https://arxiv.org/api/QlSoo4f7ZOhPaYo2y9T4Wri4cTU 2026-04-09T17:22:10Z 8808 240 15 http://arxiv.org/abs/2601.20457v1 TIARA: a fast gamma-ray detector for range monitoring in Proton Therapy 2026-01-28T10:31:26Z We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF$_2$ crystal (2 $\times$ 1.5 $\times$ 1.5 cm$^{3}$) coupled to a 2 $\times$ 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF$_2$ allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2$σ$ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of $\mathbf{\sim}$10$\mathbf{^{7}}$ protons. 2026-01-28T10:31:26Z A. André M. Pinson C. Hoarau Y. Boursier M. Dupont L. Gallin Martel M. -L. Gallin Martel A. Garnier J. Hérault J. -P. Hofverberg P. Kavrigin C. Morel J. -F. Muraz M. Pullia S. Savazzi D. Maneval S. Marcatili http://arxiv.org/abs/2510.18387v2 Quantification of dual-state 5-ALA-induced PpIX fluorescence: Methodology and validation in tissue-mimicking phantoms 2026-01-28T10:22:31Z Quantification of protoporphyrin IX (PpIX) fluorescence in human brain tumours has the potential to significantly improve patient outcomes in neuro-oncology, but represents a formidable imaging challenge. Protoporphyrin is a biological molecule which interacts with the tissue micro-environment to form two photochemical states in glioma. Each exhibits markedly different quantum efficiencies, with distinct but overlapping emission spectra that also overlap with tissue autofluorescence. Fluorescence emission is known to be distorted by the intrinsic optical properties of tissue, coupled with marked intra-tumoural heterogeneity as a hallmark of glioma tumours. Existing quantitative fluorescence systems are developed and validated using simplified phantoms that do not simultaneously mimic the complex interactions between fluorophores and tissue optical properties or micro-environment. Consequently, existing systems risk introducing systematic errors into PpIX quantification when used in tissue. In this work, we introduce a novel pipeline for quantification of PpIX in glioma, which robustly differentiates both emission states from background autofluorescence without reliance on a priori spectral information, and accounts for variations in their quantum efficiency. Unmixed PpIX emission forms are then corrected for wavelength-dependent optical distortions and weighted for accurate quantification. Significantly, this pipeline is developed and validated using novel tissue-mimicking phantoms replicating the optical properties of glioma tissues and photochemical variability of PpIX fluorescence in glioma. Our workflow achieves strong correlation with ground-truth PpIX concentrations (R2 = 0.918+-0.002), demonstrating its potential for robust, quantitative PpIX fluorescence imaging in clinical settings. 2025-10-21T08:07:14Z Silvère Ségaud Charlie Budd Matthew Elliot Graeme Stasiuk Jonathan Shapey Yijing Xie Tom Vercauteren 10.1088/1361-6560/ae45e6 http://arxiv.org/abs/2501.10764v2 Energy-Threshold Bias Calculator: A Physics-Model Based Adaptive Correction Scheme for Photon-Counting CT 2026-01-28T10:07:20Z Photon-counting detector based computed tomography (PCCT) has greatly advanced in recent years. However, spectral inconsistency, referring to inter-pixel variations in detected counts per energy bin, can easily leads to ring or band artifacts and inaccuracies in CT reconstructed images. This work proposes a novel physics-model based method to correct for spectral inconsistency by modeling it through two terms: (1) a fixed spectral skew term (energy threshold-independent filtration function) determined at a given energy threshold, and (2) a variable energy-threshold bias term that can be directly calculated by using our spectral model as the threshold changes. After the two terms being computed out in the calibration stage, they will be incorporated into our spectral model to adaptively generate the spectral correction vectors as well as the material decomposition vectors if needed, pixel-by-pixel for PCCT projection data. Using a minimum set of parameters with explicit physics meaning, such an energy-threshold bias calculator (ETB-Cal) has advantages of computational efficiency, robustness in implementation, and convenience with no need of X-ray fluorescence materials in calibration. To validate our method, both numerical simulations and physical experiments using multiple phantoms were carried out on a tabletop PCCT system, with preliminary results showing a significant reduction in non-uniformity, from 29.3 to 5.8 HU for Gammex multi-energy phantom versus no correction (comparatively, 8.3 HU was achieved by a polynomial-involving model-based approach with no explicit modeling and calculating of energy threshold bias but more calibration data required), and from 27.9 to 3.2 HU for the Kyoto head phantom. 