https://arxiv.org/api/UN37pbWbIBC4iaC+2Dkbxx85UZg 2026-06-22T18:23:18Z 8985 525 15 http://arxiv.org/abs/2601.05063v1 Quantitative mapping from conventional MRI using self-supervised physics-guided deep learning: applications to a large-scale, clinically heterogeneous dataset 2026-01-08T16:08:58Z Magnetic resonance imaging (MRI) is a cornerstone of clinical neuroimaging, yet conventional MRIs provide qualitative information heavily dependent on scanner hardware and acquisition settings. While quantitative MRI (qMRI) offers intrinsic tissue parameters, the requirement for specialized acquisition protocols and reconstruction algorithms restricts its availability and impedes large-scale biomarker research. This study presents a self-supervised physics-guided deep learning framework to infer quantitative T1, T2, and proton-density (PD) maps directly from widely available clinical conventional T1-weighted, T2-weighted, and FLAIR MRIs. The framework was trained and evaluated on a large-scale, clinically heterogeneous dataset comprising 4,121 scan sessions acquired at our institution over six years on four different 3 T MRI scanner systems, capturing real-world clinical variability. The framework integrates Bloch-based signal models directly into the training objective. Across more than 600 test sessions, the generated maps exhibited white matter and gray matter values consistent with literature ranges. Additionally, the generated maps showed invariance to scanner hardware and acquisition protocol groups, with inter-group coefficients of variation $\leq$ 1.1%. Subject-specific analyses demonstrated excellent voxel-wise reproducibility across scanner systems and sequence parameters, with Pearson $r$ and concordance correlation coefficients exceeding 0.82 for T1 and T2. Mean relative voxel-wise differences were low across all quantitative parameters, especially for T2 ($<$ 6%). These results indicate that the proposed framework can robustly transform diverse clinical conventional MRI data into quantitative maps, potentially paving the way for large-scale quantitative biomarker research. 2026-01-08T16:08:58Z 30 pages, 13 figures, full paper Jelmer van Lune Stefano Mandija Oscar van der Heide Matteo Maspero Martin B. Schilder Jan Willem Dankbaar Cornelis A. T. van den Berg Alessandro Sbrizzi http://arxiv.org/abs/2601.05045v1 Dosimetric Impact of Hidden Input Parameters in Inverse Optimization Algorithms for GYN HDR Brachytherapy 2026-01-08T15:51:24Z Inverse optimization (IO) algorithms are used in GYN HDR brachytherapy planning, with user parameter settings embedded in commercial TPS. To examine the dosimetric influence of hidden input parameters in three IO algorithms-IPSA, HIPO, and MCO-for GYN HDR brachytherapy across two applicator types. In-house implementations of IPSA, HIPO, and MCO were implemented and evaluated against retrospectively generated commercial TPS plans (Oncentra Brachy) using identical clinical input parameters across 24 cervical cancer cases (18 T&O; 6 T&O+Needles (T&O+N)). Each IO algorithm was assessed using 1k combinations of hidden parameters (e.g., dwell-time modulation constraints, convergence thresholds). Cumulative DVH curves and dosimetric indices (HR-CTV D98/D90, OAR D2cc) were compared with commercial plans. Standard deviations (SD) of DVH differences were used to characterize sensitivity to hidden parameters. For HR-CTV, SD values in T&O+N cases reached 23.0 Gy and 7.1 Gy for MCO and HIPO, respectively, with corresponding average values of 55.8 Gy and 19.7 Gy. In T&O cases, HR-CTV SD values reached 4.9 Gy and 3.3 Gy for HIPO and IPSA, respectively, with average values of 20.1 Gy and 8.6 Gy. MCO exhibited the highest sensitivity, followed by HIPO and IPSA. T&O+N cases showed greater sensitivity than T&O cases. Absolute differences in HR-CTV D90 (D98) relative to commercial algorithms reached up to 33.3 Gy (28.4) for T&O+N cases and 10.8 Gy (8.5) for T&O cases. For OARs, absolute D2cc differences in T&O+N (T&O) cases reached up to 8.6 Gy (2.3) for rectum, 17 Gy (10.2) for bladder, 14.8 Gy (3.9) for sigmoid, and 7.0 Gy (8.1) for bowel. Hidden input parameter settings significantly impact on GYN HDR plans, with target coverage up to 28.4 Gy across IO algorithms for both T&O and T&O+N cases. The findings in this study shown the potential to improve plans through hidden input parameter optimization. 