https://arxiv.org/api/ncdenttO9w3au6na1pwQbT18cG82026-06-22T10:09:42Z898542015http://arxiv.org/abs/2602.07162v1High-fidelity 3D multi-slab diffusion MRI using Slab-shifting for Harmonized 3D Acquisition and Reconstruction with Profile Encoding Networks (SHARPEN)2026-02-06T20:03:25ZThree-dimensional (3D) multi-slab imaging is a promising approach for high-resolution in vivo diffusion MRI (dMRI) due to its compatibility with short TR (1-2 s), providing optimal signal-to-noise ratio (SNR) efficiency. A major challenge, however, is slab boundary artifacts arising from non-ideal slab-selective RF excitation. Non-rectangular slab profiles reduce signal intensity at slab boundaries, while profile overlap across adjacent slabs introduces inter-slab crosstalk, where repeated excitation shortens the local TR and limits T1 recovery. To mitigate slab boundary artifacts without increasing scan time, we build on slab profile encoding and propose Slab-shifting for Harmonized 3D Acquisition and Reconstruction with Profile Encoding Networks (SHARPEN). For different diffusion directions, SHARPEN applies inter-volume field-of-view shifts along the slice direction to provide complementary slab profile encoding without prolonging acquisition. Slab profiles are estimated using a lightweight self-supervised neural network that exploits consistency across shifted acquisitions and known physical properties of slab profiles and diffusion images, and corrected images are reconstructed accordingly. SHARPEN was validated using simulated and prospectively acquired high-resolution in vivo data and demonstrates accurate slab profile estimation and robust boundary artifact correction, even in the presence of inter-volume motion. SHARPEN does not require high-quality reference training data and supports subject-specific training. Its efficient GPU-based implementation delivers faster and more accurate correction than NPEN, yielding slice-wise quantitative profiles that closely match those from reference 2D acquisitions. SHARPEN enables high-quality dMRI at 0.7 mm isotropic resolution on a 3T clinical scanner, highlighting its potential to advance submillimeter dMRI for neuroscience research.2026-02-06T20:03:25Z26 pages, 11 figures + supplementary infoZiyu LiKarla L. MillerWenchuan Wuhttp://arxiv.org/abs/2504.19175v2A tissue-informed deep learning-based method for positron range correction in preclinical 68Ga PET imaging2026-02-06T09:47:17ZPositron range (PR) limits spatial resolution and quantitative accuracy in PET imaging, particularly for high-energy positron-emitting radionuclides like 68Ga. We propose a deep learning method using 3D residual encoder-decoder convolutional neural networks (3D RED-CNNs), incorporating tissue-dependent anatomical information through a u-map-dependent loss function. Models were trained with realistic simulations and, using initial PET and CT data, generated positron range corrected images. We validated the models in simulations and real acquisitions. Three 3D RED-CNN architectures, Single-channel, Two-channel, and DualEncoder, were trained on simulated PET datasets and evaluated on synthetic and real PET acquisitions from 68Ga-FH and 68Ga-PSMA-617 mouse studies. Performance was compared to a standard Richardson-Lucy-based positron range correction (RL-PRC) method using metrics such as mean absolute error (MAE), structural similarity index (SSIM), contrast recovery (CR), and contrast-to-noise ratio (CNR). CNN-based methods achieved up to 19 percent SSIM improvement and 13 percent MAE reduction compared to RL-PRC. The Two-Channel model achieved the highest CR and CNR, recovering lung activity with 97 percent agreement to ground truth versus 77 percent for RL-PRC. Noise levels remained stable for CNN models (approximately 5.9 percent), while RL-PRC increased noise by 5.8 percent. In preclinical acquisitions, the Two-Channel model achieved the highest CNR across tissues while maintaining the lowest noise level (9.6 percent). Although no ground truth was available for real data, tumor delineation and spillover artifacts improved with the Two-Channel model. These findings highlight the potential of CNN-based PRC to enhance quantitative PET imaging, particularly for 68Ga. Future work will improve model generalization through domain adaptation and hybrid training strategies.2025-04-27T09:34:25ZSubmitted to EJNMMI PhysicsNerea Encina-BarandaNuclear Physics Group, EMFTEL and IPARCOS, University Complutense of MadridInstituto de Investigación Sanitaria, Hospital Clínico San CarlosRobert J. Paneque-YuntaNuclear Physics Group, EMFTEL and IPARCOS, University Complutense of MadridInstituto de