic challenges, and with patients with hypertension and cardiovascular disease in outpatient and intensive care settings. Our findings demonstrate the feasibility of BioZ technology for cuffless BP and blood velocity monitoring, addressing critical limitations of existing cuffless technologies.2025-12-31T19:22:43Z225 pages, Number of Main Figures 4, Number of Extended Data Tables 4, Number of Extended Data Figures 5, Number of Supplementary Figures 34, Number of Supplementary Tables 11, Number of Supplementary Videos 11, Supplementary Statistical Table 1 (Supplementary Table 12)Henry CrandallTyler SchuesslerFilip BělíkAlbert FabregasBarry M. StultsAlexandra BoyadzhievHuanan ZhangJim S. WuAylin R. RodanStephen P. JuraschekRamakrishna MukkamalaAlfred K. CheungStavros G. DrakosChristel HoheneggerBraxton OstingBenjamin Sanchezhttp://arxiv.org/abs/2512.25027v1Computational Analysis of Disease Progression in Pediatric Pulmonary Arterial Hypertension2025-12-31T18:27:16ZPulmonary arterial hypertension (PAH) is a progressive cardiopulmonary disease that leads to increased pulmonary pressures, vascular remodeling, and eventual right ventricular (RV) failure. Pediatric PAH remains understudied due to limited data and the lack of targeted diagnostic and therapeutic strategies. In this study, we developed and calibrated multi-scale, patient-specific cardiovascular models for four pediatric PAH patients using longitudinal MRI and catheterization data collected approximately two years apart. Using the CRIMSON simulation framework, we coupled three-dimensional fluid-structure interaction (FSI) models of the pulmonary arteries with zero-dimensional (0D) lumped-parameter heart and Windkessel models to simulate patient hemodynamics. An automated Python-based optimizer was developed to calibrate boundary conditions by minimizing discrepancies between simulated and clinical metrics, reducing calibration time from weeks to days. Model-derived metrics such as arterial stiffness, pulse wave velocity, resistance, and compliance were found to align with clinical indicators of disease severity and progression. Our findings demonstrate that computational modeling can non-invasively capture patient-specific hemodynamic adaptation over time, offering a promising tool for monitoring pediatric PAH and informing future treatment strategies.2025-12-31T18:27:16ZOmar SaidChristopher Tossas-BetancourtMary K. OliveJimmy C. LuAdam DorfmanC. Alberto Figueroahttp://arxiv.org/abs/2512.24820v1Circuit-free cardiovascular monitoring via skin-interfaced nanophotonics2025-12-31T12:14:24ZContinuous cardiovascular monitoring is essential for managing circulatory health and disease, yet most wearable sensors are constrained by reliance on electrical transduction and built-in electronics. We present a circuit-free, wholly optical approach using diffraction from a skin-interfaced nanostructured surface to detect minute skin strains from the arterial pulse. A smartphone camera records the shifting diffraction pattern in real time, removing the need for spectrometers or other optical hardware. In phantom and human studies, we recovered high-fidelity arterial pulse waves and detected benign arrhythmic events in close agreement with a clinical reference. Derived waveforms captured features linked to arterial stiffness, a key cardiovascular risk marker. Our approach uses battery-free, cost-effective, and disposable platforms enabling scalable monitoring for healthcare and broad consumer applications.2025-12-31T12:14:24ZTorjus L. SteffensenArthur G. S. TorvundVegar StubberudJulia LövgrenNils K. SkjærvoldMartin R. SteinertAngelos Xomalis