https://arxiv.org/api/ewtBtziO4uQDC9qs25VChgOJIJ4 2026-06-22T06:05:59Z 8985 360 15 http://arxiv.org/abs/2602.16991v2 Radiological mapping and uncertainty quantification by a fast Microcanonical Langevin Monte Carlo sampler 2026-03-02T19:01:19Z Radiological mapping plays a critical role in nuclear emergency response and environmental management activities. A radiation image, representing the spatial and intensity distribution of the radioactivity, is reconstructed from the radiation data and the associated contextual information. Typical image reconstruction methods, such as Maximum Likelihood Expectation-Maximization (ML-EM), only provide point estimates of the pixel or voxel activities without associated uncertainties. Here, we apply a new Microcanonical Langevin Monte Carlo (MCLMC) sampler for radiation image reconstruction and uncertainty quantification. The MCLMC sampler properties are first tested with synthetic radiation images. Methods to obtain the radiation distribution estimate and the associated uncertainty from the samples drawn by MCLMC are discussed. Given sufficient measurement statistics, the radiation distribution estimate obtained from MCLMC results closely resembles the ground truth with less risk of over- or under-fitting compared to ML-EM. When MCLMC is run in parallel on a GPU, the samples can converge to the posterior distribution in about 10 seconds for an image with $10^3$--$10^4$ pixels, which is significantly faster than other comparable Markov Chain Monte Carlo (MCMC) samplers. We also tested MCLMC on a dataset from a real distributed source radiological mapping campaign, and the reconstructed results agree well with ground truth. The fast MCLMC sampler therefore enables improved imaging accuracy and prompt uncertainty quantification for reconstructed radiation images, which can better inform decision-making in response to radiological events. 2026-02-19T01:30:44Z 14 pages, 15 figures, 3 tables Lei Pan Jaewon Lee Brian J. Quiter Jakob Robnik Uroš Seljak Jayson R. Vavrek http://arxiv.org/abs/2603.01969v1 Assessing Hemodynamic Impact of Tissue-Engineered Vascular Graft Displacement: Combining Postoperative in vivo Results and Computational Modeling to Improve Surgical Planning 2026-03-02T15:20:40Z Tissue-engineered vascular grafts (TEVG) have shown promise in advancing vascular reconstructions. However, precise in vivo implantation is challenging, and it is unclear how deviations in location and size affect hemodynamics. This study aims to compare preoperative designs and postoperative anatomies of TEVG in an in vivo study to evaluate discrepancies and investigate the impact of graft displacement and size on hemodynamics by virtually simulating implantation scenarios that are informed by in vivo postoperative results. Designed and postoperative geometries of four porcine aortas were compared to measure the mismatch in implantation location and graft shape. These results informed a virtual TEVG implantation study. TEVG location, orientation, and size were varied to investigate the effects on the final aorta shape and hemodynamics. Anastomosis of TEVG was simulated using finite element modeling. Key hemodynamic metrics were obtained from virtual implantations and actual postoperative anatomies using computational fluid dynamics. Our in vivo study showed that TEVGs can experience up to 6.9 mm displacement and a 38 degree rotational shift post-implantation, leading to discrepancies in pressure drop (2.5 mmHg, 50%) and time-averaged wall shear stress (7.2 Pa, 72%) compared to predictions. Virtual anastomosis simulations improved aortic shape predictions by 27.5%. Our results highlight the sensitivity of key hemodynamic metrics to graft implantation location and size mismatch. By quantifying displacement ranges and their impacts during surgery, surgeons can make informed decisions. 