https://arxiv.org/api/K8A/nauJaQ7nvb3ab3nog9N/bd82026-09-10T19:14:00Z92003015http://arxiv.org/abs/2608.30772v1Clustering based magnetic assays for SARS-CoV-2 detection with scFv-functionalized magnetic nanoparticles2026-08-31T13:35:00ZMagnetic nanoparticles (MNP) can be used in magnetic immunoassays (MIA) by functionalizing them with antibodies. In homogeneous assays that follow a "mix-and-measure" approach, it is then sufficient to add the sample in question and evaluate the response of the MNPs using a magnetic measurement method. Magnetic Particle Spectroscopy (MPS) is a fast and sensitive method for this purpose, capable of determining the binding state by measuring changes in Brownian relaxation. For further analysis, alternating current susceptometry (ACS) is considered, although it is significantly more time-consuming and therefore no option for applications interested in point of care detection. In this study, we aim to further improve the approach of MIA evaluated by MPS. To this end, we use self-synthesized scFv fragments instead of whole IgG antibodies during functionalization in order to keep the size of the BNF-Dextran MNP with 80 nm nominal diameter as small as possible, which allows for greater relative size changes upon binding to an analyte. Virus-like particles (VLP) and the N protein of SARS-CoV-2, which were also produced in-house, are used as analytes. Due to multiple binding sites, these form cluster structures, which, in the case of VLP, were investigated in greater depth ACS to assess their field dependence. In addition, the sensitivity of the assays was analyzed as a function of MNP concentration, and the detection limit for both analytes was estimated. We found that, using scFv-functionalized MNPs, we were able to detect low concentrations of just 490 fM of SARS-CoV-2 VLP and 1.7 nM of the N protein. However, the slightly above-proportional increase in sensitivity as the MNP concentration decreases does not automatically imply a better detection limit.2026-08-31T13:35:00ZF. T. WolgastN. LehmlerS. WesterhoffS. DemiralJ. LohmannR. AminR. SackA. LakM. SchillingM. SchubertT. Viereckhttp://arxiv.org/abs/2608.30430v1Imaging cellular-level brain microstructure with diffusion MRI2026-08-31T08:25:09ZNoninvasive live-cell imaging in deep human tissues is crucial for exploring the cellular biological and pathogenic processes, but remains a significant unmet challenge. Diffusion magnetic resonance imaging (dMRI) promises to narrow this gap by noninvasively providing cellular-level microstructural information. Within a single crowded voxel containing millions of living cells, the intricate cellular-level microstructures create numerous microcompartments, each characterized by a specific diffusivity. However, conventional dMRI methods relying on voxel-averaged macroscopic parameters, merely reflect aggregate microstructural properties and fail to quantify this distribution of microcompartment-specific diffusivity within a voxel, thereby obscuring microstructural details. Here, we propose an intravoxel diffusivity probability distribution (IDPD) model to resolve a wealth of essential microstructural information via quantifying microcompartment-specific diffusivity distribution, thereby enabling direct cellular-level characterization. This exceptional capability is realized through a multi-tiered analytical workflow spanning targeted single-voxel or region of interest (ROI) analysis to global visualization using dynamic videos and statistic parametric maps. Ultimately, the IDPD model enables noninvasive cellular-level microstructure imaging, offering a promising avenue to evaluate living cell functions in vivo.2026-08-31T08:25:09ZXiaodong LiJing ZhaoBaolan LuJinzhu WangXinhua WeiQingxian YangXuegang Xinhttp://arxiv.org/abs/2608.30411v1Spatially or temporally resolved phase-based optoretinography with actively-tracked point-scanning optical coherence tomography2026-08-31T08:08:11ZOptoretinography is a promising approach to measure visual function but its clinical translation has remained confined to research settings due to demanding hardware requirements. Here, we demonstrate that high-quality phase-based optoretinography can be performed using conventional point-scanning spectral-domain optical coherence tomography. We show that the need for high imaging speed can be circumvented by accurate sampling of phase changes at