https://arxiv.org/api/1xNNO2vr71UlSW/0+YM5SQqKZ60 2026-06-21T19:51:42Z 8985 225 15 http://arxiv.org/abs/2604.12778v1 DoseRAD2026 Challenge dataset: AI accelerated photon and proton dose calculation for radiotherapy 2026-04-14T14:16:45Z Purpose: Accurate dose calculation is essential in radiotherapy for precise tumor irradiation while sparing healthy tissue. With the growing adoption of MRI-guided and real-time adaptive radiotherapy, fast and accurate dose calculation on CT and MRI is increasingly needed. The DoseRAD2026 dataset and challenge provide a public benchmark of paired CT and MRI data with beam-level photon and proton Monte Carlo dose distributions for developing and evaluating advanced dose calculation methods. Acquisition and validation methods: The dataset comprises paired CT and MRI from 115 patients (75 training, 40 testing) treated on an MRI-linac for thoracic or abdominal lesions, derived from the SynthRAD2025 dataset. Pre-processing included deformable image registration, air-cavity correction, and resampling. Ground-truth photon (6 MV) and proton dose distributions were computed using open-source Monte Carlo algorithms, yielding 40,500 photon beams and 81,000 proton beamlets. Data format and usage notes: Data are organized into photon and proton subsets with paired CT-MRI images, beam-level dose distributions, and JSON beam configuration files. Files are provided in compressed MetaImage (.mha) format. The dataset is released under CC BY-NC 4.0, with training data available from April 2026 and the test set withheld until March 2030. Potential applications: The dataset supports benchmarking of fast dose calculation methods, including beam-level dose estimation for photon and proton therapy, MRI-based dose calculation in MRI-guided workflows, and real-time adaptive radiotherapy. 2026-04-14T14:16:45Z Fan Xiao Nikolaos Delopoulos Niklas Wahl Lennart Volz Lina Bucher Matteo Maspero Miguel Palacios Muheng Li Samir Schulz Viktor Rogowski Ye Zhang Zoltan Perko Christopher Kurz George Dedes Guillaume Landry Adrian Thummerer http://arxiv.org/abs/2604.11776v1 Bicuspid Valve Closure and Backflow Prevention: Role of Leaflet Geometry 2026-04-13T17:44:04Z Bicuspid valves with crescent-shaped leaflets are found in lymphatic vessels and veins, where their primary function is to prevent reflux and ensure unidirectional flow toward the heart. These valves are passive, and their functionality emerges spontaneously from a complex interplay between the properties of the valve leaflets and the flow patterns developing within the vessel sinus region surrounding the valve. The main function of the valves is to limit retrograde flow, or reflux, but the optimal valve structure has not been well-characterized. Here we investigate numerically how the length of the leaflets affects the valve efficiency in preventing reflux. The valves are subjected to backward flow, akin to that imposed by gravity. We report the flux through the valve orifice as a function of key parameters: valve length, leaflet length, and leaflet rigidity. We monitor the transition in the flow regime - from reflux to complete flow blockage - by varying only the leaflet length. The transition threshold is found to depend strongly on the valve shape and stiffness. We captured these control parameters numerically to evaluate the ability of the valve to close and prevent reflux. This study allowed us to explain reflux observed experimentally in certain incompetent abnormal and immature valves, particularly those with shorter leaflets. 2026-04-13T17:44:04Z 13 pages, 9 figures Phys. Rev. Fluids 11, 033103 (2026) B. Kaoui A. Bou Orm P. Navet J. Baish L. L. Munn 10.1103/bxwj-qlxf http://arxiv.org/abs/2604.11762v1 MosaicMRI: A Diverse Dataset and Benchmark for Raw Musculoskeletal MRI 2026-04-13T17:36:01Z Deep learning underpins a wide range of applications in MRI, including reconstruction, artifact removal, and segmentation. However, progress has been driven largely by public datasets focused on brain and knee imaging, shaping how models are trained and evaluated. As a result, careful studies of the reliability of these models across diverse anatomical settings remain limited. In this work, we introduce MosaicMRI, a large and diverse collection of fully sampled raw musculoskeletal (MSK) MR measurements designed for training and evaluating machine-learning-based methods. MosaicMRI is the largest open-source raw MSK MRI dataset to date, comprising 2,671 volumes and 80,156 slices. The dataset offers substantial diversity in volume orientation (e.g., axial, sagittal), imaging contrasts (e.g., PD, T1, T2), anatomies (e.g., spine, knee, hip, ankle, and