https://arxiv.org/api/WT5e6tuduHjAybzf2ms6ljms6bI 2026-04-09T12:49:36Z 8808 195 15 http://arxiv.org/abs/2602.07760v1 The Development of a Preclinical Alpha Irradiation Platform with Versatile Control of Dose, Dose Rate, and Spatiotemporal Irradiation Patterns 2026-02-08T01:33:57Z Objectives. This study develops and validates a vacuum-based alpha irradiation platform to support preclinical radiobiology. We aim to demonstrate precise, independent control over incident energy, fluence rate, and spatiotemporal patterns, which are critical to the mechanisms underlying targeted alpha therapies and low-dose risk assessments. Approach. A vacuum-based system with a radioactive alpha source was designed and fabricated. The platform provides independent modulation of: (i) temporal patterns via a programmable gate valve; (ii) fluence rate across two orders of magnitude by varying source-to-aperture distance (57 to 381 mm); (iii) incident energy (0 to 4.6 MeV) using adjustable absorption layers; and (iv) spatial distributions via a 3D motion stage. Temporal precision was assessed via synchronized audio-electronic recordings. Fluence rates and energies were validated using CR-39 detectors and Monte Carlo (MC) simulations. Spatial precision was verified through programmed continuous and discrete trajectories. Main results. Validation experiments demonstrated high system fidelity. Measured irradiation durations deviated from programmed values by less than 0.3 s. Measured and computed fluence rates agreed within 3%. For energy validation, CR-39 track diameters matched MC model predictions within one standard deviation. Recorded spatial patterns and dimensions aligned well with programmed trajectories. Significance. We successfully validated a versatile vacuum-based platform that overcomes energy-degradation constraints of gas-filled systems. By providing multi-parametric control over alpha-particle delivery, this system enables systematic investigation into how energy, dose rate, and spatiotemporal patterns influence radiobiological responses. This platform is poised to optimize targeted alpha therapies and refine radiation protection frameworks. 2026-02-08T01:33:57Z Harsh Arya Joshua Rajan Varghese Chirayath Mainul Arbar Awat Lotfihagh Sitmukhambetov Satzhan Yan Chang Alex Weiss Zui Pan Yujie Chi http://arxiv.org/abs/2602.07580v1 First ex-vivo positronium imaging of tissues with modular J-PET scanner using $^{44}$Sc radionuclide 2026-02-07T15:10:03Z This study presents the first ex-vivo positronium imaging of human tissues using the modular J-PET scanner with the $^{44}$Sc radionuclide. The $^{44}$Sc isotope was produced via the $^{44}$Ca(p, n)$^{44}$Sc nuclear reaction and used to perform positronium imaging of phantom composed of human adipose tissue, cardiac myxoma tissue, thrombi blood clot, and also porous polymer XAD4, and a certified reference material (CRM) made from fused silica. The experiment demonstrates the suitability of $^{44}$Sc as a positron source for positronium imaging. The performance of J-PET for positronium imaging with $^{44}$Sc was validated by proper reconstruction of the mean orthopositronium lifetime for CRM material and XAD-4 polymer. The mean ortho-positronium (oPs) lifetimes determined for adipose tissue, cardiac myxoma tissues and thrombi were consistent with results of previous experiments. The study highlights the potential $^{44}$Sc radionuclide for positronium lifetime imaging (PLI). 2026-02-07T15:10:03Z to be published in Zeitschrift für Medizinische Physik Karol Kubat Manish Das Sushil Sharma Ermias Y. Beyene Aleksander Bilewicz Jarosław Choiński Neha Chug Catalina Curceanu Eryk Czerwiński Jakub Hajduga Sharareh Jalali Krzysztof Kacprzak Tevfik Kaplanoglu Łukasz Kapłon Kamila Kasperska Aleksander Khreptak Grzegorz Korcyl Tomasz Kozik Deepak Kumar Sumit Kumar Kundu Anoop Kunimmal-Venadan Bartosz Leszczyński Edward Lisowski Filip Lisowski Justyna Mędrala-Sowa Simbarashe Moyo Wiktor Mryka Szymon Niedźwiecki Anand Pandey Piyush Pandey Szymon Parzych Alessio Porcelli Bartłomiej Rachwał Martin Rädler Magdalena Skurzok Anna Stolarz Tomasz Szumlak Pooja Tanty Keyvan Tayefi Ardebili Satyam Tiwari Kavya Valsan Eliyan Rafał Walczak Paweł Moskal Ewa Ł. Stępień http://arxiv.org/abs/2601.22192v2 Chitosan/alginate