https://arxiv.org/api/0zF8xMkxagXzOcI2je5xOwV9zfk 2026-06-22T12:32:32Z 8985 450 15 http://arxiv.org/abs/2508.12827v2 Towards a better understanding of abdominal wall biomechanics: in vivo relationship between dynamic intra-abdominal pressure and magnetic resonance imaging measurements 2026-01-30T10:29:08Z Background In vivo mechanical behaviour of the abdominal wall has been poorly characterised and important details are missing regarding the occurrence and post-operative recurrence rate of hernias which can be as high as 30 %. This study aimed to assess the correlation between abdominal wall displacement and intra-abdominal pressure, as well as abdominal compliance. Methods Eighteen healthy participants performed audio-guided passive (breathing) and active (coughing, Valsalva maneuver) exercises. Axial dynamic changes of abdominal muscles and visceral area were measured using MRI, and intra-abdominal pressure with ingested pressure sensor. Findings Correlations between abdominal wall displacement and intra-abdominal pressure were specific to participant, exercise, and varying between rectus abdominis and lateral muscles. Strong correlations were found between rectus abdominis displacement and intra-abdominal pressure during breathing (r = 0.92 $\pm$ 0.06), as well as lateral muscles displacement with intra-abdominal pressure during coughing and Valsalva maneuver (r = --0.98 $\pm$ 0.03 and -- 0.94 $\pm$ 0.05 respectively). The abdominal pseudo-compliance varied greatly among participants during muscular contraction, the coefficient of variation reaching up to 70 %. Interpretation The combination of intra-abdominal pressure and dynamic MRI measurements enables the identification of participant-specific behaviour pattern. Intra-abdominal pressure and abdominal wall dynamic undergo consistent and predictable interactions. However, this relationship is subject-specific and may not be extrapolated to other individuals. Therefore, both intra-abdominal pressure and abdominal wall motion must be measured in the same participant in order to accurately characterise the abdominal wall behaviour. These results are of great importance for mesh design, surgical decision-making, and personalised healthcare. 2025-08-18T11:12:03Z Clinical Biomechanics, 2024, 121, pp.106396 Victoria Joppin LBA UMR T24, CRMBM Arthur Jourdan LBA UMR T24 David Bendahan CRMBM Andréa Soucasse LBA UMR T24 Maxime Guye CRMBM, TIMONE Catherine Masson LBA UMR T24 Thierry Bège LBA UMR T24 http://arxiv.org/abs/2601.22793v1 Fast Eikonal Phase Retrieval for High-Throughput Beamlines 2026-01-30T10:15:23Z We introduce a fast Eikonal Phase Retrieval (EPR) formulation that accelerates eikonal phase retrieval by more than two orders of magnitude while retaining controlled accuracy. The method is derived from a second-order asymptotic expansion in the propagation distance $L$ and complemented by the leading Wentzel--Kramers--Brillouin (WKB) wave-optics correction, yielding an efficient iterative correction scheme preconditioned by FFT-diagonal, energy-dependent inverse operators (Paganin-type filters). To ensure robustness across practical experimental regimes, we combine two complementary solvers: (i) a local $O(L^2)$ closure that is accurate when eikonal shifts remain sub-pixel, and (ii) a non-local formulation for multi-pixel shifts, in which intensity is propagated through an explicit eikonal ray mapping using a mass-conserving bilinear redisribution on the detector grid, and detector residuals are transferred back to the object grid by the corresponding adjoint (transpose), implemented as bilinear interpolation, before applying an approximate FFT-diagonal preconditioner to accelerate convergence. The same framework supports polychromatic data through a compact spectral discretisation, allowing energy-dependent transport and inversion while keeping the iteration GPU/FFT efficient. Overall, this unified approach enables accurate and computationally efficient phase retrieval across propagation conditions relevant to high-throughput PPC-$μ$CT experiments. 