2025-01-18T13:32:17Z 18 pages, 14 figures IEEE Trans. Med. Imaging, early access, 2026 Yuting Chen Yuxiang Xing Li Zhang Zhi Deng Hewei Gao 10.1109/TMI.2026.3654612 http://arxiv.org/abs/2601.20291v1 A Learning-based Framework for Spatial Impulse Response Compensation in 3D Photoacoustic Computed Tomography 2026-01-28T06:18:20Z Photoacoustic computed tomography (PACT) is a promising imaging modality that combines the advantages of optical contrast with ultrasound detection. Utilizing ultrasound transducers with larger surface areas can improve detection sensitivity. However, when computationally efficient analytic reconstruction methods that neglect the spatial impulse responses (SIRs) of the transducer are employed, the spatial resolution of the reconstructed images will be compromised. Although optimization-based reconstruction methods can explicitly account for SIR effects, their computational cost is generally high, particularly in three-dimensional (3D) applications. To address the need for accurate but rapid 3D PACT image reconstruction, this study presents a framework for establishing a learned SIR compensation method that operates in the data domain. The learned compensation method maps SIR-corrupted PACT measurement data to compensated data that would have been recorded by idealized point-like transducers. Subsequently, the compensated data can be used with a computationally efficient reconstruction method that neglects SIR effects. Two variants of the learned compensation model are investigated that employ a U-Net model and a specifically designed, physics-inspired model, referred to as Deconv-Net. A fast and analytical training data generation procedure is also a component of the presented framework. The framework is rigorously validated in virtual imaging studies, demonstrating resolution improvement and robustness to noise variations, object complexity, and sound speed heterogeneity. When applied to in-vivo breast imaging data, the learned compensation models revealed fine structures that had been obscured by SIR-induced artifacts. To our knowledge, this is the first demonstration of learned SIR compensation in 3D PACT imaging. 2026-01-28T06:18:20Z Submitted to IEEE TMI Kaiyi Yang Seonyeong Park Gangwon Jeong Hsuan-Kai Huang Alexander A. Oraevsky Umberto Villa Mark A. Anastasio http://arxiv.org/abs/2601.19994v1 A Practical Computational Hemolysis Model Incorporating Biophysical Properties of the Red Blood Cell Membrane 2026-01-27T19:01:09Z Purpose: Hemolysis is a key issue in the design of blood-handling medical devices. Computational prediction of this phenomenon is challenging due to the complex multiscale nature of blood. As a result, conventional approaches often fail to predict hemolysis accurately, commonly showing deviations of multiple orders of magnitude compared to experimental data. More accurate models are typically computationally expensive and thus impractical for real-world applications. This work aims to fill this gap by presenting accurate yet simple and efficient computational hemolysis models. Methods: Hemolysis modeling relies on two key components: a red blood cell model and a hemoglobin release model. In this work, we compare three red blood cell models: a common stress-based model (Bludszuweit), a simple strain-based model based on the Kelvin-Voigt constitutive law, and a more complex tensor-based model (TTM). Further, we compare two hemoglobin release models: the widely used power-law approach and a biophysical pore formation model. Results: We evaluate these models in two benchmark cases: the FDA blood pump and the FDA nozzle. In both benchmarks, the simple strain-based model combined with the pore formation model achieves absolute predictions of hemolysis within the standard deviation of experimental measurements. In contrast, stress-based power law models deviate by several orders of magnitude. Conclusion: The strain-based pore modeling approach takes into account the biophysical properties of red blood cell membranes, in particular their viscoelastic deformation behavior and hemoglobin release through membrane pores. This leads to significantly improved hemolysis predictions in a framework that can easily be integrated into common CFD workflows. 