https://arxiv.org/api/1xNNO2vr71UlSW/0+YM5SQqKZ602026-04-09T15:59:00Z880822515http://arxiv.org/abs/2602.00283v1A Novel Differential Pathlength Factor Model for Near-Infrared Diffuse Optical Imaging2026-01-30T20:13:50ZNear infrared diffuse optical imaging can be performed in reflectance and transmission mode and relies on physical models along with measurements to extract information on changes in chromophore concentration. Continuous-wave near-infrared diffuse optical imaging relies on accurate differential pathlength factors (DPFs) for quantitative chromophore estimation. Existing DPF definitions inherit formulation-dependent limitations that can introduce large errors in modified Beer--Lambert law analyses. These errors are significantly higher at smaller source-detector separations in a reflectance mode of measurement. This minimizes their applicability in situations where large area detection is used and also when signal depth is varying. Using Monte Carlo simulations, we derive two distance- and property-dependent DPF models one ideal and one experimentally practical and benchmark them against standard formulations. The proposed models achieve errors below 10 percent across broad optical conditions, whereas conventional DPFs can exceed 100 percent error. The theoretical predictions are further validated using controlled phantom experiments, demonstrating improved quantitative accuracy in CW-NIR imaging.2026-01-30T20:13:50Z16 pages, 6 figuresKaiser NiknamMannu Bardhan PaulMini Dashttp://arxiv.org/abs/2502.20112v2Monte Carlo simulation of the ISOLPHARM gamma camera for Ag-111 imaging2026-01-30T19:55:05ZTargeted Radionuclide Therapy (TRT) is a well-established technique for cancer treatment. In this approach, radionuclides are bound to specific drugs that selectively transport them to the tumor site. Within the ISOLPHARM project, a radiopharmaceutical for TRT based on the innovative radionuclide Ag-111 is currently under development. Ag-111 has a half-life of 7.45 days and decays by emitting both electrons and gamma-rays. The emission of gamma-rays, predominantly at an energy of 342 keV, enables the visualization of Ag-111 using a gamma camera. In this work, we describe a Monte Carlo simulation developed to optimize the design parameters of such an imaging device. The simulation is based on the Geant4 toolkit, which accurately models the interactions between particles and matter. The estimated spatial resolution and sensitivity of the system are approximately 4 mm and 19 cps/MBq, respectively. The simulated device is able to resolve lesions with a lesion-to-background activity ratio of 4:1 under in-vivo-like conditions. These results indicate that the proposed gamma camera can provide cost-effective imaging capabilities for preclinical radiopharmaceutical studies.2025-02-27T14:03:49Z10 pages, 5 figures, to be published in JINST for the conference ICFDT7. New version was produced according to the reviewers commentsD. SerafiniA. LesoA. ArzentonS. SpadanoE. BorcianiD. ChenC. SbarraM. NegriniA. MargottiN. LanconelliG. BaldazziE. MariottiS. CorradettiA. Andrighettohttp://arxiv.org/abs/2409.03010v4Geometry of the cumulant series in diffusion MRI2026-01-30T19:53:39ZWater diffusion gives rise to micron-scale sensitivity of diffusion MRI (dMRI) to cellular-level tissue structure. Precision medicine and quantitative imaging depend on uncovering the information content of dMRI and establishing its parsimonious hardware-independent fingerprint. Based on the rotational SO(3) symmetry, we study the geometry of the dMRI signal and the topology of its acquisition, identify irreducible components and a full set of invariants for the cumulant tensors, and relate them to tissue properties. Including all kurtosis invariants improves multiple sclerosis classification in a cohort of 1189 subjects. We design the shortest acquisitions based on icosahedral vertices to determine the most used invariants in only 1-2 minutes for whole brain. Representing dMRI via scalar invariant maps with definite symmetries will underpin machine learning classifiers of pathology, development, and aging, while fast protocols will enable translation of advanced dMRI into clinic.2024-09-04T18:04:32ZSantiago CoelhoJenny ChenFilip SzczepankiewiczEls FieremansDmitry S. Novikovhttp://arxiv.org/abs/2511.03493v2Performance Evaluation of a Position-Sensitive SiPM-based Gamma Camera for Intraoperative Imaging2026-01-30T19:24:58ZThe POSiCS camera is a handheld, small