https://arxiv.org/api/K8A/nauJaQ7nvb3ab3nog9N/bd82026-06-10T01:44:52Z89593015http://arxiv.org/abs/2604.10174v2Combined photon-proton modeling of radiation-induced brain imaging changes supports variability in proton relative biological effectiveness and increased periventricular radiosensitivity2026-06-02T20:43:37ZPurpose: Recent proton-only investigations of radiation-induced contrast enhancements (RICE) in brain tumor patients indicated variability in proton relative biological effectiveness (RBE) and increased radiosensitivity of the periventricular region (PVR). Because RBE is defined relative to a reference radiation, these studies required assumptions on the photon dose-response relationship. This study aimed to validate proton RBE variability and PVR radiosensitivity using predictive modeling of RICE in a combined photon-proton cohort. Methods and Materials: Predictive models for RICE detected on follow-up magnetic resonance imaging were developed in 152 intracranial tumor patients treated with photons or protons. Logistic regression was applied at the voxel level to model spatial occurrence and at the patient level to model incidence. A clinical RBE model was derived from voxel-wise comparisons of estimated risk between photon and proton irradiation. Results: In total, 128 RICE of various grades occurred in 64 patients. Voxel-level modeling validated absorbed dose (D), D multiplied by dose-averaged linear energy transfer (LETd) for proton therapy, and PVR as independent predictors of RICE. The model implied a variable proton RBE described by RBE=1+m$\cdot$LETd, with m=0.10 $μ$m/keV. At the patient level, the PVR D2ml based on this RBE achieved the highest predictive performance. Conclusions: RICE was spatially associated with dose and PVR proximity across photon and proton therapy, with an additional LET-dependent component after proton therapy. The cross-modality framework validates proton RBE variability against an observed photon reference rather than predefined reference assumptions, and supports PVR radiosensitivity as modality-independent. Accounting for variable proton RBE and the PVR as an organ at risk may improve risk assessment and mitigation of radiation-induced side effects.2026-04-11T12:02:04Z34 pages, 6 figures, 10 tables. Supplementary data are provided at the end of the manuscriptMartina PalkowitschLarissa S. KilianFabian HenningsArmin LührJustus ThiemArne GreyRebecca BütofAnnekatrin SeidlitzEsther G. C. TroostMechthild KrauseSteffen Löckhttp://arxiv.org/abs/2606.03978v1The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification2026-06-02T17:56:51ZThis study presents the first clinical integration and experimental demonstration of a nozzle-mounted Compton camera prompt gamma imaging (PGI) system for in vivo proton range verification. Four position-sensitive solid-state Compton camera modules, each containing four cadmium zinc telluride (CdZnTe) detector crystals, were integrated into a modified range shifter mounted directly on the treatment nozzle of a clinical proton therapy gantry. This compact fixed-geometry configuration maintained alignment with the proton beam axis throughout irradiation and enabled stable synchronized data acquisition during pencil-beam scanning delivery. The system was evaluated under realistic clinical proton beam delivery conditions using single-energy and spread-out Bragg peak (SOBP) irradiations at gantry angles of 90° and 270°, delivered doses of 2 Gy and 7.5 Gy, and controlled distal range shifts of up to 10 mm. Prompt gamma events were reconstructed into three-dimensional emission distributions using a physics-based Compton scatter reconstruction framework. The system operated reliably during all irradiations and produced reproducible prompt-gamma localization across repeated measurements. Reconstructed emission distributions remained geometrically consistent across gantry angles and demonstrated sensitivity to controlled distal range perturbations, with measurable upstream shifts of the emission hotspot corresponding to reduced proton penetration depth. These results demonstrate the feasibility of a clinically integrated nozzle-mounted quad-camera Compton PGI system for detecting millimeter-scale proton range variations during beam delivery