https://arxiv.org/api/22+GLYRikk6rXlQ0m5m1epksBK02026-04-09T14:24:43Z880821015http://arxiv.org/abs/2602.03744v2Reducing acquisition time and radiation damage: data-driven subsampling for spectro-microscopy2026-02-04T10:15:44ZSpectro-microscopy is an experimental technique which can be used to observe spatial variations in chemical state and changes in chemical state over time or under experimental conditions. As a result it has broad applications across areas such as energy materials, catalysis, environmental science and biological samples. However, the technique is often limited by factors such as long acquisition times and radiation damage. We present two measurement strategies that allow for significantly shorter experiment times and total doses applied. The strategies are based on taking only a small subset of all the measurements (e.g. sparse acquisition or subsampling), and then computationally reconstructing all unobserved measurements using mathematical techniques. The methods are data-driven, using spectral and spatial importance subsampling distributions to identify important measurements. As a result, taking as little as 4-6\% of the measurements is sufficient to capture the same information as in a conventional scan.2026-02-03T17:05:27ZMaike MeierLorenzo LazzarinoBoris ShustinHussam Al DaasPaul Quinnhttp://arxiv.org/abs/2602.03281v2Physics-Based Learning of the Wave Speed Landscape in Complex Media2026-02-04T09:03:08ZWave velocity is a key parameter for imaging complex media, but in vivo measurements are typically limited to reflection geometries, where only backscattered waves from short-scale heterogeneities are accessible. As a result, conventional reflection imaging fails to recover large-scale variations of the wave velocity landscape. Here we show that matrix imaging overcomes this limitation by exploiting the quality of wave focusing as an intrinsic guide star. We model wave propagation as a trainable multi-layer network that leverages optimization and deep learning tools to infer the wave velocity distribution. We validate this approach through ultrasound experiments on tissue-mimicking phantoms and human breast tissues, demonstrating its potential for tumour detection and characterization. Our method is broadly applicable to any kind of waves and media for which a reflection matrix can be measured.2026-02-03T09:04:49Z40 pages, 8 figures, 1 tableBaptiste Hériard-DubreuilEmma BrennerBenjamin RioWilliam LambertFoucauld Chamming'sMathias FinkAlexandre Aubryhttp://arxiv.org/abs/2602.03622v1Quasi-multimodal-based pathophysiological feature learning for retinal disease diagnosis2026-02-03T15:13:57ZRetinal diseases spanning a broad spectrum can be effectively identified and diagnosed using complementary signals from multimodal data. However, multimodal diagnosis in ophthalmic practice is typically challenged in terms of data heterogeneity, potential invasiveness, registration complexity, and so on. As such, a unified framework that integrates multimodal data synthesis and fusion is proposed for retinal disease classification and grading. Specifically, the synthesized multimodal data incorporates fundus fluorescein angiography (FFA), multispectral imaging (MSI), and saliency maps that emphasize latent lesions as well as optic disc/cup regions. Parallel models are independently trained to learn modality-specific representations that capture cross-pathophysiological signatures. These features are then adaptively calibrated within and across modalities to perform information pruning and flexible integration according to downstream tasks. The proposed learning system is thoroughly interpreted through visualizations in both image and feature spaces. Extensive experiments on two public datasets demonstrated the superiority of our approach over state-of-the-art ones in the tasks of multi-label classification (F1-score: 0.683, AUC: 0.953) and diabetic retinopathy grading (Accuracy:0.842, Kappa: 0.861). This work not only enhances the accuracy and efficiency of retinal disease screening but also offers a scalable framework for data augmentation across various medical imaging modalities.2026-02-03T15:13:57ZZhang, L., Yu, H., Wang, Z., Gui, F., Guo, Y., Zhang, W., Jia, M., 2026. Quasi-multimodal-based pathophysiological feature learning for retinal disease diagnosis. Medical Image Analysis 109, 103886Lu ZhangHuizhen YuZuowei WangFu GuiYatu GuoWei ZhangMengyu Jia10.1016/j.media.2025.103886http://arxiv.org/abs/2505.18782v5Joint Reconstruction of Activity and Attenuation in PET by Diffusion Posterior