https://arxiv.org/api/tL3Nqz8mnz4VmvtIt1cmznT/gNw 2026-04-09T23:01:55Z 8808 300 15 http://arxiv.org/abs/2601.07881v1 Angled Aortic Cannulation Reduces Cerebral Embolic Transport and Adverse Wall Loading During Cardiopulmonary Bypass: A Patient-Specific Hemodynamic Study 2026-01-11T20:12:36Z Embolic stroke during cardiopulmonary bypass (CPB) is strongly influenced by cannula induced flow disturbances that govern emboli transport and aortic wall loading. This study quantifies how aortic cannula orientation affects embolic distribution and atherosclerotic plaque disruption risk across patient specific, age-dependent aortic anatomies under clinical CPB conditions. A validated computational fluid dynamics and Lagrangian particle tracking (CFD-LPT) framework was applied to four patient-specific aortic models representing pediatric, adolescent, adult, and geriatric anatomies. Two clinically relevant cannula orientations: perpendicular (90 deg) and angled (30 deg), were evaluated under varying blood viscosities (1.5 to 3.5 cP) and embolus sizes (0.5 to 2.5 mm). Aortic branch exit percentage, wall pressure, and wall shear stress (WSS) were quantified. The 30 deg angled cannula reduced embolic transport into the aortic branches by 18 to 50 percent compared with perpendicular cannulation, with the largest reduction observed in the geriatric model. Perpendicular cannulation produced concentrated jet impingement, resulting in significantly elevated posterior wall pressure (24 percent) and up to an 8 fold increase in local WSS. The pediatric anatomy exhibited the highest sensitivity, where decreasing viscosity and increasing embolus size increased branch exit by 8.4 percent and 25 to 44 percent, respectively, consistent with higher particle Stokes numbers and inertial decoupling from the core flow. Angled cannulation redistributes jet momentum along the aortic curvature, weakens jet impingement, reduces localized pressure and wall stress, and limits embolic delivery towards the cerebral circulation. These findings provide mechanistic, patient-specific evidence supporting angled cannula orientation to reduce CPB complications. 2026-01-11T20:12:36Z 22 pages, 7 figures Nafis M. Arefin Bryan C. Good http://arxiv.org/abs/2509.11310v3 Volumetric ultrasound imaging with a sparse matrix array and integrated fiber-optic sensing for robust needle tracking in interventional procedures 2026-01-10T10:06:07Z Accurate visualization of interventional devices, such as medical needles, is essential for the safe and effective guidance of minimally invasive procedures. Ultrasound (US) imaging is widely used for needle guidance, but the two-dimensional nature of most clinical probes limits accurate three-dimensional (3D) localization, particularly of the needle tip. We present a novel system that integrates volumetric US imaging with 3D needle tracking by combining a fiber-optic hydrophone embedded in the needle and a sparse spiral US array. Real-time volumetric imaging was achieved using plane-wave techniques, while precise needle tip tracking was enabled through communication between the probe and hydrophone. The feasibility of the approach was demonstrated using a nerve block training phantom. This proof-of-concept system enables simultaneous volumetric anatomical imaging and 3D needle tip tracking, with strong potential to enhance the efficacy and safety of image-guided interventional procedures. 2025-09-14T15:04:05Z Weidong Liang Javad Rostami Christian Baker Simeon West Athanasios Diamantopoulos Sunish Mathews Adrien E. Desjardins Sebastien Ourselin Laura Peralta Wenfeng Xia http://arxiv.org/abs/2601.05717v1 Inclusion of Inter-crystal Scattering in PET: Analytical Models and Dedicated Reconstruction 2026-01-09T11:01:05Z Inter-crystal scattering (ICS) in Positron Emission Tomography (PET) is commonly regarded as a degradation effect that might compromise the image spatial resolution. In parallel, the inclusion of ICS events has also been recognized as a potential approach to increase PET sensitivity, which could be especially beneficial in scenarios where the latter is a limiting factor, such as very small animal imaging. Several methods for the recovery of ICS events have been proposed, many of which aim to locate the first interaction, i.e., the Compton scattering site, usually limited by their success rate, computational burden or data and training dependency. Conversely, this work proposes a physics-based model for ICS events, leading to analytical expressions of the sensitivity image and the system matrix (required by statistical reconstruction algorithms), without the need to identify the original line of response. After validating the model, the work shows how ICS events can be integrated into a joint image reconstruction algorithm (based on list-mode MLEM) together with conventional PET events, for which dedicated analytical models are also developed. To assess the performance of the proposed approach, Monte-Carlo simulated and experimental data of an image quality phantom were obtained with the MERMAID small-fish PET scanner prototype. Both simulation and experimental results indicate that, while slightly decreasing the recovery coefficient values, the inclusion of ICS clearly reduces statistical noise and improves uniformity. 