others), and numbers of acquisition coils. Using VarNet as a baseline for accelerated reconstruction task, we perform a comprehensive set of experiments to study scaling behavior with respect to both model capacity and dataset size. Interestingly, models trained on the combined anatomies significantly outperform anatomy-specific models in low-sample regimes, highlighting the benefits of anatomical diversity and the presence of exploitable cross-anatomical correlations. We further evaluate robustness and cross-anatomy generalization by training models on one anatomy (e.g., spine) and testing them on another (e.g., knee). Notably, we identify groups of body parts (e.g., foot and elbow) that generalize well with each other, and highlight that performance under domain shifts depends on both training set size, anatomy, and protocol-specific factors. 2026-04-13T17:36:01Z 15 pages, 6 figures, preliminary version Paula Arguello Berk Tinaz Mohammad Shahab Sepehri Maryam Soltanolkotabi Mahdi Soltanolkotabi http://arxiv.org/abs/2509.22736v2 PnP-CM: Consistency Models as Plug-and-Play Priors for Inverse Problems 2026-04-13T17:31:52Z Diffusion models have found extensive use in solving inverse problems, by sampling from an approximate posterior distribution of data given the measurements. Recently, consistency models (CMs) have been proposed to directly predict the final output from any point on the diffusion ODE trajectory, enabling high-quality sampling in just a few neural function evaluations (NFEs). CMs have also been utilized for inverse problems, but existing CM-based solvers either require additional task-specific training or utilize data fidelity operations with slow convergence, limiting their applicability to large-scale problems and making them difficult to extend to nonlinear settings. In this work, we reinterpret CMs as proximal operators of a prior, enabling their integration into plug-and-play (PnP) frameworks. Specifically, we propose PnP-CM, an ADMM-based PnP solver that provides a unified framework for solving a wide range of inverse problems, and incorporates noise perturbations and momentum-based updates to improve performance in the low-NFE regime. We evaluate our approach on a diverse set of linear and nonlinear inverse problems. We also train and apply CMs to MRI data for the first time. Our results show that PnP-CM achieves high-quality reconstructions in as few as 4 NFEs, and produces meaningful results in 2 steps, highlighting its effectiveness in real-world inverse problems while outperforming existing CM-based approaches. 2025-09-25T20:27:56Z IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 2026 Merve Gülle Junno Yun Yaşar Utku Alçalar Mehmet Akçakaya http://arxiv.org/abs/2601.14970v2 Beyond directions: Symmetry-aware rotation sets for triaxial diffusion encoding by geometric filter optimization 2026-04-13T16:19:35Z Purpose: To improve the accuracy of diffusion-weighted powder average signals for diffusion encoding with arbitrary b-tensors. Methods: We identify an intrinsic dihedral ($D_2$) symmetry of diffusion signals for arbitrary diffusion encoding, which defines their natural signal space (a quotient of 3D rotations). Based on this, we propose a method to generate optimal rotation sets that are applied to the diffusion-encoding gradient waveform to yield powder averages with maximal accuracy. The method, termed ``Geometric Filter Optimization'' (GFO), amounts to designing a sampling filter that is approximately flat over the relevant part of the associated frequency space. We characterize the filter properties and benchmark performance in terms of the accuracy and precision of powder averages and higher-order rotational invariants, including comparison with spherical designs and electrostatic-repulsion-based designs defined on the same space. Results: We found that GFO leads to marked improvements in precision and accuracy in powder averaging over diffusion encoding b-tensors, including axisymmetric and triaxial configurations. For higher-order rotational invariants, the performance was more nuanced, with GFO, electrostatic repulsion, and spherical designs exhibiting different trade-offs in bias and precision depending on $b$ and $N$. Conclusion: A fundamental $D_2$-symmetry of tensor-valued diffusion encoding was shown to constrain its rotational structure and guide the design of optimal rotation sets. This yielded GFO, which provides an efficient recipe for obtaining orientations for powder averaging of signals with axisymmetric and triaxial diffusion encoding. It places no additional demands on gradient system performance and can be used to shorten scan time. 