https://arxiv.org/api/wpFpY9PCXM56m0pTTeWq7k/fSCg2026-06-21T23:10:37Z898527015http://arxiv.org/abs/2602.11873v2Time-resolved aortic 3D shape reconstruction from a limited number of cine 2D MRI slices2026-03-31T14:44:35ZBackground and Objective: To assess the feasibility and accuracy of reconstructing time-resolved, three-dimensional, subject-specific aortic geometries from a limited number of standard cine 2D magnetic resonance imaging (MRI) acquisitions. This is achieved by coupling a statistical shape model with a differentiable volumetric mesh optimization algorithm.
Methods: Cine 2D MRI slices were manually segmented and used to reconstruct subject-specific aortic geometries via a differentiable mesh optimization algorithm, constrained by a statistical shape model. Optimal slice positioning was first evaluated on synthetic data, followed by in-vivo acquisition in 30 subjects (19 volunteers and 11 aortic stenosis patients). Time-resolved aortic geometries were reconstructed, from which geometric descriptors and radial strain were derived. In a subset of 10 subjects, 4D flow MRI data was acquired to provide volumetric reference for peak-systolic shape comparison.
Results: Accurate reconstruction was achieved using as few as six cine 2D MRI slices. Agreement with 4D flow MRI reference data yielded a Dice score of (89.9 +/- 1.6) %, Intersection over Union of (81.7 +/- 2.7) %, Hausdorff distance of (7.3 +/- 3.3) mm, and Chamfer distance of (3.7 +/- 0.6) mm. The mean absolute radius error along the aortic arch was (0.8 +/- 0.6) mm. Secondary analysis demonstrated significant differences in geometric features and radial strain across age groups, with strain decreasing progressively with age at values of (11.00 +/- 3.11) x 10-2 vs. (3.74 +/- 1.25) x 10-2 vs. (2.89 +/- 0.87) x 10-2 for the young, mid-age, and elderly groups, respectively.
Conclusion: The proposed framework enables reconstruction of time-resolved, subject-specific aortic geometries from a limited number of standard cine 2D MRI acquisitions, providing a practical basis for downstream computational analysis.2026-02-12T12:23:41ZGloria WolkerstorferStefano BuosoRabea SchlenkerJochen von SpiczakRobert MankaSebastian Kozerkehttp://arxiv.org/abs/2603.29671v1Gaussian sample model in in-line imaging2026-03-31T12:28:35ZWe investigate the gain in Shannon information that can be extracted from an X-ray image obtained after coherent free-space propagation of the transmitted beam and subsequent digital processing of the detected image. We show that simulated digital forward free-space propagation can produce a much higher formal information gain, both in projection imaging and in phase-contrast computed tomography, compared to conventional phase retrieval based on the Transport of Intensity equation. However, it appears that the extra information gained in the simulated free-space propagation may be due in part to superficial high-frequency content in the obtained images, rather than due to a genuine improvement of the spatial resolution. This points to the need to critically evaluate the performance of different types of image quality metrics and their relationship to the information content of the images.2026-03-31T12:28:35Z18 pages, 2 tablesTimur E. GureyevDavid M. PaganinHarry M. Quineyhttp://arxiv.org/abs/2603.29408v1Using Fast Reading Current Integrator for Advanced Ion Beam Diagnostics Across Continuous and Pulsed Modes2026-03-31T08:12:55ZA fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid digitization architecture based on charge-balancing and voltage-to-frequency conversion. The input current is converted into a pulse stream corresponding to discrete charge quanta, enabling event-driven measurement with temporal resolution down to 0.5 ms while preserving a wide dynamic range and high linearity. The system further enables real-time pulse selection for instantaneous dose-rate estimation and reconstruction of time-dependent beam structures. A deterministic beam-interrupt signal is generated within <1 us upon reaching a predefined charge threshold, enabling fast feedback control. Additional functionalities, including threshold- and slope-based gating as well as phase-sensitive detection, enhance performance under noisy or modulated beam conditions. Calibration with precision current sources and beamline detectors demonstrates stable operation with excellent linearity and timing fidelity. The proposed system provides a compact and