https://arxiv.org/api/QlSoo4f7ZOhPaYo2y9T4Wri4cTU2026-06-21T20:55:37Z898524015http://arxiv.org/abs/2604.16455v1Drug-delivery Ca-Mg silicate scaffolds encapsulated in PLGA2026-04-07T22:26:29ZThe aim of this work is to develop dual-functional scaffolds for bone tissue regeneration and local antibiotic delivery applications. In this respect, bioresorbable bredigite (Ca7MgSi4O16) porous scaffolds were fabricated by a foam replica method, loaded with vancomycin hydrochloride and encapsulated in poly lactic-co-glycolic acid (PLGA) coatings. Field emission scanning electron microscopy, Archimedes porosimetry and Fourier-transform infrared spectroscopy were used to characterize the structure of the scaffolds. The drug delivery kinetics and cytocompatibility of the prepared scaffolds were also studied in vitro. The bare sample exhibited a burst release of vancomycin and low biocompatibility with respect to dental pulp stem cells based on the MTT assay due to the fast bioresorption of bredigite. While keeping the desirable characteristics of pores for tissue engineering, the biodegradable PLGA coatings modified the drug release kinetics, buffered physiological pH and hence improved the cell viability of the vancomycin-loaded scaffolds considerably.2026-04-07T22:26:29ZInternational Journal of Pharmaceutics, 589 (2020) 119855A. JadidiE. SalahinejadE. SharifiL. Tayebi10.1016/j.ijpharm.2020.119855http://arxiv.org/abs/2604.16454v1Competition of carrier bioresorption and drug release kinetics of vancomycin-loaded silicate macroporous microspheres to determine cell biocompatibility2026-04-07T22:22:26ZBioceramic porous microspheres are promising substances for dental and orthopedic bone void filling, tissue engineering and drug delivery applications. In this research, the structure and cytocompatibility of bioactive magnesium-calcium silicate macroporous microspheres loaded with vancomycin hydrochloride, an antibiotic drug, were studied. In this regard, bredigite (Ca7MgSi4O16), akermanite (Ca2MgSi2O7) and diopside (CaMgSi2O6) carriers were fabricated through a sequence of sol-gel, calcination, droplet extrusion and sintering processes, followed by impregnated with vancomycin. X-ray diffraction (XRD) and scanning electron microscopy verified the formation of the desired ceramic crystalline phases and macroporous characteristics of the carriers, respectively. Based on the MTT assay, the antibiotic-loaded bredigite, akermanite and diopside devices comparatively exhibited the lowest, intermediate and highest levels of human bone marrow mesenchymal stem cells (hBM-MSCs) viability and proliferation, respectively. It was concluded that the role of the carrier bioresorption kinetics prevails over the drug delivery kinetics in determining the cell biocompatibility of the devices.2026-04-07T22:22:26ZCeramics International, 46 (2020) 26156-26159A. Bolandparvaz JahromiE. Salahinejad10.1016/j.ceramint.2020.07.112http://arxiv.org/abs/2604.06500v1Maximum Likelihood Estimation Yields Accurate Line-of-Response Assignment for Positron + Prompt Gamma Ray Events in Multiplexed PET (mPET)2026-04-07T22:11:27ZFor accurate disease characterization using positron emission tomography (PET), it is desirable to image multiple radiotracers in a single scan. Conventional PET methods cannot do this due to the indistinguishable annihilation photons produced by different radiotracers. One approach is to label one radiotracer with a positron+prompt-gamma ($β^+\!\!-\!\!γ$) isotope producing triple coincidences, and another with a pure positron-emitting ($β^+$) isotope producing double coincidences. However, $β^+\!\!-\!\!γ$ emitters present challenges in correctly identifying the two annihilation photons, or equivalently, assigning the correct line-of-response (LOR) to triple-photon coincidence events. Here, we propose a maximum likelihood estimation (MLE) framework leveraging spatial, timing, and energy information to determine the most probable LOR. Simulation studies validated the method: simulations showed over 96\% and 94\% accuracy for LOR assignment of $β^+\!\!-\!\!