https://arxiv.org/api/7nSzA1VMQ0YA0FlyOeUNycMznrw2026-06-22T08:17:25Z898539015http://arxiv.org/abs/2602.15672v1Dosimetric Study of Lung Modulation and Motion Effects in Carbon ion Therapy for Lung Cancer2026-02-17T15:55:04ZCarbon-ion radiotherapy provides high dose conformity for lung cancer, but its benefit is limited by two sources of uncertainties: interplay between scanned beam delivery and tumor motion, and dose modulation from heterogeneous lung tissue. This study quantifies the separate and combined dosimetric impact of these effects using the GSI TRiP4D treatment planning system. Eighteen lung cancer 4DCT datasets from TCIA were analyzed. A modulation power ($P_{\mathrm{mod}}$) was assigned to lung voxels. Three values were sampled from a Gaussian distribution ($200μ\mathrm{m} \pm 67μ\mathrm{m}$), and an extreme value of $750μ\mathrm{m}$ was tested. Interplay doses were computed by combining scanned-beam delivery with patient-specific respiratory motion. Four scenarios were studied: static, static with modulation, interplay, and interplay with modulation. Metrics included $D95\%$, $V95\%$, homogeneity index (HI), lung $V16\mathrm{Gy}$, and heart $V20\mathrm{Gy}$. Interplay reduced target coverage by $5.2 \pm 1.5$ pp ($D95\%$), $12.1 \pm 5.9$ pp ($V95\%$), and $8.3 \pm 2.4$ pp (HI). Extreme $P_{\mathrm{mod}}$ alone caused small degradations. When combined with interplay, it partially compensated the loss. This effect decreased with 4D optimization. Fractionation mitigated interplay, leaving lung modulation as the main residual effect.2026-02-17T15:55:04ZMaria Chiara MartireLennart VolzMarco DuranteChristian Graeffhttp://arxiv.org/abs/2602.15309v1OSCAR: An Ovipositor-Inspired Self-Propelling Capsule Robot for Colonoscopy2026-02-17T02:14:30ZSelf-propelling robotic capsules eliminate shaft looping of conventional colonoscopy, reducing patient discomfort. However, reliably moving within the slippery, viscoelastic environment of the colon remains a significant challenge. We present OSCAR, an ovipositor-inspired self-propelling capsule robot that translates the transport strategy of parasitic wasps into a propulsion mechanism for colonoscopy. OSCAR mechanically encodes the ovipositor-inspired motion pattern through a spring-loaded cam system that drives twelve circumferential sliders in a coordinated, phase-shifted sequence. By tuning the motion profile to maximize the retract phase relative to the advance phase, the capsule creates a controlled friction anisotropy at the interface that generates net forward thrust. We developed an analytical model incorporating a Kelvin-Voigt formulation to capture the viscoelastic stick--slip interactions between the sliders and the tissue, linking the asymmetry between advance and retract phase durations to mean thrust, and slider-reversal synchronization to thrust stability. Comprehensive force characterization experiments in ex-vivo porcine colon revealed a mean steady-state traction force of 0.85 N, closely matching the model. Furthermore, experiments confirmed that thrust generation is speed-independent and scales linearly with the phase asymmetry, in agreement with theoretical predictions, underscoring the capsule's predictable performance and scalability. In locomotion validation experiments, OSCAR demonstrated robust performance, achieving an average speed of 3.08 mm/s, a velocity sufficient to match the cecal intubation times of conventional colonoscopy. By coupling phase-encoded friction anisotropy with a predictive model, OSCAR delivers controllable thrust generation at low normal loads, enabling safer and more robust self-propelling locomotion for robotic capsule colonoscopy.2026-02-17T02:14:30ZMostafa A. AtallaAnand S. SekarRemi van StarkenburgDavid J. JagerAimée SakesMichaël WiertlewskiPaul Breedveldhttp://arxiv.org/abs/2505.11155v2Controlling spatial correlation in k-space interpolation networks for MRI reconstruction: denoising versus apparent blurring2026-02-16T16:18:16ZPurpose: Interpretability is essential for the clinical adoption of state-of-the-art machine learning (ML) methods in magnetic resonance imaging (MRI). Conventional evaluation of ML reconstructions relies heavily on aggregate image metrics that require fully sampled references. These metrics, inherited from classical image processing and natural image ML, often overlook