2026-01-09T11:01:05Z This work has been submitted to the IEEE for possible publication Jorge Roser Hong Phuc Vo Rebecca Kantorek Steven Seeger Magdalena Rafecas http://arxiv.org/abs/2601.05469v1 Group-kernel auto-calibration and group-patch k-space reconstruction: Fast MRI with time-variant B0 kernels partitioned into time-invariant subsets 2026-01-09T01:53:31Z Purpose: Pushing MRI speed further demands more spatially-encoded information captured per unit time, e.g., by superimposing additional field modulations during oversampled readout. However, this can introduce calibration errors and increase reconstruction time. Thus, we propose a continuous field calibration approach and an efficient k-space reconstruction technique. Theory and Methods: Our auto-calibration generalizes GRAPPA kernels to explicitly extract continuous B0 modulation kernels, solving interpolation relationships between two ACS regions differing only in the extra field modulation. The k-space locations sharing the same instantaneous image-space modulation are grouped, so that subsets of time-invariant kernels can be separately estimated, as a generalized solution for Wave-CAIPI/FRONSAC-type scans. This view further inspires a k-space subregion-wise reconstruction technique, as an efficient alternative to conventional hybrid-space reconstruction. At 9.4T, FLASH accelerated by a local B0 coil array and Wave-CAIPI were tested with retrospective undersampling. Results: Artifact-free images were reconstructed, under diverse rapid B0 modulation schemes, reaching maximum acceleration factors of 8-fold in 2D and 14.6-fold in 3D. Some nonlinear gradients modulation schemes reach similar sampling efficiency as linear gradients modulation. The proposed reconstruction shows potentials in reducing reconstruction time. Conclusion: Rapid B0 modulations and widely-adopted parallel imaging can share a common mathematical framework, and consequently, achieve similarly-robust reconstructions. Specifically, for scans using dynamic B0 and static RF kernels, not only signal encoding, but also auto-calibration and reconstruction can be performed in k-space. This paves the way to robustly remove eddy currents, and explore more complex B0 modulation strategies towards ultimate MRI speed. 2026-01-09T01:53:31Z Submitted to Magnetic Resonance in Medicine Rui Tian Martin Uecker Oliver Holder Pavel Povolni Theodor Steffen Klaus Scheffler http://arxiv.org/abs/2601.05448v1 All-optical photoacoustic tomography via beam deflection 2026-01-09T00:29:48Z Photoacoustic imaging (PAI) uniquely combines the advantages of optical contrast with deep tissue penetration capability of acoustic waves, enabling imaging at depths of several centimeters. Conventional photoacoustic imaging methods have relied on pulsed lasers to induce the photoacoustic effect, coupled with arrays of pressure transducers to detect the resulting ultrasound signals. In this work, we propose an alternative all-optical approach that leverages optical deflection to record photoacoustic waves by an array of detection beams. The measured signal is shown to be the Radon transform of the pressure gradients. An optimization-based inversion procedure is used to reconstruct the initial time pressure gradient field. Subsequently, a Galerkin method is used to reconstruct the pressure field from the pressure gradient field. The new modality offers the potential for enhanced sensitivity and reduced signal distortion, advancing the capabilities of photoacoustic imaging beyond traditional transducer-based systems. 2026-01-09T00:29:48Z 30 pages, 8 figures J. Phys. D: Appl. Phys. 59 035401 (2026) Xingchi Yan Siyuan Song Hanxun Jin 10.1088/1361-6463/ae3623 http://arxiv.org/abs/2601.05418v1 Group-patch joint compression for highly accelerated MRI: compressing dynamic B0 and static RF spatial modulations across k-space subregion groups 2026-01-08T22:36:58Z Purpose: To accelerate MRI further, rapid B0 field modulations can be applied during oversampled readout to capture additional physical information, e.g., Wave-CAIPI, FRONSAC, local B0 coils modulations. These methods, however, introduce additional non-Fourier-encoded dimension that cannot be resolved by FFT, posing significant reconstruction challenges particularly in compressed-sensing or neural-network frameworks. Theory and methods: Because B0 modulations vary slowly relative