γ$ emitters $^{22}$Na and $^{124}$I point sources, respectively. Furthermore, simulated phantom imaging of $^{22}$Na or $^{124}$I distributions alongside a $β^+$ emitter demonstrated that MLE LOR assignment achieved comparable image quality -- measured by contrast recovery coefficient (CRC) and cross-talk ratio (XR) -- to benchmark methods, where the prompt gamma was identified using an energy threshold ($\geq 650$ keV) for $^{22}$Na and as the highest-energy photon for $^{124}$I.2026-04-07T22:11:27Z12 pages, 7 figures, submitted to Biomedical Physics & Engineering ExpressBiomed. Phys. Eng. Express 12 035035 (2026)Sarah J. ZouGarry ChinnMuhammad Nasir UllahCraig S. Levin10.1088/2057-1976/ae6e44http://arxiv.org/abs/2604.06482v1Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)2026-04-07T21:34:54ZTime-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.2026-04-07T21:34:54Z57 pages, 10 figuresJiacheng XieHua-Chieh ShaoCan WuRicardo OtazoJie DengMu-Han LinTsuicheng ChiuJacob BuattiViktor IakovenkoYou Zhanghttp://arxiv.org/abs/2604.06020v1Optimizing IMPULSED Acquisition Protocols for Clinical 3T Scanners Through Bayesian Experimental Design2026-04-07T16:17:04ZTo optimize diffusion MRI acquisition protocols for IMPULSED model at clinical 3T scanner using Bayesian experimental design, enabling accurate cellular-scale parameter estimation under realistic scan time and scanner hardware constraints. Expected Information Gain (EIG) was used as the optimization objective to maximize the information content of acquired measurements for IMPULSED model fitting. Bayesian optimization with Gaussian process surrogates efficiently searched the high-dimensional acquisition parameter space, including pulse types (PGSE, OGSEn1, and OGSEn2), diffusion times, and b-values. Optimized protocols were systematically evaluated against a heuristically designed baseline protocol through simulation studies assessing classification accuracy and parameter estimation performance across SNR levels of 5-40. Robustness to optimization assumptions was examined by varying prior distributions and assumed SNR. In-vivo validation was performed using canine tumor data acquired at 3T. The optimized protocol eliminated OGSEn2 acquisitions, concentrated measurements at high b-values, employing concurrently optimized diffusion timing. Compared to the baseline protocol, the optimized design achieved superior classification accuracy for distinguishing cell populations and reduced parameter estimation error across biologically relevant parameter ranges at various SNRs. Performance advantages were consistent across diverse optimization scenarios, demonstrating robustness to prior knowledge and noise assumptions. In-vivo parameter maps showed substantially improved quality and smoothness. Bayesian optimization substantially improves IMPULSED acquisition design for clinical 3T scanners. This principled, algorithm-agnostic framework enables accurate diffusion MRI cytometry under clinical constraints, with potential applications to tumor characterization and treatment monitoring.2026-04-07T16:17:04ZYan DaiXun JiaTodd AguileraKai JiangArely Perez RodriguezIsabelle VanhaezebrouckJie Denghttp://arxiv.org/abs/2604.05847v1Development and Performance of an Instrumentation Laboratory for Infrared Medical Imaging2026-04-07T13:13:22ZWe present an experimental setup and methodology designed to facilitate high-precision thermal measurements required for infrared medical tomography. The approach which is best suited for the study of specialized hardware phantoms comprises a controlled environmental enclosure, infrared detection, internal thermal reference elements, and a comprehensive data acquisition counting chain and protocol. Temporal and spatial corrections applied to sequential thermal images and panoramic projections reduce measurement fluctuations resulting in measurement uncertainty to approximately 25~mK. The capability to resolve weak surface temperature variations, well below 0.1~K, meets the requirement of medical imaging sensitivity. The methodology was validated using wax phantoms with elevated-temperature sources ($ΔT$ = 1.5 to 10~K). Reconstructed 3D thermal tomographic images of hot spots embedded in hardware phantoms are found to be in quantitative agreement with thermocouple measurements and $μCT$ derived source positions. The results demonstrate that the proposed setup and methodology enable high-precision thermal measurements