https://arxiv.org/api/+pZ3w9w/EstNe7e0/LYgMn6YkYY2026-06-22T04:48:42Z898534515http://arxiv.org/abs/2603.19287v1A fully open-source framework for streaming and cloud-processing of low-field MRI data2026-03-08T18:07:22ZPurpose: To present a fully open-source framework for quasi-real-time streaming and cloud-based processing of low-field (LF) MRI data, addressing the growing computational demands of advanced reconstruction and post-processing pipelines in portable and affordable MRI systems. Methods: The proposed framework integrates open-source scanner control software with a network-enabled streaming architecture, allowing for raw data to be transmitted directly from the MRI console to remote compute resources. Cloud-based processing modules support image reconstruction and advanced post-processing, including computationally intensive physics- and learning-based methods, while maintaining compatibility with low-cost on-device control hardware. Results: The system enables continuous acquisition-to-reconstruction workflows in LF-MRI without requiring specialized high-performance console architectures. Selected example applications include deep-learning-based denoising, field-induced distortion correction, and non-Cartesian image reconstruction. Experimental demonstrations show reliable streaming performance. Conclusions: Open-source streaming and cloud-processing provide an effective pathway to overcome the computational limitations of embedded LF-MRI consoles. By decoupling acquisition hardware from intensive reconstruction workloads, the proposed framework supports scalable deployment of advanced algorithms while preserving the affordability and portability that motivate LF-MRI.2026-03-08T18:07:22Z10 pages, 7 figuresT. Guallart-NavalJ. StairsJ. M. AlgarínH. XueJ. BenllochP. BenllochJ. BorregueroJ. ConejeroF. GalveP. García-CristóbalM. LacalleB. LenaL. PorcarS. J. SchiffA. WebbM. HansenJ. Alonsohttp://arxiv.org/abs/2603.07327v1Extending gPET for Multi-Layer PET Simulation2026-03-07T20:17:05ZDepth-of-interaction (DOI) encoding is an effective strategy for reducing parallax error and preserving spatial resolution in positron emission tomography (PET), particularly in compact small-animal scanners. To enable efficient simulation-driven design of DOI-capable systems, we extend the GPU-accelerated Monte Carlo toolkit gPET to support flexible multi-layer detector geometries. The original three-level hierarchical detector model in gPET (panel-module-crystal) was expanded by introducing an intermediate "layer" level, enabling parameterized modeling of stacked scintillator architectures. The photon transport algorithm was correspondingly updated to sample interactions across multiple layers and detector panels while preserving GPU-efficient memory usage. The framework was validated using three scanner configurations: a conventional single-layer ring (H2RSPET-1CL), an aligned split-layer design (H2RSPET-1CL-split), and an offset dual-layer design (H2RSPET-2CL). System performance was evaluated following NEMA NU4-2008 protocols using sensitivity, spatial resolution, and Derenzo phantom simulations with CASToR-based maximum likelihood expectation maximization reconstruction. The H2RSPET-1CL and H2RSPET-1CL-split configurations produced statistically identical hit distributions, while H2RSPET-2CL exhibited the expected offset interaction patterns. Sensitivity of H2RSPET-2CL remained comparable to H2RSPET-1CL, generally within about 2-5 percent, while radial spatial resolution improved substantially (0.8-1.6 mm vs. 1.0-4.2 mm from the center to a 50 mm radial offset). Runtime performance remained essentially unchanged between configurations. The extended gPET framework therefore enables fast and flexible simulation of multi-layer PET detectors and supports efficient optimization of DOI-enabled PET system designs.2026-03-07T20:17:05ZSatzhan