2026-01-08T15:51:24Z 4 pages, 3 figures, 3 tables YeongHyeon Park Shiqin Su Sarath Vijayan Zhiqian Henry Yu Mandy Cunningham Yusung Kim http://arxiv.org/abs/2601.04821v1 Bi-level Multi-criteria Optimization for Risk-informed Radiotherapy 2026-01-08T10:57:53Z In radiation therapy (RT) treatment planning, multi-criteria optimization (MCO) supports efficient plan selection but is usually solved for population-based dosimetric criteria and ignores patient-specific biological risk, potentially compromising outcomes in high-risk patients. We propose risk-guided MCO, a one-shot method that embeds a clinical risk model into conventional MCO, enabling interactive navigation between dosimetric and biological endpoints. The proposed algorithm uses a special order relation to fuse the classical MCO sandwiching algorithm with bi-level optimization, restricting the Pareto set to plans that achieve improvement in the secondary risk objective for user-defined, acceptable loss in primary clinical objectives. Thus, risk-guided MCO generates risk-optimized counterparts of clinical plans in a single run rather than by sequential or lexicographic planning. To assess the performance, we retrospectively analyzed 19 lung cancer patients treated with RT. The endpoint was the risk of grade 2+ radiation pneumonitis (RP), modeled using bootstrapped stepwise logistics regression with interaction terms, including baseline lung function, smoking history, and dosimetric factors. The risk-guided plans yielded a mean reduction of 8.0% in total lung V20 and 9.5% in right lung V5, translating into an average RP risk reduction of 7.7% (range=0.3%-20.1%), with small changes in target coverage (mean -1.2 D98[%] for CTV) and modest increase in heart dose (mean +1.74 Gy). This study presents the first proof-of-concept for integrating biological risk models directly within multi-criteria RT planning, enabling an interactive balance between established population-wide dose protocols and individualized outcome prediction. Our results demonstrate that the risk-informed MCO can reduce the risk of RP while maintaining target coverage. 2026-01-08T10:57:53Z Mara Schubert Katrin Teichert Zhongxing Liao Thomas Bortfeld Ali Ajdari http://arxiv.org/abs/2503.20107v2 Federated Learning: A new frontier in the exploration of multi-institutional medical imaging data 2026-01-07T21:43:09Z Artificial intelligence has transformed the perspective of medical imaging, leading to a genuine technological revolution in modern computer-assisted healthcare systems. However, ubiquitously featured deep learning (DL) systems require access to a considerable amount of data, facilitating proper knowledge extraction and generalization. Access to such extensive resources may be hindered due to the time and effort required to convey ethical agreements, set up and carry the acquisition procedures through, and manage the datasets adequately with a particular emphasis on proper anonymization. One of the pivotal challenges in the DL field is data integration from various sources acquired using different hardware vendors, diverse acquisition protocols, experimental setups, and even inter-operator variabilities. In this paper, we review the federated learning (FL) concept that fosters the integration of large-scale heterogeneous datasets from multiple institutions in training DL models. In contrast to a centralized approach, the decentralized FL procedure promotes training DL models while preserving data privacy at each institution involved. We formulate the FL principle and comprehensively review general and specialized medical imaging aggregation and learning algorithms, enabling the generation of a globally generalized model. We meticulously go through the challenges in constructing FL-based systems, such as data and model heterogeneities across the institutions, resilience to potential attacks on data privacy, and the variability in computational and communication resources among the entangled sites that might induce efficiency issues of the entire system. Finally, we explore the up-to-date open frameworks for rapid FL-based algorithm prototyping, comprehensively present real-world implementations of FL systems and shed light on future directions in this intensively growing field. 