https://arxiv.org/api/22+GLYRikk6rXlQ0m5m1epksBK0 2026-06-21T18:34:59Z 8985 210 15 http://arxiv.org/abs/2509.07971v2 Cardiac mechanics modeling: recent developments and current challenges 2026-04-17T21:03:00Z Patient-specific computational models of the heart are powerful tools for cardiovascular research and medicine, with demonstrated applications in treatment planning, device evaluation, and surgical decision-making. Yet constructing such models is inherently difficult, reflecting the extraordinary complexity of the heart itself. Numerous considerations are required, including reconstructing the anatomy from medical images, representing myocardial mesostructure, capturing material behavior, defining model geometry and boundary conditions, coupling multiple physics, and selecting numerical methods. Many of these choices involve a tradeoff between physiological fidelity and modeling complexity. In this review, we summarize recent advances and unresolved questions in each of these areas, with particular emphasis on cardiac tissue mechanics. We argue that clarifying which complexities are essential, and which can be safely simplified, will be key to enabling clinical translation of these models. 2025-09-09T17:55:56Z Changed license to non-exclusive. Fixed typos in references Aaron L. Brown Ju Liu Daniel B. Ennis Alison L. Marsden http://arxiv.org/abs/2604.16131v1 Prompt Gamma Timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations 2026-04-17T15:06:14Z Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. This study investigates for the first time the application of PGT in carbon ion therapy. Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) read out by a SiPM for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO. The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. A bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Photons were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. The validated experimental-simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy. 2026-04-17T15:06:14Z This work has been submitted to Physics in Medicine and Biology on February 2, 2026 Iram Barbaro Rivas Ortiz Sahar Ranjbar Piergiorgio Cerello Emanuele Maria Data Mohammad Fadavi Mazinani Miguel David Fernandez Moreira Veronica Ferrero Simona Giordanengo Felix Mas Milian Diango Manuel Montalvan Olivares Francesco Pennazio Marco Pullia Roberto Sacchi Roberto Cirio Simone Savazzi Anna Vignati Elisa Fiorina http://arxiv.org/abs/2602.22535v2 Evaluating the resolution of AI-based accelerated MR reconstruction using a deep learning-based model observer 2026-04-17T04:34:01Z We developed a deep learning-based model observer (DLMO) to evaluate a multi-coil sensitivity encoding parallel MRI system at different accelerations on the Rayleigh discrimination task as a surrogate measure of resolution. We inserted Gaussian-convolved doublet and singlet signals into the white matter area of synthetic brain images. K-space raw data were acquired by using a simulated MR imaging system at acceleration factors of one (fully sampled), four and eight. These raw data were reconstructed using a conventional root-sum-of-squares (rSOS) method and an U-Net method. DLMOs were first trained with fully sampled images and then re-trained for each acceleration using a transfer learning approach. These DLMOs had a similar discrimination performance as trained human readers, using a human-label alignment training strategy. The resolution of rSOS- and U-Net-reconstructed images was assessed using the area under the receiver operating characteristic curve (AUC). We observed that the U-Net method yielded significantly higher PSNR and SSIM than rSOS across different accelerations. However, task-based evaluation using the proposed DLMO revealed that the U-Net underperformed relative to the fully sampled reconstruction (i.e. rSOS 1x). Although U-Net at an acceleration factor of four exhibited modest gains over rSOS at the same acceleration for short signals, its AUC decreased by approximately 25% and 5% for 4 mm and 5 mm signals, respectively, compared with rSOS 1x. Comparable declines in U-Net-obtained AUC relative to rSOS 1x were also observed at acceleration factor of eight. These results demonstrate that AI-based accelerated MR reconstruction may produce visually pleasing images but may not achieve performance comparable to that of rSOS 1x. The proposed DLMO approach may be employed to characterize the discriminative efficacy of AI-based undersampled reconstruction in MRI. 2026-02-26T02:15:12Z Zitong Yu Rongping Zeng Frank Samuelson Prabhat Kc http://arxiv.org/abs/2604.15478v1 Fractal geometry-governed oxygen diffusion: Tumors vs. Normal Tissues 2026-04-16T19:03:31Z {\bf Purpose}: To develop