Investigación Sanitaria, Hospital Clínico San CarlosJavier Lopez-RodriguezNuclear Physics Group, EMFTEL and IPARCOS, University Complutense of MadridInstituto de Investigación Sanitaria, Hospital Clínico San CarlosEdwin C. PrattMolecular Pharmacology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USADepartment of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USADepartment of Pharmacology, Weill Cornell Graduate School, 1300 York Avenue, New York, 10065, New York, USATrong Nghia NguyenMolecular Pharmacology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USADepartment of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USADepartment of Pharmacology, Weill Cornell Graduate School, 1300 York Avenue, New York, 10065, New York, USAJan GrimmMolecular Pharmacology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USADepartment of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USADepartment of Pharmacology, Weill Cornell Graduate School, 1300 York Avenue, New York, 10065, New York, USAAlejandro Lopez-MontesDepartment of Nuclear Medicine, Bern University Hospital, Freiburgstrasse 4, Bern, 3010, SwitzerlandJoaquin L. HerraizNuclear Physics Group, EMFTEL and IPARCOS, University Complutense of MadridInstituto de Investigación Sanitaria, Hospital Clínico San Carloshttp://arxiv.org/abs/2510.11670v2Collagen and myocyte interplay in cardiac volume overload: a multi-constituent growth and remodeling framework2026-02-06T01:46:32ZHearts subjected to volume overload (VO) are prone to detrimental anatomical and functional changes in response to elevated mechanical loading, ultimately leading to heart failure. Experimental findings now emphasize that organ-scale changes following VO cannot be explained by myocyte growth alone, as traditionally proposed in the literature. Collagen degradation, in particular, has been associated with VO and assumed to play a central role in both its acute and chronic stages. This hypothesis, however, remains to be substantiated by comprehensive mechanistic evidence, and each constituent contribution to myocardial growth and remodeling (G&R) processes is yet to be quantified. In this work, we present a multi-constituent G&R framework that integrates a mixture-based constitutive model within the kinematic growth formulation. This framework enables us to mechanistically assess the relative contributions of collagen and myocyte changes to alterations in tissue properties, ventricular dimensions, and growth phenotype. Our numerical results confirm that collagen remodeling affects the passive mechanical response of the myocardium, whereas myocytes predominantly influence the extent and phenotype of VO-induced growth. Importantly, collagen degradation exacerbates myocyte hypertrophy, revealing a synergistic interplay that accelerates the left ventricular eccentric growth and thereby promotes systolic dysfunction. This work constitutes an important step towards an integrated characterization of the early compensatory stages of VO-induced cardiac G&R.2025-10-13T17:43:08ZLudovica MagaMathias PeirlinckLise Noëlhttp://arxiv.org/abs/2602.05908v1Self-Portrait of the Focusing Process in Speckle: III. Tailoring Complex Spatio-Temporal Focusing Laws To Overcome Reverberations in Reflection Imaging2026-02-05T17:24:18ZThis is the third article in a series of three dealing with the exploitation of speckle for imaging purposes. In complex media, a fundamental limit is the multiple scattering phenomenon that completely blurs the imaging process in depth. Matrix imaging can provide a relevant framework for solving this problem. As it proved to be an adequate tool for probing reverberations in speckle [E. Giraudat et al., Part I], we will show how it can be used to tailor complex spatio-temporal focusing laws to monitor the interference between the multiply-reflected paths and the ballistic component of the wave-field. To do so, we extend the distortion matrix concept to the frequency domain. An iterative phase reversal process operated from the space-time Fourier space is then used to compensate for reverberations and optimize both the axial and transverse resolution of the confocal image. Here, we first present an experimental proof-of-concept consisting in imaging a tissue-mimicking phantom through a reverberating plate before outlining the potential and the limits of this strategy for transcranial ultrasound and beyond.2026-02-05T17:24:18Z29 pages, 8 figures, 2 tablesElsa GiraudatFlavien BureauWilliam LambertMathias FinkAlexandre Aubryhttp://arxiv.org/abs/2602.05907v1Self-Portrait of the Focusing Process in Speckle: I. Spatio-Temporal Imaging of Wave Packets in Complex