https://arxiv.org/api/WT5e6tuduHjAybzf2ms6ljms6bI 2026-06-21T17:18:45Z 8985 195 15 http://arxiv.org/abs/2510.03248v3 Multimodal Neural Operators for Real-Time Biomechanical Modelling of Traumatic Brain Injury 2026-04-23T21:10:02Z Background: Traumatic brain injury modeling requires integrating volumetric neuroimaging, demographic parameters, and acquisition metadata. Finite element solvers are too computationally expensive for clinical settings. Neural operators offer much faster inference. Their ability to integrate volumetric imaging with scalar metadata remains underexplored for biomechanical predictions. Objective: This study evaluates multimodal neural operator architectures for brain biomechanics. We test strategies fusing volumetric anatomical imaging, demographic features, and acquisition parameters to predict full-field brain displacement from MRE data. Methods: We framed TBI modeling as a multimodal operator learning problem. Two fusion strategies were tested. Field projection was applied for Fourier Neural Operator (FNO) architectures. Branch decomposition was used for Deep Operator Networks (DeepONet). Four models (FNO, Factorized FNO, Multi-Grid FNO, DeepONet) were evaluated on 249 in vivo MRE datasets across frequencies from 20 to 90 Hz. Results: DeepONet achieved the highest accuracy on real displacement fields (MSE = 0.0039, 90.0% accuracy) with the fastest inference (3.83 it/s) and fewest parameters (2.09M). MG-FNO performed best on imaginary fields (MSE = 0.0058, 88.3% accuracy) requiring the lowest GPU memory among FNO variants (7.12 GB). No single architecture dominated all criteria. This reveals distinct trade-offs between accuracy, spatial fidelity, and computational cost. Conclusion: Neural operators augmented with multimodal fusion can accurately predict full-field brain displacement from heterogeneous inputs. They offer inference times orders of magnitude faster than finite element solvers. This comparison provides guidance for selecting operator learning approaches in biomedical settings. 2025-09-26T01:48:27Z Anusha Agarwal Dibakar Roy Sarkar Somdatta Goswami http://arxiv.org/abs/2604.21747v1 OptoCENTAL: a standardised, bench-testing platform based on phantoms for validating optical systems aimed at clinical monitoring of the placenta 2026-04-23T14:54:52Z Optical imaging and spectroscopy solutions, such as near-infrared spectroscopy (NIRS) and diffuse optical tomography (DOT), have the potential to provide compact, bedside monitoring of the placenta in the clinic, thanks to recent advancements in miniaturisation and wireless wearability. This would provide neonatologist with continuous assessment of the pregnancy status in real-time, as well as tools to possibly predict delivery outcomes. We present here OptoCENTAL, a standardized platform based on multiple optical phantoms, from digital, through solid to liquid, for a comprehensive bench-testing, characterisation and validation of any photonics solution and instrumentation that aims at in vivo, clinical monitoring of the human placenta. Results: Exemplary applications of the OptoCENTAL platform on different types of optical systems, from wearable, continuous-wave devices to broadband and time-domain NIRS systems, demonstrate the flexibility of its procedures to be implemented with any setup, allowing users to compare performances across different solutions. The results also show the capability of OptoCENTAL to provide quantitative assessment of the major features required by any photonic solution for providing effective and efficient monitoring of the placenta, including basic instrument performances, quantification of monitoring accuracy, as well as depth sensitivity. OptoCENTAL represent the first-of-a-kind effort in standardising bench-testing and validation of optical imaging and spectroscopy methods in the framework of placental clinical applications, further advancing the translation of such modalities into the hospitals, as well as towards future certification and commercialisation of such technologies. 