bionanocomposites adorned with mesoporous silica nanoparticles for bone tissue engineering 2026-02-07T10:25:17Z The regeneration of oral and craniofacial bone defects ranging from minor periodontal and peri-implant defects to large and critical lesions imposes a substantial global health burden. Conventional therapies are associated with several limitations, highlighting the development of a unique treatment strategy, such as tissue engineering. A well-designed scaffold for bone tissue engineering should possess biocompatibility, biodegradability, mechanical strength, and osteoconductivity. For this purpose, mesoporous silica nanoparticles (MSNs) were synthesized and incorporated at different ratios (10, 20, and 30%) into alginate/chitosan (Alg/Chit)-based porous composite scaffolds fabricated through the freeze-drying method. The MSN incorporation significantly improved the mechanical strength of the scaffolds while showing a negligible decreasing effect on the porosity. All of the samples showed desirable swelling behaviors, which is beneficial for cell attachment and proliferation. The MSN-containing scaffolds indicated a decreased hydrolytic degradation in an MSN percentage-dependent manner. The fabricated scaffolds did not depict cytotoxic characteristics. The Alg/Chit/MSN30 scaffolds not only showed noncytotoxic properties, but also increased the cell viability significantly compared to the control group. The biomineralization properties of the MSN-containing nanocomposite scaffolds were significantly higher than the Alg/Chit composite, suggesting the potential of these nanoparticles for bone tissue engineering applications. Taken together, it is concluded that the Alg/Chit/ MSN30 scaffolds are considerable substances for bone tissue regeneration, and MSN has a great tissue engineering potential in addition to its extensive biomedical applications. 2026-01-29T08:36:43Z Journal of Nanostructure in Chemistry, 13 (2023) 389-403 Satar Yousefiasl Hamed Manoochehri Pooyan Makvandi Saeid Afshar Erfan Salahinejad Pegah Khosraviyan Massoud Saidijam Sara Soleimani Asl Esmaeel Sharifi 10.1007/s40097-022-00507-z http://arxiv.org/abs/2602.07162v1 High-fidelity 3D multi-slab diffusion MRI using Slab-shifting for Harmonized 3D Acquisition and Reconstruction with Profile Encoding Networks (SHARPEN) 2026-02-06T20:03:25Z Three-dimensional (3D) multi-slab imaging is a promising approach for high-resolution in vivo diffusion MRI (dMRI) due to its compatibility with short TR (1-2 s), providing optimal signal-to-noise ratio (SNR) efficiency. A major challenge, however, is slab boundary artifacts arising from non-ideal slab-selective RF excitation. Non-rectangular slab profiles reduce signal intensity at slab boundaries, while profile overlap across adjacent slabs introduces inter-slab crosstalk, where repeated excitation shortens the local TR and limits T1 recovery. To mitigate slab boundary artifacts without increasing scan time, we build on slab profile encoding and propose Slab-shifting for Harmonized 3D Acquisition and Reconstruction with Profile Encoding Networks (SHARPEN). For different diffusion directions, SHARPEN applies inter-volume field-of-view shifts along the slice direction to provide complementary slab profile encoding without prolonging acquisition. Slab profiles are estimated using a lightweight self-supervised neural network that exploits consistency across shifted acquisitions and known physical properties of slab profiles and diffusion images, and corrected images are reconstructed accordingly. SHARPEN was validated using simulated and prospectively acquired high-resolution in vivo data and demonstrates accurate slab profile estimation and robust boundary artifact correction, even in the presence of inter-volume motion. SHARPEN does not require high-quality reference training data and supports subject-specific training. Its efficient GPU-based implementation delivers faster and more accurate correction than NPEN, yielding slice-wise quantitative profiles that closely match those from reference 2D acquisitions. SHARPEN enables high-quality dMRI at 0.7 mm isotropic resolution on a 3T clinical scanner, highlighting its potential to advance submillimeter dMRI for neuroscience research. 