https://arxiv.org/api/i6o+Bb1zkN3WJxlzavoEYjEa2I4 2026-06-22T07:06:05Z 8985 375 15 http://arxiv.org/abs/2602.21409v1 A CFD-Based Investigation of Local Luminal Curvature as a Primary Determinant of Hemodynamic Environments in Cerebral Aneurysms 2026-02-24T22:29:37Z The relationship between vascular morphology and hemodynamics is fundamental to understanding the natural history of cerebral aneurysms (CAs). While global geometric indices have been widely studied, the local interaction between luminal curvature and wall shear stress (WSS) remains poorly characterized. This study analyzed a large cohort of CAs to investigate how local surface morphology relates to hemodynamics. This was performed via CFD flow simulations of a set of 76 patient-specific CA geometries using the OpenFOAM library. Geometry and pulsatile inflow conditions were modeled based on patient arterial diameter and age. Blood was assumed to be a Newtonian incompressible fluid flowing in a laminar regime. We utilized a geometric framework to classify the aneurysm lumen into spherical-like and saddle-like patches based on Gaussian curvature. Our results demonstrate a robust, statistically significant correlation between these curvature types and hemodynamic metrics, regardless of rupture status or aneurysm type. Specifically, saddle-like patches, predominantly found at the aneurysm neck, are associated with high time-averaged WSS, a low oscillatory shear index, and intense near-wall vortical activity as identified by the lambda2-criterion. In contrast, spherical-like patches, dominant at the dome, correspond to regions of flow impingement characterized by lower time-averaged WSS and an elevated oscillatory shear index. These findings suggest that wall curvature is a primary determinant of local hemodynamics. By bridging the gap between local wall morphology and pathological wall markers, this work suggests that curvature-based mapping can serve as a powerful tool for identifying vulnerable regions susceptible to thinning and rupture. This objective geometric assessment offers valuable insights for risk stratification and the precision planning of endovascular interventions. 2026-02-24T22:29:37Z 42 pages, 12 figures Marcella P. A. Dallavanzi José L. Gasche Iago L. Oliveira http://arxiv.org/abs/2602.21354v1 Novel Asymmetrical High-Resolution and High-Sensitivity Brain Dedicated PET system: Design optimization and performance evaluation 2026-02-24T20:38:52Z Objective. This study investigates the best achievable performance of a brain-dedicated PET system with high resolution and sensitivity by evaluating different detector configurations, while maintaining a practical system design suitable for dynamic brain Imaging. Approach. Monte Carlo simulations were performed to evaluate system sensitivity and image quality under various timing resolutions (200 ps, 100 ps and 50 ps). The PET scanner geometry was optimized for human head imaging, featuring an elliptical cylindrical configuration with a neck cut-out, and front/back panels to enhance sensitivity and line of response (LOR) sampling. Detector configurations using LYSO:Ce crystals of varying thicknesses (15 mm and 20 mm) and depth of interaction (DOI) levels were simulated. Sensitivity was calculated using a point-like 511 keV back-to-back gamma source simulated at multiple locations within the field of view (FOV). Image reconstruction was conducted using list mode Maximum Likelihood Expectation Maximization (MLEM), assessing both a Derenzo-type phantom and a voxelated digital brain phantom. Main results. A location-dependent sensitivity ranging from 35.04% to 13.59% was achieved using a 20 mm thick LYSO:Ce crystal. Spatial resolution ranged from 0.8 mm to 1.5 mm within the FOV without applying resolution recovery techniques, measured using the FWHM of reconstructed hot rods. Previous results using 15 mm crystals with three DOI levels showed sensitivity between 23.42% and 15.99%, confirming the performance benefits of increased detector thickness and DOI capability. Significance. This study demonstrates the potential of a practical, brain-optimized PET system to achieve superior resolution and sensitivity for brain imaging. The findings offer valuable insights into optimal detector configurations, supporting the development of next-generation high-performance brain PET technologies. 