https://arxiv.org/api/HwyMBkP+Lzlxm6mCxzXQhb2sibY 2026-06-22T13:50:39Z 8985 465 15 http://arxiv.org/abs/2507.06958v2 Experimental and computational dosimetry in an integrated workflow for remote audits in Ir-192 interstitial brachytherapy: Development and pilot implementation 2026-01-27T17:20:56Z Purpose: This work describes the development and pilot implementation of a comprehensive remote dosimetry audit for Ir-192 high-dose-rate interstitial brachytherapy, integrating independent experimental and computational dosimetry within a unified workflow.Methods: A compact water-equivalent phantom accommodating two plastic catheters, ten optically stimulated luminescent dosimeters (OSLDs), and two radiochromic films was designed to enable independent point-approximating and 2D dose measurements. A user-selected treatment plan with 36 source dwell positions was generated in a clinical treatment planning system (TPS), accounting for dosimeter dose ranges. Computational audit testing was performed by analyzing DICOM-RT files and conducting Monte Carlo (MC) simulations to obtain independent 3D dose calculations for the same plan and phantom geometry. Dosimetry results were compared to TPS calculations (TG43 and a Model Based Dose Calculation Algorithm, MBDCA) using the 3D Gamma Index (GI) test, dose difference maps, and dose-volume histogram comparisons, wherever applicable. Procedures were optimized to minimize clinical workload.Results:The pilot study was completed within ten days of phantom delivery. Measurement corrections were applied when necessary using correction factors from side studies. GI criteria were adapted to the uncertainty of each dosimetry system. Excellent agreement between MBDCA and experimental or MC results was observed. Within the volume of interest, TG-43 systematically overestimated dose relative to MC results (median difference: +2.16%), attributed to missing scatter conditions and phantom material.Conclusion:Despite the labor-intensive workflow, the protocol is suitable for remote Ir-192 audits with acceptable uncertainties. Combining experimental and computational dosimetry enhances audit robustness and supports comprehensive brachytherapy auditing programs. 2025-07-09T15:40:15Z Published in Journal of Applied Clinical Medical Physics Eleftherios P Pappas Vasiliki Peppa Alexandra Drakopoulou Eleni Velissariou Zoi Thrapsanioti Georgios Kollias Efi Koutsouveli Georgia Lymperopoulou Pantelis Karaiskos http://arxiv.org/abs/2601.19962v1 Controlled drug delivery from chitosan-coated heparin-loaded nanopores anodically grown on nitinol shape-memory alloy 2026-01-27T10:51:57Z Nitinol (NiTi shape-memory alloy) is an interesting candidate in various medical applications like dental, orthopedic, and cardiovascular devices, owing to its unique mechanical behaviors and proper biocompatibility. The aim of this work is the local controlled delivery of a cardiovascular drug, heparin, loaded onto nitinol treated by electrochemical anodizing and chitosan coating. In this regard, the structure, wettability, drug release kinetics, and cell cytocompatibility of the specimens were analyzed in vitro. The two-stage anodizing process successfully developed a regular nanoporous layer of Ni-Ti-O on nitinol, which considerably decreased the sessile water contact angle and induced hydrophilicity. The application of the chitosan coatings controlled the release of heparin mainly by a diffusional mechanism, where the drug release mechanisms were evaluated by the Higuchi, first-order, zero-order, and Korsmeyer-Pepass models. Human umbilical cord endothelial cells (HUVECs) viability assay also showed the non-cytotoxicity of the samples, so that the best performance was found for the chitosan-coated samples. It is concluded that the designed drug delivery systems are promising for cardiovascular, particularly stent applications. 