https://arxiv.org/api/tL3Nqz8mnz4VmvtIt1cmznT/gNw 2026-06-22T01:26:45Z 8985 300 15 http://arxiv.org/abs/2512.24261v2 First Positronium Lifetime Imaging using $^{52}$Mn and $^{55}$Co with a plastic-based PET scanner 2026-03-23T20:09:06Z Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. In this work, we report the first PLI measurements performed with $^{52}$Mn and $^{55}$Co using the modular J-PET. Four samples were studied in each experiment: two Certified Reference Materials (polycarbonate and fused silica) and two human tissues (cardiac myxoma and adipose). The selection of PLI events was based on the registration of two 511~keV annihilation photons and one prompt gamma in triple coincidence. From the resulting lifetime spectra we extracted the mean ortho-positronium lifetime $τ_{\text{oPs}}$ and the mean positron lifetime $ΔT_{\text{mean}}$ for each sample. The measured values of $τ_{\text{oPs}}$ in polycarbonate using both isotopes matches well with the certified reference values. Furthermore, $^{55}$Co reproduced identical results for fused-silica measurements at their respective uncertainty levels. In contrast, measurements with $^{52}$Mn in fused silica show a minor deviation, which could be caused by the Parafilm spacer. In myxoma and adipose tissue, the reduced $τ_{\text{oPs}}$ values are mainly linked to the long storage history of the samples rather than to the choice of isotope. Comparing peak-to-background ratios and spectral purity, $^{55}$Co provides cleaner PLI data under the same experimental conditions. Although $^{52}$Mn offers a longer half-life and a multi gamma cascade enhancing $β^{+}$ + $γ$ coincidences, but at the expense of higher background. In this study, we demonstrate that the applied selection criteria on the data measured with the modular J-PET can be used for PLI studies even with radionuclides with complex decay patterns. 2025-12-30T14:36:52Z Scientific Reports (2026) Manish Das Sushil Sharma Ermias Yitayew Beyene Aleksander Bilewicz Jarosław Choiński Neha Chug Catalina Curceanu Eryk Czerwiński Jakub Hajduga Sharareh Jalali Krzysztof Kacprzak Tevfik Kaplanoglu Łukasz Kapłon Kamila Kasperska Aleksander Khreptak Grzegorz Korcyl Tomasz Kozik Karol Kubat Deepak Kumar Sumit Kumar Kundu Anoop Kunimmal Venadan Edward Lisowski Filip Lisowski Justyna Medrala-Sowa Simbarashe Moyo Wiktor Mryka Szymon Niedźwiecki Anand Pandey Piyush Pandey Szymon Parzych Alessio Porcelli Bartłomiej Rachwał Martin Rädler Narendra Rathod Noman Razzaq Axel Rominger Kuangyu Shi Magdalena Skurzok Maciej Słotwiński Anna Stolarz Tomasz Szumlak Pooja Tanty Keyvan Tayefi Ardebili Satyam Tiwari Kavya Valsan Eliyan Rafał Walczak Ewa Ł. Stępień Paweł Moskal 10.1038/s41598-026-43965-z http://arxiv.org/abs/2603.22092v1 T$_2$* and Susceptibility Mapping as Indicators of Placental Health 2026-03-23T15:22:35Z Objective(s): T$_2$* and susceptibility ($χ$) MRI mapping provide complimentary measures of the haemodynamic environment in the placenta. The aims of this work were to use these simultaneously obtained measures to investigate the role of oxygen distribution on the well-established reduction of T$_2$* with gestational age found in healthy pregnancies and explore differences in both measures in compromised placentas. Methods: T$_2$* and $χ$ were measured simultaneously from a double echo, echo planar scan of the whole placenta, across a range of gestational ages and pregnancy complications. Regional variations across the placenta were investigated. Results: Whole placental mean T$_2$* was more correlated with standard deviation of $χ$ than mean $χ$ indicating it is more driven by increasing local inhomogeneities rather than bulk deoxygenation with healthy gestation. Compromised placentas also showed increased standard deviation of $χ$ as well as lower mean T$_2$* suggesting flow/uptake mismatch and reduced oxygenation. Regionally, the susceptibility was lowest (most oxygenated) and least variable in the central region of the placenta indicating good mixing and refreshment of blood in this area. The susceptibility was highest (most deoxygenated) and most variable at the fetal side, suggesting less effective perfusion in this region. Compromised cases showed the greatest difference on the fetal side for both mean and standard deviation of $χ$. T$_2$* was lowest at the fetal side for healthy and compromised cases but the maternal and central regions better distinguished between the two groups. Conclusion(s): T$_2$* and susceptibility can be mapped simultaneously from a single MRI scan and provide complimentary information about the function of the placenta across healthy gestational development, and as a potential indicator of placental compromise. 