to the oversampled ADC dwell time, we exploit this encoding redundancy by compressing k-space patch-by-patch across subregions, each of which is jointly encoded by a distinct subset of B0 and RF (receive) spatial encoding functions. For each patch, a compression matrix is computed once and reused to compress all patches encoded by the same B0/RF spatial modulations. This can be implemented by feeding subsets of B0 and RF spatial encoding maps into an adapted conventional RF array compression algorithm, mimicking an expanded set of virtual receiver channels. This approach was evaluated on ex-vivo/in-vivo human brain scans at 9.4T/3T. Results: The proposed group-patch joint compression achieves substantially higher compression factors than conventional RF-only compression, while minimally compromising encoding efficiency. Typically, joint compression factors of 11x-20x led to negligible encoding loss, dramatically reducing reconstruction time and peak memory usage. For example, compressed-sensing reconstruction took 1.4-5.1s/2D slice, 177s-10.1min/3D volume, on a high-memory CPU node. Conclusion: Given joint encoding of dynamic B0 and static RF fields, compressing multidimensional k-space patches in separate groups outperforms compressing RF receiver channels alone. This substantially mitigates a fundamental computational bottleneck that arises when combining rapid B0 and RF-receiver modulations. 2026-01-08T22:36:58Z Submitted to Magnetic Resonance in Medicine Rui Tian Klaus Scheffler http://arxiv.org/abs/2601.05410v1 Effect of Right Ventricular Outflow Tract Material Properties on Simulated Transcatheter Pulmonary Placement 2026-01-08T22:19:20Z Finite element (FE) simulations emulating transcatheter pulmonary valve (TPV) system deployment in patient-specific right ventricular outflow tracts (RVOT) assume material properties for the RVOT and adjacent tissues. Sensitivity of the deployment to variation in RVOT material properties is unknown. Moreover, the effect of a transannular patch stiffness and location on simulated TPV deployment has not been explored. A sensitivity analysis on the material properties of a patient-specific RVOT during TPV deployment, modeled as an uncoupled HGO material, was conducted using FEBioUncertainSCI. Further, the effects of a transannular patch during TPV deployment were analyzed by considering two patch locations and four patch stiffnesses. Visualization of results and quantification were performed using custom metrics implemented in SlicerHeart and FEBio. Sensitivity analysis revealed that the shear modulus of the ground matrix (c), fiber modulus (k1), and fiber mean orientation angle (gamma) had the greatest effect on 95th %ile stress, whereas only c had the greatest effect on 95th %ile Lagrangian strain. First-order sensitivity indices contributed the greatest to the total-order sensitivity indices. Simulations using a transannular patch revealed that peak stress and strain were dependent on patch location. As stiffness of the patch increased, greater stress was observed at the interface connecting the patch to the RVOT, and stress in the patch itself increased while strain decreased. The total enclosed volume by the TPV device remained unchanged across all simulated patch cases. This study highlights that while uncertainties in tissue material properties and patch locations may influence functional outcomes, FE simulations provide a reliable framework for evaluating these outcomes in TPVR. 2026-01-08T22:19:20Z 22 pages, 5 figures, 3 tables, Preprint submitted to Journal of the Mechanical Behavior of Biomedical Materials Jalaj Maheshwari Wensi Wu Christopher N. Zelonis Steve A. Maas Kyle Sunderland Yuval Barak-Corren Stephen Ching Patricia Sabin Andras Lasso Matthew J. Gillespie Jeffrey A. Weiss Matthew A. Jolley http://arxiv.org/abs/2601.05348v1 Feasibility of a General-Purpose Deep Learning Dose Engine: A Multi-Site Validation Study 2026-01-08T19:55:33Z Conventional radiotherapy dose calculation algorithms are often computationally slow and non-differentiable, creating bottlenecks for online adaptive radiotherapy (ART) and limiting end-to-end automatic planning. Deep learning provides consistent inference performance and a differentiable framework essential for rapid optimization. In this study, we developed a generalized, site-independent deep learning dose engine using a beamlet-based input strategy. This establishes a computationally consistent and differentiable module that enables end-to-end training for autoplanning while maintaining accuracy across diverse geometries. A dataset of 3,600 plans from 120 patients across six anatomical sites was used to train two 3D convolutional neural networks, a standard U-Net and a Cascade U-Net, to predict 3D dose distributions from CT images and divergent MLC/jaw projections. Performance was validated via 3D gamma analysis on an independent cohort of 60 VMAT plans. The optimal model (U-Net with MAE loss) achieved a mean gamma passing rate of $98.9 \pm 1.6\%$ (3%/2mm, 10% threshold). Performance remained robust across all sites (passing rates $>98\%$), demonstrating that the beamlet-based strategy generalizes effectively to complex geometries without site-specific training. These results indicate that a single, site-independent model can calculate radiotherapy dose distributions with clinical accuracy. This differentiable engine is highly suitable for integration into end-to-end automatic planning, online ART, and secondary dose verification workflows. 