2026-02-06T20:03:25Z 26 pages, 11 figures + supplementary info Ziyu Li Karla L. Miller Wenchuan Wu http://arxiv.org/abs/2504.19175v2 A tissue-informed deep learning-based method for positron range correction in preclinical 68Ga PET imaging 2026-02-06T09:47:17Z Positron range (PR) limits spatial resolution and quantitative accuracy in PET imaging, particularly for high-energy positron-emitting radionuclides like 68Ga. We propose a deep learning method using 3D residual encoder-decoder convolutional neural networks (3D RED-CNNs), incorporating tissue-dependent anatomical information through a u-map-dependent loss function. Models were trained with realistic simulations and, using initial PET and CT data, generated positron range corrected images. We validated the models in simulations and real acquisitions. Three 3D RED-CNN architectures, Single-channel, Two-channel, and DualEncoder, were trained on simulated PET datasets and evaluated on synthetic and real PET acquisitions from 68Ga-FH and 68Ga-PSMA-617 mouse studies. Performance was compared to a standard Richardson-Lucy-based positron range correction (RL-PRC) method using metrics such as mean absolute error (MAE), structural similarity index (SSIM), contrast recovery (CR), and contrast-to-noise ratio (CNR). CNN-based methods achieved up to 19 percent SSIM improvement and 13 percent MAE reduction compared to RL-PRC. The Two-Channel model achieved the highest CR and CNR, recovering lung activity with 97 percent agreement to ground truth versus 77 percent for RL-PRC. Noise levels remained stable for CNN models (approximately 5.9 percent), while RL-PRC increased noise by 5.8 percent. In preclinical acquisitions, the Two-Channel model achieved the highest CNR across tissues while maintaining the lowest noise level (9.6 percent). Although no ground truth was available for real data, tumor delineation and spillover artifacts improved with the Two-Channel model. These findings highlight the potential of CNN-based PRC to enhance quantitative PET imaging, particularly for 68Ga. Future work will improve model generalization through domain adaptation and hybrid training strategies. 2025-04-27T09:34:25Z Submitted to EJNMMI Physics Nerea Encina-Baranda Nuclear Physics Group, EMFTEL and IPARCOS, University Complutense of Madrid Instituto de Investigación Sanitaria, Hospital Clínico San Carlos Robert J. Paneque-Yunta Nuclear Physics Group, EMFTEL and IPARCOS, University Complutense of Madrid Instituto de Investigación Sanitaria, Hospital Clínico San Carlos Javier Lopez-Rodriguez Nuclear Physics Group, EMFTEL and IPARCOS, University Complutense of Madrid Instituto de Investigación Sanitaria, Hospital Clínico San Carlos Edwin C. Pratt Molecular Pharmacology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USA Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USA Department of Pharmacology, Weill Cornell Graduate School, 1300 York Avenue, New York, 10065, New York, USA Trong Nghia Nguyen Molecular Pharmacology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USA Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USA Department of Pharmacology, Weill Cornell Graduate School, 1300 York Avenue, New York, 10065, New York, USA Jan Grimm Molecular Pharmacology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USA Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, 10065, New York, USA Department of Pharmacology, Weill Cornell Graduate School, 1300 York Avenue, New York, 10065, New York, USA Alejandro Lopez-Montes Department of Nuclear Medicine, Bern University Hospital, Freiburgstrasse 4, Bern, 3010, Switzerland Joaquin L. Herraiz Nuclear Physics Group, EMFTEL and IPARCOS, University Complutense of Madrid Instituto de Investigación Sanitaria, Hospital Clínico San Carlos http://arxiv.org/abs/2510.11670v2 Collagen and myocyte interplay in cardiac volume overload: a multi-constituent growth and remodeling framework 2026-02-06T01:46:32Z Hearts subjected to volume overload (VO) are prone to detrimental anatomical and functional changes in response to elevated mechanical loading, ultimately leading to heart failure. Experimental findings now emphasize that organ-scale changes following VO cannot be explained by myocyte growth alone, as traditionally proposed in the literature. Collagen degradation, in