2026-03-23T15:22:35Z Amy Turnbull George Hutchinson Louise Dewick Ruizhe Li Chris Bradley Lopa Leach Dimitrios Amantis Xin Chen Grazziela Figueredo Kate F Walker Penny Gowland http://arxiv.org/abs/2603.21980v1 Fast undersampled dynamic MRI reconstruction using explicit representation learning with Gaussian splatting 2026-03-23T13:43:55Z Motivation: Quickly obtaining high-quality MRI from accelerated acquisitions is important to mitigate motion artifacts, maintain patient comfort, and improve clinical efficiency. Goals: To obtain high-quality dynamic MRI using efficient, personalized models. Approach: We propose a novel explicit representation learning approach using Gaussian splatting. Multiple Gaussian primitives are trained to represent the underlying tissue. We extend the Gaussian splatting framework to model anatomical motion, enabling learning an efficient, explicit representation of dynamic MRI. Results: Gaussian splats can be trained in 60s with 0.5ms/dynamic inference time. High-quality cardiac MRI is obtained at R=16. We show that the properties of the Gaussians directly encode physiological properties. 2026-03-23T13:43:55Z Accepted at ISMRM 2026 M. L. Terpstra C. A. T. van den Berg http://arxiv.org/abs/2603.21732v1 Hyperspectral imaging solutions for brain tissue metabolic and haemodynamic monitoring: an updated perspective 2026-03-23T09:21:11Z Since the publication of our review article Hyperspectral imaging solutions for brain tissue metabolic and hemodynamic monitoring: past, current and future developments in 2018, the technological and applicational landscape of the use of hyperspectral imaging (HSI) in brain sciences has evolved and transformed significantly. The number of studies and works where HSI has been deployed in its many forms to map and monitor the haemodynamic and metabolic states of cerebral tissues have grown exponentially, to such a point where an update on the cur-rent state of the art is timely, and we believe would be desirable for both long-term experts in the field, as well as for any new researcher approaching it for the first time. In this commentary, we provide a renewed perspective on the newest and latest developments in brain haemodynamic and metabolic monitoring with HSI over the past eight years. Our hope is that even greater breakthroughs and broader, more numerous novel applications will come forward in the future for the technology, that may benefit from this new overview, as they did from the original one. 2026-03-23T09:21:11Z Luca Giannoni Frédéric Lange Ilias Tachtsidis 10.1088/2040-8986/ae7582 http://arxiv.org/abs/2603.21706v1 Comprehensive Dosimetric Verification and Positional Sensitivity Analysis in Brachytherapy: A Unified ESAPI Tool for HDR and LDR Treatments 2026-03-23T08:46:31Z This study presents the development and validation of an independent software tool based on the Varian Eclipse Scripting API (ESAPI) for multi-modal brachytherapy Quality Assurance (QA). The tool addresses GEC-ESTRO HDR protocols and LDR positional uncertainty analysis. Engineered in C#, the application interfaces with BrachyVision, Vitesse, and Variseed, enabling independent TG-43 dose calculations -- comparing point and line source models -- integrated with EQD2-based radiobiological summation. In HDR cervical cancer, the tool successfully automated EMBRACE II protocol reporting, streamlining clinical workflows by combining dosimetric QA with predictive and prospective planning. For LDR prostate treatments, a stochastic simulation module quantified the impact of systematic (rigid-body) versus random seed displacements on target coverage ($D_{90\%}$) and Organs at Risk (OAR) safety ($D_{0.1cc}$). Sensitivity analysis in LDR prostate implants was benchmarked using two clinical cases (prostate volumes 31 cc and 71.3 cc). LDR simulations revealed that systematic displacements ($\pm$ 2 mm) yielded significantly higher dosimetric deviations than stochastic movements. In the 31 cc case, systematic shifts resulted in a rectal ($D_{0.1cc}$) standard deviation (SD) of 24.3 Gy, whereas random displacements reduced this to 12.4 Gy. In the 71.3 cc case, random displacements resulted in a rectal $D_{0.1cc}$ SD of 7.6 Gy, confirming that smaller volumes exhibit heightened sensitivity to errors. Technical analysis demonstrated that the point source model overestimated bladder $D_{10\%}$ by 8% relative to the line source model. Our findings confirm that systematic rigid-body shifts represent a greater clinical risk for OAR toxicity than stochastic migration. Integrating predictive sensitivity analysis into the clinical workflow significantly enhances patient safety through robust plan verification. 