field-of-view gamma camera developed for multipurpose use in radio-guided surgery (RGS), with sentinel lymph node biopsy (SLNB) as its benchmark application. This compact and lightweight detector (weighing approximately 350 g) can map tissues labeled with Tc-99m nanocolloids and guide surgeons to the location of target lesions. By enabling intraoperative visualization in close proximity to the surgical field, its primary objective is to minimize surgical interventional invasiveness and operative time, thereby enhancing localization accuracy and reducing the incidence of post-operative complications. The design and components of the POSiCS camera emphasize ergonomic handling and compactness, providing, at the same time, rapid image formation and a spatial resolution of a few millimeters. These features are compatible with routine operating-room workflow, including wireless communication with the computer and a real-time display to support surgeon decision-making.
The spatial resolution measured at a source-detector distance of 0 cm was 1.9 +/- 0.1 mm for the high-sensitivity mode and 1.4 +/- 0.1 mm for the high-resolution mode. The system sensitivity at 2 cm was evaluated as 481 +/- 14 cps/MBq (high sensitivity) and 134 +/- 8 cps/MBq (high resolution). For both working modes, we report an energy resolution of approximately 20 percent, even though the high-resolution collimator exhibits an increased scattered component due to the larger amount of tungsten.2025-11-05T14:23:15Z26 pages, 11 figures, Performance PaperAramis RaiolaFabio AcerbiCyril AlispachDomenico della VolpeHossein ArabiAlberto GolaHabib Zaidihttp://arxiv.org/abs/2508.12827v2Towards a better understanding of abdominal wall biomechanics: in vivo relationship between dynamic intra-abdominal pressure and magnetic resonance imaging measurements2026-01-30T10:29:08ZBackground In vivo mechanical behaviour of the abdominal wall has been poorly characterised and important details are missing regarding the occurrence and post-operative recurrence rate of hernias which can be as high as 30 %. This study aimed to assess the correlation between abdominal wall displacement and intra-abdominal pressure, as well as abdominal compliance. Methods Eighteen healthy participants performed audio-guided passive (breathing) and active (coughing, Valsalva maneuver) exercises. Axial dynamic changes of abdominal muscles and visceral area were measured using MRI, and intra-abdominal pressure with ingested pressure sensor. Findings Correlations between abdominal wall displacement and intra-abdominal pressure were specific to participant, exercise, and varying between rectus abdominis and lateral muscles. Strong correlations were found between rectus abdominis displacement and intra-abdominal pressure during breathing (r = 0.92 $\pm$ 0.06), as well as lateral muscles displacement with intra-abdominal pressure during coughing and Valsalva maneuver (r = --0.98 $\pm$ 0.03 and -- 0.94 $\pm$ 0.05 respectively). The abdominal pseudo-compliance varied greatly among participants during muscular contraction, the coefficient of variation reaching up to 70 %. Interpretation The combination of intra-abdominal pressure and dynamic MRI measurements enables the identification of participant-specific behaviour pattern. Intra-abdominal pressure and abdominal wall dynamic undergo consistent and predictable interactions. However, this relationship is subject-specific and may not be extrapolated to other individuals. Therefore, both intra-abdominal pressure and abdominal wall motion must be measured in the same participant in order to accurately characterise the abdominal wall behaviour. These results are of great importance for mesh design, surgical decision-making, and personalised healthcare.2025-08-18T11:12:03ZClinical Biomechanics, 2024, 121, pp.106396Victoria JoppinLBA UMR T24, CRMBMArthur JourdanLBA UMR T24David BendahanCRMBMAndréa SoucasseLBA UMR T24Maxime GuyeCRMBM, TIMONECatherine MassonLBA UMR T24Thierry BègeLBA UMR T24http://arxiv.org/abs/2601.22793v1Fast Eikonal Phase Retrieval for High-Throughput Beamlines2026-01-30T10:15:23ZWe introduce a fast Eikonal Phase Retrieval (EPR) formulation that accelerates eikonal phase retrieval by more than two orders of magnitude while retaining controlled accuracy. The method is derived from a second-order asymptotic expansion in the propagation distance $L$ and complemented by the leading Wentzel--Kramers--Brillouin (WKB)