a geometry-governed diffusion framework that explains differential tissue response under FLASH ultra-high dose rate (UHDR) irradiation by explicitly accounting for structural heterogeneity and anomalous transport in biological tissues. {\bf Methods}: We formulate a generalized diffusion--reaction model on fractal substrates to describe molecular transport in heterogeneous media. Tissue architecture is characterized by a fractal (Hausdorff) dimension \(D\), while scale-dependent transport inefficiency and memory effects are captured by a fractional parameter \(θ\). Analytical solutions for radially symmetric geometries are derived and compared with classical normal (Euclidean) diffusion and a Gaussian reference model under identical physical conditions. Transport behavior is quantified through transient probability distributions and steady-state spatial profiles. {\bf Results}: The model reveals systematic suppression of long-range transport and enhanced localization as tissue structural complexity increases. Increasing \(θ\) leads to subdiffusive dynamics, reduced effective diffusion lengths, and persistent non-Gaussian concentration profiles, even in the steady state. While increasing \(D\) alone enhances spatial accessibility, fractional dynamics dominate transport behavior when \(θ>0\), counteracting geometric connectivity. These effects produce a separation between regimes characterized by efficient inter-track overlap and rapid homogenization, and regimes marked by isolated, long-lived reactive domains. 2026-04-16T19:03:31Z Neda Valizadeh Robabeh Rahimi Ramin Abolfath http://arxiv.org/abs/2410.11126v2 Label-free subcellular 3D imaging of oocytes and embryos via reflection matrix microscopy 2026-04-16T15:55:47Z Non-invasive morphological assessment is the cornerstone of oocyte and embryo selection in assisted reproductive technology, yet clinical practice remains limited by two-dimensional, qualitative microscopy. While three-dimensional (3D) fluorescence imaging provides cellular insights, its inherent phototoxicity precludes routine clinical use. Conversely, existing label-free modalities fail to resolve subcellular structures in thick specimens due to two distinct physical barriers: large-scale refractive index heterogeneities, such as the cumulus cells surrounding oocytes, that induce severe aberrations; and short-scale fluctuations, primarily from cytoplasmic lipids, that generate a multiple scattering ``fog''. Here, we report an ultra-fast Reflection Matrix Imaging (RMI) platform designed to overcome these depth and resolution limits. By capturing the back-scattered electromagnetic field for a set of plane-wave illuminations at multiple wavelengths, we record a multi-spectral reflection matrix. From this matrix, we leverage digital adaptive focusing algorithms to computationally compensate for sample-induced aberrations while realigning forward multiple scattering trajectories with the single-scattering contribution. This approach enables label-free 3D visualization of oocytes and blastocysts with an unprecedented subcellular resolution of 300 nm throughout the entire specimen volume. We demonstrate the reliable identification of germinal vesicles and nuclear status in stages previously inaccessible to conventional optics, including imaging through dense cumulus cells. Our method provides a powerful, non-invasive tool for objective grading across all pre-implantation stages, potentially transforming decision-making in clinical IVF. 2024-10-14T22:29:16Z 32 pages, 11 figures, 1 table Elsa Giraudat Victor Barolle Flavien Bureau Nicolas Guigui Paul Balondrade Christine Ho Vincent Brochard Olivier Dubois Amélie Bonnet-Garnier Alexandre Aubry http://arxiv.org/abs/2602.14394v2 Increasing ultrasound field-of-view with reduced element count arrays containing large elements 2026-04-16T14:07:53Z Several applications of medical ultrasound can benefit from a larger field of view (FOV). This study is aimed at increasing the FOV of linear array probes by increasing the element width. Coupled elements were used to imitate a larger element width. Through Fourier analysis, theoretical pressure amplitudes, and bandwidth estimates, coupled elements are shown to be close approximations of large elements. The effects of coupling on resolution, contrast, and speckle signal-to-noise ratio are investigated through phantom images and in-vivo images of a rabbit tumor reconstructed with plane-wave compounding. Furthermore, a positioning system was used to acquire data from a virtual large aperture with 120 mm FOV and 128 elements, collected in sections with a single probe. The Null Subtraction Imaging (NSI), Sign Coherence Factor (SCF), and Minimum Variance (MV) beamformers are compared for regaining resolution lost by an increased F-number. The NSI beamformer decreased Full-Width at Half-Max (FWHM) estimates of wire targets by 79% with coupling by 2 compared to uncoupled DAS. The MV beamformer was best for maintaining speckle statistics while improving resolution. Our results demonstrate how increased element width can increase FOV with no increase to element count. 