2026-04-23T14:54:52Z Luca Giannoni Uzair Hakim Fréderic Lange Musa Talati Darshana Gopal Angelos Artemiou Niccole Ranaei-Zamani Subhabrata Mitra Ilias Tachtsidis http://arxiv.org/abs/2604.21683v1 Flexible Piezoresistive Yarn Sensor for Human Physiological Signal Measurement 2026-04-23T13:47:29Z Continuous monitoring of physiological signals is essential for the early detection of health problems. A measurement system that ensures high sensitivity, accuracy, and user comfort is needed. In this study, we designed and optimized a flexible piezoresistive yarn (FPY) sensor to achieve a high sensitivity and wide working range for detecting physiological signals. The representative sensor design was constructed by applying an FPY bonding pattern, utilizing tightly arranged triangular patterns and using minimal FPY. The prototype sensor operates in two measurement modes, strain and pressure, and was evaluated for measuring neck motion, finger bending, respiratory signals, and arterial blood pressure (ABP) waveforms. A qualitative evaluation, performed by comparing the characteristics of the measurement results of each physiological signal with those from related studies, indicates a high similarity in its morphological characteristics. Then, a quantitative evaluation through baseline drift analysis demonstrates that the FPY sensor displays high measurement stability. The ABP waveform measurement shows the most stable baseline, with a mean absolute error (MAE) of $0.0051 \pm 0.0029$ in terms of baseline drift, using normalized values from 0 to 1. Based on our results, the prototype sensor can be used as an innovative solution for physiological signal monitoring and can be further enhanced for personalized healthcare and sports applications. 2026-04-23T13:47:29Z 11 pages, 8 figures; Preprint to be submitted to IEEE Access Rizal Maulana Ádám Rák Sándor Földi György Cserey http://arxiv.org/abs/2604.21636v1 A microwave super-resolution imaging approach towards breast cancer margin mapping 2026-04-23T12:53:09Z Accurate characterisation of margins in excised breast cancer tumours is critical to the success of surgical interventions, yet margin status is typically confirmed post-operatively using histopathology. Here we present a new approach to intraoperative margin assessment based on microwave single pixel imaging, demonstrating tissue phantom hydration mapping across large areas (~10 cm x 10 cm) at ~1 mm resolution. By leveraging the photo-induced change in microwave transparency of a silicon modulator placed under the sample, we map the microwave reflectivity and identify positive margins with deeply sub-wavelength resolution. We test the discriminatory capabilities of our approach using gelatine-based tumour phantoms with variations in water density representative of the margin and cancerous tissues of a resected tumour. We demonstrate the capability to identify, locate and quantify inadequate margins up to the typically targeted minimum thickness of 2 mm. Furthermore, using numerical modelling, we show that our approach is expected to be resilient to patient-specific tissue differences. Our technique has potential for future deployment as a real-time intraoperative tissue margin analysis tool. 2026-04-23T12:53:09Z 15 pages, 7 figures including supplementary Harry Penketh Sonal Saxena Michal Mrnka Cameron P. Gallagher Caitlin Lloyd Diksha Garg Christopher R. Lawrence Nicholas E. Grant John D. Murphy David B. Phillips Ian R. Hooper Nick Stone Euan Hendry http://arxiv.org/abs/2604.21056v1 Radiomics-Guided Vision Transformers for Survival Analysis 2026-04-22T19:59:20Z Vision Transformers (ViTs) have shown strong empirical performance on high-dimensional medical imaging data, yet their behavior under survival objectives and the interpretability of their attention mechanisms remain poorly understood. Under shallow ViTs, we design controlled experiments showing that token-level attention dynamics can recover outcome-relevant regions and that attention-based thresholding enables effective token pruning, improving both interpretability and predictive performance. We also study pretrained deep ViTs for survival analysis and propose a radiomics-guided hybrid model that integrates pixel-based embeddings with interpretable radiomic features through a multimodal Cox framework and contrastive alignment. Applied to a COVID-19 chest X-ray cohort with a composite ICU admission or mortality endpoint, the proposed approach achieves competitive discrimination while providing clinically meaningful attention maps and feature-group importance. 