particular, has been associated with VO and assumed to play a central role in both its acute and chronic stages. This hypothesis, however, remains to be substantiated by comprehensive mechanistic evidence, and each constituent contribution to myocardial growth and remodeling (G&R) processes is yet to be quantified. In this work, we present a multi-constituent G&R framework that integrates a mixture-based constitutive model within the kinematic growth formulation. This framework enables us to mechanistically assess the relative contributions of collagen and myocyte changes to alterations in tissue properties, ventricular dimensions, and growth phenotype. Our numerical results confirm that collagen remodeling affects the passive mechanical response of the myocardium, whereas myocytes predominantly influence the extent and phenotype of VO-induced growth. Importantly, collagen degradation exacerbates myocyte hypertrophy, revealing a synergistic interplay that accelerates the left ventricular eccentric growth and thereby promotes systolic dysfunction. This work constitutes an important step towards an integrated characterization of the early compensatory stages of VO-induced cardiac G&R. 2025-10-13T17:43:08Z Ludovica Maga Mathias Peirlinck Lise Noël http://arxiv.org/abs/2602.05908v1 Self-Portrait of the Focusing Process in Speckle: III. Tailoring Complex Spatio-Temporal Focusing Laws To Overcome Reverberations in Reflection Imaging 2026-02-05T17:24:18Z This is the third article in a series of three dealing with the exploitation of speckle for imaging purposes. In complex media, a fundamental limit is the multiple scattering phenomenon that completely blurs the imaging process in depth. Matrix imaging can provide a relevant framework for solving this problem. As it proved to be an adequate tool for probing reverberations in speckle [E. Giraudat et al., Part I], we will show how it can be used to tailor complex spatio-temporal focusing laws to monitor the interference between the multiply-reflected paths and the ballistic component of the wave-field. To do so, we extend the distortion matrix concept to the frequency domain. An iterative phase reversal process operated from the space-time Fourier space is then used to compensate for reverberations and optimize both the axial and transverse resolution of the confocal image. Here, we first present an experimental proof-of-concept consisting in imaging a tissue-mimicking phantom through a reverberating plate before outlining the potential and the limits of this strategy for transcranial ultrasound and beyond. 2026-02-05T17:24:18Z 29 pages, 8 figures, 2 tables Elsa Giraudat Flavien Bureau William Lambert Mathias Fink Alexandre Aubry http://arxiv.org/abs/2602.05907v1 Self-Portrait of the Focusing Process in Speckle: I. Spatio-Temporal Imaging of Wave Packets in Complex Media 2026-02-05T17:23:23Z This is the first article in a series of three dealing with the exploitation of speckle for imaging purposes. Speckle is the complex interference wave-field produced by a random distribution of un-resolved scatterers. In this paper, we show how these scatterers can be used as virtual microphones to monitor the spatio-temporal propagation of a wave-packet inside the medium. To do so, the concept of matrix imaging is particularly useful. It consists in decoupling the location of the transmitted and received focal spots in a standard beamforming process. By scanning the wave-field with the output focal spot that then acts as a virtual transducer, one can image the spatio-temporal evolution of the wave-packet inside the medium. This unique observable will allow us to highlight the imperfections of the focusing process, in particular the defocus and reverberations induced by a strong aberrating layer. As a proof-of-concept, we will consider ultrasound experiments on tissue-mimicking phantoms. In the next two papers, we will show how this observable can be leveraged to compensate for these phenomena that hamper wave focusing and imaging in all fields of wave physics. Our method is indeed broadly applicable to different types of waves beyond ultrasound for which multi-element technology allows a reflection matrix to be measured. 