2026-01-27T19:01:09Z 34 pages, 7 figures Nico Dirkes Marek Behr http://arxiv.org/abs/2507.06958v2 Experimental and computational dosimetry in an integrated workflow for remote audits in Ir-192 interstitial brachytherapy: Development and pilot implementation 2026-01-27T17:20:56Z Purpose: This work describes the development and pilot implementation of a comprehensive remote dosimetry audit for Ir-192 high-dose-rate interstitial brachytherapy, integrating independent experimental and computational dosimetry within a unified workflow.Methods: A compact water-equivalent phantom accommodating two plastic catheters, ten optically stimulated luminescent dosimeters (OSLDs), and two radiochromic films was designed to enable independent point-approximating and 2D dose measurements. A user-selected treatment plan with 36 source dwell positions was generated in a clinical treatment planning system (TPS), accounting for dosimeter dose ranges. Computational audit testing was performed by analyzing DICOM-RT files and conducting Monte Carlo (MC) simulations to obtain independent 3D dose calculations for the same plan and phantom geometry. Dosimetry results were compared to TPS calculations (TG43 and a Model Based Dose Calculation Algorithm, MBDCA) using the 3D Gamma Index (GI) test, dose difference maps, and dose-volume histogram comparisons, wherever applicable. Procedures were optimized to minimize clinical workload.Results:The pilot study was completed within ten days of phantom delivery. Measurement corrections were applied when necessary using correction factors from side studies. GI criteria were adapted to the uncertainty of each dosimetry system. Excellent agreement between MBDCA and experimental or MC results was observed. Within the volume of interest, TG-43 systematically overestimated dose relative to MC results (median difference: +2.16%), attributed to missing scatter conditions and phantom material.Conclusion:Despite the labor-intensive workflow, the protocol is suitable for remote Ir-192 audits with acceptable uncertainties. Combining experimental and computational dosimetry enhances audit robustness and supports comprehensive brachytherapy auditing programs. 2025-07-09T15:40:15Z Published in Journal of Applied Clinical Medical Physics Eleftherios P Pappas Vasiliki Peppa Alexandra Drakopoulou Eleni Velissariou Zoi Thrapsanioti Georgios Kollias Efi Koutsouveli Georgia Lymperopoulou Pantelis Karaiskos http://arxiv.org/abs/2601.19962v1 Controlled drug delivery from chitosan-coated heparin-loaded nanopores anodically grown on nitinol shape-memory alloy 2026-01-27T10:51:57Z Nitinol (NiTi shape-memory alloy) is an interesting candidate in various medical applications like dental, orthopedic, and cardiovascular devices, owing to its unique mechanical behaviors and proper biocompatibility. The aim of this work is the local controlled delivery of a cardiovascular drug, heparin, loaded onto nitinol treated by electrochemical anodizing and chitosan coating. In this regard, the structure, wettability, drug release kinetics, and cell cytocompatibility of the specimens were analyzed in vitro. The two-stage anodizing process successfully developed a regular nanoporous layer of Ni-Ti-O on nitinol, which considerably decreased the sessile water contact angle and induced hydrophilicity. The application of the chitosan coatings controlled the release of heparin mainly by a diffusional mechanism, where the drug release mechanisms were evaluated by the Higuchi, first-order, zero-order, and Korsmeyer-Pepass models. Human umbilical cord endothelial cells (HUVECs) viability assay also showed the non-cytotoxicity of the samples, so that the best performance was found for the chitosan-coated samples. It is concluded that the designed drug delivery systems are promising for cardiovascular, particularly stent applications. 