Media2026-02-05T17:23:23ZThis is the first article in a series of three dealing with the exploitation of speckle for imaging purposes. Speckle is the complex interference wave-field produced by a random distribution of un-resolved scatterers. In this paper, we show how these scatterers can be used as virtual microphones to monitor the spatio-temporal propagation of a wave-packet inside the medium. To do so, the concept of matrix imaging is particularly useful. It consists in decoupling the location of the transmitted and received focal spots in a standard beamforming process. By scanning the wave-field with the output focal spot that then acts as a virtual transducer, one can image the spatio-temporal evolution of the wave-packet inside the medium. This unique observable will allow us to highlight the imperfections of the focusing process, in particular the defocus and reverberations induced by a strong aberrating layer. As a proof-of-concept, we will consider ultrasound experiments on tissue-mimicking phantoms. In the next two papers, we will show how this observable can be leveraged to compensate for these phenomena that hamper wave focusing and imaging in all fields of wave physics. Our method is indeed broadly applicable to different types of waves beyond ultrasound for which multi-element technology allows a reflection matrix to be measured.2026-02-05T17:23:23Z39 pages, 11 figures, 1 tableElsa GiraudatFlavien BureauWilliam LambertMathias FinkAlexandre Aubryhttp://arxiv.org/abs/2409.13901v2Self-Portrait of the Focusing Process in Speckle: II. Gouy Phase Shift for Defocus Correction and Pixel Depth Reassignment2026-02-05T17:12:43ZThis is the second article in a series of three dealing with the exploitation of speckle for aberration correction and reverberation compensation in reflection imaging. When probing heterogeneous media with waves, we have to cope with multi-scale fluctuations of the wave velocity. On the one hand, short-scale heterogeneities induce back-scattered echoes whose random interference generate a speckle pattern on the beamformed image. On the other hand, large-scale fluctuations of the wave-velocity can distort the focused wave-fronts, resulting in aberrations on the same image. In this paper, we show how the self-portrait of the wave evolves as a function of the speed-of-sound model. Strikingly, a Gouy phase shift is observed when the speed-of-sound model is optimal. This particularly sensitive feature enables: (i) an optimization of the speed-of-sound model for each pixel of the image; (ii) a local and fine compensation of defocus across the field-of-view, thereby compensating for most aberrations in the image. Experiment in a tissue-mimicking phantom and numerical simulations are first presented to validate our method. It is then applied to in-vivo liver data of a difficult-to-image patient. The speed-of-sound optimization allows an axial compensation of aberrations and a depth-reassignment of each singly-scattered echo to the actual position of the associated scatterer. As distance measurement is often critical for diagnosis, such a wave speed optimization can be crucial for ultrasound but also for any other imaging methods based on the principle of echo-location.2024-09-20T21:05:51Z43 pages, 8 figures, 3 tablesFlavien BureauEmma BrennerNaiara Korta MartiartuElsa GiraudatArthur Le BerWilliam LambertLouis CarmierAymeric GuibalMathias FinkAlexandre Aubryhttp://arxiv.org/abs/2602.07060v1U-Net Based Image Enhancement for Short-time Muon Scattering Tomography2026-02-05T10:11:15ZMuon Scattering Tomography (MST) is a promising non-invasive inspection technique, yet the practical application of short-time MST is hindered by poor image quality due to limited muon flux. To address this limitation, we propose a U-Net-based framework trained on Point of Closest Approach (PoCA) images reconstructed with simulation MST data to enhance image quality. When applied to experimental MST data, the framework significantly improves image quality, increasing the Structural Similarity Index Measure (SSIM) from 0.7232 to 0.9699 and decreasing the Learned Perceptual Image Patch Similarity (LPIPS) from 0.3604 to 0.0270. These results demonstrate that our method can effectively enhance low-statistics MST images, thereby paving the way for the practical deployment of short-time MST.2026-02-05T10:11:15ZHaochen WangPei YuLiangwen ChenWeibo HeYu ZhangYuhong YuXueheng ZhangLei YangZhiyu Sunhttp://arxiv.org/abs/2602.05453v1Towards Segmenting the Invisible: An End-to-End Registration and Segmentation Framework for Weakly Supervised Tumour Analysis2026-02-05T08:55:26ZLiver tumour ablation presents