2026-02-05T17:23:23Z 39 pages, 11 figures, 1 table Elsa Giraudat Flavien Bureau William Lambert Mathias Fink Alexandre Aubry http://arxiv.org/abs/2409.13901v2 Self-Portrait of the Focusing Process in Speckle: II. Gouy Phase Shift for Defocus Correction and Pixel Depth Reassignment 2026-02-05T17:12:43Z This is the second article in a series of three dealing with the exploitation of speckle for aberration correction and reverberation compensation in reflection imaging. When probing heterogeneous media with waves, we have to cope with multi-scale fluctuations of the wave velocity. On the one hand, short-scale heterogeneities induce back-scattered echoes whose random interference generate a speckle pattern on the beamformed image. On the other hand, large-scale fluctuations of the wave-velocity can distort the focused wave-fronts, resulting in aberrations on the same image. In this paper, we show how the self-portrait of the wave evolves as a function of the speed-of-sound model. Strikingly, a Gouy phase shift is observed when the speed-of-sound model is optimal. This particularly sensitive feature enables: (i) an optimization of the speed-of-sound model for each pixel of the image; (ii) a local and fine compensation of defocus across the field-of-view, thereby compensating for most aberrations in the image. Experiment in a tissue-mimicking phantom and numerical simulations are first presented to validate our method. It is then applied to in-vivo liver data of a difficult-to-image patient. The speed-of-sound optimization allows an axial compensation of aberrations and a depth-reassignment of each singly-scattered echo to the actual position of the associated scatterer. As distance measurement is often critical for diagnosis, such a wave speed optimization can be crucial for ultrasound but also for any other imaging methods based on the principle of echo-location. 2024-09-20T21:05:51Z 43 pages, 8 figures, 3 tables Flavien Bureau Emma Brenner Naiara Korta Martiartu Elsa Giraudat Arthur Le Ber William Lambert Louis Carmier Aymeric Guibal Mathias Fink Alexandre Aubry http://arxiv.org/abs/2602.07060v1 U-Net Based Image Enhancement for Short-time Muon Scattering Tomography 2026-02-05T10:11:15Z Muon Scattering Tomography (MST) is a promising non-invasive inspection technique, yet the practical application of short-time MST is hindered by poor image quality due to limited muon flux. To address this limitation, we propose a U-Net-based framework trained on Point of Closest Approach (PoCA) images reconstructed with simulation MST data to enhance image quality. When applied to experimental MST data, the framework significantly improves image quality, increasing the Structural Similarity Index Measure (SSIM) from 0.7232 to 0.9699 and decreasing the Learned Perceptual Image Patch Similarity (LPIPS) from 0.3604 to 0.0270. These results demonstrate that our method can effectively enhance low-statistics MST images, thereby paving the way for the practical deployment of short-time MST. 2026-02-05T10:11:15Z Haochen Wang Pei Yu Liangwen Chen Weibo He Yu Zhang Yuhong Yu Xueheng Zhang Lei Yang Zhiyu Sun http://arxiv.org/abs/2602.05453v1 Towards Segmenting the Invisible: An End-to-End Registration and Segmentation Framework for Weakly Supervised Tumour Analysis 2026-02-05T08:55:26Z Liver tumour ablation presents a significant clinical challenge: whilst tumours are clearly visible on pre-operative MRI, they are often effectively invisible on intra-operative CT due to minimal contrast between pathological and healthy tissue. This work investigates the feasibility of cross-modality weak supervision for scenarios where pathology is visible in one modality (MRI) but absent in another (CT). We present a hybrid registration-segmentation framework that combines MSCGUNet for inter-modal image registration with a UNet-based segmentation module, enabling registration-assisted pseudo-label generation for CT images. Our evaluation on the CHAOS dataset demonstrates that the pipeline can successfully register and segment healthy liver anatomy, achieving a Dice score of 0.72. However, when applied to clinical data containing tumours, performance degrades substantially (Dice score of 0.16), revealing the fundamental limitations of current registration methods when the target pathology lacks corresponding visual features in the