Sampling in Wavelet Coefficient Space2026-02-03T14:32:01ZAttenuation correction (AC) is necessary for accurate activity quantification in positron emission tomography (PET). Conventional reconstruction methods typically rely on attenuation maps derived from a co-registered computed tomography (CT) or magnetic resonance imaging (MRI) scan. However, this additional scan may complicate the imaging workflow, introduce misalignment artifacts and increase radiation exposure. In this paper, we propose a joint reconstruction of activity and attenuation (JRAA) approach that eliminates the need for auxiliary anatomical imaging by relying solely on emission data. This framework combines wavelet diffusion model (WDM) and diffusion posterior sampling (DPS) to reconstruct fully three-dimensional (3-D) data. Experimental results show our method outperforms maximum likelihood activity and attenuation (MLAA) and MLAA with U-Net-based post processing, and yields high-quality noise-free reconstructions across various count settings when time-of-flight (TOF) information is available. It is also able to reconstruct non-TOF data, although the reconstruction quality significantly degrades in low-count (LC) conditions, limiting its practical effectiveness in such settings. Nonetheless, a non-TOF Biograph mMR data reconstruction with joint scatter estimation highlights the potential of the method for clinical applications. This approach represents a step towards stand-alone PET imaging by reducing the dependence on anatomical modalities while maintaining quantification accuracy, even in low-count scenarios when TOF information is available. Our code is available on GitHub at https://github.com/clemphg/jraa-dps.2025-05-24T16:39:50Z14 pages, 8 figures, 3 tablesClémentine Phung-NgocAlexandre BousseAntoine De PaepeThibaut MerlinBaptiste LaurentHong-Phuong DangOlivier SautCatherine Cheze-Le-RestDimitris Visvikishttp://arxiv.org/abs/2602.03437v1Accelerated Electromagnetic Simulation of MRI RF Interactions with Graphene Microtransistor-Based Neural Probes for Electrophysiology-fMRI Integration2026-02-03T12:01:20ZImplementing electrophysiological recordings within an MRI environment is challenging due to complex interactions between recording probes and MRI-generated fields, which can affect both safety and data quality. This study aims to develop and evaluate a hybrid electromagnetic (EM) simulation framework for efficient and accurate assessment of such interactions. Methods: A hybrid EM strategy integrating the Huygens' Box (HB) method with sub-gridding was implemented in an FDTD solver (Sim4Life). RF coil models for mouse and rat head were simulated with and without intracortical (IC) and epicortical (EC) graphene-based micro-transistor arrays. Three-dimensional multi-layered probe models were reconstructed from two-dimensional layouts, and transmit field ($B_{1}^{+}$), electric field ($E$), and specific absorption rate (SAR) distributions were evaluated. Performance was benchmarked against conventional full-wave multi-port (MP) simulations using Bland-Altman analysis and voxel-wise percentage differences. Results: HB simulations reduced computational time by approximately 70-80%, while preserving spatial patterns of $|B_{1}^{+}|$, $|E|$, and SAR, including transmit-field symmetry and localized high-field regions. Deviations from MP were minimal for $|B_{1}^{+}|$ (median $Δ$% 0.02-0.07% in mice, -3.7% to -1.7% in rats) and modest for $|E|$ and SAR, with absolute SAR values remaining well below human safety limits. Graphene-based arrays produced negligible effects on RF transmission and SAR deposition. Conclusion: The HB approach enables computationally efficient, high-resolution evaluation of EM interactions involving microscopic probes in MRI environments, supporting simulations that are otherwise impractical with full-wave MP modeling.2026-02-03T12:01:20ZSuchit KumarAlejandro Labastida RamirezSamuel M FlahertyAnton Guimera BrunetNerea Alvarez de EulateKostas KostarelosBen DickieRob C WykesLouis Lemieuxhttp://arxiv.org/abs/2409.16085v3Super-resolution positron emission tomography by intensity modulation: Proof of concept2026-02-03T10:02:00ZWe proposed a new approach, which is inspired by the method of super-resolution (SR) structured illumination microscopy (SIM) for overcoming the resolution limit in microscopy due to diffraction of light, for increasing the resolution of clinical positron emission tomography (PET) beyond its instrumentation limit. We implemented the key idea behind SR-SIM by using a rotating intensity