and represent an important step toward clinically deployable prompt gamma-based in vivo treatment verification in proton therapy.2026-06-02T17:56:51Z10 pages, 9 figures. Submitted to IEEE Transactions on Medical ImagingFarshad SafaviStephen W. PetersonSina MossahebiAnanta ChaliseVijay R. SharmaMatthias K. GobbertJerimy C. PolfLei Renhttp://arxiv.org/abs/2606.03562v1Magnet-Free Proton Therapy with 4D Pencil Beam Delivery Optimisation2026-06-02T12:29:12ZObjective. Motion management is a critical challenge in proton therapy for mobile tumours. This study aims to develop and evaluate a novel four-dimensional (4D) pencil beam delivery strategy that incorporates respiratory motion into a dynamic treatment plan to improve dose conformity and treatment efficiency. Approach. To assess this 4D pencil beam delivery strategy, a mobile phantom was used. The generated 4D treatment plans were assessed with various scanner configurations, including gantry-free and magnet-free scanner heads. For each setup, the treatment time, dose conformity, and robustness against irregular breathing patterns were quantified. The influence of scanner head design and patient-specific motion irregularities on overall plan quality was evaluated. Main Results. The 4D planning tool generated treatment plans that achieved clinically acceptable dose distributions across all configurations. In magnet-free configurations, static beam operation substantially increased treatment time and reduced dose conformity. In contrast, configurations using a single scanner magnet, without a gantry, maintained acceptable conformity within practical treatment times. Significance. The proposed 4D delivery strategy demonstrates feasibility for treating mobile targets with simplified, gantry-free and magnet-free scanner designs. Further improvements could be achieved by synchronising the patient's breathing with 4D delivery, which may enhance dose accuracy during irregular or interrupted breathing. By reducing system complexity while preserving dosimetric performance, this approach offers a pathway toward more accessible and cost-effective proton beam therapy for motion-affected tumours.2026-06-02T12:29:12ZNair N von MuehlenenFlorentin BiederYe ZhangPhilippe C Cattinhttp://arxiv.org/abs/2606.02044v1Realistic noise synthesis reduces bias and improves tissue microstructure estimation with supervised machine learning2026-06-01T10:35:33ZDiffusion MRI enables non-invasive probing of tissue microstructure, but accurate parameter estimation is challenged by noise-related effects. In supervised machine learning frameworks trained on simulated data, discrepancies between the noise characteristics of simulated and acquired signals introduce a form of covariate shift, whereby the input signal distribution differs between training and inference. We investigated the impact of this mismatch on microstructure parameter estimation and propose a realistic noise synthesis (RNS) framework to mitigate it. RNS incorporates both the Rician expectation and the effective post-processing noise variance into simulated training signals. The Rician expectation was modelled using a noise standard deviation estimated with MPPCA, while the effective standard deviation was derived from spherical harmonic residuals of preprocessed data. The method was evaluated using the cylinder-zeppelin and the SANDI models on simulated datasets across multiple SNR levels and on in vivo diffusion data with repeated acquisitions. Sensitivity to noise misestimation was also assessed. Ignoring magnitude-induced noise effects during training produced systematic, SNR-dependent parameter bias, particularly at low SNR. Incorporating the Rician expectation substantially reduced bias to the level of noise-aware nonlinear least-squares fitting. Modelling the effective standard deviation further improved precision. Performance was largely independent of regression architecture but sensitive to accurate noise estimation. These findings demonstrate that realistic noise modelling in simulated training data mitigates signal-domain covariate shift and is essential for unbiased supervised microstructure estimation, particularly in low-SNR regimes associated with high b-values or high spatial resolution.2026-06-01T10:35:33ZBradley