2026-03-02T15:20:40Z Seda Aslan Enze Chen Miya Mese-Jones Jacqueline Contento Hidenori Hayashi Keigo Kawaji Joey Huddle Jed Johnson Yue-Hin Loke Mark Fuge Laura Olivieri Thao D Nguyen Narutoshi Hibino Axel Krieger http://arxiv.org/abs/2512.14525v2 Charge collection efficiency of thimble ionization chambers exposed to ultra-high dose per pulse 2026-03-02T14:16:52Z Background: Commercially available ionization chambers (ICs) exposed to ultra-high dose per pulse (UHDP) exhibit deviations from a linear dose response due to volume recombination. Simulation models have been developed to describe the charge collection efficiency (CCE) but focused on parallel-plate ICs. This study aims to measure and simulate the CCE and polarity effect of thimble ICs in UHDP. Methods: The response of two PinPoint3D T31022 (PP3D) and two PinPoint T31023 (PP) ICs was investigated experimentally at the national metrology institute of Germany (PTB). The ICs were irradiated using the UHDP reference electron beam with dose per pulse up to 9.3 Gy for different voltages. A novel finite element code capable of simulating 1D and 2D geometries was developed. Results: Thimble ICs exhibit a pronounced polarization effect when irradiated with UHDP. When the sign of the collected charge is negative, the CCE is larger than when it is positive. The major contribution to the polarity effect can be attributed to the polarity-dependent charge transport and recombination. Experimental and simulated CCE (polarity effect correction factor) agrees within 1.4 % (7.0 %) and 1.6 % (3.2 %) for the PP3D and PP ICs, respectively. The CCE of parallel-plate and thimble ICs is related through a geometrical rule. Conclusions: The PP IC shows greater CCE due to its smaller external radius. The numerical model is able to satisfactory reproduce the actual CCE and polarity effect for these two chambers. At UHDP, thimble ICs should be used with caution due to their large polarity effect. 2025-12-16T15:59:10Z José Paz-Martín Andreas Schüller Marvin Apel Araceli Gago-Arias Juan Pardo-Montero Faustino Gómez http://arxiv.org/abs/2603.01584v1 MR-Compass: Inertial Navigation-Driven Motion Correction for Brain MRI 2026-03-02T08:13:03Z Inertial sensors can track object kinematics, however, unbounded drift from integrating noisy signals makes them impractical for MRI motion correction at millimeter resolution and minute-long scans. We introduce MR-Compass, which exploits the MRI system's static magnetic and gravitational fields to estimate 3-DOF orientation at 2 kHz directly, without integration, eliminating random-walk. The remaining 3-DOF translation is recovered via phase correlation from the MRI data. We experimentally validate the efficacy of the method retrospectively using a 3D radial koosh-ball sequence and prospectively using 2D EPI fMRI during large volunteer motions. MR-Compass followed by phase-correlation achieved a mean accuracy of 0.6$^o$ and 0.4 pixels across all experiments. Image quality improved when motion correction was applied in all volunteer scans for both retrospective and prospective correction cases. MR-Compass was effective in measuring head motion in the MRI scanner with high accuracy at unprecedented sample rates, and enabled both retrospective and prospective reconstruction to improve image quality by aligning the k-space data appropriately and by reducing the motion related artifacts. 2026-03-02T08:13:03Z Musa Tunc Arslan Fatih Calakli Joshua Auger Hongli Fan Alan J Macy Simon K Warfield http://arxiv.org/abs/2603.16892v1 Efficacy of 3D-Printed chitosan-cerium oxide dressings coated with vancomycin-loaded alginate for chronic wounds management 2026-03-01T19:51:45Z Multifunctional wound dressings with antibacterial and antioxidant properties hold significant promise for treating chronic wounds; however, achieving a balance of these characteristics while maintaining biocompatibility is challenging. To enhance this balance, this study focuses on the design and development of 3D-printed chitosan-matrix composite scaffolds, which are incorporated with varying amounts of cerium oxide nanoparticles (0, 1, 3, 5, and 7 wt%) and subsequently coated with a vancomycin-loaded alginate layer. The structure, antibiotic drug delivery kinetics, biodegradation, swelling, biocompatibility, antibacterial, antioxidant, and cell migration behaviors of the fabricated dressings were evaluated in-vitro. The findings reveal that all of the formulations demonstrated a robust antibacterial effect against S. aureus bacterial strains in disk diffusion tests. Furthermore, the dressings containing cerium oxide nanoparticles exhibited proper antioxidant capabilities, with over 78.1% reactive oxygen species (ROS) scavenging efficiency achieved with 7% cerium oxide nanoparticles. The sample containing 5% cerium oxide nanoparticles was identified as the optimal formulation, characterized by the most favorable cell biocompatibility, an ROS scavenging ability of over 73.4%, and the potential to close the wound bed within 24 h. This study highlights that these dressings are promising for managing chronic wounds by preventing infection and oxidative stress in a correct therapeutic sequence. 