https://arxiv.org/api/LbYkga0LorRBqjkVYxwxTchbfLs 2026-04-10T00:11:52Z 8808 315 15 http://arxiv.org/abs/2601.03172v1 Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs 2026-01-06T16:52:08Z Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI. 2026-01-06T16:52:08Z Szymon Parzych Szymon Niedźwiecki Ermias Yitayew Beyene Neha Chug Maurizio Conti Catalina Curceanu Eryk Czerwiński Manish Das Kavya Valsan Eliyan Jakub Hajduga Sharareh Jalali Krzysztof Kacprzak Tevfik Kaplanoglu Łukasz Kapłon Kamila Kasperska Aleksander Khreptak Grzegorz Korcyl Tomasz Kozik Deepak Kumar Anoop Kunimmal Venadan Karol Kubat Edward Lisowski Filip Lisowski Justyna Mędrala-Sowa Wiktor Mryka Simbarashe Moyo Piyush Pandey Elena Perez del Rio Alessio Porcelli Bartłomiej Rachwał Martin Rädler Axel Rominger Sushil Sharma Kuangyu Shi Magdalena Skurzok William M. Steinberger Tomasz Szumlak Pooja Tanty Keyvan Tayefi Ardebili Satyam Tiwari Ewa Łucja Stępień Paweł Moskal http://arxiv.org/abs/2504.19155v3 Machine Learning-Based Modeling of the Anode Heel Effect in X-ray Beam Monte Carlo Simulations 2026-01-06T13:52:31Z To develop a machine learning-based framework for accurately modeling the anode heel effect in Monte Carlo simulations of X-ray imaging systems, enabling realistic beam intensity profiles with minimal experimental calibration. Multiple regression models were trained to predict spatial intensity variations along the anode-cathode axis using experimentally acquired weights derived from beam measurements across different tube potentials. These weights captured the asymmetry introduced by the anode heel effect. A systematic fine-tuning protocol was established to minimize the number of required measurements while preserving model accuracy. The models were implemented in the OpenGATE 10 and GGEMS Monte Carlo toolkits to evaluate their integration feasibility and predictive performance. Among the tested models, gradient boosting regression (GBR) delivered the highest accuracy, with prediction errors remaining below 5% across all energy levels. The optimized fine-tuning strategy required only six detector positions per energy level, reducing measurement effort by 65%. The maximum error introduced through this fine-tuning process remained below 2%. Dose actor comparisons within Monte Carlo simulations demonstrated that the GBR-based model closely replicated clinical beam profiles and significantly outperformed conventional symmetric beam models. This study presents a robust and generalizable method for incorporating the anode heel effect into Monte Carlo simulations using machine learning. By enabling accurate, energy-dependent beam modeling with limited calibration data, the approach enhances simulation realism for applications in clinical dosimetry, image quality assessment, and radiation protection. 2025-04-27T08:19:47Z 15 pages, 8 figures Phys. Med. Biol. 71, 015007 (2026) Hussein Harb Didier Benoit Axel Rannou Chi-Hieu Pham Valentin Tissot Bahaa Nasr Julien Bert 10.1088/1361-6560/ae2cdf http://arxiv.org/abs/2601.03313v1 Fine and Hyperfine Interactions with Multi-level Spin Relaxation of the purified Giese-Salt in Veterinary Medicine: Prussian Blue Compound Ammonium-Ferric-Hexacyano-Ferrate 2026-01-06T12:39:30Z Ammonium ferric hexacyanoferrate is a veterinary-medical milestone and antidote against radiocesium, well-known as Giese-salt after the Chernobyl disaster fed to domestic and wild animals, which shows even a rich interplay of properties in nanostructural chemistry and ferromagnetism. Among the broad analytical techniques, the ambivalence of macroscopic micrometer-sized agglomerates and nanoparticle sizes, a suggested enlarged Fe(II)$-$C$\equiv$N$-$Fe(III) bond length by Fe K-edge XAFS results and multi-level spin relaxation in $^{57}$Fe Mössbauer spectroscopy are highlighted. This sets this underestimated compound in a new light, e.g., for modern biomedicine and biofunctionality, extending its essential importance in addition to hypothetical future nuclear incidents 2026-01-06T12:39:30Z 47 pages Sascha Albert Bräuninger Damian Alexander Motz Sebastian Praetz Felix Seewald Katharina Strecker Carla Vogt Hans-Henning Klauss Birgit Kanngießer Hermann Seifert http://arxiv.org/abs/2601.02538v1 A Green Solution for Breast Region Segmentation Using Deep Active Learning 2026-01-05T20:25:34Z Purpose: Annotation of medical breast images is an essential step toward better diagnostic but a time consuming task. This research aims to focus on different selecting sample strategies within deep active learning on Breast Region Segmentation (BRS) to lessen computational cost of training and effective use of resources. Methods: The Stavanger breast MRI dataset containing 59 patients was used in this study, with