2026-02-24T20:38:52Z Yuemeng Feng Lisa Blackberg Arkadiusz Sitek Hamid Sabet http://arxiv.org/abs/2602.20855v1 On the calculation of the radiobiological effect of radiolytic oxygen depletion in FLASH radiotherapy 2026-02-24T12:57:51Z Objective: Radiolytic oxygen depletion (ROD) may play a role in the sparing of cells irradiated with ultra-high dose rates. Different methods have been used to quantify the effect of ROD during FLASH irradiation on cell survival, typically involving some kind of averaging of the oxygen effect and the LQ model. In this work, we compare the results obtained with several of these methods and introduce a novel method based on the non-linear differential form of the LQ model. Approach: We present a novel method to account for a varying oxygen concentration on the dose-response based on the non-linear differential form of the LQ model, and we compare the results obtained with this method with those obtained with other methods that linearize the averaging of the oxygen effect during irradiation. Main results: We found differences in the surviving fractions obtained with the method introduced in this work and other methods that introduce different linearizations (averaging) of the non-linear dependence on the oxygen concentration, especially for oxygenations and doses that lead to important changes in the OERs during the delivery of the dose (initial oxygenations $\approx$5--10 mmHg and doses $>30$~Gy). On the other hand, we showed that the method presented by Zhu \emph{et al.} is equivalent to a first-order Euler numerical method of the differential LQ model. Significance: The method introduced in this work and the method of Zhu \emph{et al.} may allow a more precise quantification of the effect of ROD on dose-response, both for tumors and normal tissues. While all the reviewed methods show an oxygen-dependent sparing effect of FLASH radiotherapy driven by ROD and qualitatively similar results, the method introduced in this work and that of Zhu \emph{et al.} may be more suitable to quantitatively analyze new preclinical (and future clinical) data coming from experimental studies. 2026-02-24T12:57:51Z Juan Pardo-Montero Isabel González-Crespo http://arxiv.org/abs/2602.14803v4 A physics inspired and efficient transform for optoacoustic systems 2026-02-24T09:25:18Z Optoacoustic imaging technologies require fast and accurate signal pre-processing algorithms to enable widespread deployment in clinical and home-care settings. However, they still rely on the Discrete Fourier Transform (DFT) as the default tool for essential signal-conditioning operations, which imposes hard limits on both execution speed and signal-retrieval accuracy. Here, we present a new transform whose building blocks are directly inspired by the physics of optoacoustic signal generation. We compared its performance with the DFT and other classical transforms on common signal-processing tasks using both simulations and experimental datasets. Our results indicate that the proposed transform not only sets a new lower bound on computational complexity relative to the DFT, but also substantially outperforms classical transforms on basic signal-processing operations in terms of accuracy. We expect this transform to catalyze broader adoption of optoacoustic methods. 2026-02-16T14:54:00Z Maria Rodriguez Saenz de Tejada Alvaro Jimenez Rodrigo Rojo Sergio Contador Juan Aguirre http://arxiv.org/abs/2602.19829v1 Physics-Guided Dual-Domain Network with Attention-Based Fusion for Portable MRI Reconstruction 2026-02-23T13:28:05Z Portable low-field magnetic resonance imaging (MRI) systems have gained renewed interest owing to their cost effectiveness and point-of-care imaging capabilities. Yet, portable MRI systems suffer from relatively low signal-to-noise ratio and limited hardware capabilities. While previous works have proposed the use of deep learning based reconstruction methods to improve low-field image quality, these operated only in the image-domain. Unlike other imaging modalities, MRI directly acquires data in the Fourier-domain (k-space), and exploiting both k-space and image-domain information can improve reconstruction quality. Here, we introduce DUN-DD, a novel physics-guided 3D network for portable MRI reconstruction, with parallel dual-domain branches whose outputs are combined together via an attention-based fusion network. To demonstrate the performance of the proposed method, we present \textit{in vivo} reconstructions obtained from both emulated datasets as well as images acquired with a 47mT Halbach-based portable MRI system. Our results show that DUN-DD outperforms state-of-the-art classical, data-driven, and physics-guided methods on both emulated and real portable MRI acquisitions. 