2026-01-21T13:19:50Z 25 pages, 8 figures Sune Nørhøj Jespersen Filip Szczepankiewicz http://arxiv.org/abs/2604.11559v1 Progressively Texture-Aware Diffusion for Contrast-Enhanced Sparse-View CT 2026-04-13T14:45:09Z Diffusion-based sparse-view CT (SVCT) imaging has achieved remarkable advancements in recent years, thanks to its more stable generative capability. However, recovering reliable image content and visually consistent textures is still a crucial challenge. In this paper, we present a Progressively Texture-aware Diffusion (PTD) model, a coarse-to-fine learning framework tailored for SVCT. Specifically, PTD comprises a basic reconstructive module PTD$_{\textit{rec}}$ and a conditional diffusion module PTD$_{\textit{diff}}$. PTD$_{\textit{rec}}$ first learns a deterministic mapping to recover the majority of the underlying low-frequency signals (i.e., coarse content with smoothed textures), which serves as the initial estimation to enable fidelity. Moreover, PTD$_{\textit{diff}}$ aims to reconstruct high-fidelity details for coarse prediction, which explores a dual-domain guided conditional diffusion to generate reliable and consistent textures. Extensive experiments on sparse-view CT reconstruction demonstrate that our PTD achieves superior performance in terms of structure similarity and visual appeal with only a few sampling steps, which mitigates the randomness inherent in general diffusion models and enables a better trade-off between visual quality and fidelity of high-frequency details. 2026-04-13T14:45:09Z ICASSP2026 Tianqi Wang Wenchao Du Hongyu Yang http://arxiv.org/abs/2604.09804v1 A Conjugate Bayesian Framework for Fast 3D Positronium Lifetime Estimation with a Partial System Matrix 2026-04-10T18:26:02Z Background: Positronium lifetime imaging extends conventional positron emission tomography by using the time interval between positron emission and annihilation as an additional contrast mechanism. Voxel-wise lifetime estimation in fully three-dimensional settings is computationally difficult because the number of feasible detector-time channels grows rapidly, whereas only a small subset is observed in practice. We developed a scalable statistical framework for three-dimensional positronium lifetime estimation based on a time-of-flight-aware partial system matrix restricted to observed detector-time channels, combined with posterior event-to-voxel weighting and a conjugate Gamma--Exponential update for closed-form voxel-wise effective-rate estimation. Results: Restricting the forward model to observed detector-time channels reduced memory and computational requirements while preserving the Poisson data model for retained detected triple coincidences. In simulated data with 4056 voxels, the analytic Bayesian estimator required 2.76 s versus 74.46 s for 10 L-BFGS-B iterations on the same CPU while accurately recovering the effective-rate map. In a triple-coincidence dataset acquired with a J-PET prototype scanner and a NEMA image-quality phantom, a 234 375-voxel effective-rate map was estimated in approximately 3 s from about $3.64\times10^5$ retained events. Conclusions: Restricting the system matrix to observed detector-time channels makes fully three-dimensional positronium lifetime estimation computationally practical for sparse triple-coincidence data. The proposed posterior-weighted conjugate update provides a fast and stable single-component surrogate estimator of voxel-wise effective lifetime for large-scale three-dimensional positronium lifetime imaging. 2026-04-10T18:26:02Z Berkin Uluutku Giulianno Gasparato Manish Das Jarosław Choiński Anand Pandey Sushil Sharma Paweł Moskal Ewa Stępień Chien-Min Kao Hsin-Hsiung Huang http://arxiv.org/abs/2510.24879v2 General Microstructure Factor Analysis of Diffusion MRI in Gray-Matter Predicts Cognitive Scores 2026-04-10T15:30:04Z Diffusion magnetic resonance imaging (MRI) has revealed important insights into white matter microstructure, but its application to gray matter remains comparatively less explored. Here, we investigate whether global patterns of gray-matter microstructure can be captured through neurite orientation dispersion and density imaging (NODDI) and whether such patterns are predictive of cognitive performance. Using diffusion MRI and behavioral data from the Human Connectome Project Young Adult study, we derive region averaged NODDI parameters and apply principal component analysis (PCA) to construct general gray-matter microstructure factors. We find that the factor derived from isotropic volume fraction explained substantial inter-individual variability and was significantly correlated with specific cognitive scores collected from the NIH Toolbox. In particular, the isotropic volume fraction factor is linked to reading and vocabulary performance and to cognitive fluidity. Our findings demonstrate that PCA-based global indicators of gray-matter microstructure provide complementary markers of structure-function relationships, extending beyond region-specific analyses. Our results suggest that general microstructure factors may serve as population-level exploratory biomarkers for studying cognition and cortical organization. 