target modality. We analyse the "domain gap" and "feature absence" problems, demonstrating that whilst spatial propagation of labels via registration is feasible for visible structures, segmenting truly invisible pathology remains an open challenge. Our findings highlight that registration-based label transfer cannot compensate for the absence of discriminative features in the target modality, providing important insights for future research in cross-modality medical image analysis. Code an weights are available at: https://github.com/BudhaTronix/Weakly-Supervised-Tumour-Detection 2026-02-05T08:55:26Z Accepted for AIBio at ECAI 2025 Artificial Intelligence for Biomedical Data, AIBIO 2025, CCIS 2696, pp 229-242, 2026 Budhaditya Mukhopadhyay Chirag Mandal Pavan Tummala Naghmeh Mahmoodian Andreas Nürnberger Soumick Chatterjee 10.1007/978-3-032-17216-7_18 http://arxiv.org/abs/2602.05077v1 Laterally Oscillating Trajectory for Undersampling Slices: LOTUS 2026-02-04T21:52:55Z Purpose: While spiral sampling offers SNR advantages for diffusion MRI, its acceleration with simultaneous multislice remains relatively unexplored. This study introduces Laterally Oscillating Trajectory for Undersampling Slices (LOTUS), which is a 3D spiral-like k-space trajectory that aims to minimize g-factor via controlled incoherent aliasing. To aid in validation, we also introduce a robust method to estimate g-factor for iterative non-Cartesian reconstructions. Methods: Simulated data sampling of a numerical phantom was performed using LOTUS and several acquisition schemes proposed by others to quantitatively compare the resulting image quality when compared to a known ground truth. Diffusion-weighted in vivo brain data from two subjects was acquired with two in-plane acceleration factors (2x and 4x), and two slice acceleration factors (2x and 4x). Estimated g-factor maps and fractional anisotropy maps were calculated to quantitatively and qualitatively compare trajectory performance. For both simulation and in vivo, reconstructions both with and without compressed sensing were utilized. Results: Simulations generally showed decreased g-factor (20%-31%, depending on trajectory, at highest undersampling rate) and improved reconstruction accuracy (mean-square error, structural similarity index, and entropy metrics) for LOTUS compared to the other trajectories. The in vivo acquisitions demonstrated g-factor benefits and qualitative image quality improvements that mirrored the simulation results. For both simulation and in vivo, improvements for LOTUS increased for higher numbers of simultaneous slices. Conclusion: By enabling higher rates of slice acceleration, LOTUS shows promise for decreasing scan time, which is especially beneficial for diffusion MRI. 2026-02-04T21:52:55Z 31 pages, 8 figures, 3 supplementary figures, submitted to Magnetic Resonance in Medicine Mayuri Sothynathan Paul I. Dubovan Corey. A. Baron http://arxiv.org/abs/2509.05047v2 Object independent scatter sensitivities for PET, applied to scatter estimation through fast Monte Carlo simulation 2026-02-04T13:59:59Z Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit detector physics. Incorporating detector sensitivities for scatter is challenging because scattered events exhibit less constrained properties, such as incidence angles, compared to true coincidences. We integrated a 5D single-photon detection probability lookup table (LUT) accounting for photon energy, incidence angle, and detector location into the simulator logic. The resulting scatter sinogram is scaled by a precomputed, LUT-specific scatter sensitivity sinogram. Scatter was simulated using MCGPU-PET, a fast Monte Carlo (MC) simulator with a simplified scanner model, and applied to phantom data from a simulated GE Signa PET/MR in GATE. We evaluated three scenarios: (1) high-count MC simulations from a known activity distribution; (2) limited-count simulations; and (3) joint estimation of activity and scatter under low-count conditions. The method was also tested on two real Signa PET/MR acquisitions. In scenario 1, scatter-compensated reconstructions achieved <1% global bias in all active regions. In scenario 2, noisy scatter estimates caused positive bias, but Gaussian smoothing restored accuracy to scenario 1 levels. In scenario 3, joint estimation maintained <1% bias in nearly all regions. For real scans, the MC-based scatter estimate closely matched the vendor-provided scatter estimate. This proof-of-concept demonstrates that scatter sensitivity modeling can enhance simulators by incorporating detector physics. It supports the feasibility of using fast MC simulations for real scans, offering improved accuracy and robustness to acquisition noise in clinical PET reconstruction. 