2026-04-22T19:59:20Z Qiyuan Shi Yi Li http://arxiv.org/abs/2408.11471v2 Learning-based Linear Inversion for Quantitative Pulse-Echo Speed-of-Sound Imaging 2026-04-22T16:01:19Z Computed ultrasound tomography in echo mode generates maps of tissue speed of sound (SoS) from the shift of echoes when detected under varying steering angles. It solves a linearized inverse problem that requires regularization to complement the echo shift data with a priori constraints. Spatial gradient regularization has been used to enforce smooth solutions, but SoS estimates were found to be biased depending on tissue layer geometry. Here, we propose to train a linear operator to minimize SoS errors on average over a large number of random tissue models that sample the distribution of geometries and SoS values expected in vivo. In an extensive simulation study on liver imaging, we demonstrate that biases are strongly reduced, with residual biases being the result of a partial non-linearity in the actual physical problem. This approach can either be applied directly to echo-shift data or to the SoS maps estimated with gradient regularization, where the former shows slightly better performance, but the latter is computationally more efficient. Experimental phantom results confirm the transferability of our results to real ultrasound data. 2024-08-21T09:38:51Z This work has been submitted to the IEEE for possible publication Parisa Salemi Yolgunlu University of Bern Jules Blom University of Twente Naiara Korta Martiartu Ecole polytechnique fédérale de Lausanne Michael Jaeger University of Bern http://arxiv.org/abs/2604.20939v1 Deep Reinforcement Learning for Optimizing Angle Selection and Dose Allocation in CT Reconstruction 2026-04-22T13:59:05Z Traditional X-ray computed tomography (CT) scanning strategies typically select projection angles uniformly and allocate dose equally. In practice, however, CT scans often need to be fast, radiation-efficient, and adaptive. Sparse-view tomography addresses these requirements by reducing both the number of angles and the total dose budget. Under such constraints, angle selection and dose allocation should be information-driven, with more dose assigned to informative directions. To this end, we propose a dose-aware acquisition and reconstruction framework that combines a PWLS-PnP reconstruction backbone with an RL-based strategy for adaptive angle selection, explicitly accounting for angle-dependent photon statistics. Numerical experiments show that the proposed approach improves overall reconstruction quality and enhances defect detectability compared with conventional strategies, particularly when only a small number of projections or a constrained dose budget is available. 2026-04-22T13:59:05Z Tianyuan Wang Daniël M. Pelt Felix Lucka Tristan van Leeuwen K. Joost Batenburg http://arxiv.org/abs/2403.18151v2 Automated Description Generation of Cytologic Findings for Lung Cytological Images Using a Pretrained Vision Model and Dual Text Decoders: Preliminary Study 2026-04-22T00:22:39Z Objective: Cytology plays a crucial role in lung cancer diagnosis. Pulmonary cytology involves cell morphological characterization in the specimen and reporting the corresponding findings, which are extremely burdensome tasks. In this study, we propose a technique to generate cytologic findings from for cytologic images to assist in the reporting of pulmonary cytology. Methods: For this study, 801 patch images were retrieved using cytology specimens collected from 206 patients; the findings were assigned to each image as a dataset for generating cytologic findings. The proposed method consists of a vision model and dual text decoders. In the former, a convolutional neural network (CNN) is used to classify a given image as benign or malignant, and the features related to the image are extracted from the intermediate layer. Independent text decoders for benign and malignant cells are prepared for text generation, and the text decoder switches according to the CNN classification results. The text decoder is configured using a Transformer that uses the features obtained from the CNN for generating findings. Results: The sensitivity and specificity were 100% and 96.4%, respectively, for automated benign and malignant case classification, and the saliency map indicated characteristic benign and malignant areas. The grammar and style of the generated texts were confirmed correct, achieving a BLEU-4 score of 0.828, reflecting high degree of agreement with the gold standard, outperforming existing LLM-based image-captioning methods and single-text-decoder ablation model. Conclusion: Experimental results indicate that the proposed method is useful for pulmonary cytology classification and generation of cytologic findings. 