the critical challenge of noise amplification specific to medical image reconstruction. This study aims to analyze the influence of nonlinear activations on spatial noise variance distribution of k-space interpolation networks (RAKI) and to provide a framework for incorporating variance maps during network training. Methods: We present an analytical framework that decomposes pixel-level noise variance into components reflecting linear and nonlinear characteristics of RAKI. By applying automatic differentiation on the image-space equivalent of the network, variance maps are computed during each training iteration, enabling runtime quality assessment beyond data consistency. We introduce apparent blurring, quantifying nonlinear signal mixing without dependence on reference images. By incorporating variance maps into the traning loss as regularizers, our self-informed RAKI architecture (G-factor-informed RAKI, GIF-RAKI) can directly integrate updated noise characteristics during runtime. Results: Experimental results demonstrate that variance components quantitatively explain network behavior. GIF-RAKI outperforms conventional RAKI variants in image fidelity and noise suppression. Conclusion: Our methodology advances practical and theoretical aspects of ML-based MRI reconstruction by reinstating reconstruction noise characterization as a cornerstone for performance evaluation, eliminating the need for fully sampled references. GIF-RAKI also enables optimization of the trade-off between denoising and apparent blurring.2025-05-16T11:57:31ZIstvan HomolyaJannik StebaniFelix BreuerGrit HeinMatthias GamerFlorian KnollMartin Blaimerhttp://arxiv.org/abs/2602.14639v1Biomechanics of the abdominal wall before and after ventral hernia repair using dynamic MRI2026-02-16T10:55:06ZPurpose: This study aims to investigate the use of dynamic MRI to assess abdominal wall biomechanics before and after hernia surgery, considering that such evaluations can enhance our understanding of physiopathology and contribute to reducing recurrence rates. Methods: Patients were assessed using dynamic MRI in axial and sagittal planes while performing exercises (breathing, coughing, Valsalva) before and after their abdominal hernia surgery with mesh placement. Rectus and lateral muscles, linea alba, viscera area, defect dimensions and hernia sac were contoured with semi-automatic process to quantify the abdominal wall biomechanical temporal modifications. Results: This study enrolled 11 patients. During coughing, the axial area of the hernia sac increased by 128.4 $\pm$ 199.2%. The sac increased similarly in axial and sagittal planes during Valsalva. Post-surgical evaluations showed a 26% reduction in inter-recti distance and a lengthening of all muscles (p $\le$ 0.05). The post-operative rectus abdominis thickness change was negatively correlated with defect width during breathing (p $\le$ 0.05). The largest change in linea alba displacement was observed in the surgical site (p = 0.07). Post-operatively, lateral muscles had a larger inward displacement during Valsalva (p $\le$ 0.05). Rectus abdominis had a larger outward displacement during breathing (p = 0.09), reduced with the mesh size (p $\le$ 0.05). A large inter-individual variability was observed. Conclusion: Using a semi-automatic methodology, an in-depth analysis of the biomechanics of the abdominal wall was conducted, highlighting the importance of a patient-specific assessment. A broader study and consideration of recurrence would subsequently complete this methodological work.2026-02-16T10:55:06ZHernia, 2025, 29 (1), pp.185Victoria JoppinLBA UMR T24, CRMBMDavid BendahanCRMBMAhmed Ali El AhmadiLBA UMR T24Catherine MassonLBA UMR T24Thierry BegeLBA UMR T24http://arxiv.org/abs/2602.14315v1Complex Wavelet-Based Sinogram Segmentation for Metal Artifact Reduction in Cone-Beam CT2026-02-15T21:33:25ZMetal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These artifacts degrade image quality and limit the reliability of subsequent medical analysis. We propose a projection-domain metal artifact reduction method based on analytical metal segmentation in the three-dimensional sinogram using the three-dimensional Dual-Tree Complex Wavelet Transform, where directional wavelet coefficients are exploited to extract the wavefront set and singular support of metal