2026-02-16T01:56:09Z Mick Gardner Rita J. Miller Michael L. Oelze http://arxiv.org/abs/2602.15174v2 Large elements and advanced beamformers for increased field of view in 2-D ultrasound matrix arrays 2026-04-16T13:56:26Z Three-dimensional (3D) ultrasound promises various medical applications for abdominal, obstetrics, and breast imaging. However, ultrasound matrix arrays have extremely high element counts limiting their field of view (FOV). Current reduced element count architectures, such as row-column arrays, diverging lenses, or sparse arrays, suffer from limited resolution and high side- and grating-lobe levels. This work seeks to demonstrate an increased field-of-view using a reduced element count array design. The approach is to increase the element size and use advanced beamformers to maintain image quality. The delay and sum (DAS), Null Subtraction Imaging (NSI), directional coherence factor (DCF), and Minimum Variance (MV) beamformers were compared. K-wave simulations of the 3D point-spread functions (PSF) of NSI, DCF, and MV display reduced side lobes and narrowed main lobes compared to DAS. Experiments were conducted using a multiplexed 1024-element matrix array on a Verasonics 256 system. Elements were electronically coupled to imitate a larger pitch and element size. Then, a virtual large aperture was created by using a positioning system to collect data in sections with the matrix array. Resolution and contrast was also assessed on a rabbit liver in vivo. Resolution was maintained using coupling numbers up to four, doubling the FOV while reducing the element count. The NSI and DCF beamformers demonstrated the best resolution performance in simulations, in a phantom with the virtual aperture, and in vivo on a rabbit liver. Our results demonstrate how larger matrix arrays could be constructed with larger elements, with resolution maintained by advanced beamformers. 2026-02-16T20:25:16Z Mick Gardner Michael L. Oelze http://arxiv.org/abs/2604.14800v1 Generative Modeling of Complex-Valued Brain MRI Data 2026-04-16T09:24:26Z Objective. Standard Magnetic Resonance Imaging (MRI) reconstruction pipelines discard phase information captured during acquisition, despite evidence that it encodes tissue properties relevant to tumor diagnosis. Current machine learning approaches inherit this limitation by operating exclusively on reconstructed magnitude images. The aim of this study is to build a generative framework which is capable of jointly modeling magnitude and phase information of complex-valued MRI scans. Approach. The proposed generative framework combines a conditional variational autoencoder, which compresses complex-valued MRI scans into compact latent representations while preserving phase coherence, with a flow-matching-based generative model. Synthetic sample quality is assessed via a real-versus-synthetic classifier and by training downstream classifiers on synthetic data for abnormal tissue detection. Main results. The autoencoder preserves phase coherence above 0.997. Real-versus-synthetic classification yields low AUROC values between 0.50 and 0.66 across all acquisition sequences, indicating generated samples are nearly indistinguishable from real data. In downstream normal-versus-abnormal classification, classifiers trained entirely on synthetic data achieve an AUROC of 0.880, surpassing the real-data baseline of 0.842 on a publicly available dataset (fastMRI). This advantage persists on an independent external test set from a different institution with biopsy-confirmed labels. Significance. The proposed framework demonstrates the feasibility of jointly modeling magnitude and phase information for normal and abnormal complex-valued brain MRI data. Beyond synthetic data generation, it establishes a foundation for the usage of complete brain MRI information in future diagnostic applications and enables systematic investigation of how magnitude and phase jointly encode pathology-specific features. 