consistent spatial location. Light-evoked outer-segment expansion could be temporally resolved in B-scan series acquired at a fixed position when filtering off-location B-scans, and spatially resolved in volumes acquired at rates as low as 1~Hz. These results indicate that the technical barrier for phase-based optoretinography is substantially lower than previously assumed and pave the way toward broad clinical translation.2026-08-31T08:08:11ZLéo PuyoJonas FrankeFelix ZeisbergerRoland RocholzGereon Hüttmannhttp://arxiv.org/abs/2608.30100v1Unimodality and Radial Monotonicity of the Magnetic Resonance Fingerprinting T1/T2 Matching Objective2026-08-31T00:17:45ZMagnetic resonance fingerprinting (MRF) estimates tissue parameters by matching an acquired MR signal time course to entries in a Bloch- or EPG-simulated dictionary. However, no study has yet proven the uniqueness of the matching results. In two earlier studies by exhaustive objective mapping I showed that for two widely used MRF sequences the normalized-correlation objective exhibits a single dominant peak at the true T1/T2 values and decreases smoothly away from that peak. These empirical properties motivated the fast MRF-ZOOM search algorithm even without using a pre-generated signal dictionary, but their theoretical basis has remained incomplete. The purpose of this work is to develop a mathematical framework for the MRF matching objective under normalized-correlation matching.2026-08-31T00:17:45ZZe Wanghttp://arxiv.org/abs/2504.21193v2Slug-Mapper: Magnetic Scanner for Ultra Low-Field MRI Scanners2026-08-28T22:15:58ZUltra-Low Field (ULF) MRI scanners offer a portable and cost-effective alternative to conventional MRI systems, but require careful calibration to compensate for reduced magnetic field strength and signal quality. In this paper, we present Slug-Mapper, a low-cost, open-source magnetic field scanner designed to map the static field $B_0$ voxel-by-voxel within the bore of a ULF MRI system. Built using a repurposed 3D printer, a Raspberry Pi, and off-the-shelf components, Slug-Mapper enables high-resolution magnetic field characterization for both passive and active shimming. We provide a detailed overview of MRI physics, the engineering challenges of ULF systems, and the architecture and operation of Slug-Mapper. This tool bridges the gap between hardware prototyping and precise system calibration, supporting the development of accessible and portable MRI technology.2025-04-29T21:54:34ZJonathan W. Morrishttp://arxiv.org/abs/2608.28847v1A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging2026-08-28T20:35:03ZCompact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of $N_{cT}=1$, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~$μ$W, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for $N_{cT}=2$ and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.2026-08-28T20:35:03Z15 pages, 11 figures, JournalReza Pakdaman ZangabadXitie ZhangLevent DegertekinShaolan Lihttp://arxiv.org/abs/2507.23129v2MRpro: open framework for model-based, learned, and quantitative MR imaging2026-08-28T19:07:54ZWe preseent an open-source image reconstruction package built upon PyTorch, enabling modern deep-learning reconstructions. It uses open data formats for input and output (ISMRMRD, DICOM, NIfTI), allowing easy integration into existing pipelines and support for data from different devices. The framework comprises three main areas. First, it provides unified data structures for the consistent manipulation of MR datasets and their associated metadata (e.g., k-space trajectories). Second, it offers a library of composable operators, proximable functionals, and optimization algorithms, including a unified Fourier operator for all common trajectories and operators specifically developed for low-field applications, such as a B0-correction operator. These components are used to create ready-to-use implementations of key reconstruction algorithms. Third, for deep learning, MRpro includes essential building blocks such as data-consistency layers, differentiable optimization layers, state-of-the-art backbone networks, and access to public datasets to facilitate reproducibility. We demonstrate MRpro across automatic reconstruction, iterative SENSE, deep-learning-based reconstruction, and quantitative parameter estimation. Applications use public and simulated datasets and measured