https://arxiv.org/api/Yeu55SGafmG0Ewm6KbL9Ngw/1902026-06-22T03:35:44Z898533015http://arxiv.org/abs/2603.13007v1Accelerating Stroke MRI with Diffusion Probabilistic Models through Large-Scale Pre-training and Target-Specific Fine-Tuning2026-03-13T14:13:53ZPurpose: To develop a data-efficient strategy for accelerated MRI reconstruction with Diffusion Probabilistic Generative Models (DPMs) that enables faster scan times in clinical stroke MRI when only limited fully-sampled data samples are available.
Methods: Our simple training strategy, inspired by the foundation model paradigm, first trains a DPM on a large, diverse collection of publicly available brain MRI data in fastMRI and then fine-tunes on a small dataset from the target application using carefully selected learning rates and fine-tuning durations. The approach is evaluated on controlled fastMRI experiments and on clinical stroke MRI data with a blinded clinical reader study.
Results: DPMs pre-trained on approximately 4000 subjects with non-FLAIR contrasts and fine-tuned on FLAIR data from only 20 target subjects achieve reconstruction performance comparable to models trained with substantially more target-domain FLAIR data across multiple acceleration factors. Experiments reveal that moderate fine-tuning with a reduced learning rate yields improved performance, while insufficient or excessive fine-tuning degrades reconstruction quality. When applied to clinical stroke MRI, a blinded reader study involving two neuroradiologists indicates that images reconstructed using the proposed approach from $2 \times$ accelerated data are non-inferior to standard-of-care in terms of image quality and structural delineation.
Conclusion: Large-scale pre-training combined with targeted fine-tuning enables DPM-based MRI reconstruction in data-constrained, accelerated clinical stroke MRI. The proposed approach substantially reduces the need for large application-specific datasets while maintaining clinically acceptable image quality, supporting the use of foundation-inspired diffusion models for accelerated MRI in targeted applications.2026-03-13T14:13:53ZYamin ArefeenSidharth KumarSteven WarachHamidreza SaberJonathan Tamirhttp://arxiv.org/abs/2603.12975v1Mixed Ion Beams Enable Simultaneous Treatment and Real-Time Imaging in Carbon Ion Therapy2026-03-13T13:21:47ZCarbon ion therapy is one of the most advanced forms of radiotherapy, promising improved efficacy against resistant cancers. However, the high precision offered by the carbon ion Bragg peak requires precise knowledge of the beam range inside the patient. We report the first experimental realization of range monitoring and portal imaging with a mixed ion beam, where carbon ions are treating the tumor while helium ions simultaneously accelerated to the same velocity fully traverse the patient and provide treatment feedback. Using the GSI synchrotron, a beam of 12C3+ and 4He1+ ions is accelerated, exploiting their nearly identical charge-to-mass ratios. Stable extraction with controlled helium fractions down to 7% is demonstrated. Beam characterization reveals that the helium ion Bragg peak can be cleanly separated from the carbon ion fragment background which enables accurate detection of sub-millimeter Bragg peak displacements. Mixed-beam radiographs of a lung-cancer-like phantom offer target position detection to better than 0.5 mm accuracy. This establishes mixed beams as a powerful modality for real-time image guidance in carbon ion therapy, uniquely providing simultaneous treatment delivery, range probing, and portal imaging. By overcoming range uncertainty inside the patient, mixed beams will enable to fully exploit the precision of carbon ion therapy.2026-03-13T13:21:47ZLennart VolzRonja HetzelMaximilian DickMaria Chiara MartireGuangru LiChristoph SchuySali BallouzMikael SimardSaad ShaikhCharles-Antoine Collins-FeketeTim WagnerMichael GalonskaAndrii PatushenkoRalph HollingerFabio MaimoneJens StadlmannLars BozykDavid OndrekaSimone SavazziMarco PulliaMarco DuranteChristian Graeffhttp://arxiv.org/abs/2603.11316v1MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors2026-03-11T21:23:52ZMagnetic Resonance Fingerprinting (MRF) and other highly accelerated transient-state parameter mapping techniques enable simultaneous quantification of multiple