SitmukhambetovJunwei DuMingwu JinYujie Chihttp://arxiv.org/abs/2512.19676v3Efficient Vision Mamba for MRI Super-Resolution via Hybrid Selective Scanning2026-03-07T16:43:29ZBackground: High-resolution MRI is critical for diagnosis, but long acquisition times limit clinical use. Super-resolution (SR) can enhance resolution post-scan, yet existing deep learning methods face fidelity-efficiency trade-offs. Purpose: To develop a computationally efficient and accurate deep learning framework for MRI SR that preserves anatomical detail for clinical integration. Materials and Methods: We propose a novel SR framework combining multi-head selective state-space models (MHSSM) with a lightweight channel MLP. The model uses 2D patch extraction with hybrid scanning to capture long-range dependencies. Each MambaFormer block integrates MHSSM, depthwise convolutions, and gated channel mixing. Evaluation used 7T brain T1 MP2RAGE maps (n=142) and 1.5T prostate T2w MRI (n=334). Comparisons included Bicubic interpolation, GANs (CycleGAN, Pix2pix, SPSR), transformers (SwinIR), Mamba (MambaIR), and diffusion models (I2SB, Res-SRDiff). Results: Our model achieved superior performance with exceptional efficiency. For 7T brain data: SSIM=0.951+-0.021, PSNR=26.90+-1.41 dB, LPIPS=0.076+-0.022, GMSD=0.083+-0.017, significantly outperforming all baselines (p<0.001). For prostate data: SSIM=0.770+-0.049, PSNR=27.15+-2.19 dB, LPIPS=0.190+-0.095, GMSD=0.087+-0.013. The framework used only 0.9M parameters and 57 GFLOPs, reducing parameters by 99.8% and computation by 97.5% versus Res-SRDiff, while outperforming SwinIR and MambaIR in accuracy and efficiency. Conclusion: The proposed framework provides an efficient, accurate MRI SR solution, delivering enhanced anatomical detail across datasets. Its low computational demand and state-of-the-art performance show strong potential for clinical translation.2025-12-22T18:53:13ZMojtaba SafariShansong WangVanessa L WildmanMingzhe HuZach EidexChih-Wei ChangErik H MiddlebrooksRichard L. J QiuPretesh PatelAshesh B. JaniHui MaoZhen TianXiaofeng Yanghttp://arxiv.org/abs/2603.07103v1Ultra-Sharp Upright Photon Radiotherapy via Low Energy Extended Distance: An Alternative to FLASH for high flux Sources2026-03-07T08:27:09ZStandard 6 megavolt (MV) radiotherapy is limited by source size and secondary electron range to minimum radiological penumbra widths of ~2-3 mm. This study investigates sharper beams via upright radiotherapy with lower energies and extended source-to-patient distances. A 2.5 MV beam from a clinical linac was delivered at a 4 m source-to-phantom distance (2.5 MV-ED). Lateral profiles and percent depth doses were measured in a solid water phantom with radiochromic film and an ion chamber. These single beam measurements were used to benchmark TOPAS Monte Carlo simulations. The validated 2.5 MV-ED model was then used to simulate upright deliveries with a conical beam geometry. These simulations were compared against equivalent plans generated for standard 6 MV-FFF coplanar deliveries at 1 m from the source. The 2.5 MV-ED single 28x28 mm^2 beam produced a measured 80%-20% penumbra of 1.0 +-0.1 mm, compared to 2.4 mm Jaw-defined penumbra for a standard 6MV-FFF beam. The doses at 10 cm depth were 52% vs. 56%, and the surface doses were 22% vs. 38% for the 2.5MV-ED and standard 6 MV-FFF respectively. Conical geometry Monte-Carlo simulations using the 2.5 MV-ED beams demonstrated significantly sharper composite dose fall-off in all cardinal directions compared to coplanar 6MV-FFF plans. For a spatially fractionated lattice example plan with 5 mm diameter high dose spheres, the 2.5 MV-ED conical approach achieved a peak-to-valley dose ratio of 4.5-5.2, compared to the 2.6-2.9 achievable with a standard 6 MV-FFF clinical system. Low-energy, extended-distance photon beams can provide sharper penumbra and lower surface