2025-03-25T23:08:36Z Dominika Ciupek Maciej Malawski Tomasz Pieciak http://arxiv.org/abs/2601.03827v1 Objective comparison of auditory profiles using manifold learning and intrinsic measures 2026-01-07T11:47:32Z Assigning individuals with hearing impairment to auditory profiles can support a better understanding of the causes and consequences of hearing loss and facilitate profile-based hearing-aid fitting. However, the factors influencing auditory profile generation remain insufficiently understood, and existing profiling frameworks have rarely been compared systematically. This study therefore investigated the impact of two key factors - the clustering method and the number of profiles - on auditory profile generation. In addition, eight established auditory profiling frameworks were systematically reviewed and compared using intrinsic statistical measures and manifold learning techniques. Frameworks were evaluated with respect to internal consistency (i.e., grouping similar individuals) and cluster separation (i.e., clear differentiation between groups). To ensure comparability, all analyses were conducted on a common open-access dataset, the extended Oldenburg Hearing Health Record (OHHR), comprising 1,127 participants (mean age = 67.2 years, SD = 12.0). Results showed that both the clustering method and the chosen number of profiles substantially influenced the resulting auditory profiles. Among purely audiogram-based approaches, the Bisgaard auditory profiles demonstrated the strongest clustering performance, whereas audiometric phenotypes performed worst. Among frameworks incorporating supra-threshold information in addition to the audiogram, the Hearing4All auditory profiles were advantageous, combining a near-optimal number of profile classes (N = 13) with high clustering quality, as indicated by a low Davies-Bouldin index. In conclusion, manifold learning and intrinsic measures enable systematic comparison of auditory profiling frameworks and identify the Hearing4All auditory profile as a promising approach for future research. 2026-01-07T11:47:32Z Chen Xu Birger Kollmeier Lena Schell-Majoor http://arxiv.org/abs/2508.11100v3 Full-Wave Modeling of Transcranial Ultrasound using Volume-Surface Integral Equations and CT-Derived Heterogeneous Skull Data 2026-01-07T03:53:49Z Transcranial ultrasound therapy uses focused acoustic energy to induce therapeutic bioeffects in the brain. Ultrasound must be transmitted through the skull, which is highly attenuating and heterogeneous, causing beam distortion, reducing focal pressure, and shifting the target location. Computational models are frequently used to predict beam aberration, assess cranial heating, and correct the phase of ultrasound transducers. These models often rely on computed tomography (CT) images to build patient-specific geometries and estimate skull acoustic properties. However, the coarse voxel resolution of CT limits accuracy for differential equation solvers at ultrasound frequencies. This paper presents an efficient numerical method based on volume-surface integral equations to model full-wave acoustic propagation through heterogeneous skull bone. We show that our approach effectively simulates transcranial ultrasound, even when using the original CT voxels as the computational mesh, where the 0.5 mm voxel length is relatively coarse compared to the shortest wavelength of 3 mm. The method is validated against a high-resolution boundary element model using an averaged skull representation. Simulations using a CT-based skull model and a bowl transducer reveal significant beam distortion of 7.8 mm attributed to the skull's heterogeneous acoustical properties. 2025-08-14T22:39:24Z Alberto Almuna-Morales Danilo Aballay Pierre Gélat Reza Haqshenas Elwin van 't Wout 10.1016/j.ultras.2026.107954 http://arxiv.org/abs/2601.03224v1 Open-Source Coil Matching Toolbox for Magnetic Stimulation and Other Electromagnetics (COMATOSE) 2026-01-06T18:12:33Z The coil in transcranial magnetic stimulation (TMS) determines the spatial shape of the electromagnetic field in the head, which structures are concurrently activated, and how focal stimulation is. Most of the readily available coils have been designed intuitively instead of systematic mathematical-physical optimization as there were no methods available at the time. Previous research however demonstrated that these coils are far from optimum, e.g., for pulse energy or efficiency, and leave substantial room for lots of improvements. Techniques for rigorous mathematical optimization have been developed but are only available to very few groups worldwide. This paper presents an open-source toolbox, COMATOSE, to change that situation and make these methods available to a wider community. It incorporates the fundamental formalisms and offers vector space decomposition as well as base mapping as an explicit forward method, which is computationally less demanding than iterative computational optimization but can also form the initial solution for a subsequent optimization run if desired. 