modulator in front of a stationary PET detector ring. Its function is to modulate down high-frequency signals of the projection data that originally were above the system's bandwidth and unobservable to appear as aliased lower-frequency ones that are detectable. We formulated a model that relates an image whose resolution is above the instrumentation limit to several thus obtained limited-resolution measurements at various rotational positions of the modulator. We implemented an ordered-subsets expectation-maximization algorithm for inverting the model. Using noise-free data produced by an analytic projector, we showed this approach can resolve 0.9 mm sources when applied to a PET system that employs 4.2 mm-width detectors. With noisy data, the SR performance remains promising. In particular, 1.5 mm sources were resolvable, and the visibility and quantification of small sources and fine structures were improved despite the sensitivity loss incurred by the modulator. These observations remain valid when using more realistic Monte-Carlo simulation data. More studies are needed to better understand the theoretical aspects of the proposed method and to optimize the design of the modulator and the reconstruction algorithm.2024-09-24T13:35:15Z15 pages, 12 figuresYoudong LangQingguo XieChien-Min Kaohttp://arxiv.org/abs/2602.03317v1Multiparameter Uncertainty Mapping in Quantitative Molecular MRI using a Physics-Structured Variational Autoencoder (PS-VAE)2026-02-03T09:46:55ZQuantitative imaging methods, such as magnetic resonance fingerprinting (MRF), aim to extract interpretable pathology biomarkers by estimating biophysical tissue parameters from signal evolutions. However, the pattern-matching algorithms or neural networks used in such inverse problems often lack principled uncertainty quantification, which limits the trustworthiness and transparency, required for clinical acceptance. Here, we describe a physics-structured variational autoencoder (PS-VAE) designed for rapid extraction of voxelwise multi-parameter posterior distributions. Our approach integrates a differentiable spin physics simulator with self-supervised learning, and provides a full covariance that captures the inter-parameter correlations of the latent biophysical space. The method was validated in a multi-proton pool chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) molecular MRF study, across in-vitro phantoms, tumor-bearing mice, healthy human volunteers, and a subject with glioblastoma. The resulting multi-parametric posteriors are in good agreement with those calculated using a brute-force Bayesian analysis, while providing an orders-of-magnitude acceleration in whole brain quantification. In addition, we demonstrate how monitoring the multi-parameter posterior dynamics across progressively acquired signals provides practical insights for protocol optimization and may facilitate real-time adaptive acquisition.2026-02-03T09:46:55ZSubmitted to IEEE Transactions on Medical Imaging. This project was funded by the European Union (ERC, BabyMagnet, project no. 101115639). Views and opinions expressed are, however, those of the authors only and do not necessarily reflect those of the European Union or the European Research Council. Neither the European Union nor the granting authority can be held responsible for themAlex FinkelsteinRon MonetaOr ZoharMichal RivlinMoritz ZaissDinora Friedmann MorvinskiOr Perlmanhttp://arxiv.org/abs/2602.02713v1Perfusion Imaging and Single Material Reconstruction in Polychromatic Photon Counting CT2026-02-02T19:27:55ZBackground: Perfusion computed tomography (CT) images the dynamics of a contrast agent through the body over time, and is one of the highest X-ray dose scans in medical imaging. Recently, a theoretically justified reconstruction algorithm based on a monotone variational inequality (VI) was proposed for single material polychromatic photon-counting CT, and showed promising early results at low-dose imaging.
Purpose: We adapt this reconstruction algorithm for perfusion CT, to reconstruct the concentration map of the contrast agent while the static background tissue is assumed known; we call our method VI-PRISM (VI-based PeRfusion Imaging and Single Material reconstruction). We evaluate its potential for dose-reduced perfusion CT, using a digital phantom with water and iodine of varying concentration.
Methods: Simulated iodine concentrations range from 0.05 to 2.5 mg/ml. The simulated X-ray source emits photons up to 100 keV, with average intensity ranging from $10^5$ down to $10^2$ photons per detector element. The number of tomographic projections was varied from 984 down to 8 to characterize the tradeoff in photon allocation between views and intensity.