2026-03-23T08:46:31Z 13 pages, 2 tables, 5 figures J. A. Valgoma http://arxiv.org/abs/2511.03115v3 SDE-based Monte Carlo dose calculation for proton therapy validated against Geant4 2026-03-22T12:22:01Z Objective: To assess the accuracy and computational performance of a stochastic differential equation (SDE)--based model for proton beam dose calculation by benchmarking against Geant4 in simplified phantom geometries. Approach: Building on Crossley et al. (2025), we implemented the SDE model using standard approximations to interaction cross sections and mean excitation energies, enabling straightforward adaptation to new materials and configurations. The model was benchmarked against Geant4 in homogeneous, longitudinally heterogeneous and laterally heterogeneous phantoms to assess depth--dose behaviour, lateral transport and material heterogeneities. Main results: Across all phantoms and beam energies, the SDE model reproduced the main depth--dose characteristics predicted by Geant4, with proton range agreement within 0.2 mm for 100 MeV beams and 0.6 mm for 150 MeV beams. Voxel--wise comparisons yielded gamma pass rates exceeding 95% under 2%/0.5 mm criteria with a 1% dose threshold. Differences were localised to steep dose gradients or material interfaces, while overall lateral beam dispersion was well reproduced. The SDE model achieved speed-up factors of about 2.5--3 relative to single-threaded Geant4. Significance: The SDE approach reproduces key dosimetric features with good accuracy at lower computational cost and is amenable to parallel and GPU implementations, supporting fast proton therapy dose calculations. 2025-11-05T01:45:57Z 30 pages, 11 figures Christopher B. C. Dean Maria L. Pérez-Lara Emma Horton Matthew Southerby Jere Koskela Andreas E. Kyprianou http://arxiv.org/abs/2502.10845v2 Hard X-ray/Soft gamma-ray Laue Lenses for High Energy Astrophysics 2026-03-20T12:33:17Z The study of the celestial phenomena in the hard X-ray/soft gamma-ray band(20 keV--1 MeV) is very intriguing but also very difficult to be performed with the needed sensitivity. In this review I will discuss the astrophysical importance of the soft gamma-ray astronomy, its difficulties to solve its issues with the current instrumentation, and a possible solution achievable using focusing Laue lens. Concerning these instruments, I will discuss their functioning principle, how to achieve a high reflection efficiency, their imaging properties, the current feasibility studies, the technological developments and observation prospects. 2025-02-15T16:25:31Z 33 pages, 18 figures, to be published A chapter of the 3rd edition of the Springer Nature book "Observing Photons in Space - A Guide to Experimental Space Astronomy", 2026 Filippo Frontera http://arxiv.org/abs/2510.25328v2 Analytical Model of Prompt Gamma Timing for Spatiotemporal Emission Reconstruction in Particle Therapy 2026-03-20T09:54:18Z Particle therapy relies on up-to-date knowledge of the stopping power of the patient tissues to deliver the prescribed dose distribution. The stopping power describes the average particle motion, which is encoded in the distribution of prompt-gamma photon emissions in time and space. We reconstruct the spatiotemporal emission distribution from multi-detector Prompt Gamma Timing (PGT) data. Solving this inverse problem relies on an accurate model of the prompt-gamma transport and detection including explicitly the dependencies on the time of emission and detection. Our previous work relied on Monte-Carlo (MC) based system models. The tradeoff between computational resources and statistical noise in the system model prohibits studies of new detector arrangements and beam scanning scenarios. Therefore, we propose here an analytical system model to speed up recalculations for new beam positions and to avoid statistical noise in the model. We evaluated the model for the MERLINO multi-detector-PGT prototype. Comparisons between the analytical model and a MC-based reference showed excellent agreement for single-detector setups. When several detectors were placed close together and partially obstructed each other, intercrystal scatter led to differences of up to 10 % between the analytical and MC-based model. Nevertheless, when evaluating the performance in reconstructing the spatiotemporal distribution and estimating the stopping power, no significant difference between the models was observed. Hence, the procedure proved robust against the small inaccuracies of the model for the tested scenarios. The model calculation time was reduced by 1500 times, now enabling many new studies for PGT-based systems. 