wave-optics correction, yielding an efficient iterative correction scheme preconditioned by FFT-diagonal, energy-dependent inverse operators (Paganin-type filters). To ensure robustness across practical experimental regimes, we combine two complementary solvers: (i) a local $O(L^2)$ closure that is accurate when eikonal shifts remain sub-pixel, and (ii) a non-local formulation for multi-pixel shifts, in which intensity is propagated through an explicit eikonal ray mapping using a mass-conserving bilinear redisribution on the detector grid, and detector residuals are transferred back to the object grid by the corresponding adjoint (transpose), implemented as bilinear interpolation, before applying an approximate FFT-diagonal preconditioner to accelerate convergence. The same framework supports polychromatic data through a compact spectral discretisation, allowing energy-dependent transport and inversion while keeping the iteration GPU/FFT efficient. Overall, this unified approach enables accurate and computationally efficient phase retrieval across propagation conditions relevant to high-throughput PPC-$μ$CT experiments.2026-01-30T10:15:23ZAlessandro MironeTheresa UrbanJoseph BrunetClaire L. WalshPeter D. LeePaul Tafforeauhttp://arxiv.org/abs/2601.22743v1Combining quasi-static and high frequency experiments for the viscoelastic characterization of brain tissue2026-01-30T09:23:03ZMechanical models of brain tissue are a beneficial tool to simulate neurosurgical interventions, disease progression, or brain development. However, the accuracy and predictive capacity of such a model relies on a precise experimental characterization of the tissue's mechanical behavior. Such a characterization is yet limited by inconsistent or contradictory experimental responses reported in the literature, particularly when measurements are performed in different time or length scales. Although brain tissue has been extensively investigated in previous studies, the combination of experimental findings from different scales has received limited attention. In this study, we combine ex vivo mechanical responses of porcine brain tissue obtained at different time scales in a mechanical model. We investigated the mechanical behavior of three different brain regions in the quasi-static domain with multi-modal large strain rheometer measurements and at high frequencies with magnetic resonance elastography (MRE). A comparative analysis of the mechanical parameters obtained from both experimental techniques demonstrated consistent regional variations in the viscoelastic behavior across the two domains. However, the mechanical behavior changes from a higher elasticity in the quasi-static and low frequency domain to a dominating viscosity at high frequencies. Based on the quasi-static and the high frequency behavior, we calibrated a fractional Kelvin-Voigt model and consequently unified the two responses in a single mechanical model to obtain a comprehensive characterization of the tissue's mechanical behavior.2026-01-30T09:23:03ZLaura RuhlandNina ReiterSilvia BuddayKai Willnerhttp://arxiv.org/abs/2510.21054v4Predictive Dosimetry in PSMA-Targeted Radiopharmaceutical Therapies: A PBPK Modeling and Machine Learning Study2026-01-29T23:04:02ZPredictive dosimetry is central to enabling personalized radiopharmaceutical therapy (RPT), particularly in prostate specific membrane antigen (PSMA) targeted theranostics. In this work, we develop a three layer computational framework that integrates physiologically based pharmacokinetic (PBPK) modeling with machine learning (ML) to predict both physical (AUC, absorbed dose) and biological (BED, EQD2) dosimetric endpoints in tumors and major organs. In the first layer, we generated 640 virtual patients using PBPK simulations of F-18, Ga-68, and Cu-64 labeled PSMA PET tracers paired with Lu-177 PSMA therapy, producing 15360 tumor and organ time activity curves (TACs) under realistic biological variability and PET-like noise. In the second layer, TACs were transformed into quantitative kinetic features and mapped to physical and biological dose metrics. In the third layer, ML models (Random Forest, Extra Trees, Ridge, Gradient Boosting, and XGBoost) were trained to predict RPT doses from PET derived features, with performance evaluated using mean absolute percentage error (MAPE) and R2. Cu-64 PSMA-617 based PET yielded the most robust predictions, achieving tumor dose MAPE as low as 8 percent and 10 to 20 percent for normal organs, while F-18 DCFPyL showed volume dependent