flexible platform for next-generation ion beam diagnostics requiring fast response, large dynamic range, and time-resolved measurement.2026-03-31T08:12:55Z10 figuresI-Chun ChoChien-Hsu ChenHuan NiuCheng-Ya PanChun-Hui HsingTung-Yuan Hsiaohttp://arxiv.org/abs/2603.27907v1Localization-driven exchange contrast in diffusion exchange spectroscopy2026-03-29T23:30:03ZDiffusion exchange spectroscopy (DEXSY) is a method to probe exchange between domains of varying confinement. Analyses of DEXSY signals typically assume Gaussian diffusion within distinct compartments and first-order exchange kinetics between them. Other situations can yield DEXSY signal contrast with respect to mixing time, however, leading to potentially erroneous interpretation. Here, we demonstrate that a one-dimensional compartment with reflecting boundaries and without relaxation can by itself produce such contrast in certain experimental regimes. The origin of this contrast is the diffusive mixing of spin isochromats initially near versus far from either boundary, as the former can be relatively coherent in an effect known as edge enhancement or signal localization. We consider DEXSY signals in the case of extended field gradients and identical encodings. Signals were generated via a numerical approach that solves the Bloch-Torrey equation in discrete space and time using matrix operators. We find that in the localization regime, an apparent first-order rate constant of exchange, $k$, can be extracted from DEXSY signals even in this minimal system. The measured $k$ is approximately proportional to $D/L^2$, where $D$ is the diffusivity and $L$ is the domain size. Typically, $k \approx π^2 D/L^2$. We attribute this localization-driven exchange to the relaxation of spatial magnetization modes with mixing time, noting that $π^2 D/L^2$ is the first non-zero eigenvalue of the Laplacian basis. These results demonstrate that DEXSY and related methods such as filter exchange spectroscopy (FEXSY) may not be specific to genuine barrier permeation.2026-03-29T23:30:03Z14 pages, 7 figuresTeddy X CaiNathan H WilliamsonPeter J Basserhttp://arxiv.org/abs/2603.27322v1Deep brain microelectrode signal: $q$-statistical approach2026-03-28T16:01:04ZWe characterize the amplitude statistics of intraoperative microelectrode recordings (MERs) obtained during deep brain stimulation (DBS) surgery in 46 patients with Parkinson's disease, using 184 recordings equally balanced between inside and outside the subthalamic nucleus (STN). The probability density of every recording is quantitatively well described by a $q$-Gaussian (grounded on a nonadditive entropic functional), $ρ(x) \propto [1 + β(q-1) x^2]^{-1/(q-1)}$, with $q > 1$ in all cases, reflecting persistent long-range temporal correlations inconsistent with Gaussian dynamics. Within the superstatistics framework, the slowly fluctuating local variance visible in the raw MER signals is a physical mechanism that directly generates the $q > 1$ form. Beyond individual fits, $q$ and $β$ collapse across all 184 recordings onto the single functional constraint $q = 3 - 1.85\,β^{-0.33}$ ($R \approx -0.91$), a reduction to one effective degree of freedom that is the quantitative hallmark of near-critical dynamics, previously identified in scale-free network growth and in acoustic precursors of material fracture. The index $q$ is statistically indistinguishable across the STN boundary ($\langle\bar{q}_\text{out}/\bar{q}_\text{in} \rangle = 1.03$), while the inverse-widthparameter shows a modest systematic difference ($\langle\barβ_\text{out}/\barβ_\text{in} \rangle = 1.18$). Since $q > 1$ is expected for any brain structure exhibiting long-range correlations, healthy or pathological, it is the tight $q(β)$ coupling, not $q > 1$ per se, that constitutes the candidate near-criticality signature of the parkinsonian cortico-basal-ganglia-thalamocortical loop.2026-03-28T16:01:04Z13 pages and 4 figuresAna Luiza Souza TavaresHenrique Santos LimaArtur Pedro Martins NetoBruno Duarte GomesConstantino Tsallishttp://arxiv.org/abs/2507.14963v2STEPC: A Multi-energy Nonuniform Response Calibration Framework for Photon-Counting Micro-CT in Multi-material Imaging2026-03-28T15:18:16ZPhoton-counting computed tomography has demonstrated significant advancements in recent years; however, micro photon-counting CT (Micro-PCCT) systems are still limited by pixel-wise detector response nonuniformity, which degrades measurement uniformity across