2025-10-29T09:43:58Z This is the version of the article before peer review or editing. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1361-6560/ae54ff. 10 pages, 7 figures. V2: update comment Julius Werner Malte Schmidt Francesco Pennazio Jorge Roser Jona Kasprzak Veronica Ferrero Magdalena Rafecas 10.1088/1361-6560/ae54ff http://arxiv.org/abs/2603.03088v2 Using a Stifneck Select Collar$^{\mathrm{TM}}$ for hands-free semiautomatic blood flow measurements: a user study 2026-03-20T08:22:50Z Objective: The percentage of long-term survival in out of hospital cardiac arrest cases is remarkably low. One approach would be to increase the effectiveness of cardiopulmonary resuscitation (CPR), which is currently not measurable in a quantifiable way. The most significant challenge in providing a mobile solution for CPR evaluation is a mobile, hazard free sensor attachment with high usability. Methods: We present a sensor attachment solution usable for semiautomatic ultrasonic (US) Doppler measurements. Components are attached to a Stifneck Select Collar$^{\mathrm{TM}}$ (Laerdal). An inflatable cushion (TR-Band$^{\mathrm{TM}}$, Terumo) allows adjustable contact pressure. A clinical study was conducted in which the system was evaluated based on comfort, pain, sensor support, the viability of Doppler signals, and the absence of skin irritations. Results: The system was utilized in a prospective study involving 102 healthy probands. On a scale between 1 (Low) and 10 (Intense), ratings were 1.19 (SD 0.46), 6.52 (SD 1.78), and 9.95 (SD 0.32) for pain, comfort, and support, respectively. The average duration of application was 31.19 minutes (SD 16.75 minutes). Audible Doppler signals were achieved in 92.2 % of the probands, and Doppler curve evaluation was usable in 73.5 %. No skin irritations were observed. Conclusion: A hands free sensor attachment for a US probe was developed that caused no significant complaints by healthy study volunteers. Medical users assessed its attachment as robust. Significance: With its adjustable positioning and easy attachment, the Stifneck modification can form a basis for a mobile US Doppler device, capable of evaluating carotid artery flow during CPR. 2026-03-03T15:30:48Z 7 pages, 6 figures, 3 tables Reinhard Fuchs Nathalie Sumrah Maximilian N. Möbius-Winkler Georg Stachel Michael Schultz Ulrich Laufs Thomas Neumuth Michael Unger Karsten Lenk http://arxiv.org/abs/2603.19651v1 Characterizing the Radiation Dose to Measurement Accuracy Relationship across Multiple Metrics in Opportunistic Chest CT 2026-03-20T05:21:03Z Objectives: This study aims to characterize the dose-performance relationship for opportunistic CT and disentangle the contributions of segmentation failure and dose-dependent HU bias to performance degradation. Methods: Simulated low-dose CT images at 1-75% of full dose were generated from 50 paired full- and low-dose chest CT scans. An independent dataset of 22 paired PCCT acquisitions at lung cancer screening (LCS) and chest x-ray-equivalent (CXR) dose levels provided parallel real-world evaluation. Multiple quantitative disease metrics were obtained using deep learning-based segmentation followed by quantitative metric extraction. Classification performance was evaluated against full-dose reference standards, with additional analyses isolating the contributions of segmentation error and HU bias. Agreement between dose levels was assessed using Bland-Altman and correlation analyses. Results: Mean HU metrics maintained classification accuracy to CXR-equivalent dose (3%); bias correction improved accuracy from 88% to 96% for hepatic steatosis and from 84% to 90% for sarcopenia. Trabecular bone attenuation maintained 98% accuracy at LCS dose. Volume metrics (cardiomegaly) achieved 94% accuracy at CXR-equivalent dose. Threshold-based metrics required LCS dose for reliable classification; bias correction improved accuracy from 58% to 92%. Coronary artery calcification scoring reached 96% accuracy at LCS dose. In both Mayo and PCCT datasets, agreement analyses demonstrated strong correlation for all metrics except coronary artery calcification. Conclusions: Opportunistic CT is feasible at reduced dose levels though it becomes less robust at ultra-low doses. Distinct failure modes are caused by HU bias or segmentation failure and depend on the clinical task. Providers should be aware of these task-specific limitations when designing opportunistic screening programs. 