dose, while maintaining comparable depth-dose penetration as standard 6 MV setups. Combined with upright patient setups, ultra-sharp dose distributions with enhanced treatment conformity, reduced toxicity, and higher-fidelity dose modulation are possible.2026-03-07T08:27:09ZLloyd E Kamole GhomsiClinton GibsonVeng-Jean HengRamish M AshrafLawrie Skinnerhttp://arxiv.org/abs/2603.06496v1Rotation-invariant graph message passing enables acquisition protocol generalisation in learning-based brain microstructure estimation2026-03-06T17:29:14ZEstimating brain microstructure has important applications in medicine and neuroscience. Diffusion-weighted magnetic resonance imaging enables measuring microstructure \textit{in vivo}. Conventional biophysical model fitting can be accurate but is slow and impractical for time-critical clinical use, where machine learning can offer a potential route to rapid estimation. We address the problem of microstructure estimation under arbitrary acquisition protocols where most existing learning-based methods fail due to protocol assumptions, requiring retraining when the protocol changes. We present a graph neural network that represents input data as a point cloud in the 3D space where diffusion-weighted measurements are made and performs rotation-invariant message passing with permutation-invariant pooling, producing fixed-size embeddings that encode microstructure. The inductive biases of our relatively small model were guided by the underlying physics and symmetries of the problem rather than by generic model architectures. Trained on randomised simulated data, our model demonstrates domain generalisation, accurately estimating microstructure from data with unseen real-world protocols without retraining. This approach represents a step towards a "train once, deploy anywhere" architecture, bringing rapid learning-based microstructure mapping closer to clinical deployment.2026-03-06T17:29:14ZLeevi KerkeläHui Zhanghttp://arxiv.org/abs/2603.06338v1AI End-to-End Radiation Treatment Planning Under One Second2026-03-06T14:45:44ZArtificial intelligence-based radiation therapy (RT) planning has the potential to reduce planning time and inter-planner variability, improving efficiency and consistency in clinical workflows. Most existing automated approaches rely on multiple dose evaluations and corrections, resulting in plan generation times of several minutes. We introduce AIRT (Artificial Intelligence-based Radiotherapy), an end-to-end deep-learning framework that directly infers deliverable treatment plans from CT images and structure contours. AIRT generates single-arc VMAT prostate plans, from imaging and anatomical inputs to leaf sequencing, in under one second on a single Nvidia A100 GPU. The framework includes a differentiable dose feedback, an adversarial fluence map shaping, and a plan generation augmentation to improve plan quality and robustness. The model was trained on more than 10,000 intact prostate cases. Non-inferiority to RapidPlan Eclipse was demonstrated across target coverage and OAR sparing metrics. Target homogeneity (HI = 0.10 $\pm$ 0.01) and OAR sparing were similar to reference plans when evaluated using AcurosXB. These results represent a significant step toward ultra-fast standardized RT planning and a streamlined clinical workflow.2026-03-06T14:45:44ZSimon ArberetRiqiang GaoMartin KrausFlorin C. GhesuWilko VerbakelMamadou DialloAnthony MagliariVenkatesan KaruppusamySushil BeriwalREQUITE ConsortiumAli KamenDorin Comaniciuhttp://arxiv.org/abs/2603.06314v1Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients2026-03-06T14:16:38ZProbabilistic evaluation improves the trade-off between target coverage and OAR sparing in IMPT but remains computationally demanding. This study proposes sparse probabilistic evaluation (SPE), a computationally efficient approach integrated into a clinical TPS.