detector pixels and commonly produces ring artifacts in reconstructed images. Existing calibration methods exhibit limited generalizability in complex multi-material scenarios, such as contrast-enhanced imaging. This study introduces a Signal-to-Nonuniformity Error Polynomial Calibration (STEPC) framework based on measurement nonuniformity error modeling to address this issue. STEPC first fits multi-energy projections using a 2D polynomial surface to generate ideal references, then applies a nonlinear multi-energy polynomial model to predict and correct pixel-wise nonuniformity errors. The model is calibrated using homogeneous slab phantoms of different materials, including PMMA, aluminum, and iodinated contrast agents, enabling correction for both non-contrast and contrast-enhanced imaging. Experiments were performed on a custom Micro-PCCT system with phantoms and mouse. Correction performance of STEPC was evaluated using the mean local standard deviation (MLSD) in the projection domain and the ring artifact deviation (RAD) on the reconstructed images. Compared with existing methods, STEPC achieved an average MLSD reduction of at least 21.58% and reduced RAD by at least 14.18%, consistently yielding the best performance in both non-contrast and contrast-enhanced scenarios. Furthermore, STEPC can be readily extended to compensate for beam hardening effects within the same calibration framework. Quantitative material decomposition results indicate that the proposed method preserves measurement accuracy across different basis materials...2025-07-20T13:50:55Z16 pages, 15 figures. accepted by TIMIEEE Transactions on Instrumentation and Measurement, Early Access, 2026Enze ZhouWenjian LiWenting XuYuwei LuShangbin ChenShaoyang WangGang ZhengTianwu XieQian Liu10.1109/TIM.2026.3677968http://arxiv.org/abs/2603.27124v1Extending Regression Without Truth to Integrate Ground-Truth Measurements for Evaluating Quantitative Imaging Methods with Patient Data2026-03-28T04:30:14ZObjective evaluation of quantitative imaging (QI) methods with patient data is often hindered by the lack of gold standards. To address this challenge, a class of regression-without-truth (RWT) techniques have been developed. These techniques assume that the true and measured values are linearly related and estimate the linear-relationship parameters without access to true values. However, reliable estimation of these parameters typically requires many patient samples, which can be expensive and time consuming to obtain, and even impossible in settings such as studies with rare diseases or with new clinical imaging procedures. Thus, there is an important need for strategies to perform evaluation of quantitative imaging methods with a small number of patient samples. In this context, we note that datasets with known ground truth, such as physical phantom studies, could be available. In this manuscript, we propose an approach that integrates information from both patient data without ground truth and known-ground-truth datasets to perform objective evaluation of QI methods. We validated the proposed approach using numerical studies, which showed that the proposed approach yielded improved performance in ranking QI methods compared with RWT technique. The results demonstrate the potential of the proposed approach for evaluating QI methods when patient data are limited and motivate further validation with clinically realistic simulation studies and clinical data.2026-03-28T04:30:14ZYan LiuAbhinav K. Jhahttp://arxiv.org/abs/2603.27122v1Comparing evaluation of quantitative imaging methods using reference standards vs. regression-without-truth-based technique2026-03-28T04:26:03ZClinical translation of quantitative imaging (QI) methods requires objective evaluation of these methods on reliably measuring the underlying true quantitative values. Ideally, such evaluation would be performed using ground truth or gold standards. However, in clinical practice, ground truth is generally unavailable, and obtaining gold standards for large patient cohorts is often impractical or infeasible. In these scenarios, evaluation using well-accepted or commonly used methods for measuring the quantitative values that may have bias and/or measurement error, referred to as reference standards, is a common alternative. However, the error in reference standards might lead to inaccurate results in evaluating the QI methods. To address the challenge of evaluation