2026-03-20T05:21:03Z 29 pages, 9 figures Boyuan Li Carolyn C. Chang Jake J. Kim Jia Wang Justin R Tse Natalie S. Lui Haiwei Henry Guo Adam S. Wang http://arxiv.org/abs/2603.19368v1 Beyond the Tumor: Recurrence-Prone Radiomics for Prognostication in Negative PSMA PET/CT scans of Prostate Cancer 2026-03-19T18:02:52Z In patients with biochemical recurrence of prostate cancer and negative PSMA PET/CT, radiomics features extracted from recurrence-prone organs can predict clinical progression and progression-free survival. In a cohort of 132 patients, combining PET/CT radiomics with clinical variables significantly improved prognostic performance (C-index 0.74 vs. 0.65). Model performance was influenced by reader diagnostic certainty and remained robust on external validation. These findings suggest that radiomics from visually negative scans capture subclinical disease and provide added value for risk stratification. 2026-03-19T18:02:52Z Fereshteh Yousefirizi Sara Harsini Mobin Mohebi Ian Alberts Tahir Yusufaly Monica Luo Hamid Abdollahi Elmira Yazdani Soheila Mirabedin Maziar Sabouri Parham Geramifar Peyman Sheikhzadeh Patrick Martineau Don Wilson Francois Benard Carlos Uribe Arman Rahmim http://arxiv.org/abs/2603.18983v1 Machine learning reconstruction of digit bone Raman spectra enables noninvasive transcutaneous detection of systemic osteoporosis 2026-03-19T14:50:23Z Osteoporosis, a major global epidemic, often goes undetected until a fracture occurs, largely due to poor access to screening using gold standard methods, such as dual-energy X-ray absorptiometry (DXA). As a potential nonionizing radiation alternative, we present a transcutaneous spatially offset Raman spectroscopy (SORS) approach combined with machine learning (ML) to recover bone spectra through overlying soft tissue and extract diagnostic information. In a human cadaveric study spanning normal, osteopenic, and osteoporotic donors, we acquired paired Raman measurements from transcutaneous fingers at multiple spatial offsets (0, 3, and 6 mm) and from the corresponding exposed finger bones. Using this paired dataset, supervised machine-learning models were trained to reconstruct exposed-bone Raman spectra from transcutaneous measurements, enabling direct recovery of bone biochemical signatures from transcutaneous tissue. The ML predicted bone spectra preserved physiologically meaningful Raman features and demonstrated statistically significant differences between normal and osteoporotic groups across four key Raman-derived metrics (p < 0.05), representing, to our knowledge, the first demonstration of transcutaneous Raman discrimination between clinically established bone-health categories in a human cadaveric study. The ML-predicted spectra further correlated with distal-radius DXA T-scores (r = 0.73, RMSECV = 1.4), approaching the performance achieved using exposed-bone measurements (r = 0.9, RMSECV = 0.8). Finally, preliminary in vivo measurements from two volunteers revealed clear bone-related transcutaneous spectral features consistent with cadaveric data, supporting translational feasibility. Together, these results establish a foundation for nonionizing radiation, transcutaneous Raman assessment of bone health using supervised spectral extraction from accessible measurement sites 2026-03-19T14:50:23Z Mohammad Hosseini Sadia Afrin Anthony Yosick Hani Awad Andrew J. Berger http://arxiv.org/abs/2507.12632v3 Real-time, inline quantitative MRI enabled by scanner-integrated machine learning: a proof of principle with NODDI 2026-03-19T11:45:31Z Purpose: The clinical feasibility and translation of many advanced quantitative MRI (qMRI) techniques are inhibited by their restriction to 'research mode', due to resource-intensive, offline parameter estimation. This work aimed to achieve 'clinical mode' qMRI, by real-time, inline parameter estimation with a trained neural network (NN) fully integrated into a vendor's image reconstruction environment, therefore facilitating and encouraging clinical