G. KaratMaëliss JallaisAli R. KhanSantiago Aja-FernándezJelle VeraartMarco Palombohttp://arxiv.org/abs/2605.05713v2Quantifying thermal-signature equivalence in infrared breast thermography using a modified Pennes bioheat model2026-05-31T02:18:18ZInfrared breast thermography provides a noninvasive measurement of skin-surface temperature, but the relation between surface thermal patterns and intratumoral physiology is limited by heat diffusion and thermal screening. Here we study a steady-state modified Pennes bioheat model in a two-dimensional multilayer breast-tissue cross-section containing a finite-sized tumor with spatially heterogeneous perfusion. We compare four idealized perfusion patterns: uniform, rim-enhanced, necrotic-core, and anisotropic perfusion. To assess how well these internal differences are preserved at the surface, we compare the full temperature-rise profiles using an $L^2$ distance and define thermal-signature equivalence through an observational tolerance. The results show that distinct perfusion patterns can generate clearly different internal temperature fields, while their surface signatures may become much more similar after propagation through the surrounding tissue. Tests with noisy surface profiles indicate that this equivalence classification is sensitive to the assumed form of profile-level uncertainty. After matching the tumor-averaged perfusion, the radially heterogeneous cases become much closer to the uniform case, whereas the anisotropic case remains more distinguishable because of its directional structure. Increasing tumor depth promotes thermal-signature equivalence, whereas increasing tumor diameter enhances surface distinguishability;a depth--diameter map shows the competition between these two effects. Fat-layer thickness and mild outer-surface deformation modify the surface profiles, but their influence is secondary over the parameter ranges considered here. These results highlight a limitation of static breast thermography: a surface thermal anomaly can be detected without uniquely identifying the underlying intratumoral perfusion structure.2026-05-07T05:57:10Z33 pages, 10 figuresRoni MuslimRamacos FardelaTista Artu Indra Kusumahttp://arxiv.org/abs/2606.00922v1A Machine-to-Machine Knowledge-Guided LLM Agent for Generalizable Radiotherapy Treatment Planning2026-05-30T23:14:30ZIn this work, we propose a prototype machine-to-machine (M2M) knowledge-guided Large Language Model (LLM) framework for automated radiotherapy treatment planning. In the proposed paradigm, Treatment Planning Parameter (TPP) distribution knowledge discovered by a Deep Reinforcement Learning (DRL) agent is transferred to an LLM agent through in-context learning, enabling autonomous iterative planning without human intervention. While standard LLM-based planning often lacks physical intuition and struggles with convergence, the integration of DRL-derived guidance constrains the agent to a physically valid parameter space. Experimental evaluations are performed across three diverse planning scenarios: basic prostate cases, complex prostate configurations with increased organ-at-risk (OAR) constraints, and liver cases. The evaluation results demonstrate that the guided LLM agent consistently achieves optimal planning scores while significantly reducing the number of iterations compared to unguided planning. Analysis of the final TPP configurations reveals that the agent successfully learns a hierarchical priority of objectives, effectively restoring a logical "cause-and-effect" relationship between parameter tuning and dosimetric outcomes. Crucially, this prototype framework exhibits robust generalizability, maintaining high planning quality regardless of specific patient anatomy, treatment site, or initial plan quality. By bridging the specialized optimization of DRL with the adaptive reasoning of LLMs, this M2M framework establishes a scalable foundation towards generalizable autonomous treatment planning, ultimately benefiting clinical practice in realistic environments.2026-05-30T23:14:30Z10 pages, 6 figuresMd Mainul AbrarXun JiaYujie Chihttp://arxiv.org/abs/2510.11060v2Basis for a hands free blood flow measurement with automated vessel focus2026-05-29T15:56:52ZCardiopulmonary resuscitation (CPR) is an essential tool to ensure oxygen supply during cardiac arrest, yet not quantifiable to this day. Low-quality chest compressions or wrong pressure placement go unnoticed. This paper presents a solution for the quantification of blood flow to guide first responders in their efforts. An approach for automated vessel identification with three different steps was developed, featuring a new sensor probe for ultrasonic measurements with non-symmetrically angled piezo ceramics. The probe was used with prototype ultrasound hardware for Pulsed Wave Doppler (PW Doppler) in a phantom. Initial measurements evaluated sensor vessel alignment at different sensor positions by examining Doppler results with a large sample volume during periodic flow. Afterward, an iterative mode was used for depth-dependent frequency measurements with score calculation of flow periodicity and power. The configuration with the best score was used for a prolonged monitoring mode. Initial mode and iterative mode aligned with ultrasound imaging regarding the best position and vessel depth. Simultaneous flow-sensor data and flow values of monitoring mode calculated via Doppler substitution showed a minimum correlation coefficient of 0.98, a minimum R2 of 0.96, and an average root mean square error of 3.84 ml/s. With the proposed hardware and software solutions, a basis for future developments was made, which could lead to a fully automated vessel identification and blood flow calculation during CPR. When used in emergencies, a miniaturized device could provide vital information about CPR efficiency that has yet to be included in the therapy of people during cardiac arrest.2025-10-13T06:50:12ZReinhard FuchsNathalie SumrahJohannes SchwerdtMichael UngerGeorg StachelMichael SchultzKarsten LenkThomas Neumuthhttp://arxiv.org/abs/2605.30172v1A Lumped-Element Electrical Model of the Human Head for Brain-Oriented Applications2026-05-28T16:21:51ZIn this work, we present a compact surrogate circuit for electro-quasi-static (EQS) head modeling. A three-shell geometry (brain, skull, scalp) is considered, and each layer is modeled through radial and tangential pathways, implemented as RC branches. Frequency-dependent tissue conductivity and permittivity are mapped into dispersive resistive and capacitive elements. The model is validated against a semi-analytical spherical-harmonics reference solution over multiple geometrical configurations and operating frequencies, demonstrating good agreement. Neglecting dispersion and capacitive pathways can lead to an overestimation of scalp potentials over the considered frequency range, highlighting the need for dispersive RC circuit modeling.2026-05-28T16:21:51Z4 pages, 4 figures. To appear in the proceedings of the APS March Meeting 2026, Detroit, MichiganAngelo FacciaErmanno CitraroFrancesco P. Andriullihttp://arxiv.org/abs/2605.29593v1CT Imaging with Helium and Carbon Ions for Hadron Therapy2026-05-28T08:34:29ZObjective: To perform a comprehensive comparative analysis of proton, helium-ion, and carbon-ion computed tomography (CT) as direct imaging modalities for hadron therapy treatment planning, focusing on Relative Stopping Power (RSP) reconstruction accuracy and patient radiation dose.
Approach: High-fidelity Monte Carlo simulations were conducted using the GATE/Geant4 platform to model a standard CTP404 phantom. RSP maps were reconstructed using an iterative Richardson-Lucy deconvolution algorithm. Imaging performance was evaluated by comparing reconstructed RSP values against ground truth data for various tissue-equivalent inserts, while integral doses were estimated for a human head geometry.
Main results: All investigated particle modalities demonstrated a significant dose reduction compared to conventional X-ray CT protocols (which are approximately 40 mGy). The estimated imaging doses were 1.6 mGy for protons, 3.9 mGy for helium ions, and 22.7 mGy for carbon ions. In terms of accuracy, carbon-ion imaging achieved the highest fidelity for soft-tissue materials (mean absolute error <0.5\%). Helium ions offered a balanced performance with sub-1\% errors for most materials and a dose burden significantly lower than carbon ions. Protons exhibited the widest range of RSP deviations (-1.8\% to +3.1\%).