2026-03-01T19:51:45Z Carbohydrate Polymers, 349 (2025) 123036 Sharareh Shahroudi Amir Parvinnasab Erfan Salahinejad Shaghayegh Abdi Sarah Rajabi Lobat Tayebi 10.1016/j.carbpol.2024.123036 http://arxiv.org/abs/2603.01130v1 A Statistical Framework for Forecasting Cumulative Dose Metrics in Adaptive Radiotherapy 2026-03-01T14:23:08Z Adaptive radiation therapy (ART) seeks to maintain accurate dose delivery by monitoring anatomical changes during treatment and modifying plans accordingly, yet commonly used approaches for estimating cumulative dose rely on heuristic, deterministic assumptions and do not quantify uncertainty in future dose delivery. We present a statistical framework based on simple exponential smoothing (SES) to forecast cumulative dose metrics probabilistically throughout the course of ART. Adapting lead time SES methods from inventory control, we model cumulative dose trajectories and derive closed form prediction intervals and threshold exceedance probabilities for clinically relevant dose metrics. The framework was evaluated using per fraction dose volume histogram data recomputed on daily volumetric imaging for 32 prostate and 19 head and neck patients, allowing assessment of empirical interval coverage, interval width, and adaptive decision support performance. SES based forecasts demonstrated robust coverage probabilities across a range of smoothing parameters and provided appropriately scaled uncertainty estimates for remaining course cumulative dose. In addition, a difference based formulation enabled in course estimation of the probability that an adaptive plan would improve delivered dose metrics relative to the original plan. This SES based forecasting approach offers a computationally efficient and statistically grounded method for anticipating cumulative dose delivery, supporting quantitative, individualized adaptive monitoring and evidence based replanning decisions within routine ART workflows. 2026-03-01T14:23:08Z 21 pages and 5 figures Robert Boyd Wolfgang A. Tomé http://arxiv.org/abs/2603.00736v1 Data-driven Synthesis of Magnetic Resonance Spectroscopy Data using a Variational Autoencoder 2026-02-28T16:52:16Z The development of deep learning methods for magnetic resonance spectroscopy (MRS) is often hindered by limited availability of large, high-quality training datasets. While physics-based simulations are commonly used to mitigate this limitation, accurately modeling all in-vivo signal components remains challenging. In this work, we propose a data-driven framework for synthesizing in-vivo MRS data using a variational autoencoder (VAE) trained exclusively on measured single-voxel spectroscopy data. The model learns a low-dimensional latent representation of complex-valued spectra and enables generation of new samples through latent-space sampling and interpolation. The generative performance of the proposed approach is evaluated using a comprehensive set of complementary analyses, including reconstruction quality, feature-level similarity using low-dimensional embeddings, application-based signal quality metrics, and metabolite quantification agreement. The results demonstrate that the VAE accurately reconstructs dominant spectral patterns and generates synthetic spectra that occupy the same feature space as in-vivo data. In an example application targeting GABA-edited spectroscopy, augmenting limited subsets of transients with synthetic spectra improves signal quality metrics such as signal-to-noise ratio, linewidth, and shape scores. However, the results also reveal limitations of the generative approach, including under-representation of stochastic noise and reduced accuracy in absolute metabolite quantification, particularly for applications sensitive to concentration estimates. These findings highlight both potential and limitations of data-driven MRS synthesis. Beyond the proposed model, this study introduces a structured evaluation framework for generative MRS methods, emphasizing the importance of application-aware validation when synthetic data are used for downstream analysis. 