2026-01-30T10:15:23Z Alessandro Mirone Theresa Urban Joseph Brunet Claire L. Walsh Peter D. Lee Paul Tafforeau http://arxiv.org/abs/2601.22743v1 Combining quasi-static and high frequency experiments for the viscoelastic characterization of brain tissue 2026-01-30T09:23:03Z Mechanical models of brain tissue are a beneficial tool to simulate neurosurgical interventions, disease progression, or brain development. However, the accuracy and predictive capacity of such a model relies on a precise experimental characterization of the tissue's mechanical behavior. Such a characterization is yet limited by inconsistent or contradictory experimental responses reported in the literature, particularly when measurements are performed in different time or length scales. Although brain tissue has been extensively investigated in previous studies, the combination of experimental findings from different scales has received limited attention. In this study, we combine ex vivo mechanical responses of porcine brain tissue obtained at different time scales in a mechanical model. We investigated the mechanical behavior of three different brain regions in the quasi-static domain with multi-modal large strain rheometer measurements and at high frequencies with magnetic resonance elastography (MRE). A comparative analysis of the mechanical parameters obtained from both experimental techniques demonstrated consistent regional variations in the viscoelastic behavior across the two domains. However, the mechanical behavior changes from a higher elasticity in the quasi-static and low frequency domain to a dominating viscosity at high frequencies. Based on the quasi-static and the high frequency behavior, we calibrated a fractional Kelvin-Voigt model and consequently unified the two responses in a single mechanical model to obtain a comprehensive characterization of the tissue's mechanical behavior. 2026-01-30T09:23:03Z Laura Ruhland Nina Reiter Silvia Budday Kai Willner 10.1016/j.jmbbm.2026.107462 http://arxiv.org/abs/2510.21054v4 Predictive Dosimetry in PSMA-Targeted Radiopharmaceutical Therapies: A PBPK Modeling and Machine Learning Study 2026-01-29T23:04:02Z Predictive dosimetry is central to enabling personalized radiopharmaceutical therapy (RPT), particularly in prostate specific membrane antigen (PSMA) targeted theranostics. In this work, we develop a three layer computational framework that integrates physiologically based pharmacokinetic (PBPK) modeling with machine learning (ML) to predict both physical (AUC, absorbed dose) and biological (BED, EQD2) dosimetric endpoints in tumors and major organs. In the first layer, we generated 640 virtual patients using PBPK simulations of F-18, Ga-68, and Cu-64 labeled PSMA PET tracers paired with Lu-177 PSMA therapy, producing 15360 tumor and organ time activity curves (TACs) under realistic biological variability and PET-like noise. In the second layer, TACs were transformed into quantitative kinetic features and mapped to physical and biological dose metrics. In the third layer, ML models (Random Forest, Extra Trees, Ridge, Gradient Boosting, and XGBoost) were trained to predict RPT doses from PET derived features, with performance evaluated using mean absolute percentage error (MAPE) and R2. Cu-64 PSMA-617 based PET yielded the most robust predictions, achieving tumor dose MAPE as low as 8 percent and 10 to 20 percent for normal organs, while F-18 DCFPyL showed volume dependent performance and Ga-68 PSMA-11 exhibited higher variability. SHAP analysis revealed that peak uptake, clearance, and early kinetic features dominated predictive performance across organs and endpoints. This PBPK ML framework enables scalable, physiology informed predictive dosimetry and provides a foundation for trial design and patient specific treatment planning in PSMA targeted RPT. These results demonstrate that pre therapy PET can serve as a reliable surrogate for post therapy dosimetry, enabling scalable personalization of PSMA targeted RPT. 2025-10-23T23:59:17Z Hamid Abdollahi Department of Radiology, University of British Columbia, Vancouver, Canada Department of Basic and Translation Research, BC Cancer Research institute, Vancouver, Canada James Fowler Department of Basic and Translation Research, BC Cancer Research institute, Vancouver, Canada Department of Physics & Astronomy, University of British Columbia, Vancouver, Canada Carlos Uribe Department of Basic and Translation Research, BC Cancer Research institute, Vancouver, Canada Department of Molecular Imaging and Therapy, BC Cancer, Vancouver, Canada Arman Rahmim Department of Radiology, University of British Columbia, Vancouver, Canada Department of Basic and Translation Research, BC Cancer Research institute, Vancouver, Canada Department of Physics & Astronomy, University of British Columbia, Vancouver, Canada http://arxiv.org/abs/2601.22391v1 Body Fat, Skin Tone, and the Accuracy of Smartwatch Caloric Expenditure Estimates 2026-01-29T22:58:38Z Smartwatches are widely used to estimate caloric expenditure for weight management, clinical decision making, and public health monitoring. These devices combine photoplethysmography, accelerometry, and proprietary algorithms. However, prior