2026-01-06T18:12:33Z 5 pages, 1 figure Max Koehler Stefan Goetz http://arxiv.org/abs/2601.03172v1 Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs 2026-01-06T16:52:08Z Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI. 2026-01-06T16:52:08Z Szymon Parzych Szymon Niedźwiecki Ermias Yitayew Beyene Neha Chug Maurizio Conti Catalina Curceanu Eryk Czerwiński Manish Das Kavya Valsan Eliyan Jakub Hajduga Sharareh Jalali Krzysztof Kacprzak Tevfik Kaplanoglu Łukasz Kapłon Kamila Kasperska Aleksander Khreptak Grzegorz Korcyl Tomasz Kozik Deepak Kumar Anoop Kunimmal Venadan Karol Kubat Edward Lisowski Filip Lisowski Justyna Mędrala-Sowa Wiktor Mryka Simbarashe Moyo Piyush Pandey Elena Perez del Rio Alessio Porcelli Bartłomiej Rachwał Martin Rädler Axel Rominger Sushil Sharma Kuangyu Shi Magdalena Skurzok William M. Steinberger Tomasz Szumlak Pooja Tanty Keyvan Tayefi Ardebili Satyam Tiwari Ewa Łucja Stępień Paweł Moskal http://arxiv.org/abs/2504.19155v3 Machine Learning-Based Modeling of the Anode Heel Effect in X-ray Beam Monte Carlo Simulations 2026-01-06T13:52:31Z To develop a machine learning-based framework for accurately modeling the anode heel effect in Monte Carlo simulations of X-ray imaging systems, enabling realistic beam intensity profiles with minimal experimental calibration. Multiple regression models were trained to predict spatial intensity variations along the anode-cathode axis using experimentally acquired weights derived from beam measurements across different tube potentials. These weights captured the asymmetry introduced by the anode heel effect. A systematic fine-tuning protocol was established to minimize the number of required measurements while preserving model accuracy. The models were implemented in the OpenGATE 10 and GGEMS Monte Carlo toolkits to evaluate their integration feasibility and predictive performance. Among the tested models, gradient boosting regression (GBR) delivered the highest accuracy, with prediction errors remaining below 5% across all energy levels. The optimized fine-tuning strategy required only six detector positions per energy level, reducing measurement effort by 65%. The maximum error introduced through this fine-tuning process remained below 2%. Dose actor comparisons within Monte Carlo simulations demonstrated that the GBR-based model closely replicated clinical beam profiles and significantly outperformed conventional symmetric beam models. This study presents a robust and generalizable method for incorporating the anode heel effect into Monte Carlo simulations using machine learning. By enabling accurate, energy-dependent beam modeling with limited calibration data, the approach enhances simulation realism for applications in clinical dosimetry, image quality assessment, and radiation protection. 2025-04-27T08:19:47Z 15 pages, 8 figures Phys. Med. Biol. 71, 015007 (2026) Hussein Harb Didier Benoit Axel Rannou Chi-Hieu Pham Valentin Tissot Bahaa Nasr Julien Bert 10.1088/1361-6560/ae2cdf http://arxiv.org/abs/2601.03313v1 Fine and Hyperfine Interactions with Multi-level Spin Relaxation of the purified Giese-Salt in Veterinary Medicine: Prussian Blue Compound Ammonium-Ferric-Hexacyano-Ferrate 2026-01-06T12:39:30Z Ammonium ferric hexacyanoferrate is a veterinary-medical milestone and antidote against radiocesium, well-known as Giese-salt after the Chernobyl disaster fed to domestic and wild animals, which shows even a rich interplay of properties in nanostructural chemistry and ferromagnetism. Among the broad analytical techniques, the ambivalence of macroscopic micrometer-sized agglomerates and nanoparticle sizes, a suggested enlarged Fe(II)$-$C$\equiv$N$-$Fe(III) bond length by Fe K-edge XAFS results and multi-level spin relaxation in $^{57}$Fe Mössbauer spectroscopy are highlighted. This sets this underestimated compound in a new light, e.g., for modern biomedicine and biofunctionality, extending its essential importance in addition to hypothetical future nuclear incidents 2026-01-06T12:39:30Z 47 pages Sascha Albert Bräuninger Damian Alexander Motz Sebastian Praetz Felix Seewald Katharina Strecker Carla Vogt Hans-Henning Klauss Birgit Kanngießer Hermann Seifert 10.1007/s10967-026-10838-8 http://arxiv.org/abs/2601.02538v1 A Green Solution for Breast Region Segmentation Using Deep Active Learning 2026-01-05T20:25:34Z Purpose: Annotation of medical breast images is an essential step toward better diagnostic