2024-03-26T23:32:29Z This paper has been published in Cytopathology (2025) Atsushi Teramoto Ayano Michiba Yuka Kiriyama Tetsuya Tsukamoto Kazuyoshi Imaizumi Hiroshi Fujita 10.1111/cyt.13474 http://arxiv.org/abs/2603.24922v2 Robust Multicenter CT Radiogenomics for Dual EGFR and KRAS Prediction in Lung Cancer with Stability-Aware Modeling and SHAP Interpretation 2026-04-21T21:38:22Z Accurate identification of EGFR and KRAS mutations is essential for precision therapy in non-small cell lung cancer (NSCLC), but tissue genotyping is invasive and may not capture tumor heterogeneity. CT-based radiogenomics offers a noninvasive alternative, although generalization across centers remains challenging. We benchmarked handcrafted radiomics features (HRF), deep feature representations (DFR), and their fusion for three-class mutation prediction (wild-type, KRAS-mutant, and EGFR-mutant) with external testing. We curated 1,023 thoracic CT scans from 12 public datasets across more than 20 centers, including 136 patients with EGFR/KRAS labels. IBSI-compliant HRFs were extracted with standardized preprocessing, and DFRs were derived using PySERA. HRF-only, DFR-only, and fused HRF+DFR pipelines were evaluated using five-fold cross-validation and external testing. A semi-supervised pseudo-labeling strategy leveraged unlabeled CT scans, and SHAP supported interpretability. In external testing, HRF-based models generalized best, achieving AUC 0.77 +/- 0.07 and accuracy 0.77 +/- 0.00. DFR-based models showed a larger drop from cross-validation to external testing, with best external AUC around 0.57 +/- 0.05. Fusion improved robustness over DFR-only models but did not consistently outperform HRFs. SHAP identified morphology- and heterogeneity-related radiomic phenotypes as key predictors. Standardized handcrafted radiomics within a multicenter semi-supervised framework may provide a generalizable and interpretable approach for CT-based EGFR/KRAS stratification. 2026-03-26T01:23:14Z Somayeh Sadat Mehrnia Fatemeh Razavi Helia Abedini Niloofar Rahimi Arman Rahmim Mohammad Salmanpour http://arxiv.org/abs/2512.05791v2 Fast and Robust Diffusion Posterior Sampling for MR Image Reconstruction Using the Preconditioned Unadjusted Langevin Algorithm 2026-04-21T16:54:33Z Purpose: The Unadjusted Langevin Algorithm (ULA) in combination with diffusion models can generate high quality MRI reconstructions with uncertainty estimation from highly undersampled k-space data. However, sampling methods such as diffusion posterior sampling (DPS) or likelihood annealing suffer from long reconstruction times and the need for parameter tuning. The purpose of this work is to develop a robust sampling algorithm with fast convergence. Theory and Methods: In the reverse diffusion process used for sampling the posterior, the exact likelihood is multiplied with the diffused prior at all noise scales. To overcome the issue of slow convergence, preconditioning is used. The method is trained on fastMRI data and tested on retrospectively undersampled brain data of a healthy volunteer. Results: For posterior sampling in Cartesian and non-Cartesian accelerated MRI the new approach outperforms annealed sampling and DPS in terms of reconstruction speed and sample quality. Conclusion: The proposed exact likelihood with preconditioning enables rapid and reliable posterior sampling across various MRI reconstruction tasks without the need for parameter tuning. 