Significance: Direct particle imaging eliminates the systematic uncertainties inherent in photon-to-hadron conversion. While carbon ions provide superior RSP reconstruction precision essential for complex treatment plans in heterogeneous anatomy, helium and proton imaging offer exceptional dose sparing, making them particularly advantageous for pediatric patients and frequent adaptive replanning scenarios.2026-05-28T08:34:29Z18 pages, 7 figuresZsófia JóleszGábor BíróGábor PappGergely Gábor Barnaföldihttp://arxiv.org/abs/2605.29419v1Coupling Spectrum Estimation and Single Energy Material Decomposition via X-ray Grating Interferometry2026-05-28T06:13:55ZDark-field imaging based on grating interferometry is an emerging X-ray modality in medical imaging, which is particularly capable of providing complementary diagnostic information by visualizing the microstructural properties of lung tissue. However, quantitative dark-field imaging remains fundamentally challenged by beam hardening, which arises from the energy-dependent fringe visibility under polychromatic illumination. The resulting artifacts substantially degrade the quantitative accuracy of dark-field images. In this work, motivated by our key observation of an intrinsic similarity between the X-ray energy spectrum and the system-related coupling spectrum, we propose a unified framework to simultaneously and independently estimate both spectra. By measuring the transmission associated with the zeroth- and first-order components of the phase-stepping curve using solid step-wedge phantoms, the two spectra are robustly estimated via an expectation-maximization algorithm. The recovered spectra are subsequently incorporated into a physics-based correction model to mitigate beam-hardening-induced artifacts in dark-field imaging effectively. Furthermore, leveraging the inherent availability of two independent spectra within X-ray grating interferometry, we introduce a single-energy material decomposition method that achieves basis material imaging without dual-energy scans. Wave-optical simulations and experiments demonstrate accurate spectrum estimation, effective dark-field signal correction, and reliable material decomposition. Consequently, the proposed framework extends the diagnostic potential of X-ray grating interferometry beyond pulmonary imaging, facilitating broader applications in medical imaging.2026-05-28T06:13:55ZLongchao MenPeiyuan GuoJincheng LuYan XuHongxia YinZhenchang WangLi ZhangZhentian Wanghttp://arxiv.org/abs/2605.29195v1Multi-Kernel TOF-PET Image Reconstruction Using ADMM2026-05-28T00:10:48ZTime-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing attention. However, to fully exploit the latent potential of multi-kernel TOF-PET, new iterative image reconstruction methods are required. In this study, assuming that the events are labeled with the appropriate kernels, we propose an alternating direction method of multipliers (ADMM) for multi-kernel TOF-PET reconstruction, termed TOF-decomp ADMM. As the convergence speed of the TOF-PET log-likelihood depends on the CTR, the proposed method splits the fast- and slow-CTR log-likelihood terms and optimizes them separately under a constraint. This strategy explicitly balances the contributions of fast- and slow-CTR components and enables early stopping at iterations that yield improved contrast-noise trade-offs compared with conventional methods. We validated the proposed method using brain and image quality phantom simulations, demonstrating improved contrast-noise characteristics from a more stabilized convergence. By addressing the convergence imbalance inherent to multi-kernel TOF-PET, this work establishes a framework for exploiting the timing information available in emerging detector technologies.2026-05-28T00:10:48Z14 pages, 13 figures. Submitted to IEEE Transactions on Radiation and Plasma Medical SciencesKibo OteFumio HashimotoYuya OnishiRyosuke OtaMaxime ToussaintFrancis Loignon-Houlehttp://arxiv.org/abs/2605.29133v1Improving depth-resolution, in-plane contrast, and reducing non-uniformity artifacts for wide-angle DBT2026-05-27T21:56:18ZPurpose: This work aims to develop an image reconstruction algorithm for wide-angle digital breast tomosynthesis (DBT) that has improved depth resolution and in-plane contrast while reducing non-uniformity artifacts. Approach: The image reconstruction algorithm is an extension of our prior work on sparsity-regularized iterative image reconstruction. The algorithm is performed in two stages as explained in a prior work. The first stage consists of a low-resolution reconstruction that exploits sparsity for quantitative accuracy. In this work, this first stage is augmented with a formulation that includes the estimation of a "background" image, which absorbs low-frequency artifacts that cause image non-uniformity. Results: The new algorithm is demonstrated on a patient case for which the data are acquired on a wide-angle DBT system. Conclusion: The results on the shown case indicate that the algorithm design goals have been met, but additional empirical results and task-based assessment are needed to strengthen this conclusion.2026-05-27T21:56:18ZSubmitted to the Journal of Medical Imaging special issue: Pioneers in Medical Imaging: Honoring the Memory of Harrison H. Barrett, PhDEmil Y. SidkyAdrian A. SanchezJohn Paul PhillipsZheng ZhangDan XiaIngrid S. ReiserXiaochuan Panhttp://arxiv.org/abs/2605.28687v1Cross-modal characterization of infant cry: validation of a chest-surface accelerometer in extracting acoustic vocal function measures2026-05-27T16:17:25ZBackground: Infant cry acoustics provide a promising window into early neurodevelopment and may serve as scalable biomarkers for neurodevelopmental disorders. However, conventional microphone-based recordings are highly susceptible to environmental noise and raise privacy concerns in real-world clinical settings. Chest-surface accelerometers may offer a robust alternative by capturing vibrations directly from the larynx.