lowfield data acquired at 0.3 T, 0.6 T, and 47 mT.2025-07-30T22:15:24ZSubmitted to NMR in BiomedicineFelix Frederik ZimmermannPatrick SchuenkeChristoph S. AignerBill A. BernhardtMara GuastiniJohannes HammacherNoah JaitnerAndreas KoflerLeonid LuninStefan MartinCatarina Redshaw KranichJakob SchattenfrohDavid SchoteYanglei WuChristoph Kolbitschhttp://arxiv.org/abs/2608.28275v1Full-field fluorescence computed tomography (F3CT) using a calibrated virtual cone-beam pinhole geometry2026-08-28T12:37:25ZWe present F3CT, a synchrotron-based hyperspectral full-field fluorescence computed tomography technique that avoids raster scanning by combining a pinhole aperture with an energy-resolving 2D detector. A virtual cone-beam model and two-stage calibration-reconstruction workflow enable 3D elemental mapping under full-field illumination. The method is demonstrated on biological and geological specimens, resolving silver-stain distributions in zebrafish tissue and high-energy fluorescence signatures in rock cores. Phase-contrast tomograms acquired sequentially under the same experimental geometry provide co-registered structural context. F3CT provides a high-throughput route to 3D XRF imaging and establishes a foundation for correlated structural and chemical tomography, with potential for future in-situ and operando implementations.2026-08-28T12:37:25ZThomas ZillhardtYunhui ChenAlexander RackMatthew VealeMatt WilsonPhilip J. WithersNicola Viganòhttp://arxiv.org/abs/2608.27681v1Physics-Assisted Deep Learning Denoising for Stabilized IMPULSED dMRI Microenvironment Parameter Fitting2026-08-27T20:13:46ZDiffusion-weighted MRI (dMRI) is a powerful tool for quantifying cellular microenvironment parameters. This study proposes a physics-assisted deep learning (DL)-based denoising framework designed to enhance dMRI signal quality and improve the robustness of subsequent biophysical model fitting. A dataset of paired noise-free and Rician-noise-corrupted dMRI signals was generated using the IMPULSED-dMRI signal model. Three denoising architectures were evaluated: Convolutional Neural Networks (CNN), Multilayer Perceptron (MLP), and Long Short-Term Memory (LSTM) networks. Denoised signals were then fitted to estimate cell diameter $d$, intracellular volume fraction $V_{\mathrm{in}}$, and extracellular apparent diffusion coefficient $D_\mathrm{ex}$. DL-based processing substantially improved dMRI signal denoising. The MLP and LSTM achieved similar performance, with the LSTM slightly better overall, and both outperformed the CNN. In the subsequent model fitting step, the LSTM produced modest reductions in parameter MAE. The dominant benefit was fitting stabilization, with the overall fitting failure rate reduced from 57.6\% to 17.7\%. The proposed framework improves dMRI signal quality and stabilizes subsequent IMPULSED-based microenvironmental parameter fitting.2026-08-27T20:13:46Z26 pages, 6 figures, 1 tableWen LiYan DaiArely Perez RodriguezTodd AguileraJie DengXun Jiahttp://arxiv.org/abs/2608.27212v1Constrained estimation of rotational invariants of the cumulant expansion (RICE) for rapid tensor-valued diffusion MRI2026-08-27T14:55:55ZPurpose: To complement 1.5-minute measurements of common tensor-valued diffusion MRI (dMRI) markers with rapid constrained fitting.
Methods: Fast dMRI protocols for obtaining rotational invariants of the cumulant expansion (RICE) were paired with constrained weighted linear least squares (CWLLS) to stabilize the more fragile WLLS fit. A compact constraint set was formulated, including a novel mean-dependent upper bound on total diffusional variance. Evaluation used diffusion tensor distribution (DTD) simulations, healthy-volunteer data with a resolution-dependent SNR experiment, and a glioma patient dataset. A 5-minute q-space trajectory imaging (QTI) protocol served as a reference.
Results: Across experiments, CWLLS reduced unphysical estimates and fit outliers in parameters such as microscopic FA and isotropic diffusivity variance. In simulations, it narrowed error distributions most clearly in the CSF-dominant case, while some metrics showed a bias-variance trade-off. In vivo, CWLLS removed negative variance estimates, truncated out-of-bounds tails, and reduced artifacts in fluid-contaminated voxels while preserving anatomical contrast. It also retained more stable maps than WLLS at higher resolution, although both estimators degraded in the lowest-SNR setting. Notably, the new mean-dependent variance bound was violated in 15.4% of voxels in the patient dataset, accounting for nearly half of the 32.7% that violated at least one constraint. Healthy-volunteer benchmarking showed that CWLLS completed in under 30 seconds. The constrained QTI fit required 72 minutes, making CWLLS 160 times faster.