2026-01-27T10:51:57Z Carbohydrate polymers, 314 (2023) 120961 M. Moradi E. Salahinejad E. Sharifi L. Tayebi 10.1016/j.carbpol.2023.120961 http://arxiv.org/abs/2601.19246v1 Magnetic Resonance Simulation of Effective Transverse Relaxation (T2*) 2026-01-27T06:28:52Z Purpose: To simulate effective transverse relaxation ($T_2^*$) as a part of MR simulation. $T_2^*$ consists of reversible ($T_2^{\prime}$) and irreversible ($T_2$) components. Whereas simulations of $T_2$ are easy, $T_2^{\prime}$ is not easily simulated if only magnetizations of individual isochromats are simulated. Theory and Methods: Efficient methods for simulating $T_2^{\prime}$ were proposed. To approximate the Lorentzian function of $T_2^{\prime}$ realistically, conventional simulators require 100+ isochromats. This approximation can be avoided by utilizing a linear phase model for simulating an entire Lorentzian function directly. To represent the linear phase model, the partial derivatives of the magnetizations with respect to the frequency axis were also simulated. To accelerate the simulations with these partial derivatives, the proposed methods introduced two techniques: analytic solutions, and combined transitions. For understanding the fundamental mechanism of the proposed method, a simple one-isochromat simulation was performed. For evaluating realistic cases, several pulse sequences were simulated using two phantoms with and without $T_2^{\prime}$ simulations. Results: The one-isochromat simulation demonstrated that $T_2^{\prime}$ simulations were possible. In the realistic cases, $T_2^{\prime}$ was recovered as expected without using 100+ isochromats for each point. The computational times with $T_2^{\prime}$ simulations were only 2.0 to 2.7 times longer than those without $T_2^{\prime}$ simulations. When the above-mentioned two techniques were utilized, the analytic solutions accelerated 19 times, and the combined transitions accelerated up to 17 times. Conclusion: Both theory and results showed that the proposed methods simulated $T_2^{\prime}$ efficiently by utilizing a linear model with a Lorentzian function, analytic solutions, and combined transitions. 2026-01-27T06:28:52Z Hidenori Takeshima http://arxiv.org/abs/2601.19025v1 On the Application of Fractional Order Derivatives for Characterizing Brain White Matter Viscoelasticity 2026-01-26T23:20:36Z Conventional viscoelastic characterization of brain white matter (BWM), typically described using Prony series models, remains a largely empirical representation that is difficult to interpret physically. Growing evidence suggests that BWMviscoelasticity follows power-law behavior. Under the assumptions of linear viscoelasticity and causality, a power-law model in the frequency domain yields a fractional viscoelastic model in the time domain. A fractional viscoelastic constitutive model for the axon and extracellular matrix (ECM) is implemented via a Fortran VUMAT subroutine. A biphasic periodic finite element (FE) model of hexagonally packed representative volume elements (RVEs) of axons embedded in an ECM is constructed in Abaqus under quasi-static loading. The inverse problem of extracting homogenized material properties is solved using an optimization workflow. The model predicts that the springpot coefficient, which determines the solid-fluid behavior and, the power-law exponent, which encodes information about the underlying tissue architecture, follows a bi-logistic function along the transverse normal and shear directions. The nonlinear variation of the parameters reveals two distinct stiffening stages: a lower rate at low axon volume fractions, followed by a higher rate as increased axonal content reinforces the RVE. To our knowledge, this study is the first to propose and implement a 3D fractional viscoelastic FE model of the corpus callosum of BWM in the time domain. The thread-safe implementation of the VUMAT achieves significantly faster performance than existing approaches. The results reveal nonlinear variation in material parameters, directional dependence of BWM mechanics, and the complex interplay among microstructural elements. 