FCN-ResNet50 adopted as a sustainable deep learning (DL) model. A novel sample selection approach based on Breast Anatomy Geometry (BAG) analysis was introduced to group data with similar informative features for DL. Patient positioning and Breast Size were considered the key selection criteria in this process. Four selection strategies including Random Selection, Nearest Point, Breast Size, and a hybrid of all three strategies were evaluated using an active learning framework. Four training data proportions of 10%, 20%, 30%, and 40% were used for model training, with the remaining data reserved for testing. Model performance was assessed using Dice score, Intersection over Union, precision, and recall, along with 5-fold cross-validation to enhance generalizability. Results: Increasing the training data proportion from 10% to 40% improved segmentation performance for nearly all strategies, except for Random Selection. The Nearest Point strategy consistently achieved the lowest carbon footprint at 30% and 40% data proportions. Overall, combining the Nearest Point strategy with 30% of the training data provided the best balance between segmentation performance, efficiency, and environmental sustainability. Keywords: Deep Active Learning, Breast Region Segmentation, Human-center analysis 2026-01-05T20:25:34Z Sam Narimani Solveig Roth Hoff Kathinka Dæhli Kurz Kjell-Inge Gjesdal Jürgen Geisler Endre Grøvik http://arxiv.org/abs/2508.10527v2 A 240 Elements Matrix Probe with Aberration Mask for 4D Carotid Artery Computational Ultrasound Imaging 2026-01-05T15:15:31Z Three-dimensional (3D) ultrasound provides enhanced visualization of the carotid artery (CA) anatomy and volumetric flow, offering improved accuracy for cardiovascular diagnosis and monitoring. However, fully populated matrix transducers with large apertures are complex and costly to implement. Computational ultrasound imaging (cUSi) offers a promising alternative by enabling simplified hardware design through model-based reconstruction and spatial field encoding. In this work, we present a 3D cUSi system tailored for CA imaging, consisting of a 240-element matrix probe with a 40 x 24 mm$^2$ large aperture and a spatial encoding mask. We describe the system's design, characterization, and image reconstruction. Phantom experiments show that computational reconstruction using matched filtering (MF) significantly improves volumetric image quality over delay-and-sum (DAS), with spatial encoding enhancing lateral resolution at the cost of reduced contrast ratio. LSQR-based reconstruction was demonstrated to further improve resolution and suppress artifacts. Using both Hadamard and 16-angle plane wave transmission schemes, the system achieved high-resolution images with reasonable contrast, supporting the feasibility of 4D CA imaging applications. 2025-08-14T11:02:21Z Maintext: 11 pages, 7 figures Supporting: 2 pages Yuyang Hu Michael Brown Didem Dogan Mahé Bulot Maxime Cheppe Guillaume Ferin Geert Leus Antonius F. W. van der Steen Pieter Kruizinga Johannes G. Bosch http://arxiv.org/abs/2601.02146v1 Investigating the impact of copper-PEDOT:PSS matrix towards non-enzymatic electrochemical creatinine detection 2026-01-05T14:19:19Z Electrochemical creatinine sensors offer great promise towards rapid, reagent-free and point-of-care (POC) kidney-function monitoring. However, challenges related to analyte binding, data reproducibility, sensitivity, fouling and device degradation deter its widespread implementation. Here, we show how a carbon electrode modified with a combination of poly(3,4-ethylene dioxythiophene): poly(styrene sulfonate) (PEDOT:PSS) and copper nanoparticles (CuNPs) can rapidly and accurately detect creatinine (CT) in artificial urine media employing electrochemical techniques. Applying redox potential sweeps (vs Ag/AgCl) using copper sulfate (CuSO4) solution on such sensor facilitates the CuNP embedding process inside the conjugated polymer matrix which has been further validated by supporting techniques. We predicted and validated the formation and contribution of two Cu-CT coordination complexes corresponding to Cu(I) and Cu(II) states, which are responsible for CT detection. The fabricated CT sensor exhibits high selectivity against major artificial urine interferents and is stable for a month showing minimal degradation (0.53%) in peak current value. Such sensors can be utilized to detect and monitor different stages of renal failure in real-time patient samples. 