2026-02-28T16:52:16Z Dennis M. J. van de Sande Julian P. Merkofer Sina Amirrajab Mitko Veta Gerhard S. Drenthen Jacobus F. A. Jansen Marcel Breeuwer http://arxiv.org/abs/2602.24139v1 Gestational Stage Prediction from Cervical Tissue Analysis Using Imaging Mueller Polarimetry Data 2026-02-27T16:16:11Z Preterm birth is associated with premature cervical remodeling, yet current clinical assessments cannot detect the underlying microstructural changes in collagen organization. We apply imaging Mueller polarimetry to murine cervical tissue at three gestational stages (early, mid, late) and develop classification methods to predict gestational stage from polarimetric maps. Using Lu-Chipman decomposition, we extract orientation and azimuth local variability maps that capture collagen fiber alignment and disorder. We evaluate two approaches under 20-fold leave-one-out cross-validation: an analytical threshold classifier on mean azimuth local variability, and a lightweight CNN ensemble (approximately 76k parameters) operating on spatially resolved maps. The ensemble achieves 70..0% sample-level accuracy, outperforming the analytical baseline (55.0%), with strong performance on early (71.0%) and late (86.0%) gestation. Spatial prediction maps confirm that classification accuracy is highest in the stroma, where collagen remodeling is most prominent. These results demonstrate that Mueller polarimetry combined with deep learning models can detect gestational collagen remodeling noninvasively, offering a potential pathway toward objective cervical assessment for preterm birth risk. 2026-02-27T16:16:11Z 12 pages, 6 figures. Includes supplementary appendices on dataset and CNN architecture Sooyong Chae Ajmal Ajmal Junzhu Pei Amanda Sanchez Tananant Boonya-ananta Andres Rodriguez Tatiana Novikova Jessica C. Ramella-Roman http://arxiv.org/abs/2602.23536v1 Automated Dose-Based Anatomic Region Classification of Radiotherapy Treatment for Big Data Applications 2026-02-26T22:38:46Z Curation is a significant barrier to using 'big data' radiotherapy planning databases of 100,000+ patients. Anatomic site stratification is essential for downstream analyses, but current methods rely on inconsistent plan labels or target nomenclature, which is unreliable for multi-institutional data. We developed software to automate labeling by inferring anatomic regions directly from dose-volume overlap with deep-learning segmentations, eliminating metadata reliance. The software processes DICOM files in bulk, utilizing deep learning to segment 118 structures (organs, glands, and bones) categorized into six regions: Cranial, Head and Neck, Pelvis, Abdomen, Thorax, Extremity. The 85% and 50% isodose lines are converted to structures to compute organ-specific dose-overlap metrics. Plans are assigned ranked regional labels based on these intersections. The algorithm was refined using 109 expert-labeled cases and validated on 100 consecutive clinical plans. On the 100-plan test dataset, the algorithm achieved 91% Exact Accuracy (matching all expert labels and order), 94% Top-2 Accuracy (matching the top two expert regions regardless of order), and 95% Top-1 Accuracy (matching the primary expert label). The automated workflow demonstrated high accuracy and robustness. The 95% Top-1 Accuracy is particularly significant, as it enables reliable querying of plans based on the primary treatment site. Detailed analysis of the few mismatched cases showed most were treated areas at the border between anatomic regions and were ambiguous between these two regions in a common-sense interpretation. This algorithm provides a scalable, standardized solution for curating the large, multi-institutional datasets required for 'big data' in radiotherapy and provides an important complement to text-based approaches. 2026-02-26T22:38:46Z 16 pages, 3 figures, 2 tables, 1 supplemental table, references arXiv:2411.08876, Justin Hink Yasin Abdulkadir Jack Neylon James Lamb http://arxiv.org/abs/2602.23492v1 Automated Extraction of Unstructured Post-SBRT Toxicity Data from Radiology Reports Using Large Language Models 2026-02-26T20:54:29Z We evaluated the viability of using a Large Language Model (LLM) to extract patient-specific specific toxicity and progression outcomes from unstructured radiology reports. We retrospectively extracted 160 follow-up CT and PET/CT electronic medical record notes for patients treated with lung stereotactic body radiotherapy (SBRT) at our institution from January 2017 through December 2023. Using the Llama 3.3-70-B-Instruct LLM, we engineered prompts to extract four clinical endpoints from each radiology report: locoregional progression, distant progression, radiation-induced fibrosis, and radiation-induced rib fractures. Progression endpoints were classified as yes, no, or maybe, while fibrosis and rib fractures were binary (yes or no). Ground truth labels were defined using two-grader consensus for the 60-note training set, used for prompt development, and a three-grader majority vote for the 100-note test set. LLM performance was evaluated using sensitivity, specificity, and accuracy. As detailed by our evaluation metrics, the strong performance of our methods demonstrates the viability of using prompt-engineered LLMs to extract radiation-toxicities and progression classification from radiology reports. 