https://arxiv.org/api/3UC3J1rkm9vGk5zxrcrNtOBhBL02026-06-22T15:08:06Z898548015http://arxiv.org/abs/2601.17463v1Polyurethane-Based Scintillators for Neutron and Gamma Radiation Detection in Medical and Industrial Applications2026-01-24T13:27:53ZOrganic scintillators using a solid polyurethane (PU) matrix have been introduced to combine the robustness of a construction material with scintillating properties that allow gamma rays and fast neutrons to be detected efficiently and at low cost. This work compares two corresponding materials, the older M600 and the more recent M700, with EJ-276D and EJ-200 representing common plastic scintillators with and without pulse-shape discrimination (PSD) capabilities, respectively. Characterization measurements were performed with small samples of 26 mm diameter and 10 mm height, which were coupled to a photomultiplier tube (PMT) and simultaneously exposed to 252Cf fission neutrons and 137Cs gamma rays. M700 turned out to provide the best PSD performance and about the same light yield as EJ-276D, while its light pulses exhibit a shorter pulse decay. An accelerated ageing process applied in between two test campaigns was too short to trigger distinct performance degradation in any of the materials, though optical degradation was visible in EJ-276D and in EJ-200 but not in the PU-based materials. Nevertheless, the extremely robust polyurethane matrix promises advantages in medical and industrial applications where resilience and long-term stability are of crucial importance.2026-01-24T13:27:53ZOlga MaiatskaTorsten DünnebackeMartin KreuelsGuntram PauschFalko ScherwinskiJürgen R. Steinhttp://arxiv.org/abs/2601.10336v2Radiation Shielding Performance of Different Concrete Materials: A Systematic Review2026-01-24T03:24:07ZBackground: Concrete is one of the most-used material today in nuclear, medical, and industrial applications for radiation shielding due to its economic advantages and availability together with its structural performance. However, differences in the use of aggregates, density, and other additives affect radiation attenuation efficiency. It is therefore necessary to understand and compare shielding properties of various concrete formulations for the optimization of safety and performance in radiation-prone environments. Methods: Using Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, a literature search was performed across PubMed, Scopus, ScienceDirect, and Google Scholar. 17 peer-reviewed studies published between 2010 and 2025 were analysed systematically. Data was extracted based on material composition, density, radiation type, energy range, attenuation coefficients, and shielding efficiency. The obtained results were compared to find the trend in performance and optimization of the considered materials. Conclusion: Radiation shielding efficiency of concrete is dependent on its density, microstructural characteristics and type of aggregate. For superior performance in a mixed radiation field, Heavy and boron-rich additives can be added. Newly developed UHPCs and nano-engineered concretes are lightweight, durable, and environmentally friendly options for shielding materials compared to traditional ones. Further studies are needed to focus on the standardization of test methods, validation of long-term stability, and coupling computational modelling with experimental data in order to guide material design for applications featuring enhanced radiation shielding.2026-01-15T12:26:29Z16 Pages. 01 FigureChristiana SubaarZiem Samuel AanonedaSylivia BoatengEmmanuella Konadu AmaniampongPhilimon Adjeihttp://arxiv.org/abs/2601.17190v1Circularly polarized metamaterial cage for homogeneous signal-to-noise ratio enhancement in magnetic resonance imaging2026-01-23T21:42:37ZThe signal-to-noise ratio (SNR) in magnetic resonance imaging (MRI) governs the quality of signal detection and directly impacts the clarity and reliability of the acquired images. Recent advances in metamaterials have enabled lightweight solutions with selective magnetic responses, offering a route to locally boost SNR in targeted anatomical regions but often with compromised field homogeneity. Here, a wireless metamaterial cage constructed from coaxial cables is engineered for homogeneous SNR enhancement at 3.0 T. With its cylindrical geometry and electromagnetic architecture, the device supports circularly polarized resonance through engineered phase-shifted currents, enabling selective and omnidirectional interaction with the rotating B_1^- field to achieve uniform magnetic field distribution. Integrated with the body coil, the device yields a 32-fold SNR enhancement while maintaining comparable homogeneity to the body coil alone, exhibiting only 12.07% variation within the region of interest (ROI). Benchmarking against a state-of-the-art 16-channel extremity coil further shows that the metacage achieves at least 1.94-fold and 2.24-fold higher SNR in axial and coronal planes, respectively, and exhibits