2025-10-28T18:28:00Z 11 pages, 5 figures, 1 table Lucas Z. Brito Ryan P. Cabeen David H. Laidlaw http://arxiv.org/abs/2505.01206v2 Design for a Digital Twin in Clinical Patient Care 2026-04-09T22:09:28Z Digital Twins hold great potential to personalize clinical patient care, provided the concept is translated to meet specific requirements emerging from established clinical workflows. We present a general and unspecialized Digital Twin design combining knowledge graphs and ensemble learning to reflect the entire patient's clinical journey and assist clinicians in their decision-making. Such a design is predictive, modular, evolving, informed, interpretable and explainable, thus opening broad clinical applications. 2025-05-02T11:50:42Z Accepted version of the journal. Added clinical examples in the supplementary material and revised the introduction and section 3 Anna-Katharina Nitschke Physikalisches Institut, Universität Heidelberg, Heidelberg, Germany Carlos Brandl Physikalisches Institut, Universität Heidelberg, Heidelberg, Germany Fabian Egersdörfer Physikalisches Institut, Universität Heidelberg, Heidelberg, Germany Magdalena Görtz Junior Clinical Cooperation Unit 'Multiparametric Methods for Early Detection of Prostate Cancer', German Cancer Research Center Department of Urology, Heidelberg University Hospital, Heidelberg, Germany Markus Hohenfellner Department of Urology, Heidelberg University Hospital, Heidelberg, Germany Matthias Weidemüller Physikalisches Institut, Universität Heidelberg, Heidelberg, Germany 10.1038/s44401-025-00060-1 http://arxiv.org/abs/2604.08781v1 PSIRNet: Deep Learning-based Free-breathing Rapid Acquisition Late Enhancement Imaging 2026-04-09T21:31:48Z Purpose: To develop and evaluate a deep learning (DL) method for free-breathing phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiac MRI that produces diagnostic-quality images from a single acquisition over two heartbeats, eliminating the need for 8 to 24 motion-corrected (MOCO) signal averages. Materials and Methods: Raw data comprising 800,653 slices from 55,917 patients, acquired on 1.5T and 3T scanners across multiple sites from 2016 to 2024, were used in this retrospective study. Data were split by patient: 640,000 slices (42,822 patients) for training and the remainder for validation and testing, without overlap. The training and testing data were from different institutions. PSIRNet, a physics-guided DL network with 845 million parameters, was trained end-to-end to reconstruct PSIR images with surface coil correction from a single interleaved IR/PD acquisition over two heartbeats. Reconstruction quality was evaluated using SSIM, PSNR, and NRMSE against MOCO PSIR references. Two expert cardiologists performed an independent qualitative assessment, scoring image quality on a 5-point Likert scale across bright blood, dark blood, and wideband LGE variants. Paired superiority and equivalence (margin = 0.25 Likert points) were tested using exact Wilcoxon signed-rank tests at a significance level of 0.05 using R version 4.5.2. Results: Both readers rated single-average PSIRNet reconstructions superior to MOCO PSIR for dark blood LGE (conservative P = .002); for bright blood and wideband, one reader rated it superior and the other confirmed equivalence (all P < .001). Inference required approximately 100 msec per slice versus more than 5 sec for MOCO PSIR. Conclusion: PSIRNet produces diagnostic-quality free-breathing PSIR LGE images from a single acquisition, enabling 8- to 24-fold reduction in acquisition time. 2026-04-09T21:31:48Z 25 pages, 5 figures, 4 tables Arda Atalik Hui Xue Rhodri H. Davies Thomas A. Treibel Daniel K. Sodickson Michael S. Hansen Peter Kellman http://arxiv.org/abs/2604.08092v1 Predicting Mesoscopic Larmor Frequency Shifts in Ex Vivo Porcine Optic Nerve 2026-04-09T11:08:07Z Larmor frequency shifts in white matter (WM) vary with fiber orientation due to anisotropic microstructure. Since clinical voxels are significantly larger than these microscopic frequency variations, the measured signal represents a bulk average of local shifts. Accurate estimation of magnetic susceptibility