2026-01-08T19:55:33Z Yao Zhao Ka Ho Tam Raphael Douglas Kyuhak Oh Xin Wang Ergys Subashi Jinzhong Yang Laurence Court Dong Joo Rhee http://arxiv.org/abs/2601.05063v1 Quantitative mapping from conventional MRI using self-supervised physics-guided deep learning: applications to a large-scale, clinically heterogeneous dataset 2026-01-08T16:08:58Z Magnetic resonance imaging (MRI) is a cornerstone of clinical neuroimaging, yet conventional MRIs provide qualitative information heavily dependent on scanner hardware and acquisition settings. While quantitative MRI (qMRI) offers intrinsic tissue parameters, the requirement for specialized acquisition protocols and reconstruction algorithms restricts its availability and impedes large-scale biomarker research. This study presents a self-supervised physics-guided deep learning framework to infer quantitative T1, T2, and proton-density (PD) maps directly from widely available clinical conventional T1-weighted, T2-weighted, and FLAIR MRIs. The framework was trained and evaluated on a large-scale, clinically heterogeneous dataset comprising 4,121 scan sessions acquired at our institution over six years on four different 3 T MRI scanner systems, capturing real-world clinical variability. The framework integrates Bloch-based signal models directly into the training objective. Across more than 600 test sessions, the generated maps exhibited white matter and gray matter values consistent with literature ranges. Additionally, the generated maps showed invariance to scanner hardware and acquisition protocol groups, with inter-group coefficients of variation $\leq$ 1.1%. Subject-specific analyses demonstrated excellent voxel-wise reproducibility across scanner systems and sequence parameters, with Pearson $r$ and concordance correlation coefficients exceeding 0.82 for T1 and T2. Mean relative voxel-wise differences were low across all quantitative parameters, especially for T2 ($<$ 6%). These results indicate that the proposed framework can robustly transform diverse clinical conventional MRI data into quantitative maps, potentially paving the way for large-scale quantitative biomarker research. 2026-01-08T16:08:58Z 30 pages, 13 figures, full paper Jelmer van Lune Stefano Mandija Oscar van der Heide Matteo Maspero Martin B. Schilder Jan Willem Dankbaar Cornelis A. T. van den Berg Alessandro Sbrizzi http://arxiv.org/abs/2601.05045v1 Dosimetric Impact of Hidden Input Parameters in Inverse Optimization Algorithms for GYN HDR Brachytherapy 2026-01-08T15:51:24Z Inverse optimization (IO) algorithms are used in GYN HDR brachytherapy planning, with user parameter settings embedded in commercial TPS. To examine the dosimetric influence of hidden input parameters in three IO algorithms-IPSA, HIPO, and MCO-for GYN HDR brachytherapy across two applicator types. In-house implementations of IPSA, HIPO, and MCO were implemented and evaluated against retrospectively generated commercial TPS plans (Oncentra Brachy) using identical clinical input parameters across 24 cervical cancer cases (18 T&O; 6 T&O+Needles (T&O+N)). Each IO algorithm was assessed using 1k combinations of hidden parameters (e.g., dwell-time modulation constraints, convergence thresholds). Cumulative DVH curves and dosimetric indices (HR-CTV D98/D90, OAR D2cc) were compared with commercial plans. Standard deviations (SD) of DVH differences were used to characterize sensitivity to hidden parameters. For HR-CTV, SD values in T&O+N cases reached 23.0 Gy and 7.1 Gy for MCO and HIPO, respectively, with corresponding average values of 55.8 Gy and 19.7 Gy. In T&O cases, HR-CTV SD values reached 4.9 Gy and 3.3 Gy for HIPO and IPSA, respectively, with average values of 20.1 Gy and 8.6 Gy. MCO exhibited the highest sensitivity, followed by HIPO and IPSA. T&O+N cases showed greater sensitivity than T&O cases. Absolute differences in HR-CTV D90 (D98) relative to commercial algorithms reached up to 33.3 Gy (28.4) for T&O+N cases and 10.8 Gy (8.5) for T&O cases. For OARs, absolute D2cc differences in T&O+N (T&O) cases reached up to 8.6 Gy (2.3) for rectum, 17 Gy (10.2) for bladder, 14.8 Gy (3.9) for sigmoid, and 7.0 Gy (8.1) for bowel. Hidden input parameter settings significantly impact on GYN HDR plans, with target coverage up to 28.4 Gy across IO algorithms for both T&O and T&O+N cases. The findings in this study shown the potential to improve plans through hidden input parameter optimization. 