a significant clinical challenge: whilst tumours are clearly visible on pre-operative MRI, they are often effectively invisible on intra-operative CT due to minimal contrast between pathological and healthy tissue. This work investigates the feasibility of cross-modality weak supervision for scenarios where pathology is visible in one modality (MRI) but absent in another (CT). We present a hybrid registration-segmentation framework that combines MSCGUNet for inter-modal image registration with a UNet-based segmentation module, enabling registration-assisted pseudo-label generation for CT images. Our evaluation on the CHAOS dataset demonstrates that the pipeline can successfully register and segment healthy liver anatomy, achieving a Dice score of 0.72. However, when applied to clinical data containing tumours, performance degrades substantially (Dice score of 0.16), revealing the fundamental limitations of current registration methods when the target pathology lacks corresponding visual features in the target modality. We analyse the "domain gap" and "feature absence" problems, demonstrating that whilst spatial propagation of labels via registration is feasible for visible structures, segmenting truly invisible pathology remains an open challenge. Our findings highlight that registration-based label transfer cannot compensate for the absence of discriminative features in the target modality, providing important insights for future research in cross-modality medical image analysis. Code an weights are available at: https://github.com/BudhaTronix/Weakly-Supervised-Tumour-Detection2026-02-05T08:55:26ZAccepted for AIBio at ECAI 2025Artificial Intelligence for Biomedical Data, AIBIO 2025, CCIS 2696, pp 229-242, 2026Budhaditya MukhopadhyayChirag MandalPavan TummalaNaghmeh MahmoodianAndreas NürnbergerSoumick Chatterjee10.1007/978-3-032-17216-7_18http://arxiv.org/abs/2602.05077v1Laterally Oscillating Trajectory for Undersampling Slices: LOTUS2026-02-04T21:52:55ZPurpose: While spiral sampling offers SNR advantages for diffusion MRI, its acceleration with simultaneous multislice remains relatively unexplored. This study introduces Laterally Oscillating Trajectory for Undersampling Slices (LOTUS), which is a 3D spiral-like k-space trajectory that aims to minimize g-factor via controlled incoherent aliasing. To aid in validation, we also introduce a robust method to estimate g-factor for iterative non-Cartesian reconstructions.
Methods: Simulated data sampling of a numerical phantom was performed using LOTUS and several acquisition schemes proposed by others to quantitatively compare the resulting image quality when compared to a known ground truth. Diffusion-weighted in vivo brain data from two subjects was acquired with two in-plane acceleration factors (2x and 4x), and two slice acceleration factors (2x and 4x). Estimated g-factor maps and fractional anisotropy maps were calculated to quantitatively and qualitatively compare trajectory performance. For both simulation and in vivo, reconstructions both with and without compressed sensing were utilized.
Results: Simulations generally showed decreased g-factor (20%-31%, depending on trajectory, at highest undersampling rate) and improved reconstruction accuracy (mean-square error, structural similarity index, and entropy metrics) for LOTUS compared to the other trajectories. The in vivo acquisitions demonstrated g-factor benefits and qualitative image quality improvements that mirrored the simulation results. For both simulation and in vivo, improvements for LOTUS increased for higher numbers of simultaneous slices.
Conclusion: By enabling higher rates of slice acceleration, LOTUS shows promise for decreasing scan time, which is especially beneficial for diffusion MRI.2026-02-04T21:52:55Z31 pages, 8 figures, 3 supplementary figures, submitted to Magnetic Resonance in MedicineMayuri SothynathanPaul I. DubovanCorey. A. Baronhttp://arxiv.org/abs/2509.05047v2Object independent scatter sensitivities for PET, applied to scatter estimation through fast Monte Carlo simulation2026-02-04T13:59:59ZScattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit detector physics. Incorporating detector sensitivities for scatter is challenging because scattered events exhibit less constrained properties, such as incidence angles, compared to true coincidences. We integrated a 5D single-photon detection probability lookup table (LUT) accounting for photon energy, incidence angle, and detector location into the simulator logic. The resulting scatter sinogram is scaled by a precomputed, LUT-specific scatter sensitivity sinogram. Scatter was simulated using MCGPU-PET, a