https://arxiv.org/api/ZQVUFO+rZ9eKWlmY95CQxhpx0cw 2026-06-21T16:17:28Z 8985 180 15 http://arxiv.org/abs/2604.24417v1 Potential pof laser-driven VHEEs towards FLASH radiotherapy: Monte Carlo dosimetric study of single-field pencil beam scanning of a brain tumor 2026-04-27T12:47:52Z Radiotherapy with Very High Energy Electron (VHEE) beams is being extensively investigated for the treatment of deep-seated tumours, even in view of novel protocols based on the so-called FLASH effect. Laser WakeField Acceleration (LWFA) provides a compact and affordable accelerator technology for VHEE electron beams, featuring ultra-high instantaneous dose rates and holding the promise to provide Ultra-High (average) Dose Rates (UHDRs) needed to activate the FLASH effect, with major efforts ongoing worldwide to fulfill this promise. Therapeutic doses are already at reach, using pencil beams produced via LWFA. These beams typically exhibit significant energy spread, and small transverse size. These features are rather different from those of other beams considered so far in radiotherapy studies. In view of a rapid clinical translation of LWFA-VHEE beams it is therefore of paramount importance to assess the role of these properties in the dose delivery to the patient. Here we present a study carried out via start-to-end (PIC and Monte Carlo) simulations, of the main dosimetric features of a realistic laser-driven VHEE pencil beam targeted on a brain tumor. The entire tumor coverage is achieved by a scanning procedure; the dose pattern resulting from tessellation, i.e. the overlapping of adjacent beamlets, and the role of energy spread are thoroughly discussed. Dose Volume Histograms are presented, and their quality is discussed. The impact of the FLASH effect is also considered, introducing a degree of healthy tissue sparing in the modelling. Finally, the foreseen technological path toward the achievement of FLASH dose rates with LWFA-VHEE beams is briefly outlined. 2026-04-27T12:47:52Z Leonida A. Gizzi Damiano Del Sarto Federico Avella Gabriele Bandini Simona Piccinini Daniele Panetta Davide Terzani Luca Labate http://arxiv.org/abs/2512.04889v2 FENCE: Flexible Electric Noise reduCtion Endo-shield for the Suppression of Electromagnetic Interference in Low-Field MRI 2026-04-27T08:25:37Z Electromagnetic interference (EMI) is a significant challenge for low-field MRI systems operating without conventional Faraday-shielded rooms. Traditional EMI mitigation approaches include external shields, subject grounding via electrodes, or active noise cancellation requiring synchronized receive channels. These methods either limit portability, introduce patient discomfort, or demand advanced hardware. In this work, we start from the hypothesis that EMI primarily couples capacitively from the body to the RF coil. We investigated two methods of blocking capacitive coupling while preserving inductive MRI signal detection: First, we employed capacitive segmentation of the RF coil and studied its effect on EMI coupling. Second, we present FENCE (Flexible Electromagnetic Noise reduCtion Endo-shield), a novel approach blocking capacitive coupling using flexible PCB shields placed inside the RF coil. FENCE can be retrofitted to existing RF coils. Finite element (FE) simulations were used to estimate the expected shielding performance and the impact on RF coil losses prior to practical implementation. Testing in various realistic scenarios then demonstrated that the combination of FENCE with segmented solenoid coils is effective against both environmental noise sources and controlled EMI. In phantom experiments, FENCE significantly improved imaging performance and reduced EMI levels to near-baseline levels with 9% reduction in coil quality factor (Q factor), showing good agreement with the predictions from the FE simulations. In-vivo head imaging confirmed these results across diverse electromagnetic environments significantly improving imaging performance while showing an ~18% decrease in Q factor. FENCE provides a simple method for EMI mitigation in low-field MRI, enhancing image quality while maintaining system portability and accessibility. 