2026-01-08T15:51:24Z 4 pages, 3 figures, 3 tables YeongHyeon Park Shiqin Su Sarath Vijayan Zhiqian Henry Yu Mandy Cunningham Yusung Kim http://arxiv.org/abs/2601.04821v1 Bi-level Multi-criteria Optimization for Risk-informed Radiotherapy 2026-01-08T10:57:53Z In radiation therapy (RT) treatment planning, multi-criteria optimization (MCO) supports efficient plan selection but is usually solved for population-based dosimetric criteria and ignores patient-specific biological risk, potentially compromising outcomes in high-risk patients. We propose risk-guided MCO, a one-shot method that embeds a clinical risk model into conventional MCO, enabling interactive navigation between dosimetric and biological endpoints. The proposed algorithm uses a special order relation to fuse the classical MCO sandwiching algorithm with bi-level optimization, restricting the Pareto set to plans that achieve improvement in the secondary risk objective for user-defined, acceptable loss in primary clinical objectives. Thus, risk-guided MCO generates risk-optimized counterparts of clinical plans in a single run rather than by sequential or lexicographic planning. To assess the performance, we retrospectively analyzed 19 lung cancer patients treated with RT. The endpoint was the risk of grade 2+ radiation pneumonitis (RP), modeled using bootstrapped stepwise logistics regression with interaction terms, including baseline lung function, smoking history, and dosimetric factors. The risk-guided plans yielded a mean reduction of 8.0% in total lung V20 and 9.5% in right lung V5, translating into an average RP risk reduction of 7.7% (range=0.3%-20.1%), with small changes in target coverage (mean -1.2 D98[%] for CTV) and modest increase in heart dose (mean +1.74 Gy). This study presents the first proof-of-concept for integrating biological risk models directly within multi-criteria RT planning, enabling an interactive balance between established population-wide dose protocols and individualized outcome prediction. Our results demonstrate that the risk-informed MCO can reduce the risk of RP while maintaining target coverage. 2026-01-08T10:57:53Z Mara Schubert Katrin Teichert Zhongxing Liao Thomas Bortfeld Ali Ajdari http://arxiv.org/abs/2503.20107v2 Federated Learning: A new frontier in the exploration of multi-institutional medical imaging data 2026-01-07T21:43:09Z Artificial intelligence has transformed the perspective of medical imaging, leading to a genuine technological revolution in modern computer-assisted healthcare systems. However, ubiquitously featured deep learning (DL) systems require access to a considerable amount of data, facilitating proper knowledge extraction and generalization. Access to such extensive resources may be hindered due to the time and effort required to convey ethical agreements, set up and carry the acquisition procedures through, and manage the datasets adequately with a particular emphasis on proper anonymization. One of the pivotal challenges in the DL field is data integration from various sources acquired using different hardware vendors, diverse acquisition protocols, experimental setups, and even inter-operator variabilities. In this paper, we review the federated learning (FL) concept that fosters the integration of large-scale heterogeneous datasets from multiple institutions in training DL models. In contrast to a centralized approach, the decentralized FL procedure promotes training DL models while preserving data privacy at each institution involved. We formulate the FL principle and comprehensively review general and specialized medical imaging aggregation and learning algorithms, enabling the generation of a globally generalized model. We meticulously go through the challenges in constructing FL-based systems, such as data and model heterogeneities across the institutions, resilience to potential attacks on data privacy, and the variability in computational and communication resources among the entangled sites that might induce efficiency issues of the entire system. Finally, we explore the up-to-date open frameworks for rapid FL-based algorithm prototyping, comprehensively present real-world implementations of FL systems and shed light on future directions in this intensively growing field. 