substantially lower SNR variation (12.07% compared to 54.83% for the extremity coil). The results establish the metacage as a compelling platform for next-generation wireless MRI technologies.2026-01-23T21:42:37Z23pages, 5 figuresYuhan LiuXia ZhuKe WuStephan W. AndersonXin Zhanghttp://arxiv.org/abs/2601.17165v1Benchmarking Deep Learning-Based Reconstruction Methods for Photoacoustic Computed Tomography with Clinically Relevant Synthetic Datasets2026-01-23T20:52:35ZDeep learning (DL)-based image reconstruction methods for photoacoustic computed tomography (PACT) have developed rapidly in recent years. However, most existing methods have not employed standardized datasets, and their evaluations rely on traditional image quality (IQ) metrics that may lack clinical relevance. The absence of a standardized framework for clinically meaningful IQ assessment hinders fair comparison and raises concerns about the reproducibility and reliability of reported advancements in PACT. A benchmarking framework is proposed that provides open-source, anatomically plausible synthetic datasets and evaluation strategies for DL-based acoustic inversion methods in PACT. The datasets each include over 11,000 two-dimensional (2D) stochastic breast objects with clinically relevant lesions and paired measurements at varying modeling complexity. The evaluation strategies incorporate both traditional and task-based IQ measures to assess fidelity and clinical utility. A preliminary benchmarking study is conducted to demonstrate the framework's utility by comparing DL-based and physics-based reconstruction methods. The benchmarking study demonstrated that the proposed framework enabled comprehensive, quantitative comparisons of reconstruction performance and revealed important limitations in certain DL-based methods. Although they performed well according to traditional IQ measures, they often failed to accurately recover lesions. This highlights the inadequacy of traditional metrics and motivates the need for task-based assessments. The proposed benchmarking framework enables systematic comparisons of DL-based acoustic inversion methods for 2D PACT. By integrating clinically relevant synthetic datasets with rigorous evaluation protocols, it enables reproducible, objective assessments and facilitates method development and system optimization in PACT.2026-01-23T20:52:35ZPanpan ChenSeonyeong ParkGangwon JeongRefik Mert CamUmberto VillaMark A. Anastasiohttp://arxiv.org/abs/2507.13118v3Analytic Model of Trans-axial Sensitivity in Cylindrical PET Systems Based on Solid Angle2026-01-23T04:08:53ZIn positron emission tomography (PET), a clear theoretical model describing how system sensitivity varies as a source is moved trans-axially within the field of view (FOV) is lacking. The current understanding and practical intuition often suggest that sensitivity is maximum at the center of the FOV, an assumption reflected in standardized protocols. In this work, we derive an analytic model for the trans-axial-plane sensitivity distribution in a cylindrical PET scanner based on solid angle. The model, formulated as a function of trans-axial offset from the center, is validated through both Monte Carlo simulations and physical experiments on a representative system. We find that the derived theoretical distribution is essentially consistent with simulation and experimental results, revealing a non-intuitive feature: sensitivity increases with trans-axial offset, peaks at the edge of the FOV, and drops off sharply beyond it. This study provides the first closed-form model of trans-axial geometric sensitivity in cylindrical PET scanners, offering a vital benchmark for isolating detector technology improvements and revealing a non-intuitive, offset-dependent sensitivity profile that enables new protocol optimization strategies.2025-07-17T13:33:23Z17 pages, 7 figuresBoheng LinZizhuo XieBo ZhangLin WanAo QiuQingguo Xiehttp://arxiv.org/abs/2601.15947v1Multimodal Imaging System Combining Hyperspectral and Laser Speckle Imaging for In Vivo Hemodynamic and Metabolic Monitoring2026-01-22T13:32:34ZWe present the development and validation of a novel multimodal optical imaging platform that integrates hyperspectral imaging (HSI) and laser speckle contrast imaging (LSCI) to enable real-time, non-invasive mapping of tissue oxygenation, perfusion and metabolism, via blood flowmetry and targeting of oxy- (HbO2), deoxyhemoglobin (HHb), as well as oxidized cytochrome-c-oxidase (oxCCO). The system architecture features a single high-speed camera and dual optical path, with synchronized alternating illumination: a filtered, supercontinuum laser for HSI and a He-Ne laser for LSCI. The system performances were evaluated through in vivo experiments on rat spinal cord under normoxic and hypoxic conditions, revealing coherent physiological changes in hemodynamics, metabolism and relative blood flow index (rBFI). These results demonstrate the potential of the platform for functional tissue imaging