2026-02-23T13:28:05Z Accepted to 2026 IEEE International Symposium on Biomedical Imaging (ISBI). Copyright 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses Efe Ilıcak Baris Imre Chloé Najac Ruben van den Broek Beatrice Lena Andrew Webb Marius Staring http://arxiv.org/abs/2602.19712v1 SHARP: A compact focusing system for medical applications using a diverging plasma lens 2026-02-23T11:02:13Z Cancer therapy for deep-seated tumors requires precise irradiation of a small target deep within the patient while minimizing radiation exposure to surrounding tissues. This can be accomplished with a round beam sharply converging towards a single spot, requiring a large beam size in both planes at the exit of the focusing system. Achieving this over a short distance using only quadrupole lenses is challenging; but by using a linear active plasma lens (APL) in defocusing mode, the beam can be quickly and non-destructively enlarged before focusing using quadrupoles. The position of the irradiation spot can also be scanned in three dimensions by changing magnet settings. The SHARP project will develop and test this concept. Such a system can be used with very high energy electrons (hundreds of MeV), creating a Bragg-peak-like spot using novel accelerator technology. This could lead to more compact radiotherapy facilities, not requiring a bulky infrastructure typically associated with proton radiotherapy machines. If successful, SHARP will enable precision conformal radiotherapy, spatial fractionation, and potentially be useful for FLASH radiotherapy. 2026-02-23T11:02:13Z 18 pages, 9 figures. Submitted to the proceedings of the European Advanced Accelerator Conference (EAAC) 2025 Kyrre Ness Sjobak Elisabeth Rød-Lindberg Abélia Ellingsen Pierre Drobniak Vilde Flognfeldt Rieker Fardous Reaz Carl Andreas Lindstrøm Erik Adli http://arxiv.org/abs/2602.19264v1 A novel method for analysis of transient morphological changes in quasiperiodic physiological signals and their neurogenic correlates 2026-02-22T16:26:53Z Frequently, transient changes in physiological signals, such as ECG morphology, precede or follow a rate change. Current methods for visualizing morphology allow only the tracking of preselected changes, severely limiting analytical capabilities. We introduce a novel method for visualizing quasiperiodic signals, enabling the transformation of time series containing repetitive patterns into intuitive visual representations. By using segmentation algorithms and color encoding, we generate two-dimensional "carpet plots" that facilitate simultaneous assessment of heart rhythm and signal features, including the morphology of QRS complexes and T waves, as well as transient changes in intervals and amplitudes. Additionally, the method supports the assessment of concomitant changes in morphology and rate. Typically, existing visualization methods, such as the standard 12-lead ECG projection, focus either on rhythm variability or on morphological analysis of a few consecutive beats. In contrast, our method integrates both aspects into a single, coherent graphical representation, greatly enhancing the detection of subtle disturbances and a fascinating dynamic interplay between the rhythm and the morphology of the signal. We illustrate the effectiveness of this approach using Holter recordings from healthy individuals and patients with arrhythmias, as well as stress test sessions. The results highlight the potential of our visualization technique to support diagnosis and long-term ECG signal analysis. The method may be applied to a broad class of repeatable quasiperiodic patterns - we demonstrate a few examples. 