without a gold standard, a class of regression-without-truth (RWT)-based techniques has also been proposed. These techniques compare QI methods without requiring ground truth and have demonstrated promise across multiple applications. This raises an important question: how does evaluation using reference standards vs. RWT-based techniques compare? Our work, which investigates this question using controlled numerical experiments, showed that when the measurement error of the reference standard exceeded a certain level, evaluation with a RWT-based technique outperformed evaluation with reference standards. This study provides insights for selecting appropriate evaluation strategies when gold standards are unavailable and motivates further investigation in clinically realistic settings.2026-03-28T04:26:03ZYan LiuAbhinav K. Jhahttp://arxiv.org/abs/2603.04955v2Uncertainty quantification in neural network-based glucose prediction for diabetes2026-03-28T01:27:55ZIn this work, we investigate uncertainty-aware neural network models for blood glucose prediction and adverse glycemic event identification in Type 1 diabetes. We consider three families of sequence models based on LSTM, GRU, and Transformer architectures, with uncertainty quantification enabled by either Monte Carlo dropout or through evidential output layers compatible with Deep Evidential Regression. Using the HUPA-UCM diabetes dataset for validation, we find that Transformer-based models equipped with evidential output heads provide the most effective uncertainty-aware framework, achieving consistently higher predictive accuracies and better-calibrated uncertainty estimates whose magnitudes significantly correlate with prediction errors. We further evaluate the clinical risk of each model using the recently proposed Diabetes Technology Society error grid, with risk categories defined by international expert consensus. Our results demonstrate the value of integrating principled uncertainty quantification into real-time machine-learning-based blood glucose prediction systems.2026-03-05T08:49:43Z20 pages, 7 figures; v2: minor revisions with PR-AUC curves included in result analysis. Code available at https://github.com/HaiSiong-Tan/Uncertainty_aware_glucose_predictionHai Siong TanRafe McBethhttp://arxiv.org/abs/2603.27003v1AI-enabled cardiac shape reconstruction from routine magnetic resonance imaging2026-03-27T21:26:20ZComputational models of cardiac structure and function are increasingly central to the development of subject-specific cardiac digital twins, enabling improved characterization of contractile dysfunction, pathological remodeling, and electrical abnormalities. A critical prerequisite for these models is the accurate reconstruction of three-dimensional (3D) cardiac anatomy from medical imaging. Multi-planar magnetic resonance imaging, particularly when combined with artificial intelligence, offers a clinically feasible alternative to conventional reconstruction techniques. In this study, we present a neural field-based reconstruction framework that recovers 3D cardiac geometries from sparse planar contour data by learning continuous shape representations. Reconstruction performance was evaluated using complementary in-silico and in vivo datasets spanning variations in sampling density and geometric complexity. Across both datasets, reconstructed meshes closely matched reference geometries, demonstrating that the neural field approach faithfully captures cardiac planar contours. Compared with traditional local interpolation methods, the proposed framework exhibited improved geometric fidelity in anatomically challenging regions, including the left ventricular apex and basal segments, particularly under sparse sampling conditions. Collectively, these findings demonstrate that neural field-based reconstruction provides a robust and efficient pathway for multi-planar cardiac shape recovery, with particular relevance for AI-driven modeling pipelines and data-limited settings such as small-animal and time-resolved cardiac imaging.2026-03-27T21:26:20ZTanmay MukherjeeNeil GautamNikhil KadivarElizabeth M. FugateKyle J. MyersDiana LindquistPierre CroisilleSakthivel SadayappanPatrick ClarysseJacques OhayonRoderic PettigrewGeorge KarniadakisReza Avazmohammadihttp://arxiv.org/abs/2603.26911v1Hemodynamic Performance and Blood Damage of the Intra-Aortic Pumps: A CFD-Based Investigation2026-03-27T18:39:14ZThree intra-aortic blood pumps were evaluated