Results: We compare VI-PRISM against filtered back-projection (FBP), and find that VI-PRISM recovers iodine concentration with error below 0.4 mg/ml at all source intensity levels tested. Even with a dose reduction between 10x and 100x compared to FBP, VI-PRISM exhibits reconstruction quality on par with FBP.
Conclusion: Across all photon budgets and angular sampling densities tested, VI-PRISM achieved consistently lower RMSE, reduced noise, and higher SNR compared to filtered back-projection. Even in extremely photon-limited and sparsely sampled regimes, VI-PRISM recovered iodine concentrations with errors below 0.4 mg/ml, showing that VI-PRISM can support accurate and dose-efficient perfusion imaging in photon-counting CT.2026-02-02T19:27:55ZCode is available at https://github.com/voilalab/VI-PRISMNamhoon KimAshwin PananjadyAmir PourmortezaSara Fridovich-Keilhttp://arxiv.org/abs/2602.02471v1Multi-head automated segmentation by incorporating detection head into the contextual layer neural network2026-02-02T18:51:25ZDeep learning based auto segmentation is increasingly used in radiotherapy, but conventional models often produce anatomically implausible false positives, or hallucinations, in slices lacking target structures. We propose a gated multi-head Transformer architecture based on Swin U-Net, augmented with inter-slice context integration and a parallel detection head, which jointly performs slice-level structure detection via a multi-layer perceptron and pixel-level segmentation through a context-enhanced stream. Detection outputs gate the segmentation predictions to suppress false positives in anatomically invalid slices, and training uses slice-wise Tversky loss to address class imbalance. Experiments on the Prostate-Anatomical-Edge-Cases dataset from The Cancer Imaging Archive demonstrate that the gated model substantially outperforms a non-gated segmentation-only baseline, achieving a mean Dice loss of $0.013 \pm 0.036$ versus $0.732 \pm 0.314$, with detection probabilities strongly correlated with anatomical presence, effectively eliminating spurious segmentations. In contrast, the non-gated model exhibited higher variability and persistent false positives across all slices. These results indicate that detection-based gating enhances robustness and anatomical plausibility in automated segmentation applications, reducing hallucinated predictions without compromising segmentation quality in valid slices, and offers a promising approach for improving the reliability of clinical radiotherapy auto-contouring workflows.2026-02-02T18:51:25Z8 pages, 3 figures, 1 tableOA J Applied Sci Technol, 4(1), 01-07 (2026)Edwin KysFebian Febian10.33140/OAJAST.04.01.10http://arxiv.org/abs/2602.02616v1A space-time LATIN-PGD strategy for solving Newtonian compressible flows2026-02-02T12:36:02ZSimulating flow problems is at the core of many engineering applications but often requires high computational effort, especially when dealing with complex models. This work presents a novel approach for resolving flow problems using the LATIN-PGD solver. In this contribution, we place ourselves within the framework of Newtonian compressible and laminar flows. This specific and relatively simple case enables focusing on flows for which a state equation provides a direct relation between pressure and density. It is then possible to use the LATIN solver to set up a pressure-velocity decoupling algorithm. Moreover, Proper Generalised Decomposition (PGD) is natively included in the solver and yields two independent space-time decompositions for the velocity and the pressure fields. As a first step, the solver is validated on a problem for which an analytical solution is available. It is then applied to slightly more complex problems. The results show good agreement with the literature, and we expect that the solver could be used to compute more complicated material laws in the future.2026-02-02T12:36:02ZÉlise FoulatierLMPSPierre-Alain BoucardLMPSFrançois LoufLMPSDavid NéronLMPSPhilipp Junkerhttp://arxiv.org/abs/2602.01622v1The Contrast Order: An Order-Based Image Quality Criterion for Nonlinear Beamformers2026-02-02T04:33:55ZMany modern ultrasound beamformers report improved image quality when evaluated using classical criteria like the contrast ratio and contrast-to-noise ratio, which are based on summary statistics of regions of interest (ROIs). However, nonlinear