Conclusion: CWLLS for fast RICE yielded high-quality parameter maps at an online-ready computational cost. This may enhance the reliability of dMRI tissue characterization and strengthen the path toward clinical translation.2026-08-27T14:55:55Z11 pages, 5 figures. Jinyang Yu and Oliver Gödicke contributed equally to this work. Submitted to Magnetic Resonance in MedicineJinyang YuOliver GödickeFrederik B. LaunObada T. AlhalabiIris A. KohlerJürgen HesserSandro M. KriegBogdana SuchorskaHeinz-Peter SchlemmerMark E. LaddDavid BonekampJohann M. E. JendeTristan A. Kuderhttp://arxiv.org/abs/2608.26901v1Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning2026-08-27T10:05:01ZAutomating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ($D_{95}$), though statistical analysis revealed a marginal reduction in target homogeneity ($p<0.001$) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ($p<0.001$). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in $11$ out of $14$ Moderate Hypofraction Arm plans and $9$ out of $12$ Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.2026-08-27T10:05:01ZThe paper consists of 22 pages, 4 figures, 6 tables. The end-to-end pipeline of Dose-PlanNet will soon be made available on the GitHub repository of CHAVI-India (https://github.com/CHAVI-India)Ankit BhattacharjeeSougata MaitySantam ChakrabortyIndranil Mallickhttp://arxiv.org/abs/2601.05063v2Quantitative mapping from conventional MRI using self-supervised physics-guided deep learning: applications to a large-scale, clinically heterogeneous dataset2026-08-27T09:52:31ZMagnetic resonance imaging (MRI) is a cornerstone of clinical neuroimaging, yet conventional MRIs provide qualitative information heavily dependent on scanner hardware and acquisition settings. While quantitative MRI (qMRI) offers intrinsic tissue parameters, the requirement for specialized acquisition protocols and reconstruction algorithms restricts its availability and impedes large-scale biomarker research. This study presents a self-supervised physics-guided deep learning framework to infer quantitative T1, T2, and proton-density (PD) maps directly from widely available clinical conventional T1-weighted, T2-weighted, and FLAIR MRIs. The framework was trained and evaluated on a large-scale, clinically heterogeneous dataset comprising 4,121 scan sessions acquired at our institution over six years on four different 3 T MRI scanner systems, capturing real-world clinical variability. The framework integrates Bloch-based signal models directly into the training objective. Across more than 600 test sessions, the generated maps exhibited white matter and gray matter values consistent with literature ranges. Additionally, the generated maps showed invariance to scanner hardware and acquisition protocol groups, with inter-group coefficients of variation $\leq$ 1.1%. Subject-specific analyses demonstrated excellent voxel-wise reproducibility across scanner systems and sequence parameters, with Pearson $r$ and concordance correlation coefficients exceeding 0.82 for T1 and T2. Mean relative voxel-wise differences were low across all quantitative parameters, especially for T2 ($<$ 6%). These results indicate that the proposed framework can robustly transform diverse clinical conventional MRI data into quantitative maps, potentially paving the way for large-scale quantitative biomarker research.2026-01-08T16:08:58Z36 pages, 17 figures, full paperJelmer van LuneStefano MandijaOscar van der HeideMatteo MasperoMartin B. SchilderJan Willem DankbaarCornelis A. T. van den BergAlessandro Sbrizzihttp://arxiv.org/abs/2608.26891v1Sparse Delta Integration method for the calculation of spatiotemporal pressure fields of arbitrary ultrasound transducer geometries2026-08-27T09:46:32ZAccurate and efficient simulation of ultrasound pressure fields and pulse-echo responses is essential for transducer design, beamforming optimization, and model-based imaging research. Conventional Spatial Impulse Response methods compute acoustic fields by