tissue properties, but often suffer from aliasing artifacts due to compressed sampling. Incorporating spatial image priors can mitigate these artifacts, and deep learning has shown strong potential when large training datasets are available. However, extending this paradigm to MRF-type sequences remains challenging due to the scarcity of quantitative imaging data for training. Can this limitation be overcome by leveraging sources of training data from clinically-routine weighted MRI images? To this end, we introduce MRI2Qmap, a plug-and-play quantitative reconstruction framework that integrates the physical acquisition model with priors learned from deep denoising autoencoders pretrained on large multimodal weighted-MRI datasets. MRI2Qmap demonstrates that spatial-domain structural priors learned from independently acquired datasets of routine weighted-MRI images can be effectively used for quantitative MRI reconstruction. The proposed method is validated on highly accelerated 3D whole-brain MRF data from both in-vivo and simulated acquisitions, achieving competitive or superior performance relative to existing baselines without requiring ground-truth quantitative imaging data for training. By decoupling quantitative reconstruction from the need for ground-truth MRF training data, this framework points toward a scalable paradigm for quantitative MRI that can capitalize on the large and growing repositories of routine clinical MRI.2026-03-11T21:23:52ZMohammad GolbabaeeMatteo CenciniCarolin PirklMarion MenzelMichela TosettiBjoern Menzehttp://arxiv.org/abs/2512.24514v2A novel Boltzmann equation solver for calculation of dose and fluence spectra distributions for proton beam therapy2026-03-11T20:58:23ZThe claim that Monte Carlo is the most accurate method is a case of misattributed credit. This claim is based on experience with advanced systems MCNPX, Geant4 and EGS. These systems achieve remarkable performance because they use most accurate physics, not because they use random numbers. The latter simplifies algorithms, but contaminates the solution with random noise. Currently prevalent fast Monte Carlo algorithms retain this worst part while achieving high computing speed at the expense of the best part- accurate physics. We employ an opposite strategy. We develop a Boltzmann solver for protons that retains unchanged the physics of most advanced Monte Carlo systems. We eliminate random noise, because our solution method is deterministic. Our method is also applicable to heavier ions, helium and carbon, for example.
Results of the study provide a foundation for achieving a high computing speed with uncompromised accuracy in proton treatment planning systems.2025-12-30T23:24:52ZOleg N VassilievRadhe Mohanhttp://arxiv.org/abs/2603.08751v2Exploring Strategies for Personalized Radiation Therapy Part IV: An Interaction-Picture Approach to Quantify the Abscopal Effect2026-03-11T15:03:39ZWe revisit the controversial "abscopal" effect in the context of Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR). By allowing long interval between fractions, PULSAR may enhance systemic immune activation and increase the likelihood of abscopal responses compared with conventional daily fractionation. To quantify treatment-induced effects, we introduce an interaction-picture transformation adapted from quantum mechanics, which separates intrinsic tumor growth from radiation and immune-mediated perturbations. In this preliminary study, we tested this method to two preclinical bilateral tumor models (4T1 and MC38). Our model provides a quantitative measure of the interaction strength between primary and secondary tumors at the individual level, capturing dynamics over time rather than relying solely on cohort averages. This approach frames the abscopal effect as a continuous, stochastic phenomenon rather than a binary response. The framework is flexible for future studies, particularly in concurrent radiation and immunotherapy with PULSAR, where different radiation doses and fractionation schedules can be compared, and immune checkpoint inhibitors (ICIs) can be incorporated to further enhance systemic anti-tumor immunity. The framework can also help us make cross-study comparison of abscopal effects and standardizes the reporting of abscopal magnitude beyond simple