performance and Ga-68 PSMA-11 exhibited higher variability. SHAP analysis revealed that peak uptake, clearance, and early kinetic features dominated predictive performance across organs and endpoints. This PBPK ML framework enables scalable, physiology informed predictive dosimetry and provides a foundation for trial design and patient specific treatment planning in PSMA targeted RPT. These results demonstrate that pre therapy PET can serve as a reliable surrogate for post therapy dosimetry, enabling scalable personalization of PSMA targeted RPT.2025-10-23T23:59:17ZHamid AbdollahiDepartment of Radiology, University of British Columbia, Vancouver, CanadaDepartment of Basic and Translation Research, BC Cancer Research institute, Vancouver, CanadaJames FowlerDepartment of Basic and Translation Research, BC Cancer Research institute, Vancouver, CanadaDepartment of Physics & Astronomy, University of British Columbia, Vancouver, CanadaCarlos UribeDepartment of Basic and Translation Research, BC Cancer Research institute, Vancouver, CanadaDepartment of Molecular Imaging and Therapy, BC Cancer, Vancouver, CanadaArman RahmimDepartment of Radiology, University of British Columbia, Vancouver, CanadaDepartment of Basic and Translation Research, BC Cancer Research institute, Vancouver, CanadaDepartment of Physics & Astronomy, University of British Columbia, Vancouver, Canadahttp://arxiv.org/abs/2601.22391v1Body Fat, Skin Tone, and the Accuracy of Smartwatch Caloric Expenditure Estimates2026-01-29T22:58:38ZSmartwatches are widely used to estimate caloric expenditure for weight management, clinical decision making, and public health monitoring. These devices combine photoplethysmography, accelerometry, and proprietary algorithms. However, prior studies report substantial error, and the influence of moderators such as skin tone and body fat percentage (BF) remains underexamined. This study tested whether smartwatch brand, BF, and Fitzpatrick skin type (III to V) predict caloric expenditure error relative to indirect calorimetry. Fifty eight Hispanic adults completed a single laboratory visit including a ten minute recumbent cycling protocol with alternating two minute moderate and vigorous intensity intervals, bracketed by rest and recovery. Participants wore four consumer devices: Apple Watch Series 8, Fitbit Sense 2, Samsung Galaxy Watch 5, and Garmin Forerunner 955. Energy expenditure was measured using a COSMED K5 metabolic system. After device specific data quality filtering, valid participant device pairings ranged from 44 to 52 per brand. One sample tests showed significant mean bias for three devices: Apple, Garmin, and Samsung. Fitbit showed no significant overall bias, although this depended on device specific outlier removal. Mean bias varied by brand, with Garmin and Samsung showing the largest overestimations. Mixed effects models revealed significant effects of device and BF, as well as a device by BF interaction, with physical activity energy expenditure error increasing as adiposity increased. Overall, common smartwatches substantially misestimate caloric expenditure compared with indirect calorimetry. Error varies by brand and worsens with higher body fat, highlighting limitations of current consumer wearables and the need for improved accuracy across diverse body types.2026-01-29T22:58:38ZJason KostrnaEkaterina OparinaAndres J. RodriguezJunZhu PeiAjmal AjmalCristina PalaciosJessica C. Ramella-Romanhttp://arxiv.org/abs/2601.22377v1PPG-Based Heart Rate Accuracy in Diverse Populations: Investigating Inequities Across Body Composition and Skin Tones2026-01-29T22:41:37ZWearable devices are widely used for heart rate (HR) monitoring, yet their accuracy across diverse body compositions and skin tones remains uncertain. This study evaluated four wrist worn devices (Apple, Fitbit, Samsung, Garmin) in 58 Hispanic adults with Fitzpatrick skin types III to V during a cycling protocol alternating moderate (0.64 to 0.76 HRmax) and vigorous (0.77 to 0.95 HRmax) intensities. Criterion HR was obtained using a Polar H10 ECG, and accuracy was assessed using mean absolute error, mean absolute percentage error (MAPE), bias, and intraclass correlation coefficients. All devices showed significant deviation from criterion measures. Apple and Garmin demonstrated the lowest error, whereas Fitbit and Samsung exhibited greater inaccuracies. Higher BMI and darker skin tones were associated with increased MAPE. These biases disproportionately affect