and quantitative dynamic monitoring of both oxygen delivery and consumption.2026-01-22T13:32:34ZJunda WangLuca GiannoniAyse Gertrude YenicelikEleni GiamaFrederic LangeKenneth J. SmithIlias Tachtsidishttp://arxiv.org/abs/2601.15073v1A combined dose and microdosimetric modeling framework incorporating volume effects correlates with tissue sparing in proton minibeam radiotherapy2026-01-21T15:16:39ZProton minibeam (pMB) radiotherapy, delivers highly heterogeneous dose distributions alternating high-dose peaks and low-dose valleys. This aims to widen the therapeutic window by improving normal tissue sparing while maintaining the same or even better tumour control. The performance of pMB strongly depends on the collimator design and physical parameters. To better understand the physical and radiobiological drivers of this enhanced therapeutic window, we perform a detailed microdosimetric characterization of proton minibeams and assess their impact.
We characterize radiation quality with microdosimetry through Monte Carlo simulations. Then we extend the Generalized Stochastic Microdosimetric Model to predict the normal tissue complication probability (NTCP) at different depths in water, 1cm, 2cm, and 4cm, for 100MeV proton minibeams realized with varying configurations of collimator. Results are compared with conventional homogeneous field (HF) irradiation after dose normalization to the tumor. The developed model is applied by considering tissues as divided into several functional subunits, connected by a seriality parameter.
Microdosimetric characterization of proton minibeam irradiation shows differences between peak and valley regions in shaping lineal energy spectra, especially at low depth, while radiation quality uniforms progressively getting closer to the tumor. NTCP calculations results suggest an increased sparing effect for pMB over conventional HF. A strong dependence is found on the peak-to-valley dose ratio (PVDR), and on the seriality parameter. Predictions indicate substantial sparing from pMB, especially for PVDR > 15, including relatively serial organs with seriality around 0.7.
This integrated dose-microdosimetric-biological framework elucidates how spatial fractionation, radiation quality, and organ architecture collectively shape tissue sparing in pMB.2026-01-21T15:16:39ZGiulio BordieriMarco BattestiniGianluca LattanziFrancesco RomanoEmanuele ScifoniMarta MissiaggiaFrancesco Giuseppe Cordonihttp://arxiv.org/abs/2601.14999v1LiDRoSIS: An Automated MATLAB-Python Platform for Image Processing and Quantitative Analysis of Lipid Droplets and ROS in Irradiated Cells2026-01-21T13:57:03ZLiDRoSIS is an automated MATLAB-Python software suite for the segmentation and quantification of lipid droplets (LDs) and reactive oxygen species (ROS) in fluorescence microscopy images of irradiated A549 and MCF7 cells exposed to gold-based nanoparticles. It combines classical image processing algorithms with statistical post-analysis through a companion Python tool, StatLysis. The platform enables reproducible, high-throughput analysis of morphological and spectral parameters linked to nanoparticle-enhanced radiobiological responses. By bridging imaging and quantitative analytics, LiDRoSIS provides a robust framework for nanomedicine and radiation biology research.2026-01-21T13:57:03Z7 pages, 3 figures. Software and data available at https://github.com/marco18010104/LiDRoSIS and https://doi.org/10.5281/zenodo.17407192. For a more detailed article, please reachout fc60327@alunos.fc.ul.ptMarco FerreiraAna BelchiorTeresa PinheiroGil AlvesMaria Lopeshttp://arxiv.org/abs/2601.15357v1Phantom model for intracranial pressure2026-01-21T09:28:54ZThis report presents the MOD{È}FONE project, whose objective is to develop a simplified experimental model of the cerebrospinal system in order to investigate fluid-structure interactions and physiological adaptations under altered gravity conditions, with a particular focus on microgravity. The experimental setup is based on a pulsatile hydraulic circuit reproducing systolic and diastolic dynamics, coupled with deformable elements simulating vascular compliance and a cranial compartment immersed in a fluid representing cerebrospinal fluid. This model enables the analysis of cranial and spinal pressures as well as their pulsatility. The purpose of this report is to describe the design and the results of the experimental setup.2026-01-21T09:28:54ZCélia BatononIMT - MINES ALES, Mines Saint-Étienne MSEHeimiri MonnierUPJV, CHIMEREArnaud GaubervilleIMT - MINES ALESLéna ConnessonIMT - MINES ALEShttp://arxiv.org/abs/2601.14692v1Morphology-, Noise-, and Resolution-Robust Ultrasound Elasticity Imaging with Fourier Neural Operators2026-01-21T06:08:35ZUltrasound-based elasticity imaging is a non-invasive technique for estimating tissue stiffness fields from displacement fields obtained by comparing ultrasound signals before and after compression. While recent deep learning approaches have enabled faster and