2026-02-22T16:26:53Z 23 pages, 6 figures Tomasz Gradowski Damian Waląg Tomir Domański Teodor Buchner http://arxiv.org/abs/2603.05523v1 Predicting the onset of period-doubling bifurcations via dominant eigenvalue extracted from autocorrelation 2026-02-22T13:19:13Z Predicting the occurrence of transitions in the qualitative dynamics of many natural systems is crucial, yet it remains a challenging task. Generic early warning signals like variance and lag-1 autocorrelation identify critical slowing down near tipping points but lack practical thresholds for predicting imminent transitions. More recent studies found that the dynamical eigenvalue is rooted in the framework of empirical dynamical modeling and then estimates the dominant eigenvalue of a system from time series, providing a threshold ($|$DEV$|$ = 1) to predict bifurcations and classify their types. However, its application requires careful calibration of the hyperparameters and focuses on reconstructing system dynamics directly from data. Here, we employ Ornstein-Uhlenbeck process to derive analytic approximations for the lag-$τ$ autocorrelation function prior to period-doubling bifurcation thereby estimating the dominant eigenvalue of dynamical systems, named dominant eigenvalue extracted from autocorrelation (DE-AC), and revealing its dynamic behaviour when approaching a period-doubling bifurcation. Theoretically, dominant eigenvalue tends to $-1$ when the system approaches a period-doubling bifurcation. In particular, we evaluated DE-AC on simulation data from cardiac alternans model and on experimental data from chick heart aggregates undergoing a period-doubling bifurcation. DE-AC reliably detected the beginning of the cardiac arrhythmia (period-doubling bifurcation) in most cases. Moreover, it demonstrated superior sensitivity and specificity as an early warning signal compared to the three widely used indicators -- variance, lag-1 autocorrelation, and dynamical eigenvalue. Our theoretical and empirical results suggest that DE-AC represents a quantitative measure for predicting the onset of potentially dangerous alternating rhythms in the heart. 2026-02-22T13:19:13Z Zhiqin Ma Chunhua Zeng Ting Gao Jinqiao Duan 10.1016/j.chaos.2026.118010 http://arxiv.org/abs/2602.18318v1 Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector 2026-02-20T16:18:02Z In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$σ$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required. 2026-02-20T16:18:02Z Maxime Pinson Adélie André Yannick Boursier Mathieu Dupont Marie-Laure Gallin Martel Alicia Garnier Christophe Hoarau Pavel Kavrigin Daniel Maneval Christian Morel Jean-François Muraz Marco Pullia Simone Savazzi Sara Marcatili http://arxiv.org/abs/2602.17866v1 Simple non-invasive methods for obtaining the intensity and timing of arterial pulse waves 2026-02-19T22:02:34Z Contraction of the left ventricle of the heart increases aortic root blood pressure (P), diameter (D) and blood velocity (U). When contraction diminishes, all three properties decrease. These perturbations propagate down the systemic arteries as the S wave and D wave, respectively. Peak carotid artery S-wave intensity is diminished and delayed in heart failure with reduced ejection fraction (HFrEF). A clinical trial demonstrated that these changes can be used to detect HFrEF with high sensitivity and specificity. Assessment of wave intensity and timing conventionally requires high-frequency, temporally and spatially coincident measurement of changes in P and U or D and U over the cardiac cycle. The practical difficulty of making such measurements accurately and noninvasively limits clinical utility. Here we test simpler methods by using numerical models of wave propagation and data from the clinical trial. We show that methods based on measuring only one of P, D or U can provide good surrogates for the full P-U and D-U methods. The best results were obtained when using measurement of D to assess wave timing. That gave Receiver Operating Characteristics (ROCs) indistinguishable from those based on the full D-U method, with areas under the ROC of up to 0.905 when timing was anchored to the ECG rather than to other waves. Measuring vessel diameter over the cardiac cycle is technically simple and would be a cost-effective way of screening for HFrEF in primary care. Other metrics, similarly measured, might also allow screening for heart failure with preserved ejection fraction (HFpEF). 