higher risk populations, underscoring the need for improved algorithms to ensure equitable health monitoring.2026-01-29T22:41:37Z Kostrna Jason Oparina Ekaterina Palacios Cristina RodriguezAndres J Pei JunZhu Ajmal Ajmal Ramella-RomanJessica Chttp://arxiv.org/abs/2601.22059v1AIRPET: Virtual Positron Emission Tomography2026-01-29T17:58:27ZPositron Emission Tomography (PET) is a powerful medical imaging technique, but the design and evaluation of new PET scanner technologies present significant challenges. The process is typically divided into three major stages: 1. detector design and simulation, 2. image reconstruction, and 3. image interpretation. Each of these stages requires significant expertise, making it difficult for individuals or small teams to manage all three at once. AIRPET (AI-driven Revolution in Positron Emission Tomography) is a web-based platform designed to address this challenge by integrating all phases of PET design into a single, accessible, and AI-assisted workflow. AIRPET provides an interface to large language models (LLMs) for assisted geometry creation and an interface for basic PET image reconstruction with the potential for further expansion. Here we introduce AIRPET and outline its current functionality and proposed additions.2026-01-29T17:58:27Z6 pages, 3 figuresJ. RennerJ. J. Gómez-CadenasR. Soletihttp://arxiv.org/abs/2312.15462v2DeLTA-BIT: an open-source probabilistic tractography-based deep learning framework for thalamic targeting in functional neurological disorders2026-01-29T12:19:02ZIn the last years in-vivo tractography has assumed an important role in neurosciences, for both research and clinical applications such as non-invasive investigation of brain connectivity and presurgical planning in neurosurgery. In more recent years there has been a growing interest in the applications of diffusion tractography for target identification in functional neurological disorders for an increasingly tailored approach. The growing diffusion of well-established neurosurgical procedures, such as deep brain stimulation or trans-cranial Magnetic Resonance-guided Focused Ultrasound, favored this trend. Tractography can indeed provide more accurate, patient-specific, information about the targeted region if compared to stereotactic atlases. On the other hand, this tractography-based approach is not very physician-friendly, and its heavily time consuming since it needs several hours for Magnetic Resonance Imaging data processing. In this study we propose a novel open-source deep learning framework called DeLTA-BIT (acronym of Deep-learning Local TrActography for BraIn Targeting) for fast target predictions, based on probabilistic tractography. The proposed framework exploits a convolutional neural network (CNN) to predict the location of the Ventral Intermediate Nucleus of the thalamus (VIM). The CNN was trained on the Human Connectome Project (HCP) dataset. The model capability in predicting the VIM location was tested both on the HCP (internal validation) and clinical data (external validation). Results from the internal validation have shown good capability in predicting the VIM region (mean DSC = 0.62+- 0.15, mean sDSC=0.76+- 0.17) by using just T1 images as input, in a time scale of fraction of second per subject. As for the clinical data, results have been compared with an atlas-based method demonstrating similar performance, but within a significantly shorter timeframe.2023-12-24T11:43:36ZMattia RomeoCesare GagliardoGrazia CottoneGiorgio ColluraEnrico MaggioClaudio RunfolaEleonora BrunoMaria Cristina D'OcaMassimo MidiriFrancesca LizziIan PostumaMarco D'AmelioAlessandro LascialfariAlessandra ReticoMaurizio Marralehttp://arxiv.org/abs/2602.00146v1Effects of PLGA coating on biological and mechanical behaviors of tissue engineering scaffolds2026-01-29T08:30:16ZScaffolds have a key role in the clinical success of tissue engineering for the regeneration of damaged tissues. Their bio-performance is often described as the extent to which they can provide an extracellular matrix-like environment for cells embedded where their function and growth can effectively continue. For this purpose, tissue engineering scaffolds should exhibit biodegradability, biocompatibility, bioactivity, delivery, and mechanical performance. The use of polymer coatings, especially poly(lactic-co-glycolic acid) (PLGA), on tissue engineering scaffolds has been found to be one of the most effective methods to improve the scaffold