therefore requires accounting for these underlying frequency distributions that exist below the imaging resolution. We evaluated whether Microstructure-informed Quantitative Susceptibility Mapping (μQSM) can predict orientation-dependent sub-voxel frequency shifts from orientationally dispersed hollow cylinders and spherical inclusions. Diffusion-weighted and multi-gradient-echo images were acquired from ex vivo pig optic nerves at multiple orientations relative to the main magnetic field using a 3T Siemens Connectom scanner. We also analyzed de-ironed optic nerves to try and separate the effects of myelin and iron on susceptibility. The estimated sub-voxel frequency shifts closely matched μQSM predictions, consistent with mesoscopic field perturbations generated by uniformly magnetized axons. De-ironing had minimal effect on the frequency shifts, indicating negligible iron contribution. μQSM accurately reproduces the orientation dependence of Larmor frequency shifts in optic nerve WM, providing new insight into their microstructural origin and supporting improved estimation of tissue magnetic susceptibility in Quantitative Susceptibility Mapping. 2026-04-09T11:08:07Z Anders Dyhr Sandgaard André Pampel Roland Müller Niklas Wallstein Toralf Mildner Carsten Jäger Markus Morawski Aage Kristian Olsen Alstrup Harald E. Möller Sune Nørhøj Jespersen http://arxiv.org/abs/2604.06992v1 Statistical Analysis of the Reliability of Data Collected with Wireless Electrocardiograms Outside Clinical Settings 2026-04-08T12:07:38Z Cost-effective wireless electrocardiograms (ECGs) enable long-term and scalable monitoring of cardiac patients in their home and work environments. Because they offer greater freedom of movement, they are also suitable for investigating the relationship between cardiac workload and underlying physical exertion. However, this requires that the quality of the generated data meets the standards of clinical devices. The aim of this study is to examine this closely. We therefore analyze data from 54 healthy subjects who performed five physical activities using wireless ECGs outside of clinical settings and without medical supervision. The results are compared with clinically collected data from standard 12-lead ECGs (2493 subjects) and Holter ECGs (29 subjects), with particular attention to the RR interval time series (tachogram) and heart rate variability (HRV). Our study shows significant statistical agreement between the different datasets. We calculated the 95% confidence intervals for the mean RR interval and HRV assuming that (1) the statistics of the 12-lead ECGs could serve as reliable reference, and (2) the statistics of the 12-lead ECGs cannot be taken as reliable reference. The p-values for both conditions (for the RR interval: 0.23 and 0.26 respectively; for HRV: 0.10 and 0.11 respectively) suggest that there is insufficient evidence to reject the hypothesis that significant statistical agreement exists between the different datasets. 2026-04-08T12:07:38Z Yalemzerf Getnet Waltenegus Dargie http://arxiv.org/abs/2604.06671v1 4D Vessel Reconstruction for Benchtop Thrombectomy Analysis 2026-04-08T04:45:17Z Introduction: Mechanical thrombectomy can cause vessel deformation and procedure-related injury. Benchtop models are widely used for device testing, but time-resolved, full-field 3D vessel-motion measurements remain limited. Methods: We developed a nine-camera, low-cost multi-view workflow for benchtop thrombectomy in silicone middle cerebral artery phantoms (2160p, 20 fps). Multi-view videos were calibrated, segmented, and reconstructed with 4D Gaussian Splatting. Reconstructed point clouds were converted to fixed-connectivity edge graphs for region-of-interest (ROI) displacement tracking and a relative surface-based stress proxy. Stress-proxy values were derived from edge stretch using a Neo-Hookean mapping and reported as comparative surface metrics. A synthetic Blender pipeline with known deformation provided geometric and temporal validation. Results: In synthetic bulk translation, the stress proxy remained near zero for most edges (median $\approx$ 0 MPa; 90th percentile 0.028 MPa), with sparse outliers. In synthetic pulling (1-5 mm), reconstruction showed close geometric and temporal agreement with ground truth, with symmetric Chamfer distance of 1.714-1.815 mm and precision of 0.964-0.972 at $τ= 1$ mm. In preliminary benchtop comparative trials (one trial per condition), cervical aspiration catheter placement showed higher max-median ROI displacement and stress-proxy values than internal carotid artery terminus placement. Conclusion: The proposed protocol provides