2026-02-19T22:02:34Z 25 pages, 10 figures Ethan M. Rowland Peter D. Weinberg http://arxiv.org/abs/2602.17553v1 Enhanced distribution of molecules in the brain due to oscillations of the interstitial flow 2026-02-19T17:08:41Z MRI measurements from a decade-old study of the physical properties of brain tissue observed a dynamic, pulsating fluid flow in the interstitial spaces of the brain attributed to the cardiac cycle. The effects of this cyclic flow pattern on the spatial distribution of molecules in the brain are modeled in this paper. The effects of oscillatory flow on the dispersion or volumetric transmission of a molecule that is advected by this flow is modeled by a mechanism hitherto neglected in the literature. An oscillatory random walk model is used to estimate the spread or effective diffusivity due to the oscillatory advection. Then, respiration effects are also estimated and the additional dispersion of molecules due to this are calculated in our model. Our model indicates that the observed oscillatory flow in the interstitial spaces due to cardiac as well as respiratory pulsatility can induce an effective diffusivity when the spread of the molecule is observed over times long compared with a cycle of the oscillation. This would help explain the high-volume transmission within the interstitium or brain parenchyma found in MRI measurements of a marker infused into the cerebrospinal fluid in human subjects that is well above what would be expected. Interstitial spaces should be viewed as a region of dynamic oscillatory flow driven by cardiac and respiratory cycles. This oscillatory flow could result in a significant dispersion of molecules and explain the higher-than-expected effective diffusion suggested in human studies. It may be possible to augment or slow this flow and concomitant spread by applying external forces. 2026-02-19T17:08:41Z 31 pages, 7 figures Raghu Raghavan Richard D. Penn http://arxiv.org/abs/2602.17389v1 Geometric and topological constraints on oral seal formation during infant breastfeeding 2026-02-19T14:13:07Z Breastfeeding efficiency relies on coordinated tongue motion, sustained tissue contact and maintenance of an effective intraoral seal. Current assessments of seal formation mainly use local kinematic descriptors or pressure recordings, which do not capture the global structural continuity of the sealing region. We introduce a systolic geometry based approach in which each sagittal ultrasound frame is modeled as a two dimensional deformable domain bounded by tongue, palate and nipple contours. Global seal continuity is formalized through the shortest closed curve that cannot be contracted to a point because of the overall geometry of the domain. The nipple defines a central region that must be circumferentially enclosed by a contact band to maintain suction. Within this band, closed curves encircling the nipple exactly once can be identified; the shortest of these curves defines a normalized systolic index representing the tightest admissible sealing loop. Simulations of symmetric thinning, localized discontinuities and cyclic perturbations reveal feasibility boundaries separating seal preserving from seal breaking configurations. Notably, admissible encircling curves may transiently disappear even when overall geometric motion remains smooth. By capturing global circumferential continuity that cannot be inferred from local metrics alone, our approach generates testable hypotheses linking the existence and temporal stability of admissible encircling curves to milk transfer efficiency and vacuum stability. Applied to segmented ultrasound data and integrated with pressure measurements, our systolic approach could provide a quantitative framework for objective assessment of seal integrity and longitudinal monitoring of latch stability. 2026-02-19T14:13:07Z 8 pages, 2 figures Arturo Tozzi http://arxiv.org/abs/2511.19547v2 Placental contractions in uncomplicated pregnancies 2026-02-19T14:06:09Z In 2020 we first described placental contractions, and we have now undertaken a study to characterise them and seek features that might automatically separate them from uterine contractions. We recruited 36 healthy pregnant women to undergo magnetic resonance imaging (MRI) between 29 and 42 weeks of pregnancy in a single-centre, prospective, observational study. Participants had fetal ultrasound to confirm normal growth. Dynamic MRI was acquired for between 15 and 32 minutes using respiratory triggered, multi-slice, single shot, gradient echo, echo planar imaging covering the whole uterus. All participants had a live birth of a healthy baby weighing over the 10th centile for gestational age and none developed any associated conditions of placental dysfunction e.g. pre-eclampsia, or severe maternal or fetal villous malperfusion on placental