2026-01-05T14:19:19Z 18 pages, 5 figures, 1 table Chirantan Das Subhrajit Sikdar Shreyas K. Vasantham Piotr Pięta Marcin Strawski Marcin S. Filipiak Paweł Borowicz Yurii Promovych Piotr Garstecki http://arxiv.org/abs/2512.18793v2 Quantitative ultrasound imaging of bone: anatomical images, tissue structural quality, and pulsatile blood flow 2026-01-05T14:02:55Z We propose an ultrasound approach which provides, with one single examination and one single device, access to three bone biomarkers: anatomy, tissue quality and blood flow. It unlocks ultrasound imaging inside bone by accounting for ultrasound wave speed heterogeneity and anisotropic wave refraction. This study reports the first \emph{in vivo} evaluation with a comparison to peripheral Quantitative Computed Tomography (pQCT) and modulations of blood flow. Anatomical multi-layer bone-corrected reconstruction was validated at the tibia of healthy volunteers against pQCT and showed agreement on bone cortex interfaces. Estimation of axial and radial ultrasound wave speeds in cortical bone tissue (i.e. along the tissue symmetry axis and normal to it) demonstrated good reproducibility and positive correlation with bone mineral density measured by pQCT. Pulsatile blood flow was mapped and quantified in cortical and medullary regions. A directional ray selection method was developed to enhance blood signal extraction by reducing strong specular reflections originating from the outer and inner surfaces of the bone cortex. Physiological and non-physiological modulations of blood flow, namely head-up/head-down tilt table maneuvers and arterial occlusions, demonstrated the method sensitivity to blood flow variations. For the first time, reactive hyperemia was observed inside bone cortex. These results demonstrate the feasibility of a portable, non-ionizing, and quantitative ultrasound approach for structural, anatomical, and vascular characterization of bone tissue. This approach may offer new diagnostic capabilities for bone disorders, for instance osteoporosis, delayed fracture healing or osteonecrosis. 2025-12-21T16:10:59Z Gabrielle Laloy-Borgna Nastassia Navasiolava Pim Hutting Andréa Bertona Amadou S. Dia Sébastien Salles Anthony Augé Alice Mazzolini Quentin Grimal Olivier Lucidarme Hervé Locrelle Jacques-Olivier Fortrat Laurence Vico Marc-Antoine Custaud Guillaume Renaud http://arxiv.org/abs/2510.02847v4 Dipolar order mapping based on spin-lock magnetic resonance imaging 2026-01-05T03:39:22Z Purpose: Inhomogeneous magnetization transfer (ihMT) effect reflects dipolar order with a dipolar relaxation time ($T_{1D}$), specific to motion-restricted macromolecules. We aim to quantify $T_{1D}$ using spin-lock MRI technique. Methods: In the proposed method, we introduce a $T_{1D}$-specific ratio, denoted as $RATIO_{dosl}$. This ratio is derived from the distinct relaxation rate $R_{dosl}$, calculated as the difference between dual-frequency relaxation $R_{1ρ}^{dual}$ and single-frequency $R_{1ρ}^{single}$ relaxation measurements. A novel rotary-echo spin-lock sequence was developed to enable dual-frequency spin-lock acquisition. We established a framework to estimate $T_{1D}$, as well as the macromolecular pool fraction (MPF) map. The proposed approach was validated via numerical simulations, phantom studies, and demonstrated in vivo in human white matter. Results: Simulations revealed the high sensitivity of $RATIO_{dosl}$ to $T_{1D}$, and substantiated the accuracy and robustness of the proposed methods. Phantom experiments demonstrated robust ihMT contrast and confirmed the capability of $T_{1D}$ quantification via $RATIO_{dosl}$. In vivo studies supported the clinical viability of this approcah, achieving simultaneous $T_{1D}$ and MPF mapping using only three spin-lock prepared images. Across ten healthy volunteers, the mean white matter $T_{1D}$ ranged from approximately 3.70 to 4.80 ms. Conclustion: We propose a novel method for $T_{1D}$ quantification based on spin-lock MRI. By requiring only three contrast-prepared images, this technique provides a promising pathway for robust, rapid, and simultaneous $T_{1D}$ and MPF quantification with fewer confounds 2025-10-03T09:34:06Z Zijian Gao Qianxue Shan Ziqin Zhou Ziqiang Yu Weitian Chen http://arxiv.org/abs/2601.01667v1 An Ingestible Light Source for Deep Photoacoustic Imaging 2026-01-04T21:00:05Z Photoacoustic tomography leverages ultrasound's deep tissue penetration to retrieve optical absorption contrast well beyond the optical diffusion limit. Conventional photoacoustic systems rely on externally delivered light and are therefore constrained by optical attenuation, limiting imaging depths to several centimeters. Here, we overcome this constraint using a compact, acoustically powered device that provides optical excitation directly from within the target medium. By exploiting the weak attenuation of low-MHz ultrasound, acoustic energy is transmitted through tissue to wirelessly power a pulsed laser diode. The emitted light pulses generate photoacoustic signals that encode local optical absorption at clinically relevant depths, which could enable imaging in regions such as the gastrointestinal tract that are inaccessible to surface-based illumination. We demonstrate this approach by imaging through a 12 cm thick phantom, establishing a pathway toward deep-tissue photoacoustic imaging. 