statistical significance.2026-03-07T00:17:51ZHao PengLaurentiu PopKai JiangFaya ZhangDebabrata SahaRaquibul HannanRobert Timmermanhttp://arxiv.org/abs/2603.10364v1Information-Theoretic Spectroscopy: Universal Sparsity of Extinction Manifold and Optimal Sensing across Scattering Regimes2026-03-11T03:25:02ZThe inverse reconstruction of material properties from optical extinction efficiency (Qext) is constrained by the high-dimensional nature of Mie scattering. We demonstrate that the Qext manifold possesses an intrinsic, physics-governed sparsity universal across dielectric materials. By analyzing the spectral topology of a diverse polymer library, we identify a critical Information Bottleneck at the onset of the Mie transition (r approx 0.1 um), where a peak in spectral entropy signifies a fundamental limit on signal compressibility. While the Fast Fourier Transform (FFT) is conventionally used for spectral analysis, we show it is physically mismatched for this domain; its periodic boundary assumptions induce spectral leakage that forces a massive basis expansion to resolve Mie ripples. Conversely, the Discrete Cosine Transform (DCT) mirrors the non-periodic geometry of extinction profiles, uncovering inherent compressibility by capturing over 90% of signal energy using fewer than 10 harmonic modes. Even at the Mie bottleneck, the DCT maintains a 12-fold compression advantage over the FFT at a 99% energy threshold. Notably, while both bases converge to identical error floors for a fixed energy threshold, the DCT achieves this fidelity with significantly lower hardware overhead. Stress-testing under 10% additive Gaussian noise confirms the Information Bottleneck is spatially and structurally invariant, proving this complexity peak is a fundamental physical constant of the manifold. By mapping this sparsity onto a compressed sensing architecture, we resolve a 2.5-20 um spectral range using between 22 and 170 sensors: enabling a 51%-94% reduction in hardware complexity that breaks the traditional Nyquist sampling limit (350 sensors) for high-fidelity clinical and remote sensing applications.2026-03-11T03:25:02Z34 pages, 10 figuresProity Nayeeb Akbarhttp://arxiv.org/abs/2601.09006v2GOUHFI 2.0: A Next-Generation Toolbox for Brain Segmentation and Cortex Parcellation at Ultra-High Field MRI2026-03-10T20:48:45ZUltra-High Field MRI (UHF-MRI) is increasingly used in large-scale neuroimaging studies, yet automatic brain segmentation and cortical parcellation remain challenging due to signal inhomogeneities, heterogeneous contrasts and resolutions, and the limited availability of tools optimized for UHF data. Standard software packages such as FastSurferVINN and SynthSeg+ often yield suboptimal results when applied directly to UHF images, thereby restricting region-based quantitative analyses. To address this need, we introduce GOUHFI 2.0, an updated implementation of GOUHFI that incorporates increased training data variability and additional functionalities, including cortical parcellation and volumetry.
GOUHFI 2.0 preserves the contrast- and resolution-agnostic design of the original toolbox while introducing two independently trained 3D U-Net segmentation tasks. The first performs whole-brain segmentation into 35 labels across contrasts, resolutions, field strengths and populations, using a domain-randomization strategy and a training dataset of 238 subjects. Using the same training data, the second network performs cortical parcellation into 62 labels following the Desikan-Killiany-Tourville (DKT) protocol.
Across multiple datasets, GOUHFI 2.0 demonstrated improved segmentation accuracy relative to the original toolbox, particularly in heterogeneous cohorts, and produced reliable cortical parcellations. In addition, the integrated volumetry pipeline yielded results consistent with standard volumetric workflows. Overall, GOUHFI 2.0 provides a comprehensive solution for brain segmentation, parcellation and volumetry across field strengths, and constitutes the first deep-learning toolbox enabling robust cortical parcellation at UHF-MRI.2026-01-13T22:08:30ZMarc-Antoine FortinAnne Louise KristoffersenPaal Erik Goahttp://arxiv.org/abs/2509.16503v2Moiré Artifact Reduction in Grating Interferometry Using Multiple Harmonics and Total Variation Regularization2026-03-10T20:42:52ZX-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung imaging. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the attenuation, differential-phase, and dark-field images, respectively. Inaccuracies in grating position and multi-harmonic fringes produce Moiré artifacts when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. We have developed an image recovery algorithm that estimates the true phase stepping positions using multiple harmonics and total variation regularization, removing the Moiré artifacts present in the attenuation, differential-phase, and dark-field images. We demonstrate the algorithm's utility for the Talbot-Lau and Modulated Phase Grating Interferometers by imaging multiple samples, including PMMA microspheres and a euthanized mouse.2025-09-20T02:40:50ZHunter C. MeyerJoyoni DeyConner B. DooleyMurtuza S. TaqiVarun R. GalaChristopher D. MorrisonVictoria L. FontenotKyungmin HamLeslie G. ButlerAlexandra Noelhttp://arxiv.org/abs/2603.09898v1Initial Performance of a Long Axial FOV PET with TOF and DOI capabilities: IMAS system2026-03-10T16:52:15ZThis work summarizes the design, construction, initial performance evaluation and pilot clinical results of the IMAS system, a long axial field of view (FOV), also known as total-body (TB-), positron emission tomography (PET) prototype scanner. This PET enables for the first time in TB-PET imaging, simultaneously time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. The IMAS detector block is based on LYSO semi monolithic scintillators, with individual slab sizes of 3 mm x 25 mm x 20 mm each. Arrays of 1x8 slabs are coupled to 8x8 Silicon Photomultiplier arrays. A proprietary readout reduces the 64 signals to only 16 outputs, preserving both 3D photon impact positioning and timing accuracy. IMAS has a total of 30,720 channels. PETsys electronics is used for data acquisition. The IMAS geometry is based on 5 rings of 10 cm each, with a 5 cm gap between them. It defines an axial FOV of 71 cm with a bore aperture of 82 cm. We report in this work the pilot tests of the system performance and the first clinical results. We found that the system spatial resolution remained below 4 mm across the entire FOV, even at the off-radial position of 30 cm. A coincidence time resolution with a small size 22Na source of 560 ps FWHM was measured. A sensitivity of 56.54 cps/kBq is in good agreement with previous simulation studies; however, the noise equivalent count rates performance (79 kcps at 3.26 kBq/mL) was significantly lower than expected, likely due to a data transfer bottleneck between the system and the acquisition workstation. Finally, a comparison of one of the imaged patients with a commercial TOF PET/CT scanner is also provided, pinpointing an improved tumor identification for IMAS, and the advantages of TOF and especially DOI capabilities.2026-03-10T16:52:15ZAntonio J. GonzalezAlvaro Anreus-ValeroDavid SanchezSantiago Jiménez-SerranoMarta FreireAndrea Gonzalez-MontoroEdwing Y. Ulin-BrisenoNeus CucarellaJohn BarrioAndrew LaingJorge ÁlamoJulio BarberaLuis F. VidalMarc GilJose M. BenllochAlfonso RiosLuis Marti BonmatiIrene Torres-Espallardohttp://arxiv.org/abs/2410.21948v7Conceptualization of electronic dose to water for dosimetry in external beam radiotherapy2026-03-10T03:31:19ZThis study conceptualizes electronic dose to water, which is the radiation energy imparted to a unit mass of water by electronic interactions. The new dosimetry framework excludes nuclear interactions and consequently associated corrections and uncertainties from conventional dosimetry. Based on the international code of practice for dosimetry in radiotherapy, the procedures to determine electronic doses were formulated for high-energy photon, electron, proton, and ion beams. Nitrogen-based water-equivalent gas (WEG) mixtures were designed for use in gas-sealed ionization chambers for proton and ion beams. The proposed procedures were tested in a thought experiment and demonstrated compatibility with conventional absorbed dose for photon and electron beams and improved accuracy for proton and ion beams. The dosimetric uncertainty will be reduced from \SI{1.4}{\%} to \SI{1.3}{\%} for proton beams and from \SI{2.4}{\%} to \SI{1.9}{\%} for ion beams. With WEG ionization chambers, it will be