histopathology. Any visible contractions were recorded for all participants who completed their MRI scan and placental contractions occurred in at least 60% of our healthy pregnant population with a median frequency of approximately 2 per hour, and a median duration of 2.4 minutes. Contractions involving a decrease in placental volume of >10% were classified as either placental or uterine by visual observation. Placental contractions occurred more frequently than uterine contractions (p=0.0061), were associated with a larger increase in the surface area of the uterine wall not covered by the placenta (p=0.0015), placental sphericity (p<0.0001) and longer duration (p=0.0151). All contractions led to an increase in the MRI parameter R2* in the placenta. There was large variation both between participants and between contractions from the same individual, in terms of time course and contractions features, with no apparent change across the gestational age range studied, although the largest fractional volume changes were detected at early gestation. 2025-11-24T11:46:34Z Louise Dewick Amy L Turnbull Kate F Walker Nia W Jones George Hutchinson Christopher Bradley Taqwa Ferdous Aisha Razzaque Ruizhe Li Xin Chen Grazziela Figueredo Craig Platt Cesar Peres Penny Gowland http://arxiv.org/abs/2602.04375v2 Angle dependent dose transformer algorithm for fast proton therapy dose calculations 2026-02-18T15:53:42Z Accurate 3D dose calculation for Pencil Beam Scanning Proton Therapy (PBSPT) is typically performed with Monte Carlo (MC) engines, but their runtimes limit adaptive workflows and repeated evaluations. Current deep-learning proton dose engines often require orthogonality between proton rays and the CT grid, forcing computationally expensive beamlet-wise 3D reinterpolation. We propose the Angle-dependent Dose Transformer Algorithm (ADoTA), which eliminates grid rotation by augmenting the model input with a fast analytical beamlet-shape projection that explicitly encodes beam direction. The model was trained on CT data from 108 patients to predict beamlet dose distributions for initial energies of $70$--$270\,\mathrm{MeV}$ over an $80\times110\,\mathrm{mm}^2$ field, and tested on an independent cohort of 50 patients. On the test set, gamma pass rates $(1\%,3\,\mathrm{mm})$ were $99.40\pm0.86\%$ (thorax) and $99.87\pm0.23\%$ (abdomen/pelvis). Single-beamlet inference took $1.72\pm0.8\,\mathrm{ms}$. By avoiding reinterpolation, end-to-end 3D dose computation was reduced by $\approx86\%$ relative to the fastest published reinterpolation-based methods. For full treatment plans, gamma pass rates $Γ(2\%,2\,\mathrm{mm})$ with a 10\% dose cut-off reached $98.4\%$ (lung) and $98.9\%$ (prostate). ADoTA provides an angle-aware deep-learning proton dose engine that preserves MC-level accuracy across heterogeneous anatomies while substantially reducing computational overhead. 2026-02-04T09:52:00Z 27 pages, 15 Figures, 7 Tables Code can be found: https://github.com/Medical-Physics-Technology/adota Mikołaj Stryja Danny Lathouwers Zoltán Perkó http://arxiv.org/abs/2212.00126v3 Proton Computed Tomography Image Reconstruction Based on the Richardson-Lucy Algorithm 2026-02-17T17:08:34Z Proton therapy is an emerging method in cancer therapy. One of the main developments is to increase the accuracy of the Bragg-peak position calculation, which requires more precise relative stopping power (RSP) measurements. A promising choice is the application of proton computed tomography (pCT) systems which takes the images under similar conditions, as they use the same irradiation device and hadron beam for imaging and treatment. A key aim is to develop a precise image reconstruction algorithm for pCT systems to reach their maximal performance. In this work, an iterative image reconstruction algorithm, based on the Richardson-Lucy iteration is proposed for the first time for proton CT image reconstruction. Monte Carlo (MC) simulations of CTP528 and CTP404 phantoms were used to benchmark the proposed method. In the case of an idealized detector setup, using a 1 mm pitch grid, 4.88 lp/cm spatial resolution and 0.66% average RSP uncertainty was achieved. The present method provides a promising proof-of-concept candidate for compromise between accuracy and speed with several further development directions. 2022-11-30T21:28:10Z Gábor Bíró Ákos Sudár Zsófia Jólesz Gábor Papp Gergely Gábor Barnaföldi