Clinical plans of 20 IMPT HNC patients treated in 2024 were included. SPE used a predefined setup and range error grid with Monte Carlo computed dose distributions. Two grid settings were evaluated: the maximum error Emax (3$σ$ or 4$σ$) and the number of setup error points nsetup (7, 33, 123). Accuracy and duration of SPE with each grid were evaluated in the calibration group (5 patients). 1000 treatments with normally distributed random ($σ$ = 1 mm) and systematic ($σ$ = 0.92 mm) setup and range ($σ$ = 1.5%) errors were simulated. The dose distribution of the nearest error point in the grid was assigned to each fraction. Probability distributions derived from SPE were compared with those from a reference based on 35,000 Monte Carlo calculations. The found optimal grid (Emax = 3$σ$, nsetup = 33) was applied to the validation group (15 patients).
Accuracy of SPE in the calibration group increased significantly as the number of error points increased from 7 (tavg = 2 minutes) to 33 (tavg = 9 minutes), with no further improvement between 33 and 123 (tavg = 27 minutes) error points. Increasing Emax only improved accuracy for values above the 98th percentile. Applying SPE to the validation group resulted in median errors of 0.02 Gy RBE (range:-0.11 to 0.07) for the 10th percentile of the D99.8%, CTV distribution and 0.0 Gy RBE (range:-0.14 to 0.23) for the 95th percentile of the D0.03cc,SpinalCord Core distribution.
Sparse probabilistic evaluation achieves sufficient accuracy while requiring clinically acceptable computation times, paving the way for probabilistic evaluation in clinical practice.2026-03-06T14:16:38ZJenneke I. de JongSteven J. M. HabrakenAlbin FredrikssonJohan SundströmErik EngwallSebastiaan BreedveldMischa S. Hoogemanhttp://arxiv.org/abs/2603.05796v1CBCT-Based Synthetic CT Generation Using Conditional Flow Matching Model2026-03-06T01:04:47ZDaily or weekly cone-beam computed tomography (CBCT) is employed in image-guided radiotherapy (IGRT) for precise patient alignment. However, its clinical utility in quantitative tasks is hindered by severe artifacts and inaccurate Hounsfeld unit (HU). It is essential to enhance CBCT image quality to a level comparable with that of conventional CT scans. This study proposed a conditional flow matching model that gradually transforms a sample from normal distribution to the corresponding CT sample conditioned on the input CBCT image. The proposed model was trained using CBCT and deformed planning CT (dpCT) image pairs in a supervised learning scheme. The feasibility of the conditional flow matching model was verified using studies of brain, head-and-neck (HN), and lung patients. The quantitative performance was evaluated using three metrics, including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). The proposed flow matching model was also compared to other flow matching and diffusion-based generative models for sCT generation. The proposed flow matching model effectively reduced multiple types of artifacts on CBCT images in all the studies. In the study of brain patient, the MAE, PSNR, and NCC of the sCT were improved to 26.02 HU, 32.35 dB, and 0.99, respectively, from 40.63 HU, 27.87 dB, and 0.98 on the CBCT images. In the study of HN patient, the metrics were improved to 33.17 HU, 28.68 dB, 0.98 from 38.99 HU, 27.00 dB, 0.98. In the lung patient study, the metrics were 25.09 HU, 32.81 dB, 0.99 and 32.90 HU, 30.48 dB, 0.98 for sCT and CBCT, respectively. The proposed conditional flow matching model effectively synthesizes high-quality CT-like images from CBCT, achieving accurate HU representation and artifact reduction. This enables more reliable organ segmentation and dose calculation in CBCT-guided online ART workflows.2026-03-06T01:04:47ZJunbo PengHuiqiao XieTonghe WangXiangyang TangXiaofeng Yanghttp://arxiv.org/abs/2603.05247v1ICHOR: A Robust Representation Learning Approach for ASL CBF Maps with Self-Supervised Masked Autoencoders2026-03-05T15:01:11ZArterial spin labeling (ASL) perfusion MRI allows direct quantification of regional cerebral blood flow (CBF) without exogenous contrast, enabling noninvasive measurements that can be repeated without constraints imposed by contrast injection. ASL is increasingly acquired in research studies and clinical MRI