2026-01-04T21:00:05Z David C. Garrett Lihong V. Wang http://arxiv.org/abs/2510.17283v3 Optimized Single-Core PCF-Based SPR Biosensor for High-Performance Early-Stage Multi-Cancer Detection 2026-01-04T19:31:37Z In this study, we present a highly sensitive Surface Plasmon Resonance (SPR)-based biosensor integrated with a circular-lattice Photonic Crystal Fiber (PCF) for early-stage cancer detection. The proposed sensor leverages the synergy between SPR and PCF technologies to overcome the bulkiness and limited sensitivity of traditional SPR systems. A thin gold (Au) layer, responsible for plasmon excitation, is deposited on the fiber structure, while a nanolayer of vanadium pentoxide (V2O5) is introduced to enhance adhesion between the gold and the silica background, improving structural stability and field confinement. The sensor is designed to detect refractive index (RI) variations in biological analytes, specifically targeting cancerous cells from skin, blood, and adrenal gland tissues. The optical characteristics and performance of the sensor were thoroughly analyzed using the Finite Element Method (FEM) in COMSOL Multiphysics 6.1, allowing for precise simulation and optimization. The sensor demonstrates high sensitivity within the RI range of 1.360-1.395, corresponding to the RI values of the target cancer cells. Remarkable wavelength sensitivities of 21,250 nm/RIU, 53,571 nm/RIU, and 103,571 nm/RIU were achieved for skin, blood, and adrenal gland cancers, respectively. In addition, a maximum figure of merit (FOM) of 306.424 RIU^-1 and a spectral resolution (SR) of 9.57x10^-7 RIU further affirm the sensor's exceptional detection capabilities. These findings indicate the proposed SPR-PCF sensor's strong potential for real-time, label-free biosensing applications, particularly in precise and early cancer diagnostics. 2025-10-20T08:16:43Z Tonmoy Malakar Miss Nourin Nurain Amina Zarin Tasnim Nijhum Nazmus Shakib Lalin http://arxiv.org/abs/2310.16055v3 A nonconservative kinetic model under the action of an external force field for modeling the medical treatment of autoimmune response 2026-01-03T11:56:04Z In this paper, we develop a nonconservative kinetic framework to be applied to the study of immune system dysregulation. From the modeling viewpoint, the model regards a system composed of stochastically interacting agents, under the action of an eternal force field. According to the application perspectives of this paper, the external force field has a specific analytical shape. In this case, some analytical results are proved, i.e. existence, uniqueness, positivity, and boundedness of solution of the related Cauchy problem, at least locally in time. Then, the model is refined to be implemented for the study of treatment strategies in case of autoimmune response. Specifically, we distinguish the autonomous case from the nonautonomous one, representing the absence or delivery of drugs, respectively. The former allows us to gain some stability results. Whereas, the latter is qualitatively studied. Numerical simulations are provided for both schemes. 2023-10-13T08:58:27Z Communications in Nonlinear Science and Numerical Simulation 137 (2024): 108126 Marco Menale Romina Travaglini 10.1016/j.cnsns.2024.108126 http://arxiv.org/abs/2601.00997v1 AI-Assisted Hyperspectral Interferometry and Single-Cell Dispersion Imaging 2026-01-02T22:39:55Z Interferometry techniques are essential for extracting phase information from optical systems, enabling precise measurements of dispersion and highly sensitive detection of perturbations. While phase sensing offers enhanced sensitivity compared to conventional spectroscopy methods, this sensitivity often makes systems more vulnerable to external factors such as vibrations, introducing instability and noise. In this work, we demonstrate a broadband and AI-enhanced interferometry method, denoted general polarization common-path interferometry (GPCPI), that relaxes the polarization constraints of traditional common-path interferometry. The polarization decoupling feature enables simultaneous amplitude and phase measurements supplemented with deep neural autoencoders to detect phase anomalies in the spectrum through the analysis of second order derivative mapping of the phase profile, enhancing the accuracy of broadband phase measurements. The approach enables an order of magnitude improvement in phase