2025-12-05T15:17:29Z Submitted to Magnetic Resonance in Medicine Moritz Blumenthal Tina Holliber Jonathan I. Tamir Martin Uecker 10.1002/mrm.70416 http://arxiv.org/abs/2604.19407v1 Optimized encoding point distributions for efficient single-point imaging 2026-04-21T12:35:27Z Purpose: Quasi-random Sobol-based sampling schemes exhibit deterministic structural artifacts when aggressively undersampled, particularly at low encoding densities required for accelerated 2D SPI/CSI. To address these limitations, two advanced undersampling strategies are investigated to mitigate deterministic behavior, improving image quality for time-constrained applications such as hyperpolarized MRI. Methods: An optimized Sobol sequence-derived point distribution with Heaviside-type density gradient center oversampling served as the initial sampling pattern. Undersampling was performed using two point-reduction algorithms: radius-adaptive stochastic undersampling (RAST), which applies a geometric, radius-dependent minimum-distance criterion, and Bayesian Information Gain Optimization (BINGO), that removes points based on their information gain to the reconstructed image. Phantom experiments were conducted on a 3 T clinical MRI system using up to 16-fold undersampling. Image quality was quantified using a performance score derived from RMSE, SSIM, and HFEN. Results: Both RAST and BINGO outperformed deterministic undersampling across all metrics. RAST achieved highest and most robust performance, with improvements up to 238% in the averaged metric score, while BINGO yielded improvements of 133% across matrix resolutions. Conclusion: The proposed strategies effectively reduce the number of encoding points in low-discrepancy 2D SPI point distributions while maintaining image quality under strong acceleration. RAST provides superior metric performance, whereas BINGO offers broad applicability, including suitability for non-linear encoding fields. These approaches support rapid acquisition workflows required for real-time and hyperpolarized applications. 2026-04-21T12:35:27Z 12 pages, 5 figures Fabian Bschorr Pia Gebhard Tobias Speidel Volker Rasche http://arxiv.org/abs/2604.19289v1 Corneal deformation mapping and FE-based strain analysis via digital image correlation: biomechanical changes after CXL and laser refractive surgery 2026-04-21T09:54:31Z Accurate assessment of corneal mechanical properties is critical for understanding ocular biomechanics, predicting refractive surgery outcomes, and optimizing cross-linking (CXL) treatments. Conventional uniaxial tensile test is limited by non-physiological boundary conditions and simplified stress distributions. Inflation testing more closely reproduces the in vivo stress state but has traditionally lacked full-field deformation mapping. In this work, we present an integrated experimental-computational protocol combining inflation testing of freshly enucleated porcine eyes with high-resolution three-dimensional digital image correlation (3D-DIC). Fifteen corneas were analyzed across three cohorts: (i) de-epithelialized controls, (ii) CXL-treated (standard Dresden protocol), and (iii) anterior stromal ablation via femtosecond laser. Samples were subjected to controlled intraocular pressure (IOP) elevations up to 40 mmHg. The 3D-DIC approach provided dense, pointwise displacement and strain maps across the anterior surface, successfully quantifying the localized stiffening effects of CXL and the increased compliance induced by stromal ablation. These full-field kinematic data were integrated into a membrane-theory finite element framework to resolve principal in-plane strains, that were used for subsequent inverse modeling to derive anisotropic hyperelastic parameters of porcine corneal tissue. Overall, the method establishes an end-to-end route from physiologic loading to full-field strain mapping and constitutive parameter identification, enabling quantitative evaluation of treatment-induced biomechanical changes in the cornea. 2026-04-21T09:54:31Z Benedetta Fantaci Alejandro Frechilla Matteo Frigelli Philippe Büchler Sabine Kling Begoña Calvo http://arxiv.org/abs/2604.18807v1 VOLT: Volumetric Wide-Field Microscopy via 3D-Native Probabilistic Transport 2026-04-20T20:24:43Z Three-dimensional (3D) wide-field fluorescence microscopy is a widely used modality for volumetric imaging, but suffers from characteristic out-of-focus blur. Existing reconstruction methods either struggle to operate on high-dimensional volumes or fail to provide credibility characterization of the reconstruction. In this work, we introduce Volumetric Transport (VOLT), a 3D-native probabilistic framework for wide-field fluorescence microscopy reconstruction. VOLT combines a transport-based formulation that maps degraded measurements to clean volumes via stochastic interpolants with a 3D-native anisotropic network that separates lateral and axial processing. This design operates directly in voxel space and achieves improved scalability to large volumes without relying on slice-wise approximations. We develop both stochastic (SDE) and deterministic (ODE) variants within the same framework. We validate VOLT on simulated wide-field microscopy datasets. Our results show that VOLT significantly improves reconstruction quality in both lateral and axial directions while providing voxel-wise credibility estimates. 