2026-01-26T23:20:36Z 24 pages, 18 figures P. Pasupathy J. G. Georgiadis A. A Pelegri http://arxiv.org/abs/2507.05144v2 Clinical test cases for commissioning, QA, and benchmarking of model-based dose calculation algorithms in 192Ir HDR gynecologic tandem and ring brachytherapy 2026-01-26T17:10:44Z Purpose: To develop clinically relevant test cases for commissioning Model-Based Dose Calculation Algorithms (MBDCAs) for 192Ir High Dose Rate (HDR) gynecologic brachytherapy following the workflow proposed by the TG-186 report and the WGDCAB report 372. Acquisition and Validation Methods: Two cervical cancer intracavitary HDR brachytherapy patient models were created, using either uniformly structured regions or realistic segmentation. The computed tomography (CT) images of the models were converted to DICOM CT images via MATLAB and imported into two Treatment Planning Systems (TPSs) with MBDCA capability. The clinical segmentation was expanded to include additional organs at risk. The actual clinical treatment plan was generally maintained, with the source replaced by a generic 192Ir HDR source. Dose to medium in medium calculations were performed using the MBDCA option of each TPS, and three different Monte Carlo (MC) simulation codes. MC results agreed within statistical uncertainty, while comparisons between MBDCA and MC dose distributions highlighted both strengths and limitations of the studied MBDCAs, suggesting potential approaches to overcome the challenges. Data Format and Usage Notes: The datasets for the developed cases are available online at http://doi.org/ 10.5281/zenodo.15720996. The DICOM files include the treatment plan for each case, TPS, and the corresponding reference MC dose data. The package also contains a TPS- and case-specific user guide for commissioning the MBDCAs, and files needed to replicate the MC simulations. Potential Applications: The provided datasets and proposed methodology offer a commissioning framework for TPSs using MBDCAs, and serve as a benchmark for brachytherapy researchers using MC methods. They also facilitate intercomparisons of MBDCA performance and provide a quality assurance resource for evaluating future TPS software updates. 2025-07-07T15:55:54Z Published in Medical Physics V. Peppa M. Robitaille F. Akbari S. A. Enger R. M. Thomson F. Mourtada G. P. Fonseca http://arxiv.org/abs/2601.18843v1 Human Cardiac Measurements with Diamond Magnetometers 2026-01-26T11:42:13Z We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG). 2026-01-26T11:42:13Z Muhib Omar Magnus Benke Shaowen Zhang Jixing Zhang Michael Kuebler Pouya Sharbati Ara Rahimpour Arno Gueck Maryna Kapitonova Devyani Kadam Carlos Rene Izquierdo Geiser Jens Haller Arno Trautmann Katharina Jag-Lauber Robert Roelver Thanh-Duc Nguyen Leonardo Gizzi Michelle Schweizer Mena Abdelsayed Ingo Wickenbrock Andrew M. Edmonds Matthew Markham Peter A. Koss Oliver Schnell Ulrich G. Hofmann Tonio Ball Juergen Beck Dmitry Budker Joerg Wrachtrup Arne Wickenbrock http://arxiv.org/abs/2601.18219v1 Automated HER2 scoring with uncertainty quantification using lensfree holography and deep learning 2026-01-26T07:09:08Z Accurate assessment of human epidermal growth factor receptor 2 (HER2) expression is critical for breast cancer diagnosis, prognosis, and therapy selection; yet, most existing digital HER2 scoring methods rely on bulky and expensive optical systems. Here, we present a compact and cost-effective lensfree holography platform integrated with deep learning for automated HER2 scoring of immunohistochemically stained breast tissue sections. The system captures lensfree diffraction patterns of stained HER2 tissue sections under RGB laser illumination and acquires complex field information over a sample area of ~1,250 mm^2 at an effective throughput of ~84 mm^2 per minute. To enhance diagnostic reliability, we incorporated an uncertainty quantification strategy based on Bayesian Monte Carlo dropout, which provides autonomous uncertainty estimates for each prediction and supports reliable, robust HER2 scoring, with an overall correction rate of 30.4%. Using a blinded test set of 412 unique tissue samples, our approach achieved a testing accuracy of 84.9% for 4-class (0, 1+, 2+, 3+) HER2 classification and 94.8% for binary (0/1+ vs. 2+/3+) HER2 scoring with uncertainty quantification. Overall, this lensfree holography approach provides a practical pathway toward portable, high-throughput, and cost-effective HER2 scoring, particularly suited for resource-limited settings, where traditional digital pathology infrastructure is unavailable. 