standardized, time-resolved surface kinematics and comparative relative displacement and stress proxy measurements for thrombectomy benchtop studies. The framework supports condition-to-condition comparisons and methods validation, while remaining distinct from absolute wall-stress estimation. Implementation code and example data are available at https://ethanuser.github.io/vessel4D 2026-04-08T04:45:17Z 20 pages, 10 figures, 1 table, supplementary material (3 tables, 3 figures, and 11 videos). Project page: https://ethanuser.github.io/vessel4D/ Ethan Nguyen Javier Carmona Arisa Matsuzaki Naoki Kaneko Katsushi Arisaka http://arxiv.org/abs/2604.06649v1 Bayesian Aneurysm Growth Detection via Surface Displacement Modeling 2026-04-08T03:52:39Z Clinical decisions for unruptured intracranial aneurysms depend on detecting growth on follow-up magnetic resonance angiography (MRA). Growth is typically judged from manual 2D diameters on few slices, which vary across clinicians and frequently miss subtle 3D change. Even with 3D segmentations, apparent differences can reflect resolution, segmentation, surface processing, or registration mismatch rather than true growth; most criteria remain heuristic and binary. We show that a Bayesian displacement-based model using the surrounding vessel as an internal reference achieves strong discrimination of aneurysm growth (AUC 0.86-0.87) and improves agreement with expert labels (Cohen's kappa up to 0.66 vs. 0.35 for volumetric criteria), while providing calibrated posterior probabilities with uncertainty bounds. The method registers baseline and follow-up surfaces, computes normal-directed displacements, and summarizes change as the difference between mean aneurysm displacement and mean displacement on the surrounding non-aneurysmal vessel segment. The vessel segment serves as an internal control for imaging and processing variability, assuming negligible structural change over the surveillance interval. We evaluate two cohorts spanning time-of-flight and contrast-enhanced longitudinal MRA studies: a public dataset labeled from neuroradiologist-provided measurements and an institutional dataset labeled by senior and junior raters. Performance is preserved when training on lower-expertise labels, indicating robustness to label variability. Calibrated probabilities may aid clinical decision-making in borderline cases, where high uncertainty can motivate repeat imaging. This framework provides interpretable probabilistic growth assessment from longitudinal MRA, reduces dependence on clinician expertise, and supports cross-center surveillance across scanners and angiography sequences. 2026-04-08T03:52:39Z Jorge A. Roa Castro Abhishek Singh Atharva Hans Kostiantyn Kondratiuk David Saloner Vitaliy L. Rayz Pavlos P. Vlachos Ilias Bilionis http://arxiv.org/abs/2412.04706v2 Comparison of Deep Learning and Particle Smoother EM Methods for Estimation of Rb-82 Myocardial Perfusion PET Kinetic Parameters 2026-04-07T22:40:52Z Positron emission tomography (PET) enables quantification of dynamic physiological processes through time-resolved imaging. In Rb-82 myocardial perfusion PET, kinetic compartment modeling is used to estimate physiological parameters and derive myocardial blood flow. However, conventional nonlinear least squares (NLLS) estimation is sensitive to model misspecification when not all parameters can be reliably estimated and must instead be fixed or initialized using population averages, which can degrade accuracy. This work develops and evaluates two alternative kinetic analysis approaches for Rb-82 PET: a particle smoother-based Expectation-Maximization method (PSEM) and a convolutional neural network (CNN). Both methods were evaluated using simulated Rb-82 dynamic myocardial perfusion studies and compared against NLLS and a Kalman smoother-based Expectation-Maximization (KEM) algorithm across multiple frame durations and noise levels. Across 2-10 s frames, the CNN achieved the lowest relative errors for all parameters (F: 8.78-4.98%, k3: 26.05-25.50%, k4: 34.34-22.76%), significantly outperforming NLLS, KEM, and PSEM (Holm-adjusted p < 1e-15 at 1.0x noise, 2 s frames), although performance degraded under out-of-distribution input-function conditions. Overall, the CNN provided the most accurate and robust in-distribution kinetic parameter estimates across frame durations. In contrast, PSEM exhibited parameter-dependent behavior, improving k3 estimation while underperforming for F, suggesting that further methodological refinement is needed. 2024-12-06T01:39:10Z 40 pages, 9 figures. Tentatively accepted to Medical Physics Myungheon Chin Sarah J Zou Garry Chinn Craig S. Levin