more accurate elasticity estimation compared to traditional methods, several challenges remain for clinical translation. In this study, we employ finite element simulations of free-hand palpation to investigate the applicability of the Fourier neural operator (FNO). Four practical scenarios were investigated: (1) prediction across diverse lesion morphologies, (2) generalization to cases with lesion counts differing from those in the training data, (3) robustness to noise in measured displacement fields, and (4) resilience to variations in ultrasound device resolution. Across these tasks, FNO consistently outperformed baseline models such as U-Net and DeepONet in predictive accuracy and generalization, while maintaining robustness under noise and resolution changes. Validated through in silico simulations, these findings demonstrate the potential of FNO as a framework that could facilitate translation of elasticity imaging toward clinical practice.2026-01-21T06:08:35ZHeekyu KimHugon LEeMinwoo ParkSeunghwa Ryuhttp://arxiv.org/abs/2601.14654v1Dosimetry for Proton Therapy Using a β-Ga$_2$O$_3$ Metal-Semiconductor-Metal Detector with Low-Noise Amplification2026-01-21T05:00:05ZIntensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue, leading to improved patient outcomes and reduced side effects compared to traditional X-ray therapy. To ensure patient safety, each treatment plan must be experimentally validated before clinical implementation. However, current dosimetry devices face limitations in performing angled beam measurements and obtaining multi-depth assessments, both of which are essential for verifying IMPT treatment plans. In this study, the performance of a β-Ga$_2$O$_3$-based metal-semiconductor-metal (MSM) detector with a low-noise amplifier is studied and evaluated under various proton radiation doses and energy levels delivered by a MEVION S250i proton accelerator. The detector performance is also compared with that of an ionization chamber. The β-Ga$_2$O$_3$ detector exhibits a linear response with proton dose for single-spot irradiations, and its response to varying proton energies closely matches both the ion chamber data and simulated dose distributions. These findings highlight the potential of β-Ga$_2$O$_3$-based detectors as robust dosimetry devices for IMPT applications.2026-01-21T05:00:05Z7 pages, 4 figuresHunter D. EllisAjayvarman MallapillaiJared MillerImteaz RahamanBotong LiVikren SarkarKai Fuhttp://arxiv.org/abs/2601.14533v1Automatic skull-template alignment without a guidance image2026-01-20T23:07:59ZTranscranial ultrasound must overcome the significant challenge of the human skull, limiting both imaging and therapeutic applications. While high-fidelity numerical simulations can compensate for skull-induced distortions, they require precise skull templates (typically derived from Computed Tomography, CT) and spatial alignment to the patient's anatomy. Current alignment relies on concurrent Magnetic Resonance Imaging (MRI) for registration, introducing financial, logistical, and throughput barriers. To overcome these challenges, we present Manifold Optimisation for Full-Waveform Inversion (MOFI), a method to register skull templates without using a guidance image. Our method aligns the skull template by minimising the difference between simulated and observed radio-frequency acoustic data. We demonstrate that MOFI accurately recovers the position of skull templates in silico and in vitro, offering an alternative to MRI guidance-based registration. These results indicate that MOFI has the potential to be a practical alternative to MRI-guided approaches, reducing the barriers to wider clinical adoption of transcranial ultrasound.2026-01-20T23:07:59ZOscar BatesCarlos CuetoCiaran ColemanCameron A. B. SmithLluis GuaschOscar Calderon Agudohttp://arxiv.org/abs/2601.13577v1Toward Ultra-fast Treatments: Large Energy Acceptance Beam Delivery Systems and Opportunities for Proton Beam Therapy2026-01-20T04:03:14ZTreatment delivery is largely determined by capabilities of the beam delivery system (BDS), where faster delivery can have many potential benefits including improved dosimetric quality, utility, cost effectiveness, patient throughput and comfort. Despite significant developments in accelerators, delivery methodologies, dose optimisation and more, the energy layer switching time (ELST) is still a persisting limitation in existing BDS. The ELST can contribute significantly to beam delivery time (BDT) and extend treatment times, requiring compensation by optimisation planning approaches, motion mitigation strategies, or active beam modification. This fundamental constraint can be addressed by increasing the narrow energy acceptance range of conventional beamlines to minimise the ELST, enabling ultra-fast delivery. A large energy acceptance (LEA) BDS has the potential to revolutionise PBT through immediate improvements to current treatment delivery and emerging delivery modalities: the complete exploitation