2026-01-26T07:09:08Z 23 Pages, 6 Figures, 1 Table BME Frontiers, AAAS (2026) Che-Yung Shen Xilin Yang Yuzhu Li Leon Lenk Aydogan Ozcan 10.34133/bmef.0278 http://arxiv.org/abs/2601.18082v1 Feedback-Based Quantum Control for Safe and Synergistic Drug Combination Design 2026-01-26T02:30:38Z Drug-drug interactions (DDIs) strongly affect the safety and efficacy of combination therapies. Despite the availability of large DDI databases, selecting optimal multi-drug combinations that balance safety, therapeutic benefit, and regimen size remains a challenging combinatorial optimization problem. Here, we present a quantum-control-based framework for DDI-aware drug combination optimization, in which known harmful and synergistic interactions are encoded into Ising Hamiltonians as penalties and rewards, respectively. The optimization is performed using the feedback-based quantum algorithm FALQON, a gradient-free variational approach. We study two clinically motivated tasks: the Maximum Safe Subset problem and the Synergy-Constrained Optimization problem. Numerical simulations using interaction data from Drugs.com and SYNERGxDB demonstrate efficient convergence and high-quality solutions for clinically relevant drug sets, including COVID-19 case studies. 2026-01-26T02:30:38Z 11 pages, 7 figures Mai Nguyen Phuong Nhi Lan Nguyen Tran Le Bin Ho http://arxiv.org/abs/2601.18021v1 MlPET: A Localized Neural Network Approach for Probabilistic Post-Reconstruction PET Image Analysis Using Informed Priors 2026-01-25T22:41:50Z We develop and evaluate MlPET, a fast localized machine learning approach for probabilistic PET image analysis addressing the noise-resolution trade-off in conventional reconstructions. MlPET replaces computationally demanding Markov chain Monte Carlo sampling with a localized neural network trained to estimate posterior mean voxel activity from small image neighborhoods. The method incorporates scanner-specific point spread functions, spatially correlated noise modeling, and flexible priors. Performance was evaluated on NEMA IEC phantom data from three PET systems (GE Discovery MI, Siemens Biograph Vision 600, and Quadra) under varying reconstruction settings and acquisition times. On phantom data, MlPET achieved contrast recovery coefficients consistently higher than standard PET and close to 1.0 (including 10 mm spheres), while reducing background noise and improving spatial definition. Effective pointspread function full width at half maximum decreased from approximately 2 mm in standard PET to below 1 mm with MlPET, a 2.5 fold reduction in blur. Comparable image quality was obtained at 40-80 s acquisition time with MlPET versus 900 s with conventional PET. MlPET provides an efficient approach for quantitative probabilistic post-reconstruction PET analysis. By combining informed priors with neural network speed, it achieves noise suppression and resolution enhancement without altering reconstruction algorithms. The method shows promise for improved small-lesion detectability and quantitative reliability in clinical PET imaging. Future studies will evaluate performance on patient data. 2026-01-25T22:41:50Z Thomas Mejer Hansen Nana Christensen Mikkel Vendelbo http://arxiv.org/abs/2601.19948v1 Advances in ion-doping of Ca-Mg silicate bioceramics for bone tissue engineering 2026-01-25T21:05:30Z The use of bioceramics as hard tissue substitutes is extensive due to their excellent biocompatible and osteogenic behaviors. Among various bioceramics, Ca-Mg silicates are unique from the viewpoints of osteoinductive and mechanical properties, as well as their outstanding osteoconductive and angiogenic behaviors owing to the release of Si, Ca and Mg. Despite these distinct advantages, different compositions of these bioceramics still require mechanical and biological enhancements for further applications. For this purpose, doping with some ions like F-, Sr2+, Cu2+, Eu2+, Ba+, Ce3+ and some alkali cations has been proved to be a valued approach. This review attempts to bring together areas for the performance improvement of the further researched Ca-Mg silicates (i.e., diopside, akermanite, bredigite and monticellite) and the alteration of these compositions via ion-doping. It is concluded that a correct choice of dopants incorporated at the optimal concentration makes these silicates ideal bone substitutes competing or even superior to calcium phosphates (apatites) and bioglasses which are known as the most prominent bioceramics. 