fast Monte Carlo (MC) simulator with a simplified scanner model, and applied to phantom data from a simulated GE Signa PET/MR in GATE. We evaluated three scenarios: (1) high-count MC simulations from a known activity distribution; (2) limited-count simulations; and (3) joint estimation of activity and scatter under low-count conditions. The method was also tested on two real Signa PET/MR acquisitions. In scenario 1, scatter-compensated reconstructions achieved <1% global bias in all active regions. In scenario 2, noisy scatter estimates caused positive bias, but Gaussian smoothing restored accuracy to scenario 1 levels. In scenario 3, joint estimation maintained <1% bias in nearly all regions. For real scans, the MC-based scatter estimate closely matched the vendor-provided scatter estimate. This proof-of-concept demonstrates that scatter sensitivity modeling can enhance simulators by incorporating detector physics. It supports the feasibility of using fast MC simulations for real scans, offering improved accuracy and robustness to acquisition noise in clinical PET reconstruction.2025-09-05T12:23:45Z23 pages, 14 figures, accepted and published by Physics in Medicine and BiologyPhysics in Medicine Biology, vol. 71, p. 025020, jan 2026Simon NoëKU LeuvenSeyed Amir Zaman PourKU LeuvenAhmadreza RezaeiKU LeuvenCharles StearnsGE HealthCareJohan NuytsKU LeuvenGeorg SchrammKU Leuven10.1088/1361-6560/ae3a31http://arxiv.org/abs/2511.16465v5Mesoscale tissue properties and electric fields in brain stimulation: Bridging the macroscopic and microscopic scales using layer-specific cortical conductivity2026-02-04T13:31:47ZAccurate simulations of electric fields (E-fields) in neural stimulation depend on tissue conductivity representations that link underlying microscopic tissue structure with macroscopic assumptions. Mesoscale conductivity variations can produce meaningful changes in E-fields and neural activation thresholds but remain largely absent from standard macroscopic models. Conductivity variations within the cortex are expected given the differences in cell density and volume fraction across layers. We review recent efforts modeling microscopic and mesoscopic E-fields and outline approaches that bridge micro- and macroscales to derive consistent mesoscale conductivity distributions. Using simplified microscopic models, effective tissue conductivity was estimated as a function of volume fraction of extracellular space, and the conductivities of different cortical layers were interpolated based on experimental volume fraction. The effective tissue conductivities were monotonically decreasing convex functions of the cell volume fraction. With decreasing cell volume fraction, the conductivity of cortical layers increased with depth from layer 2 to 6. Although the variation of conductivity within the cortex was small when compared to the conductivity of extracellular fluid (9% to 15%), the conductivity difference was considerably larger when compared between layers, e.g., with layer 3 and 6 being 20% and 50% more conductive than layer 2, respectively. The review and analysis provide a foundation for accurate multiscale models of E-fields and neural stimulation. Using layer-specific conductivity values within the cortex could improve the accuracy of estimations of thresholds and distributions of neural activation in E-field models of brain stimulation.2025-11-20T15:29:43Z20 pages, 6 figures, 4 tables2026, J. Neural Eng., 23(3), 036026Boshuo WangTorge H. WorbsMinhaj A. HussainAman S. AberraAxel ThielscherWarren M. GrillAngel V. Peterchev10.1088/1741-2552/ae6ff0http://arxiv.org/abs/2602.04461v1Human-organ-scale x-ray fluorescence ghost imaging for radioisotope-free diagnostics2026-02-04T11:45:44ZA wide range of diagnostic information in medicine is currently obtained using radioactive tracers. While central to nuclear medicine, these methods are inherently constrained: radiation dose limits repeat examinations, short tracer half-lives and complex logistics restrict access and raise costs, and their relatively poor spatial resolution often necessitates complementary CT or MRI. Here we present a first proof-of-concept demonstration of a non-radioactive alternative based on x-ray fluorescence (XRF) computational ghost imaging (CGI) at the human-organ scale. Using a thyroid phantom filled with iodine solution as a model system, we show that structured illuminations combined with fluorescence detection reconstruct the iodine distribution with high fidelity. This approach eliminates the need for radioactive tracers while preserving image quality, and in principle can reach spatial resolution comparable