2026-04-16T09:24:26Z 16 pages, 8 figures Marco Schlimbach Moritz Rempe Jessica Mnischek Lukas T. Rotkopf Jens Weingarten Jens Kleesiek Kevin Kröninger http://arxiv.org/abs/2604.14494v1 A wearable electrical hemodynamic imaging ring 2026-04-16T00:05:56Z Continuous ambulatory monitoring of peripheral vascular perfusion could enable earlier detection of vascular dysfunction in individuals with diabetes mellitus and more timely management of cardiovascular disease. Clinical imaging modalities provide high-fidelity vascular information but are impractical for ambulatory use, whereas most wearable devices are limited to single-modality sensing and do not provide imaging. Electrical bioimpedance has the potential to bridge this gap by enabling rapid spatial and temporal imaging while remaining sensitive to hemodynamic changes. Here, we introduce a wearable ring with 8 electrodes and 32-channel bioimpedance sensing for finger blood flow imaging. In 96 healthy participants measured at rest and during autonomic maneuvers, we resolve conductivity images in the digital arteries associated with pulsatile blood flow and train neural network models for continuous cuffless blood pressure waveform estimation. We demonstrate the feasibility of bioimpedance imaging in a ring form factor, supporting its potential for ambulatory cuffless hemodynamic monitoring. 2026-04-16T00:05:56Z Gia-Bao Ha Lucas Takanori Sanchez Shiromizu Jaehyeon Song Zhuyun Xie Henry Crandall Dinali Assylbek Alexandra Boyadzhiev Huanan Zhang Fernando Guevara Vasquez Ramakrishna Mukkamala Michael Widlansky Shamim Nemati Jesse Capecelatro C. Alberto Figueroa Benjamin Sanchez http://arxiv.org/abs/2512.17654v3 Learning-Based Estimation of Spatially Resolved Scatter Radiation Fields in Interventional Radiology 2026-04-15T12:59:08Z We present three variants of a lightweight, fully connected artificial neural network, suited for interactive estimation of three-dimensional, spatially resolved volumes of scattered radiation fields and a corresponding training pipeline for radiation protection dosimetry in medical radiation fields, such as those found in interventional radiology and cardiology. Accompanying, we present three different synthetically generated datasets with increasing complexity for training, generated using RadField3D, a Monte Carlo simulation application based on Geant4. As the primary scatter object, we employed the torso of a male Alderson RANDO phantom. On those datasets, we evaluate convolutional and fully connected architectures of neural networks to demonstrate which design decisions work well for reconstructing the fluence and spectra distributions over the spatial domain of such radiation fields. All our datasets, as well as our training pipeline, are published as open source in separate repositories. To evaluate the presented neural networks, we define and assess several metrics. Across these measures, the model variants demonstrate good spatial agreement between predicted and ground-truth radiation fields, particularly within specific regions of interest within the radiation field. Of particular relevance for potential application in out-of-field dosimetry is the SMAPE of the scatter radiation field, which represents the most challenging metric and was consistently above 84 %. 2025-12-19T14:52:04Z Felix Lehner Pasquale Lombardo Susana Castillo Oliver Hupe Marcus Magnor http://arxiv.org/abs/2604.10227v3 Voxel-Based Conversion of Hypofractionated Radiotherapy Dose Distributions to 2 Gy-Equivalent OAR Constraints: Proof-of-Concept Demonstrating the Radiobiological Benefits of Hypofractionation in a Prostate Radiotherapy Case 2026-04-15T06:08:26Z Objectives: Existing voxel-based dose converters transform hypofractionated dose distributions into biologically effective dose (BED) or equivalent dose in 2 Gy fractions (EQD2), but they are not reliably applicable to organ-at-risk (OAR) dose constraints, particularly in low-dose regions, which may lead to dose misinterpretation. This study develops and demonstrates a voxel-based method to convert hypofractionated dose distributions into 2 Gy-equivalent OAR constraints. Methods: To2GyConstraints converter (www.healthy-innovations.com) was applied to a prostate cancer case. The method uses the Linear Quadratic (LQ) model for doses per fraction less than or equal to 7.5 Gy and the Linear Quadratic Linear (LQ-L) model for higher doses. For voxel fraction doses below a threshold defined as the mean between the prescribed hypofractionated fraction dose and 2 Gy, an equivalent number of fractions is calculated. The method then applies an EQDx-type conversion, rather than EQD2, using this calculated fraction number to better reproduce normofractionated dose behavior. Results: For doses above the defined threshold, unlike BED, the To2GyConstraints model produced results consistent with EQD2 and provided clinically realistic dose values comparable to standard dosimetric constraints, thereby offering a clearer demonstration of the radiobiological benefits of hypofractionation in prostate cancer. For doses below the threshold, unlike EQD2, the To2GyConstraints model showed behavior consistent with BED, yielding higher dose estimates when converted to a normofractionation scheme. Conclusions: To2GyConstraints converter shows promising results for radiobiological interpretation of hypofractionation. Further multicenter validation is required. Advances in knowledge: A voxel-based method enabling application of normofractionation OAR constraints to hypofractionated dosimetry after conversion. 