explicitly sampling trapezoidal impulse responses for each rectangular aperture subdivision, which leads to high computational cost for large apertures, dense spatial grids, and high sampling frequencies. We introduce Sparse Delta Integration, a mathematical framework for the far-field SIR of rectangular apertures that expresses the trapezoidal spatial impulse response as the double integration of a sparse set of Dirac delta distributions. This formulation yields compact expressions for time-domain and frequency-domain SIRs and enables vectorized implementations whose computational cost is independent of the trapezoid duration. We further derive a spectral formulation for pulse-echo simulation that removes part of the conventional Fourier-domain convolution pipeline. Implemented in the open-source Python package eSDIva, these methods achieve speedups of up to 180x for temporal SIR computation and up to 20x for pulse-echo RF simulation relative to Field II, while maintaining high numerical accuracy with mean squared errors below 1e-5 and correlation coefficients close to unity.2026-08-27T09:46:32ZDeyver E. RiveraCharlie DemeneMickael Tanterhttp://arxiv.org/abs/2608.26330v1Adapting the TG-43 formalism for use in Diffusing alpha-emitters Radiation Therapy2026-08-26T19:11:31ZBackground: Diffusing alpha-emitters Radiation Therapy ("Alpha DaRT") enables the treatment of solid tumors using alpha particles. In Alpha DaRT, the tumor dose distribution is mainly dictated by the diffusion of the decay products of $^{224}$Ra. Due to the inherently different mechanism of dose delivery of the Alpha-DaRT source compared to sources emitting only electrons or photons, the conventional formalism of TG-43 cannot be directly applied to Alpha DaRT. Purpose: To adapt the TG-43 formalism to be used with the Alpha-DaRT model, with the specific aim of allowing commercial treatment-planning software packages to be used for Alpha-DaRT treatment planning. Methods: The effective dose rate is defined, along with an activity conversion factor. These, together with a numerical calculation that solves the model equations, allow implementing the Alpha-DaRT model predictions into the TG-43 formalism. Results: An example of calculated $F(r, θ)$ and $g_L(r)$ tables is presented for an Alpha-DaRT treatment scenario, with the model parameters representing preclinical data on squamous cell carcinoma. Conclusions: Commercial software can be used for Alpha-DaRT treatment planning. However, the generated $F(r, θ)$ and $g_L(r)$ tables depend on tissue parameters, as well as treatment duration, and so these tables should be generated on a case-by-case basis.2026-08-26T19:11:31ZGuy HegerLior EpsteinLior Arazihttp://arxiv.org/abs/2608.12200v2A 2D Hydrothermodynamic Analytical Model for Rapid Tumor Ablation using High-Intensity Focused Ultrasound2026-08-26T13:15:13ZWe establish a self-consistent 2D hydrothermodynamic analytical model for high-intensity focused ultrasound tumor ablation. Expanding compressible Navier-Stokes equations to second order demonstrates that a stationary cellular matrix suppresses acoustic streaming ($\mathbf{v}_2 = 0$). This constraint forces the absorbed wave momentum flux to convert entirely into localized, time-averaged static pressure gradients ($\nabla \langle p_2 \rangle = \mathbf{F}_2$), bridging non-linear hydrodynamics with thermodynamic dissipation. Solving the non-diffusive Pennes bioheat equation under a $1.0\,\text{s}$ top-hat pulse reveals that a spherically focusing geometry ($\propto 1/r^2$) overrides exponential damping past a critical geometric threshold ($r_{\text{crit}} = 2x_0$), preventing upstream skin overheating. We derive an optimization criterion where the absorption coefficient matches half the inverse target depth ($α= 1/2x_0$). Solving the non-isothermal Arrhenius integral yields a sharp lesion boundary radius at $r_b = 0.75\,w_0$, where the volume average reaches $72.1^\circ\text{C}$ while the core peaks at $90.0^\circ\text{C}$. Post-pulse 2D free-space Green's function convolution confirms immediate monotonic thermal decay ($\partial θ/\partial t' < 0$) outside this boundary. This closed-form framework provides explicit scaling laws for non-invasive wave-matter thermal confinement, bypassing computationally heavy numerical simulations.2026-08-12T15:54:20Zsubmitted for publication, typos corrected, improvements madeD. Tsiklauri