protocols. Building on successes in structural imaging, recent efforts have implemented deep learning based methods to improve image quality, enable automated quality control, and derive robust quantitative and predictive biomarkers with ASL derived CBF. However, progress has been limited by variable image quality, substantial inter-site, vendor and protocol differences, and limited availability of labeled datasets needed to train models that generalize across cohorts. To address these challenges, we introduce ICHOR, a self supervised pre-training approach for ASL CBF maps that learns transferable representations using 3D masked autoencoders. ICHOR is pretrained via masked image modeling using a Vision Transformer backbone and can be used as a general-purpose encoder for downstream ASL tasks. For pre-training, we curated one of the largest ASL datasets to date, comprising 11,405 ASL CBF scans from 14 studies spanning multiple sites and acquisition protocols. We evaluated the pre-trained ICHOR encoder on three downstream diagnostic classification tasks and one ASL CBF map quality prediction regression task. Across all evaluations, ICHOR outperformed existing neuroimaging self-supervised pre-training methods adapted to ASL. Pre-trained weights and code will be made publicly available.2026-03-05T15:01:11ZXavier Beltran-UrbanoYiran LiXinglin ZengKatie R. JobsonManuel TasoChristopher A. BrownDavid A. WolkCorey T. McMillanIlya M. NashrallahPaul A. YushkevichZe WangJohn A. DetreSudipto Doluihttp://arxiv.org/abs/2505.19146v3Design of a Wearable Parallel Electrical Impedance Imaging System for Healthcare2026-03-05T13:01:13ZA wireless wearable Electrical Impedance Tomography (EIT) system has been developed utilizing the AD5933 chip to achieve real-time imaging of lung respiration. The system employs a voltage excitation method tailored to human impedance characteristics, injecting current by applying a known voltage and measuring the resulting current through the body. Additionally, specific measures have been implemented to effectively suppress signal oscillations and leakage currents caused by parasitic capacitances. To enhance data acquisition speed, the system employs five parallel AD5933 units, with multiple techniques implemented to ensure high synchronization during simultaneous measurements. Performance testing shows that the system achieves a signal-to-noise ratio greater than 50 dB, a relative standard deviation below 0.3%, and a reciprocity error under 0.8%. Imaging experiments using a water tank phantom, human lungs during breathing, and a resting human calf further demonstrate that this portable EIT system can accurately measure biological tissues with high precision and low cost.2025-05-25T13:46:18ZBowen LiZekun ChenXuefei ChenLuhao ZhangShili Lianghttp://arxiv.org/abs/2603.04233v1Continuous Ventricular Volumetric Quantification in Patients with Arrhythmias using Real-Time 3D CMR-MOTUS2026-03-04T16:15:44ZConventional cardiovascular magnetic resonance (CMR) cine imaging relies on binning multiple heartbeats into a single cardiac cycle, which fails in arrhythmic patients where beat-to-beat variability causes motion artifacts and loss of functional information. Real-time 2D imaging captures individual beats but lacks volumetric coverage for mapping arrhythmic cardiac dynamics. We present a 3D real-time motion-field reconstruction method enabling continuous volumetric assessment in patients with premature ventricular contractions (PVCs) using a free-running CMR protocol. CMR-MOTUS was extended to jointly reconstruct real-time 3D motion fields and a motion-corrected reference image from continuous, ungated, non-breath-held data acquired with a variable-density Cartesian OPRA trajectory. Beat-to-beat ejection fraction (EF) was computed by propagating a single segmentation through all frames using the reconstructed motion fields. The method was validated on a cardiac motion phantom and tested in four healthy volunteers and four PVC patients. Phantom EF closely matched ground truth (22.1 +/- 0.6 percent vs. 21.9 percent). In healthy volunteers, EF values agreed with 2D references and showed narrow distributions reflecting physiological consistency. In PVC patients, EF distributions were bimodal, with the lower mode corresponding to PVC