stability compared to state-of-the-art interferometry techniques, leading to higher accuracy in phase sensing. Plasmonic metasurface phase sensing and hyperspectral single-cell dispersion imaging demonstrate the capability and sensitivity of the method over conventional spectroscopy. Our own adopted version of deep learning model, ConvNeXt V2, enables single-shot and real-time tracking of phase variation with minimized noise. Interference fringes over the cell cultured samples reveal the fingerprints of the normal (CCD-32Sk) vs cancerous (COLO-829) skin cells, enabling robust cell classification and disease diagnosis at single-cell level. The proposed interferometry technique offers a reliable, compact, and stable solution for broadband phase measurements and single-cell dispersion imaging for applications in metrology, molecular diagnostics, drug discovery, and quantum sensing. 2026-01-02T22:39:55Z Kamyar Behrouzi Tanveer Ahmed Siddique Megan Teng Walid Redjem Liwei Lin Boubacar Kante http://arxiv.org/abs/2507.09765v2 CRYSP: a Total-Body PET based on cryogenic cesium iodide crystals 2026-01-02T22:03:26Z Total Body PET (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. We investigate the performance of pure CsI crystals operated at cryogenic temperatures ($\sim$100 K), where they achieve a light yield of approximately $10^5$ photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings. 2025-07-13T19:48:31Z 20 pages, 12 figures Phys. Med. Biol. 71 025001 (2026) S. R. Soleti P. Dietz R. Esteve J. Garcìa-Barrena V. Herrero F. Lopez F. Monrabal L. Navarro-Cozcolluela E. Oblak J. Pelegrìn J. Renner J. Toledo S. Torelli J. J. Gòmez-Cadenas 10.1088/1361-6560/ae35c8 http://arxiv.org/abs/2512.22026v2 Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan 2026-01-02T17:39:26Z In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner. We validate the accuracy of stopping power ratio (SPR) calculations using a conventional stoichiometric calibration approach and a prototype software, TissueXplorer. A validated CT simulator (DukeSim) was used to generate photon-counting CT projections of a computational head model, which were reconstructed with an open-source toolbox (ASTRA). The dose of 2 Gy was delivered through protons in a single fraction to target two different cases of nasal and brain tumors with a single lateral beam angle. Ground truth treatment plan was made directly on the computational head model using clinical treatment planning software (RayStation). This plan was then recalculated on the corresponding CT images for which SPR values were estimated using both the conventional method and the prototype software TissueXplorer. The mean percentage difference in estimating the stopping power ratio with TissueXplorer in all head tissues inside the scanned volume was 0.28%. Stopping power ratios obtained with this method showed smaller dose distribution differences from the ground truth plan than the conventional stoichiometric calibration method on the computational head model. Virtual imaging offers an alternative approach to validation of the SPR prediction from CT imaging, as well as its effect on the dose distribution and thus downstream clinical outcomes. According to this simulation study, software solutions that utilize spectral information, such as TissueXplorer, hold promise for more accurate prediction of the stopping power ratio than the conventional stoichiometric approach. 2025-12-26T13:14:47Z 16 pages, 5 figures; v2 Corrected spelling of an author name S. Vrbaški G. Stanić S. Molinelli M. Bhattarai E. Abadi M. Ciocca E. Samei http://arxiv.org/abs/2601.06099v1 Co-doping of silicate bioceramics as a potential strategy to further enhance mono-doping consequences 2026-01-02T15:19:03Z Silicate bioceramics have attracted significant attention in medical applications, particularly in hard tissue regeneration, because of their controllable chemical, physical, and biological functionalities, while ensuring biocompatibility. The coordination of silicate bioceramics with mono-dopants has been extensively studied to enhance their osteogenesis, angiogenesis, and antibacterial activity. However, the concept of employing dual or multiple co-doping to further enhance these biomaterials still demands more attention. This review paper originally focuses on the effect of chemical interactions among co-dopants and the principal constituents of the silicates, on the bio-behavior of these bioceramics. Additionally, future prospects of co-doped silicate bioceramics are outlined, including in vivo studies, clinical trials, and potential commercialization. 2026-01-02T15:19:03Z Coordination Chemistry Reviews, 514 (2024) 215963 Sohrab Mofakhami Erfan Salahinejad 10.1016/j.ccr.2024.215963