2026-04-20T20:24:43Z Yetao He Wenhan Guo Deliang Wei Evan Bel Ji Yi Yu Sun http://arxiv.org/abs/2604.17361v1 3D-DXA Cortical and Trabecular Parameters: Agreement Between Hologic Densitometers in Clinical Practice 2026-04-19T10:16:05Z Background: Three-dimensional dual-energy X-ray absorptiometry reconstructs three-dimensional maps of the proximal femur's density distribution from standard hip scans, enabling the estimation of trabecular and cortical bone parameters. The aim of this study was to assess the agreement of these three-dimensional cortical and trabecular femur parameters across different series and models of Hologic densitometers. Methodology: The study cohort was composed of 103 women and men recruited from four clinical centers in Spain and France. Subjects had duplicated hip scans using different Hologic scanners from the Horizon, Discovery, and QDR4500 series. Analyses were performed using 3D-Shaper software. Inter-scanner agreement was evaluated using Deming regression and Bland-Altman analysis. Results: The parameters demonstrated strong inter-device agreement across all clinical centers and scanner models, with coefficients of determination greater than 0.91. Absolute biases were less than 2.5 mg$/$cm$^3$ for integral volumetric bone mineral density, less than 2.9 mg$/$cm$^3$ for trabecular volumetric bone mineral density, and less than 1.7 mg$/$cm$^2$ for cortical surface bone mineral density. No statistically significant bias was found between parameters obtained from different scanners. Furthermore, the observed bias was lower than the expected least significant change, indicating that inter-scanner variability across these devices is not clinically significant. Conclusions: This study demonstrated excellent agreement for standard and three-dimensional derived bone parameters at the hip across Hologic densitometers. These findings support their suitability for clinical use. 2026-04-19T10:16:05Z 17 pages, 2 tables, 4 figures Marta I. Bracco Jorge Malouf Laurent Maimoun Xavier Nogues Jean Paul Roux François DuBoeuf Ludovic Humbert http://arxiv.org/abs/2604.16981v1 Light-Adapted Electroretinogram and Oscillatory Potentials (LEOPs) Dataset for Autism Spectrum Disorder and Typically Developing Individuals 2026-04-18T12:48:28Z The LEOPs (Light-ERG-Oscillatory Potentials) dataset provides light-adapted (LA) electroretinogram (ERG) and Oscillatory Potentials (OPs) waveforms for typically developing Control, Autism Spectrum Disorder (ASD) and ASD + Attention Deficit Hyperactivity Disorder (ADHD) childhood and adolescent populations. The ERGs were recorded in the Right And Left eyes with skin electrodes using the handheld RETeval device at two sites in Australia and the United Kingdom. The LEOPs dataset includes 5309 single flash ERG and 4434 OPs waveforms as well as images selected from each participant showing the position of the skin electrode. The LEOPs dataset is constructed from recordings using a 9 step randomized flash series from $-0.37$ to $1.20$~$Td.s$, a 2 step at 113 and 446 $Td.s$ flash strengths (2500 Control, 1730 ASD and 451 ASD + ADHD samples), as well as the $85$~$Td.s$ (Light Adapted 3 $cd.s.m^{-2}$ (LA3)) equivalent International Society of Clinical Electrophysiology of Vision (ISCEV) Standard flash with 435 Control, 176 ASD and 37 ASD + ADHD waveform samples. Code for the stimulus is provided along with participant demographics, date and time of testing, and where available diagnostic scores for the ASD and ASD + ADHD groups, alongside iris color, electrode position with image files and time domain values for the ERG and summed values for the OPs. The repository contains excel file, exported JSON files on the patient level that are more suitable for machine learning tasks, images of electrode position for each recording and the protocol files for use with the RETeval. 2026-04-18T12:48:28Z Paul A. Constable Dorothy A. Thompson Irene O. Lee Lynne Loh Aleksei Zhdanov Mikhail Kulyabin Andreas Maier