properties. This paper reviews the techniques used to coat tissue engineering scaffolds with PLGA and its effects on the mechanical characteristics, biodegradability, biocompatibility, Molecular delivery, and osteointegration of the scaffolds. It is concluded that apart from apatite-formation ability, all bio-functionalities can be tuned through PLGA coatings. This reflects the great potential of this modification approach to be used in tissue regeneration and therapeutic delivery applications.2026-01-29T08:30:16ZProgress in Organic Coatings, 176 (2023) 107406A. M. MaadaniF. DavoodianE. Salahinejad10.1016/j.porgcoat.2023.107406http://arxiv.org/abs/2602.07003v1Time-Resolved Multi-Spectral X-ray Computed Tomography of Cryoprotectant Diffusion Into Biomimetic Material2026-01-29T04:59:02ZCryopreservation via vitrification requires loading cryoprotective cocktails. Insufficient loading may lead to freezing, precluding successful recovery; overloading is toxic. Yet, existing in situ measurements of cryoprotectant permeation remain largely unvalidated and do not resolve individual cryoprotectant concentrations. We introduce multi-spectral X-ray computed tomography (MSCT) to noninvasively quantify the spatiotemporal distribution of cryoprotectants diffusing into a tissue mimicking phantom. A developed photon-energy bin selection algorithm achieves sensitivity to low contrast cryoprotectants without contrast agents or fluorescence edges. The technique is validated with a dimethyl sulfoxide, glycerol, and water solution, resolving cryoprotectant volume fractions to within 5% accuracy. We observe heterogeneous diffusion of the cryoprotectants into the tissue mimicking hydrogel, a phenomenon not observable with conventional techniques. MSCT improves upon existing X ray CT methods because it is not underdetermined for multicomponent solutions and does not implicitly assume homogeneous diffusion. These advancements enable the systematic development of cryoprotectant loading protocols and provide diagnostics to assess vitrifiability before cryopreservation.2026-01-29T04:59:02Z30 pages, 10 figuresAlaa M. AliJason T. ParkerAnthony N. ConsiglioBrooke S. ChangLinnea WarburtonBoris RubinskySimo A. Mäkiharjuhttp://arxiv.org/abs/2601.20549v1Multicenter Comparison of Radionuclide Calibrators and SPECT/CT Protocols for Quantitative 177Lu Imaging in Clinical Practice2026-01-28T12:45:04ZPurpose: Following the clinical success of 177Lu-based therapies for neuroendocrine tumors and prostate cancer, accurate quantification of 177Lu using radionuclide calibrators (RNCs) and 177Lu-SPECT/CT is gaining importance as prerequisite for accurate treatment delivery and dosimetry. However, the lack of standardization can introduce inter-system variability, compromising multi-center clinical trials. This study aimed to assess the accuracy and variability of 177Lu measurements using RNCs and SPECT/CT across different systems and hospitals. Methods: A uniform cylindrical phantom and a NEMA phantom with hot spheres were prepared using traceable activities and imaged at 8 different hospitals using 13 SPECT/CT systems (9 conventional and 4 3D CZT). Acquisitions and reconstructions were performed using both site-specific and standardized protocols. The cylindrical phantom images were used to establish image calibration factors (ICFs), the NEMA images to evaluate image quality by calculating recovery coefficients (RCs). Both were used to evaluate quantitative SPECT accuracy. In parallel, two vials were measured to test RNC accuracy. Results: RNC measurements differed up to 11% between centers, while SPECT quantification differed up to 20% and 58% for the cylindrical and NEMA phantoms respectively. While ICFs were consistent for systems of the same type, image quality varied strongly when using clinical protocols. Standardized reconstruction reduced variability for each system type, regardless of acquisition protocol, but differences between system types persisted when harmonizing acquisition and reconstruction. Conclusion: Current 177Lu measurement practices yield significant variability in quantification and image quality. Harmonization efforts should prioritize standardized calibration and reconstruction protocols to improve multicenter reproducibility of quantitative 177Lu-SPECT/CT.2026-01-28T12:45:04Z36 pages, 18 figuresWies ClaeysKristof BaeteLaurence BeelsClaire BernardRachele DanieliYves D' AsselerAn De CropMichel HesseVictor NuttensBruno VanderlindenMichel Koole