beamformers and post-processing methods can substantially alter these statistics, raising concerns that the reported improvements may reflect changes in dynamic range or remapping rather than a reflection of true information gain, such as clutter suppression. New criteria like the generalized contrast-to-noise ratio (gCNR) address these concerns, but rely on noisy estimates of the underlying distribution. To address this, we introduce a new image quality criterion, called the contrast order (CO), defined as the expected value of the sign of the difference in brightness between two ROIs. The CO is invariant under all strictly monotonic transformations of the image values, as it depends only on their relative ordering, and is interpretable as the probability that one ROI is brighter than the other minus the probability that it is darker. Unlike the gCNR, the CO has a simple unbiased estimator whose variance decreases with the number of samples in each ROI. We further propose the effective contrast ratio (ECR), which calibrates the contrast order to the familiar contrast ratio such that the two coincide under ideal Rayleigh-speckle statistics. Together, the CO and ECR provide order- and sign-preserving, dynamic-range-invariant criteria for evaluating lesion contrast, offering a principled alternative to classical and newer image quality criteria when assessing modern beamformers.2026-02-02T04:33:55ZDongwoon Hyunhttp://arxiv.org/abs/2505.12261v2OpenPros: A Large-Scale Dataset for Limited View Prostate Ultrasound Computed Tomography2026-02-01T22:35:15ZProstate cancer is one of the most prevalent and deadly cancers among men, motivating the development of accurate and accessible imaging technologies for early detection. Ultrasound computed tomography (USCT) reconstructs quantitative tissue parameters such as speed-of-sound (SOS) and is a promising low-cost alternative to existing modalities. However, prostate USCT remains challenging due to limited-angle acquisition, strong tissue heterogeneity, bone-induced wave distortion, and the lack of large-scale, anatomically realistic datasets for method development and evaluation. We introduce OPENPROS, the first large-scale benchmark dataset for limited-angle prostate USCT, designed to systematically evaluate machine learning methods for quantitative inverse problems. OPENPROS contains over 280,000 paired samples of realistic 2D SOS maps and corresponding ultrasound full-waveform data, generated from anatomically accurate 3D digital prostate models derived from 4 clinical MRI/CT scans and 62 ex vivo prostate specimens with experimental ultrasound measurements. Wave propagation is simulated under clinically realistic configurations using open-source finite-difference time-domain and Runge-Kutta solvers. We provide standardized training, in-distribution, and out-of-distribution benchmarks and evaluate representative deep learning baselines. While learning-based methods substantially improve inference speed and reconstruction accuracy over physics-based approaches, results highlight persistent challenges in robustness, generalization, and high-resolution reconstruction quality. By publicly releasing OPENPROS, we establish a rigorous benchmark to support research in inverse problems, physics-guided learning, and operator learning, and to bridge the gap between machine learning research and practical USCT deployment. The dataset is available at https://open-pros.github.io/.2025-05-18T06:56:49ZHanchen WangYixuan WuYinan FengPeng JinLuoyuan ZhangShihang FengJames WiskinBaris TurkbeyPeter A. PintoBradford J. WoodSongting LuoYinpeng ChenEmad BoctorYouzuo Linhttp://arxiv.org/abs/2602.00684v1Multi-Compartment Volume Conductor with Complete Electrode Model: Simulated Stereo-EEG Source Localization using Brainstorm-Zeffiro Plugin2026-01-31T12:05:13ZThis study introduces a novel integration of the Brainstorm (BST) software and the Zeffiro Interface (ZI) to enable whole-head, multi-compartment volume conductor modeling for electroencephalography (EEG) source imaging, with a particular focus on stereotactic EEG applications. We present the BST-2-ZI plugin, a MATLAB-based tool that facilitates seamless transfer of tissue segmentations and anatomical atlases from BST into ZI for finite element (FE) mesh generation as well as forward and inverse modeling. The generated FE meshes support variable spatial resolution and implement the complete electrode model (CEM), allowing for precise modeling of both invasive depth electrodes and non-invasive scalp electrodes. Using the