studies report substantial error, and the influence of moderators such as skin tone and body fat percentage (BF) remains underexamined. This study tested whether smartwatch brand, BF, and Fitzpatrick skin type (III to V) predict caloric expenditure error relative to indirect calorimetry. Fifty eight Hispanic adults completed a single laboratory visit including a ten minute recumbent cycling protocol with alternating two minute moderate and vigorous intensity intervals, bracketed by rest and recovery. Participants wore four consumer devices: Apple Watch Series 8, Fitbit Sense 2, Samsung Galaxy Watch 5, and Garmin Forerunner 955. Energy expenditure was measured using a COSMED K5 metabolic system. After device specific data quality filtering, valid participant device pairings ranged from 44 to 52 per brand. One sample tests showed significant mean bias for three devices: Apple, Garmin, and Samsung. Fitbit showed no significant overall bias, although this depended on device specific outlier removal. Mean bias varied by brand, with Garmin and Samsung showing the largest overestimations. Mixed effects models revealed significant effects of device and BF, as well as a device by BF interaction, with physical activity energy expenditure error increasing as adiposity increased. Overall, common smartwatches substantially misestimate caloric expenditure compared with indirect calorimetry. Error varies by brand and worsens with higher body fat, highlighting limitations of current consumer wearables and the need for improved accuracy across diverse body types. 2026-01-29T22:58:38Z Jason Kostrna Ekaterina Oparina Andres J. Rodriguez JunZhu Pei Ajmal Ajmal Cristina Palacios Jessica C. Ramella-Roman http://arxiv.org/abs/2601.22377v1 PPG-Based Heart Rate Accuracy in Diverse Populations: Investigating Inequities Across Body Composition and Skin Tones 2026-01-29T22:41:37Z Wearable devices are widely used for heart rate (HR) monitoring, yet their accuracy across diverse body compositions and skin tones remains uncertain. This study evaluated four wrist worn devices (Apple, Fitbit, Samsung, Garmin) in 58 Hispanic adults with Fitzpatrick skin types III to V during a cycling protocol alternating moderate (0.64 to 0.76 HRmax) and vigorous (0.77 to 0.95 HRmax) intensities. Criterion HR was obtained using a Polar H10 ECG, and accuracy was assessed using mean absolute error, mean absolute percentage error (MAPE), bias, and intraclass correlation coefficients. All devices showed significant deviation from criterion measures. Apple and Garmin demonstrated the lowest error, whereas Fitbit and Samsung exhibited greater inaccuracies. Higher BMI and darker skin tones were associated with increased MAPE. These biases disproportionately affect higher risk populations, underscoring the need for improved algorithms to ensure equitable health monitoring. 2026-01-29T22:41:37Z Kostrna Jason Oparina Ekaterina Palacios Cristina Rodriguez Andres J Pei JunZhu Ajmal Ajmal Ramella-Roman Jessica C http://arxiv.org/abs/2601.22059v1 AIRPET: Virtual Positron Emission Tomography 2026-01-29T17:58:27Z Positron Emission Tomography (PET) is a powerful medical imaging technique, but the design and evaluation of new PET scanner technologies present significant challenges. The process is typically divided into three major stages: 1. detector design and simulation, 2. image reconstruction, and 3. image interpretation. Each of these stages requires significant expertise, making it difficult for individuals or small teams to manage all three at once. AIRPET (AI-driven Revolution in Positron Emission Tomography) is a web-based platform designed to address this challenge by integrating all phases of PET design into a single, accessible, and AI-assisted workflow. AIRPET provides an interface to large language models (LLMs) for assisted geometry creation and an interface for basic PET image reconstruction with the potential for further expansion. Here we introduce AIRPET and outline its current functionality and proposed additions. 