structures. The resulting segmentation enables projection-domain inpainting and artifact-reduced reconstruction by combining metal-free and metal-only reconstructions. The proposed approach is evaluated on both simulated and clinical cone-beam computed tomography data and consistently reduces metal artifacts compared to conventional image-domain hard-thresholding methods. The results demonstrate improved visual quality and robustness in clinically realistic scenarios, highlighting the potential of analytically grounded, non-learned projection-domain segmentation for metal artifact reduction.2026-02-15T21:33:25ZSiiri RautioAlexander MeaneySalla-Maaria Latva-ÄijöHarshit AgrawalMikael BrixDinidu JayakodySamuli Siltanenhttp://arxiv.org/abs/2510.10786v2Electron-hole liquid in biological tissues under ultra high dose rate ionizing radiation2026-02-15T20:23:33ZWe develop a quantitative model of ionization processes in biological tissues under Ultra High Dose Rate (UHDR) radiation. The underlying conjecture is that of electron-hole liquid (EHL) forming in water based substances of biological tissues. Unlike the earlier known EHL in semiconductor crystals, the charge carriers here are low mobile due to strong interactions with the background (solvated electrons, etc.); hence, EHL resembling ionic melts. Similar to all ionic systems, the Coulomb coupling makes that EHL energetically favorable that leads to recombination barriers suppressing subsequent structural transformations. In particular, generation of secondary reactive species in such EHL becomes limited translating into reduction of biological damages and tissue sparing effect. We show how these processes are sensitive to the tissue quality and frequency dispersion of the dielectric permittivity. Equations for dose and dose rate defining the sparing thresholds are derived.2025-10-12T20:04:54Z6 pages, 5 figuresDiana ShvydkaVictor Karpov10.1103/3ly7-yswyhttp://arxiv.org/abs/2602.23386v1Controlled release from polyurethane films: drug release mechanisms2026-02-15T20:21:03ZIn this study, polyurethane-films loaded diclofenac were used to analyze the drug release kinetics and mechanisms. For this purpose, the experimental procedures were developed under static and dynamic conditions with different initial drug loads of 10, 20, and 30%. In the dynamic condition, to better simulate the biological flow, drug release measurements were investigated at flow rates of 7.5 and 23.5 ml/s. These values indicate the flow rate of the internal carotid artery (ICA) for a normal state of a body and for a person during the exercise, respectively. The experimental data were analyzed and adjusted by Higuchi, Korsmeyer-Peppas, First-order, zero-order, and Peppas-Sahlin models in order to understand the mechanisms contributed. Finally, Drug release mechanisms were specified by investigating the model correlation coefficients. Experimental results showed that increasing the flow rate and initial drug loads enhance drug liberation. In addition, the rate of release is more influenced by the drug dosage in the static state. The analysis revealed that diffusion, burst, and osmotic pressure are the principal mechanisms contributed. Moreover, Fickian type was the dominant mechanism at all duration of release. However, it was discovered using Peppas-Sahlin model that the contribution of the diffusion mechanism decreases with increasing flow rate and initial dosage. Furthermore, the tests at different drug dosages showed that the number of stages in medication release profile is independent of the flow rate and the medicine percentage. One can conclude that the drug release kinetic in static state is more influenced by drug dosage compare to dynamic state.2026-02-15T20:21:03ZJournal of Applied Polymer Science, 138 (2021) 50083N. AbbasnezhadN. ZirakM. ShirinbayanS. KouidriE. SalahinejadA. TcharkhtchiF. Bakir10.1002/app.50083http://arxiv.org/abs/2602.14264v1Magnetocardiography measurements using an optically pumped magnetometer under ambient conditions2026-02-15T18:29:54ZIn this work, we report the development of a rubidium-based single-beam scalar optically pumped magnetometer (OPM) and demonstrate its application in measuring human cardiac magnetic fields in an unshielded environment. The developed magnetometers exhibit a noise floor below 15 pT/sqrt(Hz) in the frequency range of 