2026-01-25T21:05:30Z Coordination Chemistry Reviews, 478 (2023) 215001 Ashkan Namdar Erfan Salahinejad 10.1016/j.ccr.2022.215001 http://arxiv.org/abs/2407.18709v2 Immunity to Increasing Condition Numbers of Linear Superiorization versus Linear Programming 2026-01-25T20:11:16Z Given a family of linear constraints and a linear objective function one can consider whether to apply a Linear Programming (LP) algorithm or use a Linear Superiorization (LinSup) algorithm on this data. In the LP methodology one aims at finding an optimal point, i.e., a point that fulfills the constraints and has the minimal value of the objective function over these constraints. The Linear Superiorization approach considers the same data as linear programming problems but instead of attempting to solve those with linear programming methods it employs perturbation resilient feasibility-seeking algorithms and steers them toward a feasible point with reduced (not necessarily minimal) objective function value. This aim of the superiorization method (SM) is less demanding than aiming to reach full-fledged constrained optimality and it places more importance on reaching feasibility than on reaching optimality. Previous studies (e. g. [12]) compared LP and LinSup in terms of their respective outputs and the resources they use. This paper is a follow-up analysis of [12], where we investigate classical LP approaches and LinSup in terms of their sensitivity to condition numbers of the system of linear constraints. Condition numbers are a measure for the impact of deviations in the input data on the output of a problem and, in particular, they describe the factor of error propagation when given wrong or erroneous data. Therefore, the ability of LP and LinSup to cope with increased condition numbers, thus with ill-posed problems, is an important matter to consider which was not studied until now. We investigate experimentally the advantages and disadvantages of both LP and LinSup on exemplary problems of linear programming with multiple condition numbers and different problem dimensions. 2024-07-26T12:49:52Z 22 pages, 6 figures Jan Schröder Yair Censor Philipp Süss Karl-Heinz Küfer http://arxiv.org/abs/2505.12494v3 SMURF: Scalable method for unsupervised reconstruction of flow in 4D flow MRI 2026-01-25T14:50:48Z We introduce SMURF, a scalable and unsupervised machine learning method for simultaneously segmenting vascular geometries and reconstructing velocity fields from 4D flow MRI data. SMURF models geometry and velocity fields using multilayer perceptron-based functions incorporating Fourier feature embeddings and random weight factorization to accelerate convergence. A measurement model connects these fields to the observed image magnitude and phase data. Maximum likelihood estimation and subsampling enable SMURF to process high-dimensional datasets efficiently. Evaluations on synthetic, in vitro, and in vivo datasets demonstrate SMURF's performance. On synthetic internal carotid artery aneurysm data derived from CFD, SMURF achieves a quarter-voxel segmentation accuracy across noise levels of up to 50%, outperforming the state-of-the-art segmentation method by up to double the accuracy. In an in vitro experiment on Poiseuille flow, SMURF reduces velocity reconstruction RMSE by approximately 34% compared to raw measurements. In in vivo internal carotid artery aneurysm data, SMURF attains nearly half-voxel segmentation accuracy relative to expert annotations and decreases median velocity divergence residuals by about 31%, with a 27% reduction in the interquartile range. These results indicate that SMURF is robust to noise, preserves flow structure, and identifies patient-specific morphological features. SMURF advances 4D flow MRI accuracy, potentially enhancing the diagnostic utility of 4D flow MRI in clinical applications. 