2026-01-29T17:58:27Z 6 pages, 3 figures J. Renner J. J. Gómez-Cadenas R. Soleti http://arxiv.org/abs/2312.15462v2 DeLTA-BIT: an open-source probabilistic tractography-based deep learning framework for thalamic targeting in functional neurological disorders 2026-01-29T12:19:02Z In the last years in-vivo tractography has assumed an important role in neurosciences, for both research and clinical applications such as non-invasive investigation of brain connectivity and presurgical planning in neurosurgery. In more recent years there has been a growing interest in the applications of diffusion tractography for target identification in functional neurological disorders for an increasingly tailored approach. The growing diffusion of well-established neurosurgical procedures, such as deep brain stimulation or trans-cranial Magnetic Resonance-guided Focused Ultrasound, favored this trend. Tractography can indeed provide more accurate, patient-specific, information about the targeted region if compared to stereotactic atlases. On the other hand, this tractography-based approach is not very physician-friendly, and its heavily time consuming since it needs several hours for Magnetic Resonance Imaging data processing. In this study we propose a novel open-source deep learning framework called DeLTA-BIT (acronym of Deep-learning Local TrActography for BraIn Targeting) for fast target predictions, based on probabilistic tractography. The proposed framework exploits a convolutional neural network (CNN) to predict the location of the Ventral Intermediate Nucleus of the thalamus (VIM). The CNN was trained on the Human Connectome Project (HCP) dataset. The model capability in predicting the VIM location was tested both on the HCP (internal validation) and clinical data (external validation). Results from the internal validation have shown good capability in predicting the VIM region (mean DSC = 0.62+- 0.15, mean sDSC=0.76+- 0.17) by using just T1 images as input, in a time scale of fraction of second per subject. As for the clinical data, results have been compared with an atlas-based method demonstrating similar performance, but within a significantly shorter timeframe. 2023-12-24T11:43:36Z Mattia Romeo Cesare Gagliardo Grazia Cottone Giorgio Collura Enrico Maggio Claudio Runfola Eleonora Bruno Maria Cristina D'Oca Massimo Midiri Francesca Lizzi Ian Postuma Marco D'Amelio Alessandro Lascialfari Alessandra Retico Maurizio Marrale http://arxiv.org/abs/2602.00146v1 Effects of PLGA coating on biological and mechanical behaviors of tissue engineering scaffolds 2026-01-29T08:30:16Z Scaffolds have a key role in the clinical success of tissue engineering for the regeneration of damaged tissues. Their bio-performance is often described as the extent to which they can provide an extracellular matrix-like environment for cells embedded where their function and growth can effectively continue. For this purpose, tissue engineering scaffolds should exhibit biodegradability, biocompatibility, bioactivity, delivery, and mechanical performance. The use of polymer coatings, especially poly(lactic-co-glycolic acid) (PLGA), on tissue engineering scaffolds has been found to be one of the most effective methods to improve the scaffold properties. This paper reviews the techniques used to coat tissue engineering scaffolds with PLGA and its effects on the mechanical characteristics, biodegradability, biocompatibility, Molecular delivery, and osteointegration of the scaffolds. It is concluded that apart from apatite-formation ability, all bio-functionalities can be tuned through PLGA coatings. This reflects the great potential of this modification approach to be used in tissue regeneration and therapeutic delivery applications. 2026-01-29T08:30:16Z Progress in Organic Coatings, 176 (2023) 107406 A. M. Maadani F. Davoodian E. Salahinejad 10.1016/j.porgcoat.2023.107406 http://arxiv.org/abs/2602.07003v1 Time-Resolved Multi-Spectral X-ray Computed Tomography of Cryoprotectant Diffusion Into Biomimetic Material 2026-01-29T04:59:02Z Cryopreservation via vitrification requires loading cryoprotective cocktails. Insufficient loading may lead to freezing, precluding successful recovery; overloading is toxic. Yet, existing in situ measurements of cryoprotectant permeation remain largely unvalidated and do not resolve individual cryoprotectant concentrations. We introduce multi-spectral X-ray computed tomography (MSCT) to noninvasively quantify the spatiotemporal distribution of cryoprotectants diffusing into a tissue mimicking phantom. A developed photon-energy bin selection algorithm achieves sensitivity to low contrast cryoprotectants without contrast agents or fluorescence edges. The technique is validated with a dimethyl sulfoxide, glycerol, and water solution, resolving cryoprotectant volume fractions to within 5% accuracy. We observe heterogeneous diffusion of the cryoprotectants into the tissue mimicking hydrogel, a phenomenon not observable with conventional techniques. MSCT improves upon existing X ray CT methods because it is not underdetermined for multicomponent solutions and does not implicitly assume homogeneous diffusion. These advancements enable the systematic development of cryoprotectant loading protocols and provide diagnostics to assess vitrifiability before cryopreservation. 