2025-09-05T12:23:45Z 23 pages, 14 figures, accepted and published by Physics in Medicine and Biology Physics in Medicine Biology, vol. 71, p. 025020, jan 2026 Simon Noë KU Leuven Seyed Amir Zaman Pour KU Leuven Ahmadreza Rezaei KU Leuven Charles Stearns GE HealthCare Johan Nuyts KU Leuven Georg Schramm KU Leuven 10.1088/1361-6560/ae3a31 http://arxiv.org/abs/2511.16465v5 Mesoscale tissue properties and electric fields in brain stimulation: Bridging the macroscopic and microscopic scales using layer-specific cortical conductivity 2026-02-04T13:31:47Z Accurate simulations of electric fields (E-fields) in neural stimulation depend on tissue conductivity representations that link underlying microscopic tissue structure with macroscopic assumptions. Mesoscale conductivity variations can produce meaningful changes in E-fields and neural activation thresholds but remain largely absent from standard macroscopic models. Conductivity variations within the cortex are expected given the differences in cell density and volume fraction across layers. We review recent efforts modeling microscopic and mesoscopic E-fields and outline approaches that bridge micro- and macroscales to derive consistent mesoscale conductivity distributions. Using simplified microscopic models, effective tissue conductivity was estimated as a function of volume fraction of extracellular space, and the conductivities of different cortical layers were interpolated based on experimental volume fraction. The effective tissue conductivities were monotonically decreasing convex functions of the cell volume fraction. With decreasing cell volume fraction, the conductivity of cortical layers increased with depth from layer 2 to 6. Although the variation of conductivity within the cortex was small when compared to the conductivity of extracellular fluid (9% to 15%), the conductivity difference was considerably larger when compared between layers, e.g., with layer 3 and 6 being 20% and 50% more conductive than layer 2, respectively. The review and analysis provide a foundation for accurate multiscale models of E-fields and neural stimulation. Using layer-specific conductivity values within the cortex could improve the accuracy of estimations of thresholds and distributions of neural activation in E-field models of brain stimulation. 2025-11-20T15:29:43Z 20 pages, 6 figures, 4 tables Boshuo Wang Torge H. Worbs Minhaj A. Hussain Aman S. Aberra Axel Thielscher Warren M. Grill Angel V. Peterchev http://arxiv.org/abs/2602.04461v1 Human-organ-scale x-ray fluorescence ghost imaging for radioisotope-free diagnostics 2026-02-04T11:45:44Z A wide range of diagnostic information in medicine is currently obtained using radioactive tracers. While central to nuclear medicine, these methods are inherently constrained: radiation dose limits repeat examinations, short tracer half-lives and complex logistics restrict access and raise costs, and their relatively poor spatial resolution often necessitates complementary CT or MRI. Here we present a first proof-of-concept demonstration of a non-radioactive alternative based on x-ray fluorescence (XRF) computational ghost imaging (CGI) at the human-organ scale. Using a thyroid phantom filled with iodine solution as a model system, we show that structured illuminations combined with fluorescence detection reconstruct the iodine distribution with high fidelity. This approach eliminates the need for radioactive tracers while preserving image quality, and in principle can reach spatial resolution comparable to CT. Beyond this demonstration, XRF-CGI establishes a generalizable framework for non-radioactive tracer imaging, opening a route toward safer, repeatable, and more accessible diagnostics. 2026-02-04T11:45:44Z 5 figures, 13 pages E. Levinson R. H. Shukrun N. Vigano S. Shwartz