2025-05-18T16:37:14Z Atharva Hans Abhishek Singh Pavlos Vlachos Ilias Bilionis http://arxiv.org/abs/2601.18826v1 OCTA-Based Biomarker Characterization in nAMD 2026-01-25T11:16:07Z We aim to enhance ophthalmologists' decision-making when diagnosing the Neovascular Age-Related Macular Degeneration (nAMD). We developed three tools to analyze Optical Coherence Tomography Angiography images: (1) extracting biomarkers such as mCNV area and vessel density using image processing; (2) generating a 3D visualization of the neovascularization for a better view of the affected regions; and (3) applying an ensemble of three white box machine learning algorithms (decision tree, support vector machines and DL-Learner) for nAMD diagnosis. The learned expressions reached 100% accuracy for the training data and 68% accuracy in testing. The main advantage is that all the learned models white-box, which ensures explainability and transparency, allowing clinicians to better understand the decision-making process. 2026-01-25T11:16:07Z 2025 IEEE 6th International Conference on Image Processing, Applications and Systems (IPAS) MAria Simona Tivadar Ioana Damian Adrian Groza Simona Delia Nicoara 10.1109/IPAS63548.2025.10924557 http://arxiv.org/abs/2601.17750v1 Multi-Criteria Inverse Robustness in Radiotherapy Planning Using Semidefinite Programming 2026-01-25T08:47:20Z Radiotherapy planning naturally leads to a multi-criteria optimization problem which is subject to different sources of uncertainty. In order to find the desired treatment plan, a decision maker must balance these objectives as well as the level of robustness towards uncertainty against each other. This paper showcases a quantitative approach to do so, which combines the theoretical model with the ability to deal with practical challenges. To this end, the uncertainty, which can be expressed via the so-called dose-influence matrix, is modelled using interval matrices. We use inverse robustness to introduce an additional objective, which aims to maximize the volume of the uncertainty set. A multi-criteria approach allows to handle the uncertainty while keeping appropriate values of the other objective functions. We solve the resulting quadratically constrained quadratic optimization problem (QCQP) by first relaxing it to a convex semidefinite problem (SDP) and then reconstructing optimal solutions of the QCQP from solutions of the SDP. 2026-01-25T08:47:20Z 23 pages, 3 figures Jan Schröeder Yair Censor Philipp Süss Karl-Heinz Küfer http://arxiv.org/abs/2510.11271v2 An AI dose engine for fast carbon ion treatment planning 2026-01-24T16:27:23Z Monte Carlo (MC) simulations provide gold-standard accuracy for carbon ion therapy dose calculations but are computationally intensive. Analytical pencil beam algorithms offer speed but reduced accuracy in heterogeneous tissues. We developed the first AI-based dose engine capable of predicting absorbed dose, the alpha and beta parameters for relative biological effectiveness (RBE)- weighted optimisation in carbon ion therapy, delivering MC-level accuracy with drastically reduced computation time. We extended the transformer-based DoTA model to predict absorbed dose (C-DoTA-d), alpha (C-DoTA-alpha), and beta (C-DoTA-beta), introducing a cross-attention mechanism for alpha and beta to combine dose and energy inputs. The training dataset consisted of ~70,000 pencil beams from 187 head-and-neck patients, with ground-truth values obtained using the GPU-accelerated MC toolkit FRED. Performance was evaluated on an independent test set using gamma pass rate (1%/1 mm), depth-dose, and isodose contour Dice coefficients. MC dropout-based uncertainty analysis was performed. Median gamma pass rates exceeded 98% for all predictions (99.76% for dose, 99.14% for alpha, and 98.74% for beta), with minima above 85% in the most heterogeneous anatomies. The Dice coefficient was 0.95 for 1% isodose contours, with slightly reduced agreement in high-gradient regions. Compared to MC FRED, inference was over 400x faster (0.032 s vs. 14 s per pencil beam) while maintaining accuracy. Uncertainty analysis showed high stability, with mean standard deviations below 0.5% for all models. C-DoTA achieves MC-quality predictions of absorbed dose and RBE model parameters in ~30 milliseconds per beam. Its speed and accuracy support online adaptive planning, paving the way for more effective carbon ion therapy workflows. Future work will expand to additional anatomical sites, beam geometries, and clinical beamlines. 2025-10-13T11:05:30Z Anastasiia Quarz Angelica De Gregorio Gaia Franciosini Angelo Schiavi Zoltán Perkó Lennart Volz Christoph Hoog Antink Vincenzo Patera Marco Durante Christian Graeff