1 to 35 Hz, with a measurement bandwidth of 100 Hz. When operated in a gradiometric configuration, the noise floor is further reduced to below 3 pT/sqrt(Hz) over the same frequency range. Magnetocardiography (MCG) signals were recorded at five different locations across the thorax. A clear polarity reversal of the QRS complex was observed across these measurement positions, confirming the spatial sensitivity of the system. The proposed system shows strong potential for clinical diagnostics, offering valuable physiological information through non-contact MCG measurements2026-02-15T18:29:54ZKushal PatelKesavaraja CPranab DuttaKorak Biswashttp://arxiv.org/abs/2602.06212v2Causal machine learning reveals age-dependent radiation dose effects on mandibular osteoradionecrosis2026-02-15T04:46:31ZDistinguishing causal relationships from statistical correlations remains a fundamental challenge in clinical research, limiting the translation of observational findings into interventional treatment guidelines. Here we apply causal machine learning to establish causal effects of radiation dose parameters on mandibular osteoradionecrosis (ORN) in 931 head and neck cancer patients treated with volumetric-modulated arc therapy. Using generalized random forests, we demonstrate that all examined dosimetric factors exhibit significant positive causal effects on ORN development (average treatment effects: 0.092-0.141). Integration with explainable machine learning reveals substantial treatment effect heterogeneity, with patients aged 50-60 years showing the strongest causal dose-response relationships (conditional average treatment effects up to 0.229), while patients over 70 years demonstrate minimal effects. These results suggest that age-stratified treatment optimization and personalized treatment planning for the dosimetric factors could reduce ORN risk. Our findings demonstrate that causal inference methods can transform clinical retrospective radiotherapy data into personalized treatment recommendations, providing a methodological framework applicable to toxicity prediction across oncology and other clinical domains where treatment decisions depend on complex dose-response relationships.2026-02-05T21:42:09ZJingyuan ChenYunze YangOlivia M. MullerLei ZengZhengliang LiuTianming LiuRobert L FooteDaniel J MaSamir H PatelZhong LiuWei Liuhttp://arxiv.org/abs/2506.04748v2Synchro-Thermography: Monitoring ~10 mK Facial Temperature Changes with Heartbeat Referencing for Physiological Sensing2026-02-14T01:59:25ZInfrared thermography has gained interest as a tool for non-contact measurement of blood circulation and skin blood flow due to cardiac activity. Partiularly, blood vessels on the surface, such as on the back of the hand, are suited for visualization. However, standardized methodologies have not yet been established for areas such as the face and neck, where many blood vessels are lie deeper beneath the surface, and external stimulation for measurement could be harmful. Here we propose Synchro-Thermography for stable monitoring of facial temperature changes associated with heart rate variability. We conducted experiments with eight subjects and measured minute temperature changes with an amplitude of about \SI{10}{mK} on the forehead and chin. The proposed method improves the temperature resolution by a factor of 2 or more, and can stably measure skin temperature changes caused by blood flow. This skin temperature change could be applied to physiological sensing such as blood flow changes due to injury or disease, or as an indicator of stress.2025-06-05T08:31:41ZThis paper has been submitted to the 2025 SICE Festival with Annual Conference (SICE FES 2025)2025 SICE Festival with Annual Conference (SICE FES) (2025) 1249-1254Nanami KotaniKuniharu SakuradaJiayi XuMasahiko InamiYasuaki Monnai10.23919/SICEFES67750.2025.11236693http://arxiv.org/abs/2602.13535v1Biocompatibility of Additively Manufactured Fe-AZ31 Biodegradable Composites for Craniofacial Implant Applications2026-02-14T00:22:03ZMetallic plating systems composed of titanium and its alloys remain the standard treatment for craniofacial bony fixation but may require secondary removal due to infection, implant migration, or discomfort. Thus, biodegradable metallic implants may eliminate complications and secondary procedures while maintaining structural