2026-01-29T04:59:02Z 30 pages, 10 figures Alaa M. Ali Jason T. Parker Anthony N. Consiglio Brooke S. Chang Linnea Warburton Boris Rubinsky Simo A. Mäkiharju http://arxiv.org/abs/2601.20457v1 TIARA: a fast gamma-ray detector for range monitoring in Proton Therapy 2026-01-28T10:31:26Z We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF$_2$ crystal (2 $\times$ 1.5 $\times$ 1.5 cm$^{3}$) coupled to a 2 $\times$ 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF$_2$ allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2$σ$ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of $\mathbf{\sim}$10$\mathbf{^{7}}$ protons. 2026-01-28T10:31:26Z A. André M. Pinson C. Hoarau Y. Boursier M. Dupont L. Gallin Martel M. -L. Gallin Martel A. Garnier J. Hérault J. -P. Hofverberg P. Kavrigin C. Morel J. -F. Muraz M. Pullia S. Savazzi D. Maneval S. Marcatili http://arxiv.org/abs/2510.18387v2 Quantification of dual-state 5-ALA-induced PpIX fluorescence: Methodology and validation in tissue-mimicking phantoms 2026-01-28T10:22:31Z Quantification of protoporphyrin IX (PpIX) fluorescence in human brain tumours has the potential to significantly improve patient outcomes in neuro-oncology, but represents a formidable imaging challenge. Protoporphyrin is a biological molecule which interacts with the tissue micro-environment to form two photochemical states in glioma. Each exhibits markedly different quantum efficiencies, with distinct but overlapping emission spectra that also overlap with tissue autofluorescence. Fluorescence emission is known to be distorted by the intrinsic optical properties of tissue, coupled with marked intra-tumoural heterogeneity as a hallmark of glioma tumours. Existing quantitative fluorescence systems are developed and validated using simplified phantoms that do not simultaneously mimic the complex interactions between fluorophores and tissue optical properties or micro-environment. Consequently, existing systems risk introducing systematic errors into PpIX quantification when used in tissue. In this work, we introduce a novel pipeline for quantification of PpIX in glioma, which robustly differentiates both emission states from background autofluorescence without reliance on a priori spectral information, and accounts for variations in their quantum efficiency. Unmixed PpIX emission forms are then corrected for wavelength-dependent optical distortions and weighted for accurate quantification. Significantly, this pipeline is developed and validated using novel tissue-mimicking phantoms replicating the optical properties of glioma tissues and photochemical variability of PpIX fluorescence in glioma. Our workflow achieves strong correlation with ground-truth PpIX concentrations (R2 = 0.918+-0.002), demonstrating its potential for robust, quantitative PpIX fluorescence imaging in clinical settings. 2025-10-21T08:07:14Z Silvère Ségaud Charlie Budd Matthew Elliot Graeme Stasiuk Jonathan Shapey Yijing Xie Tom Vercauteren 10.1088/1361-6560/ae45e6 http://arxiv.org/abs/2501.10764v2 Energy-Threshold Bias Calculator: A Physics-Model Based Adaptive Correction Scheme for Photon-Counting CT 2026-01-28T10:07:20Z Photon-counting detector based computed tomography (PCCT) has greatly advanced in recent years. However, spectral inconsistency, referring to inter-pixel variations in detected counts per energy bin, can easily leads to ring or band artifacts and inaccuracies in CT reconstructed images. This work proposes a novel physics-model based method to correct for spectral inconsistency by modeling it through two terms: (1) a fixed spectral skew term (energy threshold-independent filtration function) determined at a given energy threshold, and (2) a variable energy-threshold bias term that can be directly calculated by using our spectral model as the threshold changes. After the two terms being computed out in the calibration stage, they will be incorporated into our spectral model to adaptively generate the spectral correction vectors as well as the material decomposition vectors if needed, pixel-by-pixel for PCCT projection data. Using a minimum set of parameters with explicit physics meaning, such an energy-threshold bias calculator (ETB-Cal) has advantages of computational efficiency, robustness in implementation, and convenience with no need of X-ray fluorescence materials in calibration. To validate our method, both numerical simulations and physical experiments using multiple phantoms were carried out on a tabletop PCCT system, with preliminary results showing a significant reduction in non-uniformity, from 29.3 to 5.8 HU for Gammex multi-energy phantom versus no correction (comparatively, 8.3 HU was achieved by a polynomial-involving model-based approach with no explicit modeling and calculating of energy threshold bias but more calibration data required), and from 27.9 to 3.2 HU for the Kyoto head phantom. 