and establish the feasibility of detecting surface temperature variations below 0.1 K, consistent with low-temperature localized internal contrasts ($ΔT =$ 1-3 K) at subsurface depths of a few centimeters, relevant to biological tissue.2026-04-07T13:13:22Z11 pages, 8 figuresAnna FrixouEfstathios StiliarisCostas N. Papanicolashttp://arxiv.org/abs/2604.16444v1Comment on electromagnetic noise cancellation in low-field MRI systems (arXiv:2509.05955v1, 2406.17804v3, 2210.06730v2, and related works)2026-04-07T12:43:55ZIn this Comment, we discuss recent approaches to electromagnetic interference (EMI) mitigation in low-field Magnetic Resonance Imaging (LF-MRI), as presented in arXiv preprints 2509.05955v1, 2406.17804v3, or 2210.06730v2. These and other works explore noise cancellation strategies based on external sensing coils for post-elimination of EMI. We argue that, under realistic conditions, such approaches lead to residual signal contamination that necessarily exceed that obtained with optimal hardware-based pre-elimination.2026-04-07T12:43:55ZComments on arXiv:2509.05955, arXiv:2406.17804, arXiv:2210.06730Joseba AlonsoJosé M. AlgarínTeresa Guallart-Navalhttp://arxiv.org/abs/2503.14094v2Image-Based Metrics in Ultrasound for Estimation of Global Speed-of-Sound2026-04-07T11:59:25ZAccurate speed-of-sound (SoS) estimation is crucial for ultrasound image formation, yet conventional systems often rely on an assumed value for imaging. We propose to leverage conventional image analysis techniques and metrics as a novel and simple approach to estimate tissue SoS. We study eleven metrics in three categories for assessing image quality, image similarity and multi-frame variation, by testing them in numerical simulations and phantom experiments, as well as testing in an in vivo scenario. Among single-frame image quality metrics, conventional Focus and a proposed metric variation on Tenengrad present satisfactory accuracy (5-8\,m/s on phantoms), but only when the metrics are applied after compounding multiple frames. Differential image comparison metrics were more successful overall with errors consistently under 8\,m/s even applied on a single pair of frames. Mutual information and correlation metrics were found to be robust in processing relatively small image patches, making them suitable for focal estimation. We present an in vivo study on breast density classification based on SoS, to showcase clinical applicability. The studied metrics do not require access to raw channel data as they can operate on post-beamformed and/or B-mode data. These image-based methods offer a computationally efficient and data-accessible alternative to existing physics- and model-based approaches for SoS estimation.2025-03-18T10:11:49ZRoman DenkinOrcun Goksel10.1016/j.ultras.2026.108090http://arxiv.org/abs/2604.06280v1DosimeTron: Automating Personalized Monte Carlo Radiation Dosimetry in PET/CT with Agentic AI2026-04-07T11:09:30ZPurpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations.
Materials and Methods: In this retrospective study, DosimeTron was evaluated on a publicly available PSMA-PET/CT dataset comprising 597 studies from 378 male patients acquired on three scanner models (18-F, n = 369; 68-Ga, n = 228). The system uses GPT-5.2 as its reasoning engine and 23 tools exposed via four Model Context Protocol servers, automating DICOM metadata extraction, image preprocessing, MC simulation, organ segmentation, and dosimetric reporting through natural-language interaction. Agentic performance was assessed using diverse prompt templates spanning single-turn instructions of varying specificity and multi-turn conversational exchanges, monitored via OpenTelemetry traces. Dosimetric accuracy was validated against OpenDose3D across 114 cases and 22 organs using Pearson's r, Lin's concordance correlation coefficient (CCC), and Bland-Altman analysis.
Results: Across all prompt templates and all runs, no execution failures, pipeline errors, or hallucinated outputs were observed. Pearson's r ranged from 0.965 to 1.000 (median 0.997; all p < 0.001) and CCC from 0.963 to 1.000 (median 0.996). Mean absolute percentage difference was below 5% for 19 of 22 organs (median 2.5%). Total per-study processing time (SD) was 32.3 (6.0) minutes.