Methods: We evaluated the validity of a chest-mounted accelerometer (ACC) for infant cry analysis by comparing acoustic features derived from ACC and simultaneously recorded microphone (MIC) signals during routine vaccination visits. The final sample included 85 infants (41 at 4 months; 44 at 12 months) from a diverse pediatric population. Seven vocal measures were extracted from both modalities, including fundamental frequency (F0), jitter, shimmer, cepstral peak prominence (CPP), and harmonics-to-noise ratio (HNR). Agreement and consistency between modalities was assessed using intraclass correlation coefficients (ICCs).
Results: F0 demonstrated excellent agreement between ACC and MIC recordings (ICC > 0.94). Jitter measures also showed good-to-excellent agreement, while CPP demonstrated moderate agreement. Shimmer and HNR showed lower absolute agreement and systematic bias between modalities, reflecting possible differences in signal transmission and noise sensitivity.
Conclusion: In summary, chest-surface accelerometers can reliably capture several clinically relevant acoustic features of infant cry, particularly temporal measures of F0 and jitter. This approach offers a noise-robust and privacy-preserving alternative to microphone-based recordings, supporting its potential use in scalable clinical and developmental research applications.2026-05-27T16:17:25ZWinko W. AnSaketh SundarLisa YankowitzDaryush D. MehtaCarol L. Wilkinsonhttp://arxiv.org/abs/2605.28016v1Enhancing Ultra-low-field MRI with Segmentation-guided Adversarial Learning2026-05-27T06:11:34ZUltra-low-field (ULF) MRI offers portable and low-cost imaging but suffers from poor image quality. To address this, we present our submission to the 2025 ULF Enhancement Challenge (ULF-EnC), where the goal is to synthesise high-field-like MRIs from 64 mT scans. Our pipeline enhances ULF MRI through a combination of anatomical conditioning and model ensembling. We first generate tissue segmentation priors using a Swin UNETR trained solely on challenge-provided data. These priors condition two independent enhancement networks - a CycleGAN and a transformer-based residual enhancement model (T-REX) - each trained to synthesise 3 T-like MRIs. Outputs from both models are combined using a weighted average. Our approach produces enhanced MRIs that were comparable to high-field scans both quantitatively and qualitatively.2026-05-27T06:11:34ZJames GroverAndrew PhairMichael FerraroDavid E. J. Waddingtonhttp://arxiv.org/abs/2605.11637v2Computed Tomography Reconstruction Algorithm Using Markov Random Field Model2026-05-27T04:52:50ZX-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available.2026-05-12T06:58:44Z18 pages, 7 figuresTaiga ShimomiyaTaichi KusumiMasayuki UesugiAkihisa TakeuchiYuki SadaHayaru ShounoMasato Okada