integrity. Our previous work demonstrated the fabrication of immiscible Fe-AZ31 composites via additive manufacturing with improved degradation kinetics over pure Iron. This study aimed to evaluate the in vitro and in vivo biocompatibility of Fe-AZ31 composites for potential craniofacial fixation applications. Pure iron (Fe), Mg alloy (AZ31) and Fe-AZ31 samples were fabricated for extract-based cytotoxicity testing using HFF-1 fibroblasts, L929 fibroblasts and hFOB osteoblasts. Metal extracts were prepared at a 3 cm^2/mL surface-to-volume ratio in complete media at 37C and cell viability was measured by live/dead assay after 24 and 72h exposure. For in vivo evaluation, Fe-AZ31, Fe, and Ti plates were implanted subcutaneously in wild type mice for 6 weeks, 3 and 6 months. Implant degradation, histologic response, hematology, and serum biochemistry were assessed. Fe-AZ31 extracts demonstrated >70% cell viability across all cell types at both timepoints with normal cell morphology and adhesion, whereas AZ31 extracts caused marked cytotoxicity associated with pronounced alkalization (pH 10). In vivo, Fe-AZ31 implants exhibited gradual surface corrosion accompanied by mild, transient inflammation and minimal capsule formation over time. No systemic toxicity was observed. Hematology and serum biochemistry remained within physiological limits. Additively manufactured Fe-AZ31 composites demonstrate acceptable biocompatibility and favorable tissue responses, supporting their development as resorbable metallic fixation devices for craniofacial reconstruction.2026-02-14T00:22:03ZXue DongSamuel MedinaSai Pratyush AkulaAbby Chopoorian FuchsmanMatthew W. LiaoSophia SalingarosAtieh MoridiJason A. Spectorhttp://arxiv.org/abs/2311.17824v2Depth-multiplexing spectral domain OCT for full eye length imaging with a single modulation unit2026-02-13T22:29:28ZClinical measurement of a patient's axial eye length is emerging as a crucial approach to track progression and monitor management of myopia. However, the preferred method for such measurements is swept-source OCT, whose cost prohibits broad use, especially in lower-income communities. Spectral domain (SD) OCT is a more affordable option, but it has limited imaging depth range, so is not suitable for full eye length measurement. Depth-multiplexing (DM) techniques for SD-OCT provide a workaround by capturing images at multiple depths within the eye. However, these methods typically require multiple light modulation units or detectors for simultaneous imaging across depths, adding complexity and cost. In response, we propose a novel DM-SD-OCT approach that utilizes a single light modulation unit for depth encoding. We capture images at multiple depths within the eye simultaneously with a single line scan camera, then computationally demix the contributions from different depths. Here, we demonstrate acquisition and demixing of signals from three distinct depths within the eye and validate experimentally in human subjects. Our method thus offers a cost-effective solution for comprehensive eye length measurement in clinical myopia research.2023-11-29T17:24:26ZGuanghan MengXue DongAndrew ZhangFabio FeroldiAustin RoordaLaura Wallerhttp://arxiv.org/abs/2602.12933v1Deep-Learning Atlas Registration for Melanoma Brain Metastases: Preserving Pathology While Enabling Cohort-Level Analyses2026-02-13T13:43:57ZMelanoma brain metastases (MBM) are common and spatially heterogeneous lesions, complicating cohort-level analyses due to anatomical variability and differing MRI protocols. We propose a fully differentiable, deep-learning-based deformable registration framework that aligns individual pathological brains to a common atlas while preserving metastatic tissue without requiring lesion masks or preprocessing.
Missing anatomical correspondences caused by metastases are handled through a forward-model similarity metric based on distance-transformed anatomical labels, combined with a volume-preserving regularization term to ensure deformation plausibility. Registration performance was evaluated using Dice coefficient (DSC), Hausdorff distance (HD), average symmetric surface distance (ASSD), and Jacobian-based measures. The method was applied to 209 MBM patients from three centres, enabling standardized mapping of metastases to anatomical, arterial, and perfusion atlases.