further reduced to \SI{0.7}{\%} for proton beams and \SI{1.0}{\%} for ion beams. The new dose concept, electronic dose to water, can be readily used in radiotherapy practice and it will be medically more relevant than absorbed dose.2024-10-29T11:06:42Z8 pages, 6 tables, 2 figuresNobuyuki Kanematsuhttp://arxiv.org/abs/2603.08906v1Multi-Kernel Gated Decoder Adapters for Robust Multi-Task Thyroid Ultrasound under Cross-Center Shift2026-03-09T20:18:35ZThyroid ultrasound (US) automation couples two competing requirements: global, geometry-driven reasoning for nodule delineation and local, texture-driven reasoning for malignancy risk assessment. Under cross-center domain shift, these cues degrade asymmetrically, yet most multi-task pipelines rely on a single shared backbone, often inducing negative transfer. In this paper, we characterize this interference across CNN (ResNet34) and medical ViT (MedSAM) backbones, and observe a consistent trend: ViTs transfer geometric priors that benefit segmentation, whereas CNNs more reliably preserve texture cues for malignancy discrimination under strong shift and artifacts. Motivated by this failure mode, we propose a lightweight family of decoder-side adapters, the Multi-Kernel Gated Adapter (MKGA) and a residual variant (ResMKGA), which refine multi-scale skip features using complementary receptive fields and apply semantic, context-conditioned gating to suppress artifact-prone content before fusion. Across two US benchmarks, the proposed adapters improve cross-center robustness: they strengthen out-of-domain segmentation and, in the CNN setting, yield clear gains in clinical TI-RADS diagnostic accuracy compared to standard multi-task baselines. Code and models will be released.2026-03-09T20:18:35ZMaziar SabouriNourhan BayasiArman Rahmimhttp://arxiv.org/abs/2603.10058v1Controlled kHz laser-driven electron irradiations for pre-clinical applications2026-03-09T19:41:21ZWe report the first in-air irradiations of biological samples with kHz laser-driven electrons with beam energy 20 MeV, high-energy tail extending to 40 MeV, and average dose rate up to 30 Gy/min. An in-house procedure has been developed to characterize and deliver on-demand (i.e. pre-agreed date and time) the target electron beam energy, dose and dose uniformity. We present a tolerance analysis on the laser electron parameters, highlighting the importance of beam stability for precise irradiations of in vivo zebrafish embryos and in vitro U251 glioblastoma cell line. The observed improvement in the survival rate of the zebrafish embryos, combined with unchanged cytotoxicity in the cell cultures, indicates promising results for normal tissue sparing while maintaining anticancer efficacy. The pre-clinical results of this work represent an important milestone towards the clinical translation of laser-plasma accelerators.2026-03-09T19:41:21Z14 pages, 9 figuresC. M. LazzariniM. FavettaE. R. SzaboI. ZymakL. V. N. GoncalvesM. JechS. LorenzM. NevrklaJ. SismaA. SpadovaF. VithaR. AntipenkovP. BakuleA. GrenfellV. SobrW. SzubaJ. DudasA. EbertR. MolnarR. PolanekS. V. BulanovK. HideghetyG. M. Grittanihttp://arxiv.org/abs/2601.07370v2Magnetically Driven Elastic Microswimmers: Exploiting Hysteretic Collapse for Autonomous Propulsion and Independent Control2026-03-09T19:32:56ZWhen swimming at low Reynolds numbers, inertial effects are negligible and reciprocal movements cannot induce net motion. Instead, symmetry breaking is necessary to achieve net propulsion. Directed swimming can be supported by magnetic fields, which simultaneously provide a versatile means of remote actuation. Thus, we analyze the motion of a straight microswimmer composed of three magnetizable beads connected by two elastic links. The swimming mechanism is based on oriented external magnetic fields that oscillate in magnitude. Through induced reversible hysteretic collapse of the two segments of the swimmer, the two pairs of beads jump into contact and separate nonreciprocally. Due to higher-order hydrodynamic interactions, net displacement results after each cycle. Different microswimmers can be tuned to different driving amplitudes and frequencies, allowing for simultaneous independent control by just one external magnetic field. The swimmer geometry and magnetic field shape are optimized for