but a time consuming task. This research aims to focus on different selecting sample strategies within deep active learning on Breast Region Segmentation (BRS) to lessen computational cost of training and effective use of resources. Methods: The Stavanger breast MRI dataset containing 59 patients was used in this study, with FCN-ResNet50 adopted as a sustainable deep learning (DL) model. A novel sample selection approach based on Breast Anatomy Geometry (BAG) analysis was introduced to group data with similar informative features for DL. Patient positioning and Breast Size were considered the key selection criteria in this process. Four selection strategies including Random Selection, Nearest Point, Breast Size, and a hybrid of all three strategies were evaluated using an active learning framework. Four training data proportions of 10%, 20%, 30%, and 40% were used for model training, with the remaining data reserved for testing. Model performance was assessed using Dice score, Intersection over Union, precision, and recall, along with 5-fold cross-validation to enhance generalizability. Results: Increasing the training data proportion from 10% to 40% improved segmentation performance for nearly all strategies, except for Random Selection. The Nearest Point strategy consistently achieved the lowest carbon footprint at 30% and 40% data proportions. Overall, combining the Nearest Point strategy with 30% of the training data provided the best balance between segmentation performance, efficiency, and environmental sustainability. Keywords: Deep Active Learning, Breast Region Segmentation, Human-center analysis 2026-01-05T20:25:34Z Sam Narimani Solveig Roth Hoff Kathinka Dæhli Kurz Kjell-Inge Gjesdal Jürgen Geisler Endre Grøvik http://arxiv.org/abs/2508.10527v2 A 240 Elements Matrix Probe with Aberration Mask for 4D Carotid Artery Computational Ultrasound Imaging 2026-01-05T15:15:31Z Three-dimensional (3D) ultrasound provides enhanced visualization of the carotid artery (CA) anatomy and volumetric flow, offering improved accuracy for cardiovascular diagnosis and monitoring. However, fully populated matrix transducers with large apertures are complex and costly to implement. Computational ultrasound imaging (cUSi) offers a promising alternative by enabling simplified hardware design through model-based reconstruction and spatial field encoding. In this work, we present a 3D cUSi system tailored for CA imaging, consisting of a 240-element matrix probe with a 40 x 24 mm$^2$ large aperture and a spatial encoding mask. We describe the system's design, characterization, and image reconstruction. Phantom experiments show that computational reconstruction using matched filtering (MF) significantly improves volumetric image quality over delay-and-sum (DAS), with spatial encoding enhancing lateral resolution at the cost of reduced contrast ratio. LSQR-based reconstruction was demonstrated to further improve resolution and suppress artifacts. Using both Hadamard and 16-angle plane wave transmission schemes, the system achieved high-resolution images with reasonable contrast, supporting the feasibility of 4D CA imaging applications. 2025-08-14T11:02:21Z Maintext: 11 pages, 7 figures Supporting: 2 pages Yuyang Hu Michael Brown Didem Dogan Mahé Bulot Maxime Cheppe Guillaume Ferin Geert Leus Antonius F. W. van der Steen Pieter Kruizinga Johannes G. Bosch http://arxiv.org/abs/2601.02146v1 Investigating the impact of copper-PEDOT:PSS matrix towards non-enzymatic electrochemical creatinine detection 2026-01-05T14:19:19Z Electrochemical creatinine sensors offer great promise towards rapid, reagent-free and point-of-care (POC) kidney-function monitoring. However, challenges related to analyte binding, data reproducibility, sensitivity, fouling and device degradation deter its widespread implementation. Here, we show how a carbon electrode modified with a combination of poly(3,4-ethylene dioxythiophene): poly(styrene sulfonate) (PEDOT:PSS) and copper nanoparticles (CuNPs) can rapidly and accurately detect creatinine (CT) in artificial urine media employing electrochemical techniques. Applying redox potential sweeps (vs Ag/AgCl) using copper sulfate (CuSO4) solution on such sensor facilitates the CuNP embedding process inside the conjugated polymer matrix which has been further validated by supporting techniques. We predicted and validated the formation and contribution of two Cu-CT coordination complexes corresponding to Cu(I) and Cu(II) states, which are responsible for CT detection. The fabricated CT sensor exhibits high selectivity against major artificial urine interferents and is stable for a month showing minimal degradation (0.53%) in peak current value. Such sensors can be utilized to detect and monitor different stages of renal failure in real-time patient samples. 