of PBT - and unlocking its full potential - can only be made possible with advances in beam delivery technologies. We review the abundant opportunities offered by an ultra-fast BDS: shorter treatment times, reduced motion induced dose degradation, improved effectiveness of motion management techniques, possibilities for volumetric rescanning, bidirectional delivery, further planning optimisation, and novel delivery strategies. We overview the design concepts of several LEA proposals, technology requirements, and also discuss the remaining challenges and considerations with realising a LEA BDS in practice. There are multiple avenues requiring further development and study, however the clinical potential and benefits of this enabling technology are clear: ultra-fast delivery offers both immediate and future improvements to PBT treatments.2026-01-20T04:03:14Z42 pages, 12 figuresJacinta YapAdam SteinbergHannah NormanKonrad NesterukSuzie Sheehy10.3389/fonc.2026.1791102http://arxiv.org/abs/2508.13686v2Circularly polarized light scattering imaging of a cancerous layer creeping under a healthy layer for the diagnosis of early-stage cervical cancer2026-01-20T03:48:48ZSignificance: Cervical cancer progresses through cervical intraepithelial neoplasia (CIN), which are precursor lesions of cervical cancer. In low-grade CIN, atypical cells generate inside the squamous epithelium, which causes the accuracy of cytodiagnosis for cervical cancer not to be very high. The grade of CIN can be estimated by the depth of atypical cell infiltration from the basal layer to the surface, rather than the abnormality of cells. Therefore, a non-invasive method is required to evaluate the depths of abnormal cells hidden at depths. Aim: Cancerous tissues beneath healthy tissues were experimentally identified by using circularly polarized light scattering (CiPLS). This method enabled the changes in the size of the cell nuclei within the penetration depth in tissue to be investigated. Approach: Artificial unexposed cancerous tissues were prepared that consisted of healthy/cancerous/healthy layers with various thicknesses of the topmost healthy layer and the cancerous layer. A polarization imaging camera with a quarter-wave plate was used to create distribution images of the circular polarization of the scattered light. Results: CiPLS images indicated that the thickness variation of the top healthy layer (the depth of the cancerous layer) caused significant changes in the degree of circular polarization. Conclusions: The depth of unexposed cancer lying within the optical penetration depth can be evaluated using a circular polarization imaging system based on the CiPLS method. These findings will lead to the development of a non-invasive optical diagnostic method for early-stage cervical cancer, potentially improving early detection and treatment outcomes.2025-08-19T09:39:07ZJournal of Biomedical Optics, Vol. 31, Issue 2, 027002 (February 2026)Nozomi NishizawaMahiro IshikawaMike Raj MaskeyAsato EsumiToshihide MatsumotoTakahiro Kuchimaru10.1117/1.JBO.31.2.027002http://arxiv.org/abs/2601.13393v1VAST: Vascular Flow Analysis and Segmentation for Intracranial 4D Flow MRI2026-01-19T21:00:42ZFour-dimensional (4D) Flow MRI can noninvasively measure cerebrovascular hemodynamics but remains underused clinically because current workflows rely on manual vessel segmentation and yield velocity fields sensitive to noise, artifacts, and phase aliasing. We present VAST (Vascular Flow Analysis and Segmentation), an automated, unsupervised pipeline for intracranial 4D Flow MRI that couples vessel segmentation with physics-informed velocity reconstruction. VAST derives vessel masks directly from complex 4D Flow data by iteratively fusing magnitude- and phase-based background statistics. It then reconstructs velocities via continuity-constrained phase unwrapping, outlier correction, and low-rank denoising to reduce noise and aliasing while promoting mass-consistent flow fields, with processing completing in minutes per case on a standard CPU. We validate VAST on synthetic data from an internal carotid artery aneurysm model across SNR = 2-20 and severe phase wrapping (up to five-fold), on in vitro Poiseuille flow, and on an in vivo internal carotid aneurysm dataset. In synthetic benchmarks, VAST maintains near quarter-voxel surface accuracy and reduces velocity root-mean-square error by up to fourfold under the most degraded conditions. In vitro, it segments the channel within approximately half a voxel of expert annotations and reduces velocity error by 39% (unwrapped) and 77% (aliased). In vivo, VAST closely matches expert time-of-flight masks and lowers divergence residuals by about 30%, indicating a more self-consistent intracranial flow field. By automating processing and enforcing basic flow physics, VAST helps move intracranial 4D Flow MRI toward routine quantitative use in cerebrovascular assessment.2026-01-19T21:00:42ZAbhishek SinghVitaliy L. RayzPavlos P. Vlachos