maximum swimming speed using an evolutionary optimization strategy. Thanks to the simple working principle, an experimental realization of such a microrobot seems feasible and may open new approaches for microinvasive medical interventions such as targeted drug delivery.2026-01-12T09:51:57Z12 pages, 7 figures, submitted to ACS Nanoscience AuTheo LequyAndreas M. Menzel10.1021/acsnanoscienceau.6c00014http://arxiv.org/abs/2603.08829v1Feasibility of Concurrent 1H MRS & 31P MRSI at 7T: Brain Energy Metabolism Responses to Hyperglycemia2026-03-09T18:40:01ZHow the human brain adjusts fuel handling and its bioenergetic state during changing glucose levels remains difficult to assess noninvasively. In this study, we established an interleaved multinuclear 7 T MR spectroscopy protocol to track a glucose-related 1H signal alongside 31P measures of high-energy phosphate metabolism during a hyperglycemic clamp. Five healthy adults completed a morning, fasted infusion experiment consisting of baseline, ramp-up, and hyperglycemic stages over approx. 120 min. Short-block, short-TE 1H single-voxel spectroscopy (STEAM, TE = 11 ms; mean block duration 5.71 (SD:0.62 min)) was acquired in frontal cortex and quantified using the composite Glucose+Taurine (Glc+Tau) measure. 31P was acquired with rapid 3D PETALUTE MRSI using an ultrashort echo time (UTE; TE = 65 micros; 381 s per block), and high-energy phosphate ratios were derived from a posterior cortical region of interest. Across participants, 1H Glc+Tau increased with blood glucose and showed significant elevations from baseline into hyperglycemia. In parallel, 31P ratios exhibited smaller but significant glycemia-linked responses: both PCr/Pi and gamma-ATP/Pi increased with blood glucose and differed across glucose clamp stages. These findings show that 1H and 31P MRS(I) can be interleaved at 7 T to measure energy metabolism within a single session2026-03-09T18:40:01ZMark WidmaierBrooke C. MatsonUzay EmirJanice J. Hwanghttp://arxiv.org/abs/2602.23463v2Synthetic Data in MR Spectroscopy: Current Practices, Applications, and Considerations2026-03-09T12:33:29ZThe use of synthetic data has emerged as an essential tool in Magnetic Resonance Spectroscopy (MRS) research and applications, providing advantages for optimization of acquisition, software validation, deep learning applications, and enhanced reproducibility. Importantly, synthetic data addresses challenges of limited training data availability, particularly for clinical populations, and offers controlled solutions for investigating uncertainties and unexplained variance with in vivo data. This work provides a review and evaluation of current practices in the use and generation of synthetic data within the MRS field. Conducted by the MRS Synthetic Data Working Group under the Code & Data Sharing Committee of the MRS Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM), this manuscript encompasses existing literature, supplemented by collective experience and in-house methodologies.2026-02-26T19:42:14ZWord Count: 20,493; Figure Count: 6; Table Count: 0 (All tables are in the supplement)John T. LaMasterAaron T. GudmundsonAlireza AbaeiSeyma AlcicekArturo AlvaradoOvidiu AndronesiTiffany K. BellWolfgang BognerHanna BuglerAlexander R CravenCristina CudalbuAlma DavidsonChristopher W. Davies-JenkinsDinesh DeelchandRichard A. E. EddenMorteza EsmaeiliCandace C FleischerAbdelrahman GadGuglielmo GenoveseSaumya GurbaniAshley D. HarrisPierre-Gilles HenryKay Chioma IgweAjin JoyMargarida Julià-SapéHyeonjin KimRoland KreisFan LamKarl LandheerBernard LanzChu-Yu LeeClémence LigneulJulian P. MerkoferJack J. MillerJessie MossoStanislav MotykaEloïse MougelPaul G. MullinsSaipavitra Murali-ManoharChloé NajacShinichiro NakajimaGeorg OeltzschnerEsin Ozturk-IsikMarco PalomboUlrich PilatusJustyna PlatekEmma Van PraaghXiaobo QuRudy RizzoChristopher T. RodgersEsau Poblador RodriguezYeison RodriguezManoj K SammiDennis M. J. van de SandeManoj Kumar SarmaFrancesca SaviolaAnouk SchranteeAmirmohammad ShamaeiDunja SimicicBrian J SoherNico SollmannYulu SongJeffrey A StanleyBernhard StrasserAntonia SusnjarKelley M. SwanbergM. Albert ThomasIvan TkáčZhangren TuPaul J. WeiserMark WidmaierMartin WilsonChristopher J. WuLijing XinHelge J. Zöllnerİpek ÖzdemirMRS Synthetic Data Working GroupAntonia Kaiser