beats with markedly reduced EF. ECG confirmed alignment between EF irregularities and PVC episodes. These results show that 3D real-time motion-field reconstruction enables continuous beat-to-beat volumetric quantification in arrhythmia, revealing functional heterogeneity that conventional binning obscures. The bimodal EF distributions capture the true hemodynamic impact of PVCs and may provide clinically relevant metrics for monitoring and treatment evaluation.2026-03-04T16:15:44ZThomas E. OlaussonMaarten L. TerpstraRizwan AhmadEdwin VersteegCasper BeijstYuchi HanMarco GuglielmoBirgitta K. VelthuisCornelis van den BergAlessandro Sbrizzihttp://arxiv.org/abs/2603.03916v1A review of ventral hernia biomechanics2026-03-04T10:24:45ZDespite advancements in surgical techniques, hernia recurrence rates remain high, underscoring the need for improved understanding of abdominal wall behaviour. While surgeons are aware of many factors contributing to hernia occurrence (e.g obesity, smoking, surgical technique or site infection), it would be of interest to consider it as a biomechanical pathology. Indeed, an abdominal hernia arises from an imbalance between abdominal wall deformability and applied forces. This review article discusses how biomechanics offer a quantitative framework for assessing healthy and damaged tissue behaviour, guiding personalised surgical strategies throughout the pre-, intra-, and post-operative periods. The abdominal wall is a dynamic, load-bearing structure, continuously subjected to intra-abdominal pressure and mechanical stress. Its biomechanical properties, including elasticity and resistance to loading forces, dictate its function and response to surgical intervention. The linea alba is the stiffest component experiencing the highest stress, while the abdominal wall's anisotropic nature influences deformation patterns. Various experimental and computational methods enable biomechanical characterisation. Hernias represent mechanical failures at anatomical weak points. While surgeons qualitatively evaluate abdominal wall's biomechanics by estimating deformation and closure forces, functional imaging (elastography, dynamic acquisitions) could provide objective biomechanical insights. Hernia formation alters abdominal wall biomechanics, inducing greater mobility and elasticity. Surgical repair fundamentally alters the biomechanics of the abdominal wall. The choice of defect's suturing technique, mesh properties, placement, overlap and fixation methods (e.g. suture, tacks) significantly influence mechanical outcomes. Surgical repair tends to restore physiological biomechanics by re-establishing force transmission and hernia-induced excessive mobility. Suturing techniques, mesh selection and placement influence mechanical outcomes. However, optimal results require implants with mechanical properties mimicking native tissue. Lightweight meshes (<70 g/m2) placed in a retrorectus position, combined with a small-bite suture technique, have been associated with lower recurrence rates and improved post-operative function. By bridging biomechanics with surgical practice, this review highlights how mechanical principles shape hernia formation, diagnosis, and repair. A deeper integration of biomechanical principles into surgical decision-making could refine hernia management and lead to patient-specific, mechanics-informed strategies. For surgeons, this knowledge is not just academic - it is practical and can make a difference to patient outcomes.2026-03-04T10:24:45ZJournal of the mechanical behavior of biomedical materials, In press, pp.107159Victoria JoppinLBA UMR T24, CRMBMCatherine MassonLBA UMR T24David BendahanCRMBMThierry BegeLBA UMR T24http://arxiv.org/abs/2603.03912v1Fast proton transport and neutron production in proton therapy using Fourier neural operators2026-03-04T10:19:29ZObjective: Real-time adaptive proton range verification systems based on produced neutrons require accurate information on their non-isotropic momentum distributions within short times, for which Monte Carlo (MC) methods are too computationally expensive. We present a surrogate model based on Fourier Neural Operators (FNO) for fast prediction of angle- and energy-resolved proton transport and neutron production within proton therapy.