2025-12-04T15:15:47Z 21 pages, 13 figures, 8 tables NMR in Biomedicine 2026;39:e70287 Julia Pfitzer Martin Uecker Hermann Scharfetter 10.1002/nbm.70287 http://arxiv.org/abs/2601.12645v3 Radio-frequency pulse design in local rotating frame in magnetic resonance imaging 2026-04-26T18:14:14Z The problem of spatially selective radio-frequency (RF) pulse design in magnetic resonance imaging (MRI) is typically stated in the form of determining, analytically or numerically, RF waveforms to be applied in synchrony with one or more predetermined gradient waveforms. In most cases, the dynamics of the nuclear spin magnetization under the RF and gradient fields is described in a global rotating frame that cancels the effect of the static (main) magnetic field B0. In this work, we consider an alternative frame of reference, which can be called a local rotating frame where total longitudinal magnetic field (B0 plus gradient) in every voxel is zero. In this frame, the effect of time-dependent gradient field is integrated out, and the remaining magnetization dynamics, governed by much weaker RF fields, becomes both simpler and slower. We show that recasting existing RF design methods in such a frame provides useful insights and techniques that are not obvious in the conventional description. The methods we consider include (i) two-dimensional spatial RF pulse design in the excitation k-space, (ii) Shinnar-Le Roux RF design, (iii) residual phase calculation in slice-selective excitation, and (iv) iterative and numerical solutions for multi-coil RF pulse design. In particular, we show that the new formalism can substantially reduce the Bloch simulation time which can greatly benefit iterative pulse designs in parallel transmit. In all, the proposed framework provides considerable theoretical insights and practical utility for RF pulse design in MRI. 2026-01-19T01:35:18Z 6 figures Seung-Kyun Lee http://arxiv.org/abs/2602.09622v2 Inter-Electrode Pulse Wave Velocity: A Direct Method for Maternal Arterial Stiffness Assessment During Pregnancy Using Multi-Channel ECG 2026-04-26T16:51:03Z Objective: To validate a novel inter-electrode pulse wave velocity (PWV) method that measures pulse propagation between ECG electrodes without left ventricular ejection time (LVET) estimation. Methods: We analyzed 43 three-channel ECG recordings (1000 Hz) from the FELICITy 2 cohort (approximately 19 and 35 weeks gestation). R-peaks were independently detected per channel using an ensemble approach. Time lags (Delta t) between matched R-peaks across electrode pairs were used to compute PWV as PWV = L / Delta t, where L is effective inter-electrode distance. Three channel pairs yielded independent PWV estimates. Temporal stability was assessed using sliding windows (1-15 minutes). To test whether Delta t reflects morphology or vascular propagation, we evaluated three QRS fiducials (R-peak, QRS onset, maximum dV/dt) and two bandpass filters (0.5-40 and 0.5-100 Hz). Longitudinal changes were compared between control (n=24) and yoga (n=20) groups. Results: PWV values were physiologically plausible and consistent with aortic PWV (5-10 m/s): control 7.40 +/- 1.51 vs 6.98 +/- 1.63 m/s; yoga 7.10 +/- 2.15 vs 8.16 +/- 0.91 m/s (early vs late pregnancy). PWV stabilized at 5 minutes (coefficient of variation 12.3 percent), with 2.6- to 5.2-fold lower variability than heart rate and heart rate variability. Inter-electrode delays (15-27 ms) persisted across fiducials and were minimally affected by filter settings (change -8.5 percent, not significant), arguing against purely morphological distortion; PWV remained within 6.8-9.1 m/s. Preliminary group trends differed (control -5.7 percent, yoga +14.9 percent; interaction p=0.07). Conclusions: Inter-electrode PWV enables direct spatial assessment of pulse propagation with physiologically valid values, is robust to fiducial and filtering choices, and shows promise for pregnancy-related arterial stiffness assessment with standard multi-channel ECG. 2026-02-10T10:09:15Z A patent was filed by JoyBeat Medical, Inc, for the technology described (US Patent Application No.63/968,116) Nicolas B. Garnier Phys-ENS, INP-CNRS Marlene J. E. Mayer Clara Becker Marta C. Antonelli Silvia M. Lobmaier Martin G Frasch http://arxiv.org/abs/2604.23675v1 GS-DOT: Gaussian splatting-based image reconstruction for diffuse optical tomography 2026-04-26T12:27:38Z This work presents GS-DOT, a novel image reconstruction framework based on Gaussian Splatting (GS) for diffuse optical tomography (DOT). Inspired by GS for rendering applications, absorption coefficients are represented as a sparse sum of anisotropic Gaussian primitives optimized to fit measured time-resolved point-spread functions through analytic gradients and Adam optimization. This is the first adaptation of GS algorithms in the photon diffusion regime, where the ray transport function is replaced by the diffusion functions to enable accurate modeling of light transport in highly scattering media. Validation on synthetic tissue models demonstrate high accuracy in localization and quantification of reconstructed absorption maps for both clean and noisy signals. GS-DOT has demonstrated high robustness to noise and showed a huge reduction in memory demand. 