2025-01-18T13:32:17Z 18 pages, 14 figures IEEE Trans. Med. Imaging, early access, 2026 Yuting Chen Yuxiang Xing Li Zhang Zhi Deng Hewei Gao 10.1109/TMI.2026.3654612 http://arxiv.org/abs/2601.20291v1 A Learning-based Framework for Spatial Impulse Response Compensation in 3D Photoacoustic Computed Tomography 2026-01-28T06:18:20Z Photoacoustic computed tomography (PACT) is a promising imaging modality that combines the advantages of optical contrast with ultrasound detection. Utilizing ultrasound transducers with larger surface areas can improve detection sensitivity. However, when computationally efficient analytic reconstruction methods that neglect the spatial impulse responses (SIRs) of the transducer are employed, the spatial resolution of the reconstructed images will be compromised. Although optimization-based reconstruction methods can explicitly account for SIR effects, their computational cost is generally high, particularly in three-dimensional (3D) applications. To address the need for accurate but rapid 3D PACT image reconstruction, this study presents a framework for establishing a learned SIR compensation method that operates in the data domain. The learned compensation method maps SIR-corrupted PACT measurement data to compensated data that would have been recorded by idealized point-like transducers. Subsequently, the compensated data can be used with a computationally efficient reconstruction method that neglects SIR effects. Two variants of the learned compensation model are investigated that employ a U-Net model and a specifically designed, physics-inspired model, referred to as Deconv-Net. A fast and analytical training data generation procedure is also a component of the presented framework. The framework is rigorously validated in virtual imaging studies, demonstrating resolution improvement and robustness to noise variations, object complexity, and sound speed heterogeneity. When applied to in-vivo breast imaging data, the learned compensation models revealed fine structures that had been obscured by SIR-induced artifacts. To our knowledge, this is the first demonstration of learned SIR compensation in 3D PACT imaging. 2026-01-28T06:18:20Z Submitted to IEEE TMI Kaiyi Yang Seonyeong Park Gangwon Jeong Hsuan-Kai Huang Alexander A. Oraevsky Umberto Villa Mark A. Anastasio http://arxiv.org/abs/2601.19994v1 A Practical Computational Hemolysis Model Incorporating Biophysical Properties of the Red Blood Cell Membrane 2026-01-27T19:01:09Z Purpose: Hemolysis is a key issue in the design of blood-handling medical devices. Computational prediction of this phenomenon is challenging due to the complex multiscale nature of blood. As a result, conventional approaches often fail to predict hemolysis accurately, commonly showing deviations of multiple orders of magnitude compared to experimental data. More accurate models are typically computationally expensive and thus impractical for real-world applications. This work aims to fill this gap by presenting accurate yet simple and efficient computational hemolysis models. Methods: Hemolysis modeling relies on two key components: a red blood cell model and a hemoglobin release model. In this work, we compare three red blood cell models: a common stress-based model (Bludszuweit), a simple strain-based model based on the Kelvin-Voigt constitutive law, and a more complex tensor-based model (TTM). Further, we compare two hemoglobin release models: the widely used power-law approach and a biophysical pore formation model. Results: We evaluate these models in two benchmark cases: the FDA blood pump and the FDA nozzle. In both benchmarks, the simple strain-based model combined with the pore formation model achieves absolute predictions of hemolysis within the standard deviation of experimental measurements. In contrast, stress-based power law models deviate by several orders of magnitude. Conclusion: The strain-based pore modeling approach takes into account the biophysical properties of red blood cell membranes, in particular their viscoelastic deformation behavior and hemoglobin release through membrane pores. This leads to significantly improved hemolysis predictions in a framework that can easily be integrated into common CFD workflows. 2026-01-27T19:01:09Z 34 pages, 7 figures Nico Dirkes Marek Behr