and compared using CFD simulations. The aim of this study is to evaluate the hemodynamic performance and calculate the hemolytic potential of the pumps. The flow fields generated by the pumps were simulated using CFD with a wall-modeled large eddy simulation (WMLES) approach. The simulations produced pressure-flow curves, hydraulic efficiency, shear stress distributions, and hemolysis predictions. A grid study was conducted using the Grid Convergence Index (GCI) method, and a new dimensionless parameter, the Hemolytic Number (HN), was introduced as a standardized metric to compare hemolysis and universal pump performance. The impeller-driven pump had the highest-pressure head (~800 Pa at 4 L/min) and the best hydraulic efficiency (~6% at 14 L/min), outperforming both the single (maximum 2.7%) and triplet (maximum 2.2%) pumps. The NIH values were also lowest for the impeller pump (NIH = 0.0035 g/100L), indicating high hemocompatibility. Both the single and triplet pumps showed regions of recirculation, particularly at lower flow rates. A smaller HN indicates better hemocompatibility; for the impeller-driven pump, HN remains below 1 across the investigated flow rates. Overall, the impeller-driven pump outperformed the other designs in terms of both hemodynamic and hemolytic measurements. The findings provide valuable insights for the future development of intra-aortic pumps and the personalized selection of devices for individual patients.2026-03-27T18:39:14Z24 pages, 1 table, 9 figures. It has been published as an original article. Med Biol Eng Comput (2026)Osman AycanYeojin ParkLyes Kadem10.1007/s11517-026-03550-yhttp://arxiv.org/abs/2512.02748v2BART Streams: Real-time Reconstruction Using a Modular Framework for Pipeline Processing2026-03-27T17:13:33ZPurpose: To create modular solutions for interactive real-time MRI using reconstruction algorithms implemented in BART.
Methods: A new protocol for streaming of multidimensional arrays is presented and integrated into BART. The new functionality is demonstrated using examples for cardiac interactive real-time MRI based on radial FLASH, where iterative reconstruction is combined with advanced features such as dynamic coil compression and gradient-delay orrection. We analyze the latency of the reconstruction and measure end-to-end latency of the full imaging process.
Results: Reconstruction pipelines with iterative reconstruction and advanced functionality were built in a modular way using scripting. Latency measurements demonstrate latency sufficient for interactive real-time MRI, on the order of 30 ms for BART processing and network transfer time, or 200 ms for end-to-end latency including acquisition, vendor processing, and display.
Conclusion: With the new streaming capabilities, real-time reconstruction pipelines can be assembled using BART in a flexible way, enabling rapid prototyping of advanced applications such as interactive real-time MRI.2025-12-02T13:31:28ZSubmitted to Magnetic Resonance in MedicinePhilip SchatenMoritz BlumenthalBernhard RappChristina Unterberg-BuchwaldMartin Uecker10.1002/mrm.70455http://arxiv.org/abs/2511.22566v2PET Rapid Image Reconstruction Challenge (PETRIC)2026-03-27T16:44:02ZIntroduction: We describe the foundation of PETRIC, an image reconstruction challenge to minimise the computational runtime of related algorithms for Positron Emission Tomography (PET).
Purpose: Although several similar challenges are well-established in the field of medical imaging, there have been no prior challenges for PET image reconstruction.
Methods: Participants are provided with open-source software for implementation of their reconstruction algorithm(s). We define the objective function and reconstruct "gold standard" reference images, and provide metrics for quantifying algorithmic performance. We also received and curated phantom datasets (acquired with different scanners, radionuclides, and phantom types), which we further split into training and evaluation datasets. The automated computational framework of the challenge is released as open-source software.
Results: Four teams with nine algorithms in total participated in the challenge. Their contributions made use of various tools from optimisation theory including preconditioning, stochastic gradients, and artificial intelligence. While most of the submitted approaches appear very similar in nature, their specific implementation lead to a range of algorithmic performance.