Conclusion: DosimeTron autonomously executed complex dosimetry pipelines across diverse prompt configurations and achieved high dosimetric agreement with OpenDose3D at clinically acceptable processing times, demonstrating the feasibility of agentic AI for patient-specific Monte Carlo dosimetry in PET/CT.2026-04-07T11:09:30ZEleftherios TzanisMichail E. KlontzasAntonios Tzortzakakishttp://arxiv.org/abs/2604.05707v1Untargeted analysis of volatile markers of post-exercise fat oxidation in exhaled breath2026-04-07T11:05:59ZBreath acetone represents a promising non-invasive biomarker for monitoring fat oxidation during exercise. However, its utility is limited by confounding factors, as well as by the fact that significant changes in concentration occur only hours post-exercise, which makes real-time assessment difficult. We performed an untargeted screening for volatile organic compounds (VOCs) that could serve as markers of fat oxidation beyond acetone, and investigated whether breath measurements taken during exercise could predict post-exercise changes in fat oxidation. Nineteen participants completed two 25-min cycling sessions separated by a brief 5-min rest period. VOC emissions were analysed using proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOF-MS) during exercise and after a 90-min recovery period. Blood $β$-hydroxybutyrate (BOHB) concentrations served as the reference marker for fat oxidation. Among 773 relevant analytical features detected in the PTR-TOF-MS measurements, only four signals exhibited strong correlations with BOHB ($ρ$ $\geq$ 0.82, p = 0.0002)-all attributable to acetone or its isotopologues or fragments. End-of-exercise measurements of these signals enabled accurate prediction of participants with substantial post-exercise BOHB changes (F1 score $\geq$ 0.83, accuracy = 0.89). Our study did not reveal any novel breath-based biomarkers of fat oxidation, but it confirmed acetone as the key marker. Moreover, our findings suggest that breath acetone measurements during exercise may already enable basic predictions of post-exercise fat oxidation.2026-04-07T11:05:59ZAndré HomeyerJúlia Blanka SziládiJan-Philipp RedlichJonathan BeauchampY Lan Phamhttp://arxiv.org/abs/2602.16000v2Imaging-Derived Coronary Fractional Flow Reserve: Advances in Physics-Based, Machine Learning, and Physics-Informed Methods2026-04-07T01:14:05ZPurpose of Review Imaging derived fractional flow reserve (FFR) is rapidly evolving beyond conventional computational fluid dynamics (CFD) based pipelines toward machine learning (ML), deep learning (DL), and physics informed approaches that enable fast, wire free, and scalable functional assessment of coronary artery stenosis. This review synthesizes recent advances in computed tomography (CT)- and angiography-based FFR measurement, with particular emphasis on emerging physics-informed neural networks and neural operators (PINNs and PINOs), as well as key considerations for their clinical translation. Recent Findings ML/DL approaches have markedly improved automation and computational speed, enabling prediction of pressure and FFR from anatomical descriptors or angiographic contrast dynamics. However, their real-world performance and generalizability can remain variable and sensitive to domain shift, due to multi-center heterogeneity, interpretability challenges, and differences in acquisition protocols and image quality. Physics informed learning introduces conservation structure and boundary condition consistency into model training, improving generalizability and reducing dependence on dense supervision while maintaining rapid inference. Recent evaluation trends increasingly highlight deployment oriented metrics, including calibration, uncertainty quantification, and quality control gatekeeping, as essential for safe clinical use. Summary The field is converging toward imaging derived FFR methods that are faster, more automated, and more reliable. While ML/DL offers substantial efficiency gains, physics informed frameworks such as PINNs and PINOs may provide a more robust balance between speed and physical consistency. Prospective multi center validation and standardized evaluation will be critical to support broad and safe clinical adoption.2026-02-17T20:46:25Z32 pages 4 tablesTanxin ZhuEmran HossenChen ZhaoJingfeng JiangMichele EspositoJiguang SunWeihua Zhouhttp://arxiv.org/abs/2604.06257v1mach: ultrafast ultrasound beamforming2026-04-06T22:34:29ZPurpose:
Volumetric ultrafast ultrasound produces massive datasets with high frame rates, dense reconstruction grids, and large channel counts. Beamforming computational demands limit research throughput and prevent real-time applications in emerging modalities such as elastography, functional neuroimaging, and microscopy.
Approach:
We developed mach, an open-source, GPU-accelerated beamformer with a highly optimized delay-and-sum CUDA kernel and an accessible Python interface. mach uses a hybrid delay computation strategy that substantially reduces memory overhead compared to fully precomputed approaches. The CUDA implementation optimizes memory layout for coalesced access and reuses delay computations across frames via shared memory. We benchmarked mach on the PyMUST rotating disk dataset and validated numerical accuracy against existing open-source beamformers.
Results:
mach processes 1.1 trillion points per second on a consumer-grade GPU, achieving $>$10$\times$ faster performance than existing open-source GPU beamformers. On the PyMUST rotating disk benchmark, mach completes reconstruction in 0.23~ms, 6$\times$ faster than the acoustic round-trip time to the imaging depth. Validation against other beamformers confirms numerical accuracy with errors below $-60$~dB for Power Doppler and $-120$~dB for B-mode.