to CT. Beyond this demonstration, XRF-CGI establishes a generalizable framework for non-radioactive tracer imaging, opening a route toward safer, repeatable, and more accessible diagnostics.2026-02-04T11:45:44Z5 figures, 13 pagesE. LevinsonR. H. ShukrunN. ViganoS. Shwartzhttp://arxiv.org/abs/2602.03744v2Reducing acquisition time and radiation damage: data-driven subsampling for spectro-microscopy2026-02-04T10:15:44ZSpectro-microscopy is an experimental technique which can be used to observe spatial variations in chemical state and changes in chemical state over time or under experimental conditions. As a result it has broad applications across areas such as energy materials, catalysis, environmental science and biological samples. However, the technique is often limited by factors such as long acquisition times and radiation damage. We present two measurement strategies that allow for significantly shorter experiment times and total doses applied. The strategies are based on taking only a small subset of all the measurements (e.g. sparse acquisition or subsampling), and then computationally reconstructing all unobserved measurements using mathematical techniques. The methods are data-driven, using spectral and spatial importance subsampling distributions to identify important measurements. As a result, taking as little as 4-6\% of the measurements is sufficient to capture the same information as in a conventional scan.2026-02-03T17:05:27ZMaike MeierLorenzo LazzarinoBoris ShustinHussam Al DaasPaul Quinnhttp://arxiv.org/abs/2602.03281v2Physics-Based Learning of the Wave Speed Landscape in Complex Media2026-02-04T09:03:08ZWave velocity is a key parameter for imaging complex media, but in vivo measurements are typically limited to reflection geometries, where only backscattered waves from short-scale heterogeneities are accessible. As a result, conventional reflection imaging fails to recover large-scale variations of the wave velocity landscape. Here we show that matrix imaging overcomes this limitation by exploiting the quality of wave focusing as an intrinsic guide star. We model wave propagation as a trainable multi-layer network that leverages optimization and deep learning tools to infer the wave velocity distribution. We validate this approach through ultrasound experiments on tissue-mimicking phantoms and human breast tissues, demonstrating its potential for tumour detection and characterization. Our method is broadly applicable to any kind of waves and media for which a reflection matrix can be measured.2026-02-03T09:04:49Z40 pages, 8 figures, 1 tableBaptiste Hériard-DubreuilEmma BrennerBenjamin RioWilliam LambertFoucauld Chamming'sMathias FinkAlexandre Aubryhttp://arxiv.org/abs/2602.03622v1Quasi-multimodal-based pathophysiological feature learning for retinal disease diagnosis2026-02-03T15:13:57ZRetinal diseases spanning a broad spectrum can be effectively identified and diagnosed using complementary signals from multimodal data. However, multimodal diagnosis in ophthalmic practice is typically challenged in terms of data heterogeneity, potential invasiveness, registration complexity, and so on. As such, a unified framework that integrates multimodal data synthesis and fusion is proposed for retinal disease classification and grading. Specifically, the synthesized multimodal data incorporates fundus fluorescein angiography (FFA), multispectral imaging (MSI), and saliency maps that emphasize latent lesions as well as optic disc/cup regions. Parallel models are independently trained to learn modality-specific representations that capture cross-pathophysiological signatures. These features are then adaptively calibrated within and across modalities to perform information pruning and flexible integration according to downstream tasks. The proposed learning system is thoroughly interpreted through visualizations in both image and feature spaces. Extensive experiments on two public datasets demonstrated the superiority of our approach over state-of-the-art ones in the tasks of multi-label classification (F1-score: 0.683, AUC: 0.953) and diabetic retinopathy grading (Accuracy:0.842, Kappa: 0.861). This work not only enhances the accuracy and efficiency of retinal disease screening but also offers a scalable framework for data augmentation across various medical imaging modalities.2026-02-03T15:13:57ZZhang, L., Yu, H., Wang, Z., Gui, F., Guo, Y., Zhang, W., Jia, M., 2026. Quasi-multimodal-based pathophysiological feature learning for retinal disease diagnosis. Medical Image Analysis 109, 103886Lu ZhangHuizhen YuZuowei WangFu GuiYatu GuoWei ZhangMengyu Jia10.1016/j.media.2025.103886