Conclusion: As the first challenge for PET image reconstruction, PETRIC's solid foundations allow researchers to reuse its framework for evaluating new and existing image reconstruction methods on new or existing datasets. Variant versions of the challenge have and will continue to be launched in the future.2025-11-27T15:59:06ZFront. Nucl. Med. 2026. 6:1770002.Casper da Costa-LuisMatthias J. EhrhardtChristoph KolbitschEvgueni OvtchinnikovEdoardo PascaKris ThielemansCharalampos Tsoumpas10.3389/fnume.2026.1770002http://arxiv.org/abs/2603.26558v1Fluid dynamics informed CCTA-derived geometric parameters in right coronary artery anomalies predict abnormal invasive Adenosine FFR and Dobutamine FFR2026-03-27T16:19:18ZBackground: Right anomalous aortic origin of coronary arteries (R-AAOCA) involves fixed compression, assessable with adenosine-derived fractional flow reserve (FFRAdnosine), and additional stress-induced dynamic compression captured by dobutamine-derived FFR (FFRDobutamine). We hypothesized that coronary CT angiography (CCTA)-derived fluid dynamics-informed parameters outperform conventional metrics in predicting both FFR types. Methods: We retrospectively analyzed CCTA data from R-AAOCA patients who underwent invasive FFRAdnosine and FFRDobutamine assessment. Parameters were categorized as: (1) conventional metrics (cross-sectional area, perimeter, minor/major axis, intramural lumen area [ILA], effective diameter, area and diameter stenosis ratios) and (2) fluid dynamics-informed metrics (hydraulic diameter, elliptic ratio, circularity, hydraulic diameter stenosis ratio, resistance index [RI], ostial angulation penalty [OAP], and comprehensive stenosis score [CSS]). Hemodynamic relevance was defined as FFR$\leq$0.80. Results: 81 patients were included. FFRAdnosine$\leq$0.80 occurred in 5 (6.2%) and FFRDobutamine$\leq$0.80 in 16 (19.8%) patients. For FFRAdnosine, top discriminators were RI (AUC=0.97), OAP (AUC=0.97), ostial area (AUC=0.96), and CSS (AUC=0.95). For FFRDobutamine, ostial minor diameter led (AUC=0.85), followed by RI (AUC=0.83) and ILA minor diameter (AUC=0.81). RI explained 45% and 43% of FFRAdnosine and FFRDobutamine variance, respectively. At optimal thresholds, RI achieved 100% sensitivity and 95% specificity for FFRAdnosine; ostial minor diameter achieved 100% sensitivity and 57% specificity for FFRDobutamine. Conclusions: In R-AAOCA, CCTA-derived fluid dynamics-informed metrics provide excellent and superior performance compared with conventional geometric parameters in predicting hemodynamic relevance of fixed compression.2026-03-27T16:19:18Z5 figures, and 5 TablesAli MokhtariAnselm W. StarkDominik ObristMarius R. BiglerStefano F de MarchiLorenz RaberIsaac ShiriChristoph Graenihttp://arxiv.org/abs/2509.01752v2Clinical Metadata Guided Limited-Angle CT Image Reconstruction2026-03-27T12:47:18ZLimited-angle computed tomography (LACT) offers improved temporal resolution and reduced radiation dose for cardiac imaging, but suffers from severe artifacts due to truncated projections. To address the ill-posedness of LACT reconstruction, we propose a two-stage diffusion framework guided by structured clinical metadata. In the first stage, a transformer-based diffusion model conditioned exclusively on metadata, including acquisition parameters, patient demographics, and diagnostic impressions, generates coarse anatomical priors from noise. The second stage further refines the images by integrating both the coarse prior and metadata to produce high-fidelity results. Physics-based data consistency is enforced at each sampling step in both stages using an Alternating Direction Method of Multipliers module, ensuring alignment with the measured projections. Extensive experiments on both synthetic and real cardiac CT datasets demonstrate that incorporating metadata significantly improves reconstruction fidelity, particularly under severe angular truncation. Compared to existing metadata-free baselines, our method achieves superior performance in SSIM, PSNR, nMI, and PCC. Ablation studies confirm that different types of metadata contribute complementary benefits, particularly diagnostic and demographic priors under limited-angle conditions. These findings highlight the dual role of clinical metadata in improving both reconstruction quality and efficiency, supporting their integration into future metadata-guided medical imaging frameworks.2025-09-01T20:14:15ZIEEE Transactions on Medical Imaging, 2026Yu ShiShuyi FanChangsheng FangShuo HanHaodong LiLi ZhouBahareh MorovatiDayang WangHengyong Yu10.1109/TMI.2026.3677586