ICBM152 template and synthetic source simulation, we demonstrate the end-to-end pipeline from MRI data to lead field (LF) computation and source localization in a stereotactic EEG (stereo-EEG) setting. Our numerical experiments highlight the capability of the pipeline to accurately model multi-compartment head geometry and conductivity with a stereotactic CEM-based electrode configuration. Our preliminary source localization results show how a synthetic stereo-EEG probe corresponding to a bidirectional deep brain stimulation (DBS) probe with four omnidirectional contacts can, in principle, be coupled with scalp electrodes to improve source localization in its vicinity.2026-01-31T12:05:13ZFernando Galaz PrietoTakfarinas MedaniChinmay ChinaraRichard M. LeahySampsa Pursiainenhttp://arxiv.org/abs/2602.00669v1Improving Neuropathological Reconstruction Fidelity via AI Slice Imputation2026-01-31T11:34:01ZNeuropathological analyses benefit from spatially precise volumetric reconstructions that enhance anatomical delineation and improve morphometric accuracy. Our prior work has shown the feasibility of reconstructing 3D brain volumes from 2D dissection photographs. However these outputs sometimes exhibit coarse, overly smooth reconstructions of structures, especially under high anisotropy (i.e., reconstructions from thick slabs). Here, we introduce a computationally efficient super-resolution step that imputes slices to generate anatomically consistent isotropic volumes from anisotropic 3D reconstructions of dissection photographs. By training on domain-randomized synthetic data, we ensure that our method generalizes across dissection protocols and remains robust to large slab thicknesses. The imputed volumes yield improved automated segmentations, achieving higher Dice scores, particularly in cortical and white matter regions. Validation on surface reconstruction and atlas registration tasks demonstrates more accurate cortical surfaces and MRI registration. By enhancing the resolution and anatomical fidelity of photograph-based reconstructions, our approach strengthens the bridge between neuropathology and neuroimaging. Our method is publicly available at https://surfer.nmr.mgh.harvard.edu/fswiki/mri_3d_photo_recon2026-01-31T11:34:01Z12 pages of main content, 5 pages of supplementMarina Crespo AguirreJonathan Williams-RamirezDina ZemlyankerXiaoling HuLucas J. Deden-BinderRogeny HerisseMark MontineTheresa R. ConnorsChristopher MountChristine L. MacDonaldC. Dirk KeeneCaitlin S. LatimerDerek H. OakleyBradley T. HymanAna Lawry AguilaJuan Eugenio Iglesiashttp://arxiv.org/abs/2602.00368v1Enhancing Imaging Depth and Sensitivity in Reflectance Mode Near Infrared Optical Imaging with Scatter Reducing Agents2026-01-30T22:31:46ZWe investigate the role of scatter reducing agents in a continuous wave (CW) near infrared (NIR)reflectance mode imaging setting. We use food-grade dye Tartrazine as a scatter reducing agent to enhance depth sensitivity and weak-absorber detectability in CW diffuse reflectance measurements. We found that reflectance signal was enhanced when the dye was applied on chicken breast phantom. However, we saw reduced reflectance sensitivity when the dye was uniformly dissolved in intralipid phantom which is a commonly used for NIR imaging studies. This shows that the gradient of refractive index modulation created as the dye diffuses from the top layer allows increased reflectance signal sensitivity of optical photons. However, when the scatter reduction is uniform throughout the phantom (like in intralipid phantom), the improved reflectance sensitivity was not observed. Our study points to significant redistribution of photons with scatter modulation with Tartrazine dye. We show significant improvement in sensitivity to signals with reflectance imaging. To elucidate the underlying mechanism of dye induced scatter reduction in tissue, analytical diffusion models and Monte Carlo simulations were employed. Modeling results show the impact of refractive index gradient created due to dye diffusion in enhancing reflectance sensitivity. These findings demonstrate that dye induced scatter reduction provides a practical, low-complexity approach to improving depth sensitivity in CW diffuse reflectance measurements and extend the functional capabilities of CW-NIRS systems for deep-tissue sensing applications. Our preliminary studies shows up to five fold enhancement in signal sensitivity for signals between two and three cm depth.2026-01-30T22:31:46Z26 pages, 10 figuresMannu Bardhan PaulKaiser NiknamMini Das