Conclusions:
mach achieves 1.1 trillion points per second throughput, enabling real-time 3D ultrafast ultrasound reconstruction for the first time on consumer-grade hardware. By eliminating the beamforming bottleneck, mach enables real-time applications such as 3D functional neuroimaging, intraoperative guidance, and ultrasound localization microscopy. mach is freely available at https://github.com/Forest-Neurotech/mach2026-04-06T22:34:29Z17 pages, 8 figures, 5 tables. LaTeX. Published in SPIE Journal of Medical Imaging. Source code and package: https://github.com/Forest-Neurotech/machJ. Med. Imag. 13(6), 062203 (2026)Charles GuanAlexander P. RockhillMasashi SodeGianmarco Pinton10.1117/1.JMI.13.6.062203http://arxiv.org/abs/2604.01710v2High-resolution ultra-low-field MRI with SNRAware denoising2026-04-05T09:37:04ZUltra-low-field (ULF, <0.1 T) magnetic resonance imaging (MRI) systems offer advantages in cost, portability, and accessibility, but their current utility is still limited by low signal-to-noise ratio (SNR). Deep learning (DL)-based denoising has emerged as a potential strategy to mitigate this limitation. In this work, we present a systematic evaluation of a high-performance DL denoising model trained using the SNRAware framework and applied to 88 mT and 72 mT data. Using a series of controlled experiments, we assessed model performance as a function of spatial resolution, coil impedance matching, readout bandwidth, input noise level, k-space undersampling, anatomy, image contrast, and scanner platform, and compared against analytical denoising algorithms. The model consistently increased the effective SNR of ULF acquisitions, enabling images with nominal spatial resolutions comparable to those commonly used in clinical 3 T protocols. Residual analyses indicated that the model predominantly removed stochastic noise while preserving underlying signal structure. At the same time, the results highlight some constraints: denoising performance remains dependent on the starting SNR of the acquisition, and training-domain mismatch influences behavior under certain artifact conditions. These findings suggest that DL-based denoising can significantly expand the practical capabilities of ULF MRI, while emphasizing potential benefits from hardware-software co-optimization and the need for rigorous clinical validation to determine the diagnostic value of denoised images.2026-04-02T07:23:45Z13 pages, 9 figures, comments welcomeTeresa Guallart-NavalHui XueJosé M. AlgarínEli G. CastanonJesús ConejeroFernando GalveMary A. NassejjeJohn StairsLorena Vega-CidMichael HansenJoseba Alonsohttp://arxiv.org/abs/2604.03967v1Dose Validation of GRID Block Treatment Applicator within the RayStation Treatment Planning System2026-04-05T05:05:39ZSpatially Fractionated Radiation Therapy (SFRT) or GRID therapy has been in existence for more than a century. GRID therapy was invented as an approach to address the challenges posed by bulky tumors. To treat patients with GRID therapy, the protocol needs to be implemented within the Treatment Planning System (TPS) software. Also, the dose needed for treatment must be validated. A few TPS software vendors such as Elekta and Varian have protocols for treating patients with GRID therapy. However, we are the first to implement the protocols within RayStation TPS. To achieve these, we used the .decimal GRID block applicator to create conformal treatment plans. For the beam modeling, several dosimetry data, and measurements such as percentage depth dose (PDD), beam profile, output, and GRID factors, were obtained for different field sizes and energies. The dose distribution from the GRID openings covered the Planning Target Volume (PTV), with the QA plan having a 98% agreement with the planned dose. Also, we used the Mapcheck2 results to verify the adjustments made to the script variables such as aperture size (hole and spacing). We developed a robust way to validate the dose needed for patient treatment using the GRID block applicator. Also, we have proposed a novel approach to standardize the clinical implementation of the GRID block in RayStation TPS.2026-04-05T05:05:39ZBlessing AkahEdwin QuashieGene Cardarellihttp://arxiv.org/abs/2604.04966v1Head Coil-Mounted Vision Correction Device for Magnetic Resonance Imaging2026-04-04T01:18:02ZCorrection for nearsightedness and farsightedness is an important concern for functional magnetic resonance imaging (fMRI) experiments involving visual stimuli in humans. In the absence of personal contact lenses, spherical refractive errors are typically corrected using interchangeable lenses mounted in goggles or glasses frames worn by the participant, or mounted on the head coil during scanning. The coil-mounted device described here avoids the ergonomic challenges encountered with head-mounted goggles and addresses limitations of prior coil-mounted designs, including ease of lens switching and inter-pupillary distance adjustments. Our device can be 3D printed economically with MRI-compatible plastics, including PLA.2026-04-04T01:18:02ZAleksandar MarinkovicJulian Michael Tyszka