2026-02-26T20:54:29Z Justin Pijanowski Yakout Mezgueldi Alan Lee Drew Moghanaki Ricky R. Savjani James Lamb http://arxiv.org/abs/2603.13268v1 Crossover Frequency as a Model-Independent Viscoelastic Constant for Soft Tissue Biomechanics 2026-02-26T15:47:52Z Magnetic resonance elastography (MRE) and related elastography techniques are emerging as quantitative diagnostic tools for assessing tissue microstructure and pathology. To determine descriptive parameters of the tissues' properties, a frequency-dependent viscoelastic material model is required, which is calibrated to the measured response in a parameter identification process. However, the selection of this model and the fitting strategy is challenging, since it may influence the identified viscoelastic parameters notably. Here, we address this limitation by proposing the crossover frequency (fc, defined as the frequency at which storage and loss moduli intersect G'(fc) = G''(fc)) as a model-independent viscoelastic constant for soft tissues. Fresh porcine specimens of the corona radiata, the putamen, the thalamus, and the liver were investigated using tabletop MRE and the frequency-dependent viscoelasticity was characterized with a fractional Kelvin-Voigt model. By validating the crossover frequency against the viscoelastic parameters, we demonstrated that the crossover frequency accurately reflects the viscoelastic behavior, independent of the material model or the fitting strategy. Across all samples, fc distinguished brain regions and separated brain from liver tissue by median frequencies of 85Hz (95% CI: 69-269Hz) in the corona radiata, 423Hz (95% CI: 316-575Hz) in the putamen, 426Hz (95% CI: 302-601Hz) in the thalamus and 1174Hz (95% CI: 1074-1300Hz) in the liver (p<0.001). These results suggest that crossover frequencies capture distinct viscoelastic fingerprints without requiring viscoelastic model selection. The crossover frequency may therefore serve as a practical, model-independent biomaterial constant to improve comparability of viscoelastic measurements across elastography studies. 2026-02-26T15:47:52Z Laura Ruhland Jing Guo Ingolf Sack Kai Willner http://arxiv.org/abs/2602.22914v1 Continuous Blood Monitoring with Particle-based Integrated Sensing and Communication (ISAC) 2026-02-26T12:01:18Z Although the circulatory system functions as a continuous source of physiological data, contemporary diagnostics remain bound to intermittent, time-delayed assessments. To resolve this, we present a framework for ubiquitous hematological profiling driven by Integrated Sensing and Communication (ISAC). We demonstrate how electromagnetic signals can be exploited to monitor blood in real-time, effectively converting them into diagnostic tools. We analyze the biological foundations of blood, review existing Complete Blood Count (CBC) and sensing technologies, and detail a novel pipeline for continuous blood monitoring. Furthermore, we discuss the potential applications of deploying these devices to enable real-time CBC and biomarker detection, ultimately revolutionizing how we predict, detect, and manage individual and public health. 2026-02-26T12:01:18Z 11 pages, 2 figures Fatih E. Bilgen Ozgur B. Akan http://arxiv.org/abs/2602.21909v1 Modeling of Human Body-coupled Electric Field Interference in Unshielded Ultra-Low Field MRI 2026-02-25T13:38:04Z Portable ultra-low field MRI (ULF-MRI) systems operated in unshielded environments are susceptible to electromagnetic interference (EMI). Subject presence in the imaging region will lead to substantial noise increases, yet the dominant coupling mechanism remains insufficiently characterized. We develop a lumped-parameter circuit model of the coupled environment-body-receiver system. The model indicates that ambient time-varying electric fields induce a body common-mode potential, which is converted into differential-mode noise through capacitive imbalance between the head and the receive-coil terminals, yielding strong dependence on subject position and geometry. Circuit analysis, simulations, and controlled experiments support the model, with predicted imbalance