2026-01-27T10:51:57Z Carbohydrate polymers, 314 (2023) 120961 M. Moradi E. Salahinejad E. Sharifi L. Tayebi 10.1016/j.carbpol.2023.120961 http://arxiv.org/abs/2601.19246v1 Magnetic Resonance Simulation of Effective Transverse Relaxation (T2*) 2026-01-27T06:28:52Z Purpose: To simulate effective transverse relaxation ($T_2^*$) as a part of MR simulation. $T_2^*$ consists of reversible ($T_2^{\prime}$) and irreversible ($T_2$) components. Whereas simulations of $T_2$ are easy, $T_2^{\prime}$ is not easily simulated if only magnetizations of individual isochromats are simulated. Theory and Methods: Efficient methods for simulating $T_2^{\prime}$ were proposed. To approximate the Lorentzian function of $T_2^{\prime}$ realistically, conventional simulators require 100+ isochromats. This approximation can be avoided by utilizing a linear phase model for simulating an entire Lorentzian function directly. To represent the linear phase model, the partial derivatives of the magnetizations with respect to the frequency axis were also simulated. To accelerate the simulations with these partial derivatives, the proposed methods introduced two techniques: analytic solutions, and combined transitions. For understanding the fundamental mechanism of the proposed method, a simple one-isochromat simulation was performed. For evaluating realistic cases, several pulse sequences were simulated using two phantoms with and without $T_2^{\prime}$ simulations. Results: The one-isochromat simulation demonstrated that $T_2^{\prime}$ simulations were possible. In the realistic cases, $T_2^{\prime}$ was recovered as expected without using 100+ isochromats for each point. The computational times with $T_2^{\prime}$ simulations were only 2.0 to 2.7 times longer than those without $T_2^{\prime}$ simulations. When the above-mentioned two techniques were utilized, the analytic solutions accelerated 19 times, and the combined transitions accelerated up to 17 times. Conclusion: Both theory and results showed that the proposed methods simulated $T_2^{\prime}$ efficiently by utilizing a linear model with a Lorentzian function, analytic solutions, and combined transitions. 2026-01-27T06:28:52Z Hidenori Takeshima http://arxiv.org/abs/2601.19025v1 On the Application of Fractional Order Derivatives for Characterizing Brain White Matter Viscoelasticity 2026-01-26T23:20:36Z Conventional viscoelastic characterization of brain white matter (BWM), typically described using Prony series models, remains a largely empirical representation that is difficult to interpret physically. Growing evidence suggests that BWMviscoelasticity follows power-law behavior. Under the assumptions of linear viscoelasticity and causality, a power-law model in the frequency domain yields a fractional viscoelastic model in the time domain. A fractional viscoelastic constitutive model for the axon and extracellular matrix (ECM) is implemented via a Fortran VUMAT subroutine. A biphasic periodic finite element (FE) model of hexagonally packed representative volume elements (RVEs) of axons embedded in an ECM is constructed in Abaqus under quasi-static loading. The inverse problem of extracting homogenized material properties is solved using an optimization workflow. The model predicts that the springpot coefficient, which determines the solid-fluid behavior and, the power-law exponent, which encodes information about the underlying tissue architecture, follows a bi-logistic function along the transverse normal and shear directions. The nonlinear variation of the parameters reveals two distinct stiffening stages: a lower rate at low axon volume fractions, followed by a higher rate as increased axonal content reinforces the RVE. To our knowledge, this study is the first to propose and implement a 3D fractional viscoelastic FE model of the corpus callosum of BWM in the time domain. The thread-safe implementation of the VUMAT achieves significantly faster performance than existing approaches. The results reveal nonlinear variation in material parameters, directional dependence of BWM mechanics, and the complex interplay among microstructural elements. 