2026-01-05T14:19:19Z 18 pages, 5 figures, 1 table Chirantan Das Subhrajit Sikdar Shreyas K. Vasantham Piotr Pięta Marcin Strawski Marcin S. Filipiak Paweł Borowicz Yurii Promovych Piotr Garstecki http://arxiv.org/abs/2512.18793v2 Quantitative ultrasound imaging of bone: anatomical images, tissue structural quality, and pulsatile blood flow 2026-01-05T14:02:55Z We propose an ultrasound approach which provides, with one single examination and one single device, access to three bone biomarkers: anatomy, tissue quality and blood flow. It unlocks ultrasound imaging inside bone by accounting for ultrasound wave speed heterogeneity and anisotropic wave refraction. This study reports the first \emph{in vivo} evaluation with a comparison to peripheral Quantitative Computed Tomography (pQCT) and modulations of blood flow. Anatomical multi-layer bone-corrected reconstruction was validated at the tibia of healthy volunteers against pQCT and showed agreement on bone cortex interfaces. Estimation of axial and radial ultrasound wave speeds in cortical bone tissue (i.e. along the tissue symmetry axis and normal to it) demonstrated good reproducibility and positive correlation with bone mineral density measured by pQCT. Pulsatile blood flow was mapped and quantified in cortical and medullary regions. A directional ray selection method was developed to enhance blood signal extraction by reducing strong specular reflections originating from the outer and inner surfaces of the bone cortex. Physiological and non-physiological modulations of blood flow, namely head-up/head-down tilt table maneuvers and arterial occlusions, demonstrated the method sensitivity to blood flow variations. For the first time, reactive hyperemia was observed inside bone cortex. These results demonstrate the feasibility of a portable, non-ionizing, and quantitative ultrasound approach for structural, anatomical, and vascular characterization of bone tissue. This approach may offer new diagnostic capabilities for bone disorders, for instance osteoporosis, delayed fracture healing or osteonecrosis. 2025-12-21T16:10:59Z Gabrielle Laloy-Borgna Nastassia Navasiolava Pim Hutting Andréa Bertona Amadou S. Dia Sébastien Salles Anthony Augé Alice Mazzolini Quentin Grimal Olivier Lucidarme Hervé Locrelle Jacques-Olivier Fortrat Laurence Vico Marc-Antoine Custaud Guillaume Renaud http://arxiv.org/abs/2510.02847v4 Dipolar order mapping based on spin-lock magnetic resonance imaging 2026-01-05T03:39:22Z Purpose: Inhomogeneous magnetization transfer (ihMT) effect reflects dipolar order with a dipolar relaxation time ($T_{1D}$), specific to motion-restricted macromolecules. We aim to quantify $T_{1D}$ using spin-lock MRI technique. Methods: In the proposed method, we introduce a $T_{1D}$-specific ratio, denoted as $RATIO_{dosl}$. This ratio is derived from the distinct relaxation rate $R_{dosl}$, calculated as the difference between dual-frequency relaxation $R_{1ρ}^{dual}$ and single-frequency $R_{1ρ}^{single}$ relaxation measurements. A novel rotary-echo spin-lock sequence was developed to enable dual-frequency spin-lock acquisition. We established a framework to estimate $T_{1D}$, as well as the macromolecular pool fraction (MPF) map. The proposed approach was validated via numerical simulations, phantom studies, and demonstrated in vivo in human white matter. Results: Simulations revealed the high sensitivity of $RATIO_{dosl}$ to $T_{1D}$, and substantiated the accuracy and robustness of the proposed methods. Phantom experiments demonstrated robust ihMT contrast and confirmed the capability of $T_{1D}$ quantification via $RATIO_{dosl}$. In vivo studies supported the clinical viability of this approcah, achieving simultaneous $T_{1D}$ and MPF mapping using only three spin-lock prepared images. Across ten healthy volunteers, the mean white matter $T_{1D}$ ranged from approximately 3.70 to 4.80 ms. Conclustion: We propose a novel method for $T_{1D}$ quantification based on spin-lock MRI. By requiring only three contrast-prepared images, this technique provides a promising pathway for robust, rapid, and simultaneous $T_{1D}$ and MPF quantification with fewer confounds 2025-10-03T09:34:06Z Zijian Gao Qianxue Shan Ziqin Zhou Ziqiang Yu Weitian Chen