consistent with measured noise variations. Guided by this mechanism, we implement a capacitive low-impedance bypass to clamp the body potential, achieving an approximately 3.5-fold SNR improvement on a 50 mT prototype. The proposed model offers a compact circuit-based tool for analyzing and mitigating human body-coupled electric-field interference in portable ULF-MRI. 2026-02-25T13:38:04Z Jiali He Yamei Dai Sheng Shen Jiamin Wu Zheng Xu http://arxiv.org/abs/2602.21732v1 Solderable Microcontroller-Integrated E-Textiles using UV-Tape-Assisted Laser Patterning Technique 2026-02-25T09:42:14Z In this study, we developed a UV-tape-assisted laser patterning (UT-Laser) technique that enables the simple transfer-based formation of wiring with line widths below 200 $μ$m onto textile substrates. With the rapid advancement of wearable devices capable of acquiring various types of physiological and environmental information, research on electronic textiles (e-textiles)-in which electronic components are integrated into fabrics and clothing-has progressed considerably. However, integrating high-performance, rigid electronic components onto textiles remains challenging: the diameter of textile fibers limits the formation of fine wiring, making reliable mounting of such components difficult. To address these challenges, we devised the UT-Laser technique, in which thin foil or film materials are laser vector-cut on UV tape, and the adhesive strength is controlled through UV exposure. The unnecessary portions are selectively and collectively peeled away to form fine wiring, which is subsequently transferred onto the textile substrate. This approach enables facile fabrication of fine wiring with line widths below 200 $μ$m on textiles. Furthermore, by forming fine wiring from a flexible copper clad laminate and transferring it onto heat-resistant glass cloth, electronic components can be soldered directly, allowing the fabrication of e-textile devices capable of withstanding more than 10,000 bending cycles. The prototype e-textile device fabricated using the proposed method integrates a microcontroller, USB connector, battery holder, flash memory, inertial measurement unit, and environmental sensors, and successfully acquires data related to stair climbing, respiration, and changes in body temperature during sleep. 2026-02-25T09:42:14Z 16 pages, 4 figures Naoto Tomita Suguru Sato Toshihiro Takeshita Aki Furusawa Jarred Fastier-Wooller Shun Muramatsu Toshihiro Itoh Michitaka Yamamoto http://arxiv.org/abs/2602.21437v1 Respiratory Motion Management in Abdominal MRI: Revisiting the Gap Between Technical Advances and Clinical Translation 2026-02-24T23:30:13Z The inherently slow acquisition speed of MRI makes abdominal imaging highly sensitive to respiratory motion artifacts. Since the early days of MRI, the development of respiratory motion compensation has been an active research topic, and this field has achieved substantial technical progress. Despite these advances, majority of these techniques are not clinically available, and motion management methods used in clinical abdominal MRI today have changed little over the past decades. This observation is striking and points to a significant gap between technical innovation and clinical translation in this area. This review is motivated by this question: why have so many motion management techniques not been adopted into routine clinical workflows? Unlike conventional survey-style reviews that focus on summarizing emerging methods, this article takes a different, and perhaps opposite, perspective to investigate why those technologically sophisticated innovations are misaligned with practical clinical needs. Specifically, we discuss the barriers behind the gap between research advances and clinical practice, clarify the clinical requirements for effective respiratory motion management in abdominal MRI, and highlight research directions with stronger relevance to routine workflows. The review begins with an overview of the clinical impact of respiratory motion in abdominal MRI, followed by a discussion of standard abdominal MRI sequences and their motion sensitivity. We then summarize current clinical strategies and advanced approaches, along with the barriers that hinder their clinical adoption. The article concludes with future directions and broader lessons learned from this translational gap, with the goal of guiding future developments towards improved clinical integration. 2026-02-24T23:30:13Z Li Feng Hersh Chandarana