2026-01-26T23:20:36Z 24 pages, 18 figures P. Pasupathy J. G. Georgiadis A. A Pelegri http://arxiv.org/abs/2507.05144v2 Clinical test cases for commissioning, QA, and benchmarking of model-based dose calculation algorithms in 192Ir HDR gynecologic tandem and ring brachytherapy 2026-01-26T17:10:44Z Purpose: To develop clinically relevant test cases for commissioning Model-Based Dose Calculation Algorithms (MBDCAs) for 192Ir High Dose Rate (HDR) gynecologic brachytherapy following the workflow proposed by the TG-186 report and the WGDCAB report 372. Acquisition and Validation Methods: Two cervical cancer intracavitary HDR brachytherapy patient models were created, using either uniformly structured regions or realistic segmentation. The computed tomography (CT) images of the models were converted to DICOM CT images via MATLAB and imported into two Treatment Planning Systems (TPSs) with MBDCA capability. The clinical segmentation was expanded to include additional organs at risk. The actual clinical treatment plan was generally maintained, with the source replaced by a generic 192Ir HDR source. Dose to medium in medium calculations were performed using the MBDCA option of each TPS, and three different Monte Carlo (MC) simulation codes. MC results agreed within statistical uncertainty, while comparisons between MBDCA and MC dose distributions highlighted both strengths and limitations of the studied MBDCAs, suggesting potential approaches to overcome the challenges. Data Format and Usage Notes: The datasets for the developed cases are available online at http://doi.org/ 10.5281/zenodo.15720996. The DICOM files include the treatment plan for each case, TPS, and the corresponding reference MC dose data. The package also contains a TPS- and case-specific user guide for commissioning the MBDCAs, and files needed to replicate the MC simulations. Potential Applications: The provided datasets and proposed methodology offer a commissioning framework for TPSs using MBDCAs, and serve as a benchmark for brachytherapy researchers using MC methods. They also facilitate intercomparisons of MBDCA performance and provide a quality assurance resource for evaluating future TPS software updates. 2025-07-07T15:55:54Z Published in Medical Physics V. Peppa M. Robitaille F. Akbari S. A. Enger R. M. Thomson F. Mourtada G. P. Fonseca http://arxiv.org/abs/2601.18843v1 Human Cardiac Measurements with Diamond Magnetometers 2026-01-26T11:42:13Z We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG). 2026-01-26T11:42:13Z Muhib Omar Magnus Benke Shaowen Zhang Jixing Zhang Michael Kuebler Pouya Sharbati Ara Rahimpour Arno Gueck Maryna Kapitonova Devyani Kadam Carlos Rene Izquierdo Geiser Jens Haller Arno Trautmann Katharina Jag-Lauber Robert Roelver Thanh-Duc Nguyen Leonardo Gizzi Michelle Schweizer Mena Abdelsayed Ingo Wickenbrock Andrew M. Edmonds Matthew Markham Peter A. Koss Oliver Schnell Ulrich G. Hofmann Tonio Ball Juergen Beck Dmitry Budker Joerg Wrachtrup Arne Wickenbrock http://arxiv.org/abs/2601.18219v1 Automated HER2 scoring with uncertainty quantification using lensfree holography and deep learning 2026-01-26T07:09:08Z Accurate assessment of human epidermal growth factor receptor 2 (HER2) expression is critical for breast cancer diagnosis, prognosis, and therapy selection; yet, most existing digital HER2 scoring methods rely on bulky and expensive optical systems. Here, we present a compact and cost-effective lensfree holography platform integrated with deep learning for automated HER2 scoring of immunohistochemically stained breast tissue sections. The system captures lensfree diffraction patterns of stained HER2 tissue sections under RGB laser illumination and acquires complex field information over a sample area of ~1,250 mm^2 at an effective throughput of ~84 mm^2 per minute. To enhance diagnostic reliability, we incorporated an uncertainty quantification strategy based on Bayesian Monte Carlo dropout, which provides autonomous uncertainty estimates for each prediction and supports reliable, robust HER2 scoring, with an overall correction rate of 30.4%. Using a blinded test set of 412 unique tissue samples, our approach achieved a testing accuracy of 84.9% for 4-class (0, 1+, 2+, 3+) HER2 classification and 94.8% for binary (0/1+ vs. 2+/3+) HER2 scoring with uncertainty quantification. Overall, this lensfree holography approach provides a practical pathway toward portable, high-throughput, and cost-effective HER2 scoring, particularly suited for resource-limited settings, where traditional digital pathology infrastructure is unavailable. 