Approach: We treat the irradiated phantom and the proton beam's state as depth-evolving series, respectively of different materials, and of spatial, angular and energy phase space density distributions. The task is solved auto-regressively by learning changes in the distributions of protons and those of produced neutrons. For training and evaluation, two datasets of 47 MC simulations featuring different primary intensities were produced. Simulated geometries were extracted from a thoracic CT scan as series of laterally homogeneous materials.
Main Results: An average relative $L^2$ discrepancy of 0.067 and 0.137 was achieved by the predicted proton and neutron distributions, respectively. This corresponded to an average gamma passing rate in the spatial distributions of 99.95$\%$ and 99.40$\%$. Training with higher primary intensities led to improvements between 12$\%$ and 30$\%$ in density metrics. Inference over depths of 40 cm at a resolution of 0.5 mm required on average 23.17 s per beam.
Significance: The proposed proton beam surrogate generates accurate spatial and momentum distributions of neutrons at MC-level accuracy within seconds, while demonstrating robust generalization with respect to irradiated geometry and beam characteristics. This approach can be used for prototyping and operation of range verification systems, other tasks such as neutron dose estimation, and can be extended to include other kinds of secondary emissions.2026-03-04T10:19:29Z25 pages, 12 figures. When specified, figures can be visualized as video using suitable PDF readersFrancesco BlangiardiFraunhofer ENASTechnical University ChemnitzHunter N. RatliffWestern Norway University of Applied SciencesFabian TeichertFraunhofer ENASTechnical University ChemnitzKristian Smeland Ytre-HaugeUniversity of BergenJan LangerFraunhofer ENASIlker MericWestern Norway University of Applied Scienceshttp://arxiv.org/abs/2603.03832v1Non-Invasive Reconstruction of Cardiac Activation Dynamics Using Physics-Informed Neural Networks2026-03-04T08:33:16ZCardiac arrhythmogenesis is governed by complex electromechanical interactions that are not directly observable in vivo, motivating the development of non-invasive computational approaches for reconstructing three-dimensional activation dynamics. We present a physics-informed neural network framework for recovering cardiac activation patterns, active tension propagation, deformation fields, and hydrostatic pressure from measurable deformation data in simplified left ventricular geometries. Our approach integrates nonlinear anisotropic constitutive modeling, heterogeneous fiber orientation, weak formulations of the governing mechanics, and finite-element-based loss functions to embed physical constraints directly into training.
We demonstrate that the proposed framework accurately reconstructs spatiotemporal activation dynamics under varying levels of measurement noise and reduced spatial resolution, while preserving global propagation patterns and activation timing. By coupling mechanistic modeling with data-driven inference, this method establishes a pathway toward patient-specific, non-invasive reconstruction of cardiac activation, with potential applications in digital phenotyping and computational support for arrhythmia assessment.2026-03-04T08:33:16ZNathan DermulHans Dierckxhttp://arxiv.org/abs/2602.11497v2End-to-End Differentiable Photon Counting CT2026-03-02T19:55:42ZQuantitative imaging is an important feature of spectral X-ray and CT systems, especially photon-counting CT (PCCT) imaging systems, which is achieved through material decomposition (MD) using spectral measurements. In this work, we present a novel framework that makes the PCCT imaging chain end-to-end differentiable (differentiable PCCT), with which we can leverage quantitative information in the image domain to enable cross-domain learning and optimization for upstream models. Specifically, the material decomposition from maximum-likelihood estimation (MLE) was made differentiable based on the Implicit Function Theorem and inserted as a layer into the imaging chain for end-to-end optimization. This framework allows for an automatic and adaptive solution of a wide range of imaging tasks, ultimately achieving quantitative imaging through computation rather than manual intervention. The end-to-end training mechanism effectively avoids the need for direct-domain training or supervision from intermediate references as models are trained using quantitative images. We demonstrate its applicability in two representative tasks: correcting detector energy bin drift and training an object scatter correction network using cross-domain reference from quantitative material images.2026-02-12T02:46:01ZSen WangYirong YangJooho LeeGrant M. StevensAdam S. Wang