The framework achieved high registration accuracy across datasets (DSC 0.89-0.92, HD 6.79-7.60 mm, ASSD 0.63-0.77 mm) while preserving metastatic volumes. Spatial analysis demonstrated significant over-representation of MBM in the cerebral cortex and putamen, under-representation in white matter, and consistent localization near the gray-white matter junction. No arterial territory showed increased metastasis frequency after volume correction.
This approach enables robust atlas registration of pathological brain MRI without lesion masks and supports reproducible multi-centre analyses. Applied to MBM, it confirms and refines known spatial predilections, particularly preferential seeding near the gray-white matter junction and cortical regions. The publicly available implementation facilitates reproducible research and extension to other brain tumours and neurological pathologies.2026-02-13T13:43:57ZNanna E. WielenbergIlinca PoppOliver BlanckLucas ZanderJan C. PeekenStephanie E. CombsAnca-Ligia GrosuDimos BaltasTobias Fechterhttp://arxiv.org/abs/2602.12917v1Ultrasound-Guided Real-Time Spinal Motion Visualization for Spinal Instability Assessment2026-02-13T13:23:29ZPurpose: Spinal instability is a widespread condition that causes pain, fatigue, and restricted mobility, profoundly affecting patients' quality of life. In clinical practice, the gold standard for diagnosis is dynamic X-ray imaging. However, X-ray provides only 2D motion information, while 3D modalities such as computed tomography (CT) or cone beam computed tomography (CBCT) cannot efficiently capture motion. Therefore, there is a need for a system capable of visualizing real-time 3D spinal motion while minimizing radiation exposure.
Methods: We propose ultrasound as an auxiliary modality for 3D spine visualization. Due to acoustic limitations, ultrasound captures only the superficial spinal surface. Therefore, the partially compounded ultrasound volume is registered to preoperative 3D imaging. In this study, CBCT provides the neutral spine configuration, while robotic ultrasound acquisition is performed at maximal spinal bending. A kinematic model is applied to the CBCT-derived spine model for coarse registration, followed by ICP for fine registration, with kinematic parameters optimized based on the registration results. Real-time ultrasound motion tracking is then used to estimate continuous 3D spinal motion by interpolating between the neutral and maximally bent states.
Results: The pipeline was evaluated on a bendable 3D-printed lumbar spine phantom. The registration error was $1.941 \pm 0.199$ mm and the interpolated spinal motion error was $2.01 \pm 0.309$ mm (median).
Conclusion: The proposed robotic ultrasound framework enables radiation-reduced, real-time 3D visualization of spinal motion, offering a promising 3D alternative to conventional dynamic X-ray imaging for assessing spinal instability.2026-02-13T13:23:29ZFeng LiYuan BiTianyu SongZhongliang JiangNassir Navabhttp://arxiv.org/abs/2602.12655v1Image-based investigation of the zebrafish developmental process using in vivo dynamic and multi-contrast optical coherence tomography2026-02-13T06:32:38ZWe demonstrate in vivo dynamic optical coherence tomography (DOCT) imaging of zebrafish development from 2 weeks to 12 months post-fertilization, integrated with polarization-sensitive OCT (PS-OCT), OCT angiography (OCTA), and histological validation. Two DOCT algorithms were utilized: logarithmic intensity variance and late OCT correlation decay speed, which characterize the occupancy of dynamic scatterers and their motion speeds, respectively. Our results show that skin stripes exhibit high DOCT signals and it varies among the pigment-cell types. Furthermore, the combination of DOCT and PS-OCT captures the maturation of these stripes. In addition, DOCT and OCTA successfully visualized the developmental progression of blood and lymphatic vessels, as well as spinal tissues.2026-02-13T06:32:38ZCunyou BaoAiyi SuiIbrahim Abd El-SadekRion MorishitaYu GuoShuichi MakitaMakoto KobayashiYoshiaki Yasuno