2026-04-11T14:24:59Z Mazen Moussallem Healthy Innovations, Rachiine, Zgharta, Lebanon Holy Family University, Batroun, Lebanon Tripoli Governmental Hospital and Doctors Center, Kobbe, Tripoli, Lebanon Dima Mahmoud Tripoli Governmental Hospital and Doctors Center, Kobbe, Tripoli, Lebanon Antoine Nassif Healthy Innovations, Rachiine, Zgharta, Lebanon http://arxiv.org/abs/2506.13539v2 Direct optimization of the probability of lesion origin in proton treatment planning for low-grade glioma patients 2026-04-14T20:24:36Z In proton therapy of low-grade glioma (LGG) patients, contrast-enhancing brain lesions (CEBLs) on magnetic resonance imaging are considered predictive of late radiation-induced lesions. From the observation that CEBLs tend to concentrate in regions of increased dose-averaged linear energy transfer (LET$_{\text{d}}$) and proximal to the ventricular system, the probability of lesion origin (POLO) model has been established as a multivariate logistic regression model for the voxel-wise probability prediction of the CEBL origin. To date, leveraging the predictive power of the POLO model for treatment planning relies on hand tuning the dose and LET$_{\text{d}}$ distribution to minimize the resulting probability predictions. In this paper, we therefore propose automated POLO model-based treatment planning by directly integrating POLO calculation and optimization into plan optimization for LGG patients. We introduce an extension of the original POLO model including a volumetric correction factor, and a model-based optimization scheme featuring a linear reformulation of the model together with feasible optimization functions based on the predicted POLO values. The developed framework is implemented in the open-source treatment planning toolkit matRad. Our framework can generate clinically acceptable treatment plans while automatically taking into account outcome predictions from the POLO model. It also supports the definition of customized POLO model-based objective and constraint functions. Optimization results from a sample LGG patient show that the POLO model-based outcome predictions can be minimized under expectable shifts in dose, LET$_{\text{d}}$, and POLO distributions, while sustaining target coverage ($Δ_{\text{PTV}} \text{D95}_{RBE,fx}\approx{0.00}$, $Δ_{\text{GTV}} \text{D95}_{RBE,fx}\approx{0.03}$), even when NTCP is strongly down-regulated. 2025-06-16T14:27:08Z 36 pages, 10 figures, 3 tables, partly already presented at PTCOG 62 Med Phys. 2026;53:e70395 Tim Ortkamp Habiba Sallem Semi Harrabi Martin Frank Oliver Jäkel Julia Bauer Niklas Wahl 10.1002/mp.70395 http://arxiv.org/abs/2604.13282v1 Agentic MR sequence development: leveraging LLMs with MR skills for automatic physics-informed sequence development 2026-04-14T20:17:47Z Purpose: Novel MR sequence developments still today allow generation of new diagnostic tools or novel imaging biomarkers. Programming MRI pulse sequences, however, is time-consuming and requires deep expertise in sequence design, restrictions by hardware constraints and MRI physics; even small modifications often require substantial debugging and validation. LLMs can assist when given structured prompts and error feedback, but many generated sequences still exhibit physical inconsistencies. We present Agent4MR, an agent-based framework that automatically generates and refines PyPulseq sequences using a structured, physics-aware validation report. These agents can perform also autonomous research. Methods: We evaluated Agent4MR on a spin-echo EPI task across three state-of-the-art LLMs and compared it to a context-only baseline (LLM4MR) and to a human developer with the same tools. We tested an MR autoresearch on a fluid-suppressed spin-echo EPI challenge for three different model generations. Results: Across all models, Agent4MR consistently produced artifact-free, physically valid sequences in a single user interaction, reducing the number of required interactions below the human baseline while maintaining correct timing and k-space coverage. Autonomous agents could then improve a sequence to match a given target contrast in an autoresearch approach. Conclusion: An appropriate agentic harness with physics-based validation can turn general-purpose LLMs into reliable MRI sequence developers and may ultimately enable non-experts to refine or innovate MR sequences guided by biological or clinical questions, or let swarms of agents realize sequence programming for them. Keywords: MRI; pulse sequence; PyPulseq; large language models; agents; autoresearch, sequence development. 