2026-01-26T07:09:08Z 23 Pages, 6 Figures, 1 Table Che-Yung Shen Xilin Yang Yuzhu Li Leon Lenk Aydogan Ozcan http://arxiv.org/abs/2601.18082v1 Feedback-Based Quantum Control for Safe and Synergistic Drug Combination Design 2026-01-26T02:30:38Z Drug-drug interactions (DDIs) strongly affect the safety and efficacy of combination therapies. Despite the availability of large DDI databases, selecting optimal multi-drug combinations that balance safety, therapeutic benefit, and regimen size remains a challenging combinatorial optimization problem. Here, we present a quantum-control-based framework for DDI-aware drug combination optimization, in which known harmful and synergistic interactions are encoded into Ising Hamiltonians as penalties and rewards, respectively. The optimization is performed using the feedback-based quantum algorithm FALQON, a gradient-free variational approach. We study two clinically motivated tasks: the Maximum Safe Subset problem and the Synergy-Constrained Optimization problem. Numerical simulations using interaction data from Drugs.com and SYNERGxDB demonstrate efficient convergence and high-quality solutions for clinically relevant drug sets, including COVID-19 case studies. 2026-01-26T02:30:38Z 11 pages, 7 figures Mai Nguyen Phuong Nhi Lan Nguyen Tran Le Bin Ho http://arxiv.org/abs/2601.18021v1 MlPET: A Localized Neural Network Approach for Probabilistic Post-Reconstruction PET Image Analysis Using Informed Priors 2026-01-25T22:41:50Z We develop and evaluate MlPET, a fast localized machine learning approach for probabilistic PET image analysis addressing the noise-resolution trade-off in conventional reconstructions. MlPET replaces computationally demanding Markov chain Monte Carlo sampling with a localized neural network trained to estimate posterior mean voxel activity from small image neighborhoods. The method incorporates scanner-specific point spread functions, spatially correlated noise modeling, and flexible priors. Performance was evaluated on NEMA IEC phantom data from three PET systems (GE Discovery MI, Siemens Biograph Vision 600, and Quadra) under varying reconstruction settings and acquisition times. On phantom data, MlPET achieved contrast recovery coefficients consistently higher than standard PET and close to 1.0 (including 10 mm spheres), while reducing background noise and improving spatial definition. Effective pointspread function full width at half maximum decreased from approximately 2 mm in standard PET to below 1 mm with MlPET, a 2.5 fold reduction in blur. Comparable image quality was obtained at 40-80 s acquisition time with MlPET versus 900 s with conventional PET. MlPET provides an efficient approach for quantitative probabilistic post-reconstruction PET analysis. By combining informed priors with neural network speed, it achieves noise suppression and resolution enhancement without altering reconstruction algorithms. The method shows promise for improved small-lesion detectability and quantitative reliability in clinical PET imaging. Future studies will evaluate performance on patient data. 2026-01-25T22:41:50Z Thomas Mejer Hansen Nana Christensen Mikkel Vendelbo http://arxiv.org/abs/2601.19948v1 Advances in ion-doping of Ca-Mg silicate bioceramics for bone tissue engineering 2026-01-25T21:05:30Z The use of bioceramics as hard tissue substitutes is extensive due to their excellent biocompatible and osteogenic behaviors. Among various bioceramics, Ca-Mg silicates are unique from the viewpoints of osteoinductive and mechanical properties, as well as their outstanding osteoconductive and angiogenic behaviors owing to the release of Si, Ca and Mg. Despite these distinct advantages, different compositions of these bioceramics still require mechanical and biological enhancements for further applications. For this purpose, doping with some ions like F-, Sr2+, Cu2+, Eu2+, Ba+, Ce3+ and some alkali cations has been proved to be a valued approach. This review attempts to bring together areas for the performance improvement of the further researched Ca-Mg silicates (i.e., diopside, akermanite, bredigite and monticellite) and the alteration of these compositions via ion-doping. It is concluded that a correct choice of dopants incorporated at the optimal concentration makes these silicates ideal bone substitutes competing or even superior to calcium phosphates (apatites) and bioglasses which are known as the most prominent bioceramics. 2026-01-25T21:05:30Z Coordination Chemistry Reviews, 478 (2023) 215001 Ashkan Namdar Erfan Salahinejad 10.1016/j.ccr.2022.215001