2025-03-25T23:08:36Z Dominika Ciupek Maciej Malawski Tomasz Pieciak http://arxiv.org/abs/2601.03827v1 Objective comparison of auditory profiles using manifold learning and intrinsic measures 2026-01-07T11:47:32Z Assigning individuals with hearing impairment to auditory profiles can support a better understanding of the causes and consequences of hearing loss and facilitate profile-based hearing-aid fitting. However, the factors influencing auditory profile generation remain insufficiently understood, and existing profiling frameworks have rarely been compared systematically. This study therefore investigated the impact of two key factors - the clustering method and the number of profiles - on auditory profile generation. In addition, eight established auditory profiling frameworks were systematically reviewed and compared using intrinsic statistical measures and manifold learning techniques. Frameworks were evaluated with respect to internal consistency (i.e., grouping similar individuals) and cluster separation (i.e., clear differentiation between groups). To ensure comparability, all analyses were conducted on a common open-access dataset, the extended Oldenburg Hearing Health Record (OHHR), comprising 1,127 participants (mean age = 67.2 years, SD = 12.0). Results showed that both the clustering method and the chosen number of profiles substantially influenced the resulting auditory profiles. Among purely audiogram-based approaches, the Bisgaard auditory profiles demonstrated the strongest clustering performance, whereas audiometric phenotypes performed worst. Among frameworks incorporating supra-threshold information in addition to the audiogram, the Hearing4All auditory profiles were advantageous, combining a near-optimal number of profile classes (N = 13) with high clustering quality, as indicated by a low Davies-Bouldin index. In conclusion, manifold learning and intrinsic measures enable systematic comparison of auditory profiling frameworks and identify the Hearing4All auditory profile as a promising approach for future research. 2026-01-07T11:47:32Z Chen Xu Birger Kollmeier Lena Schell-Majoor http://arxiv.org/abs/2508.11100v3 Full-Wave Modeling of Transcranial Ultrasound using Volume-Surface Integral Equations and CT-Derived Heterogeneous Skull Data 2026-01-07T03:53:49Z Transcranial ultrasound therapy uses focused acoustic energy to induce therapeutic bioeffects in the brain. Ultrasound must be transmitted through the skull, which is highly attenuating and heterogeneous, causing beam distortion, reducing focal pressure, and shifting the target location. Computational models are frequently used to predict beam aberration, assess cranial heating, and correct the phase of ultrasound transducers. These models often rely on computed tomography (CT) images to build patient-specific geometries and estimate skull acoustic properties. However, the coarse voxel resolution of CT limits accuracy for differential equation solvers at ultrasound frequencies. This paper presents an efficient numerical method based on volume-surface integral equations to model full-wave acoustic propagation through heterogeneous skull bone. We show that our approach effectively simulates transcranial ultrasound, even when using the original CT voxels as the computational mesh, where the 0.5 mm voxel length is relatively coarse compared to the shortest wavelength of 3 mm. The method is validated against a high-resolution boundary element model using an averaged skull representation. Simulations using a CT-based skull model and a bowl transducer reveal significant beam distortion of 7.8 mm attributed to the skull's heterogeneous acoustical properties. 2025-08-14T22:39:24Z Alberto Almuna-Morales Danilo Aballay Pierre Gélat Reza Haqshenas Elwin van 't Wout 10.1016/j.ultras.2026.107954 http://arxiv.org/abs/2601.03224v1 Open-Source Coil Matching Toolbox for Magnetic Stimulation and Other Electromagnetics (COMATOSE) 2026-01-06T18:12:33Z The coil in transcranial magnetic stimulation (TMS) determines the spatial shape of the electromagnetic field in the head, which structures are concurrently activated, and how focal stimulation is. Most of the readily available coils have been designed intuitively instead of systematic mathematical-physical optimization as there were no methods available at the time. Previous research however demonstrated that these coils are far from optimum, e.g., for pulse energy or efficiency, and leave substantial room for lots of improvements. Techniques for rigorous mathematical optimization have been developed but are only available to very few groups worldwide. This paper presents an open-source toolbox, COMATOSE, to change that situation and make these methods available to a wider community. It incorporates the fundamental formalisms and offers vector space decomposition as well as base mapping as an explicit forward method, which is computationally less demanding than iterative computational optimization but can also form the initial solution for a subsequent optimization run if desired. 2026-01-06T18:12:33Z 5 pages, 1 figure Max Koehler Stefan Goetz