2026-04-14T20:17:47Z Word count abstract/body: 223 / 4303 Moritz Zaiss Amr Aly Jonathan Endres Tobias Dornstetter Simon Weinmüller Andreas Maier http://arxiv.org/abs/2509.03398v3 Multi-Wavelength Machine Learning for High-Precision Colorimetric Sensing 2026-04-14T20:10:06Z Conventional colorimetric sensing methods typically rely on signal intensity at a single wavelength, often selected heuristically based on peak visual modulation. This approach overlooks the structured information embedded in full-spectrum transmission profiles, particularly in intensity-based systems where linear models may be highly effective. In this study, we experimentally demonstrate that applying a forward feature selection strategy to normalized transmission spectra, combined with linear regression and ten-fold cross-validation, yields significant improvements in predictive accuracy. Using food dye dilutions as a model system, the mean squared error was reduced from over 22,000 with a single wavelength to 3.87 using twelve selected features, corresponding to a more than 5,700-fold enhancement. These results validate that full-spectrum modeling enables precise concentration prediction without requiring changes to the sensing hardware. The approach is broadly applicable to colorimetric assays used in medical diagnostics, environmental monitoring, and industrial analysis, offering a scalable pathway to improve sensitivity and reliability in existing platforms. 2025-09-03T15:20:36Z 15 pages, 7 figures, 1 table Majid Aalizadeh Chinmay Raut Ali Tabartehfarahani Xudong Fan http://arxiv.org/abs/2512.21652v2 Enabling Ultra-Fast Cardiovascular Imaging Across Heterogeneous Clinical Environments with A Generalist Foundation Model and Multimodal Database 2026-04-14T15:24:36Z Multimodal cardiovascular magnetic resonance (CMR) imaging provides comprehensive and non-invasive insights into cardiovascular disease (CVD) diagnosis and underlying mechanisms. Despite decades of advancements, its widespread clinical adoption remains constrained by prolonged scan times, inconsistent image quality, and heterogeneity across medical environments. This underscores the urgent need for a generalist reconstruction foundation model for ultra-fast CMR imaging, one formulated for physics-constrained inverse problems in the sensor (k-space) domain, capable of adapting across diverse imaging scenarios and serving as the essential substrate for all downstream analyses. To enable this goal, we curate MMCMR-427K, the largest and most comprehensive multimodal CMR k-space database to date, comprising 427,465 multi-coil k-space data paired with structured metadata across 13 international centers, 12 CMR modalities, 15 scanners spanning four field strengths, and 17 CVD categories in populations across three continents. Building on this unprecedented resource, we introduce CardioMM, a generalist reconstruction foundation model capable of dynamically adapting to heterogeneous fast CMR imaging scenarios. CardioMM unifies semantic contextual understanding with physics-informed data consistency to deliver robust reconstructions across varied scanners, protocols, and patient presentations. Comprehensive evaluations demonstrate that CardioMM achieves state-of-the-art performance across internal centers and exhibits strong zero-shot generalization to unseen external settings. Importantly, CardioMM supports acceleration up to 24x, providing the first evidence that such extreme acquisition speed can preserve key cardiac phenotypes, quantitative myocardial biomarkers, and diagnostic image quality without compromising clinical integrity. 2025-12-25T12:47:50Z Github: https://github.com/wangziblake/CardioMM_MMCMR-427K Zi Wang Mingkai Huang Zhang Shi Hongjie Hu Lan Lan Hui Zhang Yan Li Xi Hu Qing Lu Zongming Zhu Qiong Yao Yuxiang Dai Fanwen Wang Yinzhe Wu Jun Lyu Qianqian Gao Guangming Xu Zhenxuan Zhang Haosen Zhang Qing Li Guangming Wang Tianxing He Lizhen Lan Siyue Li Le Xue Mengting Sun Yuntong Lyu Junpu Hu Jiayu Zhu Rizwan Ahmad Zhengyu Bu Xianling Qian Guanke Cai Ruiyu Cao Weirui Cai Chang Xu Yuyang Ren Feidan Yu Siying Ma Ziqiang Xu Xinran Chen Sha Hua Daniel Kim Yajing Zhang Chen Ouyang Wenjia Bai Jing Qin Yucheng Yang Daniel Rueckert He Wang Qian Tao Claudia Prieto Michael Markl Alistair Young Lianming Wu Shuo Wang Chen Qin Mengsu Zeng Xihong Hu Haibo Xu Xiaobo Qu Hao Li Guang Yang Chengyan Wang