2026-04-26T12:27:38Z Jingjing Jiang http://arxiv.org/abs/2605.00881v1 A Coupled Fourth Order Telegraph Diffusion Framework Using Grayscale Indicators for Image Despeckling 2026-04-26T09:44:37Z Speckle noise severely limits the quality of images acquired from coherent imaging systems such as Synthetic Aperture Radar (SAR) and medical ultrasound. Traditional second-order PDE-based despeckling approaches, although popular, often introduce staircase artifacts and blur fine details. To overcome these limitations, we present a nonlinear, fourth-order coupled hyperbolic-parabolic PDE model that effectively reduces noise while preserving the structure. The framework consists of two evolution equations: one governing fourth-order diffusion for effective speckle reduction and smooth intensity transitions, and another refining an edge indicator to protect textures and structural features. The diffusion coefficient is adaptively constructed using both the image intensity variable u and a grayscale-based indicator function, ensuring structure-aware denoising while avoiding blocky artifacts and preserving fine details. We also prove the existence of a weak solution to the proposed model by applying Schauder fixed-point theorem. A finite-difference scheme with Gauss Seidel iteration is employed for efficient implementation. We compare the proposed model with the existing coupled second-order PDE model (HPCPDE) and the fourth-order telegraph diffusion model (TDFM). The results show that our model consistently outperforms these approaches. Experiments on standard grayscale images, real SAR and ultrasound data, as well as speckle-corrupted color images, demonstrate that the proposed method achieves superior performance over conventional PDE-based techniques in terms of PSNR, MSSIM, and Speckle Index. 2026-04-26T09:44:37Z Manish Kumar Rajendra K. Ray http://arxiv.org/abs/2604.23390v1 Visualising Parker Weighting in Short-Scan Cone-Beam Micro-CT: A Practical Reference 2026-04-25T17:43:29Z Short-scan FDK reconstruction is widely used in preclinical cone-beam micro-CT because it reduces scan time and radiation dose, and because the large volume sizes typical of micro-CT make iterative methods impractical for routine use. Short scans, however, introduce non-uniform data redundancy that must be corrected by Parker weighting to avoid directional shading artefacts. This note provides a visual and quantitative summary of Parker weighting as implemented for the eXplore CT 120 scanner. We illustrate the weight maps in the detector and sinogram domains, demonstrate the shading artefacts that arise without correction on both an image quality phantom and an in vivo mouse lung, and show via MTF, NPS, and detectability analysis that Parker weighting corrects HU inaccuracies without degrading image quality. No new methods are introduced; the aim is to serve as a concise practical reference for groups implementing or evaluating short-scan FDK pipelines. 2026-04-25T17:43:29Z Falk L Wiegmann Nancy L Ford http://arxiv.org/abs/2604.23075v1 Design and Optimization of a Pole-less 0.2 T C-Type MRI Magnet 2026-04-25T00:04:56Z Low-field MRI is increasingly considered accessible for imaging owing to its lower cost, simpler infrastructure requirements, and potential for mobile and point-of-care deployment. A central challenge is achieving clinically useful field strength and homogeneity while keeping the magnet lightweight and maintaining patient accessibility. This work presents the design and magnetostatic simulation of a pole-less, 0.2 T, C-type bipolar magnet comprising two cylindrical N52 permanent magnets and four concentric rings that replace traditional pole pieces to enhance field homogeneity and reduce weight in bipolar magnet designs. Geometric parameters, including each magnet ring thickness, height, angular anchorage, spacing between magnets, and the magnets' vertical