adoption of advanced qMRI techniques. Methods: The Siemens Image Calculation Environment (ICE) pipeline was customised to deploy trained NNs for advanced diffusion MRI parameter estimation with Open Neural Network Exchange (ONNX) Runtime. Two fully-connected NNs were trained offline with data synthesised with the neurite orientation dispersion and density imaging (NODDI) model, using either conventionally estimated (NNMLE) or ground truth (NNGT) parameters as training labels. The strategy was demonstrated online in two healthy volunteers (one rescanned) and evaluated offline with synthetic data, testing two diffusion protocols. Results: NNs were successfully integrated and deployed natively in ICE, performing inline, whole-brain, in vivo NODDI parameter estimation in <10 seconds. The proposed workflow was reproducible across protocols, volunteers and rescans. DICOM parametric maps were exported from the scanner for further analyses. Comparisons between NNMLE and NNGT suggested NNMLE parameter estimates to be more consistent with conventional fitting, a finding supported by offline evaluations. Conclusion: Real-time, inline parameter estimation with the proposed generalisable framework resolves a key practical barrier to the potential clinical uptake of advanced qMRI methods, enabling their efficient integration into clinical workflows. Next steps include incorporation of pre-processing methods and evaluation in pathology. 2025-07-16T21:10:29Z 27 pages total, 5 figures (6 pages), 8 supporting materials (9 pages) Samuel Rot Iulius Dragonu Christina Triantafyllou Matthew Grech-Sollars Anastasia Papadaki Laura Mancini Stephen Wastling Jennifer Steeden John S. Thornton Tarek Yousry Claudia A. M. Gandini Wheeler-Kingshott David L. Thomas Daniel C. Alexander Hui Zhang http://arxiv.org/abs/2508.05321v3 Unsupervised Learning for Inverse Problems in Computed Tomography 2026-03-19T09:48:19Z Assume you encounter an inverse problem that shall be solved for a large number of data, but no ground-truth data is available. To emulate this encounter, in this study, we assume it is unknown how to solve the imaging problem of Computed Tomography (CT). An unsupervised deep learning approach is introduced, that leverages the inherent similarities between deep neural network training, deep image prior (DIP) and unrolled optimization schemes. We demonstrate the feasibility of reconstructing images from measurement data by pure network inference, without relying on ground-truth images in the training process or additional gradient steps for unseen samples. Our method is evaluated on the two-dimensional 2DeteCT dataset, showcasing superior performance in terms of mean squared error (MSE) and structural similarity index (SSIM) compared to traditional filtered backprojection (FBP) and maximum likelihood (ML) reconstruction techniques as well as similar performance compared to a supervised DL reconstruction. Additionally, our approach significantly reduces reconstruction time, making it a promising alternative for real-time medical imaging applications. Future work will focus on extending this methodology for adaptability of the projection geometry and other use-cases in medical imaging. 2025-08-07T12:25:48Z 14 pages, 9 Figures Laura Hellwege Johann Christopher Engster Moritz Schaar Thorsten M. Buzug Maik Stille http://arxiv.org/abs/2603.18293v1 Mechanical cues for totipotency and the preneural state: embryo and cancer expanding the frontiers of developmental physics 2026-03-18T21:28:44Z In this article, I advance the idea that physics plays a central role in cell differentiation and makes fundamental contributions to morphogenesis, revealing the totipotent nature of the zygote. Totipotency is a persistent mechanical memory that preserves the biomechanical records of animal morphogenesis. I examine the mechanical and biophysical pathways underlying cell differentiation in embryonic development and cancer, treating them as closely related biological and mechanical processes. Drawing inspiration from evolutionary history, I also propose a biophysical mechanism for the emergence of the animal nervous system. By linking physical principles to cellular differentiation, this review positions mechanobiology as a pillar of innovation with high-impact clinical implications for diseases such as cancer. 2026-03-18T21:28:44Z 48 pages, 2 Figures, Keywords: cell differentiation, default state of neural induction, developmental physics, embryology, totipotency Jaime Cofre