offset relative to the horizontal yokes, were manually investigated to improve magnetic field homogeneity in a 20 cm DSV. Simulations were performed in CST Studio Suite, yielding a peak field of 0.2 T, with a peak inhomogeneity of 1.43 mT across the 20 cm DSV and a total weight of 590 kg. A pole piece design with comparable dimensions, used as a benchmark for inhomogeneity and weight, was designed and simulated. It yielded a peak field of 0.15 T and a weight of 890 kg, with a 0.7 mT inhomogeneity over a 20 cm DSV. This study demonstrates the feasibility of replacing the traditional pole pieces with magnet rings to reduce weight while enhancing patient access with the C-magnet structure in yoked MRI systems. 2026-04-25T00:04:56Z 9 pages,5 figures, manuscript Ivan Etoku Oiye Ajay Sharma Sairam Geethanath http://arxiv.org/abs/2604.23063v1 Efficient primal-dual algorithm for imaging applications with matrix stacking, applied to DBT image reconstruction 2026-04-24T23:17:41Z The primal-dual hybrid gradient (PDHG) algorithm for solving convex optimization problems that arise in tomographic imaging is revisited. In particular, simplification of the selection of step-size parameters is developed for optimization problems with multiple terms, each containing a linear transform subject to splitting. This simplification maintains algorithm efficiency while avoiding massive grid searches for the optimal parameter settings. The PDHG framework is demonstrated on an image reconstruction problem for wide-angle digital breast tomosythesis (DBT); use of the proposed optimization problem is enabled by the framework and it is demonstrated to have some advantage in quantitative accuracy of the reconstructed volume and in improving DBT depth resolution. 2026-04-24T23:17:41Z Submitted to Physics in Medicine and Biology for review Emil Y. Sidky John Paul Phillips Zheng Zhang Dan Xia Ingrid S. Reiser Xiaochuan Pan http://arxiv.org/abs/2604.23047v1 Benchmarking Open-Source FDK Against Commercial and Iterative Reconstruction Methods for Preclinical Micro-CBCT 2026-04-24T22:14:46Z Preclinical micro-CT reconstruction involves large projection sizes and volumes that make iterative methods costly - 5x to 50x slower than analytic alternatives on modern GPUs. Whether this cost is justified depends on the imaging task, yet head-to-head comparisons using task-based metrics on identical preclinical data are lacking. We benchmark four reconstruction methods on identical acquisitions from an eXplore CT 120 micro-CT scanner (Trifoil Imaging, USA): an open-source Feldkamp-Davis-Kress (FDK) pipeline, the proprietary vendor software, and two iterative toolboxes at default settings - ASTRA SIRT and TIGRE OS-SART. Using the modulation transfer function (MTF), noise power spectrum (NPS), and non-prewhitening detectability index (NPW d'), we show that single-metric rankings are misleading: the vendor software achieves the highest spatial resolution ($\mathrm{MTF}_{10} = 2.96$ lp/mm) but fails to reach the Rose criterion ($d'=3$) for 100 HU contrast objects on a half-scan acquisition. ASTRA SIRT, at 5x the computation time of FDK, provides the best low-contrast detectability, while TIGRE OS-SART at 50x the cost offers no additional benefit and exhibits instability across scan protocols. For high-contrast tasks, all methods perform comparably. We release our FDK pipeline as open-source software, providing a fast, transparent, and integrable reconstruction tool for the preclinical micro-CT community. 2026-04-24T22:14:46Z Falk L Wiegmann Nancy L Ford http://arxiv.org/abs/2509.17370v3 Non-invasive Reversible Software-based Electron FLASH Irradiation Configuration of a Linear Accelerator in Clinical Use 2026-04-24T22:03:45Z Configuring clinical linear accelerators (linacs) for ultra-high dose rate (UHDR) electron experiments typically requires invasive hardware manipulation and/or irreversible manufacturer modifications, limiting broader implementation. We present an independently developed UHDR electron configuration of a clinical TrueBeam linac that allows reversible switching between preclinical UHDR and conventional (CONV) modes using only non-invasive software settings. UHDR mode was achieved via service mode software with RF and beam current settings typical of a photon beam, the photon target and monitor chamber retracted, and a clinically unused low-energy scattering foil inserted. An external AC current transformer (ACCT) for beam monitoring, anatomy-specific collimator, and sample holder were mounted on the accessory tray, with external ion chamber in solid water for exit dose monitoring. Percent depth dose (PDD) was measured for UHDR and CONV beams. Dose-per-pulse (DPP) was varied by adjusting gun voltage and quantified with radiochromic film at different source-to-surface distances (SSD). Beam profiles assessed dose uniformity and usable field size. Dose calibration was established between film, ACCT, and ion chamber, and day-to-day reproducibility was tested. PDD confirmed similar energies for UHDR (12.8MeV) and CONV (11.9MeV) beams with matching profiles through mouse thickness. Maximum DPP exceeded 0.5Gy, reaching ~1.5Gy for collimated in vivo setups and ~0.7Gy at extended SSD for tissue culture. Field flatness and symmetry were maintained, supporting organ-specific irradiations and up to 5cm fields for culture. Calibration showed strong linearity across detectors, and output variation was <4%. We demonstrated accurate, reproducible UHDR delivery on a widely available clinical linac with no invasive hardware manipulation, enabling preclinical FLASH research on a clinical treatment machine. 2025-09-22T05:36:17Z 14 pages, 4 figures, 1 table Stavros Melemenidis Dixin Chen Cody Jensen Joseph B. Schulz Murat Surucu Amy S. Yu Edward E. Graves Mengying Shi Peter G. Maxim Andrew Currell Billy W. Loo Lawrie Skinner M. Ramish Ashraf http://arxiv.org/abs/2604.22907v1 Fingertip Micro-Motion as a Source of Respiratory Information During Sleep Using Triaxial Accelerometers 2026-04-24T17:02:22Z Objective: Triaxial accelerometers (TAAs) are widely used in homecare medicine. This study investigates whether TAA signals recorded at the fingertip encode respiratory information, particularly instantaneous respiratory rate (IRR) and respiratory effort, during sleep. Method: We propose an antiderivative-based nonlinear transformation to convert TAA signals into a respiratory surrogate, termed TAA-resp. To quantify the embedded respiratory-induced motion, a modern time-frequency analysis tool is applied to derive an index, referred to as the respiratory motion index (RMI). The proposed TAA-resp and RMI are validated on a dataset comprising 39 full-night recordings with simultaneous polysomnography (PSG) and a fingertip TAA measurements. Criteria for labeling TAA-resp signal quality as good, moderate, or poor are established, and expert annotations are obtained. Result: On average, TAA-resp over 22.2% $\pm$ 15.6% of full-night recordings encodes high-quality respiratory information, reaching up to 58.9% in some cases. TAA-resp shows stronger correlation with thoracic and abdominal motion than with airflow, indicating predominant capture of respiratory effort. High-quality TAA-resp offers an accurate IRR estimate with root mean square error $0.027 \pm 0.022$ Hz. RMI is higher for high-quality segments and lower for poor-quality segments, and its distribution aligns with physiology, with higher values during REM, N2, and N3 sleep and in the absence of apnea or hypopnea events. In leave-one-subject-out cross-validation, RMI predicts quality labels with 0.74 sensitivity and 0.75 specificity. Conclusion: Fingertip-mounted TAAs encode meaningful respiratory information. Leveraging this underutilized signal may enhance home-based sleep monitoring in channel-limited settings. 2026-04-24T17:02:22Z Jeanne Lin Lily Liu Hau-Tieng Wu http://arxiv.org/abs/2604.22713v1 OpenMRF: A Modular, Vendor-Neutral Open-Source Framework for Reproducible Magnetic Resonance Fingerprinting using Pulseq 2026-04-24T16:54:43Z Purpose: Widespread adoption and methodological advancement of Magnetic Resonance Fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open-source tools. To address these barriers, we introduce OpenMRF - a comprehensive Pulseq-based solution - designed to enable consistent, reproducible, and transferable MRF research across vendors, sites, and field strengths. Methods: OpenMRF integrates modular Pulseq-based sequence design, Bloch-simulation-based dictionary creation directly from .seq files, and iterative low-rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi-site ISMRM/NIST phantom study on Siemens MRI systems at 0.55 T, 1.5 T, and 3 T as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T). Results: Simulations demonstrated high mapping accuracy in an ISMRM/NIST-like digital phantom, with low-rank reconstruction yielding deviations of 0.03+/-0.32 % (T1) and 0.12+/-1.94 % (T2). The multi-site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of -0.1+/-2.9 % (T1), -1.5+/-8.7 % (T2), and -4.0+/-7.2 % (T1rho). In vivo acquisitions produced high-quality parameter maps across platforms and field strengths. Conclusion: OpenMRF provides a robust, open-source, end-to-end Pulseq-based solution for MRF that enables reproducible sequence implementation, physics-accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and multi-site validation, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community. 2026-04-24T16:54:43Z Tom Griesler Jannik Stebani Sydney Kaplan Ivaylo Angelov Petra Albert Martin Blaimer Tobias Wech Xiang Wang Qingping Chen Maxim Zaitsev Zhibo Zhu Qi Liu Peter Martin Jon-Fredrik Nielsen Jesse I Hamilton Peter Nordbeck Nicole Seiberlich Maximilian Gram http://arxiv.org/abs/2604.22666v1 A CMUT-Based Transcranial Focused Ultrasound Platform for Blood-Brain Barrier Opening in Small Animal Models 2026-04-24T15:43:56Z Drug delivery to the brain is limited by the blood-brain barrier (BBB). We developed a capacitive micromachined ultrasonic transducer (CMUT)-based transcranial focused ultrasound system capable of both delivering therapy via BBB opening and monitoring microbubble activity across a broad frequency range. The performance of the geometrically focused half-ring array consisting of five transmitters and one receiving element was first assessed through simulations and in-vitro acoustic measurements with microbubbles. Use of phase-inversion (PI) during transmission effectively suppressed CMUT-generated harmonics and enhanced broadband detection of microbubble emissions. In rats, the same system achieved spatially localized BBB opening, confirmed by T1-weighted magnetic resonance imaging. BBB permeability mapping using dynamic contrast-enhanced magnetic resonance imaging (Ktrans) scaled with pressure. Time-resolved acoustic spectra captured microbubble arrival and decay kinetics, and 7-20dB enhancement in the effective dynamic range is observed with PI processing of acoustic emission signals. Together, these findings establish an integrated CMUT platform for combined therapeutic and sensing applications for BBB opening in small animal models, providing a foundation for future real-time, frequency-agile, closed-loop control of ultrasound-mediated drug delivery to the brain. 2026-04-24T15:43:56Z Sait Kilinc Reza Pakdaman Zangabad Victor Menezes Hohyun Lee Costas Arvanitis Levent Degertekin http://arxiv.org/abs/2604.22457v1 Cross Fusion and Correlation Beamformer for Row-Column Array Based 3D Ultrasound Imaging 2026-04-24T11:22:31Z Row column addressed (RCA) transducers present a promising solution for ultrafast volumetric imaging with a reduced channel count and a large field of view. However, RCA-based 3D imaging is fundamentally limited by severe sidelobe artifacts and a low signal-to-noise ratio (SNR), primarily due to weak transmit focusing inherent in RCA based ultrafast imaging strategies. To overcome these challenges, we propose a cross fusion and correlation (CFAC) method that leverages the incoherence of sidelobe artifacts and noise across datasets acquired using orthogonal apertures and multiple steering angle sets. The performance of the proposed method was validated through simulations, in vitro imaging of a multi-purpose ultrasound phantom, and in vivo experiments, and benchmarked against four established techniques: orthogonal plane wave (OPW) imaging, XDoppler method, row-column-specific frame-multiply-and-sum beamforming (RC-FMAS), and coherent factor (CF) imaging. Simulation results demonstrated that CFAC reduced sidelobe levels by 42.0 dB, 38.9 dB, 28.3 dB, and 25.5 dB compared to OPW, XDoppler, RC-FMAS, and CF, respectively. In phantom experiments, CFAC improved the CNR by up to 17.5 dB. Furthermore, in vivo imaging of a rat kidney showed that CFAC enables visualization of a significantly more detailed microvascular network, achieving a CNR improvement of over 25 dB against all benchmarked methods. In conclusion, the proposed CFAC method effectively suppresses sidelobe artifacts and noise in RCA